Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Pediatr Cardiol ; 45(2): 323-330, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37707592

RESUMEN

Therapies to support small infants in decompensated heart failure that are failing medical management are limited. We have used the hybrid approach, classically reserved for high-risk infants with single ventricle physiology, in patients with biventricular physiology with left ventricular failure. This approach secures systemic circulation, relieves left atrial hypertension, protects the pulmonary vasculature, and allows the right ventricle to support cardiac output. This approach can be used as a bridge to transplantation in select individuals. Infants without single ventricle congenital heart disease who were treated with the hybrid approach between 2008 and 2021 were included in analysis. Eight patients were identified. At the time of hybrid procedure, the median weight was 3.2 kg (range 2.4-3.6 kg) and the median age was 18 days (range 1-153 days). Seventy five percent were mechanically ventilated and 88% were on inotropic support. The median duration from hybrid procedure to transplant was 63 days (range 4-116 days). All patients experienced a good outcome (delisted for improvement or transplanted). The hybrid procedure is an appropriate therapeutic bridge to transplantation in a carefully selected subset of critically ill infants without single ventricle congenital heart disease in whom alternate therapies may confer increased risk for morbidity and mortality.


Asunto(s)
Cardiopatías Congénitas , Trasplante de Corazón , Síndrome del Corazón Izquierdo Hipoplásico , Lactante , Humanos , Resultado del Tratamiento , Ventrículos Cardíacos , Estudios Retrospectivos
2.
Catheter Cardiovasc Interv ; 102(6): 1078-1087, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37925624

RESUMEN

BACKGROUND: The Harmony TPV25 transcatheter pulmonary valve (Medtronic Inc.) is constructed with a self-expanding stent frame comprising six zigged nitinol wires sewn together and covered with knitted polyester fabric, with flared inflow and outflow ends and a porcine pericardial valve sutured to the central portion of the device. It was approved for treatment of pulmonary regurgitation after prior right ventricular outflow tract repair in 2021. Early outcomes of this procedure have been excellent, but little is known about valve durability or ultimate mechanisms of dysfunction. METHODS: We collected data on patients who underwent reintervention for TPV25 dysfunction and described findings related to distortion of the stent frame and tissue accumulation. RESULTS: We describe six patients who underwent valve-in-valve implant for TPV25 obstruction (peak catheterization gradient peak 28-73 mmHg) 10-28 months after implant. In all cases, there was tissue accumulation within the inflow and valve-housing segments of the device and deformation of the self-expanding valve frame characterized by variable circumferential narrowing at the junction between the valve housing and the inflow and outflow portions of the device, with additional geometric changes in all segments. All six patients underwent valve-in-valve implant that results in a final peak gradient ≤10 mmHg and no regurgitation. DISCUSSION: The occurrence of short-term Harmony TPV25 dysfunction in multiple patients with a similar appearance of frame distortion and tissue accumulation within the inflow and valve housing portions of the device suggests that this may be an important failure mechanism for this valve. Potential causes of the observed findings are discussed. It is possible to treat this mechanism of TPV25 dysfunction with valve-in-valve implant using balloon expandable transcatheter valves.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Obstrucción del Flujo de Salida Ventricular Derecho , Obstrucción del Flujo Ventricular Externo , Humanos , Porcinos , Animales , Prótesis Valvulares Cardíacas/efectos adversos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Stents/efectos adversos , Diseño de Prótesis
3.
Pediatr Transplant ; 28(2): e14636, 2023 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-37927113

RESUMEN

BACKGROUND: Pulmonary vein stenosis (PVS) is a rare pediatric condition associated with significant mortality and morbidity. PVS in patients following heart transplant (HT) has not yet been described. METHODS: Patients who had clinically significant PVS following a heart transplant during the time period of April 1, 2013 to April 30, 2023, at Seattle Children's Hospital were identified. Clinically significant PVS was defined as an atretic vein or a vein with a gradient of ≥4 mmHg across at least one vein by echocardiogram or during cardiac catheterization. Patients who had a diagnosis of PVS prior to their transplant were excluded. A total of six patients were identified. We collected clinical data on these patients from their pre-transplant course to their most recent status. RESULTS: The median age at HT was 7.5 months (range 2-13 months). The median time from HT to diagnosis of PVS was 3.5 months (range 0.3-13 months). At the last follow-up, the patients had had two to five pulmonary vein interventions, and there were no mortalities. The donor-to-recipient weight and total cardiac volume (TCV) ratios were less than 2.0 in five of six of the patients. CONCLUSIONS: PVS is a rare complication that is associated with patients who undergo HT during infancy. PVS develops soon after HT and screening should occur accordingly. Interestingly, high donor-to-recipient weight and TCV ratios are not necessarily associated with the development of PVS. Further work will need to be performed in order to determine the significance of PVS in post-HT patients.

4.
Pediatr Cardiol ; 43(7): 1438-1443, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35274168

RESUMEN

Determine outcomes of catheter intervention for aortic coarctation in infants. Aortic coarctation in infants following surgical repair and in high surgical risk native cases remains a challenging problem. Catheter intervention is an alternative to surgical intervention. Single-center, chart review of infants with biventricular anatomy who underwent coarctation stent placement or balloon angioplasty between 04/2004 and 04/2020. Outcomes of interest included change in aortic lumen diameter, peak gradient, number of re-interventions, time to re-intervention, and adverse events. Thirty-four patients were included in analysis, of those 16 underwent stent placement. Patients' mean age was 4.0 ± 3.0 months and weight of 5.3 ± 1.9 kg. Follow-up interval was 5.4 ± 5.1 years (0.2-16.1 years). Twelve (35%) patients underwent procedure due to ventricular dysfunction; the rest were for high resting gradient. Coarctation diameter increased from 2.4 ± 1.0 to 4.5 ± 1.3 (p < 0.01) and gradient decreased from 32.0 ± 18.4 mmHg to 9.2 ± 8.8 mmHg (p < 0.01). Thirteen (81%) of the stented patients required at least one re-intervention, at an average of 1.7 ± 3.2 years from the index procedure. Five (28%) of those undergoing balloon angioplasty required repeat intervention. There was no mortality due to the procedure and one late mortality. One patient had a serious procedural adverse event. On follow-up, 12 (35%) were on anti-hypertensive medications. Catheter intervention, including stent placement, for aortic coarctation in infants is feasible with an acceptable adverse event profile. Repeat interventions are common.


Asunto(s)
Angioplastia de Balón , Coartación Aórtica , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/métodos , Antihipertensivos , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/cirugía , Estudios de Seguimiento , Humanos , Lactante , Recurrencia , Estudios Retrospectivos , Stents , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 98(5): 904-913, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34398509

RESUMEN

The Society for Cardiovascular Angiography and Interventions (SCAI) Think Tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community annually for high-level field-wide discussions. The 2021 Think Tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease. Each session was moderated by a senior content expert and co-moderated by a member of SCAI's Emerging Leader Mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialog from a broader base, and thereby aid SCAI, the industry community and external stakeholders in developing specific action items to move these areas forward.


Asunto(s)
Cardiólogos , Cardiología , Cardiopatías Congénitas , Angiografía , Humanos , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 96(6): 1266-1276, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32433821

RESUMEN

OBJECTIVES: Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure. BACKGROUND: The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature. METHODS: This was a single arm, prospective, multicenter, non-randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g. From June 2017 to February 2019, 200 patients were enrolled at nine centers, with 100 patients weighing ≤2 kg. Primary effectiveness endpoint was the rate of PDA closure at 6-month follow-up. Primary safety endpoint was the rate of major complications through 6 months. Secondary endpoint was rate of significant pulmonary or aortic obstruction through 6 months' follow-up. RESULTS: The implant success rate was 95.5% (191/200) overall and 99% in patients ≤2 kg (99/100). The primary effectiveness endpoint was achieved in 99.4% of implanted patients. Four patients experienced a primary safety endpoint event (2 transfusions, 1 hemolysis, and 1 aortic obstruction). There were no branch pulmonary artery obstructions. Five patients, all ≤2 kg, were noted to have worsening of tricuspid regurgitation (TR) after the procedure. None of the TR incidences manifested clinically. The Amplatzer Piccolo Occluder received FDA approval in January 2019 and became the first device approved for PDA closure in patients ≥700 g. CONCLUSIONS: This study supports the safety and effectiveness of the Amplatzer Piccolo Occluder, particularly in patients between 700 g and 2 kg where there is currently a significant unmet need in the United States. ClinicalTrials.gov identifier: NCT03055858.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Conducto Arterioso Permeable/terapia , Recien Nacido Extremadamente Prematuro , Recién Nacido de muy Bajo Peso , Dispositivo Oclusor Septal , Peso al Nacer , Cateterismo Cardíaco/efectos adversos , Circulación Coronaria , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/fisiopatología , Femenino , Edad Gestacional , Hemodinámica , Humanos , Recién Nacido , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
7.
Catheter Cardiovasc Interv ; 96(6): 1258-1265, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32840956

RESUMEN

The society for cardiovascular angiography and interventions (SCAI) think tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community for high-level field-wide discussions. The 2020 think tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease (CHD). Each session was moderated by a senior content expert and co-moderated by a member of SCAI's emerging leader mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialogue from a broader base, and thereby aid SCAI and the industry community in developing specific action items to move these areas forward.


Asunto(s)
Cateterismo Cardíaco/tendencias , Cardiología/tendencias , Angiografía Coronaria/tendencias , Cardiopatías/diagnóstico por imagen , Cardiopatías/terapia , Intervención Coronaria Percutánea/tendencias , Difusión de Innovaciones , Cardiopatías/fisiopatología , Humanos
8.
Catheter Cardiovasc Interv ; 94(4): 618-624, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31424167

RESUMEN

OBJECTIVES: To define patient and ventricular size parameters to guide Impella device (Abiomed, Inc., Danvers, MA) placement for mechanical circulatory support (MCS) in small pediatric patients (10-30 kg). BACKGROUND: There are few options for MCS in children, and there are no data on minimum patient size requirements for placement of the Impella 2.5 device. METHODS: This was a multicenter study of echocardiographic and magnetic resonance imaging (MRI) derived dimensions of the left ventricle (LV) length and ascending aorta used to define minimum size parameters that are necessary for the placement of the Impella catheter. RESULTS: Data were collected from 44 cardiac MRIs conducted in healthy pediatric patients and 39 echocardiograms performed in pediatric patients with cardiomyopathy prior to surgical ventricular assist device (VAD) placement. The Impella 2.5 catheter is 7.5 cm from the pigtail to the aortic annulus marker, thus requiring an LV apical length of 7.5 cm to allow the device to function in an unconstrained fashion. In the cohort of patients undergoing consideration for VAD placement, a minimum LV length of 7.5 cm corresponded to a height of 122 cm, weight of 23 kg, and body surface area (BSA) of 0.89 m2 . In the MRI cohort, this corresponded to a height of 121 cm, weight of 23.9 kg, and BSA of 0.89 m2 . CONCLUSION: MCS with Impella devices is feasible in pediatric patients. This study defines anthropomorphic and anatomic measurements to guide providers in patient selection for MCS using the Impella devices.


Asunto(s)
Estatura , Peso Corporal , Toma de Decisiones Clínicas , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Implantación de Prótesis/instrumentación , Función Ventricular Izquierda , Superficie Corporal , Niño , Preescolar , Ecocardiografía , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Humanos , Lactante , Imagen por Resonancia Magnética , Masculino , Selección de Paciente , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Recuperación de la Función , Estudios Retrospectivos , Resultado del Tratamiento , Estados Unidos
9.
Catheter Cardiovasc Interv ; 93(3): 474-480, 2019 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-30419603

RESUMEN

OBJECTIVES: This study describes procedural and 1-year outcomes of the 16 mm Melody PB1016 valve in patients with dysfunctional RVOT conduits. BACKGROUND: The Melody PB1016 is a standard Melody valve produced from a 16 mm bovine jugular vein and is intended for deployment up to 20 mm. METHODS: This is a prospective, non-randomized, multicenter study of the procedural and short-term outcomes of Melody PB1016 TPV replacement within dysfunctional RVOT conduits. Data from eight centers were included in the analysis. RESULTS: During the study period, 39 patients underwent attempted Melody TPVR. Of the 39 patients, 30 underwent successful Melody TPVR. The majority of patients underwent placement of one or more stents prior to TPVR. There was a significant reduction in peak conduit pressure gradient following TPVR (38 mmHg vs. 11 mmHg, P < 0.001). There were three cases of confined conduit tears successfully treated with covered stents or the valve itself. Repeat catheterization was performed in one patient for early re-obstruction that was successfully treated with balloon valvuloplasty. At recent follow-up, there were no cases of more than mild valve regurgitation and the mean pulmonary valve gradient by echocardiogram remained reduced relative to pre-TPVR implant measurements (33.5 mmHg vs. 15.2 mmHg). There were no cases of valve stent fracture or endocarditis reported at the 1-year follow-up. CONCLUSIONS: Our analysis of TPVR with the PB1016 valve in RVOT conduits showed it to be safe and effective and can be performed in a wide range of conduit sizes with preserved valve function. ClinicalTrials.gov Identifier: NCT02347189.


Asunto(s)
Bioprótesis , Cateterismo Cardíaco/instrumentación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Cardiopatías Congénitas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Venas Yugulares/trasplante , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Stents , Adolescente , Adulto , Animales , Canadá , Cateterismo Cardíaco/efectos adversos , Bovinos , Niño , Europa (Continente) , Femenino , Cardiopatías Congénitas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Xenoinjertos , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Recuperación de la Función , Resultado del Tratamiento , Estados Unidos , Adulto Joven
10.
J Interv Cardiol ; 2019: 7639754, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32089654

RESUMEN

OBJECTIVES: To quantify radiation exposure during pediatric cardiac catheterizations performed by multiple operators on a new imaging platform, the Artis Q.zen (Siemens Healthcare, Forchheim, Germany), and to compare these data to contemporary benchmark values. BACKGROUND: The Artis Q.zen has been shown to achieve significant radiation reduction during select types of pediatric cardiac catheterizations in small single-center studies. No large multicenter study exists quantifying patient dose exposure for a broad spectrum of procedures. METHODS: Retrospective collection of Air Kerma (AK) and dose area product (DAP) for all pediatric cardiac catheterizations performed on this new imaging platform at four institutions over a two-year time period. RESULTS: A total of 1,127 pediatric cardiac catheterizations were analyzed. Compared to dose data from earlier generation Artis Zee imaging systems, this study demonstrates 70-80% dose reduction (AK and DAP) for similar patient and procedure types. Compared to contemporary benchmark data for common interventional procedures, this study demonstrates an average percent reduction in AK and DAP from the lowest dose saving per intervention of 39% for AK and 27% for DAP for transcatheter pulmonary valve implantation up to 77% reduction in AK and 70% reduction in DAP for atrial septal defect closure. CONCLUSION: Use of next-generation imaging platforms for pediatric cardiac catheterizations can substantially decrease patient radiation exposure. This multicenter study defines new low-dose radiation measures achievable on a novel imaging system.


Asunto(s)
Cateterismo Cardíaco , Cardiopatías/diagnóstico por imagen , Cardiopatías/cirugía , Exposición a la Radiación , Radiografía Intervencional , Adolescente , Niño , Preescolar , Femenino , Fluoroscopía , Humanos , Lactante , Recién Nacido , Masculino , Dosis de Radiación , Estudios Retrospectivos , Medición de Riesgo , Factores de Tiempo
11.
Catheter Cardiovasc Interv ; 91(1): 86-89, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-29068129

RESUMEN

We present a case of successful bicaval Melody valve implantation to treat severe mitral regurgitation in a 44-year-old man with d-transposition of the great arteries, repaired via a Mustard operation. The patient sustained injury to the anterior mitral valve leaflet during laser extraction of a ventricular pacing lead resulting in acute, severe, symptomatic mitral regurgitation. The presence of systemic venous baffles of similar caliber to right ventricular outflow tract conduits allowed for implantation of Melody valves within each baffle. The patient remains asymptomatic with excellent Melody valve function 14 months post procedure.


Asunto(s)
Operación de Switch Arterial , Remoción de Dispositivos/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Transposición de los Grandes Vasos/cirugía , Adulto , Operación de Switch Arterial/efectos adversos , Valvuloplastia con Balón , Ecocardiografía Doppler en Color , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/fisiopatología , Marcapaso Artificial/efectos adversos , Flebografía , Diseño de Prótesis , Radiografía Intervencional , Recuperación de la Función , Índice de Severidad de la Enfermedad , Transposición de los Grandes Vasos/fisiopatología , Resultado del Tratamiento
12.
Pediatr Transplant ; 22(8): e13307, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30338630

RESUMEN

BACKGROUND: The hybrid stage 1 palliation for hypoplastic left heart syndrome (HLHS) was first described in 1993 as a bridge to heart transplant for HLHS. There are limited data on this strategy as primary heart transplantation for HLHS has become less common. METHODS: This is an observational, single-center study comparing pre- and post-transplant outcomes of patients listed for transplant following hybrid palliation with those following surgical stage 1 palliation. RESULTS: From 2004 to 2017, 21 patients underwent hybrid palliation as a bridge to heart transplant and 28 patients were listed for transplant following surgical stage 1 palliation or aortic arch repair and pulmonary artery band placement. Premature birth and the presence of genetic or anatomic abnormalities were more common in the hybrid group. Need for extracorporeal membrane oxygenation (ECMO) support and ventricular dysfunction was more common in the surgical group. There was a trend toward shorter waitlist times in the surgical cohort (36 days vs 70 days, P = 0.06). There was no difference in waitlist mortality (19% vs 21%, P = 0.61). Survival at 1 and 5 years post-transplant was similar for the hybrid and surgical cohorts (5-year survival, 80% vs 85%, P = 0.94, respectively). There was no difference in the number of post-transplant interventions. CONCLUSIONS: Although the hybrid patients represented a higher risk cohort and demonstrated longer wait times, the waitlist and post-transplant mortality was equivalent between the two groups. For high-risk patients, the hybrid palliation as a bridge to transplant appears to be a reasonable strategy.


Asunto(s)
Trasplante de Corazón/métodos , Ventrículos Cardíacos/fisiopatología , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Cuidados Paliativos/métodos , Aorta Torácica/cirugía , Cardiología/métodos , Femenino , Puente Cardíaco Derecho , Humanos , Lactante , Recién Nacido , Masculino , Arteria Pulmonar/cirugía , Estudios Retrospectivos , Riesgo , Resultado del Tratamiento , Listas de Espera
13.
Catheter Cardiovasc Interv ; 90(1): 124-129, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28295963

RESUMEN

OBJECTIVES: The objective was to review the use of Impella devices (Abiomed Inc, Danvers, MA) for temporary circulatory support in pediatric and adolescent patients (age ≤ 21 yrs). BACKGROUND: Options for minimally invasive circulatory support in children are limited, and published data are confined to case reports and small case series. METHODS: This was a retrospective, multicenter review of Impella implants in pediatric and adolescent patients from 2009-15, using standardized data collection and INTERMACS definitions. RESULTS: A total of 39 implants were performed in 38 patients from 16 centers. Median age and weight were 16 yrs (4-21 yrs) and 62 kg (15-134 kg). The primary indication for implant was cardiogenic shock in 28 patients (72%). Cardiac allograft rejection, myocarditis, or cardiomyopathy were the underlying diagnosis in 23 patients (59%); 11 patients had congenital heart disease. The median duration of support was 45 hr (1-1224 hr). Indications for explant included ventricular recovery in 16 patients, transition to another device in 12, death in 5, and transplant in 1. Survival was 85% at 7 days and 68% at 30 days. Major adverse events occurred in 8 patients: hemolysis in 3, bleeding in 2, stroke in 1 (unclear if related to Impella), sepsis in 1, and critical leg ischemia in 1. An increase in aortic regurgitation was noted in three patients, with no evidence of valve injury. CONCLUSION: Temporary circulatory support with Impella devices is feasible in pediatric and adolescent patients, with acceptable risk profiles. More experience and follow up is needed to improve technical performance and patient selection. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Procedimiento de Fontan/efectos adversos , Cardiopatías Congénitas/cirugía , Corazón Auxiliar , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Adolescente , Niño , Preescolar , Estudios de Factibilidad , Femenino , Cardiopatías Congénitas/fisiopatología , Humanos , Masculino , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología , Adulto Joven
14.
Catheter Cardiovasc Interv ; 90(1): 118-123, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28112463

RESUMEN

BACKGROUND: There are limited mechanical circulatory support options for patients with single ventricle (SV) anatomy. This is a multicenter, retrospective study of the Impella pump to support the systemic ventricle in a cohort of SV patients with Fontan circulation. METHODS: Patients with SV anatomy supported with an Impella device from 2012 to 2015 were included. Demographic information, indication for support, adverse events and short-term outcome data were collected. RESULTS: Ten patients were included. The median age and weight at implant was 26 years (4-38 years) and 64 kg (15-102 kg). Indications for support were systemic ventricular failure with cardiogenic shock (n = 8) or high-risk electrophysiology (EP) procedures (n = 2). The median duration of support was 49 hr (2.7-264 hr). Support was discontinued for ventricular recovery in five patients, transition to another device in two patients, completion of EP procedure in two patients and death in one patient. Survival to hospital discharge was 80%. Adverse events occurred in 4 patients. There were two cases of hemolysis, one case of increasing aortic valve insufficiency with implant and one asymptomatic access site thrombus. There were no bleeding or thromboembolic events. CONCLUSIONS: Impella devices can provide temporary support for the systemic ventricle in SV patients as a bridge to recovery or additional device. Procedural survival and adverse event profiles are favorable. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Procedimiento de Fontan/efectos adversos , Cardiopatías Congénitas/cirugía , Corazón Auxiliar , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Adolescente , Adulto , Preescolar , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Europa (Continente) , Femenino , Procedimiento de Fontan/mortalidad , Cardiopatías Congénitas/mortalidad , Cardiopatías Congénitas/fisiopatología , Mortalidad Hospitalaria , Humanos , Masculino , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología , Adulto Joven
15.
ASAIO J ; 70(7): 602-608, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38949774

RESUMEN

We report the largest pediatric multicenter experience with Impella pump use and peripheral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support. Utilizing the Advanced Cardiac Therapies Improving Outcomes Network (ACTION) collaborative database, we conducted a retrospective, multicenter study of all patients with cardiogenic shock requiring VA-ECMO support with subsequent Impella implant between October 2014 and December 2021. The primary outcome was defined as death while on Impella support. Secondary outcomes were recovery, transplantation, and transition to durable ventricular assist device (VAD) at the time of Impella explantation. Adverse events were defined according to the ACTION registry criteria. Twenty subjects were supported with Impella; Impella 2.5 (n = 3), CP (n = 12), 5.0/5.5 (n = 5). The median Interquartile range (IQR) age, weight, and body surface area at implantation were 15.6 years (IQR = 13.9-17.2), 65.7 kg (IQR = 53.1-80.7), and 1.74 m2 (IQR = 1.58-1.98). Primary cardiac diagnoses were dilated cardiomyopathy/myocarditis in nine (45%), congenital heart disease in four (20%), graft failure/rejection in four (20%), and three (15%) others. Most common adverse events included hemolysis (50%) and bleeding (20%). There were two deaths (10%) in the cohort. Nine patients (45%) were explanted for recovery, eight (40%) were transitioned to a durable VAD, and one (5%) underwent heart transplantation. Impella percutaneous pump support should be considered in the older pediatric population supported with peripheral VA-ECMO, as a means of left heart decompression, and a strategy to come off ECMO to achieve endpoints of myocardial recovery, transition to a durable VAD, or transplantation.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Choque Cardiogénico , Humanos , Oxigenación por Membrana Extracorpórea/métodos , Oxigenación por Membrana Extracorpórea/efectos adversos , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Masculino , Femenino , Adolescente , Choque Cardiogénico/terapia , Niño , Preescolar , Resultado del Tratamiento
16.
Circ Cardiovasc Interv ; 17(5): e013889, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38606564

RESUMEN

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Válvula Pulmonar , Humanos , Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Masculino , Femenino , Adolescente , Adulto Joven , Niño , Adulto , Estudios Retrospectivos , Valor Predictivo de las Pruebas , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Selección de Paciente , Toma de Decisiones Clínicas , Recuperación de la Función , Hemodinámica
17.
Circ Cardiovasc Interv ; 17(7): e013729, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38666384

RESUMEN

BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight (P=0.018), body surface area (P=0.013), and minimum-to-descending aortic diameter ratio (P<0.001) were associated with higher baseline aortic gradient. The residual gradient was inversely associated with implant and final dilation diameters (P<0.001). The combined incidence of aortic injury and stent-related complications was 14%. There were no reports of abnormal brain scans or stroke. Blood pressure cuff gradient, echocardiographic arch velocity, and hypertension rates improved within 1-year follow-up with increased antihypertensive medication use. Reintervention was reported in 60 (41%) patients at a median of 84 (22-148) months to first reintervention. On multivariable logistic regression, residual aortic gradient >10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells.


Asunto(s)
Angioplastia de Balón , Aorta Torácica , Diseño de Prótesis , Stents , Humanos , Estudios Retrospectivos , Masculino , Femenino , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aorta Torácica/fisiopatología , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Adolescente , Adulto Joven , Angioplastia de Balón/instrumentación , Angioplastia de Balón/efectos adversos , Niño , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/terapia , Enfermedades de la Aorta/fisiopatología , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Arteriopatías Oclusivas/terapia , Constricción Patológica , Estados Unidos , Aortografía
18.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38569760

RESUMEN

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Adulto , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Sistema de Registros , Diseño de Prótesis , Estudios Retrospectivos
19.
Circ Cardiovasc Interv ; 16(7): e012697, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37417230

RESUMEN

BACKGROUND: Covered stent (CS) use for the transcatheter treatment of coarctation of the aorta (COA) was first described over 20 years ago. The covered Cheatham-platinum stent received Food and Drug Administration approval for COA treatment in 2016. Data collected as part of the National Cardiovascular Data Registry IMPACT registry were evaluated for contemporary usage patterns of CS for the treatment of COA from 2016 to 2021. METHODS: Version 2 of the IMPACT registry was queried for all patients who underwent stent placement for treatment of COA from 2016 to 2021. Trends in CS use were evaluated by year and age of patient at the time of implant. Analysis was limited to clinical factors collected as part of the registry and was performed to identify factors associated with CS use. RESULTS: Data were available for 1989 case entries. Most patients (92%) received a single stent. The overall percentage of CS use in the cohort was 23% and remained consistent throughout the study period. The probability of CS use was significantly associated with increasing patient age at implant. Additional factors associated with CS use included smaller initial COA diameter, native COA, and the presence of a pseudoaneurysm. Procedural adverse event rates were low. CONCLUSIONS: CS use to treat COA was more common in adult patients and remained stable over the study period. Factors associated with CS use, including smaller COA diameter and aortic pseudoaneurysm, demonstrate the perceived value of CS as a tool to reduce the risk of aortic wall injury during treatment of COA.


Asunto(s)
Aneurisma Falso , Coartación Aórtica , Enfermedades de la Aorta , Adulto , Humanos , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/terapia , Aortografía , Resultado del Tratamiento , Aneurisma Falso/etiología , Stents/efectos adversos , Enfermedades de la Aorta/complicaciones
20.
J Perinatol ; 43(10): 1238-1244, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37587183

RESUMEN

OBJECTIVE: This study describes 3-year follow-up of 200 infants weighing ≥ 700 grams who underwent transcatheter patent ductus arteriosus (PDA) closure with the Amplatzer Piccolo™ Occluder. STUDY DESIGN: Between June 2017 and February 2019, 200 children were enrolled in this U.S. study (NCT03055858). PDA closure, survival, and device- or procedure-related events were evaluated. A total of 156 of the available 182 patients (86%) completed the study. RESULTS: The implant success rate was 95.5% (191/200). At 3 years, PDA closure was observed in 100% (33/33) of patients. Survival was >95% with 9 reported deaths. No deaths were adjudicated as device- or procedure-related. Notable events included aortic obstruction (2) requiring stent placement and tricuspid regurgitation (5), for which no interventions were required. CONCLUSIONS: This follow-up study demonstrates high rates of PDA closure, low serious complication rates, and survival > 95% at 3 years. The Amplatzer Piccolo™ Occluder is a safe and effective therapy for PDA treatment in premature infants. CLINICALTRIALS: gov identifier: NCT0305585.


Asunto(s)
Conducto Arterioso Permeable , Dispositivo Oclusor Septal , Lactante , Humanos , Niño , Estudios de Seguimiento , Conducto Arterioso Permeable/cirugía , Estudios Prospectivos , Cateterismo Cardíaco/efectos adversos , Dispositivo Oclusor Septal/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA