Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Vet Anaesth Analg ; 45(4): 539-544, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29804882

RESUMEN

OBJECTIVE: To compare the induction and recovery characteristics and selected cardiopulmonary variables of midazolam-alfaxalone or midazolam-ketamine in donkeys sedated with xylazine. STUDY DESIGN: Randomized, blinded, crossover experimental trial. ANIMALS: A group of seven adult male castrated donkeys weighing 164 ± 14 kg. METHODS: Donkeys were randomly administered midazolam (0.05 mg kg-1) and alfaxalone (1 mg kg-1) or midazolam (0.05 mg kg-1) and ketamine (2.2 mg kg-1) intravenously following sedation with xylazine, with ≥ 7 days between treatments. Donkeys were not endotracheally intubated and breathed room air. Time to lateral recumbency, first movement, sternal recumbency and standing were recorded. Induction and recovery were assigned scores between 1 (very poor) and 5 (excellent). Heart rate (HR), respiratory rate (fR), invasive arterial blood pressures and arterial blood gases were measured before induction and every 5 minutes following induction until first movement. RESULTS: Time to lateral recumbency (mean ± standard deviation) was shorter after alfaxalone (29 ± 10 seconds) compared with ketamine (51 ± 9 seconds; p = 0.01). Time to first movement was the same between treatments (27 versus 23 minutes). Time to standing was longer with alfaxalone (58 ± 15 minutes) compared with ketamine (33 ± 8 minutes; p = 0.01). Recovery score [median (range)] was of lower quality with alfaxalone [3 (2-5)] compared with ketamine [5 (3-5); p = 0.03]. There were no differences in HR, fR or arterial pressures between treatments. No clinically important differences in blood gases were identified between treatments. Five of seven donkeys administered alfaxalone became hypoxemic (PaO2 <60 mmHg; 8.0 kPa) and all donkeys administered ketamine became hypoxemic (p = 0.13). CONCLUSIONS AND CLINICAL RELEVANCE: Both midazolam-alfaxalone and midazolam-ketamine produced acceptable anesthetic induction and recovery in donkeys after xylazine sedation. Hypoxemia occurred with both treatments.


Asunto(s)
Anestesia Intravenosa/veterinaria , Anestésicos Combinados/administración & dosificación , Anestésicos Intravenosos/administración & dosificación , Sedación Consciente/veterinaria , Equidae , Hipnóticos y Sedantes , Ketamina/administración & dosificación , Midazolam/administración & dosificación , Pregnanodionas/administración & dosificación , Xilazina , Periodo de Recuperación de la Anestesia , Anestesia Intravenosa/métodos , Animales , Análisis de los Gases de la Sangre/veterinaria , Presión Sanguínea/efectos de los fármacos , Sedación Consciente/métodos , Estudios Cruzados , Frecuencia Cardíaca/efectos de los fármacos , Masculino , Frecuencia Respiratoria/efectos de los fármacos
2.
Inhal Toxicol ; 27(2): 113-9, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25600221

RESUMEN

CONTEXT: Exposure to ozone has acute respiratory effects, but few human clinical studies have evaluated cardiovascular effects. OBJECTIVE: We hypothesized that ozone exposure alters pulmonary and systemic vascular function, and cardiac function, with more pronounced effects in subjects with impaired antioxidant defense from deletion of the glutathione-S-transferase M1 gene (GSTM1 null). METHODS: Twenty-four young, healthy never-smoker subjects (12 GSTM1 null) inhaled filtered air, 100 ppb ozone and 200 ppb ozone for 3 h, with intermittent exercise, in a double-blind, randomized, crossover fashion. Exposures were separated by at least 2 weeks. Vital signs, spirometry, arterial and venous blood nitrite levels, impedance cardiography, peripheral arterial tonometry, estimation of pulmonary capillary blood volume (Vc), and blood microparticles and platelet activation were measured at baseline and during 4 h after each exposure. RESULTS: Ozone inhalation decreased lung function immediately after exposure (mean ± standard error change in FEV1, air: -0.03 ± 0.04 L; 200 ppb ozone: -0.30 ± 0.07 L; p < 0.001). The immediate post-exposure increase in blood pressure, caused by the final 15-min exercise period, was blunted by 200 ppb ozone exposure (mean ± standard error change for air: 16.7 ± 2.6 mmHg; 100 ppb ozone: 14.5 ± 2.4 mmHg; 200 ppb ozone: 8.5 ± 2.5 mmHg; p = 0.02). We found no consistent effects of ozone on any other measure of cardiac or vascular function. All results were independent of the GSTM1 genotype. CONCLUSIONS: We did not find convincing evidence for early acute adverse cardiovascular consequences of ozone exposure in young healthy adults. The ozone-associated blunting of the blood pressure response to exercise is of unclear clinical significance.


Asunto(s)
Presión Sanguínea , Sistema Cardiovascular/efectos de los fármacos , Eliminación de Gen , Glutatión Transferasa/genética , Ozono/administración & dosificación , Ozono/efectos adversos , Adolescente , Adulto , Filtros de Aire , Antioxidantes/administración & dosificación , Estudios Cruzados , Método Doble Ciego , Ejercicio Físico , Femenino , Genotipo , Glutatión Transferasa/metabolismo , Voluntarios Sanos , Humanos , Pulmón/efectos de los fármacos , Pulmón/metabolismo , Masculino , Nitritos/sangre , Activación Plaquetaria/efectos de los fármacos , Espirometría , Pruebas de Toxicidad Aguda , Adulto Joven
3.
Part Fibre Toxicol ; 11: 31, 2014 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-25028096

RESUMEN

BACKGROUND: Diabetes may confer an increased risk for the cardiovascular health effects of particulate air pollution, but few human clinical studies of air pollution have included people with diabetes. Ultrafine particles (UFP, ≤100 nm in diameter) have been hypothesized to be an important component of particulate air pollution with regard to cardiovascular health effects. METHODS: 17 never-smoker subjects 30-60 years of age, with stable type 2 diabetes but otherwise healthy, inhaled either filtered air (0-10 particles/cm3) or elemental carbon UFP (~107 particles/cm3, ~50 ug/m3, count median diameter 32 nm) by mouthpiece, for 2 hours at rest, in a double-blind, randomized, crossover study design. A digital 12-lead electrocardiogram (ECG) was recorded continuously for 48 hours, beginning 1 hour prior to exposure. RESULTS: Analysis of 5-minute segments of the ECG during quiet rest showed reduced high-frequency heart rate variability with UFP relative to air exposure (p = 0.014), paralleled by non-significant reductions in time-domain heart rate variability parameters. In the analysis of longer durations of the ECG, we found that UFP exposure increased the heart rate relative to air exposure. During the 21- to 45-hour interval after exposure, the average heart rate increased approximately 8 beats per minute with UFP, compared to 5 beats per minute with air (p = 0.045). There were no UFP effects on cardiac rhythm or repolarization. CONCLUSIONS: Inhalation of elemental carbon ultrafine particles alters heart rate and heart rate variability in people with type 2 diabetes. Our findings suggest that effects may occur and persist hours after a single 2-hour exposure.


Asunto(s)
Carbono/efectos adversos , Diabetes Mellitus Tipo 2/fisiopatología , Frecuencia Cardíaca/efectos de los fármacos , Corazón/efectos de los fármacos , Exposición por Inhalación/efectos adversos , Material Particulado/efectos adversos , Adulto , Estudios Cruzados , Diabetes Mellitus Tipo 2/diagnóstico , Método Doble Ciego , Electrocardiografía , Femenino , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Minnesota , Tamaño de la Partícula , Medición de Riesgo , Factores de Tiempo
4.
Inhal Toxicol ; 24(12): 831-8, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23033996

RESUMEN

Exposure to air pollution is associated with increased morbidity and mortality from cardiovascular disease. We hypothesized that increases in exposure to ambient air pollution are associated with platelet activation and formation of circulating tissue factor-expressing microparticles. We studied 19 subjects with type 2 diabetes, without clinical evidence of cardiovascular disease, who had previously participated in a human clinical study of exposure to ultrafine particles (UFP). Blood was obtained for measurements of platelet activation following an overnight stay in the Clinical Research Center, prior to each of their two pre-exposure visits. Air pollution and meteorological data, including UFP counts, were analyzed for the 5 days prior to the subjects' arrival at the Clinical Research Center. Contrary to expectations, increases in UFP were associated with decreases in surface expression of platelet activation markers. The number of platelet-leukocyte conjugates decreased by -80 (95% confidence interval (CI) -123 to -37, p = 0.001) on the first lag day (20-44 h prior to the blood draw) and by -85 (CI -139 to -31, p = 0.005) on combined lag days 1 to 5, per interquartile range (IQR) increase in UFP particle number (2482). However, levels of soluble CD40L increased 104 (CI 3 to 205, p = 0.04) pg/ml per IQR increase in UFP on lag day 1, a finding consistent with prior platelet activation. We speculate that, in people with diabetes, exposure to UFP activates circulating platelets within hours of exposure, followed by an increase in soluble CD40L and a rebound reduction in circulating platelet surface markers.


Asunto(s)
Contaminantes Atmosféricos/toxicidad , Enfermedades Cardiovasculares/inducido químicamente , Diabetes Mellitus Tipo 2/sangre , Regulación hacia Abajo/efectos de los fármacos , Exposición a Riesgos Ambientales/efectos adversos , Activación Plaquetaria/efectos de los fármacos , Adulto , Contaminantes Atmosféricos/análisis , Contaminación del Aire/efectos adversos , Biomarcadores/sangre , Plaquetas/efectos de los fármacos , Plaquetas/metabolismo , Ligando de CD40/sangre , Enfermedades Cardiovasculares/complicaciones , Micropartículas Derivadas de Células/efectos de los fármacos , Micropartículas Derivadas de Células/metabolismo , Diabetes Mellitus Tipo 2/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tamaño de la Partícula , Material Particulado/análisis , Material Particulado/toxicidad , Solubilidad , Propiedades de Superficie , Regulación hacia Arriba/efectos de los fármacos
5.
Animals (Basel) ; 11(7)2021 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-34359175

RESUMEN

Doxycycline (DXC) is a broad-spectrum antibacterial antimicrobial administered to horses for the treatment of bacterial infections which may also affect donkeys. Donkeys have a different metabolism than horses, leading to differences in the pharmacokinetics of drugs compared to horses. This study aimed to describe the population pharmacokinetics of DXC in donkeys. Five doses of DXC hyclate (10 mg/kg) were administered via a nasogastric tube, q12 h, to eight non-fasted, healthy, adult jennies. Serum, urine, synovial fluid and endometrium were collected for 72 h following the first administration. Doxycycline concentration was measured by competitive enzyme immunoassay. Serum concentrations versus time data were fitted simultaneously using the stochastic approximation expectation-maximization algorithm for nonlinear mixed effects. A one-compartment model with linear elimination and first-order absorption after intragastric administration, best described the available pharmacokinetic data. Final parameter estimates indicate that DXC has a high volume of distribution (108 L/kg) as well as high absorption (10.3 h-1) in donkeys. However, results suggest that oral DXC at 10 mg/kg q12 h in donkeys would not result in a therapeutic concentration in serum, urine, synovial fluid or endometrium by comparison to the minimum inhibitory concentration of common equine pathogens. Further studies are recommended to identify appropriate dosage and dosing intervals of oral DXC in donkeys.

6.
Simul Healthc ; 13(4): 289-294, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29771812

RESUMEN

INTRODUCTION: During simulation-based education, simulators are subjected to procedures composed of a variety of tasks and processes. Simulators should functionally represent a patient in response to the physical action of these tasks. The aim of this work was to describe a method for determining whether a simulator does or does not have sufficient functional task alignment (FTA) to be used in a simulation. METHODS: Potential performance checklist items were gathered from published arthrocentesis guidelines and aggregated into a performance checklist using Lawshe's method. An expert panel used this performance checklist and an FTA analysis questionnaire to evaluate a simulator's ability to respond to the physical actions required by the performance checklist. RESULTS: Thirteen items, from a pool of 39, were included on the performance checklist. Experts had mixed reviews of the simulator's FTA and its suitability for use in simulation. Unexpectedly, some positive FTA was found for several tasks where the simulator lacked functionality. CONCLUSIONS: By developing a detailed list of specific tasks required to complete a clinical procedure, and surveying experts on the simulator's response to those actions, educators can gain insight into the simulator's clinical accuracy and suitability. Unexpected of positive FTA ratings of function deficits suggest that further revision of the survey method is required.


Asunto(s)
Artrocentesis/educación , Entrenamiento Simulado/organización & administración , Análisis y Desempeño de Tareas , Competencia Clínica , Humanos , Entrenamiento Simulado/normas , Interfaz Usuario-Computador
7.
Environ Health Perspect ; 118(12): 1692-8, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20822968

RESUMEN

BACKGROUND: Diabetes confers an increased risk for cardiovascular effects of airborne particles. OBJECTIVE: We hypothesized that inhalation of elemental carbon ultrafine particles (UFP) would activate blood platelets and vascular endothelium in people with type 2 diabetes. METHODS: In a randomized, double-blind, crossover trial, 19 subjects with type 2 diabetes inhaled filtered air or 50 µg/m³ elemental carbon UFP (count median diameter, 32 nm) by mouthpiece for 2 hr at rest. We repeatedly measured markers of vascular activation, coagulation, and systemic inflammation before and after exposure. RESULTS: Compared with air, particle exposure increased platelet expression of CD40 ligand (CD40L) and the number of platelet-leukocyte conjugates 3.5 hr after exposure. Soluble CD40L decreased with UFP exposure. Plasma von Willebrand factor increased immediately after exposure. There were no effects of particles on plasma tissue factor, coagulation factors VII or IX, or D-dimer. CONCLUSIONS: Inhalation of elemental carbon UFP for 2-hr transiently activated platelets, and possibly the vascular endothelium, in people with type 2 diabetes.


Asunto(s)
Contaminantes Atmosféricos/toxicidad , Vasos Sanguíneos/efectos de los fármacos , Carbono/toxicidad , Coagulantes/toxicidad , Diabetes Mellitus Tipo 2/fisiopatología , Material Particulado/toxicidad , Adulto , Factores de Edad , Ligando de CD40/sangre , Estudios Cruzados , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selectina-P/sangre , Factores Sexuales , Vasculitis Sistémica/inducido químicamente , Adulto Joven , Factor de von Willebrand/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA