Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Heart Vessels ; 34(5): 801-808, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30456724

RESUMEN

Ultra-high-density mapping allows very accurate characterization of circuits/mechanisms in atrial tachycardia (AT). Whether these advantages will translate into a better procedural or long-term clinical outcome is unknown. Sixty consecutive AT ablation procedures using ultra-high-density mapping (Rhythmia™, group 1) were retrospectively compared to 60 consecutive procedures using standard high-density mapping (Carto/NavX™, group 2) (total 209 AT, 79% left AT). A higher number of maps were performed in group 1 (4.8 ± 2.5 vs 3.2 ± 1.7, p = 0.0001) with similar acquisition duration (12 ± 5 vs 13 ± 6 min per map, p = ns), although with a greater number of activation points (10,543 ± 5854 vs 689 ± 1827 per map, p < 0.0001). AT location remained undetermined in 5 AT in group 1 vs 10 (p = 0.1). Mechanism remained undetermined in 5 AT from group 1 vs 11 (p = 0.06). Acute complete success was achieved in 77%, in both groups. At 1-year follow-up, AT recurred in 37% in group 1 vs 50% in group 2 (p = 0.046). There are less long-term recurrences after AT ablation using ultra-high-density mapping system compared to standard high-density 3D mapping, possibly because of a better comprehensive approach of AT mechanisms.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/instrumentación , Ablación por Catéter , Sistema de Conducción Cardíaco/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Anciano , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Radiografía Intervencional , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
2.
Arch Cardiovasc Dis ; 111(6-7): 456-464, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29887403

RESUMEN

Investigation and catheter ablation of cardiac arrhythmias are currently still based on optimal knowledge of arrhythmia mechanisms in relation to the cardiac anatomy involved, in order to target their crucial components. Currently, most complex arrhythmias are investigated using three-dimensional electroanatomical navigation systems, because these are felt to optimally integrate both the anatomical and electrophysiological features of a given arrhythmia in a given patient. In this article, we review the technical background of available three-dimensional electroanatomical navigation systems, and their potential use in complex ablations.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/cirugía , Imagenología Tridimensional , Potenciales de Acción , Arritmias Cardíacas/fisiopatología , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Diseño de Equipo , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Humanos , Imagenología Tridimensional/instrumentación , Valor Predictivo de las Pruebas , Resultado del Tratamiento