1.
Anaesthesia ; 79(9): 957-966, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38789407

RESUMEN

BACKGROUND: It is not certain whether the blade geometry of videolaryngoscopes, either a hyperangulated or Macintosh shape, affects glottic view, success rate and/or tracheal intubation time in patients with expected difficult airways. We hypothesised that using a hyperangulated videolaryngoscope blade would visualise a higher percentage of glottic opening compared with a Macintosh videolaryngoscope blade in patients with expected difficult airways. METHODS: We conducted an open-label, patient-blinded, randomised controlled trial in adult patients scheduled to undergo elective ear, nose and throat or oral and maxillofacial surgery, who were anticipated to have a difficult airway. All airway operators were consultant anaesthetists. Patients were allocated randomly to tracheal intubation with either hyperangulated (C-MAC D-BLADE™) or Macintosh videolaryngoscope blades (C-MAC™). The primary outcome was the percentage of glottic opening. First attempt success was designated a key secondary outcome. RESULTS: We assessed 2540 adults scheduled for elective head and neck surgery for eligibility and included 182 patients with expected difficult airways undergoing orotracheal intubation. The percentage of glottic opening visualised, expressed as median (IQR [range]), was 89 (69-99 [0-100])% with hyperangulated videolaryngoscope blades and 54 (9-90 [0-100])% with Macintosh videolaryngoscope blades (p < 0.001). First-line hyperangulated videolaryngoscopy failed in one patient and Macintosh videolaryngoscopy in 12 patients (13%, p = 0.002). First attempt success rate was 97% with hyperangulated videolaryngoscope blades and 67% with Macintosh videolaryngoscope blades (p < 0.001). CONCLUSIONS: Glottic view and first attempt success rate were superior with hyperangulated videolaryngoscope blades compared with Macintosh videolaryngoscope blades when used by experienced anaesthetists in patients with difficult airways.


Asunto(s)
Manejo de la Vía Aérea , Intubación Intratraqueal , Laringoscopios , Laringoscopía , Humanos , Laringoscopía/métodos , Laringoscopía/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Intubación Intratraqueal/instrumentación , Intubación Intratraqueal/métodos , Adulto , Manejo de la Vía Aérea/métodos , Manejo de la Vía Aérea/instrumentación , Anciano , Grabación en Video , Glotis , Diseño de Equipo , Método Simple Ciego , Procedimientos y Técnicas Asistidas por Video
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA