Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 268
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(11): 940-949, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38243821

RESUMEN

BACKGROUND AND AIMS: Mitral valve surgery and, more recently, mitral transcatheter edge-to-edge repair (TEER) are the two treatments of severe mitral regurgitation in eligible patients. Clinical comparison of both therapies remains limited by the number of patients analysed. The objective of this study was to analyse the outcomes of mitral TEER vs. isolated mitral valve surgery at a nationwide level in France. METHODS: Based on the French administrative hospital discharge database, the study collected information for all consecutive patients treated for mitral regurgitation with isolated TEER or isolated mitral valve surgery between 2012 and 2022. Propensity score matching was used for the analysis of outcomes. RESULTS: A total of 57 030 patients were found in the database. After matching on baseline characteristics, 2160 patients were analysed in each arm. At 3-year follow-up, TEER was associated with significantly lower incidence of cardiovascular death (hazard ratio 0.685, 95% confidence interval 0.563-0.832; P = .0001), pacemaker implantation, and stroke. Non-cardiovascular death (hazard ratio 1.562, 95% confidence interval 1.238-1.971; P = .0002), recurrent pulmonary oedema, and cardiac arrest were more frequent after TEER. No significant differences between the two groups were observed regarding all-cause death (hazard ratio 0.967, 95% confidence interval 0.835-1.118; P = .65), endocarditis, major bleeding, atrial fibrillation, and myocardial infarction. CONCLUSIONS: Our results suggest that TEER for severe mitral regurgitation was associated with lower cardiovascular mortality than mitral surgery at long-term follow-up. Pacemaker implantation and stroke were less frequently observed after TEER.


Asunto(s)
Fibrilación Atrial , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Accidente Cerebrovascular , Humanos , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Accidente Cerebrovascular/epidemiología , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Bases de Datos Factuales , Resultado del Tratamiento
2.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-38820201

RESUMEN

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Asunto(s)
Endocarditis , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/mortalidad , Endocarditis/cirugía , Endocarditis/mortalidad , Remoción de Dispositivos , Prótesis Valvulares Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Resultado del Tratamiento , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
3.
Eur Heart J ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

4.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-37624856

RESUMEN

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco
5.
Am Heart J ; 270: 86-94, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38309610

RESUMEN

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Válvula Aórtica/cirugía , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Puente de Arteria Coronaria , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
6.
Heart Fail Rev ; 29(1): 227-234, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37950833

RESUMEN

As the survival after heart transplantation (HTx) is steadily improving, an increasing number of patients with late cardiac pathologies such as valvular disease is expected to rise. Nevertheless, no guidelines for indication of redo cardiac surgery after HTx exists. The aim of the present systematic review is to describe the results reported in the literature of surgical management of severe aortic and/or mitral valve disease. A systematic review was conducted including studies reporting on adult patients with severe mitral or aortic valve pathology needing surgery after their previous HTx. Exclusion criteria consisted in surgery with no left heart valve surgery, concomitant valve surgery during heart transplant, transcatheter interventions, and heterotopic HTx. A total of 35 papers met our inclusion criteria out of 2755 potentially eligible studies with 44 mitral valve surgery patients and 20 aortic valve surgery patients. In the entire population, the mean time from HTx to reintervention was 6.19 ± 5.22 years. After a mean follow-up of 2.78 ± 3.54 years and 1.53 ± 2.26 years from reintervention, 65.6% mitral and 86.7% aortic patients were reported as alive, respectively. As guidelines on cardiac surgery after HTx are currently lacking, left-sided valvular cardiac reinterventions can be considered a possible therapeutic approach in carefully selected patients. These interventions may not only improve the patient's functional status and survival, but may ultimately reduce the need for re-transplantation due to the chronic shortage of donor hearts. However, the support of more robust data is warranted.


Asunto(s)
Cardiopatías , Trasplante de Corazón , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Humanos , Trasplante de Corazón/efectos adversos , Resultado del Tratamiento , Donantes de Tejidos , Enfermedades de las Válvulas Cardíacas/cirugía , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
7.
Heart Fail Rev ; 29(1): 219-226, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37851119

RESUMEN

Tricuspid regurgitation (TR) is the most common valvular pathology after heart transplantation (HTx) and endomyocardial biopsy (EMB) remains responsible for the majority of cases due to the high probability of structural valve damage. The aim of the present review was to describe the results of surgical management of severe tricuspid regurgitation through tricuspid valve replacement (TVR) after a previous HTx. A systematic review was conducted by searching Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane databases until June 2023 for publications reporting patients undergoing TVR surgery after a previous HTx. If no right heart valve surgery was undertaken, or a heterotopic heart transplant was performed, or if the concomitant procedure was performed during the transplant itself, the paper was excluded. Twenty articles met our inclusion criteria out of 1532 potentially eligible studies, with a total of 300 patients. Mean age was 55.1 ± 9.6 years, and 85.1% were male. The mean number of EMB per patient was 31.1 ± 5.5 with a mean time between HTx and TVR of 7.64 ± 3.31 years. Bioprostheses were used in 83.3% of cases and 75.0% of patients with a bioprosthesis were reported as alive at last follow-up. Tricuspid valve repair is a valuable option, but these patients will be susceptible to recurrent TR after EMB. TVR with a bioprosthesis may provide the optimal solution for this subset of patients, as EMB is not feasible with a mechanical valve.


Asunto(s)
Trasplante de Corazón , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Masculino , Persona de Mediana Edad , Femenino , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Prótesis Valvulares Cardíacas/efectos adversos , Trasplante de Corazón/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos
8.
Eur J Clin Invest ; : e14241, 2024 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-38767226

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.

9.
Catheter Cardiovasc Interv ; 103(7): 1101-1110, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38532517

RESUMEN

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Estimulación Cardíaca Artificial , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Falla de Prótesis , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-37930776

RESUMEN

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Masculino , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Índice de Severidad de la Enfermedad
11.
Catheter Cardiovasc Interv ; 102(2): 318-327, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37354444

RESUMEN

BACKGROUND: Transcatheter mitral valve implantation (TMVI) is a novel therapeutic option for treating symptomatic mitral valve disease. Evaluating patient anatomical suitability is a critical step in the TMVI screening process, but currently requires specialized software and computerized device models. AIMS: This analysis sought to assess the effectiveness of simple and standardized multislice computed tomography (MSCT) anatomic measurements for their ability to discriminate between patients who passed anatomical screening for Tendyne™ TMVI. METHODS: Subjects screened for the Tendyne Expanded Clinical Study from January 2016 through September 2019 were included. Core laboratory screening measurements included mitral annular (MA) dimensions at end-systole and end-diastole, simulated device implantation, and neo-left ventricular outflow tract (LVOT) area. Additionally, nine standard measurements of patient anatomy were assessed for their predictive value of patients passing the anatomic screening process. RESULTS: Out of 496 subjects screened for eligibility, 257 subjects met clinical eligibility criteria with MA dimensions within the manufacturer's suggested range: 153 (59.5%) underwent TMVI while 104 (40.5%) were excluded from the study for other anatomic reasons (76% due to risk of LVOT obstruction). CT-derived left ventricular end-systole diameter (LVESD) had the highest discriminatory power for predicting TMVI anatomical suitability (area under the curve of 0.908, p < 0.0001). The mitral inter-commissural (IC) dimension was best predictive of annular dimensions being within range, with dimensions <30 or >50 mm resulting in a negative predictive value of 94.4%. CONCLUSIONS: MSCT-derived mitral IC dimension and LVESD easily performed measures that are effective predictors of anatomical suitability or screen failure for this tether-based TMVI device.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco , Resultado del Tratamiento
12.
Eur Heart J ; 43(7): 654-662, 2022 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-34586392

RESUMEN

AIMS: Isolated tricuspid valve surgery (ITVS) is considered to be a high-risk procedure, but in-hospital mortality is markedly variable. This study sought to develop a dedicated risk score model to predict the outcome of patients after ITVS for severe tricuspid regurgitation (TR). METHODS AND RESULTS: All consecutive adult patients who underwent ITVS for severe non-congenital TR at 12 French centres between 2007 and 2017 were included. We identified 466 patients (60 ± 16 years, 49% female, functional TR in 49%). In-hospital mortality rate was 10%. We derived and internally validated a scoring system to predict in-hospital mortality using multivariable logistic regression and bootstrapping with 1000 re-samples. The final risk score ranged from 0 to 12 points and included eight parameters: age ≥70 years, New York Heart Association Class III-IV, right-sided heart failure signs, daily dose of furosemide ≥125 mg, glomerular filtration rate <30 mL/min, elevated bilirubin, left ventricular ejection fraction <60%, and moderate/severe right ventricular dysfunction. Tricuspid regurgitation mechanism was not an independent predictor of outcome. Observed and predicted in-hospital mortality rates increased from 0% to 60% and from 1% to 65%, respectively, as the score increased from 0 up to ≥9 points. Apparent and bias-corrected areas under the receiver operating characteristic curves were 0.81 and 0.75, respectively, much higher than the logistic EuroSCORE (0.67) or EuroSCORE II (0.63). CONCLUSION: We propose TRI-SCORE as a dedicated risk score model based on eight easy to ascertain parameters to inform patients and physicians regarding the risk of ITVS and guide the clinical decision-making process of patients with severe TR, especially as transcatheter therapies are emerging (www.tri-score.com).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Adulto , Anciano , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Mortalidad Hospitalaria , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico , Función Ventricular Izquierda
13.
J Card Fail ; 28(4): 604-613, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35105522

RESUMEN

BACKGROUND: This is first-in-man investigation of an implantable Heartech left ventricular partitioning device (LVPD) therapy for chronic heart failure (HF) after a myocardial infarction. METHODS AND RESULTS: Initially, 16 patients were chosen from 3 cardiac centers within China. All patients were treated with percutaneous ventricular restoration involving the Heartech LVPD implantation. Major adverse cardiovascular and cerebrovascular events were documented. Functional status, echocardiograph evaluation, European five-dimensional health scale, 6-minute walk test before the procedure and at postoperative follow-ups were recorded. We demonstrated successful implantation and device function with a success rate of 93.75%. One patient suffered a fatal myocardial infarction within the 12 ± 1 month follow-up. However, other patients did not report any major adverse cardiovascular and cerebrovascular events at their 12 ± 1 month follow-ups. After the operation, the average left ventricular end-systolic volume index decreased dramatically (66.00 mL/m2, interquartile range [IQR] 63.00-89.00 mL/m2 vs 48.00 mL/m2, IQR 32.25-68.25 mL/m2, P = .001), along with the left ventricular end-diastolic volume index (105.00 mL/m2, IQR 90.00-130.00 mL/m2 vs 76.50 mL/m2, IQR 57.75-120.25 mL/m2, P = .002). The left ventricular ejection fraction (35.00%, IQR 27.00-38.00% vs 42.50%, IQR 34.75-50.25%, P = .003), 6-minute walk test (383.13 ± 108.70 m vs 491.17 ± 118.44 m, P = .01), and European five-dimensional health scale (65.93 ± 11.25 vs 82.50 ± 5.44, P < .001), in turn, improved significantly. CONCLUSIONS: In our study, the Heartech LVPD was demonstrated as both safe and effective in reducing LV volume, enhancing LV function after implantation. These results remain constant at least till the 12 month follow-up. (Trial Registration: NCT02938637.).


Asunto(s)
Insuficiencia Cardíaca , Infarto del Miocardio , Humanos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/cirugía , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
14.
Catheter Cardiovasc Interv ; 99(1): 171-178, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34331844

RESUMEN

OBJECTIVES: The Evolut R FORWARD study confirmed safety and effectivenesss of the Evolut R THV in routine clinical practice out to 1 year. Herein, we report the final 3-year clinical follow up of the FORWARD study. BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a proven alternative to surgery in elderly patients with symptomatic severe aortic stenosis. Long-term clinical outcome data with the Evolut R platform are scarce. METHODS: FORWARD is a prospective multicenter observational study that evaluated the Evolut R system in routine clinical practice at 53 centres. Eligible patients had symptomatic native aortic valve stenosis or failed surgical aortic bioprosthesis and elevated operative risk per Heart-Team assessment. TAVR was attempted in 1039 patients. RESULTS: Mean age was 81.8 ± 6.2 years, 64.9% were women, STS score was 5.5 ± 4.5% and 34.2% were frail. Rates of all-cause mortality and disabling stroke were 24.8% and 4.8% at 3 years. Early need for a new pacemaker implantation after TAVR (all-cause mortality: with new PPI; 21.0% vs. without; 22.8%, p = 0.55) and the presence of > trace paravalvular regurgitation (all-cause mortality: no or trace; 22.0% vs. ≥ mild; 25.5%, p = 0.29) did not affect survival. Between 1 and 3 years incidence rates of valve related intervention, endocarditis and clinically relevant valve thrombosis were low. CONCLUSIONS: The Evolut R valve maintained a favorable safety profile through 3 years in routine clinical practice. Rates of transcatheter heart valve-related adverse events were low.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
BMC Cardiovasc Disord ; 22(1): 445, 2022 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-36243693

RESUMEN

BACKGROUND: Success rate of transcatheter aortic valve replacement (TAVR) in aortic regurgitation (AR) patients is relatively low on account of the absence of calcified anchoring structures. Morphological classification and corresponding TAVR strategies for AR are lacking yet. METHODS: The AURORA study is a prospective, multicenter, single-arm cohort study to evaluate the safety and efficacy of transfemoral TAVR for severe AR in patients with high or prohibitive risk for surgery. Patients who are ≥ 65 years and diagnosed with severe pure AR as defined by the Echocardiographic Core Laboratory will be consecutively enrolled for further multidetector computed tomography (MDCT) scanning and multiplanar analyses. Based on a new anatomical classification and dual anchoring theory, patients will be classified into 4 types according to the level of the anchoring area. Types 1, 2 and 3 (at least 2 anchoring areas) will undergo the TAVR procedure with a domestic Chinese self-expanding valve (VitaFlow Valve, MicroPort, Shanghai, China), whereas type 4 (0 or 1 anchoring area) patients will be considered unsuitable for TAVR and will receive medical treatment. Our goal is to recruit 100 patients to account for 10% missing data or loss of patients to follow-up. Procedural, 30-day, 6-month and 12-month outcomes will be assessed according to Valve Academic Research Consortium-3 criteria. DISCUSSION: The AURORA study will establish a new AR anatomical classification based on dual anchoring theory through MDCT multiplanar measurement and assess the safety and efficacy of TAVR guided by this new classification and strategy in AR patients. TRIAL REGISTRATION: This Study was registered at Chinses Clinical Trial Registry. The registration number: ChiCTR2200055415; The date of registration: 9, January 2022; The URL of the registration: http://www.chictr.org.cn/showproj.aspx?proj=141209 .


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , China , Estudios de Cohortes , Humanos , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Echocardiography ; 39(12): 1571-1580, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36376261

RESUMEN

BACKGROUND: The success of transcatheter aortic valve replacement (TAVR) in native aortic regurgitation (AR) is limited by the absence of calcified anchoring structures. We sought to evaluate transfemoral TAVR in patients with native AR using a novel aortic root imaging classification. METHODS: From March to November 2021, 81 patients with severe AR were prospectively enrolled in 2 cardiac centers in China. All were evaluated using multidetector computed tomography (MDCT) and classified into 4 anatomic types in reference to transcatheter heart valve (THV) anchoring: Type 1: anchoring at the left ventricular outflow tract (LVOT), annulus, and ascending aorta (AA); Type 2: anchoring at the annulus and AA; Type 3: anchoring at the annulus and LVOT; and Type 4: anchoring at only 1 level or none at all. Based on the dual-anchoring strategy, patients with Types 1-3 were considered TAVR candidates. Procedural and 30-day outcomes were assessed according to Valve Academic Research Consortium-3 definitions. RESULTS: TAVR was performed in 32 (39.5%) patients (71.9 ± 8.0 years of age, 71.9% were male) using 2 self-expanding THVs. Types 1, 2, and 3 comprised 13 (40.6%), 11 (34.4%), and 8 (25.0%) cases, respectively. The procedural and device success rates were 100% and 93.8%, respectively, with 2 THV migration. Eight patients (25.0%) required a permanent pacemaker, and 2 (6.3%) developed moderate paravalvular leaks. No deaths or other major complications occurred during the study. CONCLUSIONS: The novel anatomic classification and dual-anchoring strategy were associated with a high procedural success rate with favorable short-term safety and clinical outcomes.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano , Femenino , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , China
17.
J Card Surg ; 37(9): 2633-2639, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35598309

RESUMEN

OBJECTIVES: The hypothermic circulatory arrest is a major limitation of the frozen elephant trunk (FET) technique, associated with a high incidence of postoperative mobility and mortality. The aim of this study was to evaluate the surgical outcomes of patients suffering from different aortic arch diseases treated with the release and perfuse technique (RPT). METHODS: We retrospectively reviewed the records of patients who had undergone aortic arch repair with the RPT at our Institution between October 2019 and September 2021. Preoperative, intra-operative, and postoperative data were collected. RESULTS: A total of 18 patients undergoing aortic arch surgery with the use of RPT were analyzed. Twelve of them (67%) were males, and the median age of the entire cohort was 67 (56-73) years. The primary indications for surgery included acute type A aortic dissection (50%), chronic type B aortic dissection (33%), and chronic aneurysms (17%). The median cardiopulmonary bypass-, aortic cross-clamp- and circulatory arrest times were 163 (147-213) min, 69 (51-120) min, and 10 (8-13) min, respectively. The median intensive care unit and hospital stay were 4 (2-7) and 12 (11-16) days, respectively. One patient (6%) died during the first 30 days after surgery. CONCLUSIONS: Considering the anatomical limitations related to the use of this technique, the RPT can be safely performed and could represent a promising strategy to reduce the circulatory arrest time during aortic arch surgery. Nevertheless, further studies are required to demonstrate its efficacy.


Asunto(s)
Aneurisma de la Aorta Torácica , Enfermedades de la Aorta , Disección Aórtica , Implantación de Prótesis Vascular , Anciano , Disección Aórtica/etiología , Disección Aórtica/cirugía , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/cirugía , Enfermedades de la Aorta/cirugía , Implantación de Prótesis Vascular/métodos , Femenino , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
18.
J Card Surg ; 37(9): 2564-2570, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35726653

RESUMEN

BACKGROUND AND AIM OF THE STUDY: To evaluate whether the simplified valve-sparing technique (SVST) implies clinical outcomes comparable or not with those of established David technique in the surgery of aortic root. METHODS: We collected the records of patients who had undergone aortic root surgery with the SVST or standard David technique (SDT) at our institution between January 2009 and December 2018. The primary endpoints were the incidence of all-cause death, reoperation for any reason, and postoperative complications. The secondary endpoint was the midterm incidence of reoperation for aortic valve regurgitation. RESULTS: A total of 169 patients who underwent aortic root surgery were analyzed. SDT and SVST were performed in 48 (28.4%) and in 121 (71.6%) patients, respectively. Thirty-day mortality occurred in 0% and 0.8% of patients in the SDT and SVST groups, respectively. The rate of postoperative new permanent pacemaker implantation was 6.3% (three patients) and 0.8% (one patient) in SDT and SVST cohort, respectively (p = .07). The incidence of postoperative thromboembolic stroke was 6.3% and 2.5% in SDT and SVST groups, respectively (p = .23). The median follow-up time was 29 (23-47) months. During the FU period, no differences were found between two cohorts in terms of all-cause mortality (p = .99), the incidence of reoperation (p = .19), and incidence of aortic valve regurgitation requiring reoperation (p = .58). CONCLUSIONS: The SVST appears to be safe and feasible showing early clinical results comparable to the SDT. Nevertheless, further studies with larger series and long-term follow-ups are required to demonstrate its safety and efficacy.


Asunto(s)
Aneurisma de la Aorta , Insuficiencia de la Válvula Aórtica , Implantación de Prótesis Vascular , Aneurisma de la Aorta/cirugía , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Estudios de Factibilidad , Humanos , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
19.
Circulation ; 141(4): 243-259, 2020 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-31736356

RESUMEN

BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.


Asunto(s)
Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Masculino , Tasa de Supervivencia
20.
Catheter Cardiovasc Interv ; 97(5): 959-961, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33001555

RESUMEN

High-risk transcatheter procedures requiring hemodynamic support are growing and require multiple vascular access that may be challenging in cases of peripheral artery disease or lack of radial access and exposure to a higher risk of vascular complications. We report the novel utilization of a Y-shaped arterial extracorporeal membrane oxygenation (ECMO) cannula used as a single femoral access to perform percutaneous coronary intervention (PCI) and aortography during high-risk transcatheter aortic valve replacement (TAVR). The utilization of this 2-in-1 ECMO cannula may simplify vascular access and reduce vascular and bleeding complications during high-risk ECMO-supported transcatheter procedures.


Asunto(s)
Estenosis de la Válvula Aórtica , Oxigenación por Membrana Extracorpórea , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/cirugía , Cánula , Oxigenación por Membrana Extracorpórea/efectos adversos , Arteria Femoral/diagnóstico por imagen , Humanos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA