Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Pol J Radiol ; 87: e187-e193, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35505853

RESUMEN

Purpose: The primary objective was to assess the frequency of appropriateness of computed tomography (CT) for acute abdominal pain (AAP) in the emergency department; the secondary aim was to compare the diagnostic accuracy of ultra-sound (US) and CT in the diagnosis of the aetiology of AAP for diseases that can be diagnosed by US; and the third objective was to assess extent to which inappropriate CT examinations for AAP result in ionizing radiation exposure. Material and methods: In this retrospective single-centre study, we included patients aged between 15 and 46 years referred to the emergency department for AAP in 2016 and submitted to abdominal CT scans, collecting a total of 586 patients. In 152 patients with the more frequent pathologies, we compared the referral reason and current guidelines of the European Society of Radiology (ESR) IGUIDE®. Then we measured and compared the sensitivity of US and CT for the identification of the aetiology of AAP for diseases whose diagnosis can be reached by US. We also recorded the mean computed tomography dose index (CTDIvol), dose length product (DLP) and its standard deviation, and we calculated the effective dose (ED) using CT-Expo® software. Results: According to IGUIDE and based on the clinical suspicion of CT requests, CT examination was considered crucial in 264 (45.05%) patients. 322 patients had a referral reason for CT scan that could be considered "possibly appropriate" according Iguide criteria (4, 5, 6 scoring). Of these, 135 had an inappropriate CT request according to image findings. Conclusions: A better clinical framing and a correct interpretation of the reference guidelines could reduce unjustified exposure to ionizing radiation.

2.
Radiol Med ; 124(8): 762-767, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30848421

RESUMEN

OBJECTIVE: The aim of this study was to acknowledge errors in patients positioning in CT colonography (CTC) and their effect in radiation exposure. MATERIALS AND METHODS: CTC studies of a total of 199 patients coming from two different referral hospitals were retrospectively reviewed. Two parameters have been considered for the analysis: patient position in relation to gantry isocentre and scan length related to the area of interest. CTDI vol and DLP were extracted for each patient. In order to evaluate the estimated effective total dose and the dose to various organs, we used the CT-EXPO® software version 2.2. This software provides estimates of effective dose and doses to the other various organs. RESULTS: Average value of the patients' position is found to be below the isocentre for 48 ± 25 mm and 29 ± 27 mm in the prone and supine position. It was observed that the increase in CTDI and DLP values for patients in Group 1, due to the inaccurate positioning, was estimated at about 30% and 20% for prone and supine position, respectively, while in Group 2, a decrease in CTDI and DLP values was estimated at about 16% and 18% for prone and supine position, respectively, due to an average position above isocentre. A dose increase ranging from 4 up to 13% was calculated with increasing the over-scanned region below anal orifice. CONCLUSION: Radiographers and radiologists need to be aware of dose variation and noise effects on vertical positioning and over-scanning. More accurate training need to be achieved even so when examination protocol varies from general practice.


Asunto(s)
Colonografía Tomográfica Computarizada/efectos adversos , Errores Médicos/efectos adversos , Posicionamiento del Paciente/efectos adversos , Dosis de Radiación , Exposición a la Radiación , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Posicionamiento del Paciente/métodos , Posición Prona , Errores de Configuración en Radioterapia/efectos adversos , Estudios Retrospectivos , Posición Supina , Factores de Tiempo
3.
Radiat Environ Biophys ; 56(4): 471-480, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28929295

RESUMEN

This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076®) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose-response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the manufactured dosimeters was obtained. The ESR signal proved to increase linearly with increasing dose in the investigated dose range 1-13 Gy. The presence of an intrinsic background signal limits the minimum detectable dose to a value of approximately 0.6 Gy. Reliable and accurate assessment of the dose was achieved, independently of the dose rate. Such characteristics, together with the fact that IRGANOX 1076® is almost tissue-equivalent, and the stability of the ESR signal, make these dosimeters promising materials for ESR dosimetric applications in radiotherapy.


Asunto(s)
Fenoles/química , Fotones/uso terapéutico , Radiometría/métodos , Espectroscopía de Resonancia por Spin del Electrón , Microondas , Modelos Moleculares , Conformación Molecular , Dosificación Radioterapéutica
4.
Radiol Med ; 121(2): 144-52, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26387096

RESUMEN

Multidetector computed tomography (MDCT) represents the main source of radiation exposure in trauma patients. The radiation exposure of young patients is a matter of considerable medical concern due to possible long-term effects. Multiple MDCT studies have been observed in the young trauma population with an increase in radiation exposure. We have identified 249 young adult patients (178 men and 71 women; age range 14-40 years) who had received more than one MDCT study between June 2010 and June 2014. According to the International Commission on Radiological Protection publication, we have calculated the cumulative organ dose tissue-weighting factors by using CT-EXPO software(®). We have observed a mean cumulative dose of about 27 mSv (range from 3 to 297 mSv). The distribution analysis is characterised by low effective dose, below 20 mSv, in the majority of the patients. However, in 29 patients, the effective dose was found to be higher than 20 mSv. Dose distribution for the various organs analysed (breasts, ovaries, testicles, heart and eye lenses) shows an intense peak for lower doses, but in some cases high doses were recorded. Even though cumulative doses may have long-term effects, which are still under debate, high doses are observed in this specific group of young patients.


Asunto(s)
Tomografía Computarizada Multidetector , Dosis de Radiación , Heridas y Lesiones/diagnóstico por imagen , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven
5.
Radiat Environ Biophys ; 53(2): 311-20, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24671362

RESUMEN

This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogeneous batch of glass and were stored in similar setting; for group B (formed by eight participants), samples came from different smart phones and stored in different settings of light and temperature. The calibration curves determined by the participants of group A had a small error and a critical level in the 0.37-0.40-Gy dose range, whereas the curves determined by the participants of group B were more scattered and led to a critical level in the 1.3-3.2-Gy dose range for six participants out of eight. Group A were able to assess the dose within 20 % for the lowest doses (<1.5 Gy) and within 5 % for the highest doses. For group B, only the highest blind dose could be evaluated in a reliable way because of the high critical values involved. The results from group A are encouraging, whereas the results from group B suggest that the influence of environmental conditions and the intervariability of samples coming from different smart phones need to be further investigated. An alongside conclusion is that the protocol was easily transferred to participants making a network of laboratories in case of a mass casualty event potentially feasible.


Asunto(s)
Teléfono Celular , Espectroscopía de Resonancia por Spin del Electrón/métodos , Vidrio , Radiometría/métodos , Calibración , Humanos , Estadística como Asunto
6.
Med Phys ; 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38772134

RESUMEN

BACKGROUND: The extremely fast delivery of doses with ultra high dose rate (UHDR) beams necessitates the investigation of novel approaches for real-time dosimetry and beam monitoring. This aspect is fundamental in the perspective of the clinical application of FLASH radiotherapy (FLASH-RT), as conventional dosimeters tend to saturate at such extreme dose rates. PURPOSE: This study aims to experimentally characterize newly developed silicon carbide (SiC) detectors of various active volumes at UHDRs and systematically assesses their response to establish their suitability for dosimetry in FLASH-RT. METHODS: SiC PiN junction detectors, recently realized and provided by STLab company, with different active areas (ranging from 4.5 to 10 mm2) and thicknesses (10-20 µm), were irradiated using 9 MeV UHDR pulsed electron beams accelerated by the ElectronFLASH linac at the Centro Pisano for FLASH Radiotherapy (CPFR). The linearity of the SiC response as a function of the delivered dose per pulse (DPP), which in turn corresponds to a specific instantaneous dose rate, was studied under various experimental conditions by measuring the produced charge within the SiC active layer with an electrometer. Due to the extremely high peak currents, an external customized electronic RC circuit was built and used in conjunction with the electrometer to avoid saturation. RESULTS: The study revealed a linear response for the different SiC detectors employed up to 21 Gy/pulse for SiC detectors with 4.5 mm2/10 µm active area and thickness. These values correspond to a maximum instantaneous dose rate of 5.5 MGy/s and are indicative of the maximum achievable monitored DPP and instantaneous dose rate of the linac used during the measurements. CONCLUSIONS: The results clearly demonstrate that the developed devices exhibit a dose-rate independent response even under extreme instantaneous dose rates and dose per pulse values. A systematic study of the SiC response was also performed as a function of the applied voltage bias, demonstrating the reliability of these dosimeters with UHDR also without any applied voltage. This demonstrates the great potential of SiC detectors for accurate dosimetry in the context of FLASH-RT.

7.
ACS Appl Nano Mater ; 6(18): 17206-17217, 2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37772264

RESUMEN

This study focuses on the synthesis and characterization of gadolinium-doped carbon nanodots (CDs-Gd) and their potential applications in multimodal imaging and precision cancer therapy. CDs-Gd were synthesized through a solvothermal decomposition method combining citric acid, GdCl3, and urea. The incorporation of Gd3+ ions within the carbonaceous structure resulted in stable CDs-Gd with a peculiar architecture that retained optical and paramagnetic properties. Combined characterization techniques confirmed the presence of pH-sensitive COOH functions on the CDs-Gd surface along with the unique lattice structure induced by Gd3+ doping. The optical properties of CDs-Gd exhibited a tunable emission spectrum displaying blue-green emission with pH-dependent behavior. Additionally, CDs-Gd exhibited contrast-enhancing properties in T1-weighted magnetic resonance imaging (MRI) experiments. MRI acquisitions at different Gd3+ concentrations and pH values demonstrated the potential of CDs-Gd as contrast agents for monitoring pH changes in an aqueous environment. We found that the relaxivity of CDs-Gd at pH 5.5 (tumor, 11.3 mM-1 s-1) is roughly 3-fold higher than that observed at pH 7.4 (physiological, 5.0 mM-1 s-1) and outperformed clinical standards such as γ-butyrol (3.3 mM-1 s-1). Monitoring pH changes in tumor microenvironment (TME) is crucial for evaluating the effectiveness of anticancer treatments and understanding tumor progression. Furthermore, CDs-Gd demonstrated concentration-dependent photothermal conversion ability in the near-infrared (NIR) region, allowing for efficient heat generation under laser irradiation. This indicates the potential application of CDs-Gd in image-guided photothermal therapy (IG-PTT) for cancer treatment. The in vitro studies on MCF-7 (breast cancer) and 16-HBE (healthy bronchial epithelium) cell lines demonstrated that CDs-Gd exhibited high biocompatibility (cell viability >80%). However, upon NIR activation, they showed potent anticancer effects by inhibiting tumor cell proliferation and inducing apoptosis selectively in cancer cells. In conclusion, the synthesized CDs-Gd nanoparticles possess unique optical, photothermal, and MRI contrast properties, making them promising candidates for multimodal imaging-guided precision cancer therapy applications.

8.
Radiat Prot Dosimetry ; 199(14): 1591-1599, 2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37721086

RESUMEN

This work presents the computational analysis of the sensitivity improvements that could be achieved in lithium formate monohydrate (LFM) electron paramagnetic resonance (EPR) dosemeters exposed to neutron beams. Monte Carlo (MC) simulations were performed on LFM pellets exposed to neutron beams with different energy spectra at various depths inside a water phantom. Various computations were carried out by considering different enrichments of 6Li inside the LFM matrix as well as addition of different amounts of gadolinium oxide inside the pellet blend. The energy released per unit mass was calculated with the aim of predicting the increase in dose achievable by the addition of sensitizers inside the pellets. As expected, a larger amount of 6Li induces an increase of energy released because of the charged secondary particles (i.e. 3H ions and α-particles) produced after neutron capture. For small depths in water phantom and low-energy neutron spectra the dose increase due to 6Li enrichment is high (more than three orders of magnitude with respect to the case of with 7Li). In case of epithermal neutron beams the energy released in 6Li-enriched LFM compound is smaller but larger than in the case of fast neutron beams. On the other hand, the computational analysis evidenced that gadolinium is less effective than 6Li in improving neutron sensitivity of the LFM pellets. Discussion based on the features of MC transport code is provided. This result suggests that 6Li enrichment of LFM dosemeters would be more effective for neutron sensitivity improvement and these EPR dosemeters could be tested for dosimetric applications in Neutron Capture Therapy.


Asunto(s)
Neutrones Rápidos , Neutrones , Espectroscopía de Resonancia por Spin del Electrón , Agua
9.
Front Neurosci ; 17: 1091955, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36824218

RESUMEN

Aims: During pregnancy, fetal cells can migrate to the mother via blood circulation. A percentage of these cells survive in maternal tissues for decades generating a population of fetal microchimeric cells (fMCs), whose biological role is unclear. The aim of this study was to investigate the association between the sex of offspring, an indirect marker of fMCs, and magnetic resonance imaging (MRI) features in women with multiple sclerosis (MS). Methods: We recruited 26 nulliparous MS patients (NPp), 20 patients with at least one male son (XYp), and 8 patients with only daughters (XXp). Each patient underwent brain MR scan to acquire 3D-T2w FLAIR FatSat and 3D-T1w FSPGR/TFE. Lesion Segmentation Tool (LST) and FreeSurfer were used to obtain quantitative data from MRI. Additional data were collected using medical records. Multiple regression models were applied to evaluate the association between sex of offspring and MS data. Results: Comparing NPp and XXp, we found that NPp had larger 4th ventricle volume (2.02 ± 0.59 vs. 1.70 ± 0.41; p = 0.022), smaller left entorhinal volume (0.55 ± 0.17 vs. 0.68 ± 0.25; p = 0.028), and lower thickness in the following cortical areas: left paracentral (2.34 ± 0.16 vs. 2.39 ± 0.17; p = 0.043), left precuneus (2.27 ± 0.11 vs. 2.34 ± 0.16; p = 0.046), right lateral occipital (2.14 ± 0.11 vs. 2.25 ± 0.08; p = 0.006). NPp also had lower thickness in left paracentral cortex (2.34 ± 0.16 vs. 2.46 ± 0.17; p = 0.004), left precalcarine cortex (1.64 ± 0.14 vs. 1.72 ± 0.12; p = 0.041), and right paracentral cortex (2.34 ± 0.17 vs. 2.42 ± 0.14; p = 0.015) when compared to XYp. Comparing XYp and XXp, we found that XYp had higher thickness in left cuneus (1.80 ± 0.14 vs. 1.93 ± 0.10; p = 0.042) and left pericalcarine areas (1.59 ± 0.19 vs. 1.72 ± 0.12; p = 0.032) and lower thickness in right lateral occipital cortex (2.25 ± 0.08 vs. 2.18 ± 0.13; p = 0.027). Discussion: Our findings suggested an association between the sex of offspring and brain atrophy. Considering the sex of offspring as an indirect marker of fMCs, we speculated that fMCs could accumulate in different brain areas modulating MS neuropathological processes.

10.
Eur Radiol Exp ; 7(1): 18, 2023 04 10.
Artículo en Inglés | MEDLINE | ID: mdl-37032383

RESUMEN

BACKGROUND: The role of computed tomography (CT) in the diagnosis and characterization of coronavirus disease 2019 (COVID-19) pneumonia has been widely recognized. We evaluated the performance of a software for quantitative analysis of chest CT, the LungQuant system, by comparing its results with independent visual evaluations by a group of 14 clinical experts. The aim of this work is to evaluate the ability of the automated tool to extract quantitative information from lung CT, relevant for the design of a diagnosis support model. METHODS: LungQuant segments both the lungs and lesions associated with COVID-19 pneumonia (ground-glass opacities and consolidations) and computes derived quantities corresponding to qualitative characteristics used to clinically assess COVID-19 lesions. The comparison was carried out on 120 publicly available CT scans of patients affected by COVID-19 pneumonia. Scans were scored for four qualitative metrics: percentage of lung involvement, type of lesion, and two disease distribution scores. We evaluated the agreement between the LungQuant output and the visual assessments through receiver operating characteristics area under the curve (AUC) analysis and by fitting a nonlinear regression model. RESULTS: Despite the rather large heterogeneity in the qualitative labels assigned by the clinical experts for each metric, we found good agreement on the metrics compared to the LungQuant output. The AUC values obtained for the four qualitative metrics were 0.98, 0.85, 0.90, and 0.81. CONCLUSIONS: Visual clinical evaluation could be complemented and supported by computer-aided quantification, whose values match the average evaluation of several independent clinical experts. KEY POINTS: We conducted a multicenter evaluation of the deep learning-based LungQuant automated software. We translated qualitative assessments into quantifiable metrics to characterize coronavirus disease 2019 (COVID-19) pneumonia lesions. Comparing the software output to the clinical evaluations, results were satisfactory despite heterogeneity of the clinical evaluations. An automatic quantification tool may contribute to improve the clinical workflow of COVID-19 pneumonia.


Asunto(s)
COVID-19 , Aprendizaje Profundo , Neumonía , Humanos , SARS-CoV-2 , Pulmón/diagnóstico por imagen , Programas Informáticos
11.
Front Oncol ; 12: 809279, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35280772

RESUMEN

Introduction: Metastatic cutaneous squamous cell carcinoma (cSCC) is a very rare condition. The lack of definition of an oligometastatic subgroup means that there is no consensus for its treatment, unlike the mucosal head and neck counterpart. Like the latter, the cutaneous form is able to develop bulky tumor masses. When this happens, the classic care approach is just for palliative intent due to a likely unfavorable benefit-risk balance typical of aggressive treatments. Here we proposed a novel radiotherapy (RT) technique to treat bulky metastases from cSCC in the context of an overall limited tumor burden and tried to explain its clinical outcome by the currently available mathematical radiobiological and ad hoc developed models. Methods: We treated a case of facial cSCC with three metastases: two of them by classic stereotactic RT and the other by lattice RT supported by metabolic imaging (18F-FDG PET) due to its excessively large dimensions. For the latter lesion, we compared four treatment plans with different RT techniques in order to define the best approach in terms of normal tissue complication probability (NTCP) and tumor control probability (TCP). Moreover, we developed an ad hoc mathematical radiobiological model that could fit better with the characteristics of heterogeneity of this bulky metastasis for which, indeed, a segmentation of normoxic, hypoxic, and necrotic subvolumes might have been assumed. Results: We observed a clinical complete response in all three disease sites; the bulky metastasis actually regressed more rapidly than the other two treated by stereotactic RT. For the large lesion, NTCP predictions were good for all four different plans but even significantly better for the lattice RT plan. Neither the classic TCP nor the ad hoc developed radiobiological models could be totally adequate to explain the reported outcome. This finding might support a key role of the host immune system. Conclusions: PET-guided lattice RT might be safe and effective for the treatment of bulky lesions from cSCC. There might be some need for complex mathematical radiobiological models that are able to take into account any immune system's role in order to explain the possible mechanisms of the tumor response to radiation and the relevant key points to enhance it.

12.
Nutrients ; 14(22)2022 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-36432601

RESUMEN

Indicaxanthin (IX) from Opuntia Ficus Indica (OFI) has been shown to exert numerous biological effects both in vitro and in vivo, such as antioxidant, anti-inflammatory, neuro-modulatory activity in rodent models. Our goal was to investigate the eventual neuro-active role of orally assumed fruits containing high levels of IX at nutritionally-relevant amounts in healthy subjects, exploring cortical excitability and plasticity in the human motor cortex (M1). To this purpose, we applied paired-pulse transcranial magnetic stimulation and anodal transcranial direct current stimulation (a-tDCS) in basal conditions and followed the consumption of yellow cactus pear fruits containing IX or white cactus pear fruits devoid of IX (placebo). Furthermore, resting state-functional MRI (rs-fMRI) preliminary acquisitions were performed before and after consumption of the same number of yellow fruits. Our data revealed that the consumption of IX-containing fruits could specifically activate intracortical excitatory circuits, differently from the placebo-controlled group. Furthermore, we found that following the ingestion of IX-containing fruits, elevated network activity of glutamatergic intracortical circuits can homeostatically be restored to baseline levels following a-tDCS stimulation. No significant differences were observed through rs-fMRI acquisitions. These outcomes suggest that IX from OFI increases intracortical excitability of M1 and leads to homeostatic cortical plasticity responses.


Asunto(s)
Excitabilidad Cortical , Corteza Motora , Opuntia , Estimulación Transcraneal de Corriente Directa , Humanos , Potenciales Evocados Motores/fisiología , Frutas , Corteza Motora/fisiología , Plasticidad Neuronal/fisiología
13.
Gels ; 7(2)2021 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-34205640

RESUMEN

Radiation-sensitive gels are among the most recent and promising developments for radiation therapy (RT) dosimetry. RT dosimetry has the twofold goal of ensuring the quality of the treatment and the radiation protection of the patient. Benchmark dosimetry for acceptance testing and commissioning of RT systems is still based on ionization chambers. However, even the smallest chambers cannot resolve the steep dose gradients of up to 30-50% per mm generated with the most advanced techniques. While a multitude of systems based, e.g., on luminescence, silicon diodes and radiochromic materials have been developed, they do not allow the truly continuous 3D dose measurements offered by radiation-sensitive gels. The gels are tissue equivalent, so they also serve as phantoms, and their response is largely independent of radiation quality and dose rate. Some of them are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gels). Other formulations consist of monomers dispersed in a gelatinous medium (Polyacrylamide gels) and rely on radiation-induced polymerization, which creates a stable polymer structure. In both gel types, irradiation causes changes in proton relaxation rates that are proportional to locally absorbed dose and can be imaged using magnetic resonance imaging (MRI). Changes in color and/or opacification of the gels also occur upon irradiation, allowing the use of optical tomography techniques. In this work, we review both Fricke and polyacrylamide gels with emphasis on their chemical and physical properties and on their applications for radiation dosimetry.

14.
Front Hum Neurosci ; 15: 675433, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34349631

RESUMEN

Diffusion-weighted magnetic resonance imaging (dMRI) measurements and models provide information about brain connectivity and are sensitive to the physical properties of tissue microstructure. Diffusional Kurtosis Imaging (DKI) quantifies the degree of non-Gaussian diffusion in biological tissue from dMRI. These estimates are of interest because they were shown to be more sensitive to microstructural alterations in health and diseases than measures based on the total anisotropy of diffusion which are highly confounded by tissue dispersion and fiber crossings. In this work, we implemented DKI in the Diffusion in Python (DIPY) project-a large collaborative open-source project which aims to provide well-tested, well-documented and comprehensive implementation of different dMRI techniques. We demonstrate the functionality of our methods in numerical simulations with known ground truth parameters and in openly available datasets. A particular strength of our DKI implementations is that it pursues several extensions of the model that connect it explicitly with microstructural models and the reconstruction of 3D white matter fiber bundles (tractography). For instance, our implementations include DKI-based microstructural models that allow the estimation of biophysical parameters, such as axonal water fraction. Moreover, we illustrate how DKI provides more general characterization of non-Gaussian diffusion compatible with complex white matter fiber architectures and gray matter, and we include a novel mean kurtosis index that is invariant to the confounding effects due to tissue dispersion. In summary, DKI in DIPY provides a well-tested, well-documented and comprehensive reference implementation for DKI. It provides a platform for wider use of DKI in research on brain disorders and in cognitive neuroscience.

15.
Brain Sci ; 11(1)2021 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-33406708

RESUMEN

BACKGROUND: High-quality intraoperative imaging is needed for optimal monitoring of patients undergoing transcranial MR-guided Focused Ultrasound (tcMRgFUS) thalamotomy. In this paper, we compare the intraoperative imaging obtained with dedicated FUS-Head coil and standard body radiofrequency coil in tcMRgFUS thalamotomy using 1.5-T MR scanner. METHODS: This prospective study included adult patients undergoing tcMRgFUS for treatment of essential tremor. Intraoperative T2-weighted FRFSE sequences were acquired after the last high-energy sonication using a dedicated two-channel FUS-Head (2ch-FUS) coil and body radiofrequency (body-RF) coil. Postoperative follow-ups were performed at 48 h using an eight-channel phased-array (8ch-HEAD) coil. Two readers independently assessed the signal-to-noise ratio (SNR) and evaluated the presence of concentric lesional zones (zone I, II and III). Intraindividual differences in SNR and lesional findings were compared using the Wilcoxon signed rank sum test and McNemar test. RESULTS: Eight patients underwent tcMRgFUS thalamotomy. Intraoperative T2-weighted FRFSE images acquired using the 2ch-FUS coil demonstrated significantly higher SNR (R1 median SNR: 10.54; R2: 9.52) compared to the body-RF coil (R1: 2.96, p < 0.001; R2: 2.99, p < 0.001). The SNR was lower compared to the 48-h follow-up (p < 0.001 for both readers). Intraoperative zone I and zone II were more commonly visualized using the 2ch-FUS coil (R1, p = 0.031 and p = 0.008, R2, p = 0.016, p = 0.008), without significant differences with 48-h follow-up (p ≥ 0.063). The inter-reader agreement was almost perfect for both SNR (ICC: 0.85) and lesional findings (k: 0.82-0.91). CONCLUSIONS: In the study population, the dedicated 2ch-FUS coil significantly improved the SNR and visualization of lesional zones on intraoperative imaging during tcMRgFUS performed with a 1.5-T MR scanner.

16.
Brain Sci ; 11(6)2021 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-34207681

RESUMEN

Parkinson's disease (PD) is a progressive neurodegenerative disorder, characterized by motor and non-motor symptoms due to the degeneration of the pars compacta of the substantia nigra (SNc) with dopaminergic denervation of the striatum. Although the diagnosis of PD is principally based on a clinical assessment, great efforts have been expended over the past two decades to evaluate reliable biomarkers for PD. Among these biomarkers, magnetic resonance imaging (MRI)-based biomarkers may play a key role. Conventional MRI sequences are considered by many in the field to have low sensitivity, while advanced pulse sequences and ultra-high-field MRI techniques have brought many advantages, particularly regarding the study of brainstem and subcortical structures. Nowadays, nigrosome imaging, neuromelanine-sensitive sequences, iron-sensitive sequences, and advanced diffusion weighted imaging techniques afford new insights to the non-invasive study of the SNc. The use of these imaging methods, alone or in combination, may also help to discriminate PD patients from control patients, in addition to discriminating atypical parkinsonian syndromes (PS). A total of 92 articles were identified from an extensive review of the literature on PubMed in order to ascertain the-state-of-the-art of MRI techniques, as applied to the study of SNc in PD patients, as well as their potential future applications as imaging biomarkers of disease. Whilst none of these MRI-imaging biomarkers could be successfully validated for routine clinical practice, in achieving high levels of accuracy and reproducibility in the diagnosis of PD, a multimodal MRI-PD protocol may assist neuroradiologists and clinicians in the early and differential diagnosis of a wide spectrum of neurodegenerative disorders.

17.
Front Bioeng Biotechnol ; 9: 613616, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34026738

RESUMEN

It is established that human movements in the vicinity of a permanent static magnetic field, such as those in magnetic resonance imaging (MRI) scanners induce electric fields in the human body; this raises potential severe risks of health to radiographers and cleaners exposed routinely to these fields in MRI rooms. The relevant directives and parameters, however, are based on theoretical models, and accurate studies on the simulation of the effects based on human movement data obtained in real conditions are still lacking. Two radiographers and one cleaner, familiar with MRI room activities and these directives, were gait analyzed during the execution of routine job motor tasks at different velocities. Full body motion was recorded in a gait laboratory arranged to reproduce the workspace of a room with an MRI full-body scanner. Body segments were tracked with clusters of at least three markers, from which position and velocity of the centroids were calculated. These were used as input in an established computer physical model able to map the stray field in an MRI room. The spatial peak values of the calculated electric field induced by motion of the head and of the entire body during these tasks, for both the health and sensory effects, were found smaller than the thresholds recommended by the European directives, for both 1.5 T and 3.0 T MRI. These tasks therefore seem to guarantee the safety of MRI room operators according to current professional good practice for exposure risks. Physical modeling and experimental measures of human motion can also support occupational medicine.

18.
Sci Rep ; 11(1): 2524, 2021 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-33510338

RESUMEN

The prevalence and impact of imaging findings detected during screening procedures in patients undergoing transcranial MR-guided Focused Ultrasound (tcMRgFUS) thalamotomy for functional neurological disorders has not been assessed yet. This study included 90 patients who fully completed clinical and neuroradiological screenings for tcMRgFUS in a single-center. The presence and location of preoperative imaging findings that could impact the treatment were recorded and classified in three different groups according to their relevance for the eligibility and treatment planning. Furthermore, tcMRgFUS treatments were reviewed to evaluate the number of transducer elements turned off after marking as no pass regions the depicted imaging finding. A total of 146 preoperative imaging findings in 79 (87.8%) patients were detected in the screening population, with a significant correlation with patients' age (rho = 483, p < 0.001). With regard of the group classification, 119 (81.5%), 26 (17.8%) were classified as group 1 or 2, respectively. One patient had group 3 finding and was considered ineligible. No complications related to the preoperative imaging findings occurred in treated patients. Preoperative neuroradiological findings are frequent in candidates to tcMRgFUS and their identification may require the placement of additional no-pass regions to prevent harmful non-targeted heating.


Asunto(s)
Imagen por Resonancia Magnética , Neuroimagen , Cuidados Preoperatorios , Cirugía Asistida por Computador , Tálamo/diagnóstico por imagen , Tálamo/cirugía , Ultrasonografía Intervencional , Adulto , Anciano , Anciano de 80 o más Años , Toma de Decisiones Clínicas , Manejo de la Enfermedad , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Tamizaje Masivo/métodos , Persona de Mediana Edad , Neuroimagen/métodos , Cuidados Preoperatorios/métodos , Cirugía Asistida por Computador/métodos , Tálamo/patología , Tomografía Computarizada por Rayos X , Adulto Joven
19.
Oper Neurosurg (Hagerstown) ; 18(6): 577-582, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-31598711

RESUMEN

INTRODUCTION: In recent years, transcranial Magnetic Resonance Imaging-guided Focused Ultrasound (tcMRgFUS) treatments for functional neurological disorders are giving a new thrust to the field of therapeutic brain lesioning. OBJECTIVE: To present the case of a patient affected by tremor combined with Parkinsonism who underwent a second tcMRgFUS thalamotomy because of relapsing tremor after a few months from the first tcMRgFUS treatment. METHODS: A 72-yr-old, right-handed man, came to our observation because of a disabling tremor affecting his upper limbs, refusing any invasive surgical procedure and already treated by tcMRgFUS left Vim thalamotomy. However, clinical benefit had brief duration, as a progressive recurrence of tremor on the right upper limb was observed after a few months from the first treatment. Thus, the patient underwent a new left-sided tcMRgFUS procedure 6 mo after the former treatment. RESULTS: After the second procedure, an immediate and complete relief from tremor on the right upper limb was achieved with clinical benefit that persisted up to a 6-mo follow-up. CONCLUSION: Since tcMRgFUS doesn't use ionizing radiations and it is incision-less, repeated and staged treatment procedures have always been hypothesized. Our report suggests that tcMRgFUS retreatment might actually be a feasible, safe, and effective option in selected patients in whom an optimal clinical outcome is not achieved after the first treatment session. However, future well-designed studies in large samples are needed to assess the possible risks of retreatment and the optimal timing of reintervention as well as eligibility and exclusion criteria.


Asunto(s)
Temblor Esencial , Trastornos Parkinsonianos , Anciano , Humanos , Imagen por Resonancia Magnética , Masculino , Trastornos Parkinsonianos/diagnóstico por imagen , Trastornos Parkinsonianos/cirugía , Resultado del Tratamiento , Temblor
20.
Behav Brain Res ; 390: 112668, 2020 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-32434751

RESUMEN

Gambling disorder (GD) is a psychiatric disease that has been recently classified as a behavioural addiction. So far, a very few studies have investigated the alteration of functional connectivity in GD patients, thus the concrete interplay between relevant function-dependent circuitries in such disease has not been comprehensively assessed. The aim of this research was to investigate resting-state functional connectivity in GD patients, searching for a correlation with GD symptoms severity. GD patients were assessed for gambling behaviour, impulsivity, cognitive distortions, anxiety and depression, in comparison with healthy controls (HC). Afterwards, they were assessed for resting-state functional magnetic resonance imaging; functional connectivity was assessed through a data-driven approach, by using independent component analysis. The correlation between gambling severity and the strength of specific resting-state networks was also investigated. Our results show that GD patients displayed higher emotional and behavioural impairment than HC, together with an increased resting state functional connectivity in the network including anterior cingulate cortex, the caudate nucleus and nucleus accumbens, and within the cerebellum, in comparison with the control group. Moreover, a significant correlation between behavioural parameters and the strength of the resting-state cerebellar network was found. Overall, the functional alterations in brain connectivity involving the cerebellum observed in this study underpin the emotional and behavioural impairment recorded in GD patients. This evidence suggests the employment of novel neuromodulatory therapeutic approaches involving specific and salient targets such as the cerebellum in addictive disorders.


Asunto(s)
Ansiedad/fisiopatología , Cerebelo/fisiopatología , Disfunción Cognitiva/fisiopatología , Conectoma , Depresión/fisiopatología , Regulación Emocional/fisiología , Juego de Azar/fisiopatología , Conducta Impulsiva/fisiología , Red Nerviosa/fisiopatología , Recompensa , Adulto , Ansiedad/diagnóstico por imagen , Ansiedad/etiología , Cerebelo/diagnóstico por imagen , Disfunción Cognitiva/diagnóstico por imagen , Disfunción Cognitiva/etiología , Depresión/diagnóstico por imagen , Depresión/etiología , Juego de Azar/complicaciones , Juego de Azar/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Red Nerviosa/diagnóstico por imagen , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA