Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circ J ; 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38960680

RESUMEN

BACKGROUND: This study compared the stability of the Medtronic Attain Stability Quad (ASQ), a novel quadripolar active fixation left ventricular (LV) lead with a side helix, to that of conventional quadripolar leads with passive fixation (non-ASQ) and evaluated their LV lead performance.Methods and Results: In all, 183 consecutive patients (69 ASQ, 114 non-ASQ) who underwent cardiac resynchronization therapy (CRT) between January 2018 and June 2021 were enrolled. Complications, including elevated pacing capture threshold (PCT) levels, phrenic nerve stimulation (PNS), and LV lead dislodgement, were analyzed during the postimplantation period until the first outpatient visit after discharge. The frequency of LV lead-related complications was significantly lower in the ASQ than non-ASQ group (14% vs. 30%, respectively; P=0.019). Specifically, LV lead dislodgement occurred only in the non-ASQ group, and elevated PCT levels were significantly lower in the ASQ group (7% vs. 23%; P=0.007). Kaplan-Meier analysis confirmed a significantly lower incidence of LV lead-related complications in the ASQ group (log-rank P=0.005). Cox multivariable regression analysis showed a significant reduction in lead-related complications associated with ASQ (hazard ratio 0.44; 95% confidence interval 0.23-0.83; P=0.011). CONCLUSIONS: The ASQ group exhibited fewer LV lead-related complications requiring reintervention and setting changes than the non-ASQ group. Thus, the ASQ may be a favorable choice for CRT device implantation.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38214176

RESUMEN

To date, there have been no reports of recording epicardial electrograms at the onset of spontaneous ventricular fibrillation (VF) in patients with Brugada syndrome (BrS). In the case of BrS, unipolar and bipolar electrogram recording on the right ventricular epicardium revealed that dispersion of repolarization with delayed potential was associated with spontaneous occurrence of VF. Phase 2 reentry associated with shortening and dispersion of action potential could have been recorded for the first time in BrS. Epicardial unipolar mapping can guide accurate and appropriate ablation for the elimination of arrhythmia substrate in J wave syndrome.

3.
J Cardiovasc Electrophysiol ; 34(3): 556-564, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36718076

RESUMEN

INTRODUCTION: The superior vena cava (SVC) is the most common source of non-pulmonary vein foci in atrial fibrillation (AF); therefore, predicting the existence of non-pulmonary vein foci before the catheter ablation procedure helps construct a proper ablation strategy in preparation for SVC isolation. This study aimed to clarify the structural characteristics of patients with SVC foci initiating AF. METHODS: We enrolled 331 consecutive patients with AF who underwent cardiac computed tomography imaging before radiofrequency catheter ablation treatment, and they were divided into SVC (+) and (-) groups based on the presence or absence of SVC foci initiating AF. RESULTS: The SVC (+) group (n = 27) exhibited SVC crescent signs-defined as a curve-shaped SVC with two narrow pointed ends-more frequently (37% vs. 9%, p < .001), and larger right atrial volume (95.6 ± 20.8 vs. 80.5 ± 26.1 mL, p = .004) than the SVC (-) group (n = 304). Multivariate logistic regression analysis revealed that the SVC crescent sign (odds ratio, 8.88; 95% confidence interval [CI], 3.21-24.60) and right atrial volume (odds ratio, 1.03; 95% CI, 1.01-1.04) were independent predictors of SVC foci. CONCLUSION: Patients with SVC foci exhibited more frequent SVC crescent signs and larger right atrial volumes, and these characteristics may help clinicians choose the appropriate ablation technology.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Vena Cava Superior , Electrocardiografía , Atrios Cardíacos , Tomografía Computarizada por Rayos X , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento
4.
Circ J ; 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38057103

RESUMEN

BACKGROUND: Atrial tachyarrhythmias (ATAs) are reportedly associated with ventricular arrhythmias (VAs). However, little is known about the association between ATA duration and the risk of VA. We investigated the relationship between ATA duration and subsequent VA in patients with a cardiac resynchronization therapy defibrillator (CRT-D).Methods and Results: We investigated associations between the longest ATA duration during the first year after cardiac resynchronization therapy (CRT) implantation and VA and VA relevant to ATA (VAATA) in 160 CRT-D patients. ATAs occurred in 63 patients in the first year. During a median follow-up of 925 days from 1 year after CRT implantation, 40 patients experienced 483 VAs. Kaplan-Meier analysis showed a significantly higher risk of VA in patients with than without ATA in the first year (log rank P=0.0057). Hazard ratios (HR) of VA (HR 2.36, 2.10, and 3.04 for ATA >30s, >6 min and >24 h, respectively) and only VAATA (HR 4.50, 5.59, and 11.79 for ATA >30s, >6 min and >24 h, respectively) increased according to the duration of ATA. In multivariate analysis, ATA >24 h was an independent predictor of subsequent VA (HR 2.42; P=0.02). CONCLUSIONS: Patients with ATA >24 h in the first year after CRT had a higher risk of subsequent VA and VAATA. The risk of VA, including VAATA, increased with the longest ATA duration.

5.
Pacing Clin Electrophysiol ; 46(8): 833-839, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37485704

RESUMEN

INTRODUCTION: Infection is one of the most important complications associated with cardiac implantable electronic device (CIED) therapy. The number of reports comparing the outcomes of transvenous lead extraction (TLE), surgical lead extraction, and conservative treatment for CIED infections using a real-world database is limited. This study investigated the association between the treatment strategies for CIED infections and their outcomes. METHODS: We performed a retrospective analysis of 3605 patients with CIED infections admitted to 681 hospitals using a nationwide claim-based database collected between April 2012 and March 2018. RESULTS: We divided the 3605 patients into TLE (n = 938 [26%]), surgical lead extraction (n = 182 [5.0%]), and conservative treatment (n = 2485 [69%]) groups. TLE was performed more frequently in younger patients and at larger hospitals (p for trend < .001 for both). The rate of TLE increased during the study period, whereas that of surgical lead extraction decreased (p for trend < .001 for both). TLE was associated with lower in-hospital mortality (vs. surgical lead extraction: odds ratio [OR], 0.20; 95% CI, 0.06-0.70; vs. conservative treatment: OR, 0.45; 95% CI: 0.22-0.94) and lower 30-day readmission rates (vs. surgical lead extraction: OR, 0.18; 95% CI: 0.06-0.56; vs. conservative treatment: OR, 0.06; 95% CI, 0.03-0.13) in propensity score-weighted analyses. CONCLUSIONS: Only 26% of patients hospitalized for CIED infections received TLE. TLE was associated with significantly lower in-hospital mortality and 30-day recurrence rates than surgical lead extraction and conservative treatment, suggesting that TLE should be more widely recommended as a first-line treatment for CIED infections.


Asunto(s)
Desfibriladores Implantables , Cardiopatías , Marcapaso Artificial , Humanos , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Tratamiento Conservador , Estudios Retrospectivos , Puntaje de Propensión , Remoción de Dispositivos , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 33(3): 423-429, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34921701

RESUMEN

INTRODUCTION: Utilizing a three-dimensional (3-D) mapping system and intracardiac echocardiography (ICE) has allowed ablation procedures with less or without fluoroscopy; however, there is limited data for patients with cardiac electronic implantable device (CIED) leads regarding the suspected risk of lead injury. Therefore, we sought to explore technics to perform safe trans-septal approach and catheter manipulation technique in patients with CIED leads. METHODS AND RESULTS: This study comprised 49 consecutive patients (59% males, median 73 years old) with CIED who underwent catheter ablation for supraventricular tachycardia requiring the trans-septal approach, 15 without fluoroscopy (zero-fluoro group), and 34 with fluoroscopy (conventional-fluoro group), between July 2019 and April 2021. All procedures were performed under a 3-D mapping system and ICE guidance. We compared the differences in treatment and development of complications between the two groups. The procedures were for atrial fibrillation (82%) and atrial tachycardia (76%). Coronary sinus catheter insertion and the trans-septal procedure were successfully performed in all patients. The median time from venipuncture to trans-septal procedure (zero-fluoro vs. conventional-fluoro group: 28 [18-37] min vs. 24 [21-31] min, p = .70), total procedure time (231 [142-274] min vs. 175 [163-225] min, p = .63), and the acute procedural success rate (100% vs. 97%, p = 1.00) did not differ between both groups. No patient showed lead-related complications in both groups. CONCLUSION: This is the first study to show zero-fluoro ablation for supraventricular arrhythmia using 3-D mapping and ICE in patients with CIED leads was feasible under careful catheter manipulation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Anciano , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Electrónica , Femenino , Fluoroscopía/métodos , Humanos , Masculino , Taquicardia Supraventricular/diagnóstico por imagen , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
7.
Heart Vessels ; 37(5): 794-801, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34677657

RESUMEN

Factors causing atrial tachyarrhythmia recurrence after catheter ablation (CA) of atrial fibrillation (AF) remain undetermined. This study aimed to investigate the effect of nocturnal hypoxemia on the recurrence of atrial tachyarrhythmia after CA of AF. Among 594 patients with AF who underwent an ambulatory sleep study at the National Cerebral and Cardiovascular Center, Suita, Osaka, Japan (2014-2019), 365 underwent CA of AF; 290 patients who underwent CA were followed up for > 3 months. Multivariate Cox regression analysis was used to calculate hazard ratios (HRs) using clinical variables, to identify the independent predictors of atrial tachyarrhythmia recurrence after the final CA. Atrial tachyarrhythmia recurred in 45 of 290 (15.5%) patients during the median follow-up period of 479 days (interquartile range 225-1002). On the performing multivariate analysis of the data of patients who did not receive continuous positive airway pressure (CPAP), severe nocturnal hypoxemia [defined as the percentage of sleep time spent with SaO2 of < 90% (T90) over 20%] [HR 8.53, 95% confidence interval (CI) 1.872-38.814; P < 0.01] and an 1 mL/m2 increase in the left atrial volume index (HR 1.02, 95% CI 1.004-1.044; P = 0.02) were found to be independently associated with the recurrence of atrial tachyarrhythmia. In addition, the rates of freedom from atrial tachyarrhythmia after the final AF ablation with CPAP were significantly lower in the group with more severe nocturnal hypoxemia (Log-rank P = 0.03). In conclusion, it is necessary to consider both, AHI and nocturnal hypoxia while performing an ambulatory sleep apnea study. CA may be less effective in patients with more severe nocturnal hypoxia, despite the administration of CPAP.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Humanos , Hipoxia/complicaciones , Recurrencia , Factores de Riesgo , Taquicardia/complicaciones , Taquicardia/cirugía , Resultado del Tratamiento
8.
Eur Heart J ; 42(29): 2854-2863, 2021 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-34219138

RESUMEN

AIMS: The prognostic value of genetic variants for predicting lethal arrhythmic events (LAEs) in Brugada syndrome (BrS) remains controversial. We investigated whether the functional curation of SCN5A variations improves prognostic predictability. METHODS AND RESULTS: Using a heterologous expression system and whole-cell patch clamping, we functionally characterized 22 variants of unknown significance (VUSs) among 55 SCN5A mutations previously curated using in silico prediction algorithms in the Japanese BrS registry (n = 415). According to the loss-of-function (LOF) properties, SCN5A mutation carriers (n = 60) were divided into two groups: LOF-SCN5A mutations and non-LOF SCN5A variations. Functionally proven LOF-SCN5A mutation carriers (n = 45) showed significantly severer electrocardiographic conduction abnormalities and worse prognosis associated with earlier manifestations of LAEs (7.9%/year) than in silico algorithm-predicted SCN5A carriers (5.1%/year) or all BrS probands (2.5%/year). Notably, non-LOF SCN5A variation carriers (n = 15) exhibited no LAEs during the follow-up period. Multivariate analysis demonstrated that only LOF-SCN5A mutations and a history of aborted cardiac arrest were significant predictors of LAEs. Gene-based association studies using whole-exome sequencing data on another independent SCN5A mutation-negative BrS cohort (n = 288) showed no significant enrichment of rare variants in 16 985 genes including 22 non-SCN5A BrS-associated genes as compared with controls (n = 372). Furthermore, rare variations of non-SCN5A BrS-associated genes did not affect LAE-free survival curves. CONCLUSION: In vitro functional validation is key to classifying the pathogenicity of SCN5A VUSs and for risk stratification of genetic predictors of LAEs. Functionally proven LOF-SCN5A mutations are genetic burdens of sudden death in BrS, but evidence for other BrS-associated genes is elusive.


Asunto(s)
Síndrome de Brugada , Síndrome de Brugada/genética , Humanos , Mutación/genética , Canal de Sodio Activado por Voltaje NAV1.5/genética , Fenotipo , Virulencia
9.
Int Heart J ; 63(5): 828-836, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36184544

RESUMEN

The efficacy of direct current (DC) cardioversion before catheter ablation (CA) for persistent atrial fibrillation (PerAF) patients remains controversial. We hypothesized that maintenance of sinus rhythm (SR) by pre-ablation DC cardioversion may predict the outcome of CA in patients with PerAF. A total of 383 PerAF patients with no or mild symptoms (EHRA I/II) who had undergone DC cardioversion before CA (301 males, 65 ± 10 years old, mean atrial fibrillation (AF) duration: 25 ± 47 months) were retrospectively enrolled. Whether or not SR was maintained at least 24 hour after DC cardioversion, patients were divided into two groups, namely, the DC-SR group and DC-AF group, and then all were followed until AF recurrence after CA. After DC cardioversion, 281 (73%) patients were categorized into the DC-SR group, and 102 (27%) were categorized into the DC-AF group. A total of 195 patients underwent CA at an average of 83 (54-145) days after DC cardioversion, including 161 (83%) in the DC-SR group and 34 (17%) in the DC-AF group. During follow-up (median: 15 [10-25] months), the number of patients who were free from AF was significantly higher in the DC-SR group compared with the DC-AF group (61.5% versus 38.3%, P < 0.0001). Multivariate analysis revealed that the DC-SR group (hazard ratio [HR]: 0.45, 95% confidence interval [CI]: 0.21-0.99, P = 0.047) and age at first AF diagnosis (HR: 0.95, 95% CI: 0.91-1.00, P = 0.039) were the independent predictors for being AF-free after CA. In conclusion, the 24-hour rhythm outcome of pre-ablation DC cardioversion and age at first AF diagnosis may predict the recurrence of AF after CA in patients with PerAF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Ablación por Catéter/efectos adversos , Cardioversión Eléctrica/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
10.
J Cardiovasc Electrophysiol ; 32(5): 1320-1327, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33600020

RESUMEN

INTRODUCTION: The sinoatrial node (SAN) should be identified before superior vena cava (SVC) isolation to avoid SAN injury. However, its location cannot be identified without restoring sinus rhythm. This study evaluated the usefulness of the anatomically defined SAN by comparing it with the electrically confirmed SAN (e-SAN) to predict the top-most position of e-SAN and thus establish a safe and more efficient anatomical reference for SVC isolation than the previously reported reference of the right superior pulmonary vein (RSPV) roof. METHODS AND RESULTS: The e-SAN was identified as the earliest activation site in the electroanatomical map obtained during sinus rhythm. The anatomically defined SAN, the cranial edge of the crista terminalis (CT) visualized with intracardiac echocardiography (CT top), and the RSPV roof, which was obtained from the overlaid electroanatomical image of SVC and RSPV, were tagged on one map. The distance from the e-SAN to each reference was measured. Among 77 patients, the height of the e-SAN from the CT top was a median (interquartile range) of -2.0 (-8.0 to 4.0) mm. The e-SAN existed from 10 mm above the CT top or lower in 74 (96%) patients and from the RSPV roof or below in 73 (95%) patients. The reference of 10 mm above the CT top is more proximal to the right atrium than the RSPV roof and can provide longer isolatable SVC sleeves (30.0 [20.0-35.0] vs. 24.0 [18.0-30.0] mm, p < .001). The e-SAN tended to be found above the CT top when the heart rate during mapping was faster (adjusted odds ratio [95% confidence interval] per 10-bpm increase: 1.71 [1.20-2.43], p < .01). CONCLUSION: The CT top is useful for predicting the upper limit of the e-SAN and can provide a better reference for SVC isolation than the RSPV roof.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Nodo Sinoatrial , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía
11.
J Cardiovasc Electrophysiol ; 32(3): 772-781, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33428312

RESUMEN

BACKGROUND: Determining the etiology of syncope is challenging in Brugada syndrome (BrS) patients. Implantable cardioverter defibrillator placement is recommended in BrS patients who are presumed to have arrhythmic syncope. However, arrhythmic syncope in BrS patients can occur in the setting of atrioventricular block (AVB), which should be managed by cardiac pacing. The clinical characteristics of BrS patients with high-risk AVB remain unknown. METHODS: This study included 223 BrS patients with a history of syncope from two centers. The clinical characteristics of patients with high-risk AVB (Mobitz type II second-degree AVB, high-degree AVB, or third-degree AVB) were investigated. RESULTS: During the 99 ± 78 months of follow-up, we identified six BrS patients (2.7%) with high-risk AVB. Three of the six patients (50%) with AVB presented with syncope associated with prodromes or specific triggers. Four patients (67%) were found to have paroxysmal third-degree AVB during the initial evaluation for BrS and syncope, while two patients developed third-degree AVB during the follow-up period. The incidence of first-degree AVB was significantly higher in AVB patients than in non-AVB patients (83% vs. 15%; p = .0005). There was no significant difference in the incidence of ventricular fibrillation between AVB and non-AVB patients (AVB [17%], non-AVB [12%]; p = .56). CONCLUSION: High-risk AVB can occur in BrS patients with various clinical presentations. Although rare, the incidence is worth considering, especially in BrS patients with first-degree AVB.


Asunto(s)
Bloqueo Atrioventricular , Síndrome de Brugada , Desfibriladores Implantables , Bloqueo Atrioventricular/diagnóstico , Síndrome de Brugada/complicaciones , Síndrome de Brugada/diagnóstico , Electrocardiografía , Humanos , Síncope/diagnóstico , Síncope/epidemiología
12.
Heart Vessels ; 36(5): 675-685, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33580804

RESUMEN

Atrial tachycardia (AT) and atrial fibrillation (AF) commonly occur after cardiac surgeries (CSs). This study investigated the mechanisms and long-term outcomes of AT and AF ablation after various Maze procedures, particularly whether atrial tachyarrhythmias after the Maze procedure occur due to gaps in the Maze lines. We analyzed 37 consecutive cases with atrial tachyarrhythmias after the Maze procedures and concomitant CSs between 2007 and 2019. Fifty-nine atrial tachyarrhythmias were induced in 37 consecutive cases, and 49 of those atrial tachyarrhythmias were mappable ATs. Forty ATs were related to the Maze procedures in the 49 mappable ATs (81.6%). All 37 consecutive cases had residual electrical conductions (gaps) in the Maze lines (88 gaps; 2.4 ± 1.2 gaps/patient). Forty of 88 gaps (45.5%) were associated with gap-related ATs. The common ATs in this study were 1. peri-mitral atrial flutter due to gaps at pulmonary vein isolation (PVI) line to mitral valve annulus (MVA) (20 cases), and 2. peri-tricuspid atrial flutter due to gaps at right atrial incision to the tricuspid valve annulus (TVA) (10 cases). Forty-seven of 49 ATs (95.9%) were successfully ablated at the first session, and there were no complications. The mean follow-up period after ablation was 3.6 ± 3.2 (median, 2.1; interquartile range, 0.89-6.84) years. The Kaplan-Meier analysis of freedom from recurrent atrial tachyarrhythmias after Maze procedure was 82.7% at 1-year follow-up and 75.5% at 4-year follow-up after a single procedure. Reentry was the main mechanism of ATs after Maze procedures and concomitant CSs, and ATs were largely related to the gaps on the Maze lines between the PVI line and the MVA or those on the lines between right atrial incision to the TVA. Long-term follow-up data suggest that catheter ablation of atrial tachyarrhythmias after various Maze procedures is effective and safe.


Asunto(s)
Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ablación por Catéter/efectos adversos , Atrios Cardíacos/fisiopatología , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
13.
Int Heart J ; 62(4): 927-931, 2021 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-34276015

RESUMEN

A 70-year-old female with dextrocardia with situs inversus (DSI) totalis and inferior vena cava occlusion underwent radiofrequency catheter ablation because she had symptomatic paroxysmal atrial fibrillation (AF). Careful preoperative examination made successful pulmonary vein isolation through the left jugular vein approach. One-year later, however, AF recurred, and symptomatic sinus bradycardia or junctional bradycardia often occurred. Then, the pacemaker was implanted. We here reported a rare case of congenital abnormality, DSI with inferior vena cava occlusion who had undergone successful pulmonary vein isolation and pacemaker implantation without any complications.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Dextrocardia/diagnóstico por imagen , Marcapaso Artificial , Síndrome del Seno Enfermo/cirugía , Anciano , Fibrilación Atrial/complicaciones , Femenino , Humanos , Situs Inversus
14.
Europace ; 22(6): 972-979, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32167564

RESUMEN

AIMS: To establish the indication for programmed ventricular stimulation (PVS) for asymptomatic patients with Brugada syndrome (BrS), we evaluated the prognostic significance of PVS based on abnormal electrocardiogram (ECG) markers. METHODS AND RESULTS: One hundred and twenty-five asymptomatic patients with BrS were included. We performed PVS at two sites of the right ventricle with up to three extrastimuli [two pacing cycle lengths and minimum coupling interval (MCI) of 180 ms]. We followed the patients for 133 months and evaluated ventricular fibrillation (VF) events. Fragmented QRS (fQRS) and Tpeak-Tend (Tpe) interval were evaluated as ECG markers for identifying high-risk patients. Fragmented QRS and long Tpe interval (≥100 ms) were observed in 66 and 37 patients, respectively. Ventricular fibrillation was induced by PVS in 60 patients. During follow-up, 10 patients experienced VF events. Fragmented QRS, long Tpe interval, and PVS-induced VF with an MCI of 180 ms or up to two extrastimuli were associated with future VF events (fQRS: P = 0.015, Tpe ≥ 100 ms: P = 0.038, VF induction: P < 0.001). However, PVS-induced VF with an MCI of 200 ms was less specific (P = 0.049). The frequencies of ventricular tachyarrhythmia events during follow-up were 0%/year with no ECG markers and 0.1%/year with no VF induction. The existence of two ECG factors with induced VF was strongly associated with future VF events (event rate: 4.4%/year, P < 0.001), and the existence of one ECG factor with induced VF was also associated (event rate: 1.3%/year, P = 0.011). CONCLUSION: We propose PVS with a strict protocol for asymptomatic patients with fQRS and/or long Tpe interval to identify high-risk patients.


Asunto(s)
Síndrome de Brugada , Síndrome de Brugada/diagnóstico , Electrocardiografía , Ventrículos Cardíacos , Humanos , Pronóstico , Fibrilación Ventricular/diagnóstico
15.
Circ J ; 84(12): 2158-2165, 2020 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-33071242

RESUMEN

BACKGROUND: The new guideline (NG) published by the Japanese Circulation Society (JCS) places emphasis on previous arrhythmic syncope and inducibility of ventricular fibrillation (VF) by ≤2 extrastimuli during programmed electrical stimulation (PES) for deciding the indication of an implantable cardioverter-defibrillator in patients with Brugada syndrome (BrS). This study evaluated the usefulness of the NG and compared it with the former guideline (FG) for risk stratification of patients with BrS.Methods and Results:This was a multicenter (7 Japanese hospitals) retrospective study involving 234 patients with BrS who underwent PES at baseline (226 males; mean age at diagnosis: 44.9±13.4 years). At diagnosis, 46 patients (20%) had previous VF, 100 patients (43%) had previous syncope, and 88 patients (37%) were asymptomatic. We evaluated the difference in the incidence of VF in each indication according to the new and FGs. During the follow-up period (mean: 6.9±5.2 years), the incidence of VF was higher in patients with Class IIa indication according to the NG (NG: 16/45 patients [35.6%] vs. FG: 16/104 patients [15.4%]), while the incidence of VF in patients with other than class I or IIa indication was similarly low in both guidelines (NG: 2/143 patients [1.4%] vs. FG: 2/84 patients [2.4%]). CONCLUSIONS: This study validated the usefulness of the NG for risk stratification of BrS patients.


Asunto(s)
Síndrome de Brugada , Desfibriladores Implantables , Fibrilación Ventricular , Adulto , Síndrome de Brugada/terapia , Electrocardiografía , Femenino , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Estudios Retrospectivos , Medición de Riesgo , Síncope , Fibrilación Ventricular/terapia
16.
Circ J ; 84(12): 2166-2174, 2020 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-33162489

RESUMEN

BACKGROUND: Approximately one-third of patients with advanced heart failure (HF) do not respond to cardiac resynchronization therapy (CRT). We investigated whether the left ventricular (LV) conduction pattern on magnetocardiography (MCG) can predict CRT responders.Methods and Results:This retrospective study enrolled 56 patients with advanced HF (mean [±SD] LV ejection fraction [LVEF] 23±8%; QRS duration 145±19 ms) and MCG recorded before CRT. MCG-QRS current arrow maps were classified as multidirectional (MDC; n=28) or unidirectional (UDC; n=28) conduction based on a change of either ≥35° or <35°, respectively, in the direction of the maximal current arrow after the QRS peak. Baseline New York Heart Association functional class and LVEF were comparable between the 2 groups, but QRS duration was longer and the presence of complete left bundle branch block and LV dyssynchrony was higher in the UDC than MDC group. Six months after CRT, 30 patients were defined as responders, with significantly more in the UDC than MDC group (89% vs. 14%, respectively; P<0.001). Over a 5-year follow-up, Kaplan-Meyer analysis showed that adverse cardiac events (death or implantation of an LV assist device) were less frequently observed in the UDC than MDC group (6/28 vs. 15/28, respectively; P=0.027). Multivariate analysis revealed that UDC on MCG was the most significant predictor of CRT response (odds ratio 69.8; 95% confidence interval 13.14-669.32; P<0.001). CONCLUSIONS: Preoperative non-invasive MCG may predict the CRT response and long-term outcome after CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Magnetocardiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Humanos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento
17.
BMC Endocr Disord ; 20(1): 177, 2020 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-33256676

RESUMEN

BACKGROUND: Plasma aldosterone-to-renin ratio (ARR) is popularly used for screening primary aldosteronism (PA). Some medications, including diuretics, are known to have an effect on ARR and cause false-negative and false-positive results in PA screening. Currently, there are no studies on the effects of sodium-glucose cotransporter-2 (SGLT2) inhibitors, which are known to have diuretic effects, on ARR. We aimed to investigate the effects of SGLT2 inhibitors on ARR. METHODS: We employed a retrospective design; the study was conducted from April 2016 to December 2018 and carried out in three hospitals. Forty patients with diabetes and hypertension were administered SGLT2 inhibitors. ARR was evaluated before 2 to 6 months after the administration of SGLT2 inhibitors to determine their effects on ARR. RESULTS: No significant changes in the levels of ARR (90.9 ± 51.6 vs. 81.4 ± 62.9) were found. Body mass index, diastolic blood pressure, heart rate, fasting plasma glucose, and hemoglobin A1c were significantly decreased by SGLT2 inhibitors. Serum creatinine was significantly increased. CONCLUSION: SGLT2 inhibitor administration yielded minimal effects on ARR and did not increase false-negative results in PA screening in patients with diabetes and hypertension more than 2 months after administration.


Asunto(s)
Aldosterona/sangre , Diabetes Mellitus Tipo 2/sangre , Hipertensión/sangre , Renina/sangre , Inhibidores del Cotransportador de Sodio-Glucosa 2/uso terapéutico , Anciano , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Femenino , Humanos , Hiperaldosteronismo/sangre , Hiperaldosteronismo/tratamiento farmacológico , Hiperaldosteronismo/epidemiología , Hipertensión/tratamiento farmacológico , Hipertensión/epidemiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Inhibidores del Cotransportador de Sodio-Glucosa 2/farmacología , Resultado del Tratamiento
18.
Ann Noninvasive Electrocardiol ; 25(4): e12741, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31955494

RESUMEN

BACKGROUND: The early repolarization pattern (ERP) in electrocardiography (ECG) has been considered as a risk for ventricular fibrillation (VF), but effective methods for identification of malignant ERP are still required. We investigated whether high spatiotemporal resolution 64-channel magnetocardiography (MCG) would enable distinction between benign and malignant ERPs. METHODS: Among all 2,636 subjects who received MCG in our facility, we identified 116 subjects (43 ± 18 years old, 54% male) with inferior and/or lateral ERP in ECG and without structural heart disease, including 13 survivors of VF (ERP-VF(+)) and 103 with no history of VF (ERP-VF(-)). We measured the following MCG parameters in a time-domain waveform of relative current magnitude: (a) QRS duration (MCG-QRSD), (b) root-mean-square of the last 40 ms (MCG-RMS40), and (c) low amplitude (<10% of maximal) signal duration (MCG-LAS). RESULTS: Compared to ERP-VF(-), ERP-VF(+) subjects presented a significantly longer MCG-QRS (108 ± 24 vs. 91 ± 23 ms, p = .02) and lower MCG-RMS40 (0.10 ± 0.08 vs. 0.25 ± 0.20, p = .01) but no difference in MCG-LAS (38 ± 22 vs. 29 ± 23 ms, p = .17). MCG-QRSD and MCG-RMS40 showed significantly larger area under the ROC curve compared to J-peak amplitude in ECG (0.72 and 0.71 vs. 0.50; p = .04 and 0.03). The sensitivity, specificity, and odds ratio for identifying VF(+) based on MCG-QRSD ≥ 100 ms and MCG-RMS40 ≤ 0.24 were 69%, 74%, and 6.33 (95% CI, 1.80-22.3), and 92%, 48%, and 10.9 (95% CI, 1.37-86.8), respectively. CONCLUSION: Magnetocardiography is an effective tool to distinguish malignant and benign ERPs.


Asunto(s)
Magnetocardiografía/métodos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología , Adulto , Femenino , Humanos , Masculino
19.
J Cardiovasc Electrophysiol ; 30(9): 1578-1585, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31231904

RESUMEN

INTRODUCTION: Fast junctional rhythm (JR) during slow pathway modification for atrioventricular nodal reentrant tachycardia (AVNRT) is a predictor of serious atrioventricular block. This study investigated the boundary to avoid fast JR during ablation with three-dimensional (3D) electroanatomical mapping in AVNRT patients. METHODS AND RESULTS: Participants were 129 consecutive patients with common AVNRT who received anatomical ablation to an antegrade slow pathway at our institution between August 2013 and March 2019. Successfully ablated sites with JR were evaluated in terms of distances and angles in the left and right anterior oblique views (LAO and RAO, respectively) to the proximal His bundle (His) site using 3D mapping. We divided JR by heart rate: JR1 ≥150 bpm and JR2 <150 bpm. Average age was 61 ± 16 years; 41.1% of patients were male. The distance from the most proximal His to the JR1 and JR2 site was not significantly different (11.9 ± 4.4 vs 10.7 ± 4.5 mm, P = .24). JR1 predominantly appeared closer to the left ventricle than JR2 in LAO (110.5 ± 19.1° vs 77.5 ± 18.6°, P < .01), and was more posterior from the proximal His in RAO (30.8% vs 6.8%, P < .01). The vertical line drawn down from the proximal His in the LAO view was a good indicator of JR1 appearance (sensitivity and specificity 84.6% and 81.6%, respectively). CONCLUSION: The vertical line drawn down from the proximal His in the LAO view can be employed as a boundary to avoid fast JR during ablation in AVNRT.


Asunto(s)
Nodo Atrioventricular/cirugía , Ablación por Catéter , Frecuencia Cardíaca , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Potenciales de Acción , Anciano , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/fisiopatología , Nodo Atrioventricular/fisiopatología , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
20.
Europace ; 21(11): 1663-1669, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31410454

RESUMEN

AIMS: There is no valid treatment strategy for addressing paroxysmal atrial fibrillation (AF) in patients with unclosed atrial septal defect (ASD). We aimed to assess the efficacy of catheter ablation (CA) compared with transcatheter ASD closure alone for treating pre-existing paroxysmal AF in patients with ASD. METHODS AND RESULTS: Among 908 patients who underwent transcatheter ASD closure, we evaluated 50 consecutive patients (63 ± 12 years) with paroxysmal AF. We compared the AF outcomes of these patients after transcatheter ASD closure between those with and without CA prior to ASD closure. Thirty (60%) patients underwent CA. During the follow-up period after ASD closure (mean: 49 ± 23 months), recurrence of AF was observed in 6/30 (20%) patients with upfront CA and 12/20 (60%) patients with ASD closure alone. Kaplan-Meier analysis showed that the AF-free survival rate was significantly higher for patients with CA than for those with ASD closure alone (79% vs. 37% at 5 years, P = 0.002). Upfront CA and previous heart failure hospitalization were associated with recurrence of AF after ASD closure [hazard ratio (HR) 0.18, 95% confidence interval (CI) 0.06-0.53; P = 0.002 and HR 4.64, 95% CI 1.60-13.49; P = 0.005, respectively]. CONCLUSION: In ASD patient with paroxysmal AF, transcatheter ASD closure alone demonstrated high AF recurrence rate after ASD closure. On the other hand, upfront CA prior to ASD closure substantially suppressed AF recurrence over the long term. A combination of CA and transcatheter ASD closure may be a feasible treatment strategy for paroxysmal AF in patients with ASD.


Asunto(s)
Fibrilación Atrial/cirugía , Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Ablación por Catéter/métodos , Defectos del Tabique Interatrial/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Defectos del Tabique Interatrial/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA