1.
J Prosthet Dent ; 125(2): 294-299, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32115221

RESUMEN

STATEMENT OF PROBLEM: Intraoral scanners (IOSs) have some inherent distortions caused by optical and/or software imperfections. However, how other factors such as operator experience, scan time, scanner type, and scan size influence scan accuracy is not clear. PURPOSE: The purpose of this in vitro study was to evaluate the trueness and precision of scans performed by 3 professionals with different levels of experience by using 2 IOSs. MATERIAL AND METHODS: Three operators with low, medium, and high levels of experience scanned a master model 10 times by using 2 IOSs (CEREC Omnicam; Dentsply Sirona and TRIOS 3; 3Shape), resulting in 10 standard tessellation language files for each group (N=60). Each standard tessellation language file was divided into 2 areas (prepared teeth and complete arch). Precision was evaluated by comparing the 10 scans from each examiner for each system. Trueness was evaluated by comparing each scan file with a reference scan obtained from a laboratory scanner (D2000; 3Shape). A 3D analysis software program (Geomagic Control; 3D Systems) was used to perform all the comparisons and superimpositions. The 3-way ANOVA test followed by the Tukey HSD test were used to assess precision and trueness. The 2-way ANOVA followed by the Tukey HSD test was used to assess scan time. The Pearson correlation test was performed between scan time and trueness for both scanners. An additional correlation was performed between scan time and number of images, as well as between number of images and trueness for the TRIOS 3. RESULTS: Statistically significant influences of operator (P<.001), scanner (P<.001), scan size (P<.001), operator and scan size (P<.001), and scanner and scan size (P<.001) were observed. The TRIOS 3 group reported higher precision than the CEREC Omnicam group for complete-arch scans (P<.001), although no difference was observed for scans of the prepared tooth. Medium- (P=.002) and low-experience operators (P<.001) reported lower precision for complete-arch scans performed with CEREC Omnicam when compared with TRIOS 3. The low-experience operator reported significantly worse results for complete-arch scans in comparison with the medium- (P=.008 and P<.001) and high-experience operators (P<.001 and P=.001), by using TRIOS 3 and CEREC Omnicam, respectively. Medium- and high-experience operators reported similar results among themselves. The CEREC Omnicam scanner reported lower trueness for complete-arch scans when compared with the prepared tooth (P<.001); for TRIOS 3, a difference was only observed for the low-experience operator when compared with the high-experience operator (P<.001). The CEREC Omnicam reported lower trueness than the TRIOS 3, except for the medium-experience operator with the prepared tooth scan. Comparing the trueness between operators and considering the same scanner and scan size, all groups were similar. The low-experience operator had a longer scanning time than the medium- and high-experience operators. For TRIOS 3, the low-experience operator obtained the highest number of images during each scan. CONCLUSIONS: The accuracy of intraoral scans was influenced by operator experience, type of IOSs, and scan size. More experienced operators and smaller scan sizes made for more accurate scans. In addition, more experienced operators made faster scans, and the TRIOS 3 was more accurate than the CEREC Omnicam for complete-arch scans.


Asunto(s)
Técnica de Impresión Dental , Modelos Dentales , Diseño Asistido por Computadora , Arco Dental , Imagenología Tridimensional
2.
Gen Dent ; 69(5): 62-66, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34424215

RESUMEN

The aim of this study was to evaluate the influence of the geometry of the screwdriver-screw connection on the reverse torque of UCLA screws after repeated cycles of tightening and loosening in an implant-supported prosthesis. Thirty sets of external hex titanium implants, UCLA abutments, and UCLA abutment screws were divided into 3 experimental groups (n = 10). In the square group, the implant and UCLA abutment system were mounted in an upright position using a screw with a square screwdriver-screw connection. In the hexagonal group, the implant and UCLA abutment system were mounted in an upright position using a screw with a hexagonal screwdriver-screw connection. In the hexalobular group, the implant and UCLA abutment system were mounted at 70° using a dynamic UCLA abutment and screw with a hexalobular screwdriver-screw connection. Ten alternating torque-reverse torque cycles were applied to each screw using a screwdriver fixed at the end of a digital torque meter. The screws with a square connection resulted in less loss of reverse torque than the other types. Screws with a hexagonal connection showed a statistically significant loss of torque initially but remained constant for the remaining cycles. For the screws with a hexalobular connection, the loss of torque was greater, and substantial deformation of the plastic in the microstructure was noted. The screwdriver-screw connection geometry had a direct influence on the reverse torque of UCLA screws, and the initial reverse torque of the abutment screws with a square connection was greater than that of the hexagonal and hexalobular designs.


Asunto(s)
Pilares Dentales , Implantes Dentales , Tornillos Óseos , Análisis del Estrés Dental , Humanos , Torque
3.
J Prosthet Dent ; 122(1): 54.e1-54.e6, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31202549

RESUMEN

STATEMENT OF PROBLEM: Narrow implants have limited indications, and implant fracture may occur when these indications are not followed. PURPOSE: The purpose of this in vitro study was to investigate the mechanical behavior of a 2.9-mm-diameter implant using a fatigue limit test and to investigate the Morse effect of 2 different Morse taper systems, 2.9-mm-diameter (FAC group) and 3.75-mm-diameter (CM group) implants, using a pull-out test. The null hypothesis was that the tensile strengths of the components for both systems would be similar. MATERIAL AND METHODS: The fatigue properties of 13 specimens under 6 loads were determined. The test was performed at 15 Hz and for 5×106 cycles. In the pull-out test, the specimens were divided into 2 groups (n=8), the FAC group (2.9-mm-diameter) and the CM group (3.75-mm-diameter). Statistical analysis for the pull-out test was performed with the Student t test (α=.05). RESULTS: Thirteen specimens underwent the fatigue test. Only 5 did not fail when subjected to the frequency and number of cycles examined. Three of the specimens did not fail under a load of 130 N. The pull-out test showed a significant difference between the FAC and CM groups (P<.001). CONCLUSIONS: According to the fatigue test, the extra-narrow implant (Facility; Neodent) was compatible with the low masticatory effort regions, as indicated by the manufacturer. The better performance of the FAC group in the pull-out test may be due to its design, which promotes the pure Morse effect in the implant-abutment interface, and the angulation of its internal conical portion.


Asunto(s)
Pilares Dentales , Implantes Dentales , Diseño de Implante Dental-Pilar , Análisis del Estrés Dental , Humanos , Ensayo de Materiales , Estrés Mecánico
4.
Implant Dent ; 26(3): 388-392, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28248689

RESUMEN

PURPOSE: This study evaluated the microleakage at different implant-abutment (I-A) connections under unloaded and loaded conditions. MATERIALS AND METHODS: Forty implants, specially designed with an opening at the apex, were grouped according to the I-A and screw device: external hexagon implants with titanium (EH) or EH diamond-like carbon screws fixing the abutment; internal hexagon implants with titanium screws (IH); and Morse taper implants with solid (MT) or MT passing screws (MTps) abutments. The implants were fixed in a 2-compartment device, and toluidine blue solution (1.0 mg/mL) was placed at the I-A interface (upper compartment). The lower compartment was filled with purified water. Four implants of each group were loaded (50 N, 1.2 Hz) and after 50,000, 100,000, 200,000, and 300,000 cycles, aliquots were collected from the lower compartment for absorbance reading. Data were analyzed using analysis of variance for repeated measurements and Tukey (α = 0.05). RESULTS: Although microleakage increased over time in most of the groups, MTps group showed lower values when loaded (P < 0.05). The DLC on the EH screw did not prevent microleakage (P < 0.05). CONCLUSION: It can be concluded that MT connection is more effective to prevent microleakage.


Asunto(s)
Diseño de Implante Dental-Pilar , Filtración Dental , Análisis del Estrés Dental , Diamante/química , Técnicas In Vitro , Ensayo de Materiales , Estrés Mecánico , Titanio/química
5.
Gen Dent ; 65(1): e14-e16, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28068275

RESUMEN

The aim of this study was to evaluate the influence of abutments with a prosthetic index on the fracture resistance of Morse taper dental implants. Morse taper implants were divided into 2 groups (n = 5 per group): a group with an indexed implant and a nonindexed abutment (solid Morse taper universal post; WIS group), and a group with an indexed implant and an indexed abutment (WIP group). Both groups were subjected to bending tests for fracture strength until 5 mm of displacement or implant fracture occurred. Statistical analysis was performed using the Student t test (α = 0.05). There was no statistically significant difference between the mean fracture values, which were 305.8 N and 318.6 N for the WIS group and WIP group, respectively. The presence of a prosthetic index on Morse taper abutments did not influence the resistance to fracture.


Asunto(s)
Pilares Dentales , Implantes Dentales , Fracaso de la Restauración Dental , Pilares Dentales/normas , Diseño de Implante Dental-Pilar/normas , Implantes Dentales/normas , Análisis del Estrés Dental , Humanos
6.
J Craniofac Surg ; 27(1): 238-41, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26674889

RESUMEN

This study aims to compare stress transmitted to implants and passive fit of one-piece cast frameworks fabricated with 3 different materials: commercially pure titanium (G1-CP Ti), cobalt-chromium alloy (G2-Co-Cr), and nickel-chromium-titanium alloy (G3-Ni-Cr-Ti). In total, 12 frameworks simulating bars for fixed prosthesis in a model with 5 implants were fabricated. The passive fit of the framework interface was measured using an optical microscope and the stresses transmitted to implants were measured using quantitative photoelastic analysis. Data were statistically analyzed by analysis of variance (ANOVA) and least significant difference (LSD) tests (α = 0.05). Mean and standard deviation values of passive fit and stress over implants are presented, respectively: G1 [472.49 (109.88) µm and 11.38 (9.23) KPa], G2 [584.84 (120.20) µm and 15.83 (9.30) KPa], and G3 [462.70 (179.18) µm and 16.39 (9.51) KPa]. For stress over implants, there were significant differences between G1, G2, and G3 (P = 0.035), being the lowest values for the G1. There were no significant differences for passive fit between G1 and G3 (P = 0.844), but both were statistically different from G2 (P = 0.028 and P = 0.035, respectively), which showed the worse results. It may be concluded that the stress over implants was affected by the tested materials. The CP Ti presented the best values for the evaluated items.


Asunto(s)
Aleaciones Dentales/química , Implantes Dentales , Materiales Dentales/química , Prótesis Dental de Soporte Implantado , Aleaciones/química , Aleaciones de Cromo/química , Revestimiento para Colado Dental/química , Técnica de Colado Dental , Adaptación Marginal Dental , Humanos , Ensayo de Materiales , Microscopía de Polarización , Distribución Aleatoria , Estrés Mecánico , Propiedades de Superficie , Titanio/química
7.
Implant Dent ; 25(4): 510-4, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27280738

RESUMEN

PURPOSE: The aim of this study was to compare the maximum load on the elastic limit of internal conical (IC) implants with regular external hexagon (REH) and narrow external hexagon (NEH) implants. MATERIALS AND METHODS: Thirty cylindrical implants were divided in 3 groups (n = 10): REH (3.75 mm); NEH (3.3 mm); IC (3.5 mm). The implants were evaluated by means of cantilever bending loads using a mechanical testing machine. A strain qualitative analysis and the corresponding angles were analyzed. Using single factor analysis of variance with Tukey Test and Friedman Test (P < 0.05) the statistical analysis for data were performed. RESULTS: REH (294.37 N) and IC (294.37 N) groups presented statistically greater Fle than NEH (189.16 N). Regarding to the strain, there were no significant differences among groups. However, there were a greater number of fissures and more fractures present on NEH group. CONCLUSION: The IC implant with smaller diameter did not result in reduction of elastic limit when compared with the REH implants. Nevertheless, the reduction of 0.45 mm of the hexagonal connection implant's diameter has significantly diminished the elastic limit.


Asunto(s)
Diseño de Implante Dental-Pilar/efectos adversos , Implantación Dental Endoósea/efectos adversos , Pilares Dentales/efectos adversos , Implantación Dental Endoósea/métodos , Fracaso de la Restauración Dental , Análisis del Estrés Dental/métodos , Elasticidad , Humanos , Soporte de Peso
8.
Implant Dent ; 24(5): 547-51, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26068320

RESUMEN

PURPOSE: To evaluate the influence of Morse taper implant index on microleakage. MATERIALS AND METHODS: Thirty implants and abutments were divided into 3 groups (n = 10): CM1 (universal post and implant without index), CM2 (universal post and implant with index), and CM3 (abutment and implant with index). To evaluate the microleakage from the implant inner part, the implants were inoculated with Streptococcus sanguinis solution at a 0.5 McFarland and incubated for 7 days at 37°C in Eppendorf tubes with sterile broth. To evaluate the microleakage into the inner part of implant, these were inoculated with sterile Schaedler broth and immersed in a Fusobacterium nucleatum solution at a 0.5 McFarland. The samples were incubated for 30 days in an anaerobic chamber. RESULTS: Nine samples of each group of the first methodology showed no presented bacterial contamination. No samples of the second methodology demonstrated turbidity of the broth. CONCLUSION: The presence of the prosthetic internal index had no influence on bacterial microleakage of Morse taper implants under static conditions, for both methodologies.


Asunto(s)
Diseño de Implante Dental-Pilar/efectos adversos , Implantes Dentales/microbiología , Filtración Dental/microbiología , Contaminación de Equipos , Fusobacterium nucleatum/metabolismo , Humanos , Técnicas In Vitro , Streptococcus sanguis/metabolismo , Microtomografía por Rayos X
9.
J Prosthodont ; 24(2): 168-71, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24990286

RESUMEN

In the event of the loss of an implant and to take advantage of the preexisting structures, a rescue procedure that allows continuous use of the original fixed restoration during the restoration of the tripod support at the implant level can be used. When nonphysiological occlusion forces are avoided, the success rate of this rescue procedure is very similar to any other rehabilitation made following a conventional protocol. Furthermore, the fact that the patient has already adapted to the prosthesis position and its vertical dimension results in easier functional adaptation in the postoperative period and, consequently, greater comfort.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija , Anciano , Fracaso de la Restauración Dental , Femenino , Estudios de Seguimiento , Humanos , Mandíbula/cirugía , Maxilar/cirugía
10.
Gen Dent ; 63(3): 39-42, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25945762

RESUMEN

This in vitro study used microcomputed tomography to evaluate the marginal fit of crowns fabricated using a chairside computer-aided design/computer-aided manufacturing (CAD/CAM) system with different methods of virtual model acquisition. Crowns were fabricated to fit in a cast containing a single human premolar. Four methods of virtual model acquisition were used: Group 1 (control), digital impressioning of a typodont; Group 2, digital impressioning of a powdered typodont; Group 3, digital impressioning of a regular impression; and Group 4, digital impressioning of a master cast. Statistically significant differences were found between the marginal gap of Group 2 and the other groups (P < 0.05); no differences were found among Groups 1, 3, and 4. The results showed that crowns fabricated using the chairside CAD/CAM system exhibited significantly smaller vertical misfit when a thin layer of powder was applied over the typodont before digital impressioning.


Asunto(s)
Diente Premolar/diagnóstico por imagen , Coronas , Adaptación Marginal Dental , Diseño de Prótesis Dental/métodos , Microtomografía por Rayos X , Diente Premolar/cirugía , Diseño Asistido por Computadora , Humanos , Microtomografía por Rayos X/métodos
11.
J Craniofac Surg ; 25(6): 2062-5, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25329843

RESUMEN

This study aims to investigate a possible correlation between vertical misfits and the stresses transmitted to implants from one-piece casted frameworks fabricated with 3 different materials: commercially pure titanium, cobalt chromium alloy, and nickel chromium titanium alloy. Twelve frameworks simulating screw-retained prosthesis were fabricated from a master cast with 5 implants. Each framework was screwed (20 Ncm) over a metal cast and the vertical mesial and distal misfits were measured using an optical microscope. The stresses transmitted to the implants were measured in a third model by a quantitative photoelastic analysis. Stress and vertical misfit data were statistically analyzed by ANOVA and least significant difference tests and the correlation tests were performed using Pearson Correlation Test (α = 0.05). Mean and standard deviation values of vertical misfit and stress over implants are presented, respectively: commercially pure titanium (29.09 ± 13.24 µm and 11.38 ± 9.23 kPa), cobalt chromium alloy (27.05 ± 10.30 µm and 15.83 ± 9.30 kPa), nickel chromium titanium alloy (24.95 ± 11.14 µm and 16.39 ± 9.51 kPa). There were no significant differences for vertical misfit (P = 0.285). Regarding the stress analysis, there were significant differences between commercially pure titanium, cobalt chromium alloy, and nickel chromium titanium alloy (P = 0.035), with the lowest values for the commercially pure titanium. It may be concluded that stress over implants was affected by different procedures and materials for framework production.


Asunto(s)
Mandíbula/anatomía & histología , Diseño de Prótesis/métodos , Análisis de Varianza , Fenómenos Biomecánicos , Aleaciones de Cromo/química , Cobalto/química , Pilares Dentales , Aleaciones Dentales/química , Técnica de Colado Dental , Prótesis Dental de Soporte Implantado , Elasticidad , Humanos , Mandíbula/fisiología , Titanio/química
12.
Implant Dent ; 23(6): 704-9, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25290285

RESUMEN

PURPOSE: To observe the photoelastic stress patterns generated around implants in relation to variations in the diameter and total number of implants supporting fixed complete-arch mandibular frameworks. MATERIALS AND METHODS: Three different implant configurations were analyzed (n = 3): 5 standard implants with diameters of 3.75 mm (C), 3 standard implants with diameters of 3.75 mm (3S), and 3 wide implants with diameters of 5.0 mm (3W). The samples were subjected to a vertical compressive load (1.33 kgf) applied at the end of the distal cantilever of the framework. The shear stresses were calculated around the implants, and the data were analyzed using one-way analysis of variance. RESULTS: The implants nearest to the loading showed higher stress values regardless of the group. The C group showed lower shear stress when compared with the other groups (P = 0.001). No significant difference was observed between the 3W and 3S groups (P = 0.785). CONCLUSION: A reduction in the number of implants, regardless of the implant diameter, showed higher stress concentration around the implants. Five-implant configuration showed lower stress concentration and seems to be more biomechanically predictable.


Asunto(s)
Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental/métodos , Fenómenos Biomecánicos , Fuerza Compresiva , Diseño de Prótesis Dental , Elasticidad , Humanos , Técnicas In Vitro , Mandíbula , Titanio , Torque
13.
J Oral Implantol ; 40(2): 129-35, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22242693

RESUMEN

The aim of this study was to compare vertical and horizontal adjustments of castable abutments after conducting casting and soldering procedures. Twelve external hexagonal implants (3.75 × 10 mm) and their UCLA abutments were divided according their manufacturer and abutment type: PUN (plastic UCLA, Neodent), PUC (plastic UCLA, Conexão), PU3i (plastic UCLA, Biomet 3i), and PUTN (plastic UCLA with Tilite milled base, Neodent). Three infrastructures of a fixed partial implant-supported bridge with 3 elements were produced for each group. The measurements of vertical (VM) and horizontal (HM) misfits were obtained via scanning electron microscopy after completion of casting and soldering. The corresponding values were determined to be biomechanically acceptable to the system, and the results were rated as a percentage. Statistical analysis establishes differences between groups by chi-square after procedures, and McNeman's test was applied to analyze the influence of soldering over casting (α ≤ .05). For the values of VM and HM, respectively, when the casting process was complete, it was observed that 83.25% and 100% (PUTN), 33.3% and 27.75% (PUN), 33.3% and 88.8% (PUC), 33.3% and 94.35% (PU3i) represented acceptable values. After completing the requisite soldering, acceptable values were 50% and 94.35% (PUTN), 16.6% and 77.7% (PUN), 38.55% and 77.7% (PUC), and 27.75% and 94.35% (PU3i). Within the limitations of this study, it can be concluded that the premachined abutments presented more acceptable VM values. The HM values were within acceptable limits before and after the soldering procedure for most groups. Further, the soldering procedure resulted in an increase of VM in all groups.


Asunto(s)
Técnica de Colado Dental , Diseño de Implante Dental-Pilar , Adaptación Marginal Dental , Soldadura Dental/métodos , Aleaciones de Cromo/química , Prótesis Dental de Soporte Implantado , Diseño de Dentadura , Dentadura Parcial Fija , Humanos , Microscopía Electrónica de Rastreo , Estrés Mecánico , Propiedades de Superficie , Torque
14.
J Oral Implantol ; 40(2): 123-8, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22251283

RESUMEN

The purpose of this study was to analyze the influence of the setting and the presence of solid lubricant on the abutment screw surface on the flexural strength of the joint implant/abutment/screw. Forty abutments were connected to external hex implants, divided into 4 groups (n = 10): FE (titanium alloy screw threaded in the extremity), LE (titanium alloy screw with solid lubricant and thread in the extremity), FT (titanium alloy screw with threaded in all its length), and LT (titanium alloy screw with solid lubricant and thread in all its length). Through the mechanical flexural test, the implant/abutment resistance was evaluated with load applied perpendicular to the long axis in a mechanical testing machine (EMIC) under a speed of 0.5 mm/min. Data were submitted to a statistics test, and results showed statistically significant differences between the FE group and the other groups, and the FE group showed the lowest values. The LE group showed greater values than the LT group, and the values were statistically significant. According to the methodology used, it can be concluded that within noncoated titanium screws, a screw threaded along its entire length provided greater rigidity to the implant set, while with the screw containing solid lubricant, the screw threaded in all its length provided less rigidity of the implant set than screws with the thread only on the end. Among screws with the same geometry, those with the solid lubricant are statistically higher than those which do not have threads just at the end, but those with threads along their entire length do not show statistically significant differences.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Pilares Dentales , Diseño de Implante Dental-Pilar , Materiales Dentales/química , Aleaciones Dentales/química , Análisis del Estrés Dental/instrumentación , Humanos , Lubricantes/química , Docilidad , Estrés Mecánico , Propiedades de Superficie , Titanio/química
15.
Int J Prosthodont ; 37(7): 13-17, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38489216

RESUMEN

PURPOSE: To evaluate and compare the accuracy of conventional and 3D-printed casts using five different 3D printers. MATERIALS AND METHODS: In the control group (CG group, n = 5), five conventional impressions using light- and heavy-body polyvinyl siloxane were obtained from the master model, resulting in five stone models. In the test groups, five different scans were performed by a well-trained and experienced clinician using a TRIOS intraoral scanner. All data were exported in STL file format, processed, and sent to five 3D printers. Five casts were manufactured in each printer group: SG (CARES P20, Straumann); FG (Form 2, Formlabs); WG (Duplicator 7, Wanhao); ZG (Zenith D, Zenith); and MG (Moonray S100, Moonray). Measurements of the accuracy (trueness and precision) of the casts obtained from conventional elastomeric impressions and 3D-printing methods were accomplished using a 3D analysis software (Geomagic Control). RESULTS: The FG group showed the lowest values for trueness (indicating a value closer to real dimensions), which were similar to the SG group only (P > .05). MG, WG, and ZG groups presented higher values and were similar compared to each other. Data on precision demonstrated that all 3D-printed groups showed lower values for precision (smaller deviation) when compared to the CG. CONCLUSIONS: The trueness depends on the chosen 3D printer. All of the tested 3D printers were more precise than cast models obtained from conventional elastomeric impressions.


Asunto(s)
Diseño Asistido por Computadora , Implantes Dentales , Impresión Tridimensional , Técnica de Impresión Dental , Imagenología Tridimensional
16.
J Oral Implantol ; 39(4): 483-5, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21905897

RESUMEN

The loss of gingival volume is a major challenge for dental surgeons with implant-supported fixed prosthesis manufactures, particularly from an aesthetics perspective in patients with a high smile line. Gingival tissue remodeling can help in papillae formation to avoid soft tissue surgery by reestablishing the appropriate shape and gingival contour of the tissues. This improves not only the aesthetics, but also the phonetics of the patient. This paper describes a clinical case of gingival conditioning obtained with interim implant-supported fixed partial dentures via incremental addition and adjustment of acrylic resin. The purpose of the gingival conditioning was to obtain improved aesthetics. Gingival conditioning by gradual pressure application is presented as an easy, non-traumatic technique that improves gingival aesthetics.


Asunto(s)
Prótesis Dental de Soporte Implantado , Encía/anatomía & histología , Acondicionamiento de Tejidos Dentales/métodos , Resinas Acrílicas , Dentadura Parcial Fija , Femenino , Humanos , Prótesis Periodontal
17.
Healthcare (Basel) ; 11(18)2023 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-37761669

RESUMEN

This study presented a rehabilitation option for malpositioned implants; this involved obtaining their position and inclination through intraoral scanning, and producing a customized abutment with CAD/CAM technology. The patient in this case report presented a root fracture in tooth 21 and was subjected to extraction, implant installation, and immediate provisional prosthesis. The implant was installed with a distal inclination due to anatomical limitations. After osseointegration, an intraoral scanning transfer provided a digital model (file extension .stl), which reproduced the implant's position and inclination. Then, the file was sent so that a customized abutment (CAD/CAM) could be manufactured, promoting the final rehabilitation of the case; this allowed for good hygiene, load distribution in the dynamic interocclusal relationship, and favorable esthetics, whereas many would otherwise recommend implant removal. The result presented lower costs, a shorter time frame, and a lower morbidity for the patient.

18.
J Oral Implantol ; 38(4): 399-404, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20932125

RESUMEN

The purpose of this study was to warn the dental community about a possible problem in function with partial implant-supported prostheses used for long periods. The misalignment between natural teeth and the implant-supported prosthesis on teeth 11 and 12, observed in a 14-year clinical follow-up, illustrates the fact. The metal-ceramic crowns were placed in 1995 after a rigorous occlusal adjustment. Evaluations were made at 4, 6, 9, and 14 years, when it was noticed that the restorations were positioned palatally and extruded in comparison with the natural teeth. After 9 years, a greater discrepancy was noticed, with anterior occlusion and esthetic changes. The possible causes have been discussed: occlusal problems, parafunctional habits, and natural movement. The first 2 options were discarded after clinical analysis and diagnosis. Therefore, the natural movement probably deriving from an interaction of mechanical and genetic factors might have been the cause. The implants do not have periodontal ligaments but rather ankylosis, so they do not suffer those movements. This case emphasizes the need to inform patients that implants can last more than 10 years in function, but this is not the case with restorations, which lose function and esthetics and must be replaced.


Asunto(s)
Coronas , Arco Dental/patología , Prótesis Dental de Soporte Implantado , Maxilar/patología , Adulto , Implantación Dental Endoósea/métodos , Implantes Dentales , Oclusión Dental , Diseño de Prótesis Dental , Estética Dental , Estudios de Seguimiento , Humanos , Incisivo/lesiones , Arcada Parcialmente Edéntula/rehabilitación , Arcada Parcialmente Edéntula/cirugía , Masculino , Avulsión de Diente/terapia , Fracturas de los Dientes/terapia
19.
Br J Nutr ; 105(7): 990-4, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21129234

RESUMEN

Lower conventional complete dentures were converted to overdentures retained by two implants with an immediately loaded bar-clip system (n 16). The masticatory performance test was carried out using 'Optocal' after forty chewing strokes. Nutritional condition was evaluated by means of a Mini-Nutritional-Assessment questionnaire. No individual was classified as malnourished. The masticatory performance test demonstrated a statistically significant difference before conversion (baseline) and 3 and 6 months after conversion of the lower conventional complete denture to an implant-retained overdenture (paired-samples t test; P < 0·05). A statistically significant difference before and after 6 months of conversion for nutritional condition (Wilcoxon test; P < 0·05) was also observed. The association between masticatory performance and nutritional assessment demonstrated that a statistically significant difference between masticatory performance of the subgroups classified at baseline as nourished (22·43 %) and those at risk of malnutrition (3·9 %) was only evidenced before conversion (P = 0·006). After the conversion from a lower conventional complete denture to an implant-retained overdenture, at 3 months, the risk of malnutrition and nourished at baseline did not present significant differences in masticatory performance. Nonetheless, the mean masticatory performance potential was 19·86 and 31·98 % for subgroups classified at baseline as at risk of malnutrition and nourished, respectively (P = 0·187). The results before conversion were less favourable for masticatory performance and nutritional condition. The increased retention of the mandibular prosthesis allowed improvement in masticatory performance and nutritional condition.


Asunto(s)
Prótesis de Recubrimiento , Desnutrición/prevención & control , Masticación , Evaluación Nutricional , Adulto , Anciano , Dentadura Completa Inferior , Humanos , Desnutrición/etiología , Mandíbula/cirugía , Persona de Mediana Edad , Factores de Riesgo
20.
Dent Mater ; 36(11): e340-e351, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32950244

RESUMEN

OBJECTIVE: To evaluate the effect of exposure time and moving the light-curing unit (LCU) on the degree of conversion (DC) and Knoop microhardness (KH) of two resin cements that were light-cured through ceramic. METHODS: Two resin cements: AllCem Veneer APS (FGM) and Variolink Esthetic LC (Ivoclar Vivadent) were placed into a 0.3 mm thick matrix in 6 locations representing the canine to canine. The resins were covered with 0.5 mm thick lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar Vivadent). A motorized device moved the LCUs over the ceramic when the LCU was on. Two single-peak LCUs: Elipar DeepCure-L (3M Oral Care) and Emitter C (Schuster), and one multi-peak: Bluephase G2 (Ivoclar Vivadent) were used with 3 different exposure protocols: a localized exposure centered over each tooth for 10 or 40 s; moving the tip across the 6 teeth for a total exposure time of 10 or 40 s; and moving the tip across the 6 teeth resins for a total exposure time of 60 or 240 s. After 24 h, the DC and KH were measured on the top surfaces and the data was analyzed using three-way ANOVA and Tukey's tests (α = 0.05). RESULTS: Interposition of 0.5 mm of ceramic reduced the irradiance received by the resin by approximately 50%. The 40 s localized exposure over each tooth always produced significantly higher DC and KH values. Moving the LCUs with a total exposure time of 10 s resulted in the lowest DC and KH. There was no beneficial effect on the DC or KH when the multi-peak (violet-blue) LCU (Elipar DeepCure-L or Bluephase G2), but the lower light output from a small tip LCU reduced the DC and KH values (Emitter C). SIGNIFICANCE: Moving the LCUs when photo-curing light-cured resin cements is not recommended. This study showed that a single-peak LCU could activate a resin cement that uses Ivocerin™ as well as the multi-peak LCU.


Asunto(s)
Luces de Curación Dental , Cementos de Resina , Resinas Compuestas , Dureza , Ensayo de Materiales , Polimerizacion