Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 90(6): 890-897, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-28544186

RESUMEN

OBJECTIVES: The French Ebiomatrix registry aimed to confirm the results of the Leaders trial in an all-comer population in France. BACKGROUND: The Leaders trial showed the Biolimus-eluting-sent (BES) to be equivalent to the Cypher stent in terms of safety and efficacy at 1 year and superior regarding stent thrombosis after 1 year. METHODS: BES recipients were enrolled in 42 French centers with up to 24-month clinical follow up. RESULTS: 2365 patients were included. Mean age: 65.7 ±11.2 years, 76.1% males, 31.8% had diabetes, 36.5% ACS (28.7% non-ST-elevation MI and 7.8% with ST-elevation MI). 1.7 ± 1.0 stents/patient were implanted and procedural success was 99.5%. 12-month follow-up was completed in 94.3% patients and 24 months in 91.4%. MACCE rates at 12 and 24 months were 5.8% and 9% (all cause-death 1.5% and 2.2%; stent thrombosis definite/probable 0.4% and 0.6%), respectively. MACCE were not significantly higher in diabetic patients compared with non-diabetics but cardiac death was higher (1.6% vs. 0.6%, P = 0.01 at 1 year and 1.9% vs. 0.6, P = 0.005 at 2 years) as was stent thrombosis (0.9% vs. 0.2%, P = 0.009 and 1.2 vs. 0.3% P = 0.008). Compared with non-ACS patients, MACCE was significantly higher in the ACS subgroup (7.5% vs. 4.8%, P = 0.001 at 1 year and 10.3% vs.8.1%, P = 0.07 at 2 years). CONCLUSION: In this large real-world registry, the BES with biodegradable polymer showed excellent acute and mid-term outcomes with a 5.8% and 9% rate of MACCE at one and 2 years and a very low rate of stent thrombosis between 1 and 2 years (0.2%), thus demonstrating the replicability of the LEADERS trial in a registry population. © 2017 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Complicaciones Posoperatorias/epidemiología , Sistema de Registros , Implantes Absorbibles , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Incidencia , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 88(3): 358-66, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26650913

RESUMEN

OBJECTIVES: This observational study assessed the 9-month clinical outcomes in an « all comers ¼ population with a focus on patients with atrial fibrillation (AF) after thin strut bare metal stenting. BACKGROUND: Drug eluting stent (DES) implantation is the treatment of choice for coronary artery disease (CAD) leaving only marginal indications for the use of bare metal stents (BMS). However, selected treatment populations with DES contraindications such as patients who cannot sustain 6-12 months of dual antiplatelet therapy (DAPT) remain candidates for BMS implantations. METHODS: Thin strut bare metal stenting in a priori defined subgroups were investigated in a non-randomized, international, multicenter «all comers¼ observational study. Primary endpoint was the 9-month TLR rate whereas secondary endpoints included the 9-month MACE and procedural success rates. RESULTS: A total of 783 patients of whom 98 patients had AF underwent BMS implantation. Patient age was 70.4 ± 12.8 years. Cardiovascular risk factors in the overall population were male gender (78.2%, 612/783), diabetes (25.2%, 197/783), hypertension (64.1%, 502/783), cardiogenic shock (4.9%, 38/783) and end stage renal disease (4.9%, 38/783). In-hospital MACE was 4.1% (30/783) in the overall population. The 9-month TLR rate was 4.5% (29/645) in the non-AF group and 3.3% (3/90) in the AF group (P = 0.613). At 9 months, the MACE rate in the AF-group and non-AF group was not significantly different either (10.7%, 69/645 vs. 6.7%, 6/90; P = 0.237). Accumulated stroke rates were 0.3% (2/645) in the non-AF subgroup at baseline and 1.1% (1/90) in the AF subgroup (P = 0.264). CONCLUSION: Bare metal stenting in AF patients delivered acceptably low TLR and MACE rates while having the benefit of a significantly shorter DAPT duration in a DES dominated clinical practice. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Fibrilación Atrial/etiología , Enfermedad de la Arteria Coronaria/terapia , Metales , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Stents , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Asia , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Fibrilación Atrial/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Quimioterapia Combinada , Europa (Continente) , Femenino , Hemorragia/inducido químicamente , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Diseño de Prótesis , Factores de Riesgo , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
3.
Arch Cardiovasc Dis ; 115(10): 505-513, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36123284

RESUMEN

BACKGROUND: Randomized trials comparing the first-generation absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, CA, USA) with a drug-eluting stent showed a moderate but significant increase in the rate of 3-year major adverse cardiac events and scaffold thrombosis, followed by a decrease in adverse events after 3 years. AIM: The objective of this study was to assess the 5-year outcomes of patients treated with at least one absorb BVS and included in the FRANCE ABSORB registry. METHODS: All patients treated in France with an absorb BVS were prospectively included in a large nationwide multicentre registry. The primary efficacy outcome was the occurrence of 5-year major adverse cardiac events. Secondary efficacy outcomes were the rates of 5-year target vessel revascularization and definite/probable scaffold thrombosis. RESULTS: Between September 2014 and April 2016, 2,070 patients were included in 86 centres (mean age 55±11 years; 80% men; 49% with acute coronary syndrome). The rates of 1-, 3- and 5-year major adverse cardiac events were 3.9%, 9.4% and 12.1%, respectively (including cardiac death in 2.5% and target vessel revascularization in 10.4%). By multivariable analysis, diabetes, oral anticoagulation, the use of multiple Absorb BVSs and the use of a 2.5mm diameter absorb BVS were associated with 5-year major adverse cardiac events. The rates of 1-, 3- and 5-year definite/probable scaffold thrombosis were 1.5%, 3.1% and 3.6%, respectively. By multivariable analysis, older age, diabetes, anticoagulation at discharge and the use of a 2.5mm diameter absorb BVS were associated with 5-year scaffold thrombosis. CONCLUSIONS: Absorb BVS implantation was associated with low rates of 1-year major adverse cardiac events, which increased significantly at 3-year follow-up. There was a clear decrease in the rates of scaffold thrombosis and major adverse cardiac events after 3 years.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Femenino , Implantes Absorbibles , Everolimus , Resultado del Tratamiento , Diseño de Prótesis , Factores de Tiempo , Sistema de Registros , Anticoagulantes , Intervención Coronaria Percutánea/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía
4.
Arch Cardiovasc Dis ; 105(2): 60-7, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22424323

RESUMEN

BACKGROUND: Coronary stents have evolved over time, from bare-metal stents to drug-eluting stents, and now to bioactive stents. AIMS: We sought to explore the immediate outcome of the titanium-nitride-oxide-coated bioactive stent, Titan2(®), in real-world practice, and the incidence of major cardiac events at follow-up. METHODS: Consecutive patients admitted for percutaneous intervention for at least one significant (≥50%) lesion in a native coronary artery were treated with Titan2(®) stent implantation. The primary endpoint was total major adverse cardiac events at 12-month follow-up. Secondary endpoints included target lesion revascularization at 12-month follow-up and the duration of dual antiplatelet therapy. RESULTS: Among 356 patients (mean age 67.4 ± 12.1 years), 77.2% were male and 39.3% were treated for myocardial infarction (MI). A total of 546 Titan2(®) stents were implanted in 420 lesions. Angiographic and clinical procedural success was achieved in all cases. No cases of in-hospital major adverse cardiac events or acute stent thrombosis were reported. Of 335 patients (94.1%) with 12-month clinical follow-up, four (1.2%) died, MI occurred in five (1.5%), target lesion revascularization was performed in 17 (5.1%) and major adverse cardiac events occurred in 24 (7.2%). One patient (0.3%) suffered late stent thrombosis during follow-up, but no cases of acute or subacute stent thrombosis occurred. Dual antiplatelet therapy continued beyond 6 months in 64.5% of patients. CONCLUSIONS: In real-world practice, Titan2(®) stent implantation achieves an excellent immediate outcome, with a low incidence of major adverse cardiac events at 12-month follow-up.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Materiales Biocompatibles Revestidos , Estenosis Coronaria/terapia , Infarto del Miocardio/terapia , Stents , Titanio , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Quimioterapia Combinada , Femenino , Francia , Agencias Gubernamentales , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Índice de Severidad de la Enfermedad , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA