Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Ann Vasc Surg ; 35: 204.e1-4, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27236094

RESUMEN

Despite a high incidence of Staphylococcus aureus bacteremia in hemodialysis patients, bacterial invasion with aortic wall infection resulting in a pseudoaneurysm rarely occurs. This report describes a case of mycotic pseudoaneurysm of the abdominal aorta that grew rapidly and ruptured into the distal vena cava causing persistent bacteremia in a patient undergoing hemodialysis complicated with oxacillin-resistant S. aureus bacteremia.


Asunto(s)
Aneurisma Falso/microbiología , Aneurisma Infectado/microbiología , Antibacterianos/uso terapéutico , Aneurisma de la Aorta Abdominal/microbiología , Rotura de la Aorta/microbiología , Bacteriemia/microbiología , Resistencia a Medicamentos , Fallo Renal Crónico/terapia , Oxacilina/uso terapéutico , Diálisis Renal/efectos adversos , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/efectos de los fármacos , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/cirugía , Aneurisma Infectado/diagnóstico por imagen , Aneurisma Infectado/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/cirugía , Aortografía/métodos , Bacteriemia/diagnóstico , Angiografía por Tomografía Computarizada , Humanos , Fallo Renal Crónico/diagnóstico , Masculino , Persona de Mediana Edad , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/tratamiento farmacológico , Staphylococcus aureus/patogenicidad , Resultado del Tratamiento
2.
Nephrol News Issues ; 29(12): 30-3, 37, 42-4, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26677595

RESUMEN

The Hemodialysis Reliable Outflow (HeRO) graft was compared to the cuffed catheter in end-stage renal disease patients. All consented patients were evaluated for HeRO graft placement. Eligible patients that did not receive a graft were enrolled in the control group. Participants who had not exhausted peripheral venous access sites suitable for fistulas and grafts were excluded. Differences in quality of life and incidence of bacteremia, vascular interventions, hospitalizations, and death were evaluated over one year. In thirty-three patients included in the analysis--16 HeRO, 17 control--significantly fewer bacteremia events (93.8% vs. 64.7%) and a significantly increased number of vascular interventions (64.7% vs. 25%) were reported for the HeRO versus Control group. The increased interventions in the HeRO group may be due to the two-step placement process.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Catéteres de Permanencia , Fallo Renal Crónico/terapia , Diálisis Renal/métodos , Dispositivos de Acceso Vascular , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida
3.
BMJ Case Rep ; 15(3)2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35332004

RESUMEN

We present a case of a thoracic aortic mural thrombus (AMT) in a non-atherosclerotic and non-aneurysmal aorta that presented with acute limb ischaemia. AMT in a non-diseased aorta without an underlying hypercoagulable disorder is rare. The AMT in our patient was managed with anticoagulation, which resolved on a 5-month follow-up CT scan. This provided us an opportunity to discuss the successful medical management of an AMT, to review the literature on the management of AMT and to add to the literature on a rare presentation of an AMT.


Asunto(s)
Cardiopatías , Enfermedades Vasculares Periféricas , Trombosis , Aorta , Humanos , Isquemia/etiología , Trombosis/complicaciones , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico
4.
J Vasc Access ; 16(1): 64-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25198803

RESUMEN

PURPOSE: The purpose of this study is to report a novel two-stage Hemodialysis Reliable Outflow (HeRO) graft implantation technique that avoids the use of a femoral bridging hemodialysis catheter in internal jugular vein (IJV) catheter-dependent patients with contralateral central venous occlusion. METHODS: The first stage is to implant the ePTFE component and consists of: 1) performing two to three incisions in the upper arm ipsilateral to the preexisting IJV catheter, 2) tunneling the expanded polytetrafluoroethylene (ePTFE) component through these incision sites, and 3) placing the ePTFE component in the subcutaneous tissue without anastomosing it to the target artery. The preexisting IJV catheter is maintained to provide continuous dialysis access. The second stage is initiated in 4 weeks and includes: 1) thrombectomy and anastomosing the ePTFE component arterial end to the target artery, 2) insertion of the venous outflow component using the preexisting IJV catheter access site, and 3) connecting the venous outflow component to the ePTFE component in the standard fashion. RESULTS: The HeRO graft was successfully implanted in two stages without using a femoral bridging catheter. Immediate postimplant cannulatabilty was achieved upon completion of the second stage procedure. CONCLUSION: This novel two-stage HeRO implantation technique is simple, yet allows immediate cannulation upon completion of the second stage procedure while avoiding the need of a femoral bridging catheter in IJV catheter- dependent patients with contralateral central venous occlusion, and thus lowering the risk of infection related to a femoral bridging catheter.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/métodos , Prótesis Vascular , Cateterismo Venoso Central/instrumentación , Catéteres de Permanencia , Catéteres Venosos Centrales , Venas Yugulares , Fallo Renal Crónico/terapia , Diálisis Renal , Cateterismo , Humanos , Fallo Renal Crónico/diagnóstico , Politetrafluoroetileno , Diseño de Prótesis , Resultado del Tratamiento
5.
J Vasc Access ; 16(3): 189-94, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25613143

RESUMEN

PURPOSE: To evaluate a two-stage Hemodialysis Reliable Outflow (HeRO) implantation technique that avoids the use of a femoral bridging catheter versus the conventional one-stage technique requiring a bridging catheter in selected patients. METHODS: A retrospective review was performed on 20 end-stage renal disease patients with an internal jugular vein (IJV) catheter selected for two-stage HeRO implantation at our institution between January 2010 and March 2013. The arterial graft component (AGC) was implanted without anastomosing it to the target artery (first stage). After AGC incorporation, the venous outflow component was inserted (second stage). The preexisting IJV catheter was maintained for hemodialysis access during the interstage period. Patient characteristics, patency using Kaplan-Meier method and infection rates were analyzed. RESULTS: A total of 17 patients with a mean age of 59 years (70.6% women) completed the two-stage procedure. During the interstage period (mean 12 weeks, range 4-22 weeks), no graft- or surgery-related infection occurred. The need of a femoral bridging catheter was avoided by utilizing the preexisting IJV dialysis catheter. The accumulated HeRO days were 3,916 days with a mean follow-up of 7.7 months (range 1-22.6 months). The HeRO-related infection rate was 0.3/1,000 days. The primary assisted and secondary patency rates at 6 months were 69% and 82%, respectively, which were similar to those of arteriovenous grafts. Staging conferred immediate vascular accessibility. CONCLUSIONS: Avoiding the use of a femoral bridging catheter using the two-stage technique may lower infection rate, with comparable primary assisted and secondary patency to arteriovenous grafts and added benefit of immediate cannulatability in this subset of patients.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Cateterismo Periférico/instrumentación , Catéteres de Permanencia , Diálisis Renal , Extremidad Superior/irrigación sanguínea , Adulto , Anciano , Anciano de 80 o más Años , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Cateterismo Venoso Central/métodos , Cateterismo Periférico/efectos adversos , Femenino , Humanos , Venas Yugulares , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
6.
Vasc Endovascular Surg ; 37(1): 59-66, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12577140

RESUMEN

Aneurysms of the superior mesenteric artery (SMA) are an uncommon but lethal entity, which must be treated expeditiously to avoid mortality and high incidence of ischemic small bowel complications. In the past 7 years the authors have treated 4 patients with a variety of types of aneurysms involving the SMA and its branches at a university-based teaching hospital. The first was a mycotic SMA aneurysm as a result of septic mitral valve, the second a jejunal aneurysm in a patient with pancreatitis, the third a spontaneous dissection distal to a small SMA aneurysm with thrombus partially occluding the distal vessel, and the fourth an SMA aneurysm associated with the diagnosis of mesenteric insufficiency. All patients presented with abdominal pain. The diagnosis was made initially in 1 patient on plain abdominal films with a calcified aneurysm, on duplex scan in the second, and on computed tomography (CT) scans in the remaining 2. Treatment consisted of bowel resection and ligation of mycotic aneurysm in the first patient, of catheter embolization of jejunal aneurysm in the patient with pancreatitis, and of vein graft bypass in the patient with a large SMA aneurysm. The patient with SMA aneurysm and distal dissection with partially occluding thrombus received anticoagulation and is being followed up with serial CT scans. There were no deaths. One patient required bowel resection, which did not result in short gut syndrome. Improved abdominal duplex scanning and CT technology facilitates the diagnosis of mesenteric aneurysm. The broad spectrum of etiologies mandates that treatment be tailored to the individual patient, and it varies from endovascular techniques to traditional bypass surgery. Prompt diagnosis and treatment results in the lowest mortality rate and minimizes the prevalence of intestinal infarction.


Asunto(s)
Aneurisma/diagnóstico , Aneurisma/cirugía , Arteria Mesentérica Superior/diagnóstico por imagen , Arteria Mesentérica Superior/cirugía , Oclusión Vascular Mesentérica/diagnóstico , Oclusión Vascular Mesentérica/cirugía , Adulto , Aneurisma/complicaciones , Angiografía , Femenino , Humanos , Masculino , Oclusión Vascular Mesentérica/etiología , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Ultrasonografía Doppler Dúplex
7.
Am J Surg ; 202(2): 184-7, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21810498

RESUMEN

BACKGROUND: Various techniques for basilic vein transposition have been described, including endovascular, 1-stage, and 2-stage transposition. However, none of these 2-stage techniques include a new arteriovenous anastomosis during the second stage. This study adds to the current literature as well as introducing a new and innovative technique for hemodialysis access. METHODS: Forty-nine basilic vein transpositions were performed. Data were collected retrospectively. Primary and secondary patency was calculated using life table methods. Complications and interventions were recorded. RESULTS: Primary patency was 72% at 1 year, 54% at 2 years, and 54% at 3 years. Secondary patency was 95%, 80% and 65% at 1, 2, and 3 years, respectively. Twenty-nine patients experienced complications related to the fistula, and 15 required intervention to maintain patency. Patency was achieved in 100% of the procedures using percutaneous techniques. CONCLUSIONS: This 2-stage procedure should be strongly considered when planning brachial basilic fistulas for hemodialysis access.


Asunto(s)
Derivación Arteriovenosa Quirúrgica/métodos , Diálisis Renal , Extremidad Superior/irrigación sanguínea , Grado de Desobstrucción Vascular , Adulto , Anciano , Derivación Arteriovenosa Quirúrgica/efectos adversos , Femenino , Humanos , Tablas de Vida , Masculino , Persona de Mediana Edad , Flujo Sanguíneo Regional , Estudios Retrospectivos , Venas/cirugía
8.
Am J Surg ; 199(3): 369-71; discussion 371, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20226912

RESUMEN

BACKGROUND: This study evaluates the relationship between body mass index (BMI) and other comorbidities on the overall morbidity and mortality of abdominal aortic aneurysm (AAA) repair. METHODS: A database of all nonemergent open and endovascular AAA repairs performed at our center from 2004 to 2008 was created. The outcomes at the predefined time intervals were then evaluated for each group of patients. RESULTS: One hundred forty-three patients qualified for this study with a 3:2 stent graft-to-open ratio. A trend relating patient BMI with early mortality was noted. Age>80 years was a strong predictor of mortality in all time intervals. CONCLUSIONS: The outcomes for this population show a significant trend toward early mortality in open AAA repair patients with an elevated preoperative BMI. Appropriate patient selection and preoperative optimization are recommended for all AAA repair candidates; however, some innate characteristics such as patient age, may play the largest role in determining outcomes.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Índice de Masa Corporal , Complicaciones Posoperatorias/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos
9.
Ann Vasc Surg ; 16(3): 375-9, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-11957005

RESUMEN

Hypercoagulable conditions are increasingly recognized as a causative factor in patients with thromboembolic phenomenon. Essential thrombocytosis (ET) is one such condition. This particular myeloproliferative disorder is most commonly associated with thrombotic complications of the microvasculature and bleeding complications involving mucosal surfaces (e.g., gastrointestinal tract bleeding). This case identifies an uncommon manifestation of ET-aortic mural thrombus leading to visceral embolism. Vascular surgeons should be aware of the diagnosis, treatment, and complications of ET, as patients with this condition may first present with an arterial occlusion.


Asunto(s)
Cardiopatías/etiología , Infarto del Bazo/diagnóstico por imagen , Trombocitosis/complicaciones , Trombosis/etiología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Trombocitosis/diagnóstico , Tomografía Computarizada por Rayos X
10.
J Vasc Surg ; 35(5): 916-22, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12021707

RESUMEN

PURPOSE: Matrix metalloproteinases are enzymes capable of breaking down all of the components of the extracellular matrix and have been implicated in the development of aneurysm formation. Because matrix metalloproteinase-9 (MMP-9) levels are elevated in aortic aneurysmal tissue and in that patient plasma, we hypothesized that plasma MMP-9 levels should decrease significantly after conventional and endovascular infrarenal abdominal aortic aneurysm (AAA) repair but that plasma MMP-9 levels would remain elevated in patients with endoleaks. METHODS: A sandwich enzyme-linked immunosorbent assay was used to measure plasma levels of MMP-9 in patients with AAA who underwent conventional (n = 26; mean age, 71.5 years) and endovascular (n = 25; mean age, 76.4 years) AAA repair. Levels were drawn before surgery and at 1 month and 3 months after surgery. Eight patients for endovascular repair had endoleaks identified on postoperative computed axial tomographic scans. RESULTS: No correlation existed between preoperative plasma MMP-9 levels when compared with age, gender, or aneurysm diameter. No significant difference in preoperative plasma MMP-9 levels or AAA diameter was identified between patients with conventional repair compared with endovascular repair. Of the 51 patients, 33 had follow-up samples available for analysis. A significant increase in mean plasma MMP-9 levels was noted 1 month (149.5 +/- 40.1 ng/mL) after conventional AAA repair compared with preoperative levels (83.9 +/- 26.1 ng/mL; P <.05) and remained elevated 3 months after surgery (129.8 +/- 56.6 ng/mL). In those patients who underwent endovascular aneurysm exclusion without endoleak, a significant decrease in mean plasma MMP-9 levels was noted at 3 months (27.4 +/- 5.2 ng/mL) when compared with preoperative values (60.8 +/- 8.8 ng/mL; P <.01). In contrast, patients with endoleak after endovascular exclusion did not have a significant decrease in plasma MMP-9 levels at 3 months. CONCLUSION: Plasma MMP-9 levels remain elevated for as much as 3 months after conventional AAA repair, whereas successful endovascular exclusion of an AAA results in decreased plasma MMP-9 levels by 3 months. MMP-9 may have clinical value as an enzymatic marker for endoleak after endovascular AAA exclusion.


Asunto(s)
Aneurisma de la Aorta Abdominal/sangre , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Prótesis Vascular/efectos adversos , Metaloproteinasa 9 de la Matriz/sangre , Complicaciones Posoperatorias , Falla de Prótesis , Procedimientos Quirúrgicos Vasculares/efectos adversos , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Valor Predictivo de las Pruebas , Factores de Tiempo , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA