Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 25(4): 1339-1344, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36607137

RESUMEN

AIMS: The goal of this case series was to evaluate the feasibility, safety, and advantages of a wire-based approach for the live visualization of coronary arteries (CAs) in an electroanatomic mapping (EAM) system and to assess its diagnostic information. METHODS AND RESULTS: For this single-centre case series, we included procedures in which close proximity of a possible ablation site to any epicardial vessel was suspected. An uncoated-tip guidewire was introduced into the relevant CAs after exclusion of critical CA stenosis by coronary angiography. By connecting this wire to the EAM system using a clip and pin connection, mapping and live visualization of the wire tip is possible, as well as the assessment of the local electrograms within the respective CAs. Procedural wire insertion and intracoronary mapping was performed by EP specialists and was assisted to judge the relevance of CA disease by an interventional cardiologist. A total of nine procedures in nine patients were included in this case series, four ventricular tachycardia ablation procedures and five procedures for the ablation of premature ventricular contractions. The left CAs were mapped in eight cases and the right CA was mapped in one case. In two cases, epicardial mapping was combined with visualization of the right or left CAs. There were no complications attributed to coronary wiring and mapping in this case. CONCLUSION: We demonstrated the feasibility and safety of CA visualization and integration in an EAM. The live visualization of the CAs added valuable information without the need for preprocedural planning or the purchase of separate software. Electroanatomic visualization was achieved intraprocedurally in a safe and straightforward manner, adding critical diagnostic information without excessive costs or risks.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Estudios de Factibilidad , Corazón , Mapeo Epicárdico , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Taquicardia Ventricular/diagnóstico , Resultado del Tratamiento
2.
Pacing Clin Electrophysiol ; 46(1): 11-19, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36356298

RESUMEN

BACKGROUND: Catheter ablation has been evolved to a cornerstone in the therapy of atrial fibrillation (AF); however, atrial tachycardias (AT) after AF ablation are still an important issue. Besides the electrical recurrence of atrial tachyarrhythmia after ablation, left atrial (LA) remodeling has received attention as a consequence of AF. OBJECTIVE: The aim of this study is to evaluate predictors for AT recurrence and LA remodeling in patients with repeat AF ablation procedures. METHODS AND RESULTS: One hundred thirteen patients who underwent repeat AF ablation with 3D electro-anatomical mapping system were evaluated. Mean age was 63.1 ± 9.3 years, and 2.3 ± 0.5 ablation procedures were performed during a time period of 22 [IQR 7;48] months. Reverse structural LA remodeling (LA volume decreased more than 15%) was observed in 25 (22.1%) patients. LA volume index (LAVI) during first procedure was the only predictor for positive reverse structural LA remodeling (hazard ratio (HR): 1.03, 95% CI: 1.00-1.07, p = .036) in multivariate analysis. Fifty-nine (52.2%) patients experienced only AF and 54 (47.8%) patients AT after first procedure. Female gender (HR: 5.21, 95% CI: 1.66-18.08, p = .006), LAVI (HR: 1.06, 95% CI: 1.02-1.11, p = .008) and LA scar percentage (HR: 1.08, 95% CI: 1.02-1.17, p = .019) were independent significant predictors for AT recurrence in multivariate analysis. CONCLUSIONS: Reverse structural LA remodeling occurred in a quarter of patients with repeat ablation procedures for AF. Only larger LAVI during first procedure predicted reverse structural LA remodeling. Half of the patients experienced AT between first and last ablation procedure. Female gender, larger LAVI and larger scar area were significant predictors for AT after catheter ablation for AF.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Humanos , Femenino , Persona de Mediana Edad , Anciano , Cicatriz , Atrios Cardíacos/cirugía , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
3.
Pacing Clin Electrophysiol ; 46(2): 161-168, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36588339

RESUMEN

BACKGROUND: Catheter ablation is an effective treatment for atrial fibrillation (AF,) but arrhythmia recurrence occurs in a relevant number of patients. Mechanisms of late occurring arrhythmias after ablation procedures are not fully understood. We analyzed electrophysiological mechanisms of early and late arrhythmia recurrences in patients who underwent radiofrequency-based catheter ablation of AF. METHODS AND RESULTS: Consecutive patients who underwent repeat ablation procedures after initial pulmonary vein isolation (PVI) for symptomatic arrhythmia recurrence were analyzed. A total of 110 consecutive patients who underwent catheter ablation for paroxysmal (79%) or persistent AF (21%) were included. Forty-seven patients suffered from early arrhythmia recurrence (group #1: 3-24 months), 29 patients from mid-term arrhythmia recurrences (group #2: 2-5 years), and 34 patients from late arrhythmia recurrences (group #3: > 5 years). Electrical PV reconnection was found in 98% in group #1, 72% in group #2 and 56% in group #3 (p < .001). Mode of arrhythmia recurrence was organized tachycardia in 25%, 28%, and 65% of patients in groups #1, #2, and #3 (p = .001), respectively. Patients with late arrhythmia recurrence had more pronounced left atrial low voltage as compared to patients with early arrhythmia recurrence based on two published scoring system. CONCLUSION: Electrical PV reconnection was found in the majority of patients with early AF recurrence after PVI. In patients with late arrhythmia recurrences this mechanism may play an inferior role, with many patients presenting without PV reconnection, but with LA structural alterations. Thus, early and late occurring arrhythmia recurrence after catheter ablation may be the same symptom of different diseases.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Recurrencia , Atrios Cardíacos , Resultado del Tratamiento , Ablación por Catéter/métodos
4.
J Cardiovasc Electrophysiol ; 33(6): 1096-1103, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35304790

RESUMEN

BACKGROUND: Cryoballoon (CB)-based pulmonary vein isolation (PVI) has proven to be as effective as radiofrequency-based ablation. Different ablation protocols took the individual time-to-isolation (TTI) into account aiming at shorter but equally or even more effective freeze cycles. The current study sought to assess the impact of the TTI on PVI durability in patients undergoing a repeat procedure for recurrence of atrial tachyarrhythmia (ATA). METHODS AND RESULTS: In 205 patients with ATA recurrence after previous CB-based PVI, a total of 806 pulmonary veins (PVs) were identified. A total of 126 out of 806 PVs (16%) were previously treated with a TTI-guided ablation (Protocol #1; TTI + 120 s), in 92/806 (11%) PVs TTI was only monitored (m) but fixed freeze cycles were applied (Protocol #2; mTTI) and in 588/806 (73%) a fixed freeze cycle was applied without mTTI. There was no difference in the PV-reconduction rate between the groups (p = .23). The right inferior pulmonary vein (RIPV) showed overall significantly higher reconduction rates compared to the other PVs (RIPV-left inferior PV p < .003, -left superior PV p < .001, -right superior PV p < .013). Twenty-one patients (10%) were demonstrated to have only electrical reconduction of the RIPV, while all other PVs were still electrically isolated. CONCLUSIONS: The TTI-based CB ablation protocol did not show significant differences regarding PV-reconduction rates compared to the other ablation protocols.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 33(4): 654-663, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35118743

RESUMEN

INTRODUCTION: The prevalence of obesity is increasing. However, data on the periprocedural complication rate of catheter ablation for arrhythmia in patients stratified by body mass index (BMI) are scarce. METHODS: This study included 1000 consecutive patients (age 62.0 ± 14.4 years) undergoing catheter ablation for cardiac arrhythmia. The primary study endpoint was any periprocedural major complication (cardiac tamponade, pseudoaneurysm, arteriovenous fistula, transient ischemic attack, stroke, valve damage, myocardial infarction, or death). RESULTS: The mean BMI was 27.6 ± 5.1 kg/m2 and the majority of patients were overweight (BMI 25.0-29.9 kg/m2 , 43.4%). A BMI of 30.0-34.9 kg/m2 (Class I obesity) was present in 177 (17.7%) of patients, a BMI of 35.0-39.9 kg/m2 (Class II obesity) in 67 (6.7%), and a BMI ≥ 40 kg/m2 (Class III obesity) in 16 (1.6%). There were 31 major complications (3.1%) and one fatality (0.1%) due to terminal heart failure in a patient undergoing palliative ventricular tachycardia ablation. There was no significant impact of the BMI on the rate of major complications (p = .495). Compared to normal weight patients, odds ratios for complications in overweight patients, as well as Class I, II, and III obesity were 1.1 (95% confidence interval (CI): 0.8, 1.7), 1.3 (CI: 0.6, 2.6), 1.4 (CI: 0.5, 4.1), and 1.6 (CI: 0.4, 6.3), respectively. Radiation exposure and procedure duration were significantly increased in obese patients (p < .001 and p = .001, respectively). CONCLUSION: In this study, obesity did not have a significant impact on the incidence of periprocedural complications after CA for cardiac arrhythmia.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Índice de Masa Corporal , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Persona de Mediana Edad , Obesidad/complicaciones , Obesidad/diagnóstico , Obesidad/epidemiología , Sobrepeso/complicaciones , Factores de Riesgo
6.
Pacing Clin Electrophysiol ; 45(9): 1024-1031, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35822917

RESUMEN

BACKGROUND: Perimitral flutter and atrial fibrillation may occur in patients with prior surgical mitral valve (MV) repair or replacement and can be challenging for percutaneous catheter ablation. This study sought to determine the feasibility, acute success and durability of catheter ablation of atrial fibrillation or atrial tachycardia by way of a mitral isthmus line (MIL) or an anterior line (AL). METHODS: A total of 81 patients (49 males, mean age 62±11 years) with prior MV replacement (n = 30) or reconstruction (n = 51) underwent creation of a MIL (34) and/or an AL (72). RESULTS: Acute bidirectional block of the MIL was successfully achieved in 24/34 cases and of the AL in 64/72 patients. Patients of the control group without prior MV surgery were matched 1:1 with the valve group. In the AL control subgroup, acute bidirectional block was achieved in 65/72 patients. Acute blockage in the MIL control subgroup could be achieved in 31/34 patients. The MIL valve subgroup showed the worst results in terms of durability, whereas a similar trend emerged in the control group and the AL valve subgroup (probability of failure in MIL valve subgroup 2.224 vs. MIL control subgroup 0.605 [Hazard Ratio (HR) = 0.27, 95% confidence interval (CI), 0.11-0.65), P = .004]; probability of failure in AL valve subgroup 0.844 vs. AL control subgroup 1.03 [HR = 1.22 (95% CI, 0.66-2.26), P = .523]). CONCLUSIONS: Percutaneous creation of MIL and AL is feasible and safe in patients with prior MV replacement/repair and associated with moderate acute and long-term success rates to achieve bidirectional block.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Anciano , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/cirugía , Resultado del Tratamiento
7.
J Thromb Thrombolysis ; 51(1): 74-80, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32447744

RESUMEN

Stroke after catheter ablation (CA) of atrial fibrillation (AF) is a potential complication with long term consequences. Aim of this study was to determine incidence and potential predictors of stroke and left atrial appendage (LAA) thrombi after AF ablation with cryo-energy. Two hundred nine consecutive patients with symptomatic drug refractory AF (65% male; 61 ± 11 yo, 69% paroxysmal AF, mean CHA2DS2-VASc score 2 ± 1.4) were enrolled between October 2012 until December 2015. Long term follow-up was performed with outpatient clinic visits at 6-month intervals. Incidence of stroke after CA was 1.4% (3/209 pts) at long term follow-up. Two out of 3 pts experienced stroke during the first 3 month after CA and one after 36 months. At long term follow-up LAA thrombi were found in two patients (1%) that were on therapeutic oral anticoagulation. Recurrence of AF was found in 4 out of 5 pts with stroke or LAA thrombi. Patients with stroke or LAA thrombi did not differed from those without in term of age, gender, CV risk factors, LA size and AF type. They differed only for EHRA score (2.4 vs 1.3, p = 0.01) before CA. At multivariate analysis after correction for age, gender, LA size, LVEF and AF type, only EHRA score (ß 1.92, 95% C.I. 1.3-35 p = 0.02), was an independent predictor of stroke/LAA thrombi. Incidence of stroke after cryoablation is low, with a relative higher prevalence during the first 3 months after CA. Prospective, multicenter long-term registries are needed for a better stroke risk stratification.


Asunto(s)
Apéndice Atrial/patología , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Accidente Cerebrovascular/etiología , Trombosis/etiología , Anciano , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Pronóstico , Accidente Cerebrovascular/diagnóstico , Trombosis/diagnóstico
8.
Int Heart J ; 62(1): 65-71, 2021 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-33455982

RESUMEN

Left atrial (LA) fibrosis is associated with a poor outcome after atrial fibrillation (AF) ablation. This study examined the extent of low-voltage areas in patients with recurrence of atrial tachyarrhythmia (ATA) after CB-based pulmonary vein isolation (PVI).Sixty patients (mean age 67 ± 10 years, n = 32 female; n = 34 paroxysmal AF) who received radiofrequency redo-procedure due to recurrence of ATA within 6 months after CB-based PVI were included. A point-by point 3D-map was performed, and low-voltage sites were delineated based on bipolar voltage < 0.5 mV. The extent of fibrosis was categorized as stage A (0-10% of the LA wall), stage B (10-30%), stage C (30-50%), and stage D (> 50%).The median area of LA low-voltage sites was 28.9 (9; 50.3) cm2, corresponding to 17.4 (6; 30.6) % of the LA wall surface. 17/60 (28.3%) patients were categorized as fibrosis stage A, 21/60 (35%) as stage B, 18/60 (30%) as stage C, and 4/60 (6.7%) as stage D. Patient age and LA diameter were associated with more pronounced LA fibrosis; the extent of LA fibrosis was significantly higher in patients with LA tachycardia (LAT) during redo-procedures (P < 0.01), and ablation of linear lesions was more often performed (P < 0.01).In patients after CB2-based PVI, expanded LA tissue fibrosis was associated with the occurrence of LAT and more extensive LA ablation during redo-procedures.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Fibrosis/complicaciones , Atrios Cardíacos/patología , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Femenino , Fibrosis/clasificación , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Taquicardia Supraventricular/epidemiología , Taquicardia Supraventricular/etiología , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 31(5): 1068-1074, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32128924

RESUMEN

AIMS: The current study sought to assess the impact of the utilized energy source during index ablation on long-term clinical outcomes after repeat ablation of atrial fibrillation (AF). Index ablation procedures were either performed using radiofrequency current (RFC) (RFC group) or cryoballoon (CB) ablation (CB group). Repeat ablation was performed by the use of RFC. METHODS: A total of 195 patients (138 RFC group; 57 CB group) with paroxysmal AF were included. All patients had a recurrence of AF following the index ablation procedure. Freedom from AF was estimated with the Kaplan-Meier method. RESULTS: After a 3 years follow-up, the estimated arrhythmia-free survival did not differ between the two groups (RFC group 48% vs CB group 47%, P = .78). During index ablation, procedure times were significantly shorter in the CB group (95 [80, 140] vs 140 [115, 164] minutes, P ≤ .001), whereas fluoroscopy times (16 [11; 22] vs 19 [14; 25] minutes, P = .003), the dose area product (1862 [1203; 2922] vs 3148 [1756; 5888] cGycm2 , P ≤ .001) and the amount of contrast dye (92 ± 32 vs 123 ± 33 mL, P ≤ .001) were significantly lower in the RFC group. During repeat ablation, procedure times were significantly shorter in patients being initially treated with RFC (115 [85; 145] vs 125 [105; 150] minutes, P = .007). There was a trend towards a higher pulmonary vein reconnection rate in the RFC group without meeting statistical significance (P = .074). CONCLUSIONS: In patients with repeat ablation of AF, index RFC or CB ablation are equally effective in terms of freedom from AF. Although CB ablation results in shorter index procedures times, durations of repeat ablation are significantly longer.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Supervivencia sin Enfermedad , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
10.
Europace ; 22(8): 1240-1251, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32500141

RESUMEN

AIMS: The aim of this study was to analyse tamponades following electrophysiological procedures regarding frequency and mortality in a high-volume centre and to identify independent predictors for severe tamponades. METHODS AND RESULTS: We performed a retrospective study on 34 982 consecutive patients undergoing diagnostic electrophysiological studies or catheter ablation of cardiac arrhythmias. The combined endpoint was defined as severe tamponade. Criteria for severe tamponade included surgical repair, repeat pericardiocentesis, cardiopulmonary resuscitation, intrahospital death or death during follow-up, and thrombo-embolic events or complications due to therapeutic management. Multivariate analysis was performed to identify independent predictors for severe tamponade. A total of 226 tamponades were identified. Overall frequency of tamponades was 0.6%. Procedures requiring epicardial approach had the highest rate of tamponades (9.4%). Twenty-nine patients with tamponade underwent surgery (12.8% of all tamponades and 21.4% of tamponades during epicardial procedures). Overall tamponade-related mortality was 0.03% (9 deaths). Fifty-six patients (24.8%) experienced severe tamponade. Independent risk factors for severe tamponades were endocardial ablation of ventricular tachycardia, epicardial approach, balloon device ablation, high aspiration volume during pericardiocentesis and structural heart disease. CONCLUSION: The frequency of tamponades is strongly dependent on the type of procedure performed. Overall tamponade-related mortality was low but significantly higher in patients undergoing epicardial procedures. Surgical backup should be considered for patients undergoing complex ventricular tachycardia ablation and left atrial ablation procedures.


Asunto(s)
Taponamiento Cardíaco , Ablación por Catéter , Electrofisiología Cardíaca , Taponamiento Cardíaco/diagnóstico , Taponamiento Cardíaco/cirugía , Ablación por Catéter/efectos adversos , Humanos , Pericardiocentesis/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
11.
Circ J ; 84(6): 902-910, 2020 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-32307357

RESUMEN

BACKGROUND: The second-generation cryoballoon (CB2) has demonstrated high procedural efficacy and convincing clinical success rates for pulmonary vein isolation (PVI). Nevertheless, data on the impact of different ablations protocols on durability are limited. The aim was to comparing the durability of PVI following 3 different ablation strategies in patients with recurrence of atrial fibrillation or atrial tachycardia undergoing repeat procedures.Methods and Results:In 192 patients, a total of 751 PVs were identified. All PVs were successfully isolated during index PVI. Thirty-one out of 192 (16%) patients were treated with a bonus-freeze protocol (group 1), 67/192 (35%) patients with a no bonus-freeze protocol (group 2), and 94/192 (49%) patients with a time-to-effect-guided protocol (group 3). Persistent PVI was documented in 419/751 (55.8%) PVs, and in 41/192 (21%) patients, all PVs were persistently isolated. The total rate of PV reconnection was not significantly different between the groups (P=0.134) and the comparison of individual PVs revealed no differences (P-values for RSPV: 0.424, RIPV: 0.541, LSPV: 0.788, LIPV: 0.346, LCPV: 0.865). The procedure times were significantly reduced by omitting the bonus-freeze and applying individualized application times (group 1: 123.4±31.5 min, group 2: 112.9±39.8 min, group 3: 86.67±28.4 min, P<0.001). CONCLUSIONS: Comparing 3 common ablation protocols, no differences for durable PVI were detected. Procedure times were significantly reduced by omitting the bonus-freeze cycle and by applying individualized application times.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Criocirugía/métodos , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
12.
Cardiology ; 145(10): 676-681, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32854099

RESUMEN

INTRODUCTION: Periprocedural oral anticoagulation (OAC) strategies for atrial fibrillation (AF) ablation procedures are changing rapidly. OBJECTIVE: To assess the management and course of periprocedural OAC for AF ablation procedures in experienced electrophysiology (EP) centers in Germany over the last 12 months. METHODS: The data are based on an electronic questionnaire, which was sent to 35 experienced EP centers in September 2018 and then exactly 1 year later. Participants provided information on their periprocedural OAC management, the handling with dual therapy (OAC plus single antiplatelet therapy), the availability of specific antidotes, the transseptal puncture approach, and noteworthy complications. RESULTS: Responses were received from all 35 centers and represent 10,010 AF ablation procedures annually. In 2018, the administration of vitamin K antagonist (VKA) was continued throughout the procedure at all centers (100%). In contrast, the majority of centers used minimally interrupted periprocedural non-vitamin K antagonist oral anticoagulants (NOAC) (54.3%), 13 centers (37.2%) completely interrupted NOAC, and only 3 centers (8.5%) continued NOAC throughout the procedure. At the 1-year follow-up survey, 32 centers were found to have continued their previous strategy of periprocedural OAC and 3 changed from a minimally interrupted to a continued NOAC strategy. Of note, 30 centers (85.7%) performed transseptal puncture fluoroscopically without additional cardiac imaging. In the setting of uninterrupted periprocedural OAC management, no relevant complications were noted. CONCLUSION: Our survey shows marked heterogeneous periprocedural OAC management at experienced EP centers in Germany. Whereas continuation of VKA has already been integrated into clinical practice, the majority of centers still use a minimally interrupted NOAC strategy.


Asunto(s)
Anticoagulantes , Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Administración Oral , Anticoagulantes/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Alemania , Heparina de Bajo-Peso-Molecular , Humanos , Accidente Cerebrovascular/tratamiento farmacológico , Encuestas y Cuestionarios
13.
Pacing Clin Electrophysiol ; 43(10): 1115-1125, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32794580

RESUMEN

BACKGROUND: Catheter ablation of atrial fibrillation (AF) in patients with pulmonary lobectomy or pneumectomy is challenging due to anatomical alterations. After lung resection, electrically active pulmonary vein (PV) stumps remain and need to be localized for PV isolation (PVI). The present study aims to describe clinical challenges of PVI in patients with pulmonary lobectomy or pneumectomy. METHODS: We performed a retrospective study on 19 patients with previous pulmonary lobectomy or pneumectomy undergoing catheter ablation for AF in three German hospitals. RESULTS: Nineteen patients with paroxysmal, persistent, or longstanding-persistent AF and history of pulmonary lobectomy (n = 11) or pneumectomy (n = 8) were enrolled. Catheter ablation was performed as radiofrequency (RF) ablation using 3D mapping, robotic RF ablation, or by using balloon devices. Decent anatomical changes were observed in patients with lobectomy while cardiac rotation and mediastinal shifting was dominant in patients with pneumectomy. Visualization of all PVs including PV stumps by PV angiography was possible in 10 of 19 patients (52.6%). PV spikes were observed in all identified PV remnants. In nine patients (47.4%), at least one PV remnant could not be identified and electrical isolation was not performed. During 24 months follow-up, patients with incomplete PVI had a significantly shorter arrhythmia-free survival than patients with complete PVI (76.2% [95% Confidence interval (CI) 47.2-100.0%] vs 40.0% [95% CI 5.6-74.1%], P = .043). CONCLUSION: In patients with AF and previous lobectomy or pneumectomy, identification and isolation of all PVs are challenging but crucial for ablation success. Additional imaging techniques may be necessary to achieve complete PVI.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Neumonectomía , Venas Pulmonares/cirugía , Anciano , Anticoagulantes/administración & dosificación , Fibrilación Atrial/diagnóstico por imagen , Ablación por Catéter/instrumentación , Ecocardiografía Transesofágica , Mapeo Epicárdico , Femenino , Alemania , Humanos , Masculino , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/instrumentación
14.
J Contemp Dent Pract ; 21(1): 22-27, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-32381796

RESUMEN

INTRODUCTION: This is an in vitro study to evaluate the degree of conversion (DC) of nanoceramic and microhybrid composites activated by different polymerization modes at different intervals. AIM: To determine the DC of two resin composites at different time intervals and modes of polymerization on DC. MATERIALS AND METHODS: Two commercially available composite resins-nanoceramic (Ceram X, Dentsply) and microhybrid (Spectrum TPH, Dentsply)-were used in this study. A total of 80 cylindrical samples (n = 40 each) were made by packing the composites in one increment into (5 × 2 mm) Teflon molds and cured using a light-emitting diode (LED) at an irradiance of 1,200 mW/cm2. Each group was further divided into two groups (n = 20) based on the curing modes (20 seconds, 40 seconds). These 20 samples were further subdivided (n = 10) based on the time interval (2 days, 7 days). Degree of conversion was assessed by Fourier-transform infrared spectrophotometer (FTIR) using a direct technique (attenuated total reflectance) on the top surface of the samples. Degree of conversion was measured for samples cured for 20 seconds (n = 10) and 40 seconds (n = 10) after 2 days and 7 days during which the samples were stored in an incubator at 37°C, 90% ± 10% relative humidity. The results obtained were statistically analyzed using two-way and three-way analysis of variance (ANOVA) test and p value set at (<0.005) significance level. RESULTS: Degree of conversion for the tested composites varied between 44% and 55% for Ceram X and 42% and 45% for Spectrum TPH. A significant difference was observed in DC for Ceram X samples for different polymerization modes (20 seconds and 40 seconds) as well as at 2-7 days measurement, whereas Spectrum TPH did not show any significant difference for polymerization modes. CONCLUSION: Ceram X demonstrated high DC values compared with that of Spectrum TPH with regard to two different polymerization modes. CLINICAL SIGNIFICANCE: Lesser the time required for conversion and less the residual monomer left, better is the prognosis of the restoration, and better is the patient satisfaction.


Asunto(s)
Resinas Acrílicas , Resinas Compuestas , Poliuretanos , Análisis de Varianza , Humanos , Ensayo de Materiales , Polimerizacion , Espectroscopía Infrarroja por Transformada de Fourier
15.
J Cardiovasc Electrophysiol ; 30(9): 1436-1442, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31190440

RESUMEN

AIMS: We sought to assess (1) clinical outcomes of second-generation cryoballoon (CB) ablation for persistent atrial fibrillation (AF), and (2) the association of baseline and procedural covariates with atrial arrhythmia recurrence (AAR) after ablation. METHODS: A total of 135 patients (63 ± 11 years, 96 men [71%]) with persistent AF underwent CB ablation at three experienced electrophysiology centers. Freedom from AAR was estimated with the Kaplan-Meier method. A Cox proportional-hazards model was used to estimate the effects of baseline and procedural covariates on the likelihood of AAR. RESULTS: Freedom from AAR at 6, 12, and 18 months was estimated at 91% (95% confidence interval [CI] 86%-96%), 75% (95% CI, 67%-83%), and 53% (95% CI, 43%-65%), respectively. The presence of an implantable cardiac device (Hazard ratio [HR] 3.09; 95% CI, 1.37-7.00; P = .007), a left atrial (LA) diameter > 50 mm (HR 1.69; 95% CI, 1.02-2.79; P = .043), and absence of antiarrhythmic drug (AAD) therapy before the ablation procedure (HR 3.12; 95% CI, 1.72-5.64; P < .001) were associated with AAR. A trend toward an increased risk of AAR was revealed for women (HR 1.73; 95% CI, 0.96-3.11; P = .069). CONCLUSIONS: CB ablation for persistent AF resulted in freedom from AAR about that reported for RF ablation. The presence of an implantable cardiac device, LA size, and absence of AAD therapy at baseline were associated with the risk of AAR.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Criocirugía/instrumentación , Femenino , Alemania , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
16.
J Cardiovasc Electrophysiol ; 30(8): 1207-1214, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31045293

RESUMEN

BACKGROUND: Atrial fibrillation (AF) and higher grade mitral valve regurgitation are often associated. For both, there are interventional therapeutic options such as pulmonary vein isolation (PVI) and percutaneous mitral valve repair (PMVR) using MitraClip. OBJECTIVE: This study investigated the feasibility, safety and clinical outcome of AF ablation in patients with prior PMVR. METHODS: This study included patients with symptomatic AF who underwent PVI after prior PMVR at a tertiary care center (14 consecutive patients, group I). A propensity-score matched group of 42 patients (1:3 matching, group II) without prior valve repair acted as controls. RESULTS: Acute PVI was achieved in all patients. No difference was found regarding median procedure time (group I: 125.0 [Q1: 120.0; Q3: 176.3] vs group II: 135.0 [120.0; 177.5] minutes; P = 0.87) and median fluoroscopy duration (group I: 17.2 [12.9; 25.9] vs group II: 18.6 [12.3; 25.9] minutes; P = 0.95). In group I, one patient suffered a postprocedural transient ischemic attack. No further major complications occurred (P = 0.25). No periprocedural interference with the MitraClip was noted. The Kaplan-Meier estimate 18-month overall arrhythmia-free survival after the index procedure including a 3-month blanking period was 64.8% (95% confidence interval [CI] 42.1-99.8%) for the study group and 68.3% (95% CI, 54.6-85.6%) for the control group P = 0.35). A higher percentage of left atrial tachycardias was observed in the study group (67% vs 12% of patients with any arrhythmia recurrence; P = 0.01). CONCLUSION: Catheter ablation of AF in patients with prior PMVR is feasible and safe and results in satisfying clinical outcome.


Asunto(s)
Fibrilación Atrial/cirugía , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Venas Pulmonares/cirugía , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Estudios de Casos y Controles , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Venas Pulmonares/fisiopatología , Recurrencia , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
17.
Europace ; 21(7): 1106-1115, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30887036

RESUMEN

AIMS: Inadvertent puncture of the aortic root (AR) is a well-known complication of transseptal puncture (TSP). Strategies for handling of this potentially lethal complication have not been identified yet. In this study, we present typical anatomical locations and clinical management of aortic root puncture (ARP) due to TSP. METHODS AND RESULTS: All patients with ARP were retrospectively collected from seven hospitals. Aortic root puncture was identified and classified regarding angiographical and intraoperative findings in cardiac surgery: (i) TSP from the right atrium (RA) to the non-coronary sinus (NCS), (ii) TSP from RA to the non-coronary sinutubular junction (STJ), and (iii) TSP from RA to the ascending aorta (AA). A total of 24 patients with inadvertent ARP were identified. In 19 patients, penetration of the aorta was accomplished by the inner dilator, in 5 patients by the complete sheath. Previous cardiac surgery had been performed in six patients. There were 13 RA-to-NCS punctures, 2 RA-to-STJ punctures, and 9 RA-to-AA punctures. No cardiac tamponade (CT) occurred in patients with RA-to-NCS and RA-to-STJ punctures. In 8 of 9 patients with RA-to-AA puncture, CT occurred immediately requiring urgent pericardiocentesis and surgical repair. Two patients died after surgical repair. In the 16 patients without surgical therapy, no shunt from the AR to the RA was observed 3 months after the procedure. CONCLUSION: Aortic root puncture due to mislead TSP via NCS or STJ is usually not associated with a severe clinical course while ARP into the AA via the epicardial space generally leads to CT requiring surgical repair.


Asunto(s)
Aorta Torácica/lesiones , Tabique Interatrial/cirugía , Procedimientos Quirúrgicos Cardíacos , Punciones/efectos adversos , Angiografía , Femenino , Humanos , Enfermedad Iatrogénica , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
18.
Europace ; 21(10): 1494-1501, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31327016

RESUMEN

AIMS: Arrhythmia recurrence is a common clinical problem in patients with pulmonary vein stenosis (PVS) following catheter ablation of atrial fibrillation. The study sought to analyse the management of arrhythmia recurrence in patients with PVS. METHODS AND RESULTS: Retrospective analysis was performed on 29 patients with high-degree PVS. Follow-up contained clinical visits, Holter-electrocardiogram recordings and invasive pulmonary vein (PV) angiography and electrophysiological studies. Arrhythmia recurrence was observed in 18 patients (62%) after PVS formation. Fifteen of 18 patients (83.3%) with and 1 of 11 patients (9.1%) without arrhythmia recurrence had electrical PV reconnection (P = 0.0003). In 14 of 16 patients repeat pulmonary vein isolation (PVI) was conducted (radiofrequency ablation in 12 and cryoballoon ablation in 2 cases). Repeat PVI was successful in all PVs in nine patients and incomplete in five patients (failed attempt in two patients with stent implantation, no attempt in three patients with stenotic PVs). Freedom from arrhythmia recurrence was estimated at 56.3% [95% confidence interval (CI) 36.4-72.0%] after 24 months. At the end of the follow-up, complete PVI was documented in 19 of 23 patients (82.6%) with stable sinus rhythm and in 2 of 6 patients with arrhythmia recurrence (33.3%) (P = 0.0335). The Kaplan-Meier estimate of recurrence-free survival of restenosis after interventional PVS treatment was similar in patients without and with repeat ablation [75.6% (95% CI 57.0-94.3%) and 67.0% (95% CI 43.2-90.7%) after 500 days, P = 0.77]. CONCLUSIONS: Pulmonary vein reconnection is the major driver of arrhythmia recurrence in PVS patients. Repeat PVI is feasible and does not lead to progression of PVS or restenosis if the procedure is carefully performed.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Sistema de Conducción Cardíaco/fisiopatología , Complicaciones Posoperatorias , Estenosis de Vena Pulmonar/etiología , Stents , Procedimientos Quirúrgicos Vasculares/métodos , Angiografía , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Electrocardiografía Ambulatoria , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Estenosis de Vena Pulmonar/diagnóstico , Estenosis de Vena Pulmonar/cirugía , Resultado del Tratamiento
19.
Circ J ; 83(8): 1653-1659, 2019 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-31257357

RESUMEN

BACKGROUND: Second-generation cryoballoon (CB2)-based pulmonary vein isolation (PVI) has demonstrated encouraging results in the treatment of atrial fibrillation (AF). This study sought to assess data on the safety, efficacy and clinical success of CB2-based PVI in patients with heart failure (HF) and reduced ejection fraction (HFrEF).Methods and Results:CB2-based PVI was performed in 551 consecutive patients in 3 highly experienced EP centers. Patients with HF and LVEF ≤40% were included (HFrEF group, n=50/551, 9.1%). Data were compared with propensity score-matched patients without HF and preserved left ventricular EF (LVEF) (n=50, control group). The median LVEF was HFrEF: 37% (35, 40) and control: 55% (55, 55), P<0.0001. Major periprocedural complications were registered in 4/50 (8%, HFrEF group) and 3/50 (6%, control group), P=0.695. The 12-month freedom from AF recurrence was 73.1% (95% confidence interval (CI): 61-88, HFrEF group) and 72.6% (95% CI: 61-87, control group), P=0.25. NYHA class decreased from 2.4±0.8 (baseline) to 1.7±0.8 at 12-month follow-up (P<0.0001). LVEF improved from a median of 37% (35, 40) prior to ablation to a median of 55% (40, 55), P<0.0001. CONCLUSIONS: CB2-based PVI in patients with HFrEF appeared to be safe, was associated with comparable periprocedural complications and showed promising clinical success rates equal to those for patients with preserved LVEF. NYHA class and LVEF significantly improved at 12-month follow-up.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Criocirugía/instrumentación , Insuficiencia Cardíaca/fisiopatología , Venas Pulmonares/cirugía , Función Ventricular Izquierda , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Diseño de Equipo , Femenino , Alemania , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Venas Pulmonares/fisiopatología , Recuperación de la Función , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo
20.
J Cardiovasc Electrophysiol ; 29(2): 257-263, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29216412

RESUMEN

INTRODUCTION: Ablation of persistent atrial fibrillation (AF) is a potential treatment option for symptomatic patients. We sought to evaluate the critical role of circumferential pulmonary vein isolation (CPVI) in the ablation of persistent AF. METHODS AND RESULTS: A total of 341 ablation procedures were performed in 174 consecutive patients with persistent AF. CPVI was performed in all patients, additional ablation was only performed if electrical cardioversion failed after CPVI. During a median follow-up (FU) of 89 (63; 89) months, stable sinus rhythm was documented in 42/170 (25%) patients after a single procedure and in 111/164 (68%) patients after 1.9 ± 1.1 procedures. Stable SR was achieved in 40/75 (53%) patients in whom only CPVI was performed during the index and repeat procedures and in 71/89 (79%) patients with CPVI plus additional ablation. The main predictor for ablation success was duration of persistent AF before the index procedure (P < 0.001, HR ± CI: 1.608 [1.034, 1.103]). Responders to CPVI during the initial procedure had a significantly better multiple-procedure outcome after 42 months of FU compared to CPVI nonresponders (P  =  0.0365). Conversion during the index procedure had no impact on clinical outcomes (P  =  0.0903). Persistent AF regressed to paroxysmal AF in 16% of patients. CONCLUSIONS: We demonstrate a 25% single- and 68% multiple-procedure success in patients with persistent AF, while stable SR was achieved in 53% of patients with pure CPVI during all procedures and in 79% of patients with CPVI plus additional ablation. Only duration of persistent AF before ablation had a statistically significant impact on ablation outcome.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA