Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Med Trop (Mars) ; 41(5): 531-4, 1981.
Artículo en Francés | MEDLINE | ID: mdl-7321847

RESUMEN

The Haik fornix conjonctival flap has been described before the second world war, in order to protect cornea with conjonctiva without cutting the latter as in the classic conjonctival flap. This operation requires only a limited number of instruments and no special ophtalmologic training for the operator. The main indications are: -- keratitis caused by lagophtalmia; -- neurophtalmic keratitis; -- ulcerous keratitis and specially the meta-herpetic ones; -- necessity of a protection before a sanitary evacuation in penetrating wounds of the ocular globe.


Asunto(s)
Conjuntiva/cirugía , Conjuntiva/patología , Humanos , Queratitis/cirugía , Métodos , Colgajos Quirúrgicos
3.
Kidney Int ; 57(6): 2511-8, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10844620

RESUMEN

BACKGROUND: Only few noninvasive methods have the potential to quantitate renal blood flow (RBF) in humans. Positron emission tomography (PET) is a clinical imaging method that can be used to measure the tissue blood flow noninvasively. The purpose of this study was to validate PET measurement of RBF using 15O-labeled water (H215O), a tracer that allows repeated measurements at short time intervals. METHODS: RBF was measured in six pigs by PET and by radioactive microspheres (MS). Three measurements were performed in each pig at baseline (BL), during vascular expansion and dopamine infusion (DA; 20 microg. kg-1. min-1 intravenously), and during angiotensin II (Ang II) infusion (50 ng. kg-1. min-1 intravenously). RBF was estimated from aortic and renal tracer kinetics using a model adapted from the blood flow model described by Kety and Smith. RESULTS: PET and MS values correlated strongly (y = 0.79x + 42, r = 0.93, P < 0.0001) over the RBF range from 100 to 500 mL. min-1. 100 g-1. Pharmacologically induced changes were significant and were measured equally well by PET and MS: 38 and 39%, respectively, below BL (P < 0.005 and P < 0.05) under Ang II, and 47 and 48%, respectively, above BL (P < 0.005 and P < 0.01) under DA. A Bland and Altman representation showed a low average difference of -17 +/- 45 mL. min-1. 100 g-1 (mean +/- SD). CONCLUSION: To our knowledge, this study provides the first validation of RBF measurement by PET using H215O over a large range of RBF values (100 to 500 mL. min-1. 100 g-1), which correspond to RBF values in both healthy subjects and in patients suffering from chronic renal failure.


Asunto(s)
Riñón/diagnóstico por imagen , Circulación Renal , Tomografía Computarizada de Emisión , Animales , Estudios de Evaluación como Asunto , Microesferas , Radioisótopos de Oxígeno , Porcinos , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA