1.
Circulation ; 148(18): 1354-1367, 2023 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-37638389

RESUMEN

BACKGROUND: The circuit boundaries for reentrant ventricular tachycardia (VT) have been historically conceptualized within a 2-dimensional (2D) construct, with their fixed or functional nature unresolved. This study aimed to examine the correlation between localized lines of conduction block (LOB) evident during baseline rhythm with lateral isthmus boundaries that 3-dimensionally constrain the VT isthmus as a hyperboloid structure. METHODS: A total of 175 VT activation maps were correlated with isochronal late activation maps during baseline rhythm in 106 patients who underwent catheter ablation for scar-related VT from 3 centers (42% nonischemic cardiomyopathy). An overt LOB was defined by a deceleration zone with split potentials (≥20 ms isoelectric segment) during baseline rhythm. A novel application of pacing within deceleration zone (≥600 ms) was implemented to unmask a concealed LOB not evident during baseline rhythm. LOB identified during baseline rhythm or pacing were correlated with isthmus boundaries during VT. RESULTS: Among 202 deceleration zones analyzed during baseline rhythm, an overt LOB was evident in 47%. When differential pacing was performed in 38 deceleration zones without overt LOB, an underlying concealed LOB was exposed in 84%. In 152 VT activation maps (2D=53, 3-dimensional [3D]=99), 69% of lateral boundaries colocalized with an LOB in 2D activation patterns, and the depth boundary during 3D VT colocalized with an LOB in 79%. In VT circuits with isthmus regions that colocalized with a U-shaped LOB (n=28), the boundary invariably served as both lateral boundaries in 2D and 3D. Overall, 74% of isthmus boundaries were identifiable as fixed LOB during baseline rhythm or differential pacing. CONCLUSIONS: The majority of VT circuit boundaries can be identified as fixed LOB from intrinsic or paced activation during sinus rhythm. Analysis of activation while pacing within the scar substrate is a novel technique that may unmask concealed LOB, previously interpreted to be functional in nature. An LOB from the perspective of a myocardial surface is frequently associated with intramural conduction, supporting the existence of a 3D hyperboloid VT circuit structure. Catheter ablation may be simplified to targeting both sides around an identified LOB during sinus rhythm.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Cicatriz , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Arritmias Cardíacas , Frecuencia Cardíaca/fisiología , Bloqueo Cardíaco
2.
J Cardiovasc Electrophysiol ; 35(1): 198-205, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38037864

RESUMEN

INTRODUCTION: The major limitation of the current cryoballoon (CB) system is a fixed 28 mm balloon-size. We sought to analyze real-world early experience with novel-sized adjustable CB. METHODS: This multicenter observational study included 140 consecutive atrial fibrillation patients (71 years, 94 men, 86 paroxysmal) who underwent pulmonary vein (PV) isolation using expandable diameter CB capable of ablation at 28 or 31 mm. RESULTS: Out of 544 targeted PVs, 526 (96.7%) were successfully isolated by a size-adjustable CB with a 770 [690-870] second median application dose, while the remaining 18 required touch-up ablation. Among them, 326 (62.0%) PVs were isolated by a 31 mm balloon, and the rate was significantly higher for upper than lower PVs (73.0% vs. 45.7%, p < .0001) and highest for right superior (78.5%) and lowest for right inferior (39.9%) PVs. The biophysical parameters and time to isolation were comparable between the 28 and 31 mm balloons, however, the real-time PV potential monitoring capability was significantly higher for 31 mm than 28 mm balloons for the left superior PV. The esophageal temperature reached 15°C during left inferior PV ablation significantly more often with 31 mm than 28 mm balloons (43.1% vs. 18.2%, p = .008). Right phrenic nerve injury (PNI) occurred in 9 (6.4%) patients during applications (6 right superior, 2 right inferior PVs), and most occurred with a 31 mm balloon. CONCLUSIONS: Our real-world early data demonstrated high acute efficacy and safety of the novel-sized adjustable CB. The biophysical parameters were similar between the 28 and 31 mm balloons. No marked decrease in the incidence of PNI was observed even with 31 mm balloons.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Femenino
3.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38588039

RESUMEN

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Asunto(s)
Fibrilación Atrial , Criocirugía , Traumatismos de los Nervios Periféricos , Nervio Frénico , Venas Pulmonares , Sistema de Registros , Humanos , Nervio Frénico/lesiones , Masculino , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Venas Pulmonares/cirugía , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Estudios Prospectivos , Incidencia , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/epidemiología , Traumatismos de los Nervios Periféricos/prevención & control , Persona de Mediana Edad , Resultado del Tratamiento , Ablación por Catéter/efectos adversos
4.
Pacing Clin Electrophysiol ; 47(1): 124-126, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37864811

RESUMEN

Recently, a novel size-adjustable cryoballoon has been introduced in clinical practice, which can be inflated to two different diameters (28 and 31 mm). The 31 mm cryoballoon is specifically designed to achieve better contact with remodeled pulmonary veins (PVs) that have wider ostia while avoiding deep cannulation, thereby potentially reducing the risk of phrenic nerve injury (PNI) associated with deep balloon cannulation. However, we encountered two cases of PNI during cryoballoon ablation using the novel system among our initial 25 consecutive case series. Herein, we present two cases that exhibited PNI during freezing of the right superior PV with a size-adjustable balloon. While larger balloons are expected to create a larger area of isolation, the safety of this novel balloon system needs to be evaluated in a large-scale clinical study.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Traumatismos de los Nervios Periféricos , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Nervio Frénico/lesiones , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/prevención & control , Traumatismos de los Nervios Periféricos/cirugía , Venas Pulmonares/cirugía , Resultado del Tratamiento
5.
Heart Vessels ; 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38494555

RESUMEN

Epicardial adipose tissue (EAT) induces inflammation in the atria and is associated with atrial fibrillation (AF). Several studies have examined the relationship between EAT volume (EAT-V) and density (EAT-D) and the presence of AF after catheter ablation. However, conclusions have been inconsistent. This study included 43 consecutive patients who underwent catheter ablation for AF and 30 control patients. EAT-V and EAT-D around the entire heart, entire atrium, left atrium (LA), and right atrium (RA) were measured in detail using reconstructed three-dimensional (3D) EAT images from dual-source computed tomography (CT). None of the measurements of EAT-V differed significantly between patients with AF and controls or between patients with recurrent AF and those without. On the other hand, all measurements of EAT-D were higher in patients with AF than in controls (entire atrium, p < 0.001; RA, p < 0.001; LA, p = 0.002). All EAT-D measurements were associated with the presence of AF. Among patients with AF who underwent ablation, all EAT-D measurements were higher in patients with recurrent AF than in those without. The difference was significant for EATRA-D (p = 0.032). All atrial EAT-D values predicted recurrent AF (EATRA-D: hazard ratio [HR], 1.208; 95% confidence interval [95% CI], 1.053-1.387; p = 0.007; EATLA-D: HR, 1.108; 95% CI 1.001-1.225; p = 0.047; EATatrial-D: HR, 1.174; 95% CI 1.040-1.325; p = 0.010). The most sensitive cutoffs for predicting recurrent AF were highly accurate for EATRA-D (area under the curve [AUC], 0.76; p < 0.01) and EATatrial-D (AUC = 0.75, p < 0.05), while the cutoff for EATLA-D had low accuracy (AUC, 0.65; p = 0.209). For predicting the presence of AF and recurrent AF after catheter ablation, 3D analysis of atrial EAT-D, rather than EAT-V, is useful.

6.
Heart Vessels ; 39(3): 240-251, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37872308

RESUMEN

Clinical outcomes after catheter ablation in patients with reduced left ventricular (LV) ejection fraction (EF) and atrial fibrillation (AF) remain unclear. This study aimed to explore the clinical outcomes of patients with arrhythmia-induced cardiomyopathy (AIC) and the influence of pharmacological treatment on clinical outcomes in patients with AIC after the procedure. Ninety-six patients with AF with a reduced LVEF (LVEF < 50%, 66.7 ± 10.9 years; 72 males) underwent AF ablation. AIC was defined as patients whose LVEF recovered ≥ 50% after catheter ablation (n = 67) and patients whose LVEF remained reduced were defined as non-AIC (n = 29). During a median follow-up of 25 (13-40) months, Kaplan-Meier analysis demonstrated that patients with AIC were associated with less frequent cardiovascular death (p = 0.025) and hospitalization for worsening heart failure (p < 0.001) than those without AIC. Freedom from AF recurrence was similar between the two groups (p = 0.47). In multivariate analysis, the LV end-diastolic diameter (p = 0.0002) and the CHA2DS2-VASc scores (p = 0.0062) were independent predictors of AIC. Among the 67 patients with AIC, no significant differences in baseline characteristics, except for LV chamber size and cryoballoon use, were observed between patients with AIC with (n = 31) and without renin-angiotensin system (RAS) inhibitors (n = 36). In the Kaplan-Meier analysis, cardiovascular death, hospitalization for worsening heart failure, and AF recurrence after catheter ablation did not differ between patients treated with and without RAS inhibitors (all p > 0.05). Catheter ablation in patients with AIC due to AF is associated with a good post-procedural prognosis.IRB information The study was approved by the Research Ethics Committee of the University of Fukui (No. 20220151) and clinical trial registration (UMIN000050391).


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Ablación por Catéter , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Masculino , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Volumen Sistólico , Función Ventricular Izquierda
7.
J Cardiovasc Electrophysiol ; 34(9): 1869-1877, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37529869

RESUMEN

BACKGROUND: Since the local impedance (LI) of the ablation catheter reflects tissue characteristics, the efficacy of higher power (HP) compared to lower power (LP) in LI-guided ablation may differ from other index-guided ablations. OBJECTIVE: This study aimed to assess the efficacy of HP ablation in LI-guided ablation of atrial fibrillation (AF). METHODS: A prospective observational study was conducted, enrolling patients undergoing de novo ablation for AF. Pulmonary vein isolation was performed using point-by-point ablation with a RHYTHMIA HDxTM Mapping System and an open-irrigated ablation catheter with mini-electrodes (IntellaNav MIFI OI). Ablation was stopped when the LI drop reached 30 ohms, three seconds after the LI plateaued, or when ablation time reached 30 s. To balance the baseline differences, a unique method was used in which the power was changed between HP (45 W to anterior wall/40 W to posterior wall) and LP (35 W/30 W) alternately for each adjacent point. RESULTS: A total of 551 ablations in 10 patients were analyzed (HP, n = 276; LP, n = 275). The maximum LI drop was significantly larger (HP: 28.3 ± 5.4 vs. LP: 24.8 ± 6.3 ohm), and the time to minimum LI was significantly shorter (HP: 15.0 ± 6.3 vs. LP: 19.3 ± 6.6 s) in the HP setting. The unipolar electrogram analysis of three patients revealed that the electrogram indicating transmural lesion formation was observed more frequently in the HP setting. CONCLUSION: In LI-guided ablation, the HP could achieve a larger LI drop and shorter time to minimum LI, which may result in more transmural lesion formation compared to a LP setting.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Impedancia Eléctrica , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Electrodos , Resultado del Tratamiento
8.
J Cardiovasc Electrophysiol ; 34(4): 888-897, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36852902

RESUMEN

BACKGROUND/OBJECTIVES: The QDOT-MICRO™ catheter allows very high-power and short-duration (vHPSD) ablation. This study aimed to investigate lesion characteristics using different ablation settings. METHODS: Radiofrequency applications (90 W/4 s, temperature-control mode with 55°C or 60°C target) were performed in excised porcine myocardium using three different approaches: single (SA), double nonrepetitive (DNRA), and double repetitive applications (DRA). Applications were performed with an interval of 1 min for DNRA, and without interval for DRA. RESULTS: A total of 480 lesions were analyzed. Lesion depth and volume were largest for DRA followed by DNRA and SA regardless of catheter direction (depth: 3.8 vs. 3.3 vs. 2.6 mm, p < .001 for all comparisons; volume: 176.6 vs. 145.1 vs. 97.0 mm3 , p < .001 for all comparisons). Surface area was significantly larger for DRA than for SA (45.1 vs. 38.3 mm2 , p < .001) and larger for DNRA than for SA (44.5 vs. 38.3 mm2 , p < .001), but was similar between DRA and DNRA (45.1 vs. 44.5 mm2 , p = .54). Steam-pops more frequently occurred for DRA than for SA (15.6% vs. 4.4%, p = .004) and DNRA (15.6% vs. 6.9%, p = .061), but the incidence was similar between SA and DNRA (4.4% vs. 6.9%, p = 1). Although surface area and lesion volume were larger in lesions with steam-pops than without steam-pops (46.5 vs. 38.1 mm2 , p = .018 and 128.3 vs. 96.8 mm3 , p = .068, respectively), lesions were not deeper (pop(+): 2.5 mm vs. pop(-): 2.6 mm, p = .75). CONCLUSIONS: DNRA produces larger lesions than SA without increasing the risk of steam-pops. DRA produces the largest lesions among the three groups, but with an increased risk of steam-pops. Even with steam-pops, lesions do not become deeper in vHPSD ablation.


Asunto(s)
Ablación por Catéter , Vapor , Porcinos , Animales , Ablación por Catéter/efectos adversos , Irrigación Terapéutica/efectos adversos , Diseño de Equipo , Catéteres
9.
J Cardiovasc Electrophysiol ; 34(8): 1708-1717, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37431258

RESUMEN

BACKGROUND: The impact of filtering on bipolar electrograms (EGMs) has not been systematically examined. We tried to clarify the optimal filter configuration for ventricular tachycardia (VT) ablation. METHODS: Fifteen patients with VT were included. Eight different filter configurations were prospectively created for the distal bipoles of the ablation catheter: 1.0-250, 10-250, 100-250, 30-50, 30-100, 30-250, 30-500, and 30-1000 Hz. Pre-ablation stable EGMs with good contact (contact force > 10 g) were analyzed. Baseline fluctuation, baseline noise, bipolar peak-to-peak voltage, and presence of local abnormal ventricular activity (LAVA) were compared between different filter configurations. RESULTS: In total, 2276 EGMs with multiple bipolar configurations in 246 sites in scar and border areas were analyzed. Baseline fluctuation was only observed in the high-pass filter of (HPF) ≤ 10 Hz (p < .001). Noise level was lowest at 30-50 Hz (0.018 [0.012-0.029] mV), increased as the low-pass filter (LPF) extended, and was highest at 30-1000 Hz (0.047 [0.041-0.061] mV) (p < .001). Conversely, the HPF did not affect the noise level at ≤30 Hz. As the HPF extended to 100 Hz, bipolar voltages significantly decreased (p < .001), but were not affected when the LPF was extended to ≥100 Hz. LAVAs were most frequently detected at 30-250 Hz (207/246; 84.2%) and 30-500 Hz (208/246; 84.6%), followed by 30-1000 Hz (205/246; 83.3%), but frequently missed at LPF ≤ 100 Hz or HPF ≤ 10 Hz (p < .001). A 50-Hz notch-filter reduced the bipolar voltage by 43.9% and LAVA-detection by 34.5% (p < .0001). CONCLUSION: Bipolar EGMs are strongly affected by filter settings in scar/border areas. In all, 30-250 or 30-500 Hz may be the best configuration, minimizing the baseline fluctuation, baseline noise, and detecting LAVAs. Not applying the 50-Hz notch filter may be beneficial to avoid missing VT substrate.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Cicatriz , Ablación por Catéter/efectos adversos
10.
J Cardiovasc Electrophysiol ; 34(4): 908-917, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36906814

RESUMEN

INTRODUCTION: The QDOT-MicroTM catheter is a novel irrigated contact force (CF) sensing catheter which benefits from thermocouples for temperature monitoring, allowing temperature-flow-controlled (TFC) ablation. We compared lesion metrics at fixed ablation index (AI) value during TFC-ablation and conventional power-controlled (PC)-ablation. METHODS: A total of 480 RF-applications were performed on ex-vivo swine myocardium with predefined AI targets (400/550) or until steam-pop occurred, using the QDOT-MicroTM (TFC-ablation) and Thermocool SmartTouch SFTM (PC-ablation). RESULTS: Both TFC-ablation and PC-ablation produced similar lesions in volume (218 ± 116 vs. 212 ± 107 mm3 , p = .65); however, lesions using TFC-ablation were larger in surface area (41.3 ± 8.8 vs. 34.8 ± 8.0 mm2 , p < .001) and shallower in depth (4.0 ± 1.0 vs. 4.2 ± 1.1 mm, p = .044). Average power tended to be lower in TFC-alation (34.2 ± 8.6 vs. 36.9 ± 9.2, p = .005) compared to PC-ablation due to automatic regulation of temperature and irrigation-flow. Although steam-pops were less frequent in TFC-ablation (24% vs. 15%, p = .021), they were particularly observed in low-CF (10 g) and high-power ablation (50 W) in both PC-ablation (n = 24/240, 10.0%) and TFC-ablation (n = 23/240, 9.6%). Multivariate analysis revealed that high-power, low-CF, long application time, perpendicular catheter orientation, and PC-ablation were risk factors for steam-pops. Furthermore, activation of automatic regulation of temperature and irrigation-flow was independently associated with high-CF and long application time while ablation power had no significant relationship. CONCLUSIONS: With a fixed target AI, TFC-ablation reduced the risk of steam-pops, producing similar lesions in volume, but with different metrics in this ex-vivo study. However, lower CF and higher power in fixed-AI ablation may increase the risk of steam-pops.


Asunto(s)
Ablación por Catéter , Vapor , Porcinos , Animales , Temperatura , Ablación por Catéter/efectos adversos , Irrigación Terapéutica/efectos adversos , Diseño de Equipo
11.
J Cardiovasc Electrophysiol ; 34(8): 1671-1680, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37337433

RESUMEN

INTRODUCTION: Little is known about the impact of blood-pool local impedance (LI) on lesion characteristics and the incidence of steam pops. METHODS: Radiofrequency applications at a range of powers (30, 40, and 50 W), contact forces (CF) (5, 15, and 25 g), and durations (15, 30, 45, and 120 s) using perpendicular/parallel catheter orientation were performed in 40 excised porcine preparations, using a catheter capable of monitoring LI (StablePoint©, Boston Scientific). To simulate the variability in blood-pool impedance, the saline-pool LI was modulated by calibrating saline concentrations. Lesion characteristics were compared under three values of saline-pool LI: 120, 160, and 200 Ω. RESULTS: Of 648 lesions created, steam pops occurred in 175 (27.0%). When power, CF, time, and catheter orientation were adjusted, ablation at a saline-pool impedance of 160 or 200 Ω more than doubled the risk of steam pops compared with a saline-pool impedance of 120 Ω (Odds ratio = 2.31; p = .0002). Lesions in a saline-pool impedance of 120 Ω were significantly larger in surface area (50 [38-62], 45 [34-56], and 41 [34-60] mm2 for 120, 160, and 200 Ω, p < .05), but shallower in depth (4.0 [3-5], 4.4 [3.2-5.3], and 4.5 [3.8-5.5] mmfor 120, 160, and 200 Ω, respectively, p < .05) compared with the other two settings. The correlation between the absolute LI-drop and lesion size weakened as the saline-pool LI became higher (e.g., 120 Ω group (r2 = .30, r2 = .18, and r2 = .16, respectively for 120, 160, and 200 Ω), but the usage of %LI-drop (= absolute LI-drop/initial LI) instead of absolute LI-drop may minimize this effect. CONCLUSIONS: In an experimental model, baseline saline-pool impedance significantly affects the lesion metrics and the risk of steam pops.


Asunto(s)
Ablación por Catéter , Vapor , Porcinos , Animales , Impedancia Eléctrica , Benchmarking , Ablación por Catéter/efectos adversos , Solución Salina
12.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38096246

RESUMEN

AIMS: The usefulness of coronary venous system mapping has been reported for assessing intramural and epicardial substrates in patients with scar-related ventricular tachycardia (VT). However, there has been little data on mapping from coronary arteries. We investigated the safety and utility of mapping from coronary arteries with a novel over-the-wire multielectrode catheter in scar-related VT patients. METHODS AND RESULTS: Ten consecutive scar-related VT patients with non-ischaemic cardiomyopathy who underwent mapping from a coronary artery were analysed. Six patients underwent simultaneous coronary venous mapping. High-density maps were created by combining the left ventricular endocardium and coronary vessels. Substrate maps were created during the baseline rhythm with 2438 points (IQR 2136-3490 points), including 329 (IQR 59-508 points) in coronary arteries. Abnormal bipolar electrograms were successfully recorded within coronary arteries close to the endocardial substrate in seven patients. During VT, isthmus components were recorded within the coronary vessels in three patients with no discernible isthmus components on endocardial mapping. The ablation terminated the VT from an endocardial site opposite the earliest site in the coronary arteries in five patients. CONCLUSION: The transcoronary mapping with an over-the-wire multielectrode catheter can safely record abnormal bipolar electrograms within coronary arteries. Additional mapping data from the coronary vessels have the potential to assess three-dimensional ventricular substrates and circuit structures in scar-related VT patients.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Cicatriz/complicaciones , Cicatriz/diagnóstico por imagen , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Arritmias Cardíacas , Ventrículos Cardíacos , Endocardio , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
13.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37428890

RESUMEN

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Humanos , Estudios Retrospectivos , Técnicas Electrofisiológicas Cardíacas , Taquicardia , Atrios Cardíacos , Resultado del Tratamiento
14.
Europace ; 25(4): 1400-1407, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36892146

RESUMEN

AIMS: The optimal anticoagulation regimen in patients with end-stage kidney disease (ESKD) undergoing atrial fibrillation (AF) catheter ablation is unknown. We sought to describe the real-world practice of peri-procedural anticoagulation management in patients with ESKD undergoing AF ablation. METHODS AND RESULTS: Patients with ESKD on haemodialysis undergoing catheter ablation for AF in 12 referral centres in Japan were included. The international normalized ratio (INR) before and 1 and 3 months after ablation was collected. Peri-procedural major haemorrhagic events as defined by the International Society on Thrombosis and Haemostasis, as well as thromboembolic events, were adjudicated. A total of 347 procedures in 307 patients (67 ±9 years, 40% female) were included. Overall, INR values were grossly subtherapeutic [1.58 (interquartile range: 1.20-2.00) before ablation, 1.54 (1.22-2.02) at 1 month, and 1.22 (1.01-1.71) at 3 months]. Thirty-five patients (10%) suffered major complications, the majority of which was major bleeding (19 patients; 5.4%), including 11 cardiac tamponade (3.2%). There were two peri-procedural deaths (0.6%), both related to bleeding events. A pre-procedural INR value of 2.0 or higher was the only independent predictor of major bleeding [odds ratio, 3.3 (1.2-8.7), P = 0.018]. No cerebral or systemic thromboembolism occurred. CONCLUSION: Despite most patients with ESKD undergoing AF ablation showing undertreatment with warfarin, major bleeding events are common while thromboembolic events are rare.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fallo Renal Crónico , Tromboembolia , Humanos , Femenino , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Anticoagulantes/efectos adversos , Hemorragia/inducido químicamente , Tromboembolia/etiología , Tromboembolia/prevención & control , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/terapia , Ablación por Catéter/efectos adversos , Sistema de Registros
15.
Europace ; 25(2): 374-381, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36414239

RESUMEN

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodos , Nervio Frénico , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
16.
Circ J ; 87(12): 1757-1764, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37899173

RESUMEN

BACKGROUND: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30-50 W), contact force (10 g and 20 g), duration (10-60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation. CONCLUSIONS: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.


Asunto(s)
Ablación por Catéter , Solución Salina , Animales , Porcinos , Ventrículos Cardíacos/patología , Corazón , Catéteres , Ablación por Catéter/métodos , Diseño de Equipo , Impedancia Eléctrica
17.
Pacing Clin Electrophysiol ; 46(6): 515-518, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36690018

RESUMEN

The 12-lead electrocardiogram (ECG) is a fundamental modality to help determine the mechanism and the localization of atrial tachycardias (ATs). Although macroreentrant ATs and focal ATs typically show F-waves and discrete P-waves respectively on the 12-lead ECG, this is not universally the case in scar-related ATs.1, We present three cases clearly showing the discrepancy between the AT morphology on the 12-lead ECG and the AT-mechanism.


Asunto(s)
Ablación por Catéter , Taquicardia Atrial Ectópica , Taquicardia Supraventricular , Humanos , Cicatriz , Electrocardiografía
18.
Pacing Clin Electrophysiol ; 46(12): 1536-1545, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37957924

RESUMEN

BACKGROUND AND AIMS: The safety evaluation of TactiFlex, a novel contact-force sensing catheter with a flexible 4-mm tip irrigated through laser-cut kerfs, has been ongoing. This study aimed to verify the safety of this type of catheter. METHODS: Study 1: Radiofrequency (RF) applications at a range of powers (30-50 W), contact forces (10-20 g), and durations (10-60 s) using perpendicular/parallel catheter orientation with half-normal (HNS) or normal saline irrigation were compared between TactiFlex (4-mm tip) and TactiCath (3.5-mm tip) with temperature-controlled mode in excised porcine hearts. Study 2: The relation between RF applications using TactiFlex and the incidence of steam-pops in the real clinical cases were examined. RESULTS: Study-1: 576 RF lesions were examined. TactiFlex demonstrated a significantly lower risk of steam-pops (5[1.7%] vs. 59[20.5%], p < .0001). Compared to 3.5-mm-tip catheter (TactiCath), 4-mm-tip catheter (TactiFlex) produced smaller lesion volume at perpendicular (193[98-554]mm3 vs. 263[139-436]mm3 , p < .0001), but relatively similar lesion volume at parallel contact (243[105-443]mm3 vs. 278[180-440]mm3 , p = .06). HNS-irrigation tended to increase the lesion volume in both catheters and to increase the incidence of steam-pops with TactiCath, but not with TactiFlex. The cut-off value of %impedance-drop ( = absolute impedance-drop/initial impedance) of 20% predicted steam-pops with a sensitivity = 100% and specificity = 89.6% in TactiFlex. Study-2: 5496 RF applications in 84 patients (51AFs/8ATs/3AVNRTs/4AVRTs/17PVCs/4VTs) using TactiFlex were analyzed. Four steam-pops (0.07%) in three patients with pericardial effusion were observed (%impedance-drop = 24%/26%/29%/35%, respectively). The cut-off value of %impedance-drop = 20%, derived from ex-vivo study, showed sensitivity = 100% and specificity = 90.1% in detecting steam-pops. CONCLUSION: TactiFlex reduced the risk of steam-pops than TactiCath. %impedance-drop ≤ 20% may be reasonable for safely use with a sufficient safety margin. For 4-mm-tip catheter, parallel-contact may be recommended for larger lesion creation.


Asunto(s)
Ablación por Catéter , Vapor , Humanos , Animales , Porcinos , Irrigación Terapéutica , Diseño de Equipo , Catéteres
19.
Heart Vessels ; 38(7): 929-937, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36823474

RESUMEN

Successful atrial fibrillation (AF) ablation can improve reduced left ventricular ejection fraction (LVEF) with AF, which is defined as arrhythmia-induced cardiomyopathy (AIC). However, it is difficult to pre-procedurally predict the presence of AIC. We aimed to explore the pre-procedural predictors of AIC in patients with AF and reduced LVEF. This study included 60 patients with a reduced LVEF (LVEF < 50%; 69.1 ± 8.8 years; 45 men) who underwent successful AF ablation. Responders were defined as patients whose LVEF post-procedurally improved to the normal range (≥ 50%). Multivariate analysis revealed that the log-transformed pre-procedural troponin I (TnI) levels (odds ratio [OR] = 0.059; 95% confidence interval [CI] = 0.0052-0.42, p = 0.003) and age (OR = 0.91; 95% CI = 0.82-1.00, p = 0.044) were independent predictors of post-procedural LVEF recovery; further, low TnI levels (< 11.1 pg/ml) predicted LVEF recovery (sensitivity, 79.1%; specificity, 76.5%; positive predictive value, 89.5%; and negative predictive value, 59.1%). There were no significant differences in TnI levels between the baseline and 1 month after the procedure. However, four patients with high baseline TnI levels showed a > 50% reduction in the TnI levels post-procedurally, with three of these patients showing LVEF recovery. Low pre-procedural TnI levels can predict LVEF recovery after successful AF ablation in patients with reduced LVEF.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Disfunción Ventricular Izquierda , Masculino , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Función Ventricular Izquierda , Troponina I , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/etiología , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico
20.
J Cardiovasc Electrophysiol ; 33(1): 40-45, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34676946

RESUMEN

BACKGROUND: Cavo-tricuspid isthmus (CTI) linear ablation is performed not only for atrial flutter (AFL) but empirically during atrial fibrillation (AF) ablation in real-world practice.  PURPOSE: We sought to evaluate the safety and durability of the CTI ablation.  METHODS: This retrospective study included 1078 consecutive patients who underwent a CTI ablation. AFL was documented before or during the procedure in 249 (23.1%) patients, and an empirical CTI and AF ablation were performed in 829 (76.9%) patients.  RESULTS: CTI block was successfully created in 1051 (97.5%) patients with a 10.3 ± 6.6 min total radiofrequency time. Repeat procedures were performed for recurrent arrhythmias in 187 (17.3%) patients at a median of 11.0 (5.0-30.0) months postprocedure, and conduction resumption was identified in 68/174 (39.1%). Among those undergoing a CTI ablation with an AF ablation, the durability was significantly higher in those with than without documented AFL (78.1% vs. 58.2%, p = .031).  The total radiofrequency time was significantly shorter (9.0 ± 5.3 vs. 10.0 ± 6.4 [mins], p = .024) and durability significantly higher (78.1 vs. 58.7[%], p = .043) in the large-tip than irrigated-tip catheter group. Iatrogenic AFL was observed after the empiric CTI ablation in 11 (1.3%) patients. Procedure-related complications occurred in 15 (1.4%) patients. Eight patients experienced coronary artery spasms, including one with ventricular fibrillation following ST elevation on the ward. The other six patients experienced transient atrioventricular block and one experienced cardiac tamponade requiring drainage.  CONCLUSIONS: Despite a high acute CTI ablation success, the conduction block durability was relatively low after the empiric ablation. An empiric CTI ablation at the time of the AF ablation is not recommended.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento