Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 458
Filtrar
Más filtros

Intervalo de año de publicación
1.
Europace ; 21(2): 339-346, 2019 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-29947754

RESUMEN

AIMS: Prospective data regarding the role of implantable cardioverter-defibrillator (ICD) for the primary prevention of sudden cardiac death in patients with long QT syndrome (LQTS) is scarce. Herein, we explore the prospective Rochester LQTS ICD registry to assess the risk for appropriate shock in primary prevention in a real-world setting. METHODS AND RESULTS: We studied 212 LQTS patients that had ICD implantation for primary prevention. Best-subsets proportional-hazards regression analysis was used to identify clinical variables that were associated with the first appropriate shock. Conditional models of Prentice, Williams, and Peterson were utilized for the analysis of recurrent appropriate shocks. During a median follow-up of 9.2 ± 4.9 years, there were 42 patients who experienced at least one appropriate shock and the cumulative probability of appropriate shock at 8 years was 22%. QTc ≥ 550 ms [hazard ratio (HR) 3.94, confidence interval (CI) 2.08-7.46; P < 0.001) and prior syncope on ß-blockers (HR 1.92, CI 1.01-3.65; P = 0.047) were associated with increased risk of appropriate shock. History of syncope while on ß-blocker treatment (HR 1.87, CI 1.28-2.72; P = 0.001), QTc 500-549 ms (HR 1.68, CI 1.10-2.81; P = 0.048), and QTc ≥ 550 ms (HR 3.66, CI 2.34-5.72; P < 0.001) were associated with increased risk for recurrent appropriate shocks, while ß-blockers were not protective (HR 1.03, CI 0.63-1.68, P = 0.917). LQT2 (HR 2.10, CI 1.22-3.61; P = 0.008) and multiple mutations (HR 2.87, CI 1.49-5.53; P = 0.002) were associated with higher risk for recurrent shocks as compared with LQT1. CONCLUSION: In this prospective ICD registry, we identified clinical and genetic variables that were associated appropriate shock risk. These data can be used for risk stratification in high-risk patients evaluated for primary prevention with ICD.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Síndrome de QT Prolongado/terapia , Prevención Primaria/instrumentación , Adolescente , Antagonistas Adrenérgicos beta/uso terapéutico , Adulto , Antiarrítmicos/uso terapéutico , Niño , Preescolar , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Predisposición Genética a la Enfermedad , Humanos , Lactante , Síndrome de QT Prolongado/genética , Síndrome de QT Prolongado/mortalidad , Síndrome de QT Prolongado/fisiopatología , Masculino , Minnesota , Mutación , Falla de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
2.
J Cardiovasc Electrophysiol ; 29(10): 1418-1424, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29978932

RESUMEN

INTRODUCTION: Data on inappropriate and appropriate ICD therapy, and efficacy of ICD programing strategies by race are limited. METHODS: In MADIT-RIT, we evaluated the risk of ICD therapy by race, and the efficacy of high rate cut-off ventricular tachycardia (VT) zone ≥200 beats per minute (bpm) (Arm B), or 60 seconds delay in VT zone 170-199 bpm (Arm C), compared to 2.5 seconds delay at 170 bpm (Arm A) among black and white patients. RESULTS: MADIT-RIT enrolled 272 (20%) black and 1119 (80%) white patients. The risk of inappropriate therapy was similar among blacks and whites, HR 1.25, 95% CI (0.82-1.93), P  =  0.30. High rate cut-off or delayed VT therapy was associated with significant reductions in inappropriate therapy among whites, Arm B versus Arm A, HR 0.15, 95% CI (0.08-0.29), P < 0.0001, Arm C versus Arm A, HR 0.19, 95% CI (0.11-0.33), P < 0.001, and black individuals Arm B versus Arm A, HR 0.24, 95% CI (0.01-0.56), P  =  0.0001, Arm C versus Arm A, HR 0.30, 95% CI (0.13-0.68), P  =  0.004, P interaction > 0.10). However, delayed VT therapy was associated with a trend toward greater reduction in appropriate therapy in black individuals, HR 0.08, 95% CI (0.03-0.27), P < 0.0001 relative to white individuals, HR 0.27, 95% CI (0.16-0.43), P < 0.0001, P interaction  =  0.077. CONCLUSION: In MADIT-RIT, high rate and delayed detection ICD programming provided similar benefit with reductions in both inappropriate therapy and unnecessary appropriate therapy among black and white individuals. CLINICALTRIALS. GOV IDENTIFIER: NCT00947310.


Asunto(s)
Población Negra , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Disparidades en Atención de Salud/etnología , Taquicardia Ventricular/terapia , Población Blanca , Potenciales de Acción , Negro o Afroamericano , Cardioversión Eléctrica/efectos adversos , Europa (Continente)/epidemiología , Femenino , Frecuencia Cardíaca , Humanos , Israel/epidemiología , Japón/epidemiología , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , América del Norte/epidemiología , Diseño de Prótesis , Falla de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etnología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Procedimientos Innecesarios
3.
J Cardiovasc Electrophysiol ; 29(7): 1017-1023, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29846992

RESUMEN

INTRODUCTION: Adverse electrical remodeling (AER), represented here as the sum absolute QRST integral (SAI QRST), has previously been shown to be directly associated with the risk for ventricular arrhythmia (VA). Cardiac resynchronization therapy (CRT) is known to reduce the risk for VA through various mechanisms, including reverse remodeling, and we aimed to evaluate the association between baseline AER and the risk for VA in CRT recipients. METHODS AND RESULTS: The study population comprised 961 CRT-D implanted patients from the MADIT CRT study. The relationship between SAI QRST, VA risk, and VA risk/death was evaluated as a continuous and as a categorical variable-tertiles (T1 ≤ 0.527, T2 0.528-0.766, T3 > 0.766). In a multivariable model, AER was inversely associated with the risk of VA. Each unit increase in SAI QRST was associated with 64% (P  =  0.007) and 54% (P  =  0.003) decrease in the risk of VA and VA/death, respectively. Patients with high SAI QRST (T3) and medium SAI QRST (T2) had 52% (P < 0.001) and 32% (P  =  0.027) reduced risk for VA and 44% (P  =  0.002) and 26% (P  =  0.055) reduced risk for VA/death as compared with patients with low SAI QRST (T1), respectively. CONCLUSION: In CRT implanted patients with mild heart failure, baseline AER was inversely associated with the risk for VA and VA/death; this is a finding that contradicts the relationship previously reported in non-CRT implanted patients. We theorize that CRT may abate the process of AER; however, characterization of this mechanism requires further study.


Asunto(s)
Remodelación Atrial/fisiología , Terapia de Resincronización Cardíaca/efectos adversos , Cardiomiopatías/fisiopatología , Cardiomiopatías/terapia , Desfibriladores Implantables/efectos adversos , Taquicardia Ventricular/fisiopatología , Anciano , Terapia de Resincronización Cardíaca/métodos , Cardiomiopatías/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología
4.
Europace ; 20(FI2): f225-f232, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29905788

RESUMEN

Aims: Data on outcomes in patients using the wearable cardioverter-defibrillator (WCD) > 90 days are limited. We aimed to analyse the clinical course of patients with WCD use ≤90 days vs. WCD use >90 days. Methods and results: We assessed arrhythmia events during WCD use, and ejection fraction (EF) improvement/implantable cardioverter-defibrillator (ICD) implantation at the end of WCD use in patients with WCD use ≤90 days vs. WCD use >90 days enrolled in the WEARIT-II registry, further assessed by disease aetiology (ischaemic vs. non-ischaemic vs. congenital/inherited heart disease). There were 981 (49%) patients with WCD use >90 days, and 1019 patients with WCD use ≤90 days (median 120 vs. 55 days). There was a lower incidence of sustained ventricular tachycardia/ventricular fibrillation (VT/VF) events (11 vs. 50 events per 100 patient-years, P < 0.001), WCD treated VT/VF events (1 vs. 8 events per 100 patient-years, P < 0.001), and non-sustained VT events (21 vs. 51 events per 100 patient-years, P = 0.008) with WCD use >90 vs. WCD use ≤90 days. Non-ischaemic cardiomyopathy patients presented with similar rates of sustained VT/VF events during WCD use >90 vs. ≤90 days (13.4 vs. 13.7 events per 100 patient-years, P = 0.314), while most of these events terminated spontaneously. One-third of the patients with extended WCD use further improved their EF and they were not implanted with an ICD, with similar rates among ischaemic and non-ischaemic patients. Conclusions: In WEARIT-II, patients with extended WCD use >90 days remain at risk for ventricular arrhythmia events. One-third of the patients with WCD use >90 days further improved their EF, avoiding the need to consider ICD implantation.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores , Cardioversión Eléctrica/instrumentación , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Dispositivos Electrónicos Vestibles , Anciano , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/complicaciones , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/mortalidad
5.
Europace ; 20(5): 794-800, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28398490

RESUMEN

Aims: Discordant and concordant left bundle branch block (dLBBB/cLBBB) are characterized by negative or positive T waves, respectively, in lateral leads. We assessed if the two morphologies are associated with different clinical status and prognosis in patients with heart failure (HF) and current indication to Cardiac Resynchronization Therapy (CRT)/CRT-Defibrillator (CRT-D). Methods and results: Baseline electrocardiograms of 1270 patients with LBBB in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy cohort were analysed to identify dLBBB and cLBBB. The two groups were compared with respect to baseline clinical characteristics, primary endpoint (HF event or death), and secondary endpoint (ventricular tachycardia, ventricular fibrillation, or death) over a 3.5-year period, and benefit of CRT-D over implantable cardioverter defibrillator (ICD). dLBBB was identified in 909 (72%) patients, and cLBBB in 361 (28%). Patients with dLBBB were older, had more severe symptoms and systolic dysfunction, as well as higher brain natriuretic peptide. CRT-D was superior to ICD in patients with both LBBB morphologies. The occurrence of the primary outcome was significantly more frequent in patients with dLBBB than in those with cLBBB, both in the entire cohort (P = 0.005), and in the CRT-D arm (P = 0.002). There was a trend towards more frequent occurrence of the secondary endpoint in patients with dLBBB than in those with cLBBB, but statistical significance was not reached in the whole population or in the subgroup undergoing CRT-D. Among patients receiving CRT-D, dLBBB was an independent predictor of the primary endpoint. Conclusion: dLBBB morphology is associated with more severe HF clinical status and worse prognosis, even in patients receiving CRT-D, compared with cLBBB morphology.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Desfibriladores Implantables/estadística & datos numéricos , Insuficiencia Cardíaca , Anciano , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Dispositivos de Terapia de Resincronización Cardíaca , Electrocardiografía/métodos , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Humanos , Italia , Masculino , Persona de Mediana Edad , Mortalidad , Evaluación de Resultado en la Atención de Salud , Pronóstico , Factores de Riesgo , Índice de Severidad de la Enfermedad
6.
Pacing Clin Electrophysiol ; 41(10): 1307-1313, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29992590

RESUMEN

BACKGROUND: The WEARIT-II Registry demonstrated efficacy and safety of the wearable cardioverter defibrillator (WCD) for at-risk cardiac patients. However, 1-year outcomes in this population have not been reported. METHODS: The WEARIT-II Registry enrolled 2,000 U.S. patients prescribed the WCD. One-year mortality data from start of WCD use were prospectively collected for 1,846 patients (93%). Outcome data were analyzed by disease etiology and implantable cardioverter defibrillator (ICD) implantation following WCD use. RESULTS: During 12 months of follow-up, 73 patients died (4%). Kaplan-Meier survival analysis showed differences in all-cause mortality from WCD prescription between patients with ischemic versus nonischemic cardiomyopathy versus congenital/inherited heart disease (4% vs 3% vs 7%, P = 0.013). Patients with ventricular arrhythmia events during WCD use had a higher 1-year mortality (10% vs 3%, P = 0.042). Renal disease, increasing age, prior syncope, and nonbeta-blocker use predicted mortality. One-year mortality was similar in patients who did versus did not receive an ICD following WCD use in ischemic (3% vs 4%, P = 0.470) and nonischemic cardiomyopathy (3% vs 3%, P = 0.892). Patients with congenital/inherited heart disease with no implanted ICD had a trend toward a higher rate of mortality than those who received an ICD (8% vs 3%, P = 0.082). Multivariate models confirmed these findings. CONCLUSION: One-year follow-up from the WEARIT-II Registry shows an overall good survival in patients prescribed the WCD. Short-term use of WCD allows appropriate risk stratification for decision on an ICD implantation in at-risk ischemic and nonischemic cardiomyopathy patients. Congenital/inherited heart disease patients had a higher risk of 1-year mortality even without an implanted ICD post-WCD.


Asunto(s)
Enfermedades Cardiovasculares/terapia , Cardioversión Eléctrica/instrumentación , Dispositivos Electrónicos Vestibles , Anciano , Enfermedades Cardiovasculares/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Análisis de Supervivencia , Resultado del Tratamiento , Estados Unidos
7.
Ann Noninvasive Electrocardiol ; 23(3): e12537, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29504689

RESUMEN

BACKGROUND: A comprehensive report on the clinical course of the three major genotypes of the long QT syndrome (LQTS) in a large U.S. patient cohort is lacking. METHODS: Our study consisted of 1,923 U.S. subjects from the Rochester-based LQTS Registry with genotype-positive LQT1 (n = 879), LQT2 (n = 807), and LQT3 (n = 237). We evaluated the risk of a first cardiac event (syncope, aborted cardiac arrest, or sudden cardiac death, whichever occurred first) from birth through age 50 years. Cox proportional hazards regression models incorporating clinical covariates were used to assess genotype-specific risk of cardiac events. RESULTS: For all three genotypes, the cumulative probability of a first cardiac event increased most markedly during adolescence. Multivariate analysis identified proband status and QTc > 500 ms as predictors of cardiac events in all three genotypes, and males <14 years and females >14 years as predictors of cardiac events in LQT1 and LQT2 only. Beta-blockers significantly reduced the risk of cardiac events in LQT1 (HR: 0.49, p = .002) and LQT2 patients (HR: 0.48, p = .001). A trend toward beta-blocker benefit in reducing cardiac events was found in LQT3 females (HR: 0.32, p = .078), but not in LQT3 males (HR: 1.37, p = .611). CONCLUSION: Risk factors and outcomes in LQTS patients varied by genotype. In all three genotypes, proband status and prolonged QTc were risk factors for cardiac events. Younger males and older females experienced increased risk in LQT1 and LQT2 only. Beta-blockers were most effective in reducing cardiac events in LQT1 and LQT2, with a potential benefit in LQT3 females.


Asunto(s)
Electrocardiografía , Genotipo , Síndrome de QT Prolongado/genética , Síndrome de QT Prolongado/fisiopatología , Adolescente , Adulto , Factores de Edad , Niño , Preescolar , Estudios de Cohortes , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , New York , Modelos de Riesgos Proporcionales , Sistema de Registros , Factores de Riesgo , Factores Sexuales , Adulto Joven
8.
Ann Noninvasive Electrocardiol ; 23(2): e12491, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28940909

RESUMEN

BACKGROUND: Frequent ventricular ectopy on preimplantation Holter has been associated with attenuated benefit from cardiac resynchronization therapy (CRT). However, it is unclear whether ectopic burden measured post-CRT implantation can be utilized to evaluate long-term prognosis. We aimed to describe the association between post-CRT implantation ectopic burden and subsequent risk of clinical outcomes. METHODS: At the 12-month follow-up visit, 24-hour Holter recordings were performed in 698 CRT-D patients from the MADIT-CRT study. The mean number of ventricular premature complexes (VPCs/hour) was calculated. High ectopic burden was defined as >10 VPCs/hour and low burden as ≤10 VPCs/hour. Multivariate Cox proportional hazards models were utilized to assess the association between 12-month ectopic burden and the risk of the end points of heart failure (HF) or death and ventricular tachyarrhythmias (VT/VF). RESULTS: At 12 months, 282 (40%) patients presented with low ectopic burden and 416 (60%) patients presented with high ectopic burden. The 3-year risk of HF/death and VT/VF was lower in patients with a low burden (7% and 8%) and significantly higher (25% and 24%) in patients with high burden. In multivariate analyses, patients with a high ectopic burden had approximately threefold increased risk of both HF/death (HR=2.76 [1.62-4.70], p < .001) and VT/VF (HR=2.79 [1.69-4.58], p < .001). CONCLUSION: In CRT-D patients with mild heart failure, high ectopic burden at 12-month follow-up was associated with a high 3-year risk of HF/death and VT/VF and threefold increased risk as compared to patients with low burden. Ectopic burden at 12 months may be a valuable approach for evaluating long-term prognosis.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Electrocardiografía Ambulatoria/métodos , Insuficiencia Cardíaca/mortalidad , Fibrilación Ventricular/mortalidad , Complejos Prematuros Ventriculares/diagnóstico por imagen , Complejos Prematuros Ventriculares/epidemiología , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Electrocardiografía/métodos , Femenino , Insuficiencia Cardíaca/etiología , Humanos , Incidencia , Internacionalidad , Masculino , Persona de Mediana Edad , Pronóstico , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/terapia , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Complejos Prematuros Ventriculares/etiología
9.
Circulation ; 134(12): 872-82, 2016 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-27566755

RESUMEN

BACKGROUND: Risk stratification in patients with type 3 long-QT syndrome (LQT3) by clinical and genetic characteristics and effectiveness of ß-blocker therapy has not been studied previously in a large LQT3 population. METHODS: The study population included 406 LQT3 patients with 51 sodium channel mutations; 391 patients were known to be event free during the first year of life and were the focus of our study. Clinical, electrocardiographic, and genetic parameters were acquired for patients from 7 participating LQT3 registries. Cox regression analysis was used to evaluate the independent contribution of clinical, genetic, and therapeutic factors to the first occurrence of time-dependent cardiac events (CEs) from age 1 to 41 years. RESULTS: Of the 391 patients, 118 (41 males, 77 females) patients (30%) experienced at least 1 CE (syncope, aborted cardiac arrest, or long-QT syndrome-related sudden death), and 24 (20%) suffered from LQT3-related aborted cardiac arrest/sudden death. The risk of a first CE was directly related to the degree of QTc prolongation. Cox regression analysis revealed that time-dependent ß-blocker therapy was associated with an 83% reduction in CEs in females (P=0.015) but not in males (who had many fewer events), with a significant sex × ß-blocker interaction (P=0.04). Each 10-ms increase in QTc duration up to 500 ms was associated with a 19% increase in CEs. Prior syncope doubled the risk for life-threatening events (P<0.02). CONCLUSIONS: Prolonged QTc and syncope predispose patients with LQT3 to life-threatening CEs. However, ß-blocker therapy reduces this risk in females; efficacy in males could not be determined conclusively because of the low number of events.


Asunto(s)
Síndrome de QT Prolongado/tratamiento farmacológico , Adolescente , Antagonistas Adrenérgicos beta/uso terapéutico , Adulto , Trastorno del Sistema de Conducción Cardíaco , Niño , Preescolar , Electrocardiografía/métodos , Femenino , Paro Cardíaco/tratamiento farmacológico , Paro Cardíaco/etiología , Humanos , Lactante , Síndrome de QT Prolongado/diagnóstico , Masculino , Sistema de Registros , Medición de Riesgo , Caracteres Sexuales , Canales de Sodio/genética , Síncope/complicaciones , Síncope/tratamiento farmacológico , Adulto Joven
10.
N Engl J Med ; 370(18): 1694-701, 2014 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-24678999

RESUMEN

BACKGROUND: The Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT) showed that early intervention with cardiac-resynchronization therapy with a defibrillator (CRT-D) in patients with an electrocardiographic pattern showing left bundle-branch block was associated with a significant reduction in heart-failure events over a median follow-up of 2.4 years, as compared with defibrillator therapy alone. METHODS: We evaluated the effect of CRT-D on long-term survival in the MADIT-CRT population. Post-trial follow-up over a median period of 5.6 years was assessed among all 1691 surviving patients (phase 1) and subsequently among 854 patients who were enrolled in post-trial registries (phase 2). All reported analyses were performed on an intention-to-treat basis. RESULTS: At 7 years of follow-up after initial enrollment, the cumulative rate of death from any cause among patients with left bundle-branch block was 18% among patients randomly assigned to CRT-D, as compared with 29% among those randomly assigned to defibrillator therapy alone (adjusted hazard ratio in the CRT-D group, 0.59; 95% confidence interval [CI], 0.43 to 0.80; P<0.001). The long-term survival benefit of CRT-D in patients with left bundle-branch block did not differ significantly according to sex, cause of cardiomyopathy, or QRS duration. In contrast, CRT-D was not associated with any clinical benefit and possibly with harm in patients without left bundle-branch block (adjusted hazard ratio for death from any cause, 1.57; 95% CI, 1.03 to 2.39; P=0.04; P<0.001 for interaction of treatment with QRS morphologic findings). CONCLUSIONS: Our findings indicate that in patients with mild heart-failure symptoms, left ventricular dysfunction, and left bundle-branch block, early intervention with CRT-D was associated with a significant long-term survival benefit. (Funded by Boston Scientific; ClinicalTrials.gov numbers, NCT00180271, NCT01294449, and NCT02060110.).


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Anciano , Bloqueo de Rama/complicaciones , Terapia Combinada , Desfibriladores Implantables , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/prevención & control , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Índice de Severidad de la Enfermedad , Volumen Sistólico , Disfunción Ventricular Izquierda/complicaciones
11.
Am Heart J ; 189: 75-84, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28625384

RESUMEN

Effects of implantable cardioverter/defibrillator (ICD) shocks and antitachycardia pacing (ATP) on anxiety and quality of life (QoL) in ICD patients are poorly understood. METHODS: We evaluated changes in QoL from baseline to 9-month follow-up using the EQ-5D questionnaire in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) (n=1,268). We assessed anxiety levels using the Florida Shock Anxiety Scale (1-10 score) in patients with appropriate or inappropriate shocks or ATP compared to those with no ICD therapy during the first 9 months postimplant. The analysis was stratified by number of ATP or shocks (0-1 vs ≥2) and adjusted for covariates. RESULTS: In MADIT-RIT, 15 patients (1%) had ≥2 appropriate shocks, 38 (3%) had ≥2 appropriate ATPs. Two or more inappropriate shocks were delivered in 16 patients (1%); ≥2 inappropriate ATPs, in 70. In multivariable analysis, patients with ≥2 appropriate shocks had higher levels of shock-related anxiety than those with ≤1 appropriate shock (P<.01). Furthermore, ≥2 inappropriate shocks produced more anxiety than ≤1 inappropriate shock (P=.005). Consistently, ≥2 appropriate ATPs resulted in more anxiety than ≤1 (P=.028), whereas the number of inappropriate ATPs showed no association with anxiety levels (P=.997). However, there was no association between QoL and appropriate or inappropriate ATP/shock (all P values > .05). CONCLUSIONS: In MADIT-RIT, ≥2 appropriate or inappropriate ICD shocks and ≥2 appropriate ATPs are associated with more anxiety at 9-month follow-up despite no significant changes in the assessment of global QoL by the EQ-5D questionnaire. Innovative ICD programming reducing inappropriate therapies may help deal with patient concerns about the device.


Asunto(s)
Ansiedad/etiología , Desfibriladores Implantables , Calidad de Vida , Taquicardia Ventricular/terapia , Ansiedad/psicología , Cardioversión Eléctrica/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Encuestas y Cuestionarios , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/psicología , Factores de Tiempo , Resultado del Tratamiento
12.
Am Heart J ; 189: 158-166, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28625372

RESUMEN

Patients with diabetes mellitus, prior myocardial infarction, older age, and a relatively preserved left ventricular ejection fraction remain at risk for sudden cardiac death that is potentially amenable by the subcutaneous implantable cardioverter defibrillator with a good risk-benefit profile. The launched MADIT S-ICD study is designed to test the hypothesis that post-myocardial infarction diabetes patients with relatively preserved ejection fraction of 36%-50% will have a survival benefit from a subcutaneous implantable cardioverter defibrillator.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Infarto del Miocardio/complicaciones , Anciano , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Estudios Prospectivos , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Estados Unidos/epidemiología
13.
Am Heart J ; 191: 21-29, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28888266

RESUMEN

BACKGROUND: Primary prevention implantable cardioverter defibrillator (ICD) reduce all-cause mortality by reducing sudden cardiac death. There are conflicting data regarding whether patients with more advanced heart failure derive ICD benefit owing to the competing risk of nonsudden death. METHODS: We performed a patient-level meta-analysis of New York Heart Association (NYHA) class II/III heart failure patients (left ventricular ejection fraction ≤35%) from 4 primary prevention ICD trials (MADIT-I, MADIT-II, DEFINITE, SCD-HeFT). Bayesian-Weibull survival regression models were used to assess the impact of NYHA class on the relationship between ICD use and mortality. RESULTS: Of the 2,763 patients who met study criteria, 68% (n=1,867) were NYHA II and 52% (n=1,435) were randomized to an ICD. In a multivariable model including all study patients, the ICD reduced mortality (hazard ratio [HR] 0.65, 95% posterior credibility interval [PCI]) 0.40-0.99). The interaction between NYHA class and the ICD on mortality was significant (posterior probability of no interaction=.036). In models including an interaction term for the NYHA class and ICD, the ICD reduced mortality among NYHA class II patients (HR 0.55, PCI 0.35-0.85), and the point estimate suggested reduced mortality in NYHA class III patients (HR 0.76, PCI 0.48-1.24), although this was not statistically significant. CONCLUSIONS: Primary prevention ICDs reduce mortality in NYHA class II patients and trend toward reducing mortality in the heterogeneous group of NYHA class III patients. Improved risk stratification tools are required to guide patient selection and shared decision making among NYHA class III primary prevention ICD candidates.


Asunto(s)
Cardiología , Muerte Súbita Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Prevención Primaria/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Sociedades Médicas , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Salud Global , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Humanos , New York , Tasa de Supervivencia/tendencias
14.
J Cardiovasc Electrophysiol ; 28(7): 778-784, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28429542

RESUMEN

INTRODUCTION: The wearable cardioverter defibrillator (WCD) may allow stabilization until reassessment for an implantable cardioverter defibrillator (ICD) among high-risk heart failure (HF) patients. However, there are limited data on the WCD benefit in the acute decompensated HF setting. METHODS AND RESULTS: The Study of the Wearable Cardioverter Defibrillator in Advanced Heart Failure Patients (SWIFT) was a prospective clinical trial carried out at two medical centers. Patients hospitalized with advanced HF symptoms and reduced left ventricular ejection function (LVEF) were enrolled and prescribed a WCD prior to discharge for a total of 3 months. Outcome measures included arrhythmic events, WCD discharge, and death. Study patients (n = 75, mean age 51 ± 14 years, 31% women) had a mean LVEF of 21.5 ± 10.4%. Non-ischemic cardiomyopathy was present in 66% of patients. The median WCD wearing time was 59 (interquartile range 17-97) days, and 80% of patients wore the device >50% of daily hours. WCD interrogations showed a total of 8 arrhythmic events in 5 patients, including 3 nonsustained or self-terminating ventricular tachycardia (VT) events, and one polymorphic VT successfully terminated by the WCD. None of the patients died while wearing the device and no inappropriate device therapies occurred. Upon termination of treatment with the WCD, 21 patients (28%) received an ICD. At 3 years, the cumulative death rate was 20% in the ischemic and 21% in non-ischemic cardiomyopathy patients. CONCLUSION: A management strategy incorporating the WCD can be safely used to bridge the decision regarding the need for ICD implantation in high-risk patients with advanced HF.


Asunto(s)
Desfibriladores/tendencias , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/tendencias , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Adulto , Anciano , Estudios de Cohortes , Desfibriladores Implantables/tendencias , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
15.
J Cardiovasc Electrophysiol ; 28(1): 94-102, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27696593

RESUMEN

INTRODUCTION: Approximately 10-20% of ICD recipients receive inappropriate device therapies. The purpose of this study was to compare the frequency of inappropriate therapies (IT) between men and women enrolled in MADIT II and MADIT-CRT, and assess for potential adverse outcomes. METHODS: The electrograms for each ICD or CRT-D therapy, defined as either ATP or shock, were reviewed by adjudication committees for both studies. ICD therapy was considered inappropriate if it was delivered for reasons other than VT/VF. The rhythm triggering IT was categorized as atrial fibrillation/flutter, SVT, or inappropriate sensing when possible. RESULTS: One thousand nine hundred and fifty-four men and 556 women received ICD or CRT-D devices. The risk of IT was significantly lower in women than men (9.2% vs. 13.5%, P = 0.006). The most common cause of IT in men was atrial fibrillation (38%) and SVT in women (43%). Inappropriate shock was not associated with increased mortality in either women (HR 0.82 [95% CI 0.11-6.08]; P = NS) or men (HR 1.37 [95% CI 0.75-2.48]; P = NS) by multivariate analysis. Conversely, appropriate shock therapy strongly correlated with increased risk of death during subsequent post-shock follow-up in women (HR 5.99 [95% CI 2.75-13.02]; P < 0.0001) and men (HR 2.61 [95% CI 1.82-3.74]; P < 0.0001). CONCLUSIONS: Women experience significantly less IT than men, partially explained by the increased frequency of atrial fibrillation in men. IT was not associated with increased mortality in either sex. Appropriate shock therapy was a strong predictor of death in both, with women showing a 2-fold higher risk than men during post-shock long-term follow-up.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Falla de Prótesis , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Aleteo Atrial/diagnóstico , Aleteo Atrial/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Factores Sexuales , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/fisiopatología
16.
J Cardiovasc Electrophysiol ; 28(11): 1345-1351, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28744959

RESUMEN

BACKGROUND: No precise tools exist to predict appropriate shocks in patients with a primary prevention ICD. We sought to identify characteristics predictive of appropriate shocks in patients with a primary prevention implantable cardioverter defibrillator (ICD). METHODS: Using patient-level data from the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) and the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), we identified patients with any appropriate shock. Clinical and demographic variables were included in a logistic regression model to predict appropriate shocks. RESULTS: There were 1,463 patients randomized to an ICD, and 285 (19%) had ≥1 appropriate shock over a median follow-up of 2.59 years. Compared with patients without appropriate ICD shocks, patients who received any appropriate shock tended to have more severe heart failure. In a multiple logistic regression model, predictors of appropriate shocks included NYHA class (NYHA II vs. I: OR 1.65, 95% CI 1.07-2.55; NYHA III vs. I: OR 1.74, 95% CI 1.10-2.76), lower LVEF (per 1% change) (OR 1.04, 95% CI 1.02-1.06), absence of beta-blocker therapy (OR 1.61, 95% CI 1.23-2.12), and single chamber ICD (OR 1.67, 95% CI 1.13-2.45). CONCLUSION: In this meta-analysis of patient level data from MADIT-II and SCD-HeFT, higher NYHA class, lower LVEF, no beta-blocker therapy, and single chamber ICD (vs. dual chamber) were significant predictors of appropriate shocks.


Asunto(s)
Desfibriladores Implantables/tendencias , Electrochoque/tendencias , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Anciano , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto/métodos , Valor Predictivo de las Pruebas , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos , Factores de Riesgo
17.
Europace ; 19(9): 1549-1555, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28339581

RESUMEN

AIMS: There is lack of conclusive evidence from randomized clinical trials on the efficacy and safety of upgrade to cardiac resynchronization therapy (CRT) in patients with implanted pacemakers (PM) or defibrillators (ICD) with reduced left ventricular ejection fraction (LVEF) and chronic heart failure (HF). The BUDAPEST-CRT Upgrade Study was designed to compare the efficacy and safety of CRT upgrade from conventional PM or ICD therapy in patients with intermittent or permanent right ventricular (RV) septal/apical pacing, reduced LVEF, and symptomatic HF. METHODS AND RESULTS: The BUDAPEST-CRT study is a prospective, randomized, multicentre, investigator-sponsored clinical trial. A total of 360 subjects will be enrolled with LVEF ≤ 35%, NYHA functional classes II-IVa, paced QRS ≥ 150 ms, and a RV pacing ≥ 20%. Patients will be followed for 12 months. Randomization is performed in a 3:2 ratio (CRT-D vs. ICD). The primary composite endpoint is all-cause mortality, a first HF event, or less than 15% reduction in left ventricular (LV) end-systolic volume at 12 months. Secondary endpoints are all-cause mortality, all-cause mortality or HF event, and LV volume reduction at 12 months. Tertiary endpoints include changes in quality of life, NYHA functional class, 6 min walk test, natriuretic peptides, and safety outcomes. CONCLUSION: The results of our prospective, randomized, multicentre clinical trial will provide important information on the role of cardiac resynchronization therapy with defibrillator (CRT-D) upgrade in patients with symptomatic HF, reduced LVEF, and wide-paced QRS with intermittent or permanent RV pacing. CLINICAL TRIALS.GOV IDENTIFIER: NCT02270840.


Asunto(s)
Estimulación Cardíaca Artificial , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca/terapia , Marcapaso Artificial , Volumen Sistólico , Función Ventricular Izquierda , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/mortalidad , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Enfermedad Crónica , Protocolos Clínicos , Remoción de Dispositivos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Europa (Continente) , Tolerancia al Ejercicio , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Israel , Estudios Prospectivos , Recuperación de la Función , Proyectos de Investigación , Factores de Tiempo , Resultado del Tratamiento , Prueba de Paso
18.
Pacing Clin Electrophysiol ; 40(12): 1405-1411, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29052236

RESUMEN

BACKGROUND: The effects of heart failure (HF) severity on risk of inappropriate implantable cardioverter-defibrillator (ICD) therapy have not been thoroughly investigated. We aimed to study the association between HF severity and inappropriate ICD therapy in MADIT-RIT. METHODS: MADIT-RIT randomized 1,500 patients to three ICD programming arms: conventional (Arm A), high-rate cut-off (Arm B: ≥200 beats/min), and delayed therapy (Arm C: 60-second delay for ≥170 beats/min). We evaluated the association between New York Heart Association (NYHA) class III (n = 256) versus class I-II (n = 251) and inappropriate ICD therapy in Arm A patients with ICD-only and cardiac resynchronization therapy with defibrillator (CRT-D). We additionally assessed benefit of novel ICD programming in Arms B and C versus Arm A by NYHA classification. RESULTS: In Arm A, the risk of inappropriate therapy was significantly higher in those with NYHA III versus NYHA I-II for both ICD (hazard ratio [HR] = 2.55, confidence interval [CI]: 1.51-4.30, P < 0.001) and CRT-D patients (HR = 3.73, CI: 1.14-12.23, P = 0.030). This was consistent for inappropriate ATP and inappropriate ICD therapy < 200 beats/min, but not for inappropriate shocks. Novel ICD programming significantly reduced inappropriate therapy in patients with both NYHA III (Arm B vs Arm A: HR = 0.08, P < 0.001; Arm C vs Arm A: HR = 0.17, P < 0.001) and NYHA I-II (Arm B vs Arm A: HR = 0.25, P < 0.001; Arm C vs Arm A: HR = 0.28, P < 0.001). CONCLUSION: Patients with more severe HF are at increased risk for inappropriate ICD therapy, particularly ATP due to arrhythmias < 200 beats/min. Novel programming with high-rate cut-off or delayed detection reduces inappropriate ICD therapies in both mild and moderate HF.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Femenino , Humanos , Masculino , Uso Excesivo de los Servicios de Salud , Persona de Mediana Edad , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
19.
Pacing Clin Electrophysiol ; 40(1): 9-16, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27808410

RESUMEN

BACKGROUND: Weight loss has been associated with adverse outcomes among heart failure (HF) patients, including those receiving cardiac resynchronization therapy with defibrillator (CRT-D). The effect of significant weight change on inappropriate implantable cardioverter-defibrillator (ICD) therapy among CRT-D patients is not well understood. METHODS: We evaluated the impact of significant weight change at 1 year on subsequent inappropriate ICD therapy during follow-up among 993 CRT-D patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy. Patients were divided into three subgroups based on weight change at 1 year after enrollment: weight loss (weight loss ≥ 5%), weight gain (weight gain ≥ 5%), and stable weight (weight loss and weight gain < 5%). The primary end point was inappropriate ICD therapy. Secondary end point included inappropriate ICD therapy related to supraventricular arrhythmias (SVAs). RESULTS: There were 102 (10.3%) patients who experienced weight loss, 689 (69.4%) whose weight was stable, and 202 (20.3%) who gained weight at 1 year. Patients with weight loss had increased risk of subsequent inappropriate ICD therapy relative to patients with stable weight (hazard ratio [HR] = 2.35, 95% confidence interval [CI]: 1.39-3.98, P = 0.001) or weight gain (HR = 2.27, 95% CI: 1.18-4.38, P = 0.014). Furthermore, patients losing weight were at greater risk of subsequent inappropriate ICD therapy related to SVAs when compared to patients with stable weight (HR = 2.16, 95% CI: 1.18-3.95, P = 0.013) or weight gain (HR = 2.02, 95% CI: 0.95-4.29, P = 0.068). CONCLUSION: In mild HF patients receiving CRT-D, significant weight loss at 1 year is associated with increased risk of subsequent inappropriate ICD therapy, including risk related to SVAs.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Traumatismos por Electricidad/epidemiología , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/prevención & control , Obesidad/epidemiología , Delgadez/epidemiología , Anciano , Causalidad , Comorbilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Medición de Riesgo , Resultado del Tratamiento , Estados Unidos/epidemiología
20.
Artículo en Inglés | MEDLINE | ID: mdl-27572179

RESUMEN

AIMS: Strict left bundle branch block (LBBB) criteria were recently proposed to identify LBBB patients to benefit most from cardiac resynchronization therapy (CRT). The aim of our study was to automate identification of strict LBBB in order to facilitate its broader application. METHODS: We developed a series of algorithms to automatically detect and measure parameters required for strict LBBB criteria and proposed a definition of QRS notch detection. The algorithms were developed using training (n = 20) and validation (n = 592) sets consisting of signal-averaged 12-lead ECGs (1,000 Hz sampling) recorded from 612 LBBB patients from Multicenter Automatic Defibrillator Implantation Trial-CRT. Four trained clinicians independently performed adjudication on 148 different ECGs for comparing automatic and manually adjudicated results, in addition to 13 ECGs for evaluation of intraobserver variability and 32 ECGs for interobserver variability. We assessed the performance of the automated algorithms using manually adjudicated ECGs as references. RESULTS: Overall sensitivity and specificity for detecting strict LBBB were 95% and 86%, respectively. The mean absolute deviation (MAD) of QRS duration and notch/slur locations for the automated method versus the manual method was below 1 ms, and MAD values were lower than 2 ms for interobserver and intraobserver variability. Sensitivity and specificity for detecting notch and slur locations were 87% and 96% for notches and 78% and 90% for slurs using the automatic method. In addition 95% and 93% agreements for notches and 90% and 88% agreements for slurs were reached for intra- and interobserver. CONCLUSION: The proposed algorithms automatically measure QRS features for the diagnosis of strict LBBB. Our study shows good performance in reference to manual results.


Asunto(s)
Bloqueo de Rama/diagnóstico , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA