Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Radiologe ; 60(10): 943-948, 2020 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-32886159

RESUMEN

OBJECTIVE: In spring 2020 imaging findings of the lungs were found in several radiological practices and in outpatient clinic patients, which indicated acute or previous viral pneumonia. It was striking that many of the patients affected had only mild symptoms. In this case study it was investigated to what extent SARS-CoV­2 can cause lung involvement even with minor symptoms. MATERIAL AND METHODS: In this study five outpatient radiological centers and two inpatient hospitals in North Rhine-Westphalia and Baden-Württemberg in Germany were involved. The retrospective analysis included outpatients with radiologically detected viral pneumonia, who were examined in March or April 2020. The clinical symptoms were divided into severity levels 1-5 using a simplified clinical score. The lung images were evaluated with respect to features specific for COVID-19 . The presence of a SARS-CoV­2 infection was verified using PCR, antibody testing and/or typical computed tomography (CT) morphology. RESULTS: A total of 50 patients were included, all of whom had radiological signs of viral pneumonia. The majority had no or only few non-specific symptoms (26/50). This was followed by mild symptoms of a flu-like infection (17/50). Severe forms were rare in outpatients (7/50). Detection of COVID-19 was successful in 30/50 cases using PCR and in 4/50 cases using an antibody test. In 16/50 cases the diagnosis was based on typical CT criteria and on the typical COVID patient history. CONCLUSION: A SARS-CoV­2 infection leads to lung involvement more often than previously assumed, namely not only in severely ill hospitalized patients but also in cases with only mild or even non-specific symptoms.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus , Pandemias , Neumonía Viral , Atención Ambulatoria , COVID-19 , Alemania , Humanos , Inflamación , Pacientes Ambulatorios , Estudios Retrospectivos , SARS-CoV-2
2.
Int J Colorectal Dis ; 30(5): 683-90, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25694139

RESUMEN

BACKGROUND: Porcine models are well established for studying intestinal anastomotic healing. In this study, we aimed to clarify the anatomic differences between human and porcine small intestines. Additionally, we investigated the influences of longitudinal and circular sutures on human small intestine perfusion. METHODS: Intestines were obtained from human cadavers (n = 8; small intestine, n = 51) and from pigs (n = 10; small intestine, n = 60). Vascularization was visualized with mennige gelatin perfusion and high-resolution mammography. Endothelial cell density was analyzed with immunohistochemistry and factor VIII antibodies. We also investigated the influence of suture techniques (circular anastomoses, n = 19; longitudinal sutures, n = 15) on vascular perfusion. RESULTS: Only human samples showed branching of mesenteric vessels. Compared to the pig, human vessels showed closer connections at the entrance to the bowel wall (p = 0.045) and higher numbers of intramural anastomoses (p < 0.001). Porcine main vessels formed in multifilament-like vessel bundles and displayed few intramural vessel anastomoses. Circular anastomoses induced a circular perfusion defect at the bowel wall; longitudinal anastomoses induced significantly smaller perfusion defects (p < 0.001). Both species showed higher vascular density in the jejunum than in the ileum (p < 0.001). Human samples showed similar vascular density within the jejunum (p = 0.583) and higher density in the ileum (p < 0.001) compared to pig samples. CONCLUSION: The results showed significant differences between human and porcine intestines. The porcine model remains the standard for studies on anastomotic healing because it is currently the only viable model for studying anastomosis and wound healing. Nevertheless, scientific interpretations must consider the anatomic differences between humans and porcine intestines.


Asunto(s)
Intestino Delgado/anatomía & histología , Intestino Delgado/irrigación sanguínea , Arterias Mesentéricas/anatomía & histología , Venas Mesentéricas/anatomía & histología , Adulto , Anciano , Anciano de 80 o más Años , Anastomosis Quirúrgica/métodos , Angiografía/métodos , Animales , Biopsia con Aguja , Cadáver , Femenino , Humanos , Inmunohistoquímica , Mucosa Intestinal/irrigación sanguínea , Mucosa Intestinal/patología , Intestino Delgado/cirugía , Masculino , Arterias Mesentéricas/diagnóstico por imagen , Venas Mesentéricas/diagnóstico por imagen , Persona de Mediana Edad , Circulación Esplácnica/fisiología , Estadísticas no Paramétricas , Técnicas de Sutura , Porcinos
3.
Rheumatol Int ; 35(9): 1541-7, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25782584

RESUMEN

C-peptide has pro-atherogenic effects in animal models, and elevated C-peptide levels are associated with cardiovascular and all-cause mortality in patients undergoing coronary angiography. This cross-sectional study investigated the association between C-peptide serum levels and coronary artery calcification (CAC) in patients with rheumatoid arthritis (RA), a high-risk group for cardiovascular events. Fifty-four patients with RA were recruited from an arthritis outpatient department at the University Hospital in Aachen, Germany. CAC was measured by multi-slice CT scan, and blood samples were drawn from all patients for the analysis of C-peptide and other cardiovascular biomarkers. Mean serum levels of C-peptide (1.187 ± 0.771 vs 0.745 ± 0.481 nmol/L, p = 0.02), YKL-40, LDL cholesterol, and triglycerides were significantly higher in patients with CAC (n = 32, 59 %) compared to those without CAC (n = 22, 41 %). Univariate analysis revealed a significant association of C-peptide [OR 4.7, 95 % CI (1.1, 20.2)], YKL-40, triglycerides, hypertension, smoking, age, and male sex with the presence of CAC. After adjustment for body mass index, cholesterol, diabetes, adiponectin, calcium, and phosphate, C-peptide was still significantly associated with CAC in a multivariate logistic regression model. In conclusion, C-peptide serum levels are independently associated with the presence of CAC in patients with RA. These data suggest a potential role of C-peptide in cardiovascular disease in patients with RA.


Asunto(s)
Artritis Reumatoide/sangre , Péptido C/sangre , Calcinosis/sangre , Enfermedad de la Arteria Coronaria/sangre , Anciano , Artritis Reumatoide/complicaciones , Artritis Reumatoide/diagnóstico por imagen , Calcinosis/complicaciones , Calcinosis/diagnóstico por imagen , LDL-Colesterol/sangre , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Triglicéridos/sangre
4.
Eur Radiol ; 23(11): 3062-70, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23771601

RESUMEN

OBJECTIVES: To investigate simultaneous dual-isotope SPECT/CT with two differently radioisotope-labelled albumin-microsphere fractions for treatment planning of hepatic radioembolisation. METHODS: In addition to (99m)Technetium-labelled albumin microspheres (commercially available), we performed labelling with (111)Indium. Binding stability of (111)Indium-labelled microspheres was tested in vitro and in vivo in mice. Simultaneous dual-isotope SPECT/CT imaging was validated in an anthropomorphic torso phantom; subsequently, dual-isotope SPECT/CT was performed under in-vivo conditions in pigs (n = 3) that underwent transarterial injection of (99m)Technetium- and (111)Indium-labelled microspheres in the liver (right and left hepatic artery, respectively), in both kidneys and in the gluteal musculature. In total, n = 18 transarterial injections were performed. RESULTS: In-vitro testing and in-vivo studies in mice documented high binding stability for both (99m)Technetium-labelled and (111)Indium-labelled microsphere fractions. In phantom studies, simultaneous dual-isotope SPECT/CT enabled reliable separation of both isotopes. In pigs, the identified deposition of both isotopes could be accurately matched with intended injection targets (100 %, 18/18 intended injection sites). Furthermore, an incidental deposition of (99m)Technetium-labelled microspheres in the stomach could be correlated to the test injection into a right hepatic artery. CONCLUSION: Simultaneous dual-isotope SPECT/CT after transarterial injection with (99m)Technetium- and (111)Indium-labelled microspheres is feasible. Thus, it may offer additional, valuable information compared to single (99m)Technetium-labelled albumin examinations. KEY POINTS: • Simultaneous dual-isotope SPECT/CT with (111) In- and (99m) Tc-labelled albumin microspheres is feasible. • Differentiation of two microsphere fractions after transarterial injection is possible. • The origin of an extra-hepatic microsphere deposition can be correlated to the corresponding artery. • This technique could reduce the setup time for selective internal radiation treatment.


Asunto(s)
Quimioembolización Terapéutica/métodos , Radioisótopos de Indio , Neoplasias Hepáticas Experimentales/diagnóstico , Planificación de la Radioterapia Asistida por Computador/métodos , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Albúminas , Animales , Antineoplásicos/administración & dosificación , Quimioradioterapia , Femenino , Humanos , Radioisótopos de Indio/uso terapéutico , Neoplasias Hepáticas Experimentales/terapia , Ratones , Microesferas , Radiofármacos , Porcinos
5.
BMC Nephrol ; 14: 219, 2013 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-24112318

RESUMEN

BACKGROUND: Sclerostin is a Wnt pathway antagonist regulating osteoblast activity and bone turnover. Here, we assessed the potential association of sclerostin with the development of coronary artery (CAC) and aortic valve calcifications (AVC) in haemodialysis (HD) patients. METHODS: We conducted a cross-sectional multi-slice computed tomography (MS-CT) scanning study in 67 chronic HD patients (59.4 ± 14.8 yrs) for measurement of CAC and AVC. We tested established biomarkers as well as serum sclerostin (ELISA) regarding their association to the presence of calcification. Fifty-four adults without relevant renal disease served as controls for serum sclerostin levels. Additionally, sclerostin expression in explanted aortic valves from 15 dialysis patients was analysed ex vivo by immunohistochemistry and mRNA quantification (Qt-RT-PCR). RESULTS: CAC (Agatston score > 100) and any AVC were present in 65% and in 40% of the MS-CT patient group, respectively. Serum sclerostin levels (1.53 ± 0.81 vs 0.76 ± 0.31 ng/mL, p < 0.001) were significantly elevated in HD compared to controls and more so in HD patients with AVC versus those without AVC (1.78 ± 0.84 vs 1.35 ± 0.73 ng/mL, p = 0.02). Multivariable regression analysis for AVC revealed significant associations with higher serum sclerostin. Ex vivo analysis of uraemic calcified aortic valves (n = 10) revealed a strong sclerostin expression very close to calcified regions (no sclerostin staining in non-calcified valves). Correspondingly, we observed a highly significant upregulation of sclerostin mRNA in calcified valves compared to non-calcified control valves. CONCLUSION: We found a strong association of sclerostin with calcifying aortic heart valve disease in haemodialysis patients. Sclerostin is locally produced in aortic valve tissue adjacent to areas of calcification.


Asunto(s)
Proteínas Morfogenéticas Óseas/sangre , Calcinosis/sangre , Enfermedad de la Arteria Coronaria/sangre , Cardiopatías Congénitas/sangre , Enfermedades de las Válvulas Cardíacas/sangre , Fallo Renal Crónico/sangre , Fallo Renal Crónico/rehabilitación , Diálisis Renal , Proteínas Adaptadoras Transductoras de Señales , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Biomarcadores/sangre , Calcinosis/etiología , Enfermedad de la Arteria Coronaria/etiología , Estudios Transversales , Femenino , Marcadores Genéticos , Cardiopatías Congénitas/etiología , Enfermedades de las Válvulas Cardíacas/etiología , Humanos , Fallo Renal Crónico/complicaciones , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto , Adulto Joven
6.
Eur Radiol ; 22(8): 1789-96, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22460059

RESUMEN

OBJECTIVES: To implement a retrospective intrinsic landmark-based (ILB) gating protocol for contrast-enhanced ultrasound (CEUS) and to compare its efficiency to non-gated, manually gated and extrinsically gated CEUS. METHODS: CEUS of the liver was performed in healthy mice (n = 5) and in NEMO knockout mice with dysplastic livers (n = 5). In healthy animals, first-pass kinetics of non-specific microbubbles was recorded. Knockout mice were analysed regarding retention of VEGFR2-specific microbubbles. For retrospective gating, a landmark which showed respiratory movement was encircled as a region of interest (ROI). During inspiration, the signal intensity within the ROI altered, which served as gating signal. To evaluate the accuracy, non-gated, extrinsically gated and ILB-gated time-intensity curves were created. For each curve, descriptive parameters were calculated and compared to the gold standard (manual frame-by-frame gating). RESULTS: No significant differences in the variation of ILB- and extrinsically gated time-intensity curves from the gold standard were observed. Non-gated data showed significantly higher variations. Also the variation of molecular ultrasound data was significantly lower for ILB-gated compared to non-gated data. CONCLUSION: ILB gating is a robust and easy method to improve data accuracy in functional and molecular ultrasound liver imaging. This technique can presumably be translated to contrast-enhanced ultrasound examinations in humans. KEY POINTS: • Quantitative analysis of the uptake of contrast agents during ultrasound is complex. • Intrinsic landmark-based gating (ILB) offers a simple implementable method for motion correction. • Results using ILB-gating are comparable to extrinsic gating using external biomonitoring devices. • Functional and molecular imaging of mobile organs will benefit from ILB gating.


Asunto(s)
Ultrasonografía/métodos , Animales , Medios de Contraste/farmacología , Humanos , Imagenología Tridimensional/métodos , Hígado/patología , Ratones , Ratones Noqueados , Microburbujas , Reproducibilidad de los Resultados , Respiración , Técnicas de Imagen Sincronizada Respiratorias , Estudios Retrospectivos , Factores de Tiempo , Receptor 2 de Factores de Crecimiento Endotelial Vascular/metabolismo
7.
GMS Hyg Infect Control ; 17: Doc04, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35284207

RESUMEN

Background: Hospital staff have an increased risk of SARS-CoV-2 infection. It is thus necessary to monitor the situation because infected staff may in turn infect patients and their family members. Following the first wave of infection in the summer of 2020, the Rhine-Maas Hospital (RMK) provided all staff the opportunity to be tested for SARS-COV-2 via antibody testing. Methods: The tests were carried out from 19.6.2020 to 17.7.2020. The IgG antibody test qualitatively tested for SARS-CoV-2 antibodies via enzyme-linked immunosorbent assay (ELISA). An IgG titre of 0.8 IU/mL or more was considered positive. All staff who tested positive for SARS-CoV-2 by PCR testing after February 2020 were also included in the study. Occupational and non-occupational risk factors for infection were determined. Staff in the intensive care ward, the emergency depart-ment, or a SARS-CoV-2 ward ("corona ward") were predefined as having increased exposure. Odds ratios (OR) were calculated using logistical regression for occupational and private infection risk. Results: 903 staff members (58.9%) with complete data took part in the cross-sectional study. 52 staff members (5.8%) had a positive PCR test result in their medical history or tested positive in the IgG test. Around half of the infections (55%) were only detected by serological testing during the study. Staff with tasks classified as at-risk had an OR of 1.9 (95% CI 1.04-3.5) for infection. Risk factors also included private contacts to people infected with SARS-CoV-2 and holidays in risk areas. At the time of data collection, 11.5% of those with the disease reported that they had not yet fully recovered from COVID-19. Discussion: Following the first COVID-19 wave, 5.3% of staff at the RMK were infected. An increase in occupational infection risk was found even after controlling for non-occupational infection risks. This should be taken into account with regard to the recognition of COVID-19 as an occupational disease. Methods to improve protection against nosocomial transmissions should be considered.

8.
Artículo en Inglés | MEDLINE | ID: mdl-36141696

RESUMEN

Healthcare workers bear a high risk of infection during epidemics and pandemics such as the current SARS-CoV-2 pandemic. Various new vaccines have been approved. We investigated the influence of the time elapsed since vaccination, as well as of vaccination schema, on health workers' spike antibody levels following their second vaccination. Blood samples were obtained from employees working at a German hospital between August 2021 and December 2021 on average half a year (range 130-280 days) after their second vaccination. Levels of SARS-CoV-2-IgG antibodies (spike and nucleocapsid protein) were qualitatively detected via chemiluminescent immunoassays (CLIAs). A previous infection with SARS-CoV-2 was an exclusion criterion. In total, 545 persons were included in this cross-sectional study. Most participants (97.8%) showed elevated anti-spike concentrations. Anti-spike levels differed significantly among vaccination schemas. Repeated vector vaccinations resulted in lower protective antibody levels. Higher age levels, immunosuppression and a longer time period since the second vaccination resulted in lower anti-spike levels. Women's antibody levels were higher, but not significantly. Since anti-spike levels drop after vaccination, further boosters are required to increase immunoreactivity. If two vector vaccines have been administered, it is possible that an mRNA booster might increase the anti-spike level.


Asunto(s)
COVID-19 , Glicoproteína de la Espiga del Coronavirus , Anticuerpos Antivirales , COVID-19/prevención & control , Estudios Transversales , Femenino , Personal de Salud , Humanos , Inmunoglobulina G , Proteínas de la Nucleocápside , ARN Mensajero , SARS-CoV-2 , Vacunación , Proteínas del Envoltorio Viral/genética , Proteínas del Envoltorio Viral/metabolismo
9.
Radiology ; 260(3): 709-17, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21788527

RESUMEN

PURPOSE: To develop and evaluate a user-friendly tool to enable efficient, accurate, and reproducible quantification of blood vessel stenosis in computed tomographic (CT) and magnetic resonance (MR) angiographic data sets. MATERIALS AND METHODS: All clinical experiments were approved by the institutional review board, and informed patient consent was acquired. Animal experiments were approved by the governmental review committee on animal care. A virtual elastic sphere passes through a blood vessel specified by user-provided start and end points, and the adapting diameter over the course of the vessel is recorded. The program was tested in phantoms to determine the accuracy of diameter estimation, and it was applied in micro-CT data sets of mice with induced vessel stenosis. Dual-energy CT angiography and MR angiography were performed in 16 patients with carotid artery stenosis, and reproducibility and required reader time of this automated technique were compared with manual measurements. Additionally, the effect of dual-energy CT-based discrimination between iodine- and calcium-based enhancement was investigated. Differences between carotid artery diameters of mice and between automated and manual measurement durations were assessed with a paired t test. Reproducibility of stenosis scores was evaluated with the Fisher z test. RESULTS: Phantom diameters were determined with an average error of 0.094 mm. Diameters of normal and injured carotid arteries of mice were significantly different (P < .01). For patient data, automated interreader variability was significantly (P < .01) lower than manual intra- and interreader variability, while time efficiency was improved (P < .01). CONCLUSION: The virtual elastic sphere tool is applicable to CT, dual-energy CT, and MR angiography, and it improves reproducibility and efficiency over that achieved with manual stenosis measurements.


Asunto(s)
Angiografía Coronaria/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Animales , Femenino , Humanos , Masculino , Ratones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Eur Radiol ; 20(2): 469-76, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19697041

RESUMEN

Besides the assessment of carotid artery stenosis, evaluation of the vascular anatomy and lesions within both the extra- and intracranial arteries is crucial for proper clinical evaluation, treatment choice and planning. The purpose of our study was to evaluate the potential of dual-source CTA and 3T-MRA. In 16 symptomatic CAS patients, contrast-enhanced DSCT and 3T-MRA examinations were performed. For DSCT a dual-energy protocol with a 64 x 0.6-mm collimation was applied. In 3T-MRA intracranial high-resolution unenhanced TOF and extracranial contrast-enhanced MRA were performed. All examinations were analyzed for relevant morphologic and pathologic features or anomalies, and a total of 624 vessel segments were scored. All examinations were of diagnostic image quality with good to excellent vessel visibility. Almost all intracranial arteries were significantly better visualized by MRA compared to CTA (five of six vessels, p < 0.05). DSCT however allowed for further morphological carotid stenosis description, especially with respect to calcification. Although MRA proved to be superior in visualization of smaller intracranial arteries, all pre-interventionally relevant information could be perceived from DSCT. DSCT and MRA may both be regarded as a reliable, fast, pre-interventional imaging investigation in patients with carotid artery stenosis.


Asunto(s)
Estenosis Carotídea/diagnóstico , Angiografía Cerebral/métodos , Angiografía por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Eur Heart J ; 30(16): 2054-61, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19429630

RESUMEN

AIMS: Fetuin-A has been identified as a potent circulating inhibitor of ectopic calcification. We investigated the relationship between baseline fetuin-A serum levels and the rate of progression of aortic valve calcification (AVC) in non-dialyzed patients with aortic valve disease (AVD). METHODS AND RESULTS: Seventy-seven patients (mean age 70 +/- 8 years) with echocardiographically proven AVD were collected. In all patients, serum fetuin-A levels, creatinine, calcium, lipid parameters, and C-reactive protein were measured at baseline. For quantification of AVC progression, all patients underwent multislice spiral computed tomography examinations at baseline and after a mean follow-up of 12.6 +/- 1.4 months (range 7-18 months). In a multifactorial analysis of covariance including fetuin-A levels, baseline AVC score, the covariables sex, age, body mass index, C-reactive protein, glomerular filtration rate, serum lipids, diabetes, smoking status, and hypertension, only serum fetuin-A levels significantly predict the progression of AVC (P < 0.001). Post hoc analysis demonstrated that patients with baseline fetuin-A levels lower than the median of the cohort (0.72 g/L) showed a significantly higher increase of AVC scores (34.6 +/- 31.4%) than patients with fetuin-A levels larger than the median (10.0 +/- 11.2%, P < 0.001) despite comparable baseline AVC scores. In addition, fetuin-A levels were associated with major adverse clinical events (MACE; P = 0.03). CONCLUSION: Serum levels of the calcification inhibitor fetuin-A are associated with the progression of AVC and MACE, independent of the renal function and inflammation.


Asunto(s)
Enfermedades de la Aorta/diagnóstico , Válvula Aórtica , Proteínas Sanguíneas/metabolismo , Calcinosis/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Proteínas Sanguíneas/deficiencia , Angiografía Coronaria , Progresión de la Enfermedad , Ecocardiografía , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Tomografía Computarizada Espiral , alfa-2-Glicoproteína-HS
12.
Acta Cardiol ; 65(2): 161-70, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20458823

RESUMEN

OBJECTIVE: Cardiac resynchronization therapy (CRT) provides a therapeutic option for patients with congestive heart failure (CHF). There is evidence that the optimal pacing site (OIS) is vicinal to the region of the latest contraction (RLC). However, the RLC is not identified routinely to guide lead implantation to the coronary venous system (CVS). The aim of this study was: (i) to develop a software over-imposing CVS-anatomy on parametric images of left ventricular dyssynchrony in a 3D-format obtained from computed tomography (CT) and cardiac magnetic resonance imaging (MRI); and (ii) to apply this 3D-software for analysing the possible correlation between functional/ clinical improvement and the distance between final implantation site (FIS) and RLC. METHODS AND RESULTS: In 20 CHF-patients (11 men, 65.6 +/- 6.8 y, ejection fraction (EF): 27.5 +/- 6.1%) CRT-leads were implanted; follow-up included echocardiographic and exercise evaluation. The OIS and the FIS were noted on 3D-registrations and the distances OIS-RLC and FIS-RLC measured.The target vessel was reached in 14 cases. NYHA class and EF improved significantly with a low rate of non-responders of 3 (15%) (EF) and 4 (20%) (NYHA). Image registration was possible in all patients. Post-process 3D-analysis revealed no correlation between the distance FIS-RLC and functional or echocardiographic improvements.There was a trend towards a shorter distance FIS-RLC in patients classified as responders (EF). NYHA class improved significantly better in patients with target vessel implantation. CONCLUSIONS: Registration of CT/MRI-images enables efforts to reach the RLC by preoperative identification of corresponding veins. Larger randomized trials must define the definite therapeutic benefit.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Vasos Coronarios/patología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Imagenología Tridimensional , Imagen por Resonancia Magnética , Contracción Miocárdica , Marcapaso Artificial , Tomografía Computarizada por Rayos X , Anciano , Vasos Coronarios/fisiopatología , Ecocardiografía Doppler/métodos , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
13.
Thromb Haemost ; 101(2): 359-66, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19190822

RESUMEN

Matrix gamma-carboxyglutamate (Gla) protein (MGP) is a potent local inhibitor of cardiovascular calcification and accumulates at areas of calcification in its uncarboxylated form (ucMGP). We previously found significantly lower circulating ucMGP levels in patients with a high vascular calcification burden. Here we report on the potential of circulating ucMGP to serve as a biomarker for vascular calcification in haemodialysis (HD) patients. Circulating ucMGP levels were measured with an ELISA-based assay in 40 HD patients who underwent multi-slice computed tomography (MSCT) scanning to quantify the extent of coronary artery calcification (CAC). The mean ucMGP level in HD patients (193 +/- 65 nM) was significantly lower as compared to apparently healthy subjects of the same age (441 +/- 97 nM; p < 0.001) and patients with rheumatoid arthritis (RA) without CAC (560 +/- 140 nM; p < 0.001). Additionally, ucMGP levels correlated inversely with CAC scores (r = -0.41; p = 0.009), and this correlation persisted after adjustment for age, dialysis vintage and high-sensitivity C-reactive protein (hs-CRP). Since circulating ucMGP levels are significantly and inversely correlated with the extent of CAC in HD patients, ucMGP may become a tool for identifying HD patients with a high probability of cardiovascular calcification.


Asunto(s)
Calcinosis/sangre , Proteínas de Unión al Calcio/sangre , Enfermedad de la Arteria Coronaria/sangre , Proteínas de la Matriz Extracelular/sangre , Fallo Renal Crónico/terapia , Procesamiento Proteico-Postraduccional , Diálisis Renal , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Calcinosis/complicaciones , Calcinosis/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios Transversales , Regulación hacia Abajo , Ensayo de Inmunoadsorción Enzimática , Femenino , Alemania , Humanos , Fallo Renal Crónico/sangre , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Países Bajos , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X , Proteína Gla de la Matriz
14.
Eur Radiol ; 19(5): 1079-86, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19107487

RESUMEN

The purpose of this study was to assess the accuracy of automated nodal quantification in a phantom. MDCT of a phantom with 17 synthetic lymph nodes of different sizes (diameter 6.0-30.0 mm) was performed at varying tube currents, reconstruction kernels and slice thicknesses. RECIST diameter and volume were measured using an automated software tool. Results were compared with the reference diameter and volume by calculating the absolute percentage error (APE). Degree of agreement between software and reference measurements was evaluated by computing corresponding concordance correlation coefficients (CCC). Under varying tube currents the mean APE (CCC) varied between 5.18% and 10.12% (0.95-0.99) for RECIST diameter and between 7.22% and 16.21% (0.94-1.00) for the volume. At different reconstruction kernels the mean APE values ranged between 7.20% and 7.55% (0.99) (RECIST) and between 8.96% and 14.42% (1.00) (volume). With different slice thicknesses the mean APE values differed from 5.81% to 9.20% (0.97-0.99) (RECIST) and from 8.16% to 22.66% (0.99-1.00) (volume). Regarding RECIST criteria and volume, automated evaluation of lymph nodes in a phantom demonstrated a high accuracy under varying MDCT parameters.


Asunto(s)
Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Algoritmos , Automatización , Computadores , Humanos , Procesamiento de Imagen Asistido por Computador , Metástasis de la Neoplasia , Reconocimiento de Normas Patrones Automatizadas , Reproducibilidad de los Resultados , Programas Informáticos , Interfaz Usuario-Computador
15.
Acta Cardiol ; 64(3): 311-9, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19593940

RESUMEN

OBJECTIVE: Cardiac computed tomography (CT) and conventional biplane ventriculography are established methods for the determination of ventricular function. Recently dual source CT was introduced for cardiac CT scanning providing a temporal resolution of 83 ms independent of the patient's heart rate. The purpose of this study was to assess the global left ventricular function using retrospectively ECG-gated dual source computed tomography (DSCT) in comparison to conventional ventriculography. METHODS AND RESULTS: Contrast-enhanced cardiac DSCT and conventional ventriculography were performed in 10 domestic pigs with an approximate weight of 60 kg using standardized examination protocols under general anaesthesia. From manually drawn endocardial contours, LV end-systolic (ESV) and end-diastolic volume (EDV), stroke volume (SV), ejection fraction (EF) were calculated by means of dedicated analysis software separately for both examination modalities. LV functional parameters were analysed using Bland-Altman plots, Student t-test, and Pearson correlation coefficient. Left ESV and EDV determined with DSCT correlated well with conventional ventriculography results (ESV: r = 0.86; EDV: r = 0.72) with a good correlation also for SV (r = 0.67).An only moderate correlation was found for EF (r = 0.52). Student t-test showed a significant underestimation of SV and EF derived from DSCT in comparison to ventriculography. CONCLUSION: Retrospectively ECG-gated DSCT can accurately determine LV volumes in comparison to conventional ventriculography but provides lower SV and EF values; however, the correlation was only moderate.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico , Tomografía Computarizada por Rayos X , Función Ventricular Izquierda/fisiología , Animales , Gasto Cardíaco , Diástole , Modelos Animales de Enfermedad , Ventrículos Cardíacos/anomalías , Humanos , Estudios Retrospectivos , Estadística como Asunto , Porcinos , Sístole
16.
Radiology ; 246(2): 519-25, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18227544

RESUMEN

PURPOSE: To prospectively evaluate, in a phantom, the dose reductions achievable by using angular beam modulation (ABM) during computed tomographic (CT) fluoroscopy-guided thoracic interventions. MATERIALS AND METHODS: To enable measurement of organ doses and effective patient dose, a female Alderson-Rando phantom was equipped with thermoluminescent dosimeters (TLDs) in 41 positions, with three TLDs in each position. Additionally, the local dose was assessed in 22 locations above the phantom to estimate the radiation exposure to the radiologist's hand and the patient's skin dose during thoracic interventions. Radiation exposure was performed with a 64-section multidetector CT scanner in the CT fluoroscopy mode, simulating a CT fluoroscopy-guided chest intervention. Effective dose, breast dose, and the dose to the radiologist's hand during the simulated chest intervention were measured with and without ABM. Image noise as an indicator for image quality was compared for both settings. Statistical significance of the measured dose reductions and the image noise was tested by using the paired-samples t test, with P < .05 indicating a significant difference. RESULTS: ABM significantly reduced the effective patient dose by 35%, the skin dose by 75%, the breast dose by 47% (P < .001 for all), and the physician's hand dose by between 27% (scattered radiation, P = .007) and 72% (direct radiation, P < .001). No significant difference was found in a comparison of the image noise with and that without ABM. CONCLUSION: ABM leads to significant dose reductions for both patients and personnel during CT fluoroscopy-guided thoracic interventions, without impairing image quality.


Asunto(s)
Carga Corporal (Radioterapia) , Fluoroscopía/métodos , Aumento de la Imagen/métodos , Radiografía Intervencional/métodos , Radiografía Torácica/métodos , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Femenino , Fluoroscopía/instrumentación , Humanos , Fantasmas de Imagen , Dosis de Radiación , Radiografía Intervencional/instrumentación , Radiografía Torácica/instrumentación , Efectividad Biológica Relativa , Tomografía Computarizada por Rayos X/instrumentación
17.
Eur Radiol ; 18(12): 2826-32, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18651154

RESUMEN

In computed tomography (CT) several contrast media with different iodine concentrations are available. The aim of this study is to prospectively compare contrast media with iodine concentrations of 300, 370 and 400 mg iodine/ml for chest- CT. 300 consecutive patients were prospectively enrolled, under a waiver of the local ethics committee. The first (second, third) 100 patients, received contrast medium with 300 (370, 400) mg iodine/ml. Injection protocols were adapted for an identical iodine delivery rate (1.3 mg/s) and total iodine load (33 g) for all three groups. Standardized MDCT of the chest (16 x 0.75 mm, 120 kVp, 100 mAseff.) was performed. Intravascular attenuation values were measured in the pulmonary trunk and the ascending aorta; subjective image quality was rated on a 3-point-scale. Discomfort during and after injection was evaluated. There were no statistically significant differences in contrast enhancement comparing the three contrast media at the pulmonary trunk (p = 0.3198) and at the ascending aorta (p = 0.0840). Image quality (p = 0.0176) and discomfort during injection (p = 0.7034) were comparable for all groups. General discomfort after injection of contrast media with 300 mg iodine/ml was statistically significant higher compared to 370 mg iodine/ml (p = 0.00019). Given identical iodine delivery rates of 1.3 g/s and iodine loads of 33 g, contrast media with concentrations of 300, 370 and 400 mg iodine/ml do not result in different intravascular enhancement in chest-CT.


Asunto(s)
Medios de Contraste/administración & dosificación , Yohexol/análogos & derivados , Yopamidol/análogos & derivados , Radiografía Torácica/métodos , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Yohexol/administración & dosificación , Yopamidol/administración & dosificación , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
Eur Radiol ; 18(11): 2456-65, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18523775

RESUMEN

As semi-automated measurement would be desirable for lesion quantification and therapy-response control, the purpose of this study was to compare semi-automated measurements with manual assessment of different types of hepatic metastases. Seventy-six patients with known liver metastases were analysed. All of them underwent contrast-enhanced 16-MDCT (16 x 0.75 mm collimation, 120 kV, 0.5 s rotation time, 160 mAs(eff)) for evaluation of follow-up status. On the basis of standard reconstructed 5-mm slices (in 4-mm increments), each lesion was quantified based on RECIST and WHO criteria using a semi-automated software tool (Syngo Oncology) and also manually by an experienced radiologist. Results from the software were compared to manual measurements. Statistical analysis was performed applying the concordance correlation coefficient, and results were represented graphically in Bland-Altman plots. A total of 52 hyperdense, 57 hypodense and 56 heterogeneous metastases were found and correctly measured by the software. All three lesion types revealed a strong correlation agreement between measurement techniques [RECIST diameter: 0.93 (hyperdense), 0.95(hypodense), 0.94 (heterogeneous); WHO area: 0.95, 0.98, 0.93]. Semi-automatic measurement of hyperdense, hypodense and heterogeneous liver metastases showed reliable results on standard axial reconstructions in comparison to manual quantification.


Asunto(s)
Inteligencia Artificial , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/secundario , Neoplasias Hepáticas/diagnóstico por imagen , Reconocimiento de Normas Patrones Automatizadas/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Humanos , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Organización Mundial de la Salud
19.
AJR Am J Roentgenol ; 190(5): 1358-61, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18430855

RESUMEN

OBJECTIVE: The aim of this study was to compare ECG-gated 64-MDCT with MRI for the assessment of global right ventricular (RV) function from coronary CT angiography data. SUBJECTS AND METHODS: Thirty-eight patients (25 men, 13 women; mean age +/- SD, 55.0 +/- 8.8 years) with suspected coronary artery disease underwent contrast-enhanced 64-MDCT (64 x 0.6 mm, 120 kV, 770 mAs(eff)) and 1.5-T MRI (balanced fast-field echo; TR/TE, 3.3/1.6; flip angle, 60 degrees ; 50 phases). Double oblique short-axis MDCT and MR images were used for further analysis. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were computed from manually drawn endocardial contours of the right ventricle. For statistical analysis, repeated-measures analysis of variance and Pearson's correlation coefficients were calculated. Bland-Altman plots were computed. RESULTS: In general, RV volumes calculated from 64-MDCT agreed well with those calculated from MRI. The mean EF (+/- SD) calculated from MDCT and MRI was 51.0% +/- 7.8% and 51.4% +/- 7.3%, respectively. An excellent correlation was observed for EDV (r = 0.99), ESV (r = 0.98), SV (r = 0.98), and EF (r = 0.97). Bland-Altman plots showed no systematic variation between MDCT and MRI data. No statistically significant differences (p < or = 0.05) between the techniques were found. CONCLUSION: Although contrast injection is optimized for visualization of the coronary arteries, retrospectively ECG-gated 64-MDCT permits reliable assessment of global RV function.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Función Ventricular Derecha/fisiología , Medios de Contraste , Enfermedad de la Arteria Coronaria/patología , Electrocardiografía , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Yohexol/análogos & derivados , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Volumen Sistólico
20.
AJR Am J Roentgenol ; 191(1): 145-50, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18562738

RESUMEN

OBJECTIVE: The purpose of this study was an intraindividual comparison of the degrees of MDCT contrast enhancement achieved with agents containing 300 and 370 mg I/mL. SUBJECTS AND METHODS: Seventy-five patients underwent baseline and follow-up MDCT of the chest and abdomen with contrast media containing a high concentration of iodine (iopromide 370 mg I/mL) and standard iodine concentration (iopromide 300 mg I/mL). The total iodine load (37 g) and the iodine delivery rate (1.29 g/s) were identical for the two protocols. Contrast enhancement in the chest (right and left ventricles, pulmonary trunk, descending aorta) and the abdomen (aorta, inferior vena cava, portal vein, and liver) was determined. Results were compared by use of paired Student's t tests, and p was adjusted with Bonferroni correction for multiple comparisons (p 0.0056). CONCLUSION: Given equivalent iodine load and delivery rate, the use of 300 mg I/mL contrast medium results in better contrast enhancement than use of 370 mg I/mL contrast medium in CT of the chest. For the portal venous phase of CT of the abdomen, there was no significant difference in contrast enhancement for the two concentrations of iodine.


Asunto(s)
Medios de Contraste/administración & dosificación , Almacenamiento y Recuperación de la Información/métodos , Yohexol/análogos & derivados , Radiografía Abdominal/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Yohexol/administración & dosificación , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA