Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38647070

RESUMEN

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Técnicas de Sutura , Humanos , Fibrilación Atrial/cirugía , Femenino , Masculino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estudios Prospectivos , Venas Pulmonares/cirugía , Técnicas de Sutura/efectos adversos , Anciano , Resultado del Tratamiento , Alemania , Factores de Tiempo , Dispositivos de Cierre Vascular , Ambulación Precoz , Técnicas Hemostáticas/instrumentación
2.
J Cardiovasc Electrophysiol ; 34(1): 153-165, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36434795

RESUMEN

The last three decades have been characterized by an exponential increase in knowledge and advances in the clinical management of atrial fibrillation. The purpose of the study is to provide an overview of the pathogenesis of nonvalvular atrial fibrillation and a comprehensive investigation of the epidemiological data associated with various risk factors for atrial fibrillation. The leading research methods are analysis and synthesis, comparison, observation, induction and deduction, and grouping method. Research has shown that old age, male gender, and European descent are important risk factors for developing atrial fibrillation. Other modifiable risk factors include a sedentary lifestyle, smoking, obesity, diabetes mellitus, obstructive sleep apnea, and high blood pressure predisposing to atrial fibrillation, and each has been shown to induce structural and electrical atrial remodeling. Both heart failure and myocardial infarction increase the risk of developing atrial fibrillation and vice versa creating feedback that increases mortality. The review is a comprehensive study of the epidemiological data linking nonmodifiable and modifiable risk factors for atrial fibrillation, and the pathophysiological data supporting the relationship between each risk factor and the occurrence of atrial fibrillation. This may be necessary for the practice of the treatment of the cardiac system.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Hipertensión , Masculino , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Factores de Riesgo , Obesidad/complicaciones , Hipertensión/epidemiología , Atrios Cardíacos
3.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37470443

RESUMEN

AIMS: Electro-anatomical mapping may be critical to identify atrial fibrillation (AF) subjects who require substrate modification beyond pulmonary vein isolation (PVI). The objective was to determine correlations between pre-ablation mapping characteristics and 12-month outcomes after a single PVI-only catheter ablation of AF. METHODS AND RESULTS: This study enrolled paroxysmal AF (PAF), early persistent AF (PsAF; 7 days-3 months), and non-early PsAF (>3-12 months) subjects undergoing de novo PVI-only radiofrequency catheter ablation. Sinus rhythm (SR) and AF voltage maps were created with the Advisor HD Grid™ Mapping Catheter, Sensor Enabled™ for each subject, and the presence of low-voltage area (LVA) (low-voltage cutoffs: 0.1-1.5 mV) was investigated. Follow-up visits were at 3, 6, and 12 months, with a 24-h Holter monitor at 12 months. A Cox proportional hazards model identified associations between mapping data and 12-month recurrence after a single PVI procedure. The study enrolled 300 subjects (113 PAF, 86 early PsAF, and 101 non-early PsAF) at 18 centres. At 12 months, 75.5% of subjects were free from AF/atrial flutter (AFL)/atrial tachycardia (AT) recurrence. Univariate analysis found that arrhythmia recurrence did not correlate with AF diagnosis, but LVA was significantly correlated. Low-voltage area (<0.5 mV) >28% of the left atrium in SR [hazard ratio (HR): 4.82, 95% confidence interval (CI): 2.08-11.18; P = 0.0003] and >72% in AF (HR: 5.66, 95% CI: 2.34-13.69; P = 0.0001) was associated with a higher risk of AF/AFL/AT recurrence at 12 months. CONCLUSION: Larger extension of LVA was associated with an increased risk of arrhythmia recurrence. These subjects may benefit from substrate modification beyond PVI.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Frecuencia Cardíaca , Resultado del Tratamiento , Técnicas Electrofisiológicas Cardíacas , Recurrencia , Factores de Tiempo , Atrios Cardíacos , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Aleteo Atrial/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
4.
Europace ; 25(2): 374-381, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36414239

RESUMEN

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodos , Nervio Frénico , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
5.
Bratisl Lek Listy ; 124(2): 121-127, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36598298

RESUMEN

The relevance of the study is conditioned by the problem of implantation of an artificial cardiac pacemaker in atrial fibrillation in patients with tachy-brady syndrome according to the standard scheme related to the presence of a congenital anomaly, such as persistent left superior vena cava. The purpose of the study is to develop an operative method of implantation of a permanent two-chamber pacemaker in patients with tachy-brady syndrome with concomitant pathology of the persistent left superior vena cava. Research methods are the generally accepted clinical and instrumental examination of the patient, including taking anamnesis and a standard cardiological examination, electrocardiography, transthoracic echocardiography, plain radiography, angiocardiographic examination, and multispiral computed tomography, which, along with a general analysis, confirm the presence of tachy-brady syndrome with atrial fibrillation and congenital anomaly in the form of persistent left superior vena cava in patients. The study presents a developed model of surgical implantation of a permanent two-chamber pacemaker to stabilise the condition of patients with atrial fibrillation related to tachy-brady syndrome with concomitant persistent left superior vena cava; the standard implantation mechanism included the introduction of a radiopaque agent to clarify the anatomical structure of the vascular bed, further, its entry from the subclavian veins into the persistent left superior vena cava and into the cavity of the right atrium through the venous coronary sinus was detected, and then a gradual introduction of an endocardial right ventricular electrode was performed into the subclavian vein through the tricuspid valve along with its further positioning in the apex of the right ventricle; therefore, a permanent two-chamber pacemaker can be successfully installed, creating conditions for restoring sinus rhythm in this group of patients, which is of practical importance for the field of medicine (Tab. 3, Fig. 4, Ref. 20). Keywords: atrial fibrillation, persistent left superior vena cava, sick sinus syndrome, pacemaker implantation, cardiac surgery.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Vena Cava Superior Izquierda Persistente , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Síndrome del Seno Enfermo/terapia , Vena Cava Superior/anomalías , Bradicardia , Taquicardia
6.
J Cardiovasc Electrophysiol ; 33(8): 1678-1686, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35615939

RESUMEN

INTRODUCTION: Focal Impulse and Rotor Modulation (FIRM) guided catheter ablation aiming at stable rotors has been investigated as a treatment option in patients with atrial fibrillation (AF). The objective of this study was to compare the safety and efficacy of FIRM-guided ablation with second-generation cryoballoon pulmonary vein isolation (CB2-PVI) in paroxysmal AF. METHODS: Consecutive patients (n = 22, mean age 60 ± 11 years, 59.1% of males) who were treated with a stand-alone FIRM-guided ablation were included in this retrospective single-center study. Procedural data and arrhythmia-free survival at 12 months were compared with n = 86 consecutive patients (mean age 62 ± 13 years, 62.4% of males) who received de-novo CB2-PVI. RESULTS: Median procedure duration was significantly longer in the FIRM group than in the CB2-PVI group (152 [IQR 120-176] minutes vs. 122 [110-145] minutes; p = .031). One patient (1.2%) in the CB2-PVI group and five patients (22.7%) in the FIRM group had vascular access complications. Atrial tachyarrhythmias recurred in 15 patients in the FIRM group and 11 in the CB2-PVI group. Kaplan-Meier estimation of single-procedure arrhythmia-free survival at 12 months was 25% (95% confidence interval [CI] 6%-44%) in the FIRM group and 87% (95% CI 78%-96%) in the CB2-PVI group (p < .001). Repeat ablations were performed in 14/20 (70.0%) patients in the FIRM group and in 12/85 (14.1%) in the CB2-PVI group (p < .001). CONCLUSION: De novo ablation of AF using FIRM-guided AF ablation results in shorter arrhythmia-free survival after 12 months compared to CB2-PVI and a need for repeat ablation in the majority of patients to achieve stable sinus rhythm.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
7.
Internist (Berl) ; 62(11): 1174-1179, 2021 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-34591130

RESUMEN

Atrial fibrillation and heart failure with preserved left ventricular (LV) ejection fraction (HFpEF) are of high importance in cardiology due to the increasing number of cases. Both diseases can mutually affect each other and important cardiovascular risk factors, e.g. arterial hypertension, diabetes mellitus, obesity and chronic renal insufficiency can be observed with increasing frequency. Currently proven treatment concepts for patients with heart failure and reduced ejection fraction (HFrEF) do not appear to have a comparable prognostic or symptomatic benefit for patients with HFpEF. In addition, there are indications that de novo manifestation of atrial fibrillation in HFpEF patients has been linked to reduced survival. Also, heart and kidney function are negatively affected by atrial fibrillation. Retrospective analyses of patients with HFpEF and atrial fibrillation who had been treated by pulmonary vein isolation could show that interventional treatment of the atrial fibrillation led to an improvement in the New York Heart Association (NYHA) stage and diastolic function. Currently running prospective randomized clinical trials, such as the AMPERE study including patients with HFpEF and atrial fibrillation undergoing pulmonary vein isolation, will hopefully provide reliable prospective randomized data and possibly show an improved symptom control and perhaps also prognostically relevant treatment for HFpEF patients with atrial fibrillation.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Fenotipo , Estudios Prospectivos , Estudios Retrospectivos , Volumen Sistólico
8.
Circ J ; 82(11): 2722-2727, 2018 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-30197409

RESUMEN

BACKGROUND: Key determinants for lesion formation in catheter ablation are contact force, radiofrequency (RF) power and time. The aim of this study was to evaluate the clinical applicability of ablation index (AI), a novel non-linear formula based on these components, and to compare AI with the conventional linear force-time interval (FTI) in pulmonary vein isolation (PVI). Methods and Results: Target AI ranges were defined for anatomical segments of the ipsilateral pulmonary veins. The operator was blinded to AI during PVI for the initial 11 patients (group A), and was unblinded for the remaining 23 patients (group B). We assessed (1) the clinical value of AI to avoid excessively high and low values with an operator blinded vs. non-blinded to AI; and (2) the relation of AI and FTI in predefined ranges. In group A, 235/564 lesions (41.7%) were in the predefined target range as compared with 1,171/1,412 lesions (82.9%) in group B (P<0.001). A given AI may correspond to a wide range of FTI, as reflected by a quartile coefficient of dispersion for AI of 0.11 vs. a quartile coefficient of dispersion for FTI of 0.36. CONCLUSIONS: Incorporating RF current power, the non-linear AI provides more comprehensive information during PVI compared with FTI. Given that the FTI for a given AI varies widely, the value of FTI in clinical practice is questionable.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/patología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/patología , Venas Pulmonares/fisiopatología
9.
Pacing Clin Electrophysiol ; 41(6): 611-619, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29566268

RESUMEN

AIMS: Radiofrequency catheter ablation of atrial fibrillation (AF) is one of the most complex ablation procedures. Both patients and operators are exposed to scattered radiation. This study evaluated the safety and efficacy of intracardiac echo (ICE)-guided pulmonary vein isolation (PVI) without fluoroscopy. METHODS: We retrospectively analyzed the data of 481 consecutive patients with paroxysmal AF undergoing radiofrequency PVI with the CARTO 3 system (Biosense Webster, Diamond Bar, CA, USA). ICE-guided PVI without fluoroscopy and without CT/MRI integration (Nonfluoro group) was performed for 245 patients, and conventional fluoroscopy-guided PVI (Fluoro group) was performed for 236 patients. The primary safety endpoint was the incidence of major adverse events. The primary efficacy endpoint was freedom from AF during follow-up. Secondary endpoints included procedure duration, fluoroscopy duration, and acute PVI rate. RESULTS: Mean procedure times between groups were similar (108.8 ± 18.2 minutes in the Non-fluoro group vs 113.6 ± 26.8 minutes in the Fluoro group; P  =  not significant [NS]). Acute PVI was achieved in all patients, with mean radiofrequency application times of 43.4 ± 7.5 and 44.4 ± 10.7 minutes for the Nonfluoro and Fluoro groups, respectively (P  =  NS). The incidence of cardiac tamponade was 1.2% (3/245 patients) in the Nonfluoro group and 0.8% (2/236 patients) in the Fluoro group (P  =  NS). During 15.2 ± 4.1 months of follow-up, after a single procedure, AF recurrence was documented in 65 of 245 (26.5%) patients and 61 of 236 (25.8%) patients in the Nonfluoro and Fluoro groups, respectively (P  =  NS). CONCLUSIONS: Nonfluoroscopic ICE-guided catheter ablation of AF without prior cardiac image integration or angiography is feasible and safe. PVI without fluoroscopy did not affect procedure duration or long-term efficacy.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Administración de la Seguridad , Ablación por Catéter/efectos adversos , Mapeo Epicárdico , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Exposición a la Radiación , Estudios Retrospectivos , Resultado del Tratamiento
10.
Eur Heart J Case Rep ; 8(2): ytae048, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38332919

RESUMEN

Background: In patients with a total cavopulmonary connection in Fontan circulation, the access to the common atrium (CA) during a catheter ablation can be challenging, even in the presence of fenestration in an intra-atrial lateral tunnel (IALT). In our department, the fenestration is typically marked with metal clips (MCs). To the best of our knowledge, there is no previous report of balloonoplasty of clipped fenestration. Case summary: A 19-year-old male with hypoplastic left heart syndrome (HLHS) was scheduled for catheter ablation of recurrent atrial tachycardia. He was diagnosed with HLHS prenatally and underwent a stepwise surgical palliation. Fontan circulation was completed with the creation of a fenestrated IALT. The fenestration was marked by four MCs. During the ablation procedure, the passage of the steerable sheath with mapping catheter to the CA was prevented by a small fenestration size and rigidness of the edges of the fenestration caused by the MCs. Multiple attempts to dilate the fenestration using a peripheric angioplasty balloon failed. Only angioplasty with the 'balloon-against-dilator' technique was finally successful. Activation map showed a counterclockwise atrial flutter in the CA; successful ablation was performed. Discussion: We present a case of challenging access to the CA through a clipped fenestration in a polytetrafluoroethylene baffle for atrial tachycardia ablation. Even though a tunnel fenestration in Fontan patients facilitates access to the CA, the passage of a steerable introducer with a mapping catheter may be challenging due to diameter mismatch and the rigidity of its edges caused by MCs. The balloon-against-dilator technique might be helpful when conventional balloon angioplasty fails.

11.
Am J Cardiol ; 166: 53-57, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34973688

RESUMEN

Pulmonary vein (PV) automaticity is an established trigger for paroxysmal atrial fibrillation (PAF), making PV isolation (PVI) the cornerstone of catheter ablation. However, data on triggers for atrial fibrillation (AF) and catheter ablation strategy in very young patients aged <30 years are sparse. A total of 51 young patients (mean age 24.0 ± 4.2 years, 78.4% men) with drug-refractory PAF underwent electrophysiology (EP) study and ablation at 5 EP centers. None of the patients had structural heart disease or family history of AF. EP study induced supraventricular tachycardia (SVT) in 12 patients (n = 12, 23.5%): concealed accessory pathway mediated orthodromic atrioventricular reentrant tachycardia in 3 patients, typical atrioventricular nodal reentrant tachycardia in 6 patients, left superior PV tachycardia in 1 patient, left atrial appendage tachycardia in 1 patient, and typical atrial flutter in 1 patient. In patients with induced SVTs, SVT ablation without PVI was performed as an index procedure, except for the patient with atrial flutter who received cavotricuspid isthmus ablation in addition to PVI. Remaining patients underwent radiofrequency (n = 15, 29.4%) or second-generation cryoballoon-based PVI (n = 24, 47%). There were no major complications related to ablation procedures. Follow-up was based on outpatient visits including 24-hour Holter-electrocardiogram at 3, 6, and 12 months after ablation, or additional Holter-electrocardiogram was ordered in case of symptoms suggesting recurrence. Recurrence was defined as any atrial tachyarrhythmia (ATA) episode >30 seconds after a 3-month blanking period. A total of 2 patients with atrioventricular nodal reentrant tachycardia, 1 with left atrial appendage tachycardia, experienced AF recurrence within the first 3 months and received PVI. After the 3-month blanking period, during a median follow-up of 17.0 ± 10.1 months, 44 of 51 patients (86.2%) were free of ATA recurrence. In the PVI group, 33 of 39 patients (84.6%) experienced no ATA recurrence. In conclusion, SVT substrate is identified in around a quarter of young adult patients with history of AF, and targeted ablation without PVI may be sufficient in the majority of these patients. PVI is needed in the majority and is safe and effective in this population.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Paroxística , Taquicardia Supraventricular , Adulto , Fibrilación Atrial/diagnóstico , Criocirugía/métodos , Femenino , Humanos , Masculino , Venas Pulmonares/cirugía , Recurrencia , Taquicardia , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Taquicardia Paroxística/cirugía , Resultado del Tratamiento , Adulto Joven
12.
Circ Arrhythm Electrophysiol ; 15(1): e010516, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34962134

RESUMEN

BACKGROUND: Cryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce. METHODS: The YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible. RESULTS: A total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was -49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months. CONCLUSIONS: The incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03645577. Graphic Abstract: A graphic abstract is available for this article.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Enfermedad Iatrogénica , Traumatismos de los Nervios Periféricos/epidemiología , Nervio Frénico/lesiones , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Traumatismos de los Nervios Periféricos/diagnóstico , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
14.
Arrhythm Electrophysiol Rev ; 8(3): 173-179, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31463054

RESUMEN

Catheter ablation of ventricular tachycardia (VT) aims to treat the underlying arrhythmia substrate to prevent ICD therapies. The aim of this meta-analysis was to assess the safety and efficacy of VT ablation prior to or at the time of secondary prevention ICD implantation in patients with coronary artery disease, as compared with deferred VT ablation. Based on a systematic literature search, three randomised trials were considered eligible for inclusion in this analysis, and data on the number of patients with appropriate ICD shocks, appropriate ICD therapy, arrhythmic storm, death and major complications were extracted from each study. On pooled analysis, there was a significant reduction of appropriate ICD shocks (OR 2.58; 95% CI [1.54-4.34]; p<0.001) and appropriate ICD therapies (OR 2.04; 95% CI [1.15-3.61]; p=0.015) in patients undergoing VT ablation at the time of ICD implantation without significant differences with respect to complications (OR 1.39; 95% CI [0.43-4.51]; p=0.581). Mortality did not differ between both groups (OR 1.30; 95% CI [0.60-2.45]; p=0.422). Preventive catheter ablation of VT in patients with coronary heart disease at the time of secondary prevention ICD implantation results in a significant reduction of appropriate ICD shocks and any appropriate ICD therapy compared with patients without or with deferred VT ablation. No significant difference with respect to complications or mortality was observed between both treatment strategies.

15.
J Cardiol ; 73(6): 497-506, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30878353

RESUMEN

BACKGROUND: Data regarding atrial tachycardia (AT) following second-generation cryoballoon ablation (CBA) of atrial fibrillation (AF) are limited. AIM: To describe the incidence, mechanisms, and clinical predictors of ATs following CBA. METHODS AND RESULTS: In this retrospective single-center study 238 patients undergoing CBA for treatment of paroxysmal (91/238; 38.2%) or persistent AF were analyzed. During a mean follow-up of 11.9 ± 5.5 months recurrence of AF occurred in 49/238 patients (20.6%) and AT in 27/238 (11.3%). Twenty-six patients with AT and 14 with AF only underwent a redo ablation. The prevailing mechanism of AT was macroreentry [typical atrial flutter (AFL) (n = 10), left atrial macroreentry (n = 14), focal left-AT (n = 2)]. Non-cavotricuspid-isthmus-dependent macroreentry right-AT was mapped and ablated in 3 patients after initial AFL ablation. In a multivariate regression model, persistent type of AF (HR = 3.3; CI = 1.2-9.4), cardiomyopathy (HR = 3.5; CI = 1.5-8.4), treatment with beta-blockers (HR = 0.3; CI = 0.1-0.6), and pulmonary vein-abnormality (HR = 4.6; CI = 2.1-10.4) were independent predictors of AT. Substrate analysis revealed a significantly higher number of low voltage areas in the left atrium in patients with left-AT in comparison to patients with AF recurrence only (2.0; IQR=2.0-4.0 vs. 0.5; IQR = 0.0-2.25; p = 0.005). CONCLUSION: In this study, AT after CBA occurred in 11.3% of patients with macroreentry being the prevalent mechanism. All patients with left-AT presented with low voltage areas in the left atrium, suggesting a more progressive underlying fibrotic disease in these patients.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Complicaciones Posoperatorias/etiología , Taquicardia Supraventricular/etiología , Antagonistas Adrenérgicos beta/uso terapéutico , Apéndice Atrial/fisiopatología , Fibrilación Atrial/fisiopatología , Aleteo Atrial/fisiopatología , Ablación por Catéter/instrumentación , Criocirugía/instrumentación , Femenino , Atrios Cardíacos/fisiopatología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Prevalencia , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Supraventricular/epidemiología , Factores de Tiempo , Resultado del Tratamiento
16.
Clin Res Cardiol ; 108(2): 167-174, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30187178

RESUMEN

BACKGROUND: Catheter ablation (CA) is an established therapy for treatment of atrial fibrillation (AF). However, data about AF ablation using the cryoballoon (CB) in the elderly population are sparse. The aim of this single center retrospective study is to evaluate the safety and efficacy of CB ablation in patients ≥ 75 years compared to patients < 75 years. METHODS AND RESULTS: Fifty-five consecutive patients aged ≥ 75 years (elderly group) were compared with 183 patients aged < 75 years (control group). All patients underwent pulmonary vein isolation (PVI) using the second-generation CB. The mean age in the elderly group was 78 ± 2.8 years and 60.8 ± 9.5 in the control group (p < 0.001). During 11.8 ± 5.4 months of follow-up, single procedure success rate for the elderly and the control group was 72.8 and 76%, respectively (p = 0.37). During redo ablation (n = 40), low-voltage areas in the LA were more frequently observed in elderly patients compared to the control group [1.0 (IQR 0-2.0) segments vs 2.0 (IQR 2.0-3.0) segments, respectively, p = 0.03]. The most common complication was transient phrenic nerve palsy, which only occurred in patients < 75 years (0 vs 7, p = 0.33). No severe complication such as procedure-related deaths, atrio-esophageal fistula, or cerebrovascular embolic events occurred. CONCLUSIONS: Our data strengthen the value of CB ablation for the treatment of AF as an effective and safe procedure in elderly patients, with similar success and complication rates when compared with a younger population.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/instrumentación , Factores de Edad , Anciano , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
Am J Case Rep ; 20: 810-815, 2019 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-31177265

RESUMEN

BACKGROUND Response to cardiac resynchronization therapy (CRT) is variable among patients. Extensive scar tissue burden has been characterized as a negative predictor of significant response. Whereas mid-term and long-term response has been thoroughly investigated in randomized clinical trials; however, little is known about acute hemodynamic effects of biventricular pacing. CASE REPORT We report a case of an elderly female patient with severe ischemic cardiomyopathy and a large anterior wall aneurysm, who received right ventricular and biventricular pacing during ablation of incessant pleomorphic ventricular tachycardia. During the procedure, biventricular pacing was associated with a 20% acute increase in systolic blood pressure compared to right ventricular pacing, although there was no acute or long-term effect on left ventricular function. CONCLUSIONS The acute hemodynamic effect of CRT in our patient suggests an effect of CRT even in patients with negative predictors of CRT response such as severe ischemic cardiomyopathy with a large aneurysm. Although no marked increase in left ventricular function might be observed, the acute effect of CRT might contribute to stabilization of heart failure in these patients.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Ablación por Catéter/métodos , Aneurisma Cardíaco/complicaciones , Hemodinámica/fisiología , Isquemia Miocárdica/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Anciano de 80 o más Años , Disnea/diagnóstico , Disnea/etiología , Electrocardiografía/métodos , Femenino , Aneurisma Cardíaco/diagnóstico por imagen , Aneurisma Cardíaco/cirugía , Humanos , Imagenología Tridimensional/métodos , Multimorbilidad , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/terapia , Pronóstico , Medición de Riesgo , Taquicardia Ventricular/diagnóstico por imagen , Resultado del Tratamiento
19.
Clin Res Cardiol ; 107(7): 570-577, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29492703

RESUMEN

BACKGROUND: The second-generation cryoballoon (CB) is increasingly used for treatment of persistent atrial fibrillation (AF). Data regarding the clinical outcome and mechanism of arrhythmia recurrence following persistent AF ablation using CB is sparse. In this study, we aimed to assess the efficacy of CB and mechanisms of atrial tachyarrhythmia (ATA) recurrence in patients with persistent AF. METHODS AND RESULTS: A total of 133 patients (66 ± 10 years, 60% male) with symptomatic persistent AF, who were scheduled for PVI using the second-generation CB were enrolled. Follow-up included 24 h Holter recording at 3, 6 and 12 months. Any documented episode of ATA lasting more than 30 s was considered as a recurrent arrhythmic event. All targeted veins were isolated (100%). Phrenic nerve palsy with recovery during follow-up occurred in six patients (4.5%), no patient experienced tamponade or a cerebrovascular event. During 12.6 ± 5.4 months of follow-up, 89/133 (67%) patients were free of ATA recurrences. Multivariable analysis revealed recurrence in the blanking period (HR 11.46, 0.95 CI 3.92-33.49, p < 0.001), presence of cardiomyopathy (HR 2.75, 0.95 CI 1.09-6.96, p = 0.032) and PV abnormality (HR 3.56, 0.95 CI 1.21-10.43, p = 0.021) as predictors for late recurrence. CONCLUSION: In patients with persistent AF, second-generation cryoballoon use is associated with an excellent safety profile and favorable outcomes. Arrhythmia recurrence during the blanking period, presence of cardiomyopathy and PV abnormality were independent predictors of long-term AF recurrence.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Criocirugía/instrumentación , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Distribución de Chi-Cuadrado , Criocirugía/efectos adversos , Supervivencia sin Enfermedad , Diseño de Equipo , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
20.
Int J Cardiol ; 272: 142-148, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-30170919

RESUMEN

Second generation cryoballoon (CB) has been shown to be effective for treatment of paroxysmal and persistent atrial fibrillation (AF). However, the fixed size of the non-compliant balloon may limit its use in patients with pulmonary vein (PV) abnormalities. In this study we investigated the acute success, procedural complications and long term outcome of CB based PV isolation (PVI) in patients with PV abnormality. A total of 238 patients [64.8 ±â€¯11.1 years; 91 paroxysmal (38.2%), 147 persistent AF (61.8%)] underwent PVI using the second generation CB without preprocedural imaging. In 43/238 (18.1%) patients PV abnormality (left common PV in 26, right middle PV in 20) was observed. All targeted veins including abnormal PVs were isolated (100%). Transient phrenic nerve palsy (PNP) occurred in one (2.3%) patient in the PV anomalous group and 6 (3.0%) in the control group (p = NS). There was no other adverse event including PV stenosis, atrio-esophageal fistula or cerebrovascular events related to the procedure. During mean follow-up of 11.8 ±â€¯5.4 month a total of 59 patients (24.7%) had atrial tachyarrhythmia (ATA) recurrence [27 (11.3%) had AT recurrence]. In the PV anomalous group, 20/43 (46.5%) patients had ATA recurrence compared to 39/195 (20%) in the control group (p < 0.001). AT recurrence was observed in 27 (11.3) patients [11 (25.5%) in the PV anomalous group and 16 (8.2%) in controls respectively, p = 0.003]. In patients with PV abnormality CB-based AF ablation results in a similar acute PVI rate but a higher ATA recurrence rate during follow up as compared to patients without PV abnormality.


Asunto(s)
Ablación por Catéter/tendencias , Criocirugía/tendencias , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Reoperación/tendencias , Anciano , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Ecocardiografía/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA