Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Transplant ; 36(8): e14717, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35598116

RESUMEN

INTRODUCTION: To evaluate the initial use of label-free second harmonic generation (SHG) imaging with two-photon excitation (2PE) auto-fluorescence in multiphoton microscopy (MPM) for the quantification of collagen/fibrosis on preimplantation biopsies of extended criteria donors (ECD). MATERIALS AND METHODS: Twenty preimplantation core biopsies were extracted from 10 donor kidney samples, of which originated from seven donors. Kidney Donor Profile Index (KDPI) and Remuzzi scores of biopsies were calculated. Collagen parameters measured included quantification by the Collagen Area Ratio in Total Tissue (CART) and qualitative measurements by Collagen Reticulation Index (CRI). RESULTS: Biopsies classified with > 85% KDPI scores had significantly higher CART (p = .011) and lower CRI values (p = .025) than biopsies with ≤ 85% KDPI scores. Increase in CRI values correlated significantly with rise in recipient creatinine levels 1-year post-transplant (p = .027; 95% CI: 4.635-66.797). CONCLUSION: MPM is an evolving technology that enables the quantification of the amount (CART) and quality (CRI) of collagen deposition in unstained preimplantation biopsies of donor kidneys stratified by KDPI scores. This initial evaluation found significant differences in both parameters between donor kidneys with more or less than 85% KDPI.


Asunto(s)
Trasplante de Riñón , Enfermedades Pulmonares Intersticiales , Colágeno , Fibrosis , Supervivencia de Injerto , Humanos , Riñón/patología , Trasplante de Riñón/efectos adversos , Trasplante de Riñón/métodos , Microscopía , Estudios Retrospectivos , Donantes de Tejidos
2.
Urol Int ; 106(12): 1279-1286, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35709703

RESUMEN

INTRODUCTION: Perceived benefits like decreased contamination rates and reduced postoperative incidence of complications after urolithiasis surgery have led to increased adoption of single-use flexible ureteroscopes (su-fURS). Using a validated, standardized simulator model with enhanced "fluoroscopic" capabilities, we performed an in vitro comparative assessment of four commercially available models of su-fURS. Both objective and subjective parameters were assessed in this study. METHODS: Two standardized tasks, (1) exploration of the model's kidney collecting system and (2) repositioning of a stone fragment from the upper renal to lower renal pole were assigned to participants, who performed these tasks on all four scopes. Four models of su-fURS (Boston LithoVue, PUSEN PU3033A, REDPINE, INNOVEX EU-ScopeTM) were assessed, with task timings as end-points for objective analysis. Cumulative "fluoroscopic" time was also recorded as a novel feature of our enhanced model. Post-task questionnaires evaluating specific components of the scopes were distributed to document subjective ratings. RESULTS: Both subjective and objective performances (except stone repositioning time) across all four su-fURS demonstrated significant differences. However, objective performance (task timings) did not reflect subjective scope ratings by the participants (Rs < 0.6). Upon Kruskal-Wallis H test with post hoc analyses, REDPINE and INNOVEX EU-ScopeTM were the preferred su-fURS as rated by the participants, with overall scope scores of 9.00/10 and 9.57/10. CONCLUSIONS: Using a standardized in vitro simulation model with enhanced fluoroscopic capabilities, we demonstrated both objective and subjective differences between models of su-fURS. However, variations in perception of scope features (visibility, image quality, deflection, maneuverability, ease of stone retrieval) did not translate into actual technical performance. Eventually, the optimal choice of su-fURS fundamentally lies in individual surgeon preference, as well as cost-related factors.

3.
Glia ; 66(3): 492-504, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29134678

RESUMEN

Chronic inflammation represents a central component in the pathogenesis of Alzheimer's disease (AD). Recent work suggests that breaking immune tolerance by Programmed cell Death-1 (PD1) checkpoint inhibition produces an IFN-γ-dependent systemic immune response, with infiltration of the brain by peripheral myeloid cells and neuropathological as well as functional improvements even in mice with advanced amyloid pathology (Baruch et al., (): Nature Medicine, 22:135-137). Immune checkpoint inhibition was therefore suggested as potential treatment for neurodegenerative disorders when activation of the immune system is appropriate. Because a xenogeneic rat antibody (mAb) was used in the study, whether the effect was specific to PD1 target engagement was uncertain. In the present study we examined whether PD1 immunotherapy can lower amyloid-ß pathology in a range of different amyloid transgenic models performed at three pharmaceutical companies with the exact same anti-PD1 isotype and two mouse chimeric variants. Although PD1 immunotherapy stimulated systemic activation of the peripheral immune system, monocyte-derived macrophage infiltration into the brain was not detected, and progression of brain amyloid pathology was not altered. Similar negative results of the effect of PD1 immunotherapy on amyloid brain pathology were obtained in two additional models in two separate institutions. These results show that inhibition of PD1 checkpoint signaling by itself is not sufficient to reduce amyloid pathology and that additional factors might have contributed to previously published results (Baruch et al., (): Nature Medicine, 22:135-137). Until such factors are elucidated, animal model data do not support further evaluation of PD1 checkpoint inhibition as a therapeutic modality for Alzheimer's disease.


Asunto(s)
Enfermedad de Alzheimer/terapia , Péptidos beta-Amiloides/metabolismo , Anticuerpos/administración & dosificación , Encéfalo/inmunología , Inmunoterapia , Receptor de Muerte Celular Programada 1/inmunología , Enfermedad de Alzheimer/inmunología , Enfermedad de Alzheimer/patología , Péptidos beta-Amiloides/genética , Animales , Anticuerpos/metabolismo , Encéfalo/patología , Modelos Animales de Enfermedad , Femenino , Humanos , Inmunohistoquímica , Interferón gamma/sangre , Masculino , Ratones Endogámicos C57BL , Ratones Transgénicos , Presenilina-1/genética , Presenilina-1/metabolismo , ARN Mensajero/metabolismo , Distribución Aleatoria , Bazo/inmunología
4.
J Urol ; 210(4): 609-610, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37681536
5.
Mol Pharm ; 13(3): 915-23, 2016 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-26849155

RESUMEN

Antibodies at high concentrations often reveal unanticipated biophysical properties suboptimal for therapeutic development. The purpose of this work was to explore the use of point mutations based on crystal structure information to improve antibody physical properties such as viscosity and phase separation (LLPS) at high concentrations. An IgG4 monoclonal antibody (Mab4) that exhibited high viscosity and phase separation at high concentration was used as a model system. Guided by the crystal structure, four CDR point mutants were made to evaluate the role of hydrophobic and charge interactions on solution behavior. Surprisingly and unpredictably, two of the charge mutants, R33G and N35E, showed a reduction in viscosity and a lower propensity to form LLPS at high concentration compared to the wild-type (WT), while a third charge mutant S28K showed an increased propensity to form LLPS compared to the WT. A fourth mutant, F102H, had reduced hydrophobicity, but unchanged viscosity and phase separation behavior. We further evaluated the correlation of various biophysical measurements including second virial coefficient (A2), interaction parameter (kD), weight-average molecular weight (WAMW), and hydrodynamic diameters (DH), at relatively low protein concentration (4 to 15 mg/mL) to physical properties, such as viscosity and liquid-liquid phase separation (LLPS), at high concentration. Surprisingly, kD measured using dynamic light scattering (DLS) at low antibody concentration correlated better with viscosity and phase separation than did A2 for Mab4. Our results suggest that the high viscosity and phase separation observed at high concentration for Mab4 are mainly driven by charge and not hydrophobicity.


Asunto(s)
Anticuerpos Monoclonales/química , Inmunoglobulina G/inmunología , Extracción Líquido-Líquido/métodos , Ingeniería de Proteínas/métodos , Viscosidad , Sustitución de Aminoácidos , Anticuerpos Monoclonales/genética , Anticuerpos Monoclonales/uso terapéutico , Cristalización , Humanos , Concentración de Iones de Hidrógeno , Concentración Osmolar , Soluciones Farmacéuticas , Conformación Proteica
6.
Surg Endosc ; 30(5): 1742-6, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26173550

RESUMEN

BACKGROUND: It has been postulated that increased operator workload during task performance may increase fatigue and surgical errors. The National Aeronautics and Space Administration-Task Load Index (NASA-TLX) is a validated tool for self-assessment for workload. Our study aims to assess the relationship of workload and performance of novices in simulated laparoscopic tasks of different complexity levels before and after training. METHODS: Forty-seven novices without prior laparoscopic experience were recruited in a trial to investigate whether training improves task performance as well as mental workload. The participants were tested on three standard tasks (ring transfer, precision cutting and intracorporeal suturing) in increasing complexity based on the Fundamentals of Laparoscopic Surgery (FLS) curriculum. Following a period of training and rest, participants were tested again. Test scores were computed from time taken and time penalties for precision errors. Test scores and NASA-TLX scores were recorded pre- and post-training and analysed using paired t tests. One-way repeated measures ANOVA was used to analyse differences in NASA-TLX scores between the three tasks. RESULTS: NASA-TLX score was lowest with ring transfer and highest with intracorporeal suturing. This was statistically significant in both pre-training (p < 0.001) and post-training (p < 0.001). NASA-TLX scores mirror the changes in test scores for the three tasks. Workload scores decreased significantly after training for all three tasks (ring transfer = 2.93, p < 0.001, precision cutting = 3.74, p < 0.001, intracorporeal suturing = 2.98, p < 0.001). CONCLUSION: NASA-TLX score is an accurate reflection of the complexity of simulated laparoscopic tasks in the FLS curriculum. This also correlates with the relationship of test scores between the three tasks. Simulation training improves both performance score and workload score across the tasks.


Asunto(s)
Competencia Clínica , Educación de Pregrado en Medicina , Laparoscopía/educación , Entrenamiento Simulado , Análisis y Desempeño de Tareas , Carga de Trabajo , Adulto , Curriculum , Femenino , Humanos , Masculino , Singapur , Técnicas de Sutura/educación , Adulto Joven
7.
Int J Colorectal Dis ; 30(3): 409-12, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25575433

RESUMEN

BACKGROUND: The management of high anal fistula is often complicated and challenging. In spite of numerous new techniques, the advancement flap technique remained an integral procedure in its management. The purpose of this study was to determine the long-term outcome of advancement flap procedures for high anal fistulas. METHODS: A retrospective review of patients who have undergone an advancement flap procedure for high anal fistula of cryptoglandular origin from June 2003 to April 2012 was performed. Patients were contacted via telephone to evaluate their continence status using the Wexner score. RESULTS: Sixty-one patients with a median age of 48 (range, 19-74) years and a median follow-up of 6.5 (range, 1-59) months were evaluated. Fifty-three (86.9 %) patients had successful surgery while 8 (13.1 %) failed the procedure. Four of them underwent subsequent surgery. Of the 53 patients who had a successful procedure, 27 were successfully contacted for a telephone interview. Twenty-one (77.8 %) of them reported a Wexner score of '0'. Two (7.4 %) patients had a Wexner score of <4, another 2 had a score of '4' and '10', while the last 2 patients had a score of >10. CONCLUSION: Advancement flap procedure is effective in the management of high anal fistulas with an acceptable success rate. The majority of the patients experienced good anal continence.


Asunto(s)
Pueblo Asiatico , Fístula Rectal/etnología , Fístula Rectal/cirugía , Colgajos Quirúrgicos , Adulto , Anciano , Incontinencia Fecal/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Recurrencia , Estudios Retrospectivos , Singapur , Resultado del Tratamiento , Adulto Joven
8.
Histopathology ; 65(6): 879-96, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25039923

RESUMEN

AIMS: Development of novel targeted therapies directed against hepatocyte growth factor (HGF) or its receptor (MET) necessitates the availability of quality diagnostics to facilitate their safe and effective use. Limitations of some commercially available anti-MET antibodies have prompted development of the highly sensitive and specific clone A2H2-3. Here we report its analytical properties when applied by an automated immunohistochemistry method. METHODS AND RESULTS: Excellent antibody specificity was demonstrated by immunoblot, ELISA, and IHC evaluation of characterised cell lines including NIH3T3 overexpressing the related kinase MST1R (RON). Sensitivity was confirmed by measurements of MET in cell lines or characterised tissues. IHC correlated well with FISH and quantitative RT-PCR assessments of MET (P < 0.001). Good total agreement (89%) was observed with the anti-MET antibody clone SP44 using whole-tissue sections, but poor positive agreement (21-47%) was seen in tissue microarray cores. Multiple lots displayed appropriate reproducibility (R(2)  > 0.9). Prevalence of MET positivity by IHC was higher in non-squamous cell NSCLC, MET or EGFR amplified cases, and in tumours harbouring abnormalities in EGFR exon 19 or 21. CONCLUSIONS: The anti-MET antibody clone A2H2-3 displays excellent specificity and sensitivity. These properties make it suitable for clinical trial investigations and development as a potential companion diagnostic.


Asunto(s)
Anticuerpos Monoclonales , Neoplasias/genética , Proteínas Proto-Oncogénicas c-met/análisis , Adulto , Anciano , Animales , Especificidad de Anticuerpos , Western Blotting , Análisis Mutacional de ADN , Femenino , Humanos , Inmunohistoquímica , Hibridación Fluorescente in Situ , Masculino , Ratones , Persona de Mediana Edad , Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad , Análisis de Matrices Tisulares
9.
Int Urol Nephrol ; 56(1): 97-102, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37653357

RESUMEN

BACKGROUND: Selecting the smaller kidney for donation has been advocated if there is a size difference of > 10% between the 2 kidneys but has never been prospectively evaluated. With increase in donor nephrectomies, it is important to evaluate this to minimize loss of renal function to donors. METHODS: 75 consecutive donor nephrectomy patients were included in our longitudinal study. The Split Renal Volume (SRV) of bilateral kidneys were measured using contrasted computer tomography scans and patients segregated into 2 groups depending on donated kidney having more (Group 1) or less than (Group 2) 52.5% of SRV. RESULTS: Patients in Group 1 (n = 19) and 2 (n = 56) were of similar age (43.8 vs. 48.3), BMI (22.4 vs. 25.2), sex (57.9 vs. 55.4% women), respectively. Although total kidney volumes were similar in both groups, Group 1 had significantly smaller right kidney volumes (120.4 ± 24.9 vs. 142.7 ± 28.4 mls, p = 0.003). EGFR pre-operatively (116.3 ± 20.8 vs. 106.3 ± 23.8 mL/min/1.73 m2) and at 6-months (65.7 ± 13.3 vs. 66.9 ± 15.5 mL/min/1.73 m2) were not different between groups. However, patients in Group 1 had significantly greater absolute (50.6 ± 14.9 vs. 39.5 ± 14.7 mL/min/1.73 m2) and relative decline (43.0 ± 8.6 vs. 36.3 ± 10.6%) in eGFR at 6 months (p = 0.06, 0.009). CONCLUSION: With a SRV difference of 5% between the 2 sides, removal of the larger kidney for living kidney donation resulted in greater early decline of renal function than kidney donors whose larger or equivalent kidney is preserved.


Asunto(s)
Trasplante de Riñón , Humanos , Femenino , Masculino , Trasplante de Riñón/métodos , Nefrectomía/efectos adversos , Nefrectomía/métodos , Donadores Vivos , Estudios Longitudinales , Estudios Retrospectivos , Riñón/diagnóstico por imagen , Tasa de Filtración Glomerular , Tomografía Computarizada por Rayos X/métodos
10.
PLoS One ; 19(4): e0293703, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38630694

RESUMEN

Many oncology antibody-drug conjugates (ADCs) have failed to demonstrate efficacy in clinic because of dose-limiting toxicity caused by uptake into healthy tissues. We developed an approach that harnesses ADC affinity to broaden the therapeutic index (TI) using two anti-mesenchymal-epithelial transition factor (MET) monoclonal antibodies (mAbs) with high affinity (HAV) or low affinity (LAV) conjugated to monomethyl auristatin E (MMAE). The estimated TI for LAV-ADC was at least 3 times greater than the HAV-ADC. The LAV- and HAV-ADCs showed similar levels of anti-tumor activity in the xenograft model, while the 111In-DTPA studies showed similar amounts of the ADCs in HT29 tumors. Although the LAV-ADC has ~2-fold slower blood clearance than the HAV-ADC, higher liver toxicity was observed with HAV-ADC. While the SPECT/CT 111In- and 124I- DTPA findings showed HAV-ADC has higher accumulation and rapid clearance in normal tissues, intravital microscopy (IVM) studies confirmed HAV mAb accumulates within hepatic sinusoidal endothelial cells while the LAV mAb does not. These results demonstrated that lowering the MET binding affinity provides a larger TI for MET-ADC. Decreasing the affinity of the ADC reduces the target mediated drug disposition (TMDD) to MET expressed in normal tissues while maintaining uptake/delivery to the tumor. This approach can be applied to multiple ADCs to improve the clinical outcomes.


Asunto(s)
Inmunoconjugados , Radioisótopos de Yodo , Humanos , Animales , Preparaciones Farmacéuticas , Células Endoteliales/metabolismo , Línea Celular Tumoral , Inmunoconjugados/uso terapéutico , Ácido Pentético , Ensayos Antitumor por Modelo de Xenoinjerto
11.
Transplant Direct ; 10(4): e1604, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38464423

RESUMEN

Background: The Canadian Anatomic Kidney Score (CAKS) is a novel 6-point grading system that standardizes the gross description of a donor kidney across 3 components-vessels, anatomy, and sticky fat. We hypothesized that the CAKS predicts allograft functional outcomes and provides additional information to the Kidney Donor Profile Index (KDPI) and histologic assessment of the donor kidney. Methods: Single-center cohort of 145 patients who underwent renal transplantation with CAKS analysis between 2018 and 2021. CAKS was prospectively determined before transplantation. Preimplantation core biopsies were assessed according to the Remuzzi score (RS). The primary outcome was 1-y allograft function represented by an estimated glomerular filtration rate (eGFR). Results: Linear regression without adjustment for KDPI or RS showed a significant association between the CAKS and 1-y eGFR (-8.7 mL/min/1.73 m2 per point increase in CAKS; 95% CI, -13.0 to -4.4; P < 0.001). Most of that association was attributed to the vessel component (-12.1; -19.4 to -4.8; P = 0.002). Adjustment for KDPI and RS attenuated the relationship between 1-y function and CAKS (-4.6; -9.5 to 0.3; P = 0.065) and vessel component (-7.4; -15.2 to 0.5; P = 0.068). Conclusions: Anatomic assessment of donor kidneys at the time of transplantation associates with allograft function at 1 y. Vascular assessment appears to make the dominant contribution.

12.
Mol Pharm ; 10(4): 1322-31, 2013 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-23383873

RESUMEN

A key challenge in developing therapeutic antibodies is their highly variable propensities to self-associate at high antibody concentrations (>50 mg/mL) required for subcutaneous delivery. Identification of monoclonal antibodies (mAbs) in the initial discovery process that not only have high binding affinity but also have high solubility and low viscosity would simplify the development of safe and effective antibody therapeutics. Unfortunately, the low purities, small quantities and large numbers of antibody candidates during the early discovery process are incompatible with current methods of measuring antibody self-association. We report a method (affinity-capture self-interaction nanoparticle spectroscopy, AC-SINS) capable of identifying mAbs with low self-association propensity that is robust even at low mAb concentrations (5-50 µg/mL) and in the presence of cell culture media. Gold nanoparticles are coated with polyclonal antibodies specific for human antibodies, and then human mAbs are captured from dilute antibody solutions. We find that the wavelength of maximum absorbance (plasmon wavelength) of antibody-gold conjugates--which red-shifts as the distance between particles is reduced due to attractive mAb self-interactions--is well correlated with light scattering measurements conducted at several orders of magnitude higher antibody concentrations. The generality of AC-SINS makes it well suited for use in diverse settings ranging from antibody discovery to formulation development.


Asunto(s)
Anticuerpos Monoclonales/química , Inmunohistoquímica , Adsorción , Química Farmacéutica/métodos , Medios de Cultivo/química , Difusión , Diseño de Fármacos , Humanos , Cinética , Luz , Nanopartículas/química , Nanotecnología/métodos , Dispersión de Radiación , Solubilidad , Viscosidad
13.
Drug Metab Dispos ; 40(8): 1545-55, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22584253

RESUMEN

The pH-dependent binding of IgGs to the neonatal Fc receptor (FcRn) plays a critical role in regulating IgG homeostasis in vivo. Enhancing interactions between Fc and FcRn via protein engineering has been successfully used as an approach for improving the pharmacokinetics of monoclonal antibodies (mAbs). Although the quantitative translatability of the in vitro FcRn affinity enhancement to an in vivo pharmacokinetic benefit has been supported by several studies, there are also published reports indicating a disconnect in this relation. The body of literature suggests there are likely additional biochemical and biophysical properties of the mAbs along with their FcRn affinity that influence the in vivo pharmacokinetics. Herein, we more broadly evaluate the in vitro Fc-FcRn interactions and biochemical properties of five humanized IgG4 antibodies each with two Fc variant sequences (T250Q/M428L and V308P) and their corresponding pharmacokinetics in cynomolgus monkeys. Our findings indicate that the FcRn affinity-pharmacokinetic relationship does not show a direct correlation either across different IgGs or between the two variant sequences within a platform. Other parameters that have been suggested to contribute to mAb pharmacokinetic properties, such as the pH-dependent dissociation of the FcRn-IgG complexes, mAb biophysical properties, and nonspecific/charge binding characteristics of the mAbs, also did not independently explain the differing pharmacokinetic behaviors. Our results suggest that there is likely not a single in vitro parameter that readily predicts in vivo pharmacokinetics, but that the relative contribution and interplay of several factors along with the FcRn binding affinity are important determinants of mAb pharmacokinetic properties.


Asunto(s)
Antígenos de Histocompatibilidad Clase I/metabolismo , Inmunoglobulina G/metabolismo , Receptores Fc/metabolismo , Animales , Línea Celular , Humanos , Inmunoglobulina G/química , Técnicas In Vitro , Macaca fascicularis , Unión Proteica
14.
J Pept Sci ; 17(5): 383-6, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21412957

RESUMEN

Calcitonin gene-related peptide (CGRP), a potent dilator of cerebral and dural vasculature, is known to be elevated in plasma and cerebral spinal fluid during migraine attacks. Selective blockade of the CGRP receptor offers the promise of controlling migraine headache more effectively and without the side-effects associated with the use of triptans. Our efforts to develop a novel, peptide-based CGRP antagonist focused on the C-terminal portion of the peptide which is known to bind the receptor but lack agonist properties. Extensive SAR studies of the C-terminal CGRP (27-37) region identified a novel cyclic structure: Bz-Val-Tyr-cyclo[Cys-Thr-Asp-Val-Gly-Pro-Phe-Cys]-Phe-NH(2) (23) with a kb value of 0.126 nM against the cloned human CGRP receptor. Additional SAR studies directed at enhancement of potency and improvement of physicochemical properties yielded a series of analogs with kb values in the 0.05-0.10 nM range.


Asunto(s)
Antagonistas del Receptor Peptídico Relacionado con el Gen de la Calcitonina , Péptidos/química , Péptidos/farmacología , Humanos
15.
Asian J Urol ; 8(2): 215-219, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33996479

RESUMEN

OBJECTIVE: Simulation based training with training models is being increasingly used as a tool to help trainees mount the learning curve. However, validation studies of surgical simulators are often limited by small numbers. We aim to evaluate the feasibility of validating simulation-training tasks in laparoscopy and flexible ureteroscopy (FURS) rapidly at a large-scale conference setting for residents. METHODS: Seventy-six urology residents from various Asian countries were assessed on their laparoscopic and FURS skills during the 14th Urological Association of Asia Congress 2016. Residents performed the peg transfer task from the fundamentals of laparoscopic surgery (FLS) and completed inspection of calyces and stone retrieval using a flexible ureteroscope in an endourological model. Each participant's experience (no experience, 1-30 or >30 procedures) in laparoscopy, rigid ureteroscopy (RURS) and FURS was self-reported. RESULTS: Median time taken to complete the laparoscopic task decreased with increasing laparoscopic experience (209 s vs. 177 s vs. 145 s, p=0.008) whereas median time taken to complete the FURS tasks reduced with increasing FURS experience (405 s vs. 250 s vs. 163 s, p=0.003) but not with RURS experience (400.5 s vs. 397 s vs. 331 s, p=0.143), demonstrating construct validity. Positive educational impact of both tasks was high, with mean ratings of 4.16/5 and 4.10/5 respectively, demonstrating face validity. CONCLUSION: Our study demonstrates construct and face validities of laparoscopy and FURS simulation tasks among residents at a conference setting. Validation studies at a conference setting can be an effective avenue for evaluating simulation models and curriculum in the future.

16.
Urology ; 147: 14-20, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33091386

RESUMEN

OBJECTIVE: To assess the effectiveness of a telemedicine service for ureteric colic patients in reducing the number of unnecessary face-to-face consultations and shortening waiting time for appointments. METHODS: A telemedicine workflow was implemented as a quality improvement study using the Plan-Do-Study-Act method. All patients presenting with ureteric colic without high-risk features of fever, severe pain, and hydronephrosis, were recruited, and face-to-face appointments to review scan results were replaced with phone consultations. Data were prospectively collected over 3 years (January 2017 to December 2019). Patient outcomes including the reduction in face-to-face review visits, time to review, reattendance and intervention rates, were tracked in an interrupted time-series analysis, and qualitative feedback was obtained from patients and clinicians. RESULTS: Around 53.2% of patients presenting with ureteric colic were recruited into the telemedicine workflow. A total of 465 patients (46.2%) had normal scan results and 250 patients (24.9%) did not attend their scan appointments, hence reducing the number of face-to-face consultations by 71.1%. A total of 230 patients (22.9%) required subsequent follow-up with urology, while 61 patients (6.1%) were referred to other specialties. Mean (SD) time to review was 30.0 (6.2) days, 6-month intervention rate was 3.4% (n = 34) and unplanned reattendance rate was 3.2% (n = 32). Around 93.1% of patients reported satisfaction with the service. CONCLUSION: The ureteric colic telemedicine service successfully and sustainably reduced the number of face-to-face consultations and time to review without compromising on patient safety. The availability of this telemedicine service has become even more important in helping us provide care to patients with ureteric colic in the current COVID-19 pandemic.


Asunto(s)
Mejoramiento de la Calidad , Consulta Remota/organización & administración , Cólico Renal/diagnóstico , Cálculos Ureterales/diagnóstico , Urología/organización & administración , Adulto , COVID-19/epidemiología , COVID-19/prevención & control , Femenino , Implementación de Plan de Salud/organización & administración , Humanos , Control de Infecciones/organización & administración , Control de Infecciones/normas , Masculino , Persona de Mediana Edad , Pandemias/prevención & control , Seguridad del Paciente/normas , Satisfacción del Paciente , Proyectos Piloto , Estudios Prospectivos , Investigación Cualitativa , Consulta Remota/normas , Cólico Renal/etiología , Cólico Renal/terapia , Singapur/epidemiología , Teléfono , Centros de Atención Terciaria/organización & administración , Centros de Atención Terciaria/normas , Tomografía Computarizada por Rayos X , Uréter/diagnóstico por imagen , Cálculos Ureterales/complicaciones , Cálculos Ureterales/terapia , Urología/métodos , Urología/normas
17.
MAbs ; 12(1): 1770028, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32486889

RESUMEN

Many therapeutic monoclonal antibodies (mAbs) were initially developed for intravenous (IV) administration. As a means to improve mAb drug-ability and the patient experience, subcutaneous (SC) administration is an increasingly important delivery route for mAbs. Unlike IV administration, bioavailability limitations for antibodies have been reported following SC injection and can dictate whether a mAb is administered via this parenteral route. The SC bioavailability of antibodies has been difficult to predict, and it can be variable and partial, with values ranging from ~50% to 100%. The mechanisms leading to the incomplete bioavailability of some mAbs relative to others are not well understood. There are some limited data that suggest the physiochemical properties inherent to a mAb can contribute to its SC absorption, bioavailability, and in vivo fate. In this study, we evaluated the integrated influence of multiple mAb physiochemical factors on the SC absorption and bioavailability of six humanized mAbs in both rats and cynomolgus monkeys. We demonstrate the physiochemical properties of mAbs are critical to their rate and extent of SC absorption. The combination of high positive charge and hydrophobic interaction significantly reduced the rate of the evaluated mAb's SC absorption and bioavailability. Reduction or balancing of both these attributes via re-engineering the mAbs restored desirable properties of the molecules assessed. This included reduced association with SC tissue, improvements in mAb absorption from the SC space and overall SC bioavailability. Our findings point to the importance of evaluating the relative balance between various physiochemical factors, including charge, hydrophobicity, and stability, to improve the SC drug-ability of mAbs for selecting or engineering mAbs with enhanced in vivo absorption and bioavailability following SC administration.


Asunto(s)
Anticuerpos Monoclonales Humanizados/farmacocinética , Química Física/métodos , Animales , Anticuerpos Monoclonales Humanizados/química , Bioingeniería , Disponibilidad Biológica , Desarrollo de Medicamentos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Inyecciones Subcutáneas , Macaca fascicularis , Unión Proteica , Estabilidad Proteica , Ratas , Absorción Subcutánea
18.
MAbs ; 12(1): 1764829, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32370596

RESUMEN

Biologics have the potential to induce an immune response when used therapeutically. A number of in vitro assays are currently used preclinically to predict the risk of immunogenicity, but the validation of these preclinical tools suffers from the relatively small number of accessible immunogenic molecules and the limited understanding of the mechanisms underlying the immunogenicity of biologics. Here, we present the post-hoc analysis of three monoclonal antibodies with high immunogenicity in the clinic. Two of the three antibodies elicited a CD4 T cell proliferative response in multiple donors in a peripheral blood mononuclear cell assay, but required different experimental conditions to induce these responses. The third antibody did not trigger any T cell response in this assay. These distinct capacities to promote CD4 T cell responses in vitro were mirrored by different capacities to stimulate innate immune cells. Only one of the three antibodies was capable of inducing human dendritic cell (DC) maturation; the second antibody promoted monocyte activation while the third one did not induce any innate cell activation in vitro. All three antibodies exhibited a moderate to high internalization by human DCs and MHC-associated peptide proteomics analysis revealed the presence of potential T cell epitopes that were confirmed by a T-cell proliferation assay. Collectively, these findings highlight the existence of distinct immune stimulatory mechanisms for immunogenic antibodies. These findings have implications for the preclinical immunogenicity risk assessment of biologics.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Formación de Anticuerpos/inmunología , Presentación de Antígeno/inmunología , Linfocitos T CD4-Positivos/inmunología , Células Dendríticas/inmunología , Activación de Linfocitos/inmunología , Anticuerpos Monoclonales/farmacología , Formación de Anticuerpos/efectos de los fármacos , Presentación de Antígeno/efectos de los fármacos , Linfocitos T CD4-Positivos/citología , Linfocitos T CD4-Positivos/efectos de los fármacos , Linfocitos T CD8-positivos/citología , Linfocitos T CD8-positivos/efectos de los fármacos , Linfocitos T CD8-positivos/inmunología , Proliferación Celular/efectos de los fármacos , Células Cultivadas , Células Dendríticas/efectos de los fármacos , Humanos , Leucocitos Mononucleares/citología , Leucocitos Mononucleares/inmunología , Leucocitos Mononucleares/metabolismo , Activación de Linfocitos/efectos de los fármacos
19.
Zhongguo Dang Dai Er Ke Za Zhi ; 11(9): 761-4, 2009 Sep.
Artículo en Zh | MEDLINE | ID: mdl-19755029

RESUMEN

OBJECTIVE: To construct a recombination retroviral expression vector pLNC-IL-4RA with high efficiency transfection and carrying a screening label. METHODS: IL-4RA was inserted into retroviral vector pLNC-Laz to get recombination retroviral expression vector pLNC-IL-4RA and then transfected into packaging cell line PA317 by liposome transfection. The transfected PA317 cells were obtained and amplified by G418 pressure screening. The cell culture supernatants containing viruses were harvested and the viral titer was determined by NIH3T3 cells infection. RESULTS: The G418 resistant clones were titrated and checked for the presence of replication virus. The results showed that the highest titer of viral supernatant was 1 x 10(4) CFU/mL. Genome DNA isolated from the cell clone of the highest titer showed the function gene, IL-4RA cDNA, had integrated into the genome of host cells verified by PCR. CONCLUSIONS: The recombination retroviral vector pLNC-IL-4RA encoding IL-4RA after packaging PA317 cells have higher viral titer. This provides a basis for gene treatment of asthma.


Asunto(s)
Vectores Genéticos/genética , Receptores de Interleucina-4/antagonistas & inhibidores , Retroviridae/genética , Transfección , Ensamble de Virus , Asma/terapia , Terapia Genética , Humanos , Reacción en Cadena de la Polimerasa
20.
MAbs ; 11(6): 1175-1190, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31181988

RESUMEN

We describe a bispecific dual-antagonist antibody against human B cell activating factor (BAFF) and interleukin 17A (IL-17). An anti-IL-17 single-chain variable fragment (scFv) derived from ixekizumab (Taltz®) was fused via a glycine-rich linker to anti-BAFF tabalumab. The IgG-scFv bound both BAFF and IL-17 simultaneously with identical stoichiometry as the parental mAbs. Stability studies of the initial IgG-scFv revealed chemical degradation and aggregation not observed in either parental antibody. The anti-IL-17 scFv showed a high melting temperature (Tm) by differential scanning calorimetry (73.1°C), but also concentration-dependent, initially reversible, protein self-association. To engineer scFv stability, three parallel approaches were taken: labile complementary-determining region (CDR) residues were replaced by stable, affinity-neutral amino acids, CDR charge distribution was balanced, and a H44-L100 interface disulfide bond was introduced. The Tm of the disulfide-stabilized scFv was largely unperturbed, yet it remained monodispersed at high protein concentration. Fluorescent dye binding titrations indicated reduced solvent exposure of hydrophobic residues and decreased proteolytic susceptibility was observed, both indicative of enhanced conformational stability. Superimposition of the H44-L100 scFv (PDB id: 6NOU) and ixekizumab antigen-binding fragment (PDB id: 6NOV) crystal structures revealed nearly identical orientation of the frameworks and CDR loops. The stabilized bispecific molecule LY3090106 (tibulizumab) potently antagonized both BAFF and IL-17 in cell-based and in vivo mouse models. In cynomolgus monkey, it suppressed B cell development and survival and remained functionally intact in circulation, with a prolonged half-life. In summary, we engineered a potent bispecific antibody targeting two key cytokines involved in human autoimmunity amenable to clinical development.


Asunto(s)
Anticuerpos Biespecíficos , Enfermedades Autoinmunes/tratamiento farmacológico , Factor Activador de Células B/antagonistas & inhibidores , Interleucina-17/antagonistas & inhibidores , Anticuerpos de Cadena Única , Animales , Anticuerpos Biespecíficos/inmunología , Anticuerpos Biespecíficos/farmacología , Anticuerpos Monoclonales Humanizados/inmunología , Anticuerpos Monoclonales Humanizados/farmacología , Enfermedades Autoinmunes/inmunología , Enfermedades Autoinmunes/patología , Factor Activador de Células B/inmunología , Femenino , Células HEK293 , Células HT29 , Humanos , Interleucina-17/inmunología , Macaca fascicularis , Ratones , Ratones Transgénicos , Anticuerpos de Cadena Única/inmunología , Anticuerpos de Cadena Única/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA