Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circ Res ; 106(1): 145-54, 2010 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-19875725

RESUMEN

RATIONALE: S100A12 is a small calcium binding protein that is a ligand of RAGE (receptor for advanced glycation end products). RAGE has been extensively implicated in inflammatory states such as atherosclerosis, but the role of S100A12 as its ligand is less clear. OBJECTIVE: To test the role of S100A12 in vascular inflammation, we generated and analyzed mice expressing human S100A12 in vascular smooth muscle under control of the smooth muscle 22alpha promoter because S100A12 is not present in mice. METHODS AND RESULTS: Transgenic mice displayed pathological vascular remodeling with aberrant thickening of the aortic media, disarray of elastic fibers, and increased collagen deposition, together with increased latent matrix metalloproteinase-2 protein and reduction in smooth muscle stress fibers leading to a progressive dilatation of the aorta. In primary aortic smooth muscle cell cultures, we found that S100A12 mediates increased interleukin-6 production, activation of transforming growth factor beta pathways and increased metabolic activity with enhanced oxidative stress. To correlate our findings to human aortic aneurysmal disease, we examined S100A12 expression in aortic tissue from patients with thoracic aortic aneurysm and found increased S100A12 expression in vascular smooth muscle cells. CONCLUSIONS: S100A12 expression is sufficient to activate pathogenic pathways through the modulation of oxidative stress, inflammation and vascular remodeling in vivo.


Asunto(s)
Aneurisma de la Aorta/metabolismo , Músculo Liso Vascular/metabolismo , Estrés Oxidativo , Proteínas S100/biosíntesis , Vasculitis/metabolismo , Animales , Aneurisma de la Aorta/genética , Aneurisma de la Aorta/patología , Células Cultivadas , Colágeno/biosíntesis , Colágeno/genética , Tejido Elástico/metabolismo , Tejido Elástico/patología , Humanos , Interleucina-6/genética , Interleucina-6/metabolismo , Ratones , Ratones Transgénicos , Músculo Liso Vascular/patología , Receptor para Productos Finales de Glicación Avanzada , Receptores Inmunológicos/agonistas , Receptores Inmunológicos/genética , Receptores Inmunológicos/metabolismo , Proteínas S100/genética , Proteína S100A12 , Fibras de Estrés/genética , Fibras de Estrés/metabolismo , Factor de Crecimiento Transformador beta/genética , Factor de Crecimiento Transformador beta/metabolismo , Vasculitis/genética , Vasculitis/mortalidad
2.
J Comput Assist Tomogr ; 36(4): 443-9, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22805675

RESUMEN

OBJECTIVE: The ability of multidetector computed tomography (MDCT) to detect stress-induced myocardial perfusion abnormalities is of great clinical interest as a potential tool for the combined evaluation of coronary stenosis and its hemodynamic significance. We tested the hypothesis that quantitative 3-dimensional (3D) analysis of myocardial perfusion from MDCT images obtained during regadenoson stress would more accurately detect the presence of significant coronary artery disease (CAD) than identical analysis when performed on resting MDCT images. METHODS: We prospectively studied 50 consecutive patients referred for CT coronary angiography (CTCA) who agreed to undergo additional imaging with regadenoson (0.4 mg; Astellas). Images were acquired using prospective gating (256-channel; Philips). Custom analysis software was used to define 3D myocardial segments, and calculate for each segment an index of severity and extent of perfusion abnormality, Qh, which was compared with perfusion defects predicted by the presence and severity of coronary stenosis on CTCA. RESULTS: Three patients were excluded because of image artifacts. In the remaining 47 patients, CTCA depicted stenosis more than 50% in 23 patients in 37 of 141 coronary arteries. In segments supplied by the obstructed arteries, myocardial attenuation was slightly reduced compared with normally perfused segments at rest (mean [SD], 91 [21] vs 93 [26] Hounsfield units, not significant) and, to a larger extent, at peak stress (102 [21] vs 112 [20] Hounsfield units, P < 0.05). In contrast, index Qh was significantly increased at rest (0.40 [0.48] vs 0.26 [0.41], P < 0.05) and reached a nearly 3-fold difference at peak stress (0.66 [0.74] vs 0.28 [0.51], P < 0.05). The addition of regadenoson improved the diagnosis of CAD, as reflected by an increase in sensitivity (from 0.57 to 0.91) and improvement in accuracy (from 0.65 to 0.77). CONCLUSIONS: Quantitative 3D analysis of MDCT images allows objective detection of CAD, the accuracy of which is improved by regadenoson stress.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Imagenología Tridimensional/métodos , Tomografía Computarizada Multidetector/métodos , Antagonistas del Receptor de Adenosina A2 , Estenosis Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Purinas , Pirazoles , Curva ROC , Sensibilidad y Especificidad , Programas Informáticos
3.
Eur Radiol ; 20(2): 337-47, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19711083

RESUMEN

BACKGROUND: Although the ability of multi-detector computed tomography (MDCT) to detect perfusion abnormalities associated with acute and chronic myocardial infarction (MI) has been demonstrated, this methodology is based on visual interpretation of selected 2D slices. OBJECTIVES: We sought to develop a new technique for quantitative volumetric analysis of myocardial perfusion from 3D datasets and test it against resting nuclear myocardial perfusion imaging (NMPI) reference. METHODS: We studied 44 patients undergoing CTCA: a control group of 15 patients and a study group of 29 patients. MDCT datasets acquired for CTCA were analyzed using custom software designed to: (1) generate bull's eye display of myocardial perfusion and (2) calculate a quantitative index of extent and severity of perfusion abnormality, Q(H), for 16 volumetric myocardial segments. Visual interpretation of MDCT-derived bull's eyes was compared with rest NMPI scores using kappa statistics of agreement on a coronary territory and patient basis. Quantitative MDCT perfusion data were correlated with rest NMPI summed scores and used for objective detection of perfusion defects. RESULTS: Visual analysis of MDCT-derived bull's eyes accurately detected perfusion defects in agreement with NMPI (kappa = 0.70 by territory; 0.79 by patient). Quantitative data were in good agreement with NMPI, as reflected by: (1) correlation of 0.87 (territory) and 0.84 (patient) between summed Q(H) and NMPI scores, (2) area under ROC curve 0.87 with sensitivity of 0.79-0.92, specificity 0.83-0.91, and accuracy 0.83-0.89 for objective detection of abnormalities. CONCLUSIONS: Our new technique for volumetric analysis of 3D MDCT images allows accurate objective detection of perfusion defects. This perfusion information can be obtained without additional radiation or contrast load, and may aid in elucidating the significance of coronary lesions.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen de Perfusión/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Algoritmos , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Eur Radiol ; 19(8): 1897-905, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19280193

RESUMEN

MDCT-derived myocardial perfusion has not yet been validated against accepted standards. We developed a technique for quantification of myocardial perfusion from MDCT images and studied its diagnostic value against SPECT myocardial perfusion imaging (MPI). Ninety-eight patients were studied. Abnormal perfusion was detected by comparing normalized segmental x-ray attenuation against values obtained in 20 control subjects. Disagreement with resting MPI was investigated in relationship to MDCT image quality, severity of MPI abnormalities, and stress MPI findings. Resting MPI detected mild or worse abnormalities in 20/78 patients. MDCT detected abnormalities in 15/20 patients (sensitivity of 0.75). Most abnormalities missed by MDCT analysis were graded as mild on MPI. Additional abnormalities found in 16/78 patients were not confirmed on resting MPI (specificity of 0.72). However, 8 of these 16 apparently false positive MDCT perfusion tests had abnormal stress MPI; of these 8 patients, 7 had optimal MDCT image quality, while in 6/8 remaining patients, image quality was suboptimal. When compared with resting MPI, MDCT detected perfusion abnormalities with high accuracy. Moreover, half of MDCT perfusion abnormalities not confirmed by resting MPI were associated with abnormal stress MPI. Importantly, this information can be obtained without additional radiation dose or contrast agent.


Asunto(s)
Isquemia Miocárdica/diagnóstico por imagen , Imagen de Perfusión/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Eur J Echocardiogr ; 10(4): 543-8, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19179363

RESUMEN

AIMS: Intracardiac echocardiography (ICE) and two-dimensional transoesophageal echocardiography (2D TEE) are used in most centres for guiding transcatheter atrial septal defect (ASD) closure. ASDs have complex shapes that are not well characterized with 2D imaging. Real-time 3D TEE (RT3D TEE) provides en-face visualization of the ASD, allowing precise assessment of ASD dimensions. Accordingly, our aims were (i) to determine the feasibility of RT3D TEE to guide ASD closure and (ii) to compare ASD and balloon dimensions (BDs) using RT3D TEE vs. ICE and 2D TEE. METHODS AND RESULTS: Thirteen patients with ostium secundum ASD underwent transcatheter ASD closure. 2D TEE, RT3D TEE, and ICE images were acquired sequentially. RT3D TEE was feasible in all patients. Comparing RT3D TEE and 2D imaging, the mean difference in long-axis dimension was +0.5 mm (P= NS for both), and -1.4 mm in short-axis (2D TEE, P < 0.05; ICE, P = 0.06). BD was greater with 3D TEE vs. ICE (+0.9 mm). CONCLUSION: RT3D TEE can be used to guide transcatheter ASD closure with the advantages of lower cost than ICE, and ability to visualize en-face views of the ASD. ASD and BD as measured by RT3D TEE differ when compared with 2D imaging.


Asunto(s)
Cateterismo/métodos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Defectos del Tabique Interatrial/diagnóstico por imagen , Adolescente , Adulto , Cateterismo Cardíaco/métodos , Niño , Ecocardiografía Doppler en Color , Estudios de Factibilidad , Fluoroscopía , Defectos del Tabique Interatrial/terapia , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Ultrasonografía Intervencional , Adulto Joven
6.
Echocardiography ; 25(6): 584-90, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18652005

RESUMEN

BACKGROUND: Transthoracic echocardiography (TTE) is ordered frequently in patients with suspected pulmonary embolism (PE). Multiple indices have been suggested to play a useful diagnostic role. We sought to determine the relative predictive accuracy of suggested quantitative indices among patients referred for CT scanning for exclusion of PE. METHODS: We retrospectively identified 67 consecutive patients who underwent CT for the exclusion of PE, and had a TTE within 48 hours of CT. Echo indices suggested to play a role in the diagnosis of PE were measured RV/LV area ratio, RV/LV end diastolic dimension ratio, the "McConnell" sign, interventricular septal shift ("D-sign"), Pulmonary artery diameter, tricuspid regurgitation velocity, and "60/60 sign" (TR velocity < 3.9 m/sec plus pulmonary artery acceleration time < 60 msec). RESULTS: CT confirmed PE in 41 (61%). Mean age was 58 (18-92). Forty-five were female. Subjects with PE were younger, and more likely to be tachycardic and require ICU admission. Of the echocardiographic indices, RV/LV EDD ratio > 0.7 was the most accurate predictor (sensitivity 66%, specificity 77%). The McConnell sign was the most specific (96%), however, with poor sensitivity (16%). Mean TR velocities did not differ between those with and without PE (270 +/- 74 vs. 294 +/- 83, P = 0.25). CONCLUSIONS: RV/LV EDD ratio > 0.7 has good accuracy for the diagnosis of acute PE. RV/LV area ratio > 0.7 and McConnell sign are specific but not sensitive indicators of acute pulmonary embolism. The presence of these findings should prompt further diagnostic testing for PE.


Asunto(s)
Ecocardiografía/métodos , Embolia Pulmonar/diagnóstico por imagen , Medición de Riesgo/métodos , Tomografía Computarizada Espiral/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad
7.
Eur J Radiol ; 85(5): 885-92, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27130047

RESUMEN

BACKGROUND: There is no accepted methodology for CT-based vasodilator stress myocardial perfusion imaging and analysis. We developed a technique for quantitative 3D analysis of CT images, which provides several indices of myocardial perfusion. We sought to determine the ability of these indices during vasodilator stress to identify segments supplied by coronary arteries with obstructive disease and to test the accuracy of the detection of perfusion abnormalities against SPECT. METHODS: We studied 93 patients referred for CT coronary angiography (CTCA) who underwent regadenoson stress. 3D analysis of stress CT images yielded segmental perfusion indices: mean X-ray attenuation, severity of defect and relative defect volume. Each index was averaged for myocardial segments, grouped by severity of stenosis: 0%, <50%, 50-70%, and >70%. Objective detection of perfusion abnormalities was optimized in 47 patients and then independently tested in the remaining 46 patients. RESULTS: CTCA depicted normal coronary arteries or non-obstructive disease in 62 patients and stenosis of >50% in 31. With increasing stenosis, segmental attenuation showed a 7% decrease, defect severity increased 11%, but relative defect volume was 7-fold higher in segments with obstructive disease (p<0.001). In the test group, detection of perfusion abnormalities associated with stenosis >50% showed sensitivity 0.78, specificity 0.54, accuracy 0.59. When compared to SPECT in a subset of 21 patients (14 with abnormal SPECT), stress CT perfusion analysis showed sensitivity 0.79, specificity 0.71, accuracy 0.76. CONCLUSIONS: 3D analysis of vasodilator stress CT images provides quantitative indices of myocardial perfusion, of which relative defect volume was most robust in identifying segments supplied by arteries with obstructive disease. This study may have implications on how CT stress perfusion imaging is performed and analyzed.


Asunto(s)
Arteriopatías Oclusivas/diagnóstico por imagen , Angiografía Coronaria/métodos , Imagenología Tridimensional/métodos , Purinas , Pirazoles , Tomografía Computarizada por Rayos X/métodos , Arteriopatías Oclusivas/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único/métodos , Vasodilatadores
8.
J Cardiovasc Comput Tomogr ; 5(4): 247-54, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21723516

RESUMEN

BACKGROUND: The ability of multidetector computed tomography (MDCT) to detect stress-induced myocardial perfusion abnormalities is of great clinical interest as a potential tool for the combined evaluation of coronary stenosis and its significance. However, stress testing requires repeated scanning that is associated with additional radiation exposure and iodine contrast. OBJECTIVE: Our goal was to determine the effects of reduced tube voltage and contrast dose on the ability to detect perfusion abnormalities. METHODS: We studied 40 patients referred for coronary CT angiography (CTA) who agreed to undergo additional imaging after administration of an A(2A)-agonist (regadenoson 0.4 mg). Images were acquired at rest and during hyperemia with prospective gating with 120 kV tube voltage with 80-90 mL of contrast in 20 patients (group 1) and 100 kV with 55-70 mL of contrast in the remaining 20 patients (group 2). Custom 3D analysis software was used to define 3D myocardial segments and measure x-ray attenuation in each segment. In each group of patients, myocardial attenuation was averaged for segments supplied by coronary arteries with stenosis causing >50% luminal narrowing on coronary CTA and separately for segments supplied by arteries without significant stenosis. RESULTS: Coronary CTA detected stenosis >50% in 23 of 120 coronary arteries in 16 of 40 patients. In all patients combined, myocardial attenuation increased from 86 ± 9 at rest to 110 ± 17 HU with stress, reflecting an increase in tissue blood flow, despite the decrease in left ventricular cavity attenuation (347 ± 72 to 281 ± 55 HU), reflecting an increase in cardiac output. Importantly, in both groups, myocardial attenuation was equally reduced in segments supplied by diseased arteries (group 1: 119 ± 19 vs 103 ± 14 HU, P < 0.05; group 2: 108 ± 20 vs 97 ± 16 HU, P < 0.05), despite the 74% reduction in radiation (from 7.4 ± 2.8 to 1.9 ± 0.45 mSv) and the 28% reduction in contrast dose (from 84 ± 7 to 60 ±7 mL) (both P < 0.05). CONCLUSIONS: Regadenoson stress MDCT imaging can detect hypoperfused myocardium even when imaging settings are optimized to provide a significant reduction in radiation and contrast doses.


Asunto(s)
Circulación Coronaria , Estenosis Coronaria/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Purinas , Pirazoles , Dosis de Radiación , Tomografía Computarizada por Rayos X , Vasodilatadores , Adulto , Anciano , Medios de Contraste , Estenosis Coronaria/fisiopatología , Femenino , Humanos , Hiperemia/diagnóstico por imagen , Hiperemia/fisiopatología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Índice de Severidad de la Enfermedad
9.
J Cardiol ; 53(2): 188-95, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19304121

RESUMEN

BACKGROUND: Recent developments in 2D speckle tracking imaging allow not only measurements of regional myocardial strain, but also velocities of the mitral annulus. The aim of this study was to determine the accuracy of speckle tracking derived mitral annulus velocity compared with conventional pulsed wave Doppler measurements. METHODS: 2D speckle tracking was acquired from the apical 4-chamber view (QLab, Speckle SQ, Philips, Andover, MA) in 169 subjects. While using texture tracking, two small regions of interest (ROIs) were placed in the septal (IVS) and lateral corners (LAT) of the mitral annulus. The software automatically tracked the ROIs frame-by-frame, yielding regional mean velocity curves of the mitral annulus throughout the cardiac cycle (synthetic pulsed wave Doppler; SPW). From these curves, peak systolic, early- and late-diastolic velocities of the mitral annulus (S'-SPW, E'-SPW, and A'-SPW) were measured. Peak systolic, early- and late-diastolic velocity in the mitral annulus (S', E', and A') by conventional pulsed wave tissue Doppler tracing were also obtained. RESULTS: Adequate ROI tracking was observed in 150/169 subjects in IVS and 139/169 subjects in LAT of the mitral annulus. All annular velocities derived from SPW were significantly lower than corresponding velocities obtained from conventional method in both IVS and LAT regions of the mitral annulus. However, significant correlation between S' (E', A')-SPW and S' (E', A') was observed. In particular, a good correlation between E'-SPW and E' was noted in both IVS (r=0.89, P<0.001) and LAT (r=0.85, P<0.001) regions of the mitral annulus. If we defined E/E'-SPW in IVS>26 for predicting E/E' in IVS>15, sensitivity, specificity, and accuracy were 83%, 97%, and 94%, respectively. E/E'-SPW in LAT>13 had a 94% sensitivity, 92% specificity, and 93% accuracy for predicting E/E' in LAT>10. CONCLUSIONS: The values of annular velocities by SPW were significantly lower compared to those assessed by traditional tissue velocities. However, new cut-off values of E/E'-SPW for predicting elevated LV filling pressure highly correlated with traditional parameters. 2D speckle tracking imaging provides another strategy for evaluating LV filling pressures.


Asunto(s)
Ecocardiografía/métodos , Válvula Mitral/diagnóstico por imagen , Diástole/fisiología , Ecocardiografía Doppler , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiología , Variaciones Dependientes del Observador
10.
Am J Cardiol ; 103(11): 1487-94, 2009 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-19463504

RESUMEN

Multidetector computed tomography (MDCT) is increasingly used as an alternative to invasive coronary angiography. Although computed tomographic coronary angiography (CTCA) has been validated against invasive coronary angiography and nuclear myocardial perfusion imaging, the potential of MDCT to evaluate perfusion has not been fully explored. We sought to (1) develop a new technique for quantitative assessment of myocardial enhancement based on analysis of MDCT images acquired for CTCA, (2) identify the underlying causes of myocardial hypoenhancement detected by MDCT, and (3) determine the added diagnostic value of the MDCT perfusion index when combined with CTCA. We studied 84 patients undergoing clinical CTCA (64 patients with invasive coronary angiogram and a control group of 20 patients). MDCT perfusion index was calculated from x-ray attenuation measured in 16 myocardial segments. Hypoenhancement was automatically detected using comparisons with the normal range obtained in the control group, and its added value was determined against invasive coronary angiographic findings combined with known previous myocardial infarction. Myocardial hypoenhancement was detected in 29 of 64 patients in 47 vascular territories, of which 36 (77%) were abnormal by the reference technique. Of these 36 abnormalities, 10 (28%) were associated with previous myocardial infarction, whereas 26 (72%) corresponded to significant coronary stenosis. The addition of MDCT perfusion index to CTCA improved its diagnostic accuracy (sensitivity 0.87 to 0.96, accuracy 0.84 to 0.88, despite a decrease in specificity 0.79 to 0.68). In conclusion, myocardial hypoenhancement is a potentially valuable addition to MDCT evaluation of coronary artery disease without additional cost in radiation dose or contrast load.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Anciano , Algoritmos , Angiografía Coronaria/métodos , Femenino , Humanos , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Cintigrafía , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
11.
J Echocardiogr ; 7(3): 48-54, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27278380

RESUMEN

BACKGROUND: Accurate preoperative determination of defect location and size is important for successful transcatheter closure of atrial septal defects (ASD). Real-time 3D transesophageal echocardiography (3DTEE) has the potential to delineate the shape of ASD in 3D space. METHODS: Full volume and 3D zoom datasets by 3DTEE were acquired in 17 ASD patients. Using quantitative software, maximal/minimal diameter, defect area and residual rim length were measured and compared to the standard 2D measurements. RESULTS: Real-time 3DTEE allowed delineation of the en-face view of the ASDs. The defect typically had an oval shape, and its size changed dynamically, having its minimal size at end-diastole and maximal at end-systole. A good correlation was noted between the maximal defect area by 3DTEE and 2DTEE (r = 0.93, p < 0.001). Successful delineation of rim length to the specific cardiac structure was 100% by 3DTEE and 88% by 2DTEE. There was a fair correlation of residual rim length between 3DTEE and 2DTEE (r = 0.69, p < 0.001). Eight patients underwent transcatheter closure of the ASD. Excellent correlation was noted between 3D-derived maximal defect diameter and device diameter (r = 0.97, p < 0.001). CONCLUSIONS: Real-time 3DTEE allows measurements of the temporal and spatial changes of ASD size and shape. This methodology provides detailed information on defect dynamics.

12.
J Am Soc Echocardiogr ; 21(12): 1362-8, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19041579

RESUMEN

BACKGROUND: The aim of this study was to determine the feasibility and accuracy of a new real-time 3-dimensional (RT3D) matrix-array transesophageal echocardiographic probe for the determination of left atrial appendage (LAA) geometry. METHODS: Sixty-six consecutive patients (mean age, 53 +/- 17 years) referred for 2-dimensional (2D) transesophageal echocardiography (TEE) underwent additional RT3D TEE. The feasibility of RT3D TEE for LAA geometry was studied in the first 37 patients, and 2D and RT3D transesophageal echocardiographic quantification of the LAA were compared in the subsequent 29 patients. The LAA orifice diameter and depth were measured using biplane 2D TEE, and LAA orifice area was calculated as an ellipse. LAA orifice area and depth were measured in 3D and correlated to 2D measurement and were also correlated to 64-slice cardiac computed tomography (CT) in 8 patients. RESULTS: All 66 patients underwent RT3D matrix-array TEE without complication. In the feasibility study, the LAA was well visualized in 95%. In the quantitation study, 2D TEE underestimated LAA orifice area compared with 3D imaging (3.1 +/- 1.3 vs 4.2 +/- 2.2 cm(2); r = 0.55). LAA depth by 2D and 3D imaging were well correlated (3.7 +/- 0.7 vs 3.4 +/- 0.7 cm; r = 0.77). LAA orifice area on CT was well correlated with area on 3D TEE (r = 0.98) but not with area 2D TEE (r = 0.13). Bland-Altman analysis demonstrated that 2D TEE systematically underestimated LAA orifice area compared with 3D TEE (mean bias, -1.0 cm(2), with wide limits of agreement [-4.6 to 2.6 cm(2)]). In the 8 patients who underwent both 3D TEE and CT, the mean bias was 0.15 cm(2), with narrow limits of agreement (-0.50 to 0.20 cm(2)). CONCLUSIONS: RT3D TEE for the visualization and quantitative analysis of LAA orifice area is feasible and correlates well with 64-slice cardiac CT.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Ecocardiografía Tridimensional/instrumentación , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/instrumentación , Ecocardiografía Transesofágica/métodos , Adulto , Anciano , Anciano de 80 o más Años , Sistemas de Computación , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Transductores
13.
J Am Soc Echocardiogr ; 20(2): 103-12, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17275694

RESUMEN

BACKGROUND: The availability of accurate noninvasive measurements of cardiac output (CO) would be useful in assessing disease severity and the effects of therapeutic interventions in many different clinical settings. Current noninvasive methods are limited by their dependence on geometric assumptions. We tested the feasibility of a new technique for CO measurements based on 3-dimensional color Doppler echocardiographic (3D-CD) imaging. OBJECTIVE: We sought to compare the accuracy of CO determination in human beings as measured by 3D-CD and conventional 2-dimensional echocardiography (2DE) using thermodilution as the gold standard for comparison. METHODS: Simultaneous 3D-CD, 2DE, and thermodilution data were acquired in 47 patients postcardiac transplantation with good acoustic windows who required routine hemodynamic evaluation with a pulmonary artery catheter. Data were stored on compact disc and analyzed offline using custom software. Echocardiographic data were compared against thermodilution using linear regression and Bland-Altman analysis. RESULTS: Correlation coefficients for 3D-CD and 2DE of the left ventricular outflow tract were r = 0.94 and r = 0.78, respectively. Correlation coefficients for 3D-CD and 2DE of the mitral valve were r = 0.93 and r = 0.75, respectively. Compared with 2DE, 3D-CD demonstrated a smaller bias and narrower limits of agreement in the left ventricular outflow tract (-1.84 +/- 16.8 vs -8.6 +/- 36.2 mL) and mitral valve inflow (-0.2 +/- 15.6 vs 10.0 +/- 26 mL). CONCLUSION: The 3D-CD determination of CO is feasible and accurate. Compared with previous noninvasive modalities, 3D-CD has the advantages of independence of geometric assumptions and ease of image acquisition and analysis.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Ecocardiografía Tridimensional/métodos , Trasplante de Corazón/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Volumen Sistólico , Termodilución/métodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Eur J Echocardiogr ; 7(3): 217-25, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16157510

RESUMEN

AIMS: Parametric imaging of myocardial perfusion provides useful visual information for the diagnosis of coronary artery disease (CAD). We developed a technique for automated detection of perfusion defects based on quantitative analysis of parametric perfusion images and validated it against coronary angiography. METHODS AND RESULTS: Contrast-enhanced, apical 2-, 3- and 4-chamber images were obtained at rest and with dipyridamole in 34 patients with suspected CAD. Images were analyzed to generate parametric perfusion images of the standard contrast-replenishment model parameters A, beta and A.beta. Each parametric image was divided into six segments, and mean parameter value (MPV) was calculated for each segment. Segmental MPV ratio between stress and rest was defined as a flow reserve index (FRI). Receiver operating characteristics (ROC) analysis was used in a Study group (N=17) to optimize FRI threshold and the minimal number of abnormal segments per vascular territory (LAD and non-LAD), required for automated detection of stress-induced perfusion defects. The optimized detection algorithm was then tested prospectively in the remaining 17 patients (Test group). LAD and non-LAD stenosis >70% was found in 19 and 17 patients, respectively. In the Study group, FRI threshold was: LAD=0.95 and non-LAD=0.68, minimal number of abnormal segments was four and two, correspondingly. Sensitivity, specificity and accuracy in the Test group were: 75%, 67% and 71% in the LAD, and 75%, 75% and 75% in the non-LAD territories. CONCLUSION: Automated quantitative analysis of contrast echocardiographic parametric perfusion images is feasible and may aid in the objective detection of CAD.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Dipiridamol , Ecocardiografía de Estrés , Isquemia Miocárdica/diagnóstico por imagen , Vasodilatadores , Anciano , Algoritmos , Medios de Contraste/farmacocinética , Angiografía Coronaria , Dipiridamol/farmacocinética , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Miocardio/metabolismo , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Vasodilatadores/farmacocinética
15.
Echocardiography ; 22(3): 225-32, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15725157

RESUMEN

BACKGROUND: Transthoracic Doppler echocardiography (TTDE) assessment of coronary flow velocity reserve (CFVR) has been validated in Asian and European centers. This methodology has not gained acceptability in the United States due to the bias that coronary flow velocity (CFV) by TTDE might be difficult in an obese population with relatively poor acoustic windows. METHODS: Baseline CFV in the left anterior descending coronary artery (LAD) by TTDE was obtained in 67 nonselected American patients. A subset of 38/67 received adenosine infusion for measuring CFVR of the LAD. PURPOSE: The aim of this study was twofold: (1) to determine the feasibility of measuring CFV and CFVR in the LAD by TTDE in a relatively obese American population, and (2) to compare CFV and CFVR values in this population with those previously obtained in a group of Japanese patients. RESULTS: The mean body mass index (BMI) of the American population (28 +/- 6 kg/m2, range: 18-46 kg/m2) was significantly higher than that of the Japanese group (23 +/- 4 kg/m2, range: 15-37 kg/m2). Twenty-five American patients were classified as obese (BMI >30 kg/m2). Baseline CFV was obtained in 60/67 patients (feasibility: 90%) with a 10% need for intravenous contrast agent to enhance the delineation of the CFV envelope. The success rate in recording CFVR in American patients (92%) was nearly identical to that of a Japanese group (99%). The time-averaged peak diastolic coronary flow velocity increased from 15.6 +/- 5.5 cm/sec at baseline to 47.1 +/- 17.9 cm/sec during adenosine infusion, and CFVR was calculated to be 3.22 +/- 1.15 (range: 0.94-5.69). Intraobserver and interobserver variability for the CFV recording was 4.7 and 6.2%, respectively. CONCLUSIONS: These results suggest that the noninvasive measurement of CFV and CFVR of the LAD is feasible even in a relatively obese American population. Furthermore, the success rates for recording CFV and CFVR are similar to those measured in a Japanese population. This methodology has the potential to provide useful physiological information on the coronary circulation in American patients.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Circulación Coronaria/fisiología , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler/métodos , Obesidad/diagnóstico por imagen , Adenosina/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Índice de Masa Corporal , Medios de Contraste , Ecocardiografía Doppler en Color , Estudios de Factibilidad , Femenino , Humanos , Infusiones Intravenosas , Japón , Masculino , Persona de Mediana Edad , Obesidad/fisiopatología , Estados Unidos , Vasodilatadores/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA