Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
World Neurosurg ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38871284

RESUMEN

BACKGROUND: The fusion rate, clinical efficacy, and complications of minimally invasive fusion surgery and open fusion surgery in the treatment of lumbar degenerative disease are still unclear. METHODS: We conducted a literature search using PubMed, Embase, Cochrane Library, CNKI, and WANFANG databases. RESULTS: This study included 38 retrospective studies involving 3,097 patients. Five intervention modalities were considered: unilateral biportal endoscopic-lumbar interbody fusion (UBE-LIF), percutaneous endoscopic-lumbar interbody fusion (PE-LIF), minimally invasive-transforaminal lumbar interbody fusion (MIS-TLIF), transforaminal lumbar interbody fusion (TLIF), and posterior lumbar interbody fusion (PLIF). Quality assessment indicated that each study met acceptable quality standards. PE-LIF demonstrated reduced low back pain (OR=0.50, CI: 0.38-0.65) and lower complication rate (OR=0.46, CI: 0.25-0.87) compared to PLIF. However, in indirect comparisons, PE-LIF showed the lowest fusion rates, with the ranking as follows: UBE-LIF (83.2%) > MIS-TLIF (59.6%) > TLIF (44.3%) > PLIF (39.8%) > PE-LIF (23.1%). With respect to low back pain relief, PE-LIF yielded the best results, with the order of relief as follows: PE-LIF (96.4%) > MIS-TLIF (64.8%) > UBE-LIF (62.6%) > TLIF (23.0%) > PLIF (3.2%). Global and local consistency tests showed satisfactory results, and heterogeneity tests indicated good stability. CONCLUSIONS: Compared to conventional open surgery, minimally invasive fusion surgery offered better scores for low back pain and Oswestry Disability Index, lower complication rates, reduced bleeding, and shorter hospital stays. However, minimally invasive fusion surgery did not show a significant advantage in terms of fusion rate and had a longer operative time.

2.
Orthop Surg ; 11(2): 263-269, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31025808

RESUMEN

OBJECTIVE: To assess the differences in bone mineral density (BMD) and hip geometry in trochanteric and cervical hip fractures in elderly Chinese patients. METHODS: A consecutive series of 196 hip fracture patients aged over 50 years was recruited from November 2013 to October 2015, including 109 cases of cervical fractures (36 males and 73 females) and 87 cases of trochanteric fractures (34 males and 53 females). All patients were evaluated through dual-energy X-ray absorptiometry, and baseline characteristics, BMD and structural parameters were collected and reviewed. RESULTS: There were statistically significant differences in age, height, and body mass index between patients with each type of fracture, and patients with trochanteric fractures were older than those with cervical fractures, especially in women. The BMD in trochanteric fractures was markedly lower than in cervical fractures in all five sites of the hip by an approximate reduction of 10%, in both men and women. The cross-sectional area, cross-sectional moment of inertia, and the cortical thickness in the cervical fracture group were significantly higher than in the trochanteric fracture group. However, the buckling ratio of both the femoral neck and trochanteric region were significantly lower in the cervical fracture group. Age (/10 years), cross-sectional moment of inertia in femoral neck and buckling ratio in trochanteric region were significant risk factors for trochanteric fractures compared with cervical fractures. CONCLUSIONS: Compared with cervical hip fractures, patients with trochanteric fractures were older, had a lower BMD, and had less bone mechanical strength, especially in female patients. Age, femoral neck cross-sectional moment of inertia (FNCSMI), and trochanteric region buckling ratio (ITBR) were stronger risk factors for trochanteric hip fractures than for cervical fractures.


Asunto(s)
Fracturas de Cadera/patología , Huesos Pélvicos/patología , Absorciometría de Fotón , Factores de Edad , Anciano , Densidad Ósea , Femenino , Fracturas de Cadera/etiología , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo
3.
Neural Regen Res ; 11(6): 963-70, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27482226

RESUMEN

Previous studies of animal models of chronic mechanical compression of the spinal cord have mainly focused on cervical and thoracic lesions, but few studies have investigated thoracolumbar injury. The specific pathophysiological mechanism of chronic thoracolumbar cord injury has not yet been elucidated. The purpose of this study was to improve animal models of chronic thoracolumbar cord compression using the progressive screw. A custom-designed flat plastic screw was implanted in the spinal cord between thoracic vertebrae 12 and lumbar 1 of rats. The screw was tightened one complete turn (0.5 mm) every 7 days for 4 weeks to create different levels of chronic spinal cord compression. Following insertion of the screw, there was a significant decline in motor function of the hind limbs, and severe stenosis of micro-computed tomography parameters in the spinal cord. Cortical somatosensory evoked potential amplitudes were reduced remarkably, and latencies were prolonged at 30 minutes after surgery. The loss of motor neurons in the gray matter was marked. Demyelination and cavitation were observed in the white matter. An appropriate rat model of chronic thoracolumbar cord compression was successfully created using the progressive screw compression method, which simulated spinal cord compression injury.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA