Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

País/Región como asunto
País de afiliación
Intervalo de año de publicación
1.
Arq Bras Cardiol ; 120(1): e20220892, 2023 01 23.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-36700596
2.
Arq. bras. cardiol ; 120(1): e20220892, 2023. tab, graf
Artículo en Portugués | LILACS, CONASS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1420149

Asunto(s)
Corazón Auxiliar
3.
Rev Soc Bras Med Trop ; 45(3): 340-5, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22760133

RESUMEN

INTRODUCTION: The septal position is an alternative site for cardiac pacing (CP) that is potentially less harmful to cardiac function. METHODS: Patients with Chagas disease without heart failure submitted to permanent pacemaker (PP) implantation at the Clinics Hospital of the Triângulo Mineiro Federal University (UFTM), were selected from February 2009 to February 2010. The parameters analyzed were ventricular remodeling, the degree of electromechanical dyssynchrony (DEM), exercise time and VO2 max during exercise testing (ET) and functional class (NYHA). Echocardiography was performed 24 to 48 h following implantation and after one year follow-up. The patients were submitted to ET one month postprocedure and at the end of one year. RESULTS: Thirty patients were included. Patient mean age was 59 ± 13 years-old. Indication for PP implantation was complete atrioventricular (AV) block in 22 (73.3%) patients and 2nd degree AV block in the other eight (26.7%). All patients were in NYHA I and no changes occurred in the ET parameters. No variations were detected in echocardiographic remodeling measurements. Intraventricular dyssynchrony was observed in 46.6% of cases and interventricular dyssynchrony in 33.3% of patients after one year. CONCLUSIONS: The findings of this work suggest that there is not significant morphological and functional cardiac change following pacemaker implantation in septal position in chagasic patients with normal left ventricular function after one year follow-up. Thus, patients may remain asymptomatic, presenting maintenance of functional capacity and no left ventricular remodeling.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Cardiomiopatía Chagásica/terapia , Marcapaso Artificial , Adolescente , Adulto , Anciano , Ecocardiografía , Electrocardiografía , Prueba de Esfuerzo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Tabique Interventricular , Adulto Joven
4.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 30(1): 3-8, jan.-mar. 2017. ilus, graf
Artículo en Portugués | LILACS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-837227

RESUMEN

Introdução: Este trabalho teve por objetivos identificar as características comuns aos geradores e classificá-los no menor número possível de grupos para facilitar a identificação radiológica, e, também, identificar características que permitam diferenciar geradores DF1 de DF4. Método: A amostragem foi composta por 62 imagens de geradores de dispositivos implantáveis bem como de cabos-eletrodos comercialmente disponíveis no Brasil de 2008 até o presente momento das empresas Biotronik, Medtronic, St. Jude Medical e Boston Scientific. As imagens consideradas com qualidade adequada de cada modelo de dispositivo implantável foram selecionadas em busca de características comuns a cada fabricante. Resultados: A revisão criteriosa das características de cada fabricante e modelo possibilitou divisar claramente oito categorias, com características únicas de cada fabricante para estimuladores (grupo 1) e cardiodesfibriladores (grupo 2). Um algoritmo de identificação foi desenvolvido, a partir das características mais facilmente identificáveis de cada grupo. Conclusão: A identificação radiológica dos dispositivos implantáveis é possível e confiável. Os cabos-eletrodos de mesma função (choque ou estimulação) não puderam ser diferenciados em relação ao fabricante, mas algumas características das conexões de cabos-eletrodos de choque podem diferenciar a conexão DF1 de DF4, bem como mono coil de duplo coil


Background: This study is aimed at identifying common characteristics of generators and classify them into the lowest possible number of groups to facilitate X-ray identification as well as to identify characteristics to differentiate DF1 and DF4 generators. Method: The sample included 62 images of implantable device generators and leads available in the Brazilian market from 2008 to the present moment manufactured by Biotronik, Medtronic, St. Jude Medical and Boston Scientific. Good quality images from each implantable device model were chosen to help identify common characteristics of each manufacturer. Results: A careful review of manufacturer's characteristics and model enabled a clear division into eight categories with each manufacturer's unique characteristics for pacers (group 1) and cardiac defibrillators (group 2). An identification algorhythm was developed based on the most easily identifiable characteristics of each group. Conclusion: X-ray identification of implantable devices is possible and reliable. Leads with the same function (shock or pacing) were not differentiated by manufacturer, but some shock lead connection characteristics may differentiate DF1 from DF4 connections, as well monocoil from double coil


Asunto(s)
Humanos , Rayos X , Radiografía/métodos , Desfibriladores Implantables/tendencias , Marcapaso Artificial , Electrodos/normas , Dispositivos de Terapia de Resincronización Cardíaca/tendencias , Industrias/normas
5.
Arq Bras Cardiol ; 96(1): 76-85, 2011 Jan.
Artículo en Inglés, Portugués, Español | MEDLINE | ID: mdl-21308340

RESUMEN

The conventional right ventricular stimulation can be associated with deleterious effects on cardiac function. The need for a more physiological artificial cardiac stimulation is undoubtedly one of the most important points in the area of cardiac electrotherapy. The programming algorithms for the maintenance of adequate atrioventricular conduction, the stimulation of alternative endocardial sites and the cardiac resynchronization therapy are used with the objective of attaining these goals. The stimulation of the bundle of His and the septal stimulation have been studied as alternative endocardial sites for the positioning of the electrode on the right ventricle. The septal stimulation represents a simple and practical alternative, with no additional costs involved and with potential benefits in decreasing the deleterious effects of the right ventricular stimulation. However, this alternative site involves a heterogeneous group of patients and presents conflicting results regarding its long-term clinical benefit. This article reviews the scientific evidence on the alternative sites for right ventricular stimulation, with emphasis on the safety of the procedure, the measurement of the electrophysiological parameters, assessment of the left ventricular function and the clinical follow-up of patients.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Fascículo Atrioventricular/fisiología , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Electrocardiografía , Tabiques Cardíacos/fisiología , Humanos , Radiografía , Volumen Sistólico/fisiología , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/terapia
6.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 29(1): 3-11, jan.-mar.2016. graf
Artículo en Portugués | LILACS, SES-SP | ID: lil-788818

RESUMEN

Desde que foi iniciado, há 25 anos, o Registro Brasileiro de Marcapassos, Desfibriladores e Ressincronizadores Cardíacos (RBM) cadastrou 306.886 cirurgias até 31 de dezembro de 2014, das quais 216.537 foram primeiro implante (190.747 marcapassos, 13.725 cardiodesfibriladores, 6.683 ressincronizadores, 4.052 cardiodesfibriladores com ressincronizadores e 1.330 sem informações) e 90.349, trocas de dispositivos. Método: Analisamos o número de cirurgias e suas variedades entre 2000 e 2014 (dados de 31 de dezembro de 2015) e comparamos com alguns países, com a média europeia e com informações populacionais do Instituto Brasileiro de Geografia e Estatística. Resultados: O número do RBM referente às cirurgias realizadas no Brasil (129/1.000.000) foi comparado com a média europeia (960/1.000.000), verificando-se valores 7,4 vezes menores (mesmo estimando-se proporcionalmente, os valores são 4,5 vezes menores). A modificação na etiologia da primeira cirurgia entre 2009 e 2014 revelou aumento da incidência de fibrose do sistema de condução (de 32,58% para 38,05%) e redução da doença de Chagas (de 18% para 11,70%), sem grandes modificações nas outras causas. Considerando-se o número total de cirurgias, nota-se pequeno aumento em todas as regiões, exceto a Norte, com discreto aumento das cirurgias de cardiodesfibrilador implantável e cardiodesfibrilador implantável multissítio em todo o País. Houve pequeno aumento dos hospitais que realizaram cirurgias com a utilização desses dispositivos. O número total de médicos que fazem implantes de dispositivos aumentou discretamente, especialmente nas regiões Sul e Sudeste, com queda discreta nas outras. O grupo que realizou até 10 cirurgias por ano cresceu 19,28% e o de 11-50 cirurgias por ano, 12,84%...


Since it was started, 25 years ago, the Brazilian Registry of Pacemakers, CardioverterDefibrillators,and Cardiac Resynchronization Therapy Devices (RBM) registered 306,886 surgeries by December 31, 2014, 216,537 of which were: first implant (190,747 pacemakers, 13,725 cardioverter-defibrillators, 6,683 cardiac resynchronization therapy devices, 4,052 cardioverter-defibrillators with cardiac resynchronization therapy devices, and 1,330 with no information) in addition to 90,349 device replacements. Method: We analyzed the number of surgeries and their varieties, mostly between 2000 and 2014 (data of December 31, 2015)and compared with some countries, with the European average and with populational information from the Instituto Brasileiro de Geografia e Estatística. Results: We compared the RBM number of surgeries perfomed in Brazil (129/1,000,000) with the European average (960/1,000,000) and noticed values 7.4 times lower (even when estimated proportionally, results were 4.5 times lower). The change in the etiology of first surgery between 2009 and 2014 revealed an increase in the incidence of fibrosis of the conduction system (from 32.58% to 38.05%), and reduction of Chagas disease (from 18% to 11.70%) without any major changes in other causes. When taking into account the total number of surgeries, a small increase was observed in all regions, except for the North, with a discrete increase of implantable cardioverter-defibrillators and multisite implantable cardioverter-defibrillators surgeries across the country. There was a small increase in the number of hospitals that perform surgeries using these devices. The total number of doctors that perform device implantations has increased slightly, especially in the South and Southeast regions, with a slight decrease in the other regions. The group performing up to 10 surgeries per year increased 19.28%, and the one performing 11 to 50 surgeries per year increased 12.84%...


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Brasil , Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial , Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Enfermedad de Chagas/etiología , Enfermedad de Chagas/terapia , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia
7.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 27(2): 94-105, abr.-jun.2014.
Artículo en Portugués | LILACS | ID: lil-727489

RESUMEN

O implante de cardiodesfibriladores automáticos surgiu na década de 1980 como tratamentoalternativo na prevenção de arritmias graves em pacientes sobreviventes de fibrilação ventricular ou taquicardiaventricular sintomática. Os resultados iniciais mostraram resultados favoráveis à prevenção de morte súbita eredução de mortalidade geral com o uso desses dispositivos. Diante disso, a comprovação dessas evidências porestudos randomizados tornou-se de suma importância para indicação dessa prótese. A revisão dos resultadosdesses estudos demonstrou que o implante de cardiodesfibrilador automático éprimeira opção na terapêuticade pacientes com taquicardia ventricular sustentada ou fibrilação ventricular com comprometimentohemodinâmico, sendo também superior ao tratamento farmacológico em pacientes com taquicardia ventricularsustentada sintomática ou após ressuscitação de parada cardiorrespiratória. Nos casos de doença arterialcoronária, disfunção ventricular esquerda e presença de potenciais tardios ao eletrocardiograma, não háevidências em favor do implante desse dispositivo. O implante profilático de cardiodesfibrilador implantável empacientes de alto risco com infarto agudo do miocárdio recente não reduz a mortalidade geral. Esse dispositivonão representa benefícios para a sobrevivência nos casos de cardiomiopatia dilatada idiopática. A terapia comcardiodesfibrilador implantável combinada à terapia de ressincronização cardíaca melhora a qualidade devida, a classe funcional e a capacidade física na insuficiência cardíaca moderada a grave. Esse dispositivo estáassociado a redução equivalente da mortalidade em idosos e em indivíduos mais jovens, sem comprometimentoda qualidade de vida nos idosos, excluindo-se pacientes com comorbidades graves. O objetivo deste artigo érevisar os principais estudos clínicos em cardiodesfibrilador implantável, avaliando aspectos essenciais paraindicação dessa terapêutica.


The implantation of implantable cardioverter-defibrillators emerged in the 1980s as an alternativetreatment in the prevention of serious arrhythmias in survivors of ventricular fibrillation or symptomatic ventriculartachycardia. Initial results showed favorable for prevention of sudden death and overall mortality reduction withimplantable cardioverter-defibrillator results. Therefore, the evidence of such evidence by randomized trials hasbecome of paramount importance for implantable cardioverter-defibrillator indication. A review of the results of hese studies demonstrated that implantable cardioverter-defibrillator implantation is first choice in the treatmentof patients with sustained ventricular tachycardia or ventricular fibrillation with hemodynamic compromise,being also superior to medical therapy in patients with symptomatic sustained ventricular tachycardia or afterresuscitation from cardiac arrest. In cases of coronary artery disease, left ventricular dysfunction and presenceof late potentials on electrocardiogram, there is no evidence in favor of implantable cardioverter-defibrillatorimplantation. Prophylactic implantable cardioverter-defibrillator implantation in high-risk patients with recentacute myocardial infarction does not reduce overall mortality. The implantable cardioverter-defibrillator doesnot represent benefits for survival in cases of idiopathic dilated cardiomyopathy. Combination therapy withimplantable cardioverter-defibrillator and cardiac resynchronization therapy improves quality of life, functionalclass and exercise capacity in moderate to severe heart failure. The implantable cardioverter-defibrillator isassociated with an equivalent reduction of mortality in elderly and younger subjects without impairment ofquality of life in elderly patients, excluding patients with severe comorbidities.


Asunto(s)
Humanos , Adulto Joven , Anciano , Arritmias Cardíacas/complicaciones , Insuficiencia Cardíaca/diagnóstico , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Ensayo Clínico , Medicina Basada en la Evidencia , Estimulación Cardíaca Artificial/métodos
8.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 26(3): 151-161, jul.-set. 2013. tab
Artículo en Portugués | LILACS | ID: lil-716124

RESUMEN

A terapia de ressincronização cardíaca (TRC) surgiu como modalidade terapêutica para pacientes com insuficiência cardíaca (IC) refratária ao tratamento farmacológico. Ao longo dos últimos 15 anos, vários estudos clínicos buscaram estabelecer seus benefícios em diferentes populações. A revisão dos resultados desses estudos demonstrou que em pacientes com IC avançada (classe funcional III-IV da New York Heart Association - NYHA) a TRC produz melhorias consistentes para qualidade de vida, classe funcional e capacidade de exercício, além de reduzir as hospitalizações e a taxa de mortalidade. Esses efeitos benéficos são decorrentes do remodelamento reverso do ventrículo esquerdo, com melhoria da função ventricular. Em relação aos pacientes com IC leve a moderada (classe funcional I-II da NYHA), os resultados são controversos, embora a maioria dos estudos tenha demonstrado efeitos benéficos da TRC. Em pacientes com fibrilação atrial, existem poucos estudos bem delineados publicados, mas os resultados são favoráveis à TRC. Até 50% dos pacientes submetidos à TRC evoluem como não respondedores e a identificação destes pacientes é um desafio. Dessa maneira, várias questões ainda precisam ser elucidadas, particularmente os critérios preditivos da resposta à TRC e os benefícios da TRC nos pacientes com IC discreta, fibrilação atrial e outras arritmias. O objetivo deste artigo é revisar os principais estudos clínicos em TRC, abordando aspectos inerentes a essa modalidade terapêutica.


Asunto(s)
Humanos , Masculino , Femenino , Insuficiencia Cardíaca , Ensayos Clínicos Controlados Aleatorios como Asunto , Terapia de Resincronización Cardíaca/métodos , Quimioterapia , Ecocardiografía/métodos , Ejercicio Físico/fisiología , Función Ventricular/fisiología , Calidad de Vida
10.
Rev. Soc. Bras. Med. Trop ; 45(3): 340-345, May-June 2012. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-640432

RESUMEN

INTRODUCTION: The septal position is an alternative site for cardiac pacing (CP) that is potentially less harmful to cardiac function. METHODS: Patients with Chagas disease without heart failure submitted to permanent pacemaker (PP) implantation at the Clinics Hospital of the Triângulo Mineiro Federal University (UFTM), were selected from February 2009 to February 2010. The parameters analyzed were ventricular remodeling, the degree of electromechanical dyssynchrony (DEM), exercise time and VO2 max during exercise testing (ET) and functional class (NYHA). Echocardiography was performed 24 to 48h following implantation and after one year follow-up. The patients were submitted to ET one month postprocedure and at the end of one year. RESULTS: Thirty patients were included. Patient mean age was 59±13 years-old. Indication for PP implantation was complete atrioventricular (AV) block in 22 (73.3%) patients and 2nd degree AV block in the other eight (26.7%). All patients were in NYHA I and no changes occurred in the ET parameters. No variations were detected in echocardiographic remodeling measurements. Intraventricular dyssynchrony was observed in 46.6% of cases and interventricular dyssynchrony in 33.3% of patients after one year. CONCLUSIONS: The findings of this work suggest that there is not significant morphological and functional cardiac change following pacemaker implantation in septal position in chagasic patients with normal left ventricular function after one year follow-up. Thus, patients may remain asymptomatic, presenting maintenance of functional capacity and no left ventricular remodeling.


INTRODUÇÃO:A posição septal representa um sítio alternativo de estimulação cardíaca artificial (ECA) potencialmente menos deletério para a função cardíaca. M ÉTODOS: Pacientes chagásicos sem insuficiência cardíaca submetidos a implante de marcapasso definitivo (MP) no Hospital de Clínicas da Universidade Federal do Triângulo Mineiro (UFTM) foram selecionados no período de fevereiro de 2009 a fevereiro de 2010. Os parâmetros analisados foram o remodelamento ventricular, o grau de dessincronia eletromecânica (DEM), tempo de exercício e VO2 máximo no teste ergométrico (TE) e a classe funcional (NYHA). O ecocardiograma foi realizado 24 a 48h após o implante e após um ano de seguimento. Os pacientes foram submetidos ao TE um mês após o procedimento e ao final de um ano. RESULTADOS: Foram incluídos 30 pacientes. A idade média foi de 59±13 anos. A indicação do implante de MP foi bloqueio atrioventricular (BAV) total em 22 (73,3%) pacientes e BAV do 2º grau nos outros 8 (26,7%). Todos os pacientes permaneceram em NYHA I e não houve mudança nos parâmetros do TE. Não foram detectadas variações nas medidas ecocardiográficas de remodelamento. Foi observada DEM intraventricular em 46,6% dos casos e interventricular em 33,3% dos pacientes ao final de um ano. CONCLUSÕES: Os achados deste trabalho sugerem que não houve mudanças morfológicas ou funcionais cardíacas significativas após o implante de marcapasso na posição septal em pacientes chagásicos com função ventricular esquerda normal após um ano de seguimento. Desta forma, os pacientes podem permanecer assintomáticos, com a manutenção da capacidade funcional e sem remodelamento ventricular esquerdo.


Asunto(s)
Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Estimulación Cardíaca Artificial/métodos , Cardiomiopatía Chagásica/terapia , Marcapaso Artificial , Ecocardiografía , Electrocardiografía , Prueba de Esfuerzo , Estudios de Seguimiento , Resultado del Tratamiento , Tabique Interventricular
11.
Arq. bras. cardiol ; 96(1): 76-85, jan. 2011. ilus
Artículo en Portugués | LILACS | ID: lil-573608

RESUMEN

A estimulação ventricular direita convencional pode estar associada a efeitos deletérios sobre a função cardíaca. A necessidade de uma estimulação cardíaca artificial mais fisiológica é, indiscutivelmente, um dos pontos mais importantes na área da eletroterapia cardíaca. Os algoritmos de programação para a manutenção da condução atrioventricular própria, a estimulação de sítios endocárdicos alternativos e a terapia de ressincronização cardíaca são utilizados com o intuito de alcançar este objetivo. A estimulação do feixe de His e a estimulação septal têm sido estudadas como sítios endocárdicos alternativos para o posicionamento do eletrodo no ventrículo direito. A estimulação septal representa uma alternativa simples, prática e sem custos adicionais e com potenciais benefícios na redução dos efeitos deletérios da estimulação do ventrículo direito. Entretanto, esse sítio alternativo envolve um grupo heterogêneo de pacientes e apresenta resultados conflitantes quanto ao seu benefício clínico a longo prazo. Este artigo faz uma revisão das evidências científicas sobre os sítios alternativos de estimulação ventricular direita, com ênfase na segurança do procedimento, na medida dos parâmetros eletrofisiológicos, na avaliação da função ventricular esquerda e no acompanhamento clínico dos pacientes.


The conventional right ventricular stimulation can be associated with deleterious effects on cardiac function. The need for a more physiological artificial cardiac stimulation is undoubtedly one of the most important points in the area of cardiac electrotherapy. The programming algorithms for the maintenance of adequate atrioventricular conduction, the stimulation of alternative endocardial sites and the cardiac resynchronization therapy are used with the objective of attaining these goals. The stimulation of the bundle of His and the septal stimulation have been studied as alternative endocardial sites for the positioning of the electrode on the right ventricle. The septal stimulation represents a simple and practical alternative, with no additional costs involved and with potential benefits in decreasing the deleterious effects of the right ventricular stimulation. However, this alternative site involves a heterogeneous group of patients and presents conflicting results regarding its long-term clinical benefit. This article reviews the scientific evidence on the alternative sites for right ventricular stimulation, with emphasis on the safety of the procedure, the measurement of the electrophysiological parameters, assessment of the left ventricular function and the clinical follow-up of patients.


La estimulación ventricular derecha convencional puede estar asociada a efectos deletéreos sobre la función cardíaca. La necesidad de una estimulación cardíaca artificial más fisiológica es, indiscutiblemente, uno de los puntos más importantes en el área de la electroterapia cardíaca. Los algoritmos de programación para la manutención de la conducción atrioventricular propia, la estimulación de sitios endocárdicos alternativos y la terapia de resincronización cardíaca son utilizados con el propósito de alcanzar este objetivo. La estimulación del haz de His y la estimulación septal han sido estudiadas como sitios endocárdicos alternativos para el posicionamiento del electrodo en el ventrículo derecho. La estimulación septal representa una alternativa simple, práctica y sin costos adicionales y con potenciales beneficios en la reducción de los efectos deletéreos de la estimulación del ventrículo derecho. Entre tanto, ese sitio alternativo envuelve un grupo heterogéneo de pacientes y presenta resultados conflictivos en cuanto a su beneficio clínico a largo plazo. Este artículo hace una revisión de las evidencias científicas sobre los sitios alternativos de estimulación ventricular derecha, con énfasis en la seguridad del procedimiento, en la medida de los parámetros electrofisiológicos, en la evaluación de la función ventricular izquierda y en el control clínico de los pacientes.


Asunto(s)
Humanos , Terapia de Resincronización Cardíaca/métodos , Fascículo Atrioventricular/fisiología , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Electrocardiografía , Tabiques Cardíacos/fisiología , Volumen Sistólico/fisiología , Disfunción Ventricular Derecha , Disfunción Ventricular Derecha/terapia
12.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 24(4): 277-282, out.-dez. 2011. ilus
Artículo en Portugués | LILACS | ID: lil-610053

RESUMEN

A síndrome de Twiddler é uma complicação rara relacionada aos dispositivos eletrônicos cardíacos implantáveis (DCEI). É caracterizada pela rotação do gerador de pulsos dentro da bolsa subcutânea, o que resulta em deslocamento dos cabos-eletrodos endocárdicos e disfunção do sistema. Relata-se o caso de uma paciente que apresentou perda de comando e sensibilidade nos canais atrial e ventricular na avaliação telemétrica ambulatorial, cinco meses após o implante de cardiodesfibrilador automático implantável com ressincronizador (CDI-R). Na reabordagem cirúrgica foi observado o deslocamento dos três cabos-eletrodos e seu enrolamento em torno do gerador, configurando a síndrome de Twiddler. Os cabos-eletrodos foram reposicionados nas câmaras direitas e o gerador fixado ao plano muscular nas duas extremidades para evitar recorrência do processo.


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Bradicardia/complicaciones , Bradicardia/diagnóstico , Muerte Súbita , Taquicardia/complicaciones , Taquicardia/diagnóstico , Ecocardiografía/métodos , Ecocardiografía , Radiografía Torácica
13.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 24(4): 271-276, out.-dez. 2011. tab, ilus
Artículo en Portugués | LILACS | ID: lil-610052

RESUMEN

Com o advento da estimulação cardíaca artificial, surgiu a preocupação em expor seus princípios de maneira simples e prática. Em 1974, a Inter-Society Commission for Heart Disease Resources [ICHD] tomou essa iniciativa, ao desenvolver um código de três letras baseado no conceito sugerido por Nicholas P. D. Smyth, quatro anos antes. Ao longo dos anos, novos equipamentos cardio-estimuladores entraram no mercado, criando a necessidade de novas designações para as funções e os modos de operação, cada vez mais complexos. Em 1981, a revista PACE publicou a revisão do código ICHD, que passou a apresentar cinco letras. Outras nomenclaturas foram propostas pelo comitê composto por NASPE e BPEG, na tentativa de abranger dispositivos antibradicardia e antitaquicardia, por meio dos códigos NBG e NBD. Contradizendo todas as versões subsequentes ao código proposto por Nicholas Smyth, que objetivavam incluir o que de mais novo havia no assunto, foi proposta nova revisão do código NBG em 2002, que se mostra bastante simplificada e prática. Conclusão: A partir deste estudo, percebe-se que, independente das decisões dos fabricantes e do surgimento de novas tecnologias, o código de nomenclatura visa facilitar o entendimento das especificações dos dispositivos cardioestimuladores.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial
14.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 23(3): 122-125, jul.-set. 2010. ilus
Artículo en Portugués | LILACS | ID: lil-567757

RESUMEN

O implante de marcapasso com cabos-eletrodos endocavitários é a técnica preferida na atualidade. Entretanto, persiste o implante de cabo-eletrodo epiomiocárdico ou, simplesmente, epicárdico uma vez que nem todos os casos são elegíveis para o implante via endocavitária. Diferentes tipos de cabos-eletrodos estão disponíveis no mercado para implante de marcapassos epicárdicos definitivos e também temporários. Apesar de muito restrito, temos ainda o uso do cabo-eletrodo epicárdico na cardioversão-desfibrilação. Quanto à forma de fixação, eles são divididos em penetrantes e não penetrantes. Diversos acessos cirúrgicos podem ser adotados com o objetivo de expor o local no coração para realizar o implante desses cabos-eletrodos. O implante epicárdico deve ser abordado de forma individualizada para cada caso.


Asunto(s)
Electrodos , Marcapaso Artificial , Factores de Riesgo , Válvula Tricúspide/cirugía
16.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 22(3): 125-129, jul.-set. 2009.
Artículo en Portugués | LILACS | ID: lil-538320

RESUMEN

Em portadores de DCEI, as orientações sobre complicações associadas a procedimentos odontológicos em geral estão relacionadas ao tipo de anestésico utilizado e à adoção de medidas profiláticas contra a endocardite infecciosa. Anestésicos locais que contém vasoconstritores em sua fórmula possuem como principal vantagem a absorção lenta, o que reduz sua toxicidade e aumenta o efeito desejado. Além disso, vasoconstritores não adrenérgicos, que não provocam estimulação catecolaminérgica no sistema cardiovascular, não geram a maioria das complicações decorrentes da anestesia local em procedimentos odontológicos e que restringem seu uso em cardiopatas. Este artigo faz uma revisão do uso de anestésicos locais, com e sem vasoconstritores, em cardiopatas, bem como das recomendações e estudos sobre a profilaxia contra a endocardite infecciosa em procedimentos dentários.


Asunto(s)
Humanos , Endocarditis/complicaciones , Anestésicos Locales/farmacología
17.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 22(3): 136-142, jul.-set. 2009. ilus
Artículo en Portugués | LILACS | ID: lil-538322

RESUMEN

Em dispositivos cardíacos eletrônicos implantáveis (DCEI) de dupla-câmara, a frequência ventricular depende da atrial e taquiarritmias atriais podem ocasionar estimulações ventriculares rápidas e inapropriadas. O termo Automatic Mode Switching (AMS) define uma função automática que altera temporariamente o modo de estimulação dos DCEI durante episódios de taquiarritmia atrial, substituindo o modo deflagrado pelo átrio por outro em que não há deflagração por essa câmara. Após o término da arritmia, ocorre reversão espontânea ao modo de programação original, para manter o sincronismo atrioventricular. O grande desafio para o AMS é garantir que o mecanismo deflagre a mudança do modo de estimulação sempre que necessário e, ao mesmo tempo, evite atuações inapropriadas. Neste artigo é feita uma revisão da literatura sobre a importância do AMS e são analisados os algoritmos mais comuns.


Asunto(s)
Humanos , Taquicardia/complicaciones , Marcapaso Artificial
19.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 21(1): 39-47, jan.-mar. 2008. tab, graf, ilus
Artículo en Portugués | LILACS | ID: lil-489304

RESUMEN

Introdução: No implante de marcapasso endocárdico definitivo , a veia cefálica é a via de acesso preferencial. Entretanto, em um número significativo de pacientes, suas características não permitem a passagem dos cabos-eletrodos. Em marcapassos de dupla-câmara, a punção única da veia subclávia pode ser uma alternativa interessante, que garante acesso rápido ao ventrículo direito, principalmente nos pacientes chagásicos com alto grau de bloqueio AV e ritmos de escape com frequência muito baixa: Objetivo: Comparar as técnicas de punção única da subclávia e dissecção da veia cefálica quanto ao tempo operatório e ás complicações pós-operatórias em implantes de marcapasso de dupla-câmara. Casuística e Método: Estudo prospectivo que envolveu 200 pacientes (56 por cento) do sexo feminino e 88 (44 por cento) do sexo masculino, com sorologia positiva para doença de Chagas e indicações clássicas de implante de marcapasso por bradiarritmias. Em metade dos pacientes foi realizada a punção...


Introduction: in the definite endo-cardiac pacemaker implant, the cephalic vein is the preferable access route. However, in a significant number of patients, their characteristics don’t allow the passage of the electrode cables. In double-chamber pacemakers, the single puncture of the subclavian vein can be an interesting alternative, which guarantees quick access to the right ventricle, especially in chagasic patients with a high degree of AV blockage and very low frequency escape rhythms. Objective: compare the single puncture techniques of the subclavian vein and the dissection of the cephalic vein as to the surgical time and the post-op complications in double chamber pacemakers in chagasic patients. Casuistry andMethod: prospective study that involved 200 patients, 112 (56%) female and 88 (44%) male, which tested positive for the chagas disease and classic indications for pacemaker implanting for bradyarrhythmias. In halfof the patients, a single puncture of the subclavian vein was performed for the implantation of two electrode cables. The 100 other patients were submitted to a dissection of the cephalic vein and an additional subclavian puncture, when necessary. Results: surgical time averaged 16,11 minutes less in the single subclavian puncture. The cephalic vein did not allow the introduction of the two electrode cables in 50% of the dissection attempts. There was one hemothorax case and two pneumothorax cases in the group submitted to the single puncture (3%). The number of complications was low, not allowing for statistical comparisons between the two techniques analyzed. Conclusion: the subclavian single puncture techniques presented lesser surgical time and a low rate of complications, representing a viable alternative in chagasic patients.


Introducción: en el implante de marcapasos endocárdico definitivo, la vena cefálica es la vía de acceso preferente. Sin embargo, en un número significativo de pacientes, sus características no permiten el pasaje de los cables-electrodos. En marcapasos de doble cámara, la punción única de la vena subclavia puede ser una alternativa interesante, que asegura acceso rápido al ventrículo derecho, especialmente en los pacientes chagásicos con alto grado de bloqueo AV y ritmos de escape con frecuencia muy baja. Objetivo: comparar las técnicas de punción única de la subclavia y disección de la vena cefálica en cuanto al tiempo operatorio y las complicaciones postoperatorias en implantes de marcapasos de doble cámara en chagásicos. Casuística y Método: estudio prospectivo que involucró a 200 pacientes, 112 (56%) del sexo femenino y 88 (44%) del sexo masculino, con serología positiva para enfermedad de Chagas e indicaciones clásicas de implante de marcapasos por bradiarritmias. En la mitad de los pacientes se llevó a cabo la punción única de la vena subclavia para el implante de ambos cables-electrodos. Los otros 100 pacientes se sometieron a disección de la vena cefálica y punción adicional de la subclavia, cuando necesario. Resultados: el tiempo quirúrgico fue en promedio 16,11 minutos menor en la punción única de la subclavia. La vena cefálica no permitió la introducción de ambos cables-electrodos en el 50% de los intentos de disección. Hubo un caso de hemotórax y dos casos de neumotórax en el grupo sometido a punción única (3%). El número de complicaciones fue bajo, no permitiendo comparaciones estadísticas entre ambas técnicas analizadas. Conclusión: la técnica de punción única de la subclavia presentó menor tiempo operatorio y bajo índice de complicaciones, representando una alternativa viable en pacientes chagásicos.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Enfermedad de Chagas , Marcapaso Artificial , Estudio Comparativo , Radiografía
20.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 20(2): 79-89, abr.-jun.2007. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-469968

RESUMEN

Introdução: a dessincronização causada pela estimulação endocárdica nas regiões subtricuspídea e na ponta do ventrículo direito implica a necessidade de buscar alternativas para tornar a ativação ventricular mais fisiológica. A estimulação septal proporciona complexos QRS mais estreitos, o que pode tornar a estimulação cardíaca menos deletéria. Pacientes chagásicos...


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Cardiomiopatía Chagásica , Marcapaso Artificial , Estudios de Seguimiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA