Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Magn Reson Med ; 89(2): 577-593, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36161727

RESUMEN

PURPOSE: To develop and validate a method for B 0 $$ {B}_0 $$ mapping for knee imaging using the quantitative Double-Echo in Steady-State (qDESS) exploiting the phase difference ( Δ Î¸ $$ \Delta \theta $$ ) between the two echoes acquired. Contrary to a two-gradient-echo (2-GRE) method, Δ Î¸ $$ \Delta \theta $$ depends only on the first echo time. METHODS: Bloch simulations were applied to investigate robustness to noise of the proposed methodology and all imaging studies were validated with phantoms and in vivo simultaneous bilateral knee acquisitions. Two phantoms and five healthy subjects were scanned using qDESS, water saturation shift referencing (WASSR), and multi-GRE sequences. Δ B 0 $$ \Delta {B}_0 $$ maps were calculated with the qDESS and the 2-GRE methods and compared against those obtained with WASSR. The comparison was quantitatively assessed exploiting pixel-wise difference maps, Bland-Altman (BA) analysis, and Lin's concordance coefficient ( ρ c $$ {\rho}_c $$ ). For in vivo subjects, the comparison was assessed in cartilage using average values in six subregions. RESULTS: The proposed method for measuring Δ B 0 $$ \Delta {B}_0 $$ inhomogeneities from a qDESS acquisition provided Δ B 0 $$ \Delta {B}_0 $$ maps that were in good agreement with those obtained using WASSR. Δ B 0 $$ \Delta {B}_0 $$ ρ c $$ {\rho}_c $$ values were ≥ $$ \ge $$ 0.98 and 0.90 in phantoms and in vivo, respectively. The agreement between qDESS and WASSR was comparable to that of a 2-GRE method. CONCLUSION: The proposed method may allow B0 correction for qDESS T 2 $$ {T}_2 $$ mapping using an inherently co-registered Δ B 0 $$ \Delta {B}_0 $$ map without requiring an additional B0 measurement sequence. More generally, the method may help shorten knee imaging protocols that require an auxiliary Δ B 0 $$ \Delta {B}_0 $$ map by exploiting a qDESS acquisition that also provides T 2 $$ {T}_2 $$ measurements and high-quality morphological imaging.


Asunto(s)
Rodilla , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Rodilla/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Agua
2.
J Magn Reson Imaging ; 58(3): 951-962, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36583628

RESUMEN

BACKGROUND: Diffusion-weighted imaging (DWI) may allow for breast cancer screening MRI without a contrast injection. Multishot methods improve prone DWI of the breasts but face different challenges in the supine position. PURPOSE: To establish a multishot DWI (msDWI) protocol for supine breast MRI and to evaluate the performance of supine vs. prone msDWI. STUDY TYPE: Prospective. POPULATION: Protocol optimization: 10 healthy women (ages 22-56), supine vs. prone: 24 healthy women (ages 22-62) and five women (ages 29-61) with breast tumors. FIELD STRENGTH/SEQUENCE: 3-T, protocol optimization msDWI: free-breathing (FB) 2-shots, FB 4-shots, respiratory-triggered (RT) 2-shots, RT 4-shots, supine vs. prone: RT 4-shot msDWI, T2-weighted fast-spin echo. ASSESSMENT: Protocol optimization and supine vs. prone: three observers performed an image quality assessment of sharpness, aliasing, distortion (vs. T2), perceived SNR, and overall image quality (scale of 1-5). Apparent diffusion coefficients (ADCs) in fibroglandular tissue (FGT) and breast tumors were measured. STATISTICAL TESTS: Effect of study variables on dichotomized ratings (4/5 vs. 1/2/3) and FGT ADCs were assessed with mixed-effects logistic regression. Interobserver agreement utilized Gwet's agreement coefficient (AC). Lesion ADCs were assessed by Bland-Altman analysis and concordance correlation (ρc ). P value <0.05 was considered statistically significant. RESULTS: Protocol optimization: 4-shots significantly improved sharpness and distortion; RT significantly improved sharpness, aliasing, perceived SNR, and overall image quality. FGT ADCs were not significantly different between shots (P = 0.812), FB vs. RT (P = 0.591), or side (P = 0.574). Supine vs. prone: supine images were rated significantly higher for sharpness, aliasing, and overall image quality. FGT ADCs were significantly higher supine; lesion ADCs were highly correlated (ρc  = 0.92). DATA CONCLUSION: Based on image quality, supine msDWI outperformed prone msDWI. Lesion ADCs were highly correlated between the two positions, while FGT ADCs were higher in the supine position. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Neoplasias de la Mama , Imagen de Difusión por Resonancia Magnética , Humanos , Femenino , Estudios Prospectivos , Posición Prona , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Neoplasias de la Mama/diagnóstico por imagen , Imagen Eco-Planar/métodos
3.
Magn Reson Med ; 85(2): 709-720, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32783339

RESUMEN

PURPOSE: To accelerate and improve multishot diffusion-weighted MRI reconstruction using deep learning. METHODS: An unrolled pipeline containing recurrences of model-based gradient updates and neural networks was introduced for accelerating multishot DWI reconstruction with shot-to-shot phase correction. The network was trained to predict results of jointly reconstructed multidirection data using single-direction data as input. In vivo brain and breast experiments were performed for evaluation. RESULTS: The proposed method achieves a reconstruction time of 0.1 second per image, over 100-fold faster than a shot locally low-rank reconstruction. The resultant image quality is comparable to the target from the joint reconstruction with a peak signal-to-noise ratio of 35.3 dB, a normalized root-mean-square error of 0.0177, and a structural similarity index of 0.944. The proposed method also improves upon the locally low-rank reconstruction (2.9 dB higher peak signal-to-noise ratio, 29% lower normalized root-mean-square error, and 0.037 higher structural similarity index). With training data from the brain, this method also generalizes well to breast diffusion-weighted imaging, and fine-tuning further reduces aliasing artifacts. CONCLUSION: A proposed data-driven approach enables almost real-time reconstruction with improved image quality, which improves the feasibility of multishot DWI in a wide range of clinical and neuroscientific studies.


Asunto(s)
Algoritmos , Imagen de Difusión por Resonancia Magnética , Artefactos , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Reproducibilidad de los Resultados
4.
J Magn Reson Imaging ; 53(5): 1594-1605, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33382171

RESUMEN

The image quality limitations of echo-planar diffusion-weighted imaging (DWI) are an obstacle to its widespread adoption in the breast. Steady-state DWI is an alternative DWI method with more robust image quality but its contrast for imaging breast cancer is not well-understood. The aim of this study was to develop and evaluate diffusion-weighted double-echo steady-state imaging with a three-dimensional cones trajectory (DW-DESS-Cones) as an alternative to conventional DWI for non-contrast-enhanced MRI in the breast. This prospective study included 28 women undergoing clinically indicated breast MRI and six asymptomatic volunteers. In vivo studies were performed at 3 T and included DW-DESS-Cones, DW-DESS-Cartesian, DWI, and CE-MRI acquisitions. Phantom experiments (diffusion phantom, High Precision Devices) and simulations were performed to establish framework for contrast of DW-DESS-Cones in comparison to DWI in the breast. Motion artifacts of DW-DESS-Cones were measured with artifact-to-noise ratio in volunteers and patients. Lesion-to-fibroglandular tissue signal ratios were measured, lesions were categorized as hyperintense or hypointense, and an image quality observer study was performed in DW-DESS-Cones and DWI in patients. Effect of DW-DESS-Cones method on motion artifacts was tested by mixed-effects generalized linear model. Effect of DW-DESS-Cones on signal in phantom was tested by quadratic regression. Correlation was calculated between DW-DESS-Cones and DWI lesion-to-fibroglandular tissue signal ratios. Inter-observer agreement was assessed with Gwet's AC. Simulations predicted hyperintensity of lesions with DW-DESS-Cones but at a 3% to 67% lower degree than with DWI. Motion artifacts were reduced with DW-DESS-Cones versus DW-DESS-Cartesian (p < 0.05). Lesion-to-fibroglandular tissue signal ratios were not correlated between DW-DESS-Cones and DWI (r = 0.25, p = 0.38). Concordant hyperintensity/hypointensity was observed between DW-DESS-Cones and DWI in 11/14 lesions. DW-DESS-Cones improved sharpness, distortion, and overall image quality versus DWI. DW-DESS-Cones may be able to eliminate motion artifacts in the breast allowing for investigation of higher degrees of steady-state diffusion weighting. Malignant breast lesions in DW-DESS-Cones demonstrated hyperintensity with respect to surrounding tissue without an injection of contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Neoplasias de la Mama , Imagen de Difusión por Resonancia Magnética , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Imagen Eco-Planar , Femenino , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos
5.
J Magn Reson Imaging ; 53(3): 807-817, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33067849

RESUMEN

BACKGROUND: Diffusion-weighted imaging (DWI) has shown promise to screen for breast cancer without a contrast injection, but image distortion and low spatial resolution limit standard single-shot DWI. Multishot DWI methods address these limitations but introduce shot-to-shot phase variations requiring correction during reconstruction. PURPOSE: To investigate the performance of two multishot DWI reconstruction methods, multiplexed sensitivity encoding (MUSE) and shot locally low-rank (shot-LLR), compared to single-shot DWI in the breast. STUDY TYPE: Prospective. POPULATION: A total of 45 women who consented to have multishot DWI added to a clinically indicated breast MRI. FIELD STRENGTH/SEQUENCES: Single-shot DWI reconstructed by parallel imaging, multishot DWI with four or eight shots reconstructed by MUSE and shot-LLR, 3D T2 -weighted imaging, and contrast-enhanced MRI at 3T. ASSESSMENT: Three blinded observers scored images for 1) general image quality (perceived signal-to-noise ratio [SNR], ghosting, distortion), 2) lesion features (discernment and morphology), and 3) perceived resolution. Apparent diffusion coefficient (ADC) of the lesion was also measured and compared between methods. STATISTICAL TESTS: Image quality features and perceived resolution were assessed with a mixed-effects logistic regression. Agreement among observers was estimated with a Krippendorf's alpha using linear weighting. Lesion feature ratings were visualized using histograms, and correlation coefficients of lesion ADC between different methods were calculated. RESULTS: MUSE and shot-LLR images were rated to have significantly better perceived resolution (P < 0.001), higher SNR (P < 0.005), and a lower level of distortion (P < 0.05) with respect to single-shot DWI. Shot-LLR showed reduced ghosting artifacts with respect to both MUSE (P < 0.001) and single-shot DWI (P < 0.001). Eight-shot DWI had improved perceived SNR and perceived resolution with respect to four-shot DWI (P < 0.005). DATA CONCLUSION: Multishot DWI enables increased resolution and improved image quality with respect to single-shot DWI in the breast. Shot-LLR reconstructs multishot DWI with minimal ghosting artifacts. The improvement of multishot DWI in image quality increases with an increased number of shots. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Artefactos , Femenino , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos , Reproducibilidad de los Resultados
6.
Magn Reson Med ; 84(1): 170-181, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31782557

RESUMEN

PURPOSE: To develop a near-silent and distortionless DWI (sd-DWI) sequence using magnetization-prepared rotating ultrafast imaging sequence. METHODS: A rotating ultrafast imaging sequence was modified with driven-equilibrium diffusion preparation, including eddy-current compensation methods. To compensate for the T1 recovery during readout, a phase-cycling method was used. Both compensation methods were validated in phantoms. The optimized sequence was compared with an EPI diffusion sequence for image distortion, contrast, ADC, and acoustic noise level in phantoms. The sequence was evaluated in 1 brain volunteer, 5 prostate volunteers, and 10 pediatric patients with joint diseases. RESULTS: Combination of several eddy-current compensation methods reduced the artifact to an acceptable level. Phase cycling reduced T1 recovery contamination during readout. In phantom scans, the optimized sequence generated similar image contrast to the EPI diffusion sequence, and ADC maps between the sequences were comparable; sd-DWI had significantly lower acoustic noise (P < .05). In vivo brain scan showed reduced image distortion in sd-DWI compared with the EPI diffusion, although residual motion artifact remains due to brain pulsation. The prostate scans showed that sd-DWI can provide similar ADC compared with EPI diffusion, with no image distortion. Patient scans showed that the sequence can clearly depict joint lesions. CONCLUSION: An sd-DWI sequence was developed and optimized. Compared with conventional EPI diffusion, sd-DWI provided similar diffusion contrast, accurate ADC measurement, improved image quality, and minimal ambient scanning noise. The sequence showed the ability to obtain in vivo diffusion contrast in relatively motion-free body regions, such as prostate and joint.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Artefactos , Encéfalo/diagnóstico por imagen , Niño , Humanos , Masculino , Fantasmas de Imagen , Reproducibilidad de los Resultados
7.
Magn Reson Med ; 81(2): 1181-1190, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30346058

RESUMEN

PURPOSE: The goal of this work is to propose a motion robust reconstruction method for diffusion-weighted MRI that resolves shot-to-shot phase mismatches without using phase estimation. METHODS: Assuming that shot-to-shot phase variations are slowly varying, spatial-shot matrices can be formed using a local group of pixels to form columns, in which each column is from a different shot (excitation). A convex model with a locally low-rank constraint on the spatial-shot matrices is proposed. In vivo brain and breast experiments were performed to evaluate the performance of the proposed method. RESULTS: The proposed method shows significant benefits when the motion is severe, such as for breast imaging. Furthermore, the resulting images can be used for reliable phase estimation in the context of phase-estimation-based methods to achieve even higher image quality. CONCLUSION: We introduced the shot-locally low-rank method, a reconstruction technique for multishot diffusion-weighted MRI without explicit phase estimation. In addition, its motion robustness can be beneficial to neuroimaging and body imaging.


Asunto(s)
Encéfalo/diagnóstico por imagen , Mama/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Artefactos , Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora , Análisis de Fourier , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Movimiento (Física) , Reproducibilidad de los Resultados
10.
Magn Reson Med ; 78(6): 2136-2148, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28074498

RESUMEN

PURPOSE: To develop a radial, double-echo steady-state (DESS) sequence with ultra-short echo-time (UTE) capabilities for T2 measurement of short-T2 tissues along with simultaneous rapid, signal-to-noise ratio (SNR)-efficient, and high-isotropic-resolution morphological knee imaging. METHODS: THe 3D radial UTE readouts were incorporated into DESS, termed UTEDESS. Multiple-echo-time UTEDESS was used for performing T2 relaxometry for short-T2 tendons, ligaments, and menisci; and for Dixon water-fat imaging. In vivo T2 estimate repeatability and SNR efficiency for UTEDESS and Cartesian DESS were compared. The impact of coil combination methods on short-T2 measurements was evaluated by means of simulations. UTEDESS T2 measurements were compared with T2 measurements from Cartesian DESS, multi-echo spin-echo (MESE), and fast spin-echo (FSE). RESULTS: UTEDESS produced isotropic resolution images with high SNR efficiency in all short-T2 tissues. Simulations and experiments demonstrated that sum-of-squares coil combinations overestimated short-T2 measurements. UTEDESS measurements of meniscal T2 were comparable to DESS, MESE, and FSE measurements while the tendon and ligament measurements were less biased than those from Cartesian DESS. Average UTEDESS T2 repeatability variation was under 10% in all tissues. CONCLUSION: The T2 measurements of short-T2 tissues and high-resolution morphological imaging provided by UTEDESS makes it promising for studying the whole knee, both in routine clinical examinations and longitudinal studies. Magn Reson Med 78:2136-2148, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética , Tejido Adiposo/diagnóstico por imagen , Adulto , Algoritmos , Femenino , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Articulación de la Rodilla/diagnóstico por imagen , Ligamentos/diagnóstico por imagen , Masculino , Meniscos Tibiales/diagnóstico por imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido , Tendones/diagnóstico por imagen
13.
J Magn Reson Imaging ; 41(3): 616-23, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24585455

RESUMEN

PURPOSE: To investigate the diagnostic accuracy and clinical usefulness of the rim sign in breast lesions observed in diffusion-weighted magnetic resonance imaging (DWI). MATERIALS AND METHODS: The magnetic resonance imaging (MRI) findings of 98 pathologically confirmed lesions (62 malignant and 36 benign) in 84 patients were included. Five breast radiologists were asked to independently review the breast MRI results, to grade the degree of high peripheral signal, the "rim sign," in the DWI, and to confirm the mean apparent diffusion coefficient (ADCmean ) values. We analyzed the diagnostic accuracy and compared the consensus (when ≥ 4 of 5 independent reviewers agreed) results of the rim sign with the ADCmean values. Additionally, we evaluated the correlation between the dynamic contrast-enhanced (DCE)-MRI morphologic appearance and DWI rim sign. RESULTS: According to the consensus results, the rim sign in DWI was observed on 59.7% of malignant lesions and 19.4% of benign lesions. The sensitivity, specificity, and area under the curve (AUC) value for the rim sign in DWI were 59.7%, 80.6%, and 0.701, respectively. The sensitivity, specificity, and AUC value for the ADCmean value (criteria ≤ 1.46 × 10(-3) mm(2) /sec) were 82.3%, 63.9%, and 0.731, respectively. Based on consensus, no correlation was observed between the DCE-MRI and DWI rim signs. CONCLUSION: In DWI, a high-signal rim is a valuable morphological feature for improving specificity in DWI.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen de Difusión por Resonancia Magnética , Interpretación de Imagen Asistida por Computador/métodos , Adulto , Anciano , Mama/patología , Medios de Contraste , Femenino , Gadolinio , Humanos , Aumento de la Imagen , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
14.
Magn Reson Med ; 71(1): 95-104, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23504943

RESUMEN

Radial trajectories facilitate high-resolution balanced steady state free precession (bSSFP) because the efficient gradients provide more time to extend the trajectory in k-space. A number of radial bSSFP methods that support fat-water separation have been developed; however, most of these methods require an environment with limited B0 inhomogeneity. In this work, high-resolution bSSFP with fat-water separation is achieved in more challenging B0 environments by combining a 3D radial trajectory with the IDEAL chemical species separation method. A method to maintain very high resolution within the timing constraints of bSSFP and IDEAL is described using a dual-pass pulse sequence. The sampling of a unique set of radial lines at each echo time is investigated as a means to circumvent the longer scan time that IDEAL incurs as a multiecho acquisition. The manifestation of undersampling artifacts in this trajectory and their effect on chemical species separation are investigated in comparison to the case in which each echo samples the same set of radial lines. This new bSSFP method achieves 0.63 mm isotropic resolution in a 5-min scan and is demonstrated in difficult in vivo imaging environments, including the breast and a knee with ACL reconstruction hardware at 1.5 T.


Asunto(s)
Algoritmos , Lesiones del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/patología , Mama/anatomía & histología , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Ligamento Cruzado Anterior/cirugía , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
J Magn Reson Imaging ; 39(2): 332-8, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23596017

RESUMEN

PURPOSE: To evaluate the performance of 2D versus 3D T2-weighted spin echo imaging in the breast. MATERIALS AND METHODS: 2D and 3D T2-weighted images were acquired in 25 patients as part of a clinically indicated breast magnetic resonance imaging (MRI) exam. Lesion-to-fibroglandular tissue signal ratio was measured in 16 identified lesions. Clarity of lesion morphology was assessed through a blinded review by three radiologists. Instances demonstrating the potential diagnostic contribution of 3D versus 2D T2-weighted imaging in the breast were noted through unblinded review by a fourth radiologist. RESULTS: The lesion-to-fibroglandular tissue signal ratio was well correlated between 2D and 3D T2-weighted images (R(2) = 0.93). Clarity of lesion morphology was significantly better with 3D T2-weighted imaging for all observers based on a McNemar test (P ≤ 0.02, P ≤ 0.01, P ≤ 0.03). Instances indicating the potential diagnostic contribution of 3D T2-weighted imaging included improved depiction of signal intensity and improved alignment between DCE and T2-weighted findings. CONCLUSION: In this pilot study, 3D T2-weighted imaging provided comparable contrast and improved depiction of lesion morphology in the breast in comparison to 2D T2-weighted imaging. Based on these results further investigation to determine the diagnostic impact of 3D T2-weighted imaging in breast MRI is warranted.


Asunto(s)
Algoritmos , Neoplasias de la Mama/patología , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Femenino , Humanos , Aumento de la Imagen/métodos , Variaciones Dependientes del Observador , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Marcadores de Spin
16.
Magn Reson Imaging ; 31(9): 1472-8, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23895871

RESUMEN

PURPOSE: To compare the image quality of three techniques and diagnostic performance in detecting implant rupture. MATERIALS AND METHODS: The study included 161 implants for the evaluation of image quality, composed of water-saturated short TI inversion recovery (herein called "water-sat STIR"), three-point Dixon techniques (herein called "Dixon"), and short TI inversion recovery fast spin-echo with iterative decomposition of silicone and water using least-squares approximation (herein called "STIR IDEAL") and included 41 implants for the evaluation of diagnostic performance in detecting rupture, composed of water-sat STIR and STIR IDEAL. Six image quality categories were evaluated and three classifications were used: normal implant, possible rupture, and definite rupture. RESULTS: Statistically significant differences were noted for the image quality categories (p<0.001). STIR IDEAL was superior or equal to water-sat STIR in all image quality categories except artifact effects and superior to Dixon in all categories. Water-sat STIR performed the poorest for water suppression uniformity. The sensitivity and specificity in detecting implant rupture of STIR-IDEAL were 81.8 % and 77.8 % and the difference between two techniques was not statistically significant. CONCLUSION: STIR-IDEAL is a useful silicone-specific imaging technique demonstrating more robust water suppression and equivalent diagnostic accuracy for detecting implant rupture, than water-sat STIR, at the cost of longer scan time and an increase in minor motion artifacts.


Asunto(s)
Implantes de Mama , Mama/patología , Imagen por Resonancia Magnética , Falla de Prótesis , Siliconas/química , Tejido Adiposo/patología , Adulto , Algoritmos , Artefactos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Análisis de los Mínimos Cuadrados , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
17.
J Magn Reson Imaging ; 30(1): 135-44, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19557728

RESUMEN

PURPOSE: To assess a 3D radial balanced steady-state free precession (SSFP) technique that provides submillimeter isotropic resolution and inherently registered fat and water image volumes in comparison to conventional T2-weighted RARE imaging for lesion characterization in breast magnetic resonance imaging (MRI). MATERIALS AND METHODS: 3D projection SSFP (3DPR-SSFP) combines a dual half-echo radial k-space trajectory with a linear combination fat/water separation technique (linear combination SSFP). A pilot study was performed in 20 patients to assess fat suppression and depiction of lesion morphology using 3DPR-SSFP. For all patients fat suppression was measured for the 3DPR-SSFP image volumes and depiction of lesion morphology was compared against corresponding T2-weighted fast spin echo (FSE) datasets for 15 lesions in 11 patients. RESULTS: The isotropic 0.63 mm resolution of the 3DPR-SSFP sequence demonstrated improved depiction of lesion morphology in comparison to FSE. The 3DPR-SSFP fat and water datasets were available in a 5-minute scan time while average fat suppression with 3DPR-SSFP was 71% across all 20 patients. CONCLUSION: 3DPR-SSFP has the potential to improve the lesion characterization information available in breast MRI, particularly in comparison to conventional FSE. A larger study is warranted to quantify the effect of 3DPR-SSFP on specificity.


Asunto(s)
Adenocarcinoma/patología , Neoplasias de la Mama/patología , Fibroadenoma/patología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Tejido Adiposo , Agua Corporal , Mama/patología , Quiste Mamario/patología , Femenino , Humanos , Proyectos Piloto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA