Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 390(3): 212-220, 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38231622

RESUMEN

BACKGROUND: The Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT) showed a greater benefit with respect to mortality at 5 years among patients who received cardiac-resynchronization therapy (CRT) than among those who received implantable cardioverter-defibrillators (ICDs). However, the effect of CRT on long-term survival is not known. METHODS: We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more (or a paced QRS duration of 200 msec or more) to receive either an ICD alone or a CRT defibrillator (CRT-D). We assessed long-term outcomes among patients at the eight highest-enrolling participating sites. The primary outcome was death from any cause; the secondary outcome was a composite of death from any cause, heart transplantation, or implantation of a ventricular assist device. RESULTS: The trial enrolled 1798 patients, of whom 1050 were included in the long-term survival trial; the median duration of follow-up for the 1050 patients was 7.7 years (interquartile range, 3.9 to 12.8), and the median duration of follow-up for those who survived was 13.9 years (interquartile range, 12.8 to 15.7). Death occurred in 405 of 530 patients (76.4%) assigned to the ICD group and in 370 of 520 patients (71.2%) assigned to the CRT-D group. The time until death appeared to be longer for those assigned to receive a CRT-D than for those assigned to receive an ICD (acceleration factor, 0.80; 95% confidence interval, 0.69 to 0.92; P = 0.002). A secondary-outcome event occurred in 412 patients (77.7%) in the ICD group and in 392 (75.4%) in the CRT-D group. CONCLUSIONS: Among patients with a reduced ejection fraction, a widened QRS complex, and NYHA class II or III heart failure, the survival benefit associated with receipt of a CRT-D as compared with ICD appeared to be sustained during a median of nearly 14 years of follow-up. (RAFT ClinicalTrials.gov number, NCT00251251.).


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Estimación de Kaplan-Meier , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Electrocardiografía , Estudios de Seguimiento , Factores de Tiempo
2.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

3.
Lancet ; 402(10396): 118-128, 2023 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-37331368

RESUMEN

BACKGROUND: Etripamil is a fast-acting, intranasally administered calcium-channel blocker in development for on-demand therapy outside a health-care setting for paroxysmal supraventricular tachycardia. We aimed to evaluate the efficacy and safety of etripamil 70 mg nasal spray using a symptom-prompted, repeat-dose regimen for acute conversion of atrioventricular-nodal-dependent paroxysmal supraventricular tachycardia to sinus rhythm within 30 min. METHODS: RAPID was a multicentre, randomised, placebo-controlled, event-driven trial, conducted at 160 sites in North America and Europe as part 2 of the NODE-301 study. Eligible patients were aged at least 18 years and had a history of paroxysmal supraventricular tachycardia with sustained, symptomatic episodes (≥20 min) as documented by electrocardiogram. Patients were administered two test doses of intranasal etripamil (each 70 mg, 10 min apart) during sinus rhythm; those who tolerated the test doses were randomly assigned (1:1) using an interactive response technology system to receive either etripamil or placebo. Prompted by symptoms of paroxysmal supraventricular tachycardia, patients self-administered a first dose of intranasal 70 mg etripamil or placebo and, if symptoms persisted beyond 10 min, a repeat dose. Continuously recorded electrocardiographic data were adjudicated, by individuals masked to patient assignment, for the primary endpoint of time to conversion of paroxysmal supraventricular tachycardia to sinus rhythm for at least 30 s within 30 min after the first dose, which was measured in all patients who administered blinded study drug for a confirmed atrioventricular-nodal-dependent event. Safety outcomes were assessed in all patients who self-administered blinded study drug for an episode of perceived paroxysmal supraventricular tachycardia. This trial is registered at ClinicalTrials.gov, NCT03464019, and is complete. FINDINGS: Between Oct 13, 2020, and July 20, 2022, among 692 patients randomly assigned, 184 (99 from the etripamil group and 85 from the placebo group) self-administered study drug for atrioventricular-nodal-dependent paroxysmal supraventricular tachycardia, with diagnosis and timing confirmed. Kaplan-Meier estimates of conversion rates by 30 min were 64% (63/99) with etripamil and 31% (26/85) with placebo (hazard ratio 2·62; 95% CI 1·66-4·15; p<0·0001). Median time to conversion was 17·2 min (95% CI 13·4-26·5) with the etripamil regimen versus 53·5 min (38·7-87·3) with placebo. Prespecified sensitivity analyses of the primary assessment were conducted to test robustness, yielding supporting results. Treatment-emergent adverse events occurred in 68 (50%) of 99 patients treated with etripamil and 12 (11%) of 85 patients in the placebo group, most of which were located at the administration site and were mild or moderate, and all of which were transient and resolved without intervention. Adverse events occurring in at least 5% of patients treated with etripamil were nasal discomfort (23%), nasal congestion (13%), and rhinorrhea (9%). No serious etripamil-related adverse events or deaths were reported. INTERPRETATION: Using a symptom-prompted, self-administered, initial and optional-repeat-dosing regimen, intranasal etripamil was well tolerated, safe, and superior to placebo for the rapid conversion of atrioventricular-nodal-dependent paroxysmal supraventricular tachycardia to sinus rhythm. This approach could empower patients to treat paroxysmal supraventricular tachycardia themselves outside of a health-care setting, and has the potential to reduce the need for additional medical interventions, such as intravenous medications given in an acute-care setting. FUNDING: Milestone Pharmaceuticals.


Asunto(s)
Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Adolescente , Adulto , Taquicardia Supraventricular/tratamiento farmacológico , Taquicardia Paroxística/tratamiento farmacológico , Benzoatos/uso terapéutico , Método Doble Ciego
4.
Circulation ; 145(10): 742-753, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-34913361

RESUMEN

BACKGROUND: Regulatory authorities of most industrialized countries recommend 6 months of private driving restriction after implantation of a secondary prevention implantable cardioverter-defibrillator (ICD). These driving restrictions result in significant inconvenience and social implications. This study aimed to assess the incidence rate of appropriate device therapies in contemporary recipients of a secondary prevention ICD. METHODS: This retrospective study at 3 Canadian tertiary care centers enrolled consecutive patients with new secondary prevention ICD implants between 2016 and 2020. RESULTS: For a median of 760 days (324, 1190 days), 721 patients were followed up. The risk of recurrent ventricular arrhythmia was highest during the first 3 months after device insertion (34.4%) and decreased over time (10.6% between 3 and 6 months, 11.7% between 6 and 12 months). The corresponding incidence rate per 100 patient-days was 0.48 (95% CI, 0.35-0.64) at 90 days, 0.28 (95% CI, 0.17-0.45) at 180 days, and 0.21 (95% CI, 0.13-0.33) between 181 and 365 days after ICD insertion (P<0.001). The cumulative incidence of arrhythmic syncope resulting in sudden cardiac incapacitation was 1.8% within the first 90 days and subsequently dropped to 0.4% between 91 and 180 days (P<0.001) after ICD insertion. CONCLUSIONS: The incidence rate of appropriate therapies resulting in sudden cardiac incapacitation in contemporary recipients of a secondary prevention ICD is much lower than previously reported and declines significantly after the first 3 months. Lowering driving restrictions to 3 months after the index cardiac event seems safe, and revision of existing guidelines should be considered in countries still adhering to a 6-month period. Existing restrictions for private driving after implantation of a secondary prevention ICD should be reconsidered.


Asunto(s)
Desfibriladores Implantables , Canadá , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Humanos , Prevención Primaria/métodos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
5.
N Engl J Med ; 382(19): 1823-1831, 2020 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-32374963

RESUMEN

BACKGROUND: Access to pacemakers and defibrillators is problematic in places with limited resources. Resterilization and reuse of implantable cardiac devices obtained post mortem from patients in wealthier nations have been undertaken, but uncertainty around the risk of infection is a concern. METHODS: A multinational program was initiated in 1983 to provide tested and resterilized pacemakers and defibrillators to underserved nations; a prospective registry was established in 2003. Patients who received reused devices in this program were matched in a 1:3 ratio with control patients who received new devices implanted in Canada. The primary outcome was infection or device-related death, with mortality from other causes modeled as a competing risk. RESULTS: Resterilized devices were implanted in 1051 patients (mean [±SD] age, 63.2±18.5 years; 43.6% women) in Mexico (36.0%), the Dominican Republic (28.1%), Guatemala (26.6%), and Honduras (9.3%). Overall, 85% received pacemakers and 15% received defibrillators, with one (55.5%), two (38.8%), or three (5.7%) leads. Baseline characteristics did not differ between these patients and the 3153 matched control patients. At 2 years of follow-up, infections had occurred in 21 patients (2.0%) with reused devices and in 38 (1.2%) with new devices (hazard ratio, 1.66; 95% confidence interval, 0.97 to 2.83; P = 0.06); there were no device-related deaths. The most common implicated pathogens were Staphylococcus aureus and S. epidermidis. CONCLUSIONS: Among patients in underserved countries who received a resterilized and reused pacemaker or defibrillator, the incidence of infection or device-related death at 2 years was 2.0%, an incidence that did not differ significantly from that seen among matched control patients with new devices in Canada.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Equipo Reutilizado , Infecciones/etiología , Marcapaso Artificial/efectos adversos , Adulto , Anciano , Estudios de Casos y Controles , Países en Desarrollo , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Infecciones/epidemiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Mortalidad , Factores de Riesgo , Esterilización
6.
Catheter Cardiovasc Interv ; 101(1): 227-230, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36413620

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) has emerged over the last two decades as an efficient and safe alternative to oral anticoagulation for stroke prevention. However, LAAO remains challenging due to the variety of anatomies and the multiple steps required to complete the procedure. AIMS: We report the first series of in-human experience of the new all-in-one VersaCross Connect system designed to access the left atrium in conjunction with the delivery sheath for deployment of the WATCHMAN FLX device. METHODS: We prospectively included the first nine consecutive cases of LAAO using the new VersaCross Connect system for WATCHMAN FLX device implantation at the Montreal Heart Institute and Vancouver General Hospital and collected procedural duration (defined as time from femoral access to closure) and time from transseptal puncture to device delivery. RESULTS: VersaCross Connect system use for WATCHMAN FLX implantation was successful in all patients. No procedural complication was reported. Mean procedural time was 31 ± 6.3 min with a fluoroscopy time of 6.7 ± 4.9 min. The mean delay between the transseptal puncture and device implantation was 12.2 ± 1.9 min. CONCLUSIONS: We showed that the VersaCross Connect system was safe and successfully used in all first nine cases. This new system helped improve the efficiency of the procedure.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Resultado del Tratamiento , Atrios Cardíacos , Cateterismo Cardíaco , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
7.
Ann Intern Med ; 175(12): 1658-1665, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36343346

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICDs) improve survival in patients at risk for cardiac arrest, but are associated with intravascular lead-related complications. The subcutaneous ICD (S-ICD), with no intravascular components, was developed to minimize lead-related complications. OBJECTIVE: To assess key ICD performance measures related to delivery of ICD therapy, including inappropriate ICD shocks (delivered in absence of life-threatening arrhythmia) and failed ICD shocks (which did not terminate ventricular arrhythmia). DESIGN: Randomized, multicenter trial. (ClinicalTrials.gov: NCT02881255). SETTING: The ATLAS trial. PATIENTS: 544 eligible patients (141 female) with a primary or secondary prevention indication for an ICD who were younger than age 60 years, had a cardiogenetic phenotype, or had prespecified risk factors for lead complications were electrocardiographically screened and 503 randomly assigned to S-ICD (251 patients) or transvenous ICD (TV-ICD) (252 patients). Mean follow-up was 2.5 years (SD, 1.1). Mean age was 49.0 years (SD, 11.5). MEASUREMENTS: The primary outcome was perioperative major lead-related complications. RESULTS: There was a statistically significant reduction in perioperative, lead-related complications, which occurred in 1 patient (0.4%) with an S-ICD and in 12 patients (4.8%) with TV-ICD (-4.4%; 95% CI, -6.9 to -1.9; P = 0.001). There was a trend for more inappropriate shocks with the S-ICD (hazard ratio [HR], 2.37; 95% CI, 0.98 to 5.77), but no increase in failed appropriate ICD shocks (HR, 0.61 (0.15 to 2.57). Patients in the S-ICD group had more ICD site pain, measured on a 10-point numeric rating scale, on the day of implant (4.2 ± 2.8 vs. 2.9 ± 2.2; P < 0.001) and 1 month later (1.3 ± 1.8 vs. 0.9 ± 1.5; P = 0.035). LIMITATION: At present, the ATLAS trial is underpowered to detect differences in clinical shock outcomes; however, extended follow-up is ongoing. CONCLUSION: The S-ICD reduces perioperative, lead-related complications without significantly compromising the effectiveness of ICD shocks, but with more early postoperative pain and a trend for more inappropriate shocks. PRIMARY FUNDING SOURCE: Boston Scientific.


Asunto(s)
Desfibriladores Implantables , Paro Cardíaco , Femenino , Humanos , Desfibriladores Implantables/efectos adversos , Resultado del Tratamiento , Arritmias Cardíacas , Factores de Riesgo , Muerte Súbita Cardíaca/etiología
8.
Eur Heart J ; 43(22): 2103-2115, 2022 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-35302168

RESUMEN

Sudden cardiac death (SCD) accounts for up to 25% of deaths in patients with congenital heart disease (CHD). To date, research has largely been driven by observational studies and real-world experience. Drawbacks include varying definitions, incomplete taxonomy that considers SCD as a unitary diagnosis as opposed to a terminal event with diverse causes, inconsistent outcome ascertainment, and limited data granularity. Notwithstanding these constraints, identified higher-risk substrates include tetralogy of Fallot, transposition of the great arteries, cyanotic heart disease, Ebstein anomaly, and Fontan circulation. Without autopsies, it is often impossible to distinguish SCD from non-cardiac sudden deaths. Asystole and pulseless electrical activity account for a high proportion of SCDs, particularly in patients with heart failure. High-quality cardiopulmonary resuscitation is essential to improve outcomes. Pulmonary hypertension and CHD complexity are associated with lower likelihood of successful resuscitation. Risk stratification for primary prevention implantable cardioverter-defibrillators (ICDs) should consider the probability of SCD due to a shockable rhythm, competing causes of mortality, complications of ICD therapy, and associated costs. Risk scores to better estimate probabilities of SCD and CHD-specific guidelines and consensus-based recommendations have been proposed. The subcutaneous ICD has emerged as an attractive alternative to transvenous systems in those with vascular access limitations, prior device infections, intra-cardiac shunts, or a Fontan circulation. Further improving SCD-related outcomes will require a multidimensional approach to research that addresses disease processes and triggers, taxonomy to better reflect underlying pathophysiology, high-risk features, early warning signs, access to high-quality cardiopulmonary resuscitation and specialized care, and preventive therapies tailored to underlying mechanisms.


Asunto(s)
Desfibriladores Implantables , Procedimiento de Fontan , Paro Cardíaco , Cardiopatías Congénitas , Transposición de los Grandes Vasos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Procedimiento de Fontan/efectos adversos , Cardiopatías Congénitas/terapia , Humanos , Factores de Riesgo
9.
Can Assoc Radiol J ; 72(4): 814-830, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33231493

RESUMEN

Magnetic resonance imaging (MRI) is a unique and powerful diagnostic tool that provides images without ionizing radiation and, at times, can be the only modality to properly assess and diagnose some pathologies. Although many patients will need an MRI in their lifetime, many of them are still being unjustly denied access to it due to what were once considered absolute contraindications, including MR nonconditional pacemakers and implantable cardioverter-defibrillators. However, there are a number of large studies that have recently demonstrated that MRI can safely be performed in these patients under certain conditions. In addition, there are an increasing number of novel cardiac devices implanted in patients who may require an MRI. Radiologists need to familiarize themselves with these devices, identify which patients with these devices can safely undergo MRI, and under which conditions. In this article, we will review the current literature on MR safety and cardiac devices, elaborate on how to safely image patients with cardiac devices, and share the expertise of our tertiary cardiac institute.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/métodos , Marcapaso Artificial/efectos adversos , Seguridad del Paciente , Guías de Práctica Clínica como Asunto , Artefactos , Humanos , Radiólogos
11.
Am Heart J ; 207: 1-9, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30399474

RESUMEN

BACKGROUND: The defibrillator lead is the weakest part of the transvenous (TV) implantable cardioverter defibrillation (ICD) system and a frequent cause of morbidity. Lead dislodgement, cardiac perforation, insertion-related trauma including pneumothorax and vascular injury, are common early complications of TV-ICD implantation. Venous occlusion, tricuspid valve dysfunction, lead fracture and lead insulation failure are additional, later complications. The introduction of a totally sub-cutaneous ICD (S-ICD) may reduce these lead-related issues, patient morbidity, hospitalizations and costs. However, such benefits compared to the TV-ICD have not been demonstrated in a randomized trial. DESIGN: ATLAS (Avoid Transvenous Leads in Appropriate Subjects) is a multi-centered, randomized, open-label, parallel group trial. Patients younger than 60 years are eligible. If older than 60 years, patients are eligible if they have an inherited heart rhythm disease, or risk factors for ICD-related complication, such as hemodialysis, a history of ICD or pacemaker infection, heart valve replacement, or severe pulmonary disease. This study will determine if using an S-ICD compared to a TV-ICD reduces a primary composite outcome of perioperative complications including pulmonary or pericardial perforation, lead dislodgement or dysfunction, tricuspid regurgitation and ipsilateral venous thrombosis. Five hundred patients will be enrolled from 14 Canadian hospitals, and data collected to both early- (at 6 months) and mid-term complications (at 24 months) as well as mortality and ICD shock efficacy. SUMMARY: The ATLAS randomized trial is comparing early- and mid-term vascular and lead-related complications among S-ICD versus TV-ICD recipients who are younger or at higher risk of ICD-related complications.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Falla de Equipo , Selección de Paciente , Complicaciones Posoperatorias/prevención & control , Adulto , Comités Consultivos , Factores de Edad , Canadá , Diseño de Equipo , Humanos , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Proyectos de Investigación , Factores de Riesgo , Adulto Joven
12.
Curr Heart Fail Rep ; 16(6): 229-239, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31768918

RESUMEN

PURPOSE OF REVIEW: While use of implantable cardioverter defibrillator (ICD) in patients with heart failure (HF) and reduced ejection fraction is recommended, their role in patients with left ventricular assist device (LVAD) remains controversial, especially with continuous flow (CF) devices. RECENT FINDINGS: Ventricular arrhythmias (VA) in LVAD patients are frequent and associated with worse outcomes, especially postoperatively. Data on the role of ICDs in LVAD patients are scarce, based on case reports or small retrospective series. While the majority of LVAD patients currently have an ICD, it seems that some might not derive any benefit, with additional risks in terms of inappropriate shocks, psychological distress, and infections. Some CF-LVAD patients are at high risk of VA and hemodynamic collapse; under those circumstances, an ICD might provide benefits. A randomized-controlled trial of routine ICD implantation in CF-LVAD would be needed to clarify their impact on survival in low risk patients.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Arritmias Cardíacas/etiología , Desfibriladores Implantables/efectos adversos , Diseño de Equipo , Humanos , Factores de Riesgo
13.
J Cardiovasc Electrophysiol ; 29(2): 308-315, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29064134

RESUMEN

INTRODUCTION: Expert societies recently published strong recommendations to reduce the exposure of patients and staff to ionizing radiation (IR) during interventional and electrophysiology (EP) procedures. However, adherence to these guidelines remains difficult and the impact of implementing such recommendations is poorly characterized. METHODS AND RESULTS: We conducted a single-center cohort study to quantify radiation exposure over time in three EP laboratories at the Montreal Heart Institute during 5,546 consecutive procedures from 2012 to 2015 by 11 primary operators. Overall, 2,618 (47.2%) procedures were catheter-based and 2,928 (52.8%) were device interventions. Interventions to reduce radiation exposure included educational initiatives to raise awareness (i.e., limiting cine acquisition, patient position, table height), slower frame rate, lower radiation dose per pulse, collimation, and integration with 3-D mapping systems and/or MediGuide technology. An 85% reduction in IR exposure was observed from 2012 to 2015, with the mean dose-area-product (DAP) decreasing from 7.65 ± 0.05 Gy·cm2 to 1.15 ± 0.04 Gy·cm2 (P < 0.001). This was true for catheter-based procedures (mean DAP 16.99 ± 0.08 to 2.00 ± 0.06 Gy·cm2 , P < 0.001) and device interventions (mean DAP 4.18 ± 0.06 to 0.64 ± 0.05 Gy·cm2 , P < 0.001). The median effective dose of IR recorded per quarter by 282 cervical dosimeters on EP staff decreased from 0.57 (IQR 0.18, 1.03) mSv in 2012 to 0.00 (IQR 0.00, 0.19) mSv in 2015, P < 0.001. CONCLUSION: Enforcing good clinical practices with simple measures and low-dose fluoroscopy settings are highly effective in reducing IR exposure in the EP lab. These promising results should encourage other EP labs to adopt similar protective measures.


Asunto(s)
Cateterismo Cardíaco/métodos , Técnicas Electrofisiológicas Cardíacas , Exposición Profesional/prevención & control , Implantación de Prótesis/métodos , Dosis de Radiación , Exposición a la Radiación/prevención & control , Radiografía Intervencional/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Técnicas Electrofisiológicas Cardíacas/efectos adversos , Humanos , Exposición Profesional/efectos adversos , Salud Laboral , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Factores Protectores , Exposición a la Radiación/efectos adversos , Protección Radiológica , Radiografía Intervencional/efectos adversos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
14.
Europace ; 20(FI2): f240-f248, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29771327

RESUMEN

Aims: Comparison of outcomes between subcutaneous and transvenous implantable cardioverter-defibrillator (S-ICD and TV-ICD) therapy is hampered by varying patient characteristics and complication definitions. The aim of this analysis is to compare clinical outcomes of S-ICD and TV-ICD therapy in a matched cohort. Methods and results: Patients implanted with de novo implantable cardioverter-defibrillators without need for pacing were selected from two studies: SIMPLE (n = 1091 single and n = 553 dual chamber TV-ICDs) and EFFORTLESS (n = 798 S-ICDs). Subcutaneous implantable cardioverter-defibrillator patients were 1:1 matched on propensity score to TV-ICD patients. Propensity scores were calculated using 15 baseline characteristics including diagnosis. The Kaplan-Meier estimates for complications requiring invasive intervention, appropriate shocks, and inappropriate shocks were calculated at 3 years follow-up. The primary analysis yielded 391 patients pairs with balanced baseline characteristics, with mean age 55 ± 14 years, 49% ischaemic cardiomyopathy, mean left ventricular ejection fraction 40%, 71% primary prevention, and 89% of TV-ICDs were single chamber. Follow-up was mean 2.9 years in the S-ICD arm vs. 3.3 in the TV-ICD arm. All-cause complications occurred in 9.0% of S-ICD vs. 6.5% of TV-ICD patients, P = 0.29. Appropriate shocks occurred in 9.9% of S-ICD vs. 13.8% in TV-ICD patients, P = 0.03 and inappropriate shocks in 11.9% in S-ICD vs. 8.9% in TV-ICD patients (P = 0.07). Total shock burden (20 vs. 31, P = 0.05) and appropriate shock burden per 100 patients years (9 vs. 18, P = 0.02) were lower for S-ICD patients, while inappropriate shock burden was equal (11 vs. 13, P = 0.56). Conclusion: The earliest experience of the S-ICD demonstrates similar outcomes as contemporary TV-ICD therapy in a matched comparison with predominately single-chamber devices at 3 years follow-up.


Asunto(s)
Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Implantación de Prótesis/métodos , Adulto , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Muerte Súbita Cardíaca/epidemiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Estudios Observacionales como Asunto , Puntaje de Propensión , Implantación de Prótesis/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
J Cardiovasc Electrophysiol ; 28(5): 559-563, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28233925

RESUMEN

INTRODUCTION: The standard 4-minute application time for transcatheter cryoablation was determined in the 1990s when the system employed less potent chlorofluorocarbon refrigerants. The current refrigerant, nitrous oxide, generates substantially colder temperatures, with a faster cooling rate. METHODS AND RESULTS: We conducted a preclinical study on 32 mongrel dogs with stratified randomization of right atrial, right ventricular, and left ventricular chambers to 2-minute versus 4-minute application times using 8-mm electrode tip cryocatheters (Freezor Max, Medtronic CryoCath LP, Montreal, Canada). Animals were sacrificed one month after the procedure. Three-dimensional morphometric analyses were conducted in a blinded fashion. A total of 193 identified ablation lesions were processed for histological analyses, 102 with 2-minute applications and 91 with 4-minute applications. Ablation lesion surface area (167.8 ± 21.6 mm2 vs. 194.3 ± 22.6 mm2 , P = 0.40), maximum depth (4.4 ± 0.2 mm vs. 4.5 ± 0.2 mm, P = 0.71), and volume (125.7 ± 69.5 mm3 vs. 141.0 ± 83.5 mm3 , P = 0.25) were similar between groups. Overall, 90.2% of ablation lesions in the right atrium were transmural, 45.6% in the right ventricle, and 2.4% in the left ventricle, with no differences between 2-minute and 4-minute application times (P = 0.55). Thrombus was detected on the endocardial surface of 0.0% and 3.3% of ablation lesions created with 2-minute and 4-minute application times, respectively (P = 0.10). CONCLUSION: Single 2-minute and 4-minute application times result in catheter ablation lesions of similar size using the modern cryoablation system with nitrous oxide as a refrigerant. While these findings suggest the potential to reduce the standard 4-minute application time, further studies are required to compare clinical efficacy.


Asunto(s)
Cateterismo Cardíaco/métodos , Frío , Criocirugía/métodos , Atrios Cardíacos/cirugía , Ventrículos Cardíacos/cirugía , Óxido Nitroso/farmacología , Animales , Perros , Atrios Cardíacos/patología , Ventrículos Cardíacos/patología , Modelos Animales , Factores de Tiempo
16.
Europace ; 19(6): 1043-1048, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27377075

RESUMEN

AIMS: It remains unknown whether contact force (CF) sensing technology is of value for cavotricuspid isthmus (CTI) ablation. We prospectively evaluated procedural parameters and outcomes of CF-guided vs. CF-blinded CTI ablation for typical atrial flutter (AFL). METHODS AND RESULTS: A total of 70 consecutive patients (62.5 ± 10.9 years) undergoing CTI ablation for AFL were prospectively enrolled, 35 in CF-blinded and 35 in CF-guided groups. A CF-sensing catheter (power 25-35 W) was used in all. In the CF-guided group, CF target range was 10-25 g, whereas in the CF-blinded group, the operator was blinded to CF. The isthmus was divided into anterior, middle, and posterior segments for region-specific CF analysis. The procedural endpoint of bidirectional isthmus block following a 20-min observation period was achieved in all. A trend towards lower fluoroscopy and procedure duration was observed when the CF-guided group was compared with the CF-blinded group. The total radiofrequency (RF) energy delivery time required to achieve bidirectional block was significantly lower in the CF-guided vs. CF-blinded group [10.0 min (IQR 8.3;15.1) vs. 15.9 min (IQR 9.6;24.7), P= 0.0020], with a significant inverse correlation between CF and total RF delivery time (r = -0.36; P= 0.0027). Mean CF measurements significantly increased from anterior to posterior anatomical zones of CTI in the CF-blinded group (ANOVA P= 0.0466). CONCLUSIONS: Catheter ablation of AFL guided by real-time CF assessment results in a significant reduction in total RF delivery time. Real-time CF measurements facilitate the maintenance of homogenous efficient contact all along the CTI, particularly in the anterior segment where CF is generally lower.


Asunto(s)
Aleteo Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Transductores de Presión , Potenciales de Acción , Anciano , Análisis de Varianza , Aleteo Atrial/diagnóstico , Aleteo Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Distribución de Chi-Cuadrado , Diseño de Equipo , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
J Cardiovasc Electrophysiol ; 27(11): 1337-1343, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27458078

RESUMEN

INTRODUCTION: Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in substantial ionizing radiation (IR) exposure to the patient and operator. We assessed the impact of lower-dose fluoroscopy settings and a sensor-based electromagnetic tracking system (MediGuide™, MDG) on reducing IR exposure during CRT implantation. METHODS: A single-center 2-group cohort study was conducted on 348 consecutive patients, age 66.4 ± 11.0 years, 80.4% male, with CRT implant procedures from 2013 to 2015. Patients were arbitrarily assigned to MDG (N = 239) versus no MDG (N = 109) guidance. Lower-dose fluoroscopy settings were adopted in January 2015 (3 instead of 6 fps; 23 instead of 40 nGy/pulse; N = 101). RESULTS: Overall, MDG was associated with an 82.1% reduction in IR exposure (393 µGray·m2 vs. 2191 µGray·m2 , P < 0.001). Lower-dose fluoroscopy resulted in a 59.5% reduction in IR-exposure without MDG (1055 µGray·m2 vs. 2608 µGray·m2 , P < 0.001) and 81.8% reduction with MDG (108 µGray·m2 vs. 595 µGray·m2 , P < 0.001). Low-dose fluoroscopy combined with MDG was associated with a 95.9% lower exposure to IR when compared to standard fluoroscopy without MDG (108 µGray·m2 vs. 2608 µGray·m2 , P < 0.001). Procedures with MDG were shorter (96 minutes vs. 123 minutes, P < 0.001) and associated with a trend towards a higher success rate (94.6% vs. 89.0%, P = 0.062), with fewer coronary sinus cannulation failures (2.1% vs. 6.4%, P = 0.040). CONCLUSION: Low-dose fluoroscopy settings are highly effective (>50%) in reducing IR exposure during CRT implant procedures. When combined with MDG, >95% reduction in IR exposure is achieved. Moreover, MDG shortens procedural duration and may improve acute procedural outcomes.

18.
Pacing Clin Electrophysiol ; 38(1): 63-70, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25311868

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in significant ionizing radiation (IR) exposure to the patient and operator. We report our early experience working with a novel sensor-based electromagnetic tracking system (MediGuide™, MDG, St. Jude Medical Inc., St. Paul, MN, USA), in terms of procedural IR exposure reduction. METHODS AND RESULTS: Information regarding patient demographics, procedural details, procedural duration, and IR exposure were prospectively collected on 130 consecutive CRT procedures performed between January 2013 and January 2014. Sixty procedures were performed with MDG guidance, and 70 were performed without MDG guidance. Despite a nonsignificant trend toward shorter procedure duration with the use of MDG (120 minutes vs 138 minutes with non-MDG, P = 0.088), a 66% reduction in total IR exposure (median 769 µGray · m(2) vs 2,608 µGray · m(2), P < 0.001) was found. This reduction was primarily driven by a >90% reduction in IR dose required to cannulate the coronary sinus (median 80 µGray · m(2) vs 922 µGray · m(2), P < 0.001), and to a lesser extent from a reduction in IR dose required for LV lead placement (median 330 µGray·m(2) vs 737 µGray · m(2), P = 0.059). In addition, a significant learning curve effect was observed with a significantly shorter procedural duration for the last 15 cases compared to the first 15 cases (median 98 minutes vs 175 minutes, P < 0.001). CONCLUSION: The nonfluoroscopic MDG positioning system is associated with a dramatic reduction in exposure to IR during CRT implant procedures, with a 90% decrease in the IR dose required to cannulate the coronary sinus. A steep learning curve was quantified.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Implantación de Prótesis/métodos , Traumatismos por Radiación/prevención & control , Anciano , Radiación Electromagnética , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Cirugía Asistida por Computador
19.
Pacing Clin Electrophysiol ; 38(7): 784-90, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25682843

RESUMEN

BACKGROUND: Fluoroscopic guidance is used to position catheters during cardiac ablation. We evaluated the impact of a novel nonfluoroscopic sensor-guided electromagnetic navigation system (MG) on radiation exposure during catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL). METHODS: A total of 134 consecutive patients referred for ablation of AF (n = 44) or AFL (n = 90) ablation were prospectively enrolled. In one group the MG system was used for nonfluoroscopic catheter positioning, whereas in the conventional group standard fluoroscopy was utilized. Fluoroscopy times were assessed for each stage of procedure and total radiation exposure was quantified. RESULTS: Patient characteristics were similar between the groups. The procedural end point was achieved in all. Median (interquartile range [IQR]) fluoroscopy times were 12.5 minutes (7.6, 17.4) MG group versus 21.5 minutes (15.3, 23.0) conventional group (P < 0.0001) for AF ablation, and 0.8 minutes (0.4, 2.5) MG group versus 9.9 minutes (5.1, 22.5) conventional group (P < 0.0001) for AFL ablation. Median (IQR) total radiation exposure (µGy·m(2)) was 1,107 (906, 2,033) MG group versus 2,835 (1,688, 3,855) conventional group (P = 0.0001) for AF ablation, and 161 (65, 537) MG group versus 1,651 (796, 4,569) conventional group (P < 0.0001) for AFL ablation. No difference in total procedural time was seen. CONCLUSIONS: The use of a novel nonfluoroscopic catheter tracking system is associated with a significant reduction in radiation exposure during AF and AFL ablation (61% and 90% reduction, respectively). In the era of heightened awareness of the importance of radiation reduction, this system represents a safe and efficient tool to decrease radiation exposure during electrophysiological ablation procedures.


Asunto(s)
Fibrilación Atrial/cirugía , Aleteo Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/métodos , Exposición a la Radiación/análisis , Radiografía Intervencional/instrumentación , Fibrilación Atrial/diagnóstico por imagen , Aleteo Atrial/diagnóstico por imagen , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Dosis de Radiación , Protección Radiológica , Radiografía Intervencional/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
20.
Curr Opin Cardiol ; 29(1): 45-52, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24284978

RESUMEN

PURPOSE OF REVIEW: Sudden cardiac death is a leading cause of mortality in patients with congenital heart disease (CHD), such that implantable cardioverter-defibrillators (ICDs) are a critical component of care. Objectives of this review are to highlight recent advances regarding ICDs in CHD, with a focus on clinical indications, technical issues and solutions, and patient outcomes. RECENT FINDING: Evolving ICD indications in CHD are primarily derived from observational research or extrapolations from the general adult literature. Technical challenges to device implantation include obstructed vasculature or conduits, intracardiac shunts with their attendant risk for systemic thromboemboli, and lack of venous access to the heart. In selected patients, tailored epicardial systems may be considered that include subcutaneous, retrocardiac, and/or venous (e.g., azygous) coils. Alternatively, an entirely subcutaneous ICD may be a reasonable option in patients with no bradycardia or antitachycardia pacing indications. Long-term complications include inappropriate shocks, lead failure, reduction in quality of life, shock-related anxiety, and impaired sexual function. SUMMARY: Although ICDs undeniably save lives, challenges to applying this technology to patients with CHD include the paucity of evidence-based data to guide patient selection, technical challenges related to venous access, patient size, anatomic complexities, and a high rate of complications.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardiopatías Congénitas/terapia , Muerte Súbita Cardíaca/etiología , Cardiopatías Congénitas/complicaciones , Humanos , Selección de Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA