Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Diabetes Spectr ; 37(2): 124-129, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38756425

RESUMEN

Objective: The aim of this study was to assess the extent of nondisclosure of type 1 diabetes in adolescents and investigate its association with several psychosocial parameters and clinical outcomes. Research design and methods: This was a cross-sectional study based on data collected from 69 adolescents with type 1 diabetes who were 12-18 years of age and followed at our diabetes clinic. The degree of disclosure, demographics, diabetes management, and psychosocial issues were assessed via questionnaires. Clinical parameters were derived from medical records. Associations between nondisclosure status and clinical and psychosocial study variables were assessed. Results: Fifty-three participants (77%) reported some extent of nondisclosure. Nondisclosure was associated with low self-esteem, reduced friend support, and increased diabetes-related worries. Nondisclosure was also found to be associated with diminished self-care behaviors related to insulin administration and with elevated A1C. Conclusion: Our results demonstrate that nondisclosure of type 1 diabetes in adolescents may be more common than initially recognized and is likely associated with unfavorable psychological outcomes and reduced self-care and diabetes management. Our results emphasize the importance of social interactions and disclosure in adolescents and may serve as a potential stepping stone to address other social barriers hindering diabetes management.

2.
Am J Ther ; 27(1): e30-e41, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31833871

RESUMEN

BACKGROUND: Advances in pump technology have increased the popularity of this treatment modality among patients with type 1 diabetes and recently also among patients with type 2 diabetes. AREAS OF UNCERTAINTY: Four decades after the incorporation of the insulin pump in clinical use, questions regarding its efficacy, occurrence rate of short-term complications as hypoglycemia and diabetes ketoacidosis, timing of pump initiation, and selected populations for use remain unanswered. DATA SOURCES: A review of the literature was performed using the PubMed database to identify all articles published up till December 2018, with the search terms including insulin pump therapy/continuous subcutaneous insulin delivery. The Cochrane database was searched for meta-analysis evaluating controlled randomized trials. Consensuses guidelines published by the International Society for Pediatric and Adolescent Diabetes, American Diabetes Association, and Advanced Technologies and Treatments for Diabetes year books were additionally reviewed for relevant cited articles. THERAPEUTIC ADVANCES: Insulin pump therapy offers flexible management of diabetes. It enables adjustment of basal insulin to daily requirements and circadian needs, offers more precise treatment for meals and physical activity, and, when integrated with continuous glucose monitoring, allows glucose responsive insulin delivery. The ability to download and transmit data for analysis allow for treatment optimization. Newer pumps are simple to operate and increase user experience. Studies support the efficacy of pump therapy in improving glycemic control and reducing the occurrence of hypoglycemia without increasing episodes of diabetes ketoacidosis. They also improve quality of life. Recent evidence suggests a role for pump therapy in reducing microvascular and macrovascular diabetes-related complications. CONCLUSIONS: Insulin pump therapy appears to be effective and safe in people with T1D regardless of age. Future advancements will include incorporation of closed loop and various decision support systems to aid and improve metabolic control and quality of life.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Sistemas de Liberación de Medicamentos , Hemoglobina Glucada , Humanos , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Calidad de Vida
3.
Diabetes Obes Metab ; 21(4): 822-828, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30478937

RESUMEN

AIMS: Previous DREAM studies demonstrated the safety and efficacy of the CE marked MD-Logic closed-loop system (DreaMed GlucoSitter) in different settings for overnight glycaemic control. The present study aimed to evaluate the system for day and night use for 60 hours during the weekend at home compared to sensor-augmented pump (SAP) therapy in participants with type 1 diabetes. METHODS: This was a prospective, multicentre, crossover, controlled study (clinicaltrials.gov NCT01238406). All participants were connected in randomized order for one weekend to SAP therapy or the MD-Logic System. In the intervention arm only, the amount of carbohydrate was entered into the bolus calculator; the rest of insulin delivery was automated and wireless via a tablet computer. The primary endpoint was percentage of glucose values between 70 and 180 mg/dL. RESULTS: The ITT population comprised 48 (19 males, 29 females) adolescents and adults experienced in sensor use: (median, [IQR]): age, 16.1years [13.2-18.5]; diabetes duration, 9.4 years [5.0-12.7]; pump use, 5.4 years [3.1-9.4]; HbA1c, 7.6% [7.0-8.1]. A significant increase in the percentage of time within target range (70-180 mg/dL) (66.6% vs 59.9%, P = 0.002) was observed with the closed-loop system vs control weekends with unchanged percentage of time below 70 mg/dL (2.3% vs 1.5%, P = 0.369). Mean weekend glucose level per participant was significantly lower (153 [142-175] vs 164 [150-186] mg/dL, P = 0.003). No safety signals were observed. CONCLUSIONS: The MD-Logic system was safe and associated with better glycaemic control than SAP therapy for day and night use. The absence of remote monitoring did not lead to safety signals in adapting basal rates nor in administration of automated bolus corrections.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Adolescente , Ritmo Circadiano , Estudios Cruzados , Diabetes Mellitus Tipo 1/metabolismo , Femenino , Lógica Difusa , Humanos , Hipoglucemia/inducido químicamente , Masculino , Monitoreo Ambulatorio , Adulto Joven
4.
Endocrine ; 84(3): 943-950, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38225516

RESUMEN

PURPOSE: In recent years there has been a noticeable increase in the use of advanced hybrid closed-loop systems (AHCLs) for managing type 1 diabetes (T1D) among youth. However, there is a lack of comparison between the open-source automated insulin delivery (AID) system and the MiniMed™ 780 G system (780 G). METHODS: In this multi-center study, we retrospectively compared selected glycemic ranges of 26 individuals who used open-source AID and 20 individuals who used 780 G (age 11.3 years [IQR 9.3, 12.9] and 13.4 years [IQR 10.9, 16.5], respectively, p = 0.069) from system initiation to the most recent visit. RESULTS: At baseline, the median HbA1c was significantly lower and the time below range (TBR)<54mg/dL was significantly higher in the open-source AID group compared to the 780 G group (6.8% [IQR 6.4, 7.1] vs. 7.4% [IQR 6.9, 8.6], p = 0.006 and (1.0% [IQR 0.5, 2.8] vs. 0.0% [0.0, 1.0], p = 0.014), respectively; the median time in range (TIR70-180mg/dL) was similar (p = 0.068). After a median duration of 10.9 months on AHCLs the reduction of HbA1c was similar ( ~ 0.3%). The time spent in the hypoglycemic ranges was longer among users of the open-source AID compared to 780 G (TBR54-70mg/dL 4.2% [IQR 2.6, 7.3] vs. 2.0% [1.0, 4.0], p = 0.005) and TBR<54mg/dL 1.1% [IQR 0.4, 2.3] vs. 0.0 [0.0, 1.0], p = 0.001). CONCLUSIONS: Both AHCLs similarly improved HbA1c and TIR70-180mg/dL. The open-source AID youth had better glycemic control but spent longer time in the hypoglycemic range. These findings must be considered when choosing the use of AHCL technologies.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Adolescente , Niño , Masculino , Femenino , Insulina/administración & dosificación , Insulina/uso terapéutico , Estudios Retrospectivos , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Glucemia/análisis , Hemoglobina Glucada/análisis , Automonitorización de la Glucosa Sanguínea/métodos
5.
Artículo en Inglés | MEDLINE | ID: mdl-39008607

RESUMEN

CONTEXT: Central congenital hypothyroidism (CCH) is a thyroid hormone deficiency at birth caused by inadequate pituitary stimulation of the thyroid gland. Although primary CH has been studied extensively, studies on CCH are sparse. OBJECTIVES: To assess the prevalence of CCH in Israel and describe its clinical features, neonatal screening results, and outcomes. DESIGN: Multicenter cross-sectional retrospective chart review. SETTING: Nine pediatric endocrine units throughout Israel. PATIENTS: Patients diagnosed with CCH in 1987-2021 were categorized into early (within 14 days of life) and late (after 14 days) diagnosis groups. Newborn screening (NBS) results were retrospectively retrieved from the national NBS program dataset. RESULTS: CCH prevalence in Israel was about 1:42,800 live births. Subjects were 94 patients (54 males), of these, 84% had multiple pituitary hormone deficiencies and 16% had isolated CCH. The median age at diagnosis was 50 days (range, 1-8760), with 66% having moderate to severe hypothyroidism. NBS detected only three infants. Early diagnosis occurred in 34% due to hypopituitarism, while 66% were diagnosed later due to growth and developmental delays. Neurodevelopmental sequelae included mental retardation (12%), learning difficulties (18%), delayed speech (27%), and motor clumsiness (19%), with no significant differences in outcomes between early and late diagnosis. CONCLUSIONS: Despite high rates of neurodevelopmental sequelae, no differences were found between early and late diagnosis groups. Further research is needed to assess the impact of delayed diagnosis on neurological outcomes in newborns with CCH. Improved strategies for detecting CHH in newborns are also necessary.

6.
Endocrine ; 81(2): 262-269, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37222881

RESUMEN

PURPOSE: The use of open-source automated insulin delivery systems (OS-AIDs), for the management of type 1 diabetes (T1D), has increased over recent years in all age groups. Real-life data has demonstrated the safety and efficacy of these systems, however, studies in the pediatric population remain limited. In this study, we aimed to examine the effect of transition to an OS-AIDs on glycemic parameters, and on several aspects related to quality of life. In addition, we aimed to characterize the socioeconomic position of families who chose this treatment modality, assess their motivations to do so, and evaluate treatment satisfaction. METHODS: In this multi-center observational real-life study from the AWeSoMe Group, we compared glycemic parameters of 52 individuals with T1D (56% males, mean diabetes duration 4.2 ± 3.9 years), from the last clinic visit prior to OS-AIDs initiation to the most recent clinic visit while using the system. Socioeconomic position (SEP) index was retrieved from the Israel Central Bureau of Statistics. Caregivers completed questionnaires assessing reasons for system initiation and treatment satisfaction. RESULTS: Mean age at OS-AIDs initiation was 11.2 ± 4 years, range 3.3-20.7 years with a median usage duration of 11.1 months (range 3-45.7). Mean SEP Index was 1.033 ± 0.956 (value range: -2.797 to 2.590). Time in range (TIR) of 70 to 180 mg/dl increased from 69.0 ± 11.9 to 75.5 ± 11.7%, (P < 0.001), and HbA1c decreased from 6.9 ± 0.7 to 6.4 ± 0.6%, (P < 0.001). Time in tight range (TITR) of 70 to 140 mg/dl increased from 49.7 ± 12.9 to 58.8 ± 10.8% (P < 0.001). No episodes of severe hypoglycemia or DKA were reported. Reduction in diabetes burden and sleep quality improvement were the main reasons for OS-AID initiation. CONCLUSIONS: In our cohort of youth with T1D, the transition to an OS-AID resulted in greater TIR and less severe hypoglycemia regardless of age, diabetes duration or SEP, which was found to be above average. The overall improvement in glycemic parameters in our study population with excellent baseline glycemic control, provides additional evidence of beneficence and efficacy of OS-AIDs in the pediatric population.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Masculino , Adolescente , Humanos , Niño , Lactante , Femenino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Calidad de Vida , Insulina/uso terapéutico , Encuestas y Cuestionarios , Automonitorización de la Glucosa Sanguínea , Hipoglucemiantes/uso terapéutico , Glucemia , Sistemas de Infusión de Insulina
7.
Diabetes Technol Ther ; 23(4): 268-276, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33185480

RESUMEN

Background: The Medtronic MiniMed™ 670G system adjusts basal insulin delivery in response to continuous glucose monitoring levels and is already in use in clinical practice. We tested the home-based feasibility of the new MiniMed advanced hybrid closed-loop (AHCL) system, which includes several algorithm enhancements and an optional autocorrection bolus mode. Methods: Twelve adolescents and young adults (eight females) with type 1 diabetes [median (interquartile range)] aged 16.6 (15.9, 18.2) years and diabetes duration of 7.1 (4.7, 8.8) years] participated in this single-arm study. The first stage was a 6-day open-loop run-in period, with the predictive low-glucose suspend feature on. This was followed by 6 days/5 nights in a supervised hotel setting, using the AHCL system, including closed-loop challenges (missed meal bolus, late meal bolus, and physical activity); and finally, 3 weeks with unrestricted home use. Glycemic parameters were compared between the open-loop and closed-loop periods. Results: Participants spent 93.3% (4.7) of the time in SmartGuard™ Auto Mode. Hemoglobin A1C levels decreased from median (interquartile range) 7.1% (6.7, 7.9) at baseline to 6.8% (6.6, 7.4) at study end, after 4 weeks (P = 0.0027). Time in range (TIR) (70-180 mg/dL) was 68.4% (10.6) and time below 70 mg/dL was 4% (3.5) during open-loop; and 74% (6.1) and 2.6% (1.9), respectively, during the closed-loop at home phase (P = 0.06, P = 0.27). TIR increased during the nighttime, from 64.6% (17.4) to 80.7% (7.8), P = 0.007, without change in time below 70 mg/dL (P = 0.15). No serious adverse events occurred. Conclusions: The new AHCL system demonstrated safety and effectiveness in controlling day and night glucose levels.


Asunto(s)
Diabetes Mellitus Tipo 1 , Sistemas de Infusión de Insulina , Insulina , Adolescente , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Estudios de Factibilidad , Femenino , Humanos , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/uso terapéutico , Masculino
8.
J Pediatr Gastroenterol Nutr ; 50(2): 173-8, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19668004

RESUMEN

OBJECTIVES: Patients with cystic fibrosis (CF) presenting with meconium ileus (MI) tend to have worse outcomes than those without MI. We evaluated the clinical characteristics and survival rates among Israeli patients with CF with and without MI after a prolonged follow-up (15-30 years). PATIENTS AND METHODS: A multicenter retrospective study. Forty-nine patients with CF, representing 13.8% of all patients with CF in Israel, presented with MI (current age 17.4 +/- 7.9 years) between 1975 and 2006. They were compared with 38 patients with CF (current age 19.3 +/- 6.5 years) without MI matched by sex and CF transmembrane conductance regulator mutation. RESULTS: A total of 66.2% of patients with MI and 73.6% without MI were followed for a prolonged period (24.9 +/- 2.7 years). Of the patients with MI, 31 were managed operatively, whereas 18 were treated successfully with gastrograffin enema, with similar clinical outcomes. Five patients in the MI group and 3 in the control group died during the study period. Bacterial colonization, z score of body mass index, and pulmonary function tests were similar in patients with and without MI in the long term. In younger patients, many clinical parameters were more prevalent in patients with MI (P = 0.004). However, these differences disappeared after the long-term follow-up (up to 31-years). CONCLUSIONS: Patients with CF presenting with MI had similar pulmonary function and nutritional status, as well as survival rates as did the control patients without MI. The distinct genetic mutation found in our population may explain in part the favorable results compared with other studies. In addition, it seems that early diagnosis and treatment of MI in patients with CF may be beneficial, subsequently lowering morbidity, and increasing survival.


Asunto(s)
Fibrosis Quística/complicaciones , Ileus/complicaciones , Meconio , Adolescente , Adulto , Factores de Edad , Índice de Masa Corporal , Niño , Fibrosis Quística/mortalidad , Fibrosis Quística/terapia , Diatrizoato de Meglumina/uso terapéutico , Progresión de la Enfermedad , Enema , Femenino , Humanos , Ileus/terapia , Lactante , Israel , Pulmón , Masculino , Pruebas de Función Respiratoria , Estudios Retrospectivos , Factores de Riesgo , Análisis de Supervivencia , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA