Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Plant Physiol ; 195(3): 1925-1940, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38427921

RESUMEN

Leaf senescence is a vital aspect of plant physiology and stress responses and is induced by endogenous factors and environmental cues. The plant-specific NAC (NAM, ATAF1/2, CUC2) transcription factor family influences growth, development, and stress responses in Arabidopsis (Arabidopsis thaliana) and other species. However, the roles of NACs in tobacco (Nicotiana tabacum) leaf senescence are still unclear. Here, we report that NtNAC56 regulates leaf senescence in tobacco. Transgenic plants overexpressing NtNAC56 (NtNAC56-OE) showed induction of senescence-related genes and exhibited early senescence and lower chlorophyll content compared to wild-type (WT) plants and the Ntnac56-19 mutant. In addition, root development and seed germination were inhibited in the NtNAC56-OE lines. Transmission electron microscopy observations accompanied by physiological and biochemical assays revealed that NtNAC56 overexpression triggers chloroplast degradation and reactive oxygen species accumulation in tobacco leaves. Transcriptome analysis demonstrated that NtNAC56 activates leaf senescence-related genes and jasmonic acid (JA) biosynthesis pathway genes. In addition, the JA content of NtNAC56-OE plants was higher than in WT plants, and JA treatment induced NtNAC56 expression. We performed DNA affinity purification sequencing to identify direct targets of NtNAC56, among which we focused on LIPOXYGENASE 5 (NtLOX5), a key gene in JA biosynthesis. A dual-luciferase reporter assay and a yeast one-hybrid assay confirmed that NtNAC56 directly binds to the TTTCTT motif in the NtLOX5 promoter. Our results reveal a mechanism whereby NtNAC56 regulates JA-induced leaf senescence in tobacco and provide a strategy for genetically manipulating leaf senescence and plant growth.


Asunto(s)
Ciclopentanos , Regulación de la Expresión Génica de las Plantas , Nicotiana , Oxilipinas , Hojas de la Planta , Proteínas de Plantas , Senescencia de la Planta , Plantas Modificadas Genéticamente , Factores de Transcripción , Nicotiana/genética , Nicotiana/fisiología , Nicotiana/efectos de los fármacos , Nicotiana/crecimiento & desarrollo , Oxilipinas/metabolismo , Oxilipinas/farmacología , Ciclopentanos/metabolismo , Ciclopentanos/farmacología , Hojas de la Planta/metabolismo , Hojas de la Planta/genética , Hojas de la Planta/fisiología , Senescencia de la Planta/genética , Factores de Transcripción/metabolismo , Factores de Transcripción/genética , Proteínas de Plantas/metabolismo , Proteínas de Plantas/genética , Especies Reactivas de Oxígeno/metabolismo , Clorofila/metabolismo , Cloroplastos/metabolismo , Cloroplastos/ultraestructura , Regiones Promotoras Genéticas/genética
2.
Plant Biotechnol J ; 22(7): 1897-1912, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38386569

RESUMEN

Silique number is a crucial yield-related trait for the genetic enhancement of rapeseed (Brassica napus L.). The intricate molecular process governing the regulation of silique number involves various factors. Despite advancements in understanding the mechanisms regulating silique number in Arabidopsis (Arabidopsis thaliana) and rice (Oryza sativa), the molecular processes involved in controlling silique number in rapeseed remain largely unexplored. In this review, we identify candidate genes and review the roles of genes and environmental factors in regulating rapeseed silique number. We use genetic regulatory networks for silique number in Arabidopsis and grain number in rice to uncover possible regulatory pathways and molecular mechanisms involved in regulating genes associated with rapeseed silique number. A better understanding of the genetic network regulating silique number in rapeseed will provide a theoretical basis for the genetic improvement of this trait and genetic resources for the molecular breeding of high-yielding rapeseed.


Asunto(s)
Brassica napus , Brassica napus/genética , Brassica napus/crecimiento & desarrollo , Semillas/genética , Semillas/crecimiento & desarrollo , Regulación de la Expresión Génica de las Plantas , Redes Reguladoras de Genes , Oryza/genética , Oryza/crecimiento & desarrollo , Fitomejoramiento/métodos , Arabidopsis/genética , Arabidopsis/crecimiento & desarrollo
3.
J Appl Clin Med Phys ; 24(4): e13918, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36729373

RESUMEN

PURPOSE: Ethos CBCT-based adaptive radiotherapy (ART) system can generate an online adaptive plan by re-optimizing the initial reference plan based on the patient anatomy at the treatment. The optimization process is fully automated without any room for human intervention. Due to the change in anatomy, the ART plan can be significantly different from the initial plan in terms of plan parameters such as the aperture shapes and number of monitor units (MUs). In this study, we investigated the feasibility of using calculation-based patient specific QA for ART plans in conjunction with measurement-based and calculation-based QA for initial plans to establish an action level for the online ART patient-specific QA. METHODS: A cohort of 98 cases treated on CBCT-based ART system were collected for this study. We performed measurement-based QA using ArcCheck and calculation-based QA using Mobius for both the initial plan and the ART plan for analysis. For online the ART plan, Mobius calculation was conducted prior to the delivery, while ArcCheck measurement was delivered on the same day after the treatment. We first investigated the modulation factors (MFs) and MU numbers of the initial plans and ART plans, respectively. The γ passing rates of initial and ART plan QA were analyzed. Then action limits were derived for QA calculation and measurement for both initial and online ART plans, respectively, from 30 randomly selected patient cases, and were evaluated using the other 68 patient cases. RESULTS: The difference in MF between initial plan and ART-plan was 12.9% ± 12.7% which demonstrates their significant difference in plan parameters. Based on the patient QA results, pre-treatment calculation and measurement results are generally well aligned with ArcCheck measurement results for online ART plans, illustrating their feasibility as an indicator of failure in online ART QA measurements. Furthermore, using 30 randomly selected patient cases, the γ analysis action limit derived for initial plans and ART plans are 89.6% and 90.4% in ArcCheck QA (2%/2 mm) and are 92.4% and 93.6% in Mobius QA(3%/2 mm), respectively. According to the calculated action limits, the ArcCheck measurements for all the initial and ART plans passed QA successfully while the Mobius calculation action limits flagged seven and four failure cases respectively for initial plans and ART plans, respectively. CONCLUSION: An ART plan can be substantially different from the initial plan, and therefore a separate session of ART plan QA is needed to ensure treatment safety and quality. The pre-treatment QA calculation via Mobius can serve as a reliable indicator of failure in online ART plan QA. However, given that Ethos ART system is still relatively new, ArcCheck measurement of initial plan is still in practice. It may be skipped as we gain more experience and have better understanding of the system.


Asunto(s)
Radioterapia de Intensidad Modulada , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Garantía de la Calidad de Atención de Salud , Dosificación Radioterapéutica
4.
J Appl Clin Med Phys ; 24(7): e13950, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36877668

RESUMEN

PURPOSE: Varian Ethos utilizes novel intelligent-optimization-engine (IOE) designed to automate the planning. However, this introduced a black box approach to plan optimization and challenge for planners to improve plan quality. This study aims to evaluate machine-learning-guided initial reference plan generation approaches for head & neck (H&N) adaptive radiotherapy (ART). METHODS: Twenty previously treated patients treated on C-arm/Ring-mounted were retroactively re-planned in the Ethos planning system using a fixed 18-beam intensity-modulated radiotherapy (IMRT) template. Clinical goals for IOE input were generated using (1) in-house deep-learning 3D-dose predictor (AI-Guided) (2) commercial knowledge-based planning (KBP) model with universal RTOG-based population criteria (KBP-RTOG) and (3) an RTOG-based constraint template only (RTOG) for in-depth analysis of IOE sensitivity. Similar training data was utilized for both models. Plans were optimized until their respective criteria were achieved or DVH-estimation band was satisfied. Plans were normalized such that the highest PTV dose level received 95% coverage. Target coverage, high-impact organs-at-risk (OAR) and plan deliverability was assessed in comparison to clinical (benchmark) plans. Statistical significance was evaluated using a paired two-tailed student t-test. RESULTS: AI-guided plans were superior to both KBP-RTOG and RTOG-only plans with respect to clinical benchmark cases. Overall, OAR doses were comparable or improved with AI-guided plans versus benchmark, while they increased with KBP-RTOG and RTOG plans. However, all plans generally satisfied the RTOG criteria. Heterogeneity Index (HI) was on average <1.07 for all plans. Average modulation factor was 12.2 ± 1.9 (p = n.s), 13.1 ± 1.4 (p = <0.001), 11.5 ± 1.3 (p = n.s.) and 12.2 ± 1.9 for KBP-RTOG, AI-Guided, RTOG and benchmark plans, respectively. CONCLUSION: AI-guided plans were the highest quality. Both KBP-enabled and RTOG-only plans are feasible approaches as clinics adopt ART workflows. Similar to constrained optimization, the IOE is sensitive to clinical input goals and we recommend comparable input to an institution's planning directive dosimetric criteria.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Cuello , Órganos en Riesgo , Radioterapia de Intensidad Modulada/métodos , Aprendizaje Automático
5.
Plants (Basel) ; 13(12)2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38931141

RESUMEN

Cyclin B (CYCB) is a regulatory subunit of cyclin-dependent kinase (CDK), the concentration of which fluctuates to regulate cell cycle progression. Extensive studies have been performed on cyclins in numerous species, yet the evolutionary relationships and biological functions of the CYCB family genes in Brassica napus remain unclear. In this study, we identified 299 CYCB genes in 11 B. napus accessions. Phylogenetic analysis suggests that CYCB genes could be divided into three subfamilies in angiosperms and that the CYCB3 subfamily members may be a newer group that evolved in eudicots. The expansion of BnaCYCB genes underwent segmental duplication and purifying selection in genomes, and a number of drought-responsive and light-responsive cis-elements were found in their promoter regions. Additionally, expression analysis revealed that BnaCYCBs were strongly expressed in the developing seed and silique pericarp, as confirmed by the obviously reduced seed size of the mutant cycb3;1 in Arabidopsis thaliana compared with Col-0. This study provides a comprehensive evolutionary analysis of CYCB genes as well as insight into the biological function of CYCB genes in B. napus.

6.
Radiother Oncol ; 197: 110178, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38453056

RESUMEN

OBJECTIVE: We explore the potential dosimetric benefits of reducing treatment volumes through daily adaptive radiation therapy for head and neck cancer (HNC) patients using the Ethos system/Intelligent Optimizer Engine (IOE). We hypothesize reducing treatment volumes afforded by daily adaption will significantly reduce the dose to adjacent organs at risk. We also explore the capability of the Ethos IOE to accommodate this highly conformal approach in HNC radiation therapy. METHODS: Ten HNC patients from a phase II trial were chosen, and their cone-beam CT (CBCT) scans were uploaded to the adaptive RT (ART) emulator. A new initial reference plan was generated using both a 1 mm and 5 mm planning target volume (PTV) expansion. Daily adaptive ART plans (1 mm) were simulated from the clinical CBCT taken every fifth fraction. Additionally, using physician-modified ART contours the larger 5 mm plan was recalculated on this recontoured on daily anatomy. Changes in target and OAR contours were measured using Dice coefficients as a surrogate of clinician effort. PTV coverage and organ-at-risk (OAR) doses were statistically compared, and the robustness of each ART plan was evaluated at fractions 5 and 35 to observe if OAR doses were within 3 Gy of pre-plan. RESULTS: This study involved six patients with oropharynx and four with larynx cancer, totaling 70 adaptive fractions. The primary and nodal gross tumor volumes (GTV) required the most adjustments, with median Dice scores of 0.88 (range: 0.80-0.93) and 0.83 (range: 0.66-0.91), respectively. For the 5th and 35th fraction plans, 80 % of structures met robustness criteria (quartile 1-3: 67-100 % and 70-90 %). Adaptive planning improved median PTV V100% coverage for doses of 70 Gy (96 % vs. 95.6 %), 66.5 Gy (98.5 % vs. 76.5 %), and 63 Gy (98.9 % vs. 74.9 %) (p < 0.03). Implementing ART with total volume reduction yielded median dose reductions of 7-12 Gy to key organs-at-risk (OARs) like submandibular glands, parotids, oral cavity, and constrictors (p < 0.05). CONCLUSIONS: The IOE enables feasible daily ART treatments with reduced margins while enhancing target coverage and reducing OAR doses for HNC patients. A phase II trial recently finished accrual and forthcoming analysis will determine if these dosimetric improvements correlate with improved patient-reported outcomes.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Estudios de Factibilidad , Neoplasias de Cabeza y Cuello , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Simulación por Computador
7.
Adv Radiat Oncol ; 8(5): 101256, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37408672

RESUMEN

Purpose: The advent of cone beam computed tomography-based online adaptive radiation therapy (oART) has dramatically reduced the barriers of adaptation. We present the first prospective oART experience data in radiation of head and neck cancers (HNC). Methods and Materials: Patients with HNC receiving definitive standard fractionation (chemo)radiation who underwent at least 1 oART session were enrolled in a prospective registry study. The frequency of adaptations was at the discretion of the treating physician. Physicians were given the option of delivering 1 of 2 plans during adaptation: the original radiation plan transposed onto the cone beam computed tomography with adapted contours (scheduled), and a new adapted plan generated from the updated contours (adapted). A paired t test was used to compare the mean doses between scheduled and adapted plans. Results: Twenty-one patients (15 oropharynx, 4 larynx/hypopharynx, 2 other) underwent 43 adaptation sessions (median, 2). The median ART process time was 23 minutes, median physician time at the console was 27 minutes, and median patient time in the vault was 43.5 minutes. The adapted plan was chosen 93% of the time. The mean volume in each planned target volume (PTV) receiving 100% of the prescription dose for the scheduled versus adapted plan for high-risk PTVs was 87.8% versus 95% (P < .01), intermediate-risk PTVs was 87.3% versus 97.9% (P < .01), and low-risk PTVs was 94% versus 97.8% (P < .01), respectively. The mean hotspot was also lower with adaptation: 108.8% versus 106.4% (P < .01). All but 1 organ at risk (11/12) saw a decrease in their dose with the adapted plans, with the mean ipsilateral parotid (P = .013), mean larynx (P < .01), maximum point spinal cord (P < .01), and maximum point brain stem (P = .035) reaching statistical significance. Conclusions: Online ART is feasible for HNC, with significant improvement in target coverage and homogeneity and a modest decrease in doses to several organs at risk.

8.
Med Phys ; 50(12): 7368-7382, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37358195

RESUMEN

BACKGROUND: MRI-only radiotherapy planning (MROP) is beneficial to patients by avoiding MRI/CT registration errors, simplifying the radiation treatment simulation workflow and reducing exposure to ionizing radiation. MRI is the primary imaging modality for soft tissue delineation. Treatment planning CTs (i.e., CT simulation scan) are redundant if a synthetic CT (sCT) can be generated from the MRI to provide the patient positioning and electron density information. Unsupervised deep learning (DL) models like CycleGAN are widely used in MR-to-sCT conversion, when paired patient CT and MR image datasets are not available for model training. However, compared to supervised DL models, they cannot guarantee anatomic consistency, especially around bone. PURPOSE: The purpose of this work was to improve the sCT accuracy generated from MRI around bone for MROP. METHODS: To generate more reliable bony structures on sCT images, we proposed to add bony structure constraints in the unsupervised CycleGAN model's loss function and leverage Dixon constructed fat and in-phase (IP) MR images. Dixon images provide better bone contrast than T2-weighted images as inputs to a modified multi-channel CycleGAN. A private dataset with a total of 31 prostate cancer patients were used for training (20) and testing (11). RESULTS: We compared model performance with and without bony structure constraints using single- and multi-channel inputs. Among all the models, multi-channel CycleGAN with bony structure constraints had the lowest mean absolute error, both inside the bone and whole body (50.7 and 145.2 HU). This approach also resulted in the highest Dice similarity coefficient (0.88) of all bony structures compared with the planning CT. CONCLUSION: Modified multi-channel CycleGAN with bony structure constraints, taking Dixon-constructed fat and IP images as inputs, can generate clinically suitable sCT images in both bone and soft tissue. The generated sCT images have the potential to be used for accurate dose calculation and patient positioning in MROP radiation therapy.


Asunto(s)
Radioterapia de Intensidad Modulada , Masculino , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Pelvis , Procesamiento de Imagen Asistido por Computador/métodos
9.
Mol Imaging Biol ; 24(1): 23-30, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34286423

RESUMEN

PURPOSE: The ability to noninvasively quantify receptor availability (RA) in solid tumors is an aspirational goal of molecular imaging, often challenged by the influence of non-specific accumulation of the contrast agent. Paired-agent imaging (PAI) techniques aim to compensate for this effect by imaging the kinetics of a targeted agent and an untargeted isotype, often simultaneously, and comparing the kinetics of the two agents to estimate RA. This is usually accomplished using two spectrally distinct fluorescent agents, limiting the technique to superficial tissues and/or preclinical applications. Applying the approach in humans using conventional imaging modalities is generally infeasible since most modalities are unable to routinely image multiple agents simultaneously. We examine the ability of PAI to be implemented in a cross-modality paradigm, in which the targeted and untargeted agent kinetics are imaged with different modalities and used to recover receptor availability. PROCEDURES: Eighteen mice bearing orthotopic brain tumors were administered a solution containing three contrast agents: (1) a fluorescent agent targeted to epidermal growth factor receptor (EGFR), (2) an untargeted fluorescent isotype, and (3) a gadolinium-based contrast agent (GBCA) for MRI imaging. The kinetics of all three agents were imaged for 1 h after administration using an MRI-coupled fluorescence tomography system. Paired-agent receptor availability was computed using (1) the conventional all-optical approach using the targeted and untargeted optical agent images and (2) the cross-modality approach using the targeted optical and untargeted MRI-GBCA images. Receptor availability estimates between the two methods were compared. RESULTS: Receptor availability values using the cross-modality approach were highly correlated to the conventional, single-modality approach (r = 0.94; p < 0.00001). CONCLUSION: These results suggest that cross-modality paired-agent imaging for quantifying receptor availability is feasible. Ultimately, cross-modality paired-agent imaging could facilitate rapid, noninvasive receptor availability quantification in humans using hybrid clinical imaging modalities.


Asunto(s)
Neoplasias Encefálicas , Animales , Medios de Contraste , Estudios de Factibilidad , Imagen por Resonancia Magnética , Ratones , Imagen Molecular/métodos
10.
Front Oncol ; 12: 898822, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36046047

RESUMEN

Adaptive radiotherapy has the potential to reduce margins, improve target coverage, and decrease toxicity to organs at risk (OARs) by optimizing radiation delivery to daily anatomic changes. Salvage for locally recurrent prostate cancer after definitive radiation remains a challenging clinical scenario given the risks to normal tissue in a setting of re-irradiation. Here, we present a case series of five patients with locally recurrent prostate cancer treated with an adaptive online linear accelerator or a 3-T MR-based linear accelerator to demonstrate excellent target coverage. All patients completed the planned treatment course with acceptable acute toxicities but a short follow-up time does not inform subacute/late toxicities.

11.
Artículo en Inglés | MEDLINE | ID: mdl-34446980

RESUMEN

Concurrent administration of cancer therapeutics with tumor vasculature targeting treatment has been shown to improve overall survival in multiple human cancer types, as such combinations aim to destroy different compartments of tumors. Anti-angiogenesis therapeutics designed to inhibit tumor induced vessel sprouting have also been shown to re-model the tumor vasculature through a transient vessel normalization effect, which leads to improved perfusion of oxygen and drug in tumor. However, the effects that this normalized vasculature has on the availability of cancer receptor, such as EGFR, is unknown. Herein, we examined the use of MRI-PAFT to estimate cancer surface receptor availability in response to anti-angiogenesis therapy, using MRI-coupled paired agent fluorescence tomography. Bevacizumab treated tumors showed increase in RA compared to control tumors, but this was not statistically significant.

12.
Biomed Opt Express ; 12(1): 395-408, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33520389

RESUMEN

Whole-animal fluorescence cryo-imaging is an established technique that enables visualization of the biodistribution of labeled drugs, contrast agents, functional reporters and cells in detail. However, many tissues produce endogenous autofluorescence, which can confound interpretation of the cryo-imaging volumes. We describe a multi-channel, hyperspectral cryo-imaging system that acquires densely-sampled spectra at each pixel in the 3-dimensional stack. This information enables the use of spectral unmixing to isolate the fluorophore-of-interest from autofluorescence and/or other fluorescent reporters. In phantoms and a glioma xenograft model, we show that the approach improves detection limits, increases tumor contrast, and can dramatically alter image interpretation.

13.
Artículo en Inglés | MEDLINE | ID: mdl-34446978

RESUMEN

Angiogenesis inhibiting cancer therapy has become a standard treatment for many cancer types. The ability to examine the effects of these drugs in tumors noninvasively could help assess efficacy early in the treatment course or identify optimal times to introduce other combinatorial treatments. Herein, we examine whether a paired agent MRI-coupled fluorescence tomography approach can be used to monitor the effects of anti-angiogenesis therapy. Using small animal models bearing orthotopic glioma xenografts, we demonstrate noninvasive quantification of paired-agent uptake in response to anti-angiogenesis therapy in vivo. The result provides insights on receptor targeted drug delivery in altered vasculature, a potential important development for treatment monitoring and combinatorial strategies.

14.
Artículo en Inglés | MEDLINE | ID: mdl-34446979

RESUMEN

The ability to directly measure whole-body fluorescence can enable tracking of labeled cells, metastatic spread, and drug bio-distribution. We describe the development of a new hyperspectral imaging whole body cryo-macrotome designed to acquire 3-D fluorescence volumes in large specimens (whole animals) at high resolution. The use of hyperspectral acquisition provides full spectra at every voxel, enabling spectral decoupling of multiple fluorohpores and autofluorescence. We present examples of tissue spectra and spectral fitting in a rodent glioma xenograft.

15.
Artículo en Inglés | MEDLINE | ID: mdl-34707326

RESUMEN

Optical tomography is often coupled with high resolution imaging modality like MRI to provide functional information associated with specific anatomical structure noninvasively. MRI-coupled paired agent fluorescence molecular tomography (MRI-PAFT) is a hybrid imaging modality capable of noninvasively quantifying drug-target engagement in vivo utilizing a targeted and an untargeted fluorescence agent. This study compares the uptake kinetics of MRI contrast agent and fluorescence agents in tumor and normal tissue, and demonstrates the potential of utilizing MRI contrast agent kinetic and targeted fluorescence agent kinetics to quantify targeted tumor receptor concentration in glioma tumor model.

16.
Theranostics ; 10(24): 11230-11243, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33042280

RESUMEN

Immuno-oncological treatment strategies that target abnormal receptor profiles of tumors are an increasingly important feature of cancer therapy. Yet, assessing receptor availability (RA) and drug-target engagement, important determinants of therapeutic efficacy, is challenging with current imaging strategies, largely due to the complex nonspecific uptake behavior of imaging agents in tumors. Herein, we evaluate whether a quantitative noninvasive imaging approach designed to compensate for nonspecific uptake, MRI-coupled paired-agent fluorescence tomography (MRI-PAFT), is capable of rapidly assessing the availability of epidermal growth factor receptor (EGFR) in response to one dose of anti-EGFR antibody therapy in orthotopic brain tumor models. Methods: Mice bearing orthotopic brain tumor xenografts with relatively high EGFR expression (U251) (N=10) or undetectable human EGFR (9L) (N=9) were considered in this study. For each tumor type, mice were either treated with one dose of cetuximab, or remained untreated. All animals were scanned using MRI-PAFT, which commenced immediately after paired-agent administration, and values of RA were recovered using a model-based approach, which uses the entire dynamic sequence of agent uptake, as well as a simplified "snapshot" approach which requires uptake measurements at only two time points. Recovered values of RA were evaluated between groups and techniques. Hematoxylin & eosin (H&E) and immunohistochemical (IHC) staining was performed on tumor specimens from every animal to confirm tumor presence and EGFR status. Results: In animals bearing EGFR(+) tumors, a significant difference in RA values between treated and untreated animals was observed (RA = 0.24 ± 0.15 and 0.61 ± 0.18, respectively, p=0.027), with an area under the curve - receiver operating characteristic (AUC-ROC) value of 0.92. We did not observe a statistically significant difference in RA values between treated and untreated animals bearing EGFR(-) tumors (RA = 0.18 ± 0.19 and 0.27 ± 0.21, respectively; p = 0.89; AUC-ROC = 0.55), nor did we observe a difference between treated EGFR(+) tumors compared to treated and untreated EGFR(-) tumors. Notably, the snapshot paired-agent strategy quantified drug-receptor engagement within just 30 minutes of agent administration. Examination of the targeted agent alone showed no capacity to distinguish tumors either by treatment or receptor status, even 24h after agent administration. Conclusions: This study demonstrated that a noninvasive imaging strategy enables rapid quantification of receptor availability in response to therapy, a capability that could be leveraged in preclinical drug development, patient stratification, and treatment monitoring.


Asunto(s)
Neoplasias Encefálicas/tratamiento farmacológico , Cetuximab/uso terapéutico , Imagen Óptica/métodos , Proteínas Recombinantes de Fusión/administración & dosificación , Animales , Bencenosulfonatos/química , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Línea Celular Tumoral , Cetuximab/farmacología , Receptores ErbB/análisis , Receptores ErbB/antagonistas & inhibidores , Receptores ErbB/metabolismo , Fluorescencia , Humanos , Indoles/química , Imagen por Resonancia Magnética , Ratones , Imagen Molecular/métodos , Proteínas Recombinantes de Fusión/química , Ensayos Antitumor por Modelo de Xenoinjerto
17.
Artículo en Inglés | MEDLINE | ID: mdl-34183872

RESUMEN

A paired-agent fluorescent molecular imaging strategy is presented as a method to measure drug target engagement in whole tumor imaging. The protocol involves dynamic imaging of a pair of targeted and control imaging agents prior to and following antibody therapy. Simulations demonstrated that antibody "drug target engagement" can be estimated within a 15%-error over a wide range of tumor physiology (blood flow, vascular permeability, target density) and antibody characteristics (affinity, binding rates). Experimental results demonstrated the first in vivo detection of binding site barrier, highlighting the potential for this methodology to provide novel insights in drug distribution/binding imaging.

18.
PLoS One ; 15(3): e0230267, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32160634

RESUMEN

PURPOSE: Rapid, intra-operative identification of tumor tissue in the margins of excised specimens has become an important focus in the pursuit of reducing re-excision rates, especially for breast conserving surgery. Dual-probe difference specimen imaging (DDSI) is an emerging approach that uses the difference in uptake/clearance kinetics between a pair of fluorescently-labeled stains, one targeted to a biomarker-of-interest and the other an untargeted isotype, to reveal receptor-specific images of the specimen. Previous studies using antibodies labeled with either enhanced Raman particles or organic fluorophores have shown promising tumor vs. normal diagnostic performance. Yet, the unique properties of quantum dot-labeled antibody complexes (QDACs), which provide spectrally-distinct fluorescence emission from a common excitation source, make them ideal candidates for this application. Herein, we evaluate the diagnostic performance of QDAC-based DDSI in excised xenografts. PROCEDURES: Excised fresh specimens of normal tissue and human tumor xenografts with elevated expression of HER2 were stained with a HER2-targeted QDAC and an untargeted QDAC isotype. Stained specimens were imaged on a custom hyperspectral imaging system capable of spectrally separating the quantum dot signatures, and images processed using the DDSI approach. The diagnostic performance of this technique under different incubation temperatures and probe concentrations was evaluated using receiver-operator characteristic analysis. RESULTS: HER2-targeted QDAC-DDSI was able to distinguish HER2(+) tumors from normal tissue with reasonably high diagnostic performance; however, this performance was sensitive to temperature during the staining procedure. Area under the curve values were 0.61 when staining at room temperature but increased to over 0.81 when staining at 37 °C. Diagnostic performance was not affected by increasing stain concentration. CONCLUSIONS: This study is the first to report dual-probe difference imaging of specimens using QDACs and hyperspectral imaging. Our results show promising diagnostic performance under certain conditions, and compel further optimization and evaluation of this intra-operative margin assessment technique.


Asunto(s)
Biomarcadores de Tumor/inmunología , Neoplasias Mamarias Experimentales/diagnóstico , Puntos Cuánticos , Animales , Anticuerpos/inmunología , Femenino , Humanos , Inmunoensayo/métodos , Inmunoensayo/normas , Células MCF-7 , Ratones , Ratones Desnudos , Microscopía Fluorescente/métodos , Microscopía Fluorescente/normas , Receptor ErbB-2/inmunología
19.
Phys Med Biol ; 65(9): 095004, 2020 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-32135522

RESUMEN

This study demonstrates remote imaging for in vivo detection of radiation-induced tumor microstructural changes by tracking the diffusive spread of injected intratumor UV excited tattoo ink using Cherenkov-excited luminescence imaging (CELI). Micro-liter quantities of luminescent tattoo ink with UV absorption and visible emission were injected at a depth of 2 mm into mouse tumors prior to receiving a high dose treatment of radiation. X-rays from a clinical linear accelerator were used to excite phosphorescent compounds within the tattoo ink through Cherenkov emission. The in vivo phosphorescence was detected using a time-gated intensified CMOS camera immediately after injection, and then again at varying time points after the ink had broken down with the apoptotic tumor cells. Ex vivo tumors were imaged post-mortem using hyperspectral cryo-fluorescence imaging to quantify necrosis and compared to Cherenkov-excited light imaging of diffusive ink spread measured in vivo. Imaging of untreated control mice showed that ink distributions remained constant after four days with less than 3% diffusive spread measured using full width at 20% max. For all mice, in vivo CELI measurements matched within 12% of the values estimated by the high-resolution ex vivo sliced luminescence imaging of the tumors. The tattoo ink spread in treated mice was found to correlate well with the nonperfusion necrotic core volume (R2 = 0.92) but not well with total tumor volume changes (R2 = 0.34). In vivo and ex vivo findings indicate that the diffusive spread of the injected tattoo ink can be related to radiation-induced necrosis, independent of total tumor volume change. Tracking the diffusive spread of the ink allows for distinguishing between an increase in tumor size due to new cellular growth and an increase in tumor size due to edema. Furthermore, the imaging resolution of CELI allows for in vivo tracking of subtle microenvironmental changes which occur earlier than tumor shrinkage and this offers the potential for novel, minimally invasive radiotherapy response assay without interrupting a singular clinical workflow.


Asunto(s)
Neoplasias de Cabeza y Cuello/patología , Neoplasias de Cabeza y Cuello/radioterapia , Procesamiento de Imagen Asistido por Computador/métodos , Tinta , Luminiscencia , Fantasmas de Imagen , Animales , Proliferación Celular , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Ratones , Ratones Desnudos , Células Tumorales Cultivadas , Rayos X , Ensayos Antitumor por Modelo de Xenoinjerto
20.
J Pharm Pharmacol ; 61(3): 347-52, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19222907

RESUMEN

OBJECTIVES: The purpose of this research was to evaluate the ability of adrenaline (epinephrine) to stimulate the uptake of ginsenoside Rg1 (Rg1) by Caco-2 cells. METHODS: Rg1 uptake was measured using Caco-2 cell monolayers. The Rg1 uptake medium with adrenaline at different concentrations was added to each well and incubated for different time intervals. Adrenergic antagonists such as phentolamine and propranolol were added to the incubation medium to investigate their effects on Rg1 uptake. The Rg1 concentration in the monolayers was determined by high-performance liquid chromatography. Transport of Rg1 across Caco-2 cells was also studied and an oral bioavailability study of Rg1 was carried out in rats. KEY FINDINGS: The incubation medium with adrenaline remarkably increased the amount of Rg1 uptake by Caco-2 cells. Adrenaline-induced Rg1 transport increased in a dose- and time-dependent manner. The effect of adrenergic antagonists on adrenaline-induced uptake of Rg1 was investigated and it was found that the enhancement effect was attenuated by the co-treatment with propranolol but not phentolamine. The transport amount of Rg1 by Caco-2 cells increased in response to 1 mM adrenaline, isoproterenol or salbutamol. In contrast, 1 mM phenylephrine had no effect on Rg1 transport in Caco-2 cells. The effect of adrenaline on the absorption of Rg1 was further investigated in vivo in rats. The co-administration with adrenaline in rats showed that the oral bioavailability was increased remarkably relative to the aqueous solution. The area under the plasma concentration-time curve of Rg1 after co-administration with 1 mM adrenaline was 79.1 +/- 31.04 microg/ml/h compared with 2.81 +/- 1.13 microg/ml/h for its aqueous solution. CONCLUSIONS: Adrenaline is effective for the stimulation of intestinal absorption of Rg1 and the enhanced absorption is mediated mainly by the interaction of adrenaline with beta2-adrenoceptors.


Asunto(s)
Agonistas de Receptores Adrenérgicos beta 2 , Fármacos del Sistema Nervioso Central/farmacocinética , Epinefrina/farmacología , Ginsenósidos/farmacocinética , Administración Oral , Agonistas Adrenérgicos/administración & dosificación , Agonistas Adrenérgicos/farmacología , Antagonistas Adrenérgicos/farmacología , Animales , Área Bajo la Curva , Disponibilidad Biológica , Transporte Biológico , Células CACO-2 , Cromatografía Líquida de Alta Presión , Relación Dosis-Respuesta a Droga , Epinefrina/administración & dosificación , Humanos , Ratas , Ratas Sprague-Dawley , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA