Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 248
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Radiology ; 310(2): e231501, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38376399

RESUMEN

Background The independent contribution of each Liver Imaging Reporting and Data System (LI-RADS) CT or MRI ancillary feature (AF) has not been established. Purpose To evaluate the association of LI-RADS AFs with hepatocellular carcinoma (HCC) and malignancy while adjusting for LI-RADS major features through an individual participant data (IPD) meta-analysis. Materials and Methods Medline, Embase, Cochrane Central Register of Controlled Trials, and Scopus were searched from January 2014 to January 2022 for studies evaluating the diagnostic accuracy of CT and MRI for HCC using LI-RADS version 2014, 2017, or 2018. Using a one-step approach, IPD across studies were pooled. Adjusted odds ratios (ORs) and 95% CIs were derived from multivariable logistic regression models of each AF combined with major features except threshold growth (excluded because of infrequent reporting). Liver observation clustering was addressed at the study and participant levels through random intercepts. Risk of bias was assessed using a composite reference standard and Quality Assessment of Diagnostic Accuracy Studies 2. Results Twenty studies comprising 3091 observations (2456 adult participants; mean age, 59 years ± 11 [SD]; 1849 [75.3%] men) were included. In total, 89% (eight of nine) of AFs favoring malignancy were associated with malignancy and/or HCC, 80% (four of five) of AFs favoring HCC were associated with HCC, and 57% (four of seven) of AFs favoring benignity were negatively associated with HCC and/or malignancy. Nonenhancing capsule (OR = 3.50 [95% CI: 1.53, 8.01]) had the strongest association with HCC. Diffusion restriction (OR = 14.45 [95% CI: 9.82, 21.27]) and mild-moderate T2 hyperintensity (OR = 10.18 [95% CI: 7.17, 14.44]) had the strongest association with malignancy. The strongest negative associations with HCC were parallels blood pool enhancement (OR = 0.07 [95% CI: 0.01, 0.49]) and marked T2 hyperintensity (OR = 0.18 [95% CI: 0.07, 0.45]). Seventeen studies (85%) had a high risk of bias. Conclusion Most LI-RADS AFs were independently associated with HCC, malignancy, or benignity as intended when adjusting for major features. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Crivellaro in this issue.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Adulto , Masculino , Humanos , Persona de Mediana Edad , Femenino , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Cintigrafía , Imagen por Resonancia Magnética
2.
J Obstet Gynaecol Can ; 46(6): 102435, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38458270

RESUMEN

OBJECTIVES: To compare surgeon responses regarding their surgical plan before and after receiving a patient-specific three-dimensional (3D)-printed model of a patient's multifibroid uterus created from their magnetic resonance imaging. METHODS: 3D-printed models were derived from standard-of-care pelvic magnetic resonance images of patients scheduled for surgical intervention for multifibroid uterus. Relevant anatomical structures were printed using a combination of transparent and opaque resin types. 3D models were used for 7 surgical cases (5 myomectomies, 2 hysterectomies). A staff surgeon and 1 or 2 surgical fellow(s) were present for each case. Surgeons completed a questionnaire before and after receiving the model documenting surgical approach, perceived difficulty, and confidence in surgical plan. A postoperative questionnaire was used to assess surgeon experience using 3D models. RESULTS: Two staff surgeons and 3 clinical fellows participated in this study. A total of 15 surgeon responses were collected across the 7 cases. After viewing the models, an increase in perceived surgical difficulty and confidence in surgical plan was reported in 12/15 and 7/15 responses, respectively. Anticipated surgical time had a mean ± SD absolute change of 44.0 ± 47.9 minutes and anticipated blood loss had an absolute change of 100 ± 103.5 cc. 2 of 15 responses report a change in pre-surgical approach. Intra-operative model reference was reported to change the dissection route in 8/15 surgeon responses. On average, surgeons rated their experience using 3D models 8.6/10 for pre-surgical planning and 8.1/10 for intra-operative reference. CONCLUSIONS: Patient-specific 3D anatomical models may be a useful tool to increase a surgeon's understanding of complex gynaecologic anatomy and to improve their surgical plan. Future work is needed to evaluate the impact of 3D models on surgical outcomes in gynaecology.


Asunto(s)
Imagen por Resonancia Magnética , Modelos Anatómicos , Impresión Tridimensional , Útero , Humanos , Femenino , Útero/cirugía , Útero/diagnóstico por imagen , Útero/anatomía & histología , Neoplasias Uterinas/cirugía , Neoplasias Uterinas/diagnóstico por imagen , Miomectomía Uterina/métodos , Histerectomía/métodos , Leiomioma/cirugía , Leiomioma/diagnóstico por imagen , Leiomioma/patología , Adulto , Cirujanos
3.
Radiology ; 307(1): e212611, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36378033

RESUMEN

Background Global consumption of marijuana is increasing, but there is a paucity of evidence concerning associated lung imaging findings. Purpose To use chest CT to investigate the effects of marijuana smoking in the lung. Materials and Methods This retrospective case-control study evaluated results of chest CT examinations (from October 2005 to July 2020) in marijuana smokers, nonsmoker control patients, and tobacco-only smokers. We compared rates of emphysema, airway changes, gynecomastia, and coronary artery calcification. Age- and sex-matched subgroups were created for comparison with tobacco-only smokers older than 50 years. Results were analyzed using χ2 tests. Results A total of 56 marijuana smokers (34 male; mean age, 49 years ± 14 [SD]), 57 nonsmoker control patients (32 male; mean age, 49 years ± 14), and 33 tobacco-only smokers (18 male; mean age, 60 years ± 6) were evaluated. Higher rates of emphysema were seen among marijuana smokers (42 of 56 [75%]) than nonsmokers (three of 57 [5%]) (P < .001) but not tobacco-only smokers (22 of 33 [67%]) (P = .40). Rates of bronchial thickening, bronchiectasis, and mucoid impaction were higher among marijuana smokers compared with the other groups (P < .001 to P = .04). Gynecomastia was more common in marijuana smokers (13 of 34 [38%]) than in control patients (five of 32 [16%]) (P = .039) and tobacco-only smokers (two of 18 [11%]) (P = .040). In age-matched subgroup analysis of 30 marijuana smokers (23 male), 29 nonsmoker control patients (17 male), and 33 tobacco-only smokers (18 male), rates of bronchial thickening, bronchiectasis, and mucoid impaction were again higher in the marijuana smokers than in the tobacco-only smokers (P < .001 to P = .006). Emphysema rates were higher in age-matched marijuana smokers (28 of 30 [93%]) than in tobacco-only smokers (22 of 33 [67%]) (P = .009). There was no difference in rate of coronary artery calcification between age-matched marijuana smokers (21 of 30 [70%]) and tobacco-only smokers (28 of 33 [85%]) (P = .16). Conclusion Airway inflammation and emphysema were more common in marijuana smokers than in nonsmokers and tobacco-only smokers, although variable interobserver agreement and concomitant cigarette smoking among the marijuana-smoking cohort limits our ability to draw strong conclusions. © RSNA, 2022 See also the editorial by Galvin and Franks in this issue.


Asunto(s)
Bronquiectasia , Cannabis , Enfisema , Ginecomastia , Enfisema Pulmonar , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Estudios de Casos y Controles , Fumadores , Tomografía Computarizada por Rayos X
4.
Radiology ; 307(2): e222483, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36809215

RESUMEN

Background There is no consensus regarding the relative prognostic value of cardiac MRI and fluorodeoxyglucose (FDG) PET in cardiac sarcoidosis. Purpose To perform a systematic review and meta-analysis of the prognostic value of cardiac MRI and FDG PET for major adverse cardiac events (MACE) in cardiac sarcoidosis. Materials and Methods In this systematic review, MEDLINE, Ovid Epub, CENTRAL, Embase, Emcare, and Scopus were searched from inception until January 2022. Studies that evaluated the prognostic value of cardiac MRI or FDG PET in adults with cardiac sarcoidosis were included. The primary outcome of MACE was assessed as a composite including death, ventricular arrhythmia, and heart failure hospitalization. Summary metrics were obtained using random-effects meta-analysis. Meta-regression was used to assess covariates. Risk of bias was assessed using the Quality in Prognostic Studies, or QUIPS, tool. Results Thirty-seven studies were included (3489 patients with mean follow-up of 3.1 years ± 1.5 [SD]); 29 studies evaluated MRI (2931 patients) and 17 evaluated FDG PET (1243 patients). Five studies directly compared MRI and PET in the same patients (276 patients). Left ventricular late gadolinium enhancement (LGE) at MRI and FDG uptake at PET were both predictive of MACE (odds ratio [OR], 8.0 [95% CI: 4.3, 15.0] [P < .001] and 2.1 [95% CI: 1.4, 3.2] [P < .001], respectively). At meta-regression, results varied by modality (P = .006). LGE (OR, 10.4 [95% CI: 3.5, 30.5]; P < .001) was also predictive of MACE when restricted to studies with direct comparison, whereas FDG uptake (OR, 1.9 [95% CI: 0.82, 4.4]; P = .13) was not. Right ventricular LGE and FDG uptake were also associated with MACE (OR, 13.1 [95% CI: 5.2, 33] [P < .001] and 4.1 [95% CI: 1.9, 8.9] [P < .001], respectively). Thirty-two studies were at risk for bias. Conclusion Left and right ventricular late gadolinium enhancement at cardiac MRI and fluorodeoxyglucose uptake at PET were predictive of major adverse cardiac events in cardiac sarcoidosis. Limitations include few studies with direct comparison and risk of bias. Systematic review registration no. CRD42021214776 (PROSPERO) © RSNA, 2023 Supplemental material is available for this article.


Asunto(s)
Cardiomiopatías , Miocarditis , Sarcoidosis , Adulto , Humanos , Fluorodesoxiglucosa F18 , Pronóstico , Cardiomiopatías/diagnóstico por imagen , Medios de Contraste , Gadolinio , Imagen por Resonancia Magnética , Sarcoidosis/diagnóstico por imagen
5.
Radiology ; 307(3): e221437, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36916896

RESUMEN

Systematic reviews of diagnostic accuracy studies can provide the best available evidence to inform decisions regarding the use of a diagnostic test. In this guide, the authors provide a practical approach for clinicians to appraise diagnostic accuracy systematic reviews and apply their results to patient care. The first step is to identify an appropriate systematic review with a research question matching the clinical scenario. The user should evaluate the rigor of the review methods to evaluate its credibility (Did the review use clearly defined eligibility criteria, a comprehensive search strategy, structured data collection, risk of bias and applicability appraisal, and appropriate meta-analysis methods?). If the review is credible, the next step is to decide whether the diagnostic performance is adequate for clinical use (Do sensitivity and specificity estimates exceed the threshold that makes them useful in clinical practice? Are these estimates sufficiently precise? Is variability in the estimates of diagnostic accuracy across studies explained?). Diagnostic accuracy systematic reviews that are judged to be credible and provide diagnostic accuracy estimates with sufficient certainty and relevance are the most useful to inform patient care. This review discusses comparative, noncomparative, and emerging approaches to systematic reviews of diagnostic accuracy using a clinical scenario and examples based on recent publications.


Asunto(s)
Diagnóstico , Metaanálisis como Asunto , Revisiones Sistemáticas como Asunto , Humanos , Sensibilidad y Especificidad
6.
Radiology ; 309(3): e231656, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38112549

RESUMEN

Background A simplification of the Liver Imaging Reporting and Data System (LI-RADS) version 2018 (v2018), revised LI-RADS (rLI-RADS), has been proposed for imaging-based diagnosis of hepatocellular carcinoma (HCC). Single-site data suggest that rLI-RADS category 5 (rLR-5) improves sensitivity while maintaining positive predictive value (PPV) of the LI-RADS v2018 category 5 (LR-5), which indicates definite HCC. Purpose To compare the diagnostic performance of LI-RADS v2018 and rLI-RADS in a multicenter data set of patients at risk for HCC by performing an individual patient data meta-analysis. Materials and Methods Multiple databases were searched for studies published from January 2014 to January 2022 that evaluated the diagnostic performance of any version of LI-RADS at CT or MRI for diagnosing HCC. An individual patient data meta-analysis method was applied to observations from the identified studies. Quality Assessment of Diagnostic Accuracy Studies version 2 was applied to determine study risk of bias. Observations were categorized according to major features and either LI-RADS v2018 or rLI-RADS assignments. Diagnostic accuracies of category 5 for each system were calculated using generalized linear mixed models and compared using the likelihood ratio test for sensitivity and the Wald test for PPV. Results Twenty-four studies, including 3840 patients and 4727 observations, were analyzed. The median observation size was 19 mm (IQR, 11-30 mm). rLR-5 showed higher sensitivity compared with LR-5 (70.6% [95% CI: 60.7, 78.9] vs 61.3% [95% CI: 45.9, 74.7]; P < .001), with similar PPV (90.7% vs 92.3%; P = .55). In studies with low risk of bias (n = 4; 1031 observations), rLR-5 also achieved a higher sensitivity than LR-5 (72.3% [95% CI: 63.9, 80.1] vs 66.9% [95% CI: 58.2, 74.5]; P = .02), with similar PPV (83.1% vs 88.7%; P = .47). Conclusion rLR-5 achieved a higher sensitivity for identifying HCC than LR-5 while maintaining a comparable PPV at 90% or more, matching the results presented in the original rLI-RADS study. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Sirlin and Chernyak in this issue.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Medios de Contraste , Sensibilidad y Especificidad , Estudios Multicéntricos como Asunto
7.
J Magn Reson Imaging ; 57(4): 1172-1184, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36054467

RESUMEN

BACKGROUND: Biparametric (bp)-MRI and multiparametric (mp)-MRI may improve the diagnostic accuracy of renal mass histology. PURPOSE: To evaluate the available evidence on the diagnostic accuracy of bp-MRI and mp-MRI for solid renal masses in differentiating malignant from benign, aggressive from indolent, and clear cell renal cell carcinoma (ccRCC) from other histology. STUDY TYPE: Systematic review. POPULATION: MEDLINE, EMBASE, and CENTRAL up to January 11, 2022 were searched. FIELD STRENGTH/SEQUENCE: 1.5 or 3 Tesla. ASSESSMENT: Eligible studies evaluated the accuracy of MRI (with at least two sequences: T2, T1, dynamic contrast and diffusion-weighted imaging) for diagnosis of solid renal masses in adult patients, using histology as reference standard. Risk of bias and applicability were assessed using QUADAS-2. STATISTICAL TESTS: Meta-analysis using a bivariate logitnormal random effects model. RESULTS: We included 10 studies (1239 masses from approximately 1200 patients). The risk of bias was high in three studies, unclear in five studies and low in two studies. The diagnostic accuracy of malignant (vs. benign) masses was assessed in five studies (64% [179/281] malignant). The summary estimate of sensitivity was 95% (95% confidence interval [CI]: 77%-99%), and specificity was 63% (95% CI: 46%-77%). No study assessed aggressive (vs. indolent) masses. The diagnostic accuracy of ccRCC (vs. other subtypes) was evaluated in six studies (47% [455/971] ccRCC): the summary estimate of sensitivity was 85% (95% CI: 77%-90%) and specificity was 77% (95% CI: 73%-81%). DATA CONCLUSION: Our study reveals deficits in the available evidence on MRI for diagnosis of renal mass histology. The number of studies was limited, at unclear/high risk of bias, with heterogeneous definitions of solid masses, imaging techniques, diagnostic criteria, and outcome measures. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Adulto , Humanos , Sensibilidad y Especificidad , Imagen por Resonancia Magnética , Imagen de Difusión por Resonancia Magnética
8.
J Magn Reson Imaging ; 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37818955

RESUMEN

Medical imaging diagnostic test accuracy research is strengthened by adhering to best practices for study design, data collection, data documentation, and study reporting. In this review, key elements of such research are discussed, and specific recommendations provided for optimizing diagnostic accuracy study execution to improve uniformity, minimize common sources of bias and avoid potential pitfalls. Examples are provided regarding study methodology and data collection practices based on insights gained by the liver imaging reporting and data system (LI-RADS) individual participant data group, who have evaluated raw data from numerous MRI diagnostic accuracy studies for risk of bias and data integrity. The goal of this review is to outline strategies for investigators to improve research practices, and to help reviewers and readers better contextualize a study's findings while understanding its limitations. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 3.

9.
J Magn Reson Imaging ; 57(5): 1567-1575, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36151888

RESUMEN

BACKGROUND: Pancreatic cystic lesions (PCLs) are followed for years due to older and likely biased works demonstrating a strong association with pancreatic carcinoma; more recent data are needed clarifying this relationship. PURPOSE: To determine the association between PCLs on MRI and a synchronous or future diagnosis of pancreatic carcinoma. STUDY TYPE: Single-center retrospective cohort. POPULATION: A total of 192 patients (111 female, 58%) with median age 66 years (range 26-87 years) with PCLs on abdominal MRI from 2011 to 2016. FIELD STRENGTH/SEQUENCES: 1.5 T and 3 T, including T2 WI, T1 WI, diffusion weighted imaging and contrast-enhanced T1 WI. ASSESSMENT: Each PCL was reviewed independently by 2 of 10 fellowship-trained abdominal radiologists. Fukuoka guideline worrisome features and high-risk stigmata were evaluated. Follow-up imaging and clinical notes were reviewed within a system that captures pancreatic carcinoma for the region, for a median follow-up of 67 months (interquartile range: 43-88 months). STATISTICAL TESTS: Pancreatic carcinoma prevalence and incidence rate for future carcinoma with 95% confidence intervals (95% CI). Fisher exact test, logistic regression with odds ratios (OR) and the Wilcoxon rank-sum test were used to assess PCL morphologic features with the Kolmogorov-Smirnov test used to assess for normality. P < 0.05 defined statistical significance. RESULTS: The prevalence of pancreatic carcinoma on initial MRI showing a PCL was 2.4% (95% CI: 0.9%, 5.2%). Thickened/enhancing cyst wall was associated with pancreatic carcinoma, OR 52 (95% CI: 4.5, 1203). Of 189 patients with a PCL but without pancreatic carcinoma at the time of initial MRI, one developed high-grade dysplasia and none developed invasive carcinoma for an incidence rate of 0.97 (95% CI: 0.02, 5.43) and 0 (95% CI: 0, 3.59) cases per 1000 person-years, respectively. DATA CONCLUSION: A low percentage of patients with a PCL on MRI had a pancreatic carcinoma at the time of initial evaluation and none developed carcinoma over a median 67 months of follow-up. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: 5.


Asunto(s)
Carcinoma , Quiste Pancreático , Neoplasias Pancreáticas , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estudios Retrospectivos , Quiste Pancreático/complicaciones , Quiste Pancreático/patología , Neoplasias Pancreáticas/patología , Imagen por Resonancia Magnética , Neoplasias Pancreáticas
10.
J Magn Reson Imaging ; 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38053468

RESUMEN

BACKGROUND: Pancreatic cystic lesions (PCLs) are frequent on MRI and are thought to be associated with pancreatic adenocarcinoma (PDAC) necessitating long-term surveillance based on older studies suffering from selection bias. PURPOSE: To establish the percentage of patients with PCLs on MRI with a present or future PDAC. STUDY TYPE: Systematic review, meta-analysis. POPULATION: Adults with PCLs on MRI and a present or future diagnosis of PDAC were eligible. MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and Scopus were searched to April 2022 (PROSPERO:CRD42022320502). Studies limited to PCLs not requiring surveillance, <100 patients, or those with a history/genetic risk of PDAC were excluded. FIELD STRENGTH/SEQUENCE: ≥1.5 T with ≥1 T2-weighted sequence. ASSESSMENT: Two investigators extracted data, with discrepancies resolved by a third. QUADAS-2 assessed bias. PDAC was diagnosed using a composite reference standard. STATISTICAL TESTS: A meta-analysis of proportions was performed at the patient-level with 95% confidence intervals (95% CI). RESULTS: Eight studies with 1289 patients contributed to the percentage of patients with a present diagnosis of PDAC, and 10 studies with 3422 patients to the percentage with a future diagnosis. Of patients with PCLs on MRI, 14.8% (95% CI 2.4-34.9) had a PDAC at initial MRI, which decreased to 6.0% (2.2-11.3) for studies at low risk of bias. For patients without PDAC on initial MRI, 2.0% (1.1-3.2) developed PDAC during surveillance, similar for low risk of bias studies at 1.9% (0.7-3.6), with no clear trend of increased PDAC for longer surveillance durations. For patients without worrisome features or high-risk stigmata, 0.9% (0.1-2.2) developed PDAC during surveillance. Of 10, eight studies had a median surveillance ≥3 years (range 3-157 months). Sources of bias included retrospectively limiting PCLs to those with histopathology and inconsistent surveillance protocols. DATA CONCLUSION: A low percentage of patients with PCLs on MRI develop PDAC while on surveillance. The first MRI revealing a PCL should be scrutinized for PDAC. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

11.
J Magn Reson Imaging ; 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38038346

RESUMEN

BACKGROUND: LI-RADS version 2018 (v2018) is used for non-invasive diagnosis of hepatocellular carcinoma (HCC). A recently proposed modification (known as mLI-RADS) demonstrated improved sensitivity while maintaining specificity and positive predictive value (PPV) of LI-RADS category 5 (definite HCC) for HCC. However, mLI-RADS requires multicenter validation. PURPOSE: To evaluate the performance of v2018 and mLI-RADS for liver lesions in a large, heterogeneous, multi-national cohort of patients at risk for HCC. STUDY TYPE: Systematic review and meta-analysis using individual participant data (IPD) [Study Protocol: https://osf.io/duys4]. POPULATION: 2223 observations from 1817 patients (includes all LI-RADS categories; females = 448, males = 1361, not reported = 8) at elevated risk for developing HCC (based on LI-RADS population criteria) from 12 retrospective studies. FIELD STRENGTH/SEQUENCE: 1.5T and 3T; complete liver MRI with gadoxetate disodium, including axial T2w images and dynamic axial fat-suppressed T1w images precontrast and in the arterial, portal venous, transitional, and hepatobiliary phases. Diffusion-weighted imaging was used when available. ASSESSMENT: Liver observations were categorized using v2018 and mLI-RADS. The diagnostic performance of each system's category 5 (LR-5 and mLR-5) for HCC were compared. STATISTICAL TESTS: The Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2 was applied to determine risk of bias and applicability. Diagnostic performances were assessed using the likelihood ratio test for sensitivity and specificity and the Wald test for PPV. The significance level was P < 0.05. RESULTS: 17% (2/12) of the studies were considered low risk of bias (244 liver observations; 164 patients). When compared to v2018, mLR-5 demonstrated higher sensitivity (61.3% vs. 46.5%, P < 0.001), similar PPV (85.3% vs. 86.3%, P = 0.89), and similar specificity (85.8% vs. 90.8%, P = 0.16) for HCC. DATA CONCLUSION: This study confirms mLR-5 has higher sensitivity than LR-5 for HCC identification, while maintaining similar PPV and specificity, validating the mLI-RADS proposal in a heterogeneous, international cohort. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

12.
J Magn Reson Imaging ; 57(1): 308-317, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35512243

RESUMEN

BACKGROUND: There is a sparsity of data evaluating outcomes of patients with Liver Imaging Reporting and Data System (LI-RADS) (LR)-M lesions. PURPOSE: To compare overall survival (OS) and progression free survival (PFS) between hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (iCCA) meeting LR-M criteria and to evaluate factors associated with prognosis. STUDY TYPE: Retrospective. SUBJECTS: Patients at risk for HCC with at least one LR-M lesion with histologic diagnosis, from 8 academic centers, yielding 120 patients with 120 LR-M lesions (84 men [mean age 62 years] and 36 women [mean age 66 years]). FIELD STRENGTH/SEQUENCE: A 1.5 and 3.0 T/3D T1 -weighted gradient echo, T2 -weighted fast spin-echo. ASSESSMENT: The imaging categorization of each lesion as LR-M was made clinically by a single radiologist at each site and patient outcome measures were collected. STATISTICAL TESTS: OS, PFS, and potential independent predictors were evaluated by Kaplan-Meier method, log-rank test, and Cox proportional hazard model. A P value of <0.05 was considered significant. RESULTS: A total of 120 patients with 120 LR-M lesions were included; on histology 65 were HCC and 55 were iCCA. There was similar median OS for patients with LR-M HCC compared to patients with iCCA (738 days vs. 769 days, P = 0.576). There were no significant differences between patients with HCC and iCCA in terms of sex (47:18 vs. 37:18, P = 0.549), age (63.0 ± 8.4 vs. 63.4 ± 7.8, P = 0.847), etiology of liver disease (P = 0.202), presence of cirrhosis (100% vs. 100%, P = 1.000), tumor size (4.73 ± 3.28 vs. 4.75 ± 2.58, P = 0.980), method of lesion histologic diagnosis (P = 0.646), and proportion of patients who underwent locoregional therapy (60.0% vs. 38.2%, P = 0.100) or surgery (134.8 ± 165.5 vs. 142.5 ± 205.6, P = 0.913). Using multivariable analysis, nonsurgical compared to surgical management (HR, 4.58), larger tumor size (HR, 1.19), and higher MELD score (HR, 1.12) were independently associated with worse OS. DATA CONCLUSION: There was similar OS in patients with LR-M HCC and LR-M iCCA, suggesting that LR-M imaging features may more closely reflect patient outcomes than histology. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 5.


Asunto(s)
Neoplasias de los Conductos Biliares , Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/cirugía , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Colangiocarcinoma/diagnóstico por imagen , Neoplasias de los Conductos Biliares/diagnóstico por imagen , Conductos Biliares Intrahepáticos , Medios de Contraste
13.
Eur Radiol ; 33(2): 1307-1317, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35999371

RESUMEN

OBJECTIVES: Determine the proportion of malignancy within Bosniak v2019 classes. METHODS: MEDLINE and EMBASE were searched. Eligible studies contained patients with cystic renal masses undergoing CT or MRI renal protocol examinations with pathology confirmation, applying Bosniak v2019. Proportion of malignancy was estimated within Bosniak v2019 class. Risk of bias was assessed using QUADAS-2. RESULTS: We included 471 patients with 480 cystic renal masses. No class I malignant masses were observed. Pooled proportion of malignancy were class II, 12% (6/51, 95% CI 5-24%); class IIF, 46% (37/85, 95% CI 28-66%); class III, 79% (138/173, 95% CI 68-88%); and class IV, 84% (114/135, 95% CI 77-90%). Proportion of malignancy differed between Bosniak v2019 II-IV classes (p = 0.004). Four studies reported the proportion of malignancy by wall/septa feature. The pooled proportion of malignancy with 95% CI were class III thick smooth wall/septa, 77% (41/56, 95% CI 53-91%); class III obtuse protrusion ≤ 3 mm (irregularity), 83% (97/117, 95% CI 75-89%); and class IV nodule with acute angulation, 86% (50/58, 95% CI 75-93%) or obtuse angulation ≥ 4 mm, 83%, (64/77, 95% CI 73-90%). Subgroup analysis by wall/septa feature was limited by sample size; however, no differences were found comparing class III masses with irregularity to class IV masses (p = 0.74) or between class IV masses by acute versus obtuse angles (p = 0.62). CONCLUSION: Preliminary data suggest Bosniak v2019 class IIF masses have higher proportion of malignancy compared to the original classification, controlling for pathologic reference standard. There are no differences in proportion of malignancy comparing class III masses with irregularities to class IV masses with acute or obtuse nodules. KEY POINTS: • The proportion of malignancy in Bosniak v2019 class IIF cystic masses is 46% (37 malignant/85 total IIF masses, 95% confidence intervals (CI) 28-66%). • The proportion of malignancy in Bosniak v2019 class III cystic masses is 79% (138/173, 95% CI 68-88%) and in Bosniak v2019 class IV cystic masses is 84% (114/135, 95% CI 77-90%). • Class III cystic masses with irregularities had similar proportion of malignancy (83%, 97/117, 95% CI 75-89%) compared to Bosniak class IV masses (84%, 114/135, 95% CI 77-90%) overall (p = 0.74) with no difference within class IV masses by acute versus obtuse angulation (p = 0.62).


Asunto(s)
Carcinoma de Células Renales , Enfermedades Renales Quísticas , Neoplasias Renales , Humanos , Enfermedades Renales Quísticas/diagnóstico por imagen , Enfermedades Renales Quísticas/epidemiología , Tomografía Computarizada por Rayos X/métodos , Riñón/patología , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/epidemiología , Carcinoma de Células Renales/patología , Estudios Retrospectivos
14.
AJR Am J Roentgenol ; 220(1): 28-38, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35920706

RESUMEN

BACKGROUND. Accumulating evidence indicates that hepatocellular adenoma (HCA) may have a higher frequency of hepatobiliary phase (HBP) iso- or hyperintensity than previously reported. OBJECTIVE. The purpose of this study was to evaluate the proportion of HCA that shows iso- or hyperintensity in the HBP of gadoxetic acid-enhanced MRI, stratified by HCA subtype (HNF1a-inactivated [H-HCA], inflammatory [I-HCA], ß-catenin-activated [B-HCA], and unclassified [U-HCA] HCA), and to assess the diagnostic performance of HBP iso- or hyperintensity for differentiating focal nodular hyperplasia (FNH) from HCA. EVIDENCE ACQUISITION. PubMed, Embase, and Cochrane Central Register of Controlled Trials were searched through February 14, 2022, for articles reporting HBP signal intensity on gadoxetic acid-enhanced MRI among pathologically proven HCAs, stratified by subtype. The pooled proportion of HBP iso- or hyperintensity was determined for each subtype and compared using metaregression. Diagnostic performance of HBP iso- or hyperintensity for differentiating FNH from all HCA subtypes combined and from B-HCA and U-HCA combined was assessed using bivariate modeling. EVIDENCE SYNTHESIS. Twenty-eight studies (12 original investigations, 16 case reports or case series) were included, yielding 364 patients with 410 HCAs (112 H-HCAs, 203 I-HCAs, 33 B-HCAs, 62 U-HCAs). Pooled proportion of HBP iso- or hyperintensity was 14% (95% CI, 4-26%) among all HCAs, 0% (95% CI, 0-2%) among H-HCAs, 11% (95% CI, 0-29%) among U-HCAs, 14% (95% CI, 2-31%) among I-HCAs, and 59% (95% CI, 26-88%) among B-HCAs; metaregression showed significant difference among subtypes (p < .001). In four studies reporting diagnostic performance information, HBP iso- or hyperintensity had sensitivity of 99% (95% CI, 57-100%) and specificity of 89% (95% CI, 82-94%) for differentiating FNH from all HCA subtypes and sensitivity of 99% (95% CI, 53-100%) and specificity of 65% (95% CI, 44-80%) for differentiating FNH from B-HCA or U-HCA. CONCLUSION. HCA subtypes other than H-HCA show proportions of HBP iso- or hyperintensity ranging from 11% (U-HCA) to 59% (B-HCA). Low prevalence of B-HCA has contributed to prior reports of high diagnostic performance of HBP iso- or hyperintensity for differentiating FNH from HCA. CLINICAL IMPACT. Radiologists should recognize the low specificity of HBP iso- or hyperintensity on gadoxetic acid-enhanced MRI for differentiating FNH from certain HCA subtypes.


Asunto(s)
Adenoma de Células Hepáticas , Hiperplasia Nodular Focal , Neoplasias Hepáticas , Humanos , Adenoma de Células Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Medios de Contraste , Sensibilidad y Especificidad , Gadolinio DTPA , Imagen por Resonancia Magnética , Aminas , Estudios Retrospectivos , Diagnóstico Diferencial
15.
J Intensive Care Med ; 38(3): 245-272, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35854414

RESUMEN

BACKGROUND: Critical care transesophageal echocardiography (ccTEE) is an increasingly popular tool used by intensivists to characterize and manage hemodynamics at the bedside. Its usage appears to be driven by expanded diagnostic scope as well as the limitations of transthoracic echocardiography (TTE) - lack of acoustic windows, patient positioning, and competing clinical interests (eg, the need to perform chest compressions). The objectives of this scoping review were to determine the indications, clinical impact, and complications of ccTEE. METHODS: MEDLINE, EMBASE, Cochrane, and six major conferences were searched without a time or language restriction on March 31st, 2021. Studies were included if they assessed TEE performed for adult critically ill patients by intensivists, emergency physicians, or anesthesiologists. Intraoperative or post-cardiac surgical TEE studies were excluded. Study demographics, indication for TEE, main results, and complications were extracted in duplicate. RESULTS: Of the 4403 abstracts screened, 289 studies underwent full-text review, with 108 studies (6739 patients) included. Most studies were retrospective (66%), performed in academic centers (84%), in the intensive care unit (73%), and were observational (55%). The most common indications for ccTEE were hemodynamic instability, trauma, cardiac arrest, respiratory failure, and procedural guidance. Across multiple indications, ccTEE was reported to change the diagnosis in 52% to 78% of patients and change management in 32% to79% patients. During cardiac arrest, ccTEE identified the cause of arrest in 25% to 35% of cases. Complications of ccTEE included two cases of significant gastrointestinal bleeding requiring intervention, but no other major complications (death or esophageal perforation) reported. CONCLUSIONS: The use of ccTEE has been described for the diagnosis and management of a broad range of clinical problems. Overall, ccTEE was commonly reported to offer additional diagnostic yield beyond TTE with a low observed complication rate. Additional high quality ccTEE studies will permit stronger conclusions and a more precise understanding of the trends observed in this scoping review.


Asunto(s)
Ecocardiografía Transesofágica , Paro Cardíaco , Adulto , Humanos , Ecocardiografía Transesofágica/efectos adversos , Estudios Retrospectivos , Ecocardiografía/métodos , Cuidados Críticos , Paro Cardíaco/etiología , Paro Cardíaco/terapia
16.
J Comput Assist Tomogr ; 47(1): 160-164, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36112014

RESUMEN

RATIONALE AND OBJECTIVES: Our purpose is to explore the role of dual-energy computed tomography (DECT) and virtual monoenergetic energy levels in reducing shoulder artifact to improve visualization of the cervical spinal canal. MATERIALS AND METHODS: A retrospective review of 171 consecutive DECT scans of the neck (95 male, 65 female; mean age, 60.9 years, ranging from 18 to 88 years; with 11 excluded because of nondiagnostic image quality) during an 8-month period was performed with postprocessing of monoenergetic images at 50, 70, 100, and 140 keV. Subjective comparisons and objective image noise between the monoenergetic images and standard computed tomography (CT) were analyzed by 1-way analysis of variance to determine the optimal DECT energy level with the highest image quality. RESULTS: Subjectively, 100-keV DECT best visualizes the spinal canal relative to standard CT, 50 and 70 keV ( P < 0.01), and was superior to 140 keV for reader 1 ( P < 0.01). Objectively, 100 keV demonstrated less noise relative to 50 keV (72.02; P < 0.01). There was no difference in noise between 100 keV and 70 keV, or between 100 keV and standard CT, which also demonstrated lower noise relative to 50-, 70-, and 140-keV levels (91.53, P < 0.01; 29.84, P < 0.01; and 22.66, P < 0.03). CONCLUSION: Dual-energy CT at 100 keV may be the preferred DECT monoenergetic level for soft tissue assessment. Increasing energy level is associated with reduction in shoulder artifact, with no difference in noise between 100 keV and standard CT, although 100-keV images may be subjectively better.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Masculino , Femenino , Persona de Mediana Edad , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Cuello , Estudios Retrospectivos , Canal Medular/diagnóstico por imagen , Relación Señal-Ruido , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
17.
Alzheimers Dement ; 19(7): 3235-3243, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36934438

RESUMEN

INTRODUCTION: This systematic review evaluates the accuracy of the Montreal Cognitive Assessment (MoCA) for detecting mild cognitive impairment (MCI). METHODS: We searched MEDLINE, PSYCInfo, EMBASE, and Cochrane CENTRAL (1995-2021) for studies comparing the MoCA with validated diagnostic criteria to identify MCI in general practice. Screening, data extraction, and risk of bias assessment were performed independently, in duplicate. Pooled sensitivity and specificity for MoCA cutoffs were estimated using bivariate meta-analysis. RESULTS: Thirteen studies [2158 participants, 948(44%) with MCI] were included; 10 used Petersen criteria as the reference standard. Risk of bias of studies were high or unclear for all domains except reference standard. Sensitivity and specificity were 73.5%(95% confidence interval: 56.7-85.5) and 91.3%(84.6-95.3) at cutoff <23; 79.5%(67.1-88.0) and 83.7%(75.4-89.6) at cutoff <24; and 83.8%(75.6-89.6) and 70.8(62.1-78.3) at cutoff <25. DISCUSSION: MoCA cutoffs <23 to <25 maximized the sum of sensitivity and specificity for detecting MCI. The risk of bias of included studies limits confidence in these findings.


Asunto(s)
Disfunción Cognitiva , Humanos , Disfunción Cognitiva/diagnóstico , Disfunción Cognitiva/psicología , Pruebas de Estado Mental y Demencia , Sensibilidad y Especificidad , Examen Neurológico , Pruebas Neuropsicológicas
18.
Can Assoc Radiol J ; 74(4): 635-642, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36942645

RESUMEN

Objectives: To investigate intra-specialty citation patterns of radiology articles, compared with another medical specialty: gastroenterology/hepatology. Methods: Four radiology journals (Radiology, European Radiology, Diagnostic and Interventional Imaging, Canadian Association of Radiologists Journal) and four gastroenterology/hepatology journals (Journal of Hepatology, Journal of Gastroenterology, World Journal of Gastroenterology, Journal of Clinical Gastroenterology) with similar Web of Science in-category 2020 IF ranking were selected. The original research, review, letter, and editorial articles published in these journals in 2021 were identified. The average number of intra-specialty citations per article (intra-specialty citation count) and percentage of intra-specialty citations out of total citations per article (intra-specialty citation rate) were compared between radiology and gastroenterology/hepatology articles using Student's t-test. Results: The radiology articles demonstrated a lower total citation count per article (radiology: 29.7 ± .4 (mean ± SEM), n = 2063; gastroenterology/hepatology: 50.1 ± 1.4, n = 1335). The intra-specialty citation count was also lower in radiology articles than gastroenterology/hepatology articles (radiology: 12.9 ± .2, gastroenterology/hepatology: 19.6 ± .7; P < .001), both overall and in all article types. Additionally, the overall intra-specialty citation rate was not significantly different between the two specialties (radiology: 48.8% ± .5%; gastroenterology/hepatology: 47.1 ± .8%; P = .057), although the intra-specialty citation rates were higher in radiology original research and editorial article types. Conclusions: The significantly lower per-article intra-specialty citation counts in all radiology article types, a measurement that directly links to specialty IFs, may contribute to the lower impact factors of radiology journals compared with gastroenterology/hepatology ones.


Asunto(s)
Gastroenterología , Publicaciones Periódicas como Asunto , Radiología , Humanos , Canadá , Radiografía
19.
Can Assoc Radiol J ; 74(2): 334-342, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36301600

RESUMEN

Purpose: To establish reporting adherence to the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) in diagnostic accuracy AI studies with the highest Altmetric Attention Scores (AAS), and to compare completeness of reporting between peer-reviewed manuscripts and preprints. Methods: MEDLINE, EMBASE, arXiv, bioRxiv, and medRxiv were retrospectively searched for 100 diagnostic accuracy medical imaging AI studies in peer-reviewed journals and preprint platforms with the highest AAS since the release of CLAIM to June 24, 2021. Studies were evaluated for adherence to the 42-item CLAIM checklist with comparison between peer-reviewed manuscripts and preprints. The impact of additional factors was explored including body region, models on COVID-19 diagnosis and journal impact factor. Results: Median CLAIM adherence was 48% (20/42). The median CLAIM score of manuscripts published in peer-reviewed journals was higher than preprints, 57% (24/42) vs 40% (16/42), P < .0001. Chest radiology was the body region with the least complete reporting (P = .0352), with manuscripts on COVID-19 less complete than others (43% vs 54%, P = .0002). For studies published in peer-reviewed journals with an impact factor, the CLAIM score correlated with impact factor, rho = 0.43, P = .0040. Completeness of reporting based on CLAIM score had a positive correlation with a study's AAS, rho = 0.68, P < .0001. Conclusions: Overall reporting adherence to CLAIM is low in imaging diagnostic accuracy AI studies with the highest AAS, with preprints reporting fewer study details than peer-reviewed manuscripts. Improved CLAIM adherence could promote adoption of AI into clinical practice and facilitate investigators building upon prior works.


Asunto(s)
COVID-19 , Humanos , Lista de Verificación , Inteligencia Artificial , Prueba de COVID-19 , Estudios Retrospectivos , Diagnóstico por Imagen
20.
Can Assoc Radiol J ; 74(3): 497-507, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36412994

RESUMEN

BACKGROUND: P-hacking, the tendency to run selective analyses until they become significant, is prevalent in many scientific disciplines. PURPOSE: This study aims to assess if p-hacking exists in imaging research. METHODS: Protocol, data, and code available here https://osf.io/xz9ku/?view_only=a9f7c2d841684cb7a3616f567db273fa. We searched imaging journals Ovid MEDLINE from 1972 to 2021. Text mining using Python script was used to collect metadata: journal, publication year, title, abstract, and P-values from abstracts. One P-value was randomly sampled per abstract. We assessed for evidence of p-hacking using a p-curve, by evaluating for a concentration of P-values just below .05. We conducted a one-tailed binomial test (α = .05 level of significance) to assess whether there were more P-values falling in the upper range (e.g., .045 < P < .05) than in the lower range (e.g., .04 < P < .045). To assess variation in results introduced by our random sampling of a single P-value per abstract, we repeated the random sampling process 1000 times and pooled results across the samples. Analysis was done (divided into 10-year periods) to determine if p-hacking practices evolved over time. RESULTS: Our search of 136 journals identified 967,981 abstracts. Text mining identified 293,687 P-values, and a total of 4105 randomly sampled P-values were included in the p-hacking analysis. The number of journals and abstracts that were included in the analysis as a fraction and percentage of the total number was, respectively, 108/136 (80%) and 4105/967,981 (.4%). P-values did not concentrate just under .05; in fact, there were more P-values falling in the lower range (e.g., .04 < P < .045) than falling just below .05 (e.g., .045 < P < .05), indicating lack of evidence for p-hacking. Time trend analysis did not identify p-hacking in any of the five 10-year periods. CONCLUSION: We did not identify evidence of p-hacking in abstracts published in over 100 imaging journals since 1972. These analyses cannot detect all forms of p-hacking, and other forms of bias may exist in imaging research such as publication bias and selective outcome reporting.


Asunto(s)
Sesgo de Publicación , Estadística como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA