Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Card Fail ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38750689

RESUMEN

BACKGROUND: The Heart Failure Collaboratory (HFC) score integrates types and dosages of guideline-directed pharmacotherapies for heart failure (HF) with reduced ejection fraction (HFrEF). We examined the effects of cardioverter-defibrillator (ICD) implantation according to the modified HFC (mHFC) score in 1116 patients with nonischemic HFrEF from the Danish Study to Assess the Efficacy of ICDs in Patients with Nonischemic Systolic HF on Mortality (DANISH). METHODS AND RESULTS: Patients were assigned scores for renin-angiotensin-system inhibitors, beta-blockers and mineralocorticoid receptor antagonists (0, no use; 1, < 50% of maximum dosage; 2, ≥ 50% of maximum dosage). The maximum score was 6, corresponding to ≥ 50% of maximum dosage for all therapies. The median baseline mHFC score was 4, and the median follow-up was 9.5 years. Compared with an mHFC score of 3-4, an mHFC score of 1-2 was associated with a higher rate of all-cause death (mHFC = 1-2: adjusted HR 1.67 [95% CI, 1.23-2.28]; mHFC = 3-4, reference; mHFC = 5-6: adjusted HR 1.07 [95% CI, 0.87-1.31]). ICD implantation did not reduce all-cause death compared with control (reference) (HR 0.89 [95% CI, 0.74-1.08]), regardless of mHFC score (mHFC = 1-2: HR 0.98 [95% CI, 0.56-1.71]; mHFC = 3-4: HR 0.89 [95% CI,0.66-1.20]; mHFC = 5-6: HR 0.85 [95% CI, 0.64-1.12]; Pinteraction, 0.65). Similarly, ICD implantation did not reduce cardiovascular death (HR 0.87 [95% CI, 0.70-1.09]), regardless of mHFC score (Pinteraction, 0.59). The ICD group had a lower rate of sudden cardiovascular death (HR, 0.60 [95% CI,0.40-0.92]); this association was not modified by mHFC score (Pinteraction, 0.35). CONCLUSIONS: Lower mHFC scores were associated with higher rates of all-cause death. ICD implantation did not result in an overall survival benefit in patients with nonischemic HFrEF, regardless of mHFC score.

2.
Circulation ; 145(6): 427-436, 2022 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-34882430

RESUMEN

BACKGROUND: DANISH (The Danish Study to Assess the Efficacy of Implantable Cardioverter Defibrillators [ICDs] in Patients With Nonischemic Systolic Heart Failure on Mortality) found that primary-prevention ICD implantation was not associated with an overall survival benefit in patients with nonischemic systolic heart failure during a median follow-up of 5.6 years, although there was a beneficial effect on all-cause mortality in patients ≤70 years. This study presents an additional 4 years of follow-up data from DANISH. METHODS: In DANISH, 556 patients with nonischemic systolic heart failure were randomized to receive an ICD and 560 to receive usual clinical care and followed until June 30, 2016. In this long-term follow-up study, patients were followed until May 18, 2020. Analyses were conducted for the overall population and according to age (≤70 and >70 years). RESULTS: During a median follow-up of 9.5 years (25th-75th percentile, 7.9-10.9 years), 208/556 patients (37%) in the ICD group and 226/560 patients (40%) in the control group died. Compared with the control group, the ICD group did not have significantly lower all-cause mortality (hazard ratio [HR] 0.89, [95% CI, 0.74-1.08]; P = 0.24). In patients ≤70 years (n = 829), all-cause mortality was lower in the ICD group than the control group (117/389 [30%] versus 158/440 [36%]; HR, 0.78 [95% CI, 0.61-0.99]; P = 0.04), whereas in patients >70 years (n = 287), all-cause mortality was not significantly different between the ICD and control group (91/167 [54%] versus 68/120 [57%]; HR, 0.92 [95% CI, 0.67-1.28]; P = 0.75). Cardiovascular death showed similar trends (overall, 147/556 [26%] versus 164/560 [29%]; HR, 0.87 [95% CI, 0.70-1.09]; P = 0.20; ≤70 years, 87/389 [22%] versus 122/440 [28%]; HR, 0.75 [95% CI, 0.57-0.98]; P = 0.04; >70 years, 60/167 [36%] versus 42/120 [35%]; HR, 0.97 [95% CI, 0.65-1.45]; P = 0.91). The ICD group had a significantly lower incidence of sudden cardiovascular death in the overall population (35/556 [6%] versus 57/560 [10%]; HR, 0.60 [95% CI, 0.40-0.92]; P = 0.02) and in patients ≤70 years (19/389 [5%] versus 49/440 [11%]; HR, 0.42 [95% CI, 0.24-0.71]; P = 0.0008), but not in patients >70 years (16/167 [10%] versus 8/120 [7%]; HR, 1.34 [95% CI, 0.56-3.19]; P = 0.39). CONCLUSIONS: During a median follow-up of 9.5 years, ICD implantation did not provide an overall survival benefit in patients with nonischemic systolic heart failure. In patients ≤70 years, ICD implantation was associated with a lower incidence of all-cause mortality, cardiovascular death, and sudden cardiovascular death. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00542945.


Asunto(s)
Desfibriladores Implantables/normas , Insuficiencia Cardíaca Sistólica/epidemiología , Insuficiencia Cardíaca Sistólica/mortalidad , Anciano , Dinamarca , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Análisis de Supervivencia
3.
Circulation ; 145(10): 754-764, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-34889650

RESUMEN

BACKGROUND: Identification of patients with nonischemic cardiomyopathy who may benefit from prophylactic implantation of a cardioverter-defibrillator. We hypothesized that periodic repolarization dynamics (PRD), a marker of repolarization instability associated with sympathetic activity, could be used to identify patients who will benefit from prophylactic implantable cardioverter defibrillator (ICD) implantation. METHODS: We performed a post hoc analysis of DANISH (Danish ICD Study in Patients With Dilated Cardiomyopathy), in which patients with nonischemic cardiomyopathy, left ventricular ejection fraction (LVEF) ≤35%, and elevated NT-proBNP (N-terminal probrain natriuretic peptides) were randomized to ICD implantation or control group. Patients were included in the PRD substudy if they had a 24-hour Holter monitor recording at baseline with technically acceptable ECG signals during the night hours (00:00-06:00). PRD was assessed using wavelet analysis according to previously validated methods. The primary end point was all-cause mortality. Cox regression models were adjusted for age, sex, NT-proBNP, estimated glomerular filtration rate, LVEF, atrial fibrillation, ventricular pacing, diabetes, cardiac resynchronization therapy, and mean heart rate. We proposed PRD ≥10 deg2 as an exploratory cut-off value for ICD implantation. RESULTS: A total of 748 of the 1116 patients in DANISH qualified for the PRD substudy. During a mean follow-up period of 5.1±2.0 years, 82 of 385 patients died in the ICD group and 85 of 363 patients died in the control group (P=0.40). In Cox regression analysis, PRD was independently associated with mortality (hazard ratio [HR], 1.28 [95% CI, 1.09-1.50] per SD increase; P=0.003). PRD was significantly associated with mortality in the control group (HR, 1.51 [95% CI, 1.25-1.81]; P<0.001) but not in the ICD group (HR, 1.04 [95% CI, 0.83-1.54]; P=0.71). There was a significant interaction between PRD and the effect of ICD implantation on mortality (P=0.008), with patients with higher PRD having greater benefit in terms of mortality reduction. ICD implantation was associated with an absolute mortality reduction of 17.5% in the 280 patients with PRD ≥10 deg2 (HR, 0.54 [95% CI, 0.34-0.84]; P=0.006; number needed to treat=6), but not in the 468 patients with PRD <10 deg2 (HR, 1.17 [95% CI, 0.77-1.78]; P=0.46; P for interaction=0.01). CONCLUSIONS: Increased PRD identified patients with nonischemic cardiomyopathy in whom prophylactic ICD implantation led to significant mortality reduction.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Desfibriladores Implantables , Cardiomiopatías/diagnóstico , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/prevención & control , Dinamarca/epidemiología , Humanos , Volumen Sistólico , Función Ventricular Izquierda
4.
Eur Heart J ; 42(21): 2060-2068, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33599276

RESUMEN

AIMS: Atrioventricular block (AVB) of unknown aetiology is rare in the young, and outcome in these patients is unknown. We aimed to assess long-term morbidity and mortality in young patients with AVB of unknown aetiology. METHODS AND RESULTS: We identified all Danish patients younger than 50 years receiving a first pacemaker due to AVB between January 1996 and December 2015. By reviewing medical records, we included patients with AVB of unknown aetiology. A matched control cohort was established. Follow-up was performed using national registries. The primary outcome was a composite endpoint consisting of death, heart failure hospitalization, ventricular tachyarrhythmia, and cardiac arrest with successful resuscitation. We included 517 patients, and 5170 controls. Median age at first pacemaker implantation was 41.3 years [interquartile range (IQR) 32.7-46.2 years]. After a median follow-up of 9.8 years (IQR 5.7-14.5 years), the primary endpoint had occurred in 14.9% of patients and 3.2% of controls [hazard ratio (HR) 3.8; 95% confidence interval (CI) 2.9-5.1; P < 0.001]. Patients with persistent AVB at time of diagnosis had a higher risk of the primary endpoint (HR 10.6; 95% CI 5.7-20.0; P < 0.001), and risk was highest early in the follow-up period (HR 6.8; 95% CI 4.6-10.0; P < 0.001, during 0-5 years of follow-up). CONCLUSION: Atrioventricular block of unknown aetiology presenting before the age of 50 years and treated with pacemaker implantation was associated with a three- to four-fold higher rate of the composite endpoint of death or hospitalization for heart failure, ventricular tachyarrhythmia, or cardiac arrest with successful resuscitation. Patients with persistent AVB were at higher risk. These findings warrant improved follow-up strategies for young patients with AVB of unknown aetiology.


Asunto(s)
Bloqueo Atrioventricular , Insuficiencia Cardíaca , Marcapaso Artificial , Taquicardia Ventricular , Adulto , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Humanos , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Retrospectivos
5.
Sensors (Basel) ; 22(3)2022 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-35161758

RESUMEN

This paper presents methods for continuous condition monitoring of railway switches and crossings (S&C, turnout) via sleeper-mounted accelerometers at the crossing transition. The methods are developed from concurrently measured sleeper accelerations and scanned crossing geometries from six in situ crossing panels. These measurements combined with a multi-body simulation (MBS) model with a structural track model and implemented scanned crossing geometries are used to derive the link between the crossing geometry condition and the resulting track excitation. From this analysis, a crossing condition indicator Cλ1-λ2, Î³ is proposed. The indicator is defined as the root mean square (RMS) of a track response signal γ that has been band-passed between frequencies corresponding to track deformation wavelength bounds of λ1 and λ2 for the vehicle passing speed (f = v/ λ). In this way, the indicator ignores the quasi-static track response with wavelengths predominantly above λ1 and targets the dynamic track response caused by the kinematic wheel-crossing interaction governed by the crossing geometry. For the studied crossing panels, the indicator C1-0.2 m, Î³ (λ1=1 and λ2=0.2) was evaluated for γ = u, v, or a as in displacements, velocities, and accelerations, respectively. It is shown that this condition indicator has a strong correlation with vertical wheel-rail contact forces that is sustained for various track conditions. Further, model calibrations were performed to measured sleeper displacements for the six investigated crossing panels. The calibrated models show (1) a good agreement between measured and simulated sleeper displacements for the lower frequency quasi-static track response and (2) improved agreement for the dynamic track response at higher frequencies. The calibration also improved the agreement between measurements and simulation for the crossing condition indicator demonstrating the value of model calibration for condition monitoring purposes.


Asunto(s)
Vías Férreas , Aceleración , Calibración , Simulación por Computador
6.
Am Heart J ; 232: 61-70, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33144085

RESUMEN

BACKGROUND: Atrial fibrillation (AF) in heart failure (HF) patients has been associated with a worse outcome. Similarly, excessive supraventricular ectopic activity (ESVEA) has been linked to development of AF, stroke, and death. This study aimed to investigate AF and ESVEA's association with outcomes and effect of prophylactic implantable cardioverter defibrillator (ICD) implantation in nonischemic HF patients. METHODS: A total of 850 patients with nonischemic HF, left ventricle ejection fraction ≤35%, and elevated N-terminal pro-brain natriuretic peptides underwent 24 hours Holter recording. The presence of AF (≥30 seconds) and ESVEA (≥30 supraventricular ectopic complexes (SVEC) per hour or run of SVEC ≥20 beats) were registered. Outcomes were all-cause mortality, cardiovascular death (CVD), and sudden cardiac death (SCD). RESULTS: AF was identified in 188 patients (22%) and ESVEA in 84 patients (10%). After 4 years and 11 months of follow-up, a total of 193 patients (23%) had died. AF was associated with all-cause mortality (hazard ratio [HR] 1.44; confidence interval [CI] 1.04-1.99; P = .03) and CVD (HR 1.59; CI 1.07-2.36; P = .02). ESVEA was associated with all-cause mortality (HR 1.73; CI 1.16-2.57; P = .0073) and CVD (HR 1.76; CI 1.06-2.92; P = .03). Neither AF nor ESVEA was associated with SCD. ICD implantation was not associated with an improved prognosis for neither AF (P value for interaction = .17), nor ESVEA (P value for interaction = .68). CONCLUSIONS: Both AF and ESVEA were associated with worsened prognosis in nonischemic HF. However, ICD implantation was not associated with an improved prognosis for either group.


Asunto(s)
Fibrilación Atrial/fisiopatología , Complejos Atriales Prematuros/fisiopatología , Muerte Súbita Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Mortalidad , Anciano , Fibrilación Atrial/complicaciones , Complejos Atriales Prematuros/complicaciones , Enfermedades Cardiovasculares/mortalidad , Causas de Muerte , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Dinamarca , Electrocardiografía Ambulatoria , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Volumen Sistólico
7.
Europace ; 23(4): 587-595, 2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33257933

RESUMEN

AIMS: Improved risk stratification to identify non-ischaemic heart failure patients who will benefit from primary prophylactic implantable cardioverter-defibrillator (ICD) is needed. We examined the potential of ventricular arrhythmia to identify patients who could benefit from an ICD. METHODS AND RESULTS: A total of 850 non-ischaemic systolic heart failure patients with left ventricle ≤35% and elevated N-terminal pro-brain natriuretic peptides had a 24-h Holter monitor recording performed. We examined present non-sustained ventricular tachycardia (NSVT), defined as ≥3 consecutive premature ventricular contractions (PVCs) with a rate of ≥100/min, and number of PVCs per hour stratified into low (<30) and high burden (≥30) groups. Outcome measures were overall mortality, sudden cardiac death (SCD), and cardiovascular death (CVD). In total, 193 patients died, 49 from SCD and 125 from CVD. Non-sustained ventricular tachycardia (365 patients) was significantly associated with increased all-cause mortality [hazard ratio (HR) 1.47; 95% confidence interval (CI) 1.07-2.03; P = 0.02] and to CVD (HR 1.89; CI 1.25-2.87; P = 0.003). High burden PVC (352 patients) was associated with increased all-cause mortality (HR1.38; CI 1.00-1.90; P = 0.046) and with CVD (HR 1.78; CI 1.19-2.66; P = 0.005). There was no statistically significant association with SCD for neither NSVT nor PVC. In interaction analyses, neither NSVT (P = 0.56) nor high burden of PVC (P = 0.97) was associated with survival benefit from ICD implantation. CONCLUSION: Ventricular arrhythmia in non-ischaemic heart failure patients was associated with a worse prognosis but could not be used to stratify patients to ICD implantation.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca Sistólica , Insuficiencia Cardíaca , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Dinamarca/epidemiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Humanos , Prevalencia , Pronóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología
8.
J Cardiovasc Electrophysiol ; 31(11): 2940-2947, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32852869

RESUMEN

INTRODUCTION: Studies have shown an association between the outcome in cardiac resynchronization therapy (CRT) and longer interventricular delay at the site of the left ventricular (LV) lead. Targeted LV lead placement at the latest electrically activated segment increases LV function further as compared with standard treatment. We aimed to determine reproducibility and repeatability of identifying the latest electrically activated segment during mapping of all available coronary sinus (CS) branches in patients receiving CRT. METHODS: We included 35 patients who underwent CRT implantation with protocolled mapping guided LV lead implantation aiming for the site of the latest electrical activation. Three different doctors experienced in electrophysiology and implantation of CRT devices independently measured time interval from the local bipolar right ventricular (RV) electrogram (EGM) to the local unipolar LV EGM at all mapped sites (RV-LV). The segment with the latest electrical activation was defined as the target segment (TS) and the CS tributary containing TS was defined as the target vein (TV). Weighted κ statistics with 95% confidence intervals were computed to assess intra- and interobserver agreement for TS and TV. RESULTS: We mapped 258 segments within 131 veins. Weighted κ values for repeatability were 0.85 (0.81-0.89) for TS and 0.92 (0.89-0.93) for TV, and weighted κ values of interobserver agreement ranged from 0.70 (0.61-0.73) to 0.80 (0.76-0.83) for TS and 0.73 (0.64-0.78) to 0.86 (0.83-0.89) for TV among all three observers. CONCLUSION: The reproducibility and repeatability of identifying the latest electrically activated segment during mapping of all available CS branches in patients receiving CRT range from good to very good.


Asunto(s)
Terapia de Resincronización Cardíaca , Seno Coronario , Insuficiencia Cardíaca , Seno Coronario/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos , Reproducibilidad de los Resultados , Resultado del Tratamiento
9.
Europace ; 22(7): 1026-1035, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32142113

RESUMEN

AIMS: Study sex-differences in efficacy and safety of atrial fibrillation (AF) ablation. METHODS AND RESULTS: We assessed first AF ablation outcomes on continuous anticoagulation in 633 patients [209 (33%) women and 424 (67%) men] in a pre-specified subgroup analysis of the AXAFA-AFNET 5 trial. We compared the primary outcome (death, stroke or transient ischaemic attack, or major bleeding) and secondary outcomes [change in quality of life (QoL) and cognitive function] 3 months after ablation. Women were older (66 vs. 63 years, P < 0.001), more often symptomatic, had lower QoL and a longer history of AF. No sex differences in ablation procedure were found. Women stayed in hospital longer than men (2.1 ± 2.3 vs. 1.6 ± 1.3 days, P = 0.004). The primary outcome occurred in 19 (9.1%) women and 26 (6.1%) men, P = 0.19. Women experienced more bleeding events requiring medical attention (5.7% vs. 2.1%, P = 0.03), while rates of tamponade (1.0% vs. 1.2%) or intracranial haemorrhage (0.5% vs. 0%) did not differ. Improvement in QoL after ablation was similar between the sexes [12-item Short Form Health Survey (SF-12) physical 5.1% and 5.9%, P = 0.26; and SF-12 mental 3.7% and 1.6%, P = 0.17]. At baseline, mild cognitive impairment according to the Montreal Cognitive Assessment (MoCA) was present in 65 (32%) women and 123 (30%) men and declined to 23% for both sexes at end of follow-up. CONCLUSION: Women and men experience similar improvement in QoL and MoCA score after AF ablation on continuous anticoagulation. Longer hospital stay, a trend towards more nuisance bleeds, and a lower overall QoL in women were the main differences observed.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Calidad de Vida , Caracteres Sexuales , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
11.
N Engl J Med ; 375(13): 1221-30, 2016 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-27571011

RESUMEN

BACKGROUND: The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not due to coronary artery disease has been based primarily on subgroup analyses. The management of heart failure has improved since the landmark ICD trials, and many patients now receive cardiac resynchronization therapy (CRT). METHODS: In a randomized, controlled trial, 556 patients with symptomatic systolic heart failure (left ventricular ejection fraction, ≤35%) not caused by coronary artery disease were assigned to receive an ICD, and 560 patients were assigned to receive usual clinical care (control group). In both groups, 58% of the patients received CRT. The primary outcome of the trial was death from any cause. The secondary outcomes were sudden cardiac death and cardiovascular death. RESULTS: After a median follow-up period of 67.6 months, the primary outcome had occurred in 120 patients (21.6%) in the ICD group and in 131 patients (23.4%) in the control group (hazard ratio, 0.87; 95% confidence interval [CI], 0.68 to 1.12; P=0.28). Sudden cardiac death occurred in 24 patients (4.3%) in the ICD group and in 46 patients (8.2%) in the control group (hazard ratio, 0.50; 95% CI, 0.31 to 0.82; P=0.005). Device infection occurred in 27 patients (4.9%) in the ICD group and in 20 patients (3.6%) in the control group (P=0.29). CONCLUSIONS: In this trial, prophylactic ICD implantation in patients with symptomatic systolic heart failure not caused by coronary artery disease was not associated with a significantly lower long-term rate of death from any cause than was usual clinical care. (Funded by Medtronic and others; DANISH ClinicalTrials.gov number, NCT00542945 .).


Asunto(s)
Estimulación Cardíaca Artificial , Desfibriladores Implantables , Insuficiencia Cardíaca Sistólica/terapia , Anciano , Enfermedades Cardiovasculares/mortalidad , Muerte Súbita Cardíaca/epidemiología , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Mortalidad , Volumen Sistólico
12.
Eur J Clin Invest ; 49(6): e13103, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30883728

RESUMEN

BACKGROUND: Only few studies in selected cohorts have examined whether the CHA2 DS2 -VASc score can predict the risk of atrial fibrillation and thromboembolic events in patients without atrial fibrillation. MATERIALS AND METHODS: Patients with coronary angiography performed between 2004 and 2012 were grouped according to CHA2 DS2 -VASc score. We excluded patients with atrial fibrillation, anticoagulant therapy and follow-up <30 days. The endpoints were atrial fibrillation and a composite of ischaemic stroke, transient ischaemic attack and systemic embolism. Event rates per 100 person-years were estimated for each CHA2 DS2 -VASc score (0, 1, 2, 3, 4, and >4). Incidence rate ratios were calculated using low-risk patients (CHA2 DS2 -VASc score 0 in males or 1 in females) as reference. RESULTS: In total, 78 233 patients were included with group sizes varying between 8299 (CHA2 DS2 -VASc >4) and 19 882 (CHA2 DS2 -VASc 2). An increasing CHA2 DS2 -VASc score was significantly associated with a future diagnosis of atrial fibrillation (P for trend <0.0001) and an incremental risk of ischaemic stroke, transient ischaemic attack, systemic embolism (P for trend <0.0001) and all-cause death (P for trend <0.0001). Patients with a CHA2 DS2 -VASc score of 3 had a rate of ischaemic stroke/transient ischaemic attack/systemic embolism of 1.30 per 100 person-years. CONCLUSIONS: Among patients undergoing coronary angiography, the CHA2 DS2 -VASc score predicted a future diagnosis of atrial fibrillation and the composite risk of ischaemic stroke, transient ischaemic attack or systemic embolism in patients without atrial fibrillation. A CHA2 DS2 -VASc score of 3 was associated with a risk that would justify prophylactic oral anticoagulation treatment in a patient with atrial fibrillation.

13.
Europace ; 21(11): 1710-1716, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31424500

RESUMEN

AIMS: To describe aetiologies and temporal trends in young patients with atrioventricular block (AVB). METHODS AND RESULTS: We identified all patients in Denmark, receiving their first pacemaker because of AVB before the age of 50 years between 1996 and 2015. Medical records were reviewed and clinical information and diagnostic work-up results were obtained to evaluate the aetiology. We used Poisson regression testing for temporal trends. One thousand and twenty-seven patients were identified, median age at time of implantation was 38 (interquartile range 25-45) years, 584 (56.9%) were male. The aetiologies were complications to cardiac surgery [n = 157 (15.3%)], congenital AVB [n = 93 (9.0%)], cardioinhibitory reflex [n = 52 (5.0%)], congenital heart disease [n = 43 (4.2%)], complication to radiofrequency ablation [n = 35 (3.4%)], cardiomyopathy [n = 31 (3.0%)], endocarditis [n = 18 (1.7%)], muscular dystrophy [n = 14 (1.4%)], ischaemic heart disease [n = 14 (1.4%)], sarcoidosis [n = 11 (1.1%)], borreliosis [n = 9 (0.9%)], hereditary [n = 6 (0.6%)], side-effect to antiarrhythmics [n = 6 (0.6%)], planned His-ablation [n = 5 (0.5%)], complication to alcohol septal ablation [n = 5 (0.5%)], and other known aetiologies [n = 11 (1.1%)]. The aetiology remained unknown in 517 (50.3%) cases. While the number of patients with unknown aetiology increased during the study period (P < 0.001), we observed no significant change in the number of patients with identified aetiology (P = 0.35). CONCLUSION: In a nationwide cohort, the aetiology of AVB was identified in only half the patients younger than 50 years referred for first-time pacemaker implantation. The number of patients with unknown aetiology increased during the study period. These findings indicate need for better insight into aetiologies of AVB and improved diagnostic work-up guidelines.


Asunto(s)
Bloqueo Atrioventricular/terapia , Electrocardiografía , Predicción , Marcapaso Artificial/estadística & datos numéricos , Adulto , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/fisiopatología , Dinamarca/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo
14.
Europace ; 21(3): 465-474, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30535192

RESUMEN

AIMS: Patients with cancer are insufficiently represented in randomized clinical trials investigating efficacy of implantable cardioverter-defibrillators (ICDs). We aimed to describe outcomes in patients with a pre-existing diagnosis of cancer at time of ICD implantation. METHODS AND RESULTS: We utilized Danish nationwide registries to identify primary and secondary prevention ICD implantations from 2007 to 2012. Multivariable Cox models were used to assess the risk of appropriate ICD therapy and mortality in patients with and without cancer at time of implantation. During a median follow-up of 2.1 years, 2935 primary prevention ICD and 2730 secondary prevention ICD implantations were identified. Out of these [289 (5.1%)] had pre-existing cancer [primary 140 (4.8%), secondary 149 (5.5%)]. No differential risk for appropriate ICD therapy was found between patients with or without cancer, [primary cancer: 19/140, no cancer: 380/2795, hazard ratio (HR) = 1.07 (0.67-1.69)] and [secondary cancer: 42/149, no cancer: 699/2581, HR = 1.28 (0.93-1.75)]. In primary patients, cancer was not associated with higher risk of 1-year [cancer: 10/140, no cancer: 133/2795, HR = 1.20 (0.84-2.28)] or all-time mortality [cancer: 22/140, no cancer: 339/2795, HR = 1.13 (0.74-1.75)]. In secondary patients, cancer was associated with a higher 1-year [cancer: 19/149, no cancer: 108/2581, HR = 2.62 (1.60-4.29)] and all-time mortality [cancer: 44/149, no cancer: 315/2581, HR = 2.36 (1.71-3.24)]. CONCLUSION: Implantable cardioverter-defibrillators were implanted in a minority of cancer patients. No difference in risk of appropriate therapy was observed between cancer and non-cancer patients, regardless of implant indication. Cancer was associated with increased mortality in secondary prevention ICD patients, but not in primary prevention ICD patients. In secondary prevention ICD patients, the majority of deaths were attributable to cancer.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Cardiopatías/terapia , Neoplasias/epidemiología , Prevención Primaria/instrumentación , Prevención Secundaria/instrumentación , Anciano , Muerte Súbita Cardíaca/epidemiología , Dinamarca/epidemiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Cardiopatías/diagnóstico , Cardiopatías/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Neoplasias/diagnóstico , Neoplasias/mortalidad , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
Europace ; 21(12): 1919-1927, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31545375

RESUMEN

AIMS: Contact force (CF) between radiofrequency (RF) ablation catheter and myocardium and ablation index (AI) correlates with RF lesion depth and width in normal-voltage (>1.5 mV) myocardium (NVM). We investigate the impact of CF on RF lesion depth and width in low (<0.5 mV) (LVM) and intermediate-voltage (0.5-1.5 mV) myocardium (IVM) following myocardial infarction. Correlation between RF lesion depth and width evaluated by native contrast magnetic resonance imaging (ncMRI) and gross anatomical evaluation was investigated. METHODS AND RESULTS: Twelve weeks after myocardial infarction, 10 pigs underwent electroanatomical mapping and endocardial RF ablations were deployed in NVM, IVM, and LVM myocardium. In vivo ncMRI was performed before the heart was excised and subjected to gross anatomical evaluation. Ninety (82%) RF lesions were evaluated. Radiofrequency lesion depth and width were smaller in IVM and LVM compared with NVM (P < 0.001). Radiofrequency lesion depth and width correlated with CF, AI, and impedance drop in NVM (CF and AI P < 0.001) and IVM (CF and AI depths P < 0.001; CF and AI widths P < 0.05). Native contrast magnetic resonance imaging evaluated RF lesion depth and width correlated with gross anatomical depth and width (NVM and IVM P < 0.001; LVM P < 0.05). CONCLUSIONS: Radiofrequency lesions deployed by similar duration, power and CF are smaller in IVM and LVM than in NVM. Radiofrequency lesion depth and width correlated with CF, AI, and impedance drop in NVM and IVM but not in LVM. Native contrast magnetic resonance imaging may be useful to assess RF lesion depth and width in NVM, IVM, and LVM.


Asunto(s)
Ablación por Catéter/métodos , Cicatriz/fisiopatología , Corazón/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Miocardio/patología , Taquicardia Ventricular/cirugía , Animales , Procedimientos Quirúrgicos Cardíacos , Cicatriz/diagnóstico por imagen , Cicatriz/patología , Impedancia Eléctrica , Técnicas Electrofisiológicas Cardíacas , Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Recurrencia , Sus scrofa , Porcinos , Taquicardia Ventricular/fisiopatología , Insuficiencia del Tratamiento
16.
Europace ; 21(8): 1203-1210, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31323662

RESUMEN

AIMS: Implantable cardioverter-defibrillator (ICD) implantation reduce the risk of sudden cardiac death, but not all-cause death in patients with non-ischaemic systolic heart failure (HF). Whether co-existence of diabetes affects ICD treatment effects is unclear. METHODS AND RESULTS: We examined the effect of ICD implantation on risk of all-cause death, cardiovascular death, and sudden cardiac death (SCD) according to diabetes status at baseline in the Danish Study to Assess the Efficacy of ICDs in Patients with Non-ischaemic Systolic Heart Failure on Mortality (DANISH) trial. Outcomes were analysed by use of cumulative incidence curves and Cox regressions models. Of the 1116 patients enrolled, 211 (19%) had diabetes at baseline. Patients with diabetes were more obese, had worse kidney function and more were in New York Heart Association Class III/IV. The risk of device infections and other complications in the ICD group was similar among patients with and without diabetes (6.1% vs. 4.6% P = 0.54). Irrespective of treatment group, diabetes was associated with higher risk of all-cause death, cardiovascular death, and SCD. The treatment effect of ICD in patients with diabetes vs. patients without diabetes was hazard ratio (HR) = 0.92 (0.57-1.50) vs. HR = 0.85 (0.63-1.13); Pinteraction = 0.60 for all-cause mortality, HR = 0.99 (0.58-1.70) vs. HR = 0.70 (0.48-1.01); Pinteraction = 0.25 for cardiovascular death, and HR = 0.81 (0.35-1.88) vs. HR = 0.40 (0.22-0.76); Pinteraction = 0.16 for sudden cardiac death. CONCLUSION: Among patients with non-ischaemic systolic HF, diabetes was associated with higher incidence of all-cause mortality, primarily driven by cardiovascular mortality including SCD. Treatment effect of ICD therapy was not significantly modified by diabetes which might be due to lack of power.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Diabetes Mellitus/epidemiología , Insuficiencia Cardíaca Sistólica , Implantación de Prótesis , Infecciones Relacionadas con Prótesis , Causas de Muerte , Comorbilidad , Muerte Súbita Cardíaca/etiología , Dinamarca/epidemiología , Femenino , Insuficiencia Cardíaca Sistólica/etiología , Insuficiencia Cardíaca Sistólica/mortalidad , Insuficiencia Cardíaca Sistólica/terapia , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Mortalidad , Evaluación de Resultado en la Atención de Salud , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Medición de Riesgo/métodos , Factores de Riesgo
17.
Europace ; 21(6): 900-908, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-30796456

RESUMEN

AIM: The Danish Study to Assess the Efficacy of Implantable Cardioverter-Defibrillators (ICD) in Patients with Non-ischaemic Systolic Heart Failure (HF) on Mortality (DANISH) found no overall effect on all-cause mortality. The effect of ICD implantation on health-related quality of life (HRQoL) remains to be established as previous trials have demonstrated conflicting results. We investigated the impact of ICD implantation on HRQoL in patients with non-ischaemic systolic HF, a prespecified secondary endpoint in DANISH. METHODS AND RESULTS: In DANISH, a total of 1116 patients with non-ischaemic systolic HF were randomly assigned (1:1) to ICD implantation or usual clinical care (control). Patients completed disease-specific HRQoL as assessed by Minnesota Living with Heart Failure Questionnaire (MLHFQ; 0-105, high indicating worse). Changes in HRQoL 8 months after randomization were assessed with a mixed-effects model. At randomization, MLHFQ was completed by 935 (84%) patients (n = 472 in the ICD group and n = 463 in the control group) and was reassessed in 274 (58%) and 292 (63%) patients, respectively after 8 months for the primary analysis. Patients in the ICD group vs. the control group had similar improvements in MLHFQ after 8 months [least square mean -7.0 vs. -4.2 (P = 0.13)]. A clinically relevant improvement (decrease ≥5) in the MLHFQ overall score at 8 months was observed in 151 patients in the ICD group and 148 patients in the control group [55% vs. 51%, respectively (P = 0.25)]. CONCLUSION: Implantable cardioverter-defibrillator implantation in patients with non-ischaemic systolic HF did not significantly alter HRQoL compared with patients randomized to usual clinical care.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca/prevención & control , Calidad de Vida , Anciano , Dinamarca , Femenino , Humanos , Masculino , Persona de Mediana Edad
18.
Qual Life Res ; 28(11): 2901-2908, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31292822

RESUMEN

PURPOSE: The "distressed" (Type D) personality trait has been reported to be over-represented in patients with heart failure (HF) compared to the background population and may provide prognostic information for mortality. We examined the association between Type D personality and outcomes in the DANISH trial (The Danish Study to Assess the Efficacy of Implantable Cardioverter Defibrillators in Patients with Non-ischemic Systolic Heart Failure on Mortality). METHODS: The DANISH trial included a total of 1116 patients with non-ischemic HF on guideline-recommended therapy. Type D personality was assessed with the Type D Scale (DS14) at baseline and investigated through follow-up accordingly. Multivariable Cox proportional hazard models were used to compare hazard ratios (HR) of cardiovascular and all-cause mortality. RESULTS: Type D personality assessment was completed by 873 (78%) patients at baseline and Type D personality was found in 120 (14%) patients. The median follow-up was 67 months (interquartile range [IQR] 48-83). Among patients with versus without Type D personality, 22% versus 19% died from all-cause yielding similar incidence rates of 4.62 (95% CI 3.14-6.87) versus 3.95 (95% CI 3.37-4.66) per 100 person-years. The adjusted risk of all-cause mortality was not significantly different in patients with versus without Type D personality with an adjusted HR of 1.31 (95% CI 0.84-2.03, p = 0.23) with similar results for cardiovascular death (HR 1.46 (95% CI 0.88-2.44, p = 0.15). CONCLUSION: Type D personality was not significantly associated with increased risk of all-cause mortality or cardiovascular death in patients with non-ischemic HF.


Asunto(s)
Desfibriladores Implantables/normas , Insuficiencia Cardíaca/psicología , Calidad de Vida/psicología , Personalidad Tipo D , Anciano , Femenino , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Factores de Riesgo
19.
J Comput Assist Tomogr ; 43(2): 312-316, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30407247

RESUMEN

OBJECTIVES: Before cardiac resynchronization therapy (CRT) implantation, cardiac computed tomography (CT) can provide assessment of cardiac venous anatomy and visualize left ventricular (LV) myocardial scar. We hypothesized that localization and burden of transmural myocardial scar verified by cardiac CT are associated with echocardiographic and clinical response to CRT. METHODS: We prospectively included 140 CRT recipients undergoing preimplant cardiac CT. We assessed transmural scar, defined as hypoperfusion involving more than one-half of the myocardial wall in each LV segment using a 17-segment model. Echocardiographic nonresponse was defined as less than 5% absolute improvement in LV ejection fraction at 6 months' follow-up. Clinical nonresponse was defined as 1 or more of the following at 6 months' follow-up: death, heart failure hospitalization, or no improvement in New York Heart Association class and less than 10% increase in 6-minute walk-test distance. RESULTS: Higher burden of myocardial scar was associated with echocardiographic nonresponse (adjusted odds ratio, 3.02; 95% confidence interval, 1.03-8.91; P = 0.045). Scar concordant or adjacent to LV pacing site was associated with echocardiographic nonresponse (adjusted odds ratio, 8.2; 95% confidence interval, 1.51-44.27; P = 0.015). No association between scar and clinical nonresponse was demonstrated. CONCLUSIONS: Higher scar burden and scar in proximity to the LV pacing site assessed by cardiac CT are associated with echocardiographic nonresponse to CRT. Burden and location of scar were not associated with clinical nonresponse. Further large-scale studies are needed to assess the potential association between myocardial scar detected by cardiac CT and clinical CRT outcome.


Asunto(s)
Terapia de Resincronización Cardíaca , Cicatriz/diagnóstico por imagen , Ecocardiografía , Insuficiencia Cardíaca/terapia , Corazón/fisiopatología , Miocardio/patología , Tomografía Computarizada por Rayos X/métodos , Anciano , Cicatriz/patología , Femenino , Estudios de Seguimiento , Corazón/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento
20.
Circulation ; 136(19): 1772-1780, 2017 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-28877914

RESUMEN

BACKGROUND: The DANISH study (Danish Study to Assess the Efficacy of ICDs [Implantable Cardioverter Defibrillators] in Patients With Non-Ischemic Systolic Heart Failure on Mortality) did not demonstrate an overall effect on all-cause mortality with ICD implantation. However, the prespecified subgroup analysis suggested a possible age-dependent association between ICD implantation and mortality with survival benefit seen only in the youngest patients. The nature of this relationship between age and outcome of a primary prevention ICD in patients with nonischemic systolic heart failure warrants further investigation. METHODS: All 1116 patients from the DANISH study were included in this prespecified subgroup analysis. We assessed the relationship between ICD implantation and mortality by age, and an optimal age cutoff was estimated nonparametrically with selection impact curves. Modes of death were divided into sudden cardiac death and nonsudden death and compared between patients younger and older than this age cutoff with the use of χ2 analysis. RESULTS: Median age of the study population was 63 years (range, 21-84 years). There was a linearly decreasing relationship between ICD and mortality with age (hazard ratio [HR], 1.03; 95% confidence interval [CI], 1.003-1.06; P=0.03). An optimal age cutoff for ICD implantation was present at ≤70 years. There was an association between reduced all-cause mortality and ICD in patients ≤70 years of age (HR, 0.70; 95% CI, 0.51-0.96; P=0.03) but not in patients >70 years of age (HR, 1.05; 95% CI, 0.68-1.62; P=0.84). For patients ≤70 years old, the sudden cardiac death rate was 1.8 (95% CI, 1.3-2.5) and nonsudden death rate was 2.7 (95% CI, 2.1-3.5) events per 100 patient-years, whereas for patients >70 years old, the sudden cardiac death rate was 1.6 (95% CI, 0.8-3.2) and nonsudden death rate was 5.4 (95% CI, 3.7-7.8) events per 100 patient-years. This difference in modes of death between the 2 age groups was statistically significant (P=0.01). CONCLUSIONS: In patients with systolic heart failure not caused by ischemic heart disease, the association between the ICD and survival decreased linearly with increasing age. In this study population, an age cutoff for ICD implantation at ≤70 years yielded the highest survival for the population as a whole. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00542945.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca Sistólica/terapia , Prevención Primaria/instrumentación , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Muerte Súbita Cardíaca/etiología , Dinamarca , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Insuficiencia Cardíaca Sistólica/diagnóstico , Insuficiencia Cardíaca Sistólica/etiología , Insuficiencia Cardíaca Sistólica/mortalidad , Humanos , Estimación de Kaplan-Meier , Modelos Lineales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA