Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Interv Cardiol ; 2020: 8413831, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32665769

RESUMEN

AIMS: To investigate the healing process and nickel release of the Hyperion occluder (Comed BV, Netherlands), as compared to the Amplatzer septal occluder (ASO) (St. Jude Medical Inc., St. Paul, MN, USA) in a chronic swine model. BACKGROUND: Some long-term complications occurring after percutaneous atrial septal defect (ASD) closure may be partially associated with an inappropriate healing of the device and increased nickel release. There is no direct comparative study of different occluders for healing and nickel release. METHODS: After percutaneous ASD creation, 12 pigs were implanted with 15 mm Hyperion (n = 6) and 15 mm ASO (n = 6) devices. After 1 month (n = 3 for each device) and 3 months (n = 3 for each device) of follow-up, device explantation was performed and healing was assessed using histopathological workup. Systemic and tissular nickel release was performed. RESULTS: Implantation was successful in 100% without complications. Device coverage was observed as early as 1 month after implantation and was almost complete after 3 months. A granulation tissue with a predominantly mononuclear inflammatory reaction was observed in contact with nitinol wires while an inflammatory reaction was seen in contact with textile fibers. We found no statistically significant difference between the 2 devices whether for histological grading scores or systemic nickel release, regardless to follow-up duration. CONCLUSIONS: In this preclinical study, we demonstrated that Amplatzer septal occluder and Hyperion occluder were not significantly different for device healing and nickel release processes.


Asunto(s)
Aleaciones/farmacología , Defectos del Tabique Interatrial/cirugía , Efectos Adversos a Largo Plazo/inducido químicamente , Ensayo de Materiales/métodos , Complicaciones Posoperatorias/inducido químicamente , Implantación de Prótesis , Dispositivo Oclusor Septal/efectos adversos , Aleaciones/efectos adversos , Animales , Investigación sobre la Eficacia Comparativa , Efectos Adversos a Largo Plazo/prevención & control , Níquel/efectos adversos , Níquel/farmacología , Evaluación de Resultado en la Atención de Salud , Complicaciones Posoperatorias/prevención & control , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Porcinos , Oligoelementos/efectos adversos , Oligoelementos/farmacología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA