Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Heart Vessels ; 37(12): 1995-2001, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35794489

RESUMEN

OBJECTIVES: The purpose of this study is to investigate the early and late outcomes of axillary intra-aortic balloon pump (IABP) implantation as a bridge to heart transplantation, comparing the grafted technique with the percutaneous technique. METHODS: Between July 2009 and January 2020, 163 patients underwent an axillary IABP insertion as a bridge to heart transplantation. Among them, 97 patients underwent axillary IABP implantation through a graft sutured onto the axillary artery (Group A) and 66 patients underwent percutaneously (Group B). Propensity matching identified 53 matched pairs for analysis (C-statistics 0.741). The primary outcomes of interest included IABP-related complications, success rate of a bridge to transplantation, in-hospital mortality, and late survival. RESULTS: In the propensity-score matched cohort, there were no significant differences in the baseline characteristics between the two groups. The operation time was significantly longer in Group A than in Group B (141.5 ± 38.3 min vs 42.7 ± 19.3 min, p < 0.01). The complication rates including stroke, re-exploration for bleeding, and aortic event were not significantly different between Group A and B. However, Group A required more transfusion and re-exploration for bleeding. The success rate of a bridge to transplantation was similar between Group A (47/53, 88.7%) and Group B (47/53, 88.7%). There were no significant differences in in-hospital mortality and late survival between two groups. CONCLUSION: In the propensity score matching analysis, there were not any significant differences between the two groups in IABP-related complications, in-hospital mortality, and late survival. The percutaneous technique provided a shorter operation time and less requirement of transfusion and re-exploration for bleeding compared to the grafted technique. The percutaneous technique might be favorable when feasible.


Asunto(s)
Trasplante de Corazón , Corazón Auxiliar , Humanos , Puntaje de Propensión , Estudios Retrospectivos , Contrapulsador Intraaórtico/efectos adversos , Resultado del Tratamiento
2.
Heart Vessels ; 37(4): 647-653, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34585275

RESUMEN

We sought to assess the impact of the aortic root geometry on developing de novo aortic insufficiency (AI) in patients undergoing left ventricular assist device (LVAD). In total, 114 patients underwent LVAD implantation between February 2016 and January 2020 were included in this study (HeartMate3 N = 68, HeartWare N = 46). Significant aortic insufficiency was defined as mild-to-moderate or greater in echocardiography. The cohort was divided into two groups; those who developed significant AI (Group AI: n = 13) and did not (Group non-AI: n = 101). The primary outcomes of interest included late survival and predictors for significant AI. The patients in Group AI were older than Group non-AI (62.6 ± 11.9 vs 51.3 ± 14.0 years, p < 0.01). The diameter of proximal ascending aorta in Group AI was larger than Group non-AI (31.0 ± 5.0 vs 27.4 ± 4.3 mm, p < 0.01). Aortic valve remained closed in 53.8% in Group AI and 36.6% in Group non-AI (p = 0.24). The late survival was not significantly different between the groups (67.1% vs 76.0% at 3 years, log rank = 0.97). The Cox hazard model showed that larger proximal ascending aortic diameter/BSA (HR 1.55, CI 1.19-2.04, p < 0.01) and not-opening aortic valve (HR 4.73, CI 1.43-16.9, p = 0.01) were independent risk factors for significant AI. The cutoff value of proximal ascending aortic diameter/BSA was 15.5 (area under curve: 0.770, sensitivity: 0.69, specificity: 0.79). Dilated proximal ascending aorta at the time of LVAD surgery and not-opening aortic valve during follow-up were associated with the incidence of de novo significant AI.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Corazón Auxiliar , Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/etiología , Corazón Auxiliar/efectos adversos , Humanos , Incidencia , Estudios Retrospectivos , Función Ventricular Izquierda
3.
Ann Vasc Surg ; 83: 42-52, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34995740

RESUMEN

OBJECTIVE: Axillary Intra-aortic balloon pump (IABP) has been increasingly utilized for hemodynamic support in heart failure patients. Vascular complications associated with axillary IABP such as dissection or rupture are relatively rare but not negligible that could negatively affect clinical outcomes. We summarized our experiences. METHODS: This is a retrospective study reviewing of all patients receiving an axillary IABP between June 2016 and November 2020. A total of 199 patients underwent percutaneous axillary IABP placement. 6 patients (6/199, 3.0%) were complicated with arterial/aortic dissection or rupture during the procedures or the course of treatment. We described their clinical presentations and outcomes. RESULTS: Vascular complications included acute type A aortic dissection in 2 patients, descending aortic rupture in 1 patient, abdominal aortic rupture along with type B aortic dissection in 1 patient, and the localized left subclavian artery dissection in 2 patient. 2 type A aortic dissection cases were surgically treated: 1 with emergent left ventricle assist device and ascending aorta replacement, the other with emergent left ventricle assist device. Emergent endovascular treatment was successfully performed in 2 aortic rupture cases. The left subclavian artery dissection cases were managed medically. The postoperative/treatment course was uneventful in all patients. CONCLUSION: Percutaneous axillary IABP therapy can cause significant vascular complications. Early diagnosis and prompt treatment would be the key to improve the clinical outcomesv.


Asunto(s)
Disección Aórtica , Rotura de la Aorta , Corazón Auxiliar , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/etiología , Rotura de la Aorta/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
4.
Heart Surg Forum ; 25(1): E152-E154, 2022 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-35238299

RESUMEN

We present two cases of successful surgical correction of a HeartMate 3 left ventricular assist device (LVAD) outflow graft twisting through a subcostal approach. These twistings were diagnosed with computed tomography or pull-back pressure measurement. Technically, a subcostal approach allowed us to access directly the twisted outflow graft and the device connector in a less invasive fashion as compared with a re-sternotomy. Diagnostic modality and surgical tips that address graft twisting are presented within the discussion of these two case studies. The institutional review board of our institution approved this study and waived the requirement for informed consent.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/cirugía , Humanos , Complicaciones Posoperatorias , Estudios Retrospectivos , Esternotomía/métodos
5.
Int Heart J ; 63(1): 56-61, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35095077

RESUMEN

Optimal heart rate (HR) is a promising therapeutic target in patients with heart failure with reduced ejection fraction. Nevertheless, the implication of optimal HR in patients with left ventricular assist devices (LVAD) remains unknown. The cohort included consecutive patients with sinus rhythm undergoing LVAD implantation between 2014 and 2018. Ideal HR was calculated as follows: 93 - 0.13 × (deceleration time [msec]). The impact of "HR difference," defined as an HR difference between the actual HR at discharge and the calculated ideal HR, on the 1-year mortality and heart failure readmissions was investigated. A total of 143 patients (55 years old, 101 men) was identified and tertiled considering their HR differences: (1) the optimal HR group (n = 49; HR difference < 27 bpm), (2) the suboptimal HR group (n = 47; HR difference = 27-42 bpm), and (3) the nonoptimal HR group; HR difference (n = 47; HR difference > 43 bpm). The nonoptimal HR group had a significantly higher 1-year cumulative incidence of the primary endpoint compared with the optimal HR group (38% versus 16%, P = 0.029) with a hazard ratio of 1.69 (95% confidence interval 1.02-2.57) adjusted for 6 potential confounders. In conclusion, nonoptimized HR negatively affected clinical outcomes in LVAD patients. The implication of deceleration time-guided HR optimization in LVAD patients should be further investigated.


Asunto(s)
Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Frecuencia Cardíaca/fisiología , Corazón Auxiliar , Adulto , Anciano , Estudios de Cohortes , Femenino , Insuficiencia Cardíaca/mortalidad , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Prueba de Estudio Conceptual , Volumen Sistólico/fisiología , Tasa de Supervivencia , Resultado del Tratamiento
6.
Perfusion ; 36(5): 463-469, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32909513

RESUMEN

BACKGROUND: Recently, del Nido cardioplegia solution (DN) has been utilized in adult cardiac surgery. However, adequate interval of maintenance dose(s) is still unclear. The purpose of this study was to assess the safety and efficacy of our DN protocol by comparing with conventional cold whole blood cardioplegia (CWB). METHODS: A total of 1003 consecutive patients (DN group, N = 350 vs. CWB group, N = 653) underwent cardiovascular surgery between July 2013 and September 2018 were included in this study. The DN protocol was to administer 1000 to 1200 ml as an initial dose and to add maintenance dose(s) (500 ml each) every 60 minutes when the estimated cross-clamp time was over 90 minutes. CWB was given every 20 minutes, regardless of cross-clamp time. Propensity matching identified 254 matched pairs for analysis. The preoperative and postoperative data were reviewed. RESULTS: Cross-clamp time was significantly shorter in the DN group compared with the CWB group (107 ± 56 minutes vs. 116 ± 49 minutes, p = 0.0458). A retrograde cannula was used in 124 (48.8%) patients in the DN group and 181 (71.3%) patients in the CWB group (p < 0.0001). There were no significant differences in requiring postoperative cardiac supports (inotropes, mechanical circulatory supports) and major complications. In-hospital mortality was similar between two groups (DN group: 3.2% vs. CWB group: 2.4%, p = 0.5872). CONCLUSIONS: Short-term clinical outcomes in the patients underwent cardiovascular surgery with the DN protocol including the redosing interval strategy were acceptable. Also, DN protocol was associated with shortened cross-clamp time and less usage of the retrograde cannula.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Soluciones Cardiopléjicas , Adulto , Soluciones Cardiopléjicas/uso terapéutico , Paro Cardíaco Inducido , Humanos , Periodo Posoperatorio , Estudios Retrospectivos
7.
J Card Surg ; 35(9): 2410-2413, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32652620

RESUMEN

We report the successful endovascular repair of a rare case of aortic rupture caused by axillary intra-aortic balloon pump (IABP) insertion failure. A 38-year-old Jehovah's Witness female with situs inversus totalis was referred to our hospital for acute decompensated heart failure. We placed an axillary IABP for circulatory support. However, an exchange was required due to balloon malfunction (kinked driveline). Unfortunately, the exchange was complicated by an iatrogenic aortic rupture along with a large hematoma compressing the trachea. Emergent endovascular repair was performed successfully without any blood transfusion. Postoperative computed tomography showed a successfully repaired aorta and resolving hematoma.


Asunto(s)
Rotura de la Aorta , Procedimientos Endovasculares , Testigos de Jehová , Situs Inversus , Adulto , Aorta/cirugía , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/cirugía , Femenino , Humanos , Situs Inversus/complicaciones
8.
Mol Biol Evol ; 35(12): 2928-2939, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-30252081

RESUMEN

Pheromones are crucial for eliciting social and sexual behaviors in diverse animal species. The vomeronasal receptor type-1 (V1R) genes, encoding members of a pheromone receptor family, are highly variable in number and repertoire among mammals due to extensive gene gain and loss. Here, we report a novel pheromone receptor gene belonging to the V1R family, named ancient V1R (ancV1R), which is shared among most Osteichthyes (bony vertebrates) from the basal lineage of ray-finned fishes to mammals. Phylogenetic and syntenic analyses of ancV1R using 115 vertebrate genomes revealed that it represents an orthologous gene conserved for >400 My of vertebrate evolution. Interestingly, the loss of ancV1R in some tetrapods is coincident with the degeneration of the vomeronasal organ in higher primates, cetaceans, and some reptiles including birds and crocodilians. In addition, ancV1R is expressed in most mature vomeronasal sensory neurons in contrast with canonical V1Rs, which are sparsely expressed in a manner that is consistent with the "one neuron-one receptor" rule. Our results imply that a previously undescribed V1R gene inherited from an ancient Silurian ancestor may have played an important functional role in the evolution of vertebrate vomeronasal organ.


Asunto(s)
Evolución Biológica , Receptores de Feromonas/genética , Células Receptoras Sensoriales/metabolismo , Vertebrados/genética , Órgano Vomeronasal/metabolismo , Animales , Humanos , Receptores de Feromonas/metabolismo , Selección Genética , Homología de Secuencia , Vertebrados/metabolismo
9.
Echocardiography ; 35(5): 753-754, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29600571

RESUMEN

Fibrous strand rupture is a rare cause of acute aortic regurgitation, but is a serious condition because of acute massive regurgitation. Therefore, prompt and accurate diagnosis is required. We saw a 53-year-old man who presented with acute dyspnea without evidence of infection. Transesophageal echocardiography revealed severe aortic regurgitation because of fibrous strand rupture. We performed surgery and found that the fibrous strand of the right coronary leaflet was ruptured. In cases of acute aortic regurgitation, the rupture of fibrous strand should be considered and transesophageal echocardiography would be very useful to diagnose it.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Enfermedad Aguda , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Fibrosis/complicaciones , Fibrosis/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Rotura Espontánea/complicaciones , Rotura Espontánea/diagnóstico
10.
Circ J ; 81(5): 689-693, 2017 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-28179595

RESUMEN

BACKGROUND: We evaluated the outcomes of totally endoscopic minimally invasive surgery for atrial septal defect (ASD) using a glutaraldehyde-treated autologous pericardial patch in the transcatheter interventional era.Methods and Results:We retrospectively reviewed 37 consecutive patients who underwent totally endoscopic ASD closure with a glutaraldehyde-treated autologous pericardial patch between June 2011 and April 2015. All patients had been deferred from catheter-based intervention for clinical or anatomical reasons. We analyzed operative outcomes and postoperative echocardiographic data. The mean age was 45.7±16.5 years, and 25 patients (67.6%) were women. The mean ratio of pulmonary to systemic flow was 2.4±0.7. Six patients (16.2%) underwent concomitant tricuspid valve repair, and 3 patients (8.1%) underwent concomitant atrial fibrillation surgery. There were no operative deaths, and the median length of hospital stay was 5 days. Postoperative echocardiography revealed trivial residual shunt in 1 patient. During the follow-up period, there were no re-interventions for ASD or readmission for heart failure. Follow-up echocardiography revealed no recurrent shunt or calcification of the autologous pericardial patch. CONCLUSIONS: Totally endoscopic ASD closure with a glutaraldehyde-treated autologous pericardial patch demonstrated excellent outcomes. It is a useful option for patients with unfavorable anatomy or other reasons excluding transcatheter intervention.


Asunto(s)
Endoscopía/métodos , Glutaral/uso terapéutico , Defectos del Tabique Interatrial/cirugía , Pericardio/trasplante , Adulto , Autoinjertos , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Estudios Retrospectivos , Trasplante de Tejidos/métodos , Resultado del Tratamiento
11.
Heart Surg Forum ; 19(6): E306-E307, 2016 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-28054904

RESUMEN

Here we report the early outcome of mitral valve replacement using a newly designed stentless mitral valve for failure of initial mitral valve repair. Mitral valve plasty (MVP) for mitral regurgitation is currently a standard technique performed worldwide. However, whether mitral valve repair should be performed for patients with advanced leaflet damage or complicated pathology remains controversial. Mitral valve replacement might be feasible for patients who have undergone failed initial MVP; however, it is not an optimal treatment because of poor valve durability and the need for anticoagulative therapy. We report two cases of successful mitral valve replacement using a newly designed stentless mitral valve made of fresh autologous pericardium, which may have a potential benefit over mitral valve repair or mitral valve replacement with a mechanical or bioprosthetic valve.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Pericardio/trasplante , Ecocardiografía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico , Diseño de Prótesis , Reoperación , Factores de Tiempo
12.
Kyobu Geka ; 69(4): 299-303, 2016 Apr.
Artículo en Japonés | MEDLINE | ID: mdl-27210258

RESUMEN

BACKGROUND: This study elucidated incidence and risk factors of permanent neurological deficit( PND) after surgical repair of the acute type A aortic dissection. METHODS AND RESULTS: 669 patients who underwent emergent ascending/hemiarch replacement( AAR/HAR) and total arch replacement (TAR) were analyzed. AAR/HAR was performed in 441(65.9%) and TAR in 228 (34.1%). PND occurred in 58 patients(8.7%). Incidence of PND in AAR/HAR and TAR were 8.4% and 9.2% respectively(p=0.772). Logistic regression analysis showed preoperative conscious disturbance, preoperative paralysis, preoperative myocardial ischemia, and longer operation time associated postoperative PND. CONCLUSIONS: Rapid initiation of surgery after diagnosis and shorten operation time are advisable to improve outcomes. Preoperative neurological deficit and myocardial ischemia are risk factor of postoperative PND. Incidence of PND in AAR/HAR and TAR was equivalent.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Enfermedades del Sistema Nervioso/etiología , Anciano , Aorta Torácica/cirugía , Femenino , Humanos , Masculino , Tempo Operativo , Complicaciones Posoperatorias
13.
J Card Surg ; 29(1): 22-5, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24251776

RESUMEN

The Medtronic freestyle aortic root bioprosthesis (Medtronic, Inc., Minneapolis, MN, USA) is a stentless valve with an effective orifice area that is larger than that observed on other bioprostheses. However, there have been sporadic reports of structural valve deterioration (SVD), such as aortic root wall rupture, leaflet tearing, and pseudoaneurysm formation. We report five cases of SVD of freestyle aortic root bioprostheses.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Resultado del Tratamiento
14.
Am J Cardiol ; 221: 77-83, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38636625

RESUMEN

The impact of inconsistent enhancement within the patent false lumen on the occurrence of late aortic events remains uncertain. We enrolled 55patients who exhibited a patent false lumen after hemiarch replacement. The Hounsfield unit (HU) measurements in the patent false lumen were obtained at 2 specific locations: the aortic arch (a) and the descending aorta (b). The false lumen HU score was calculated as the absolute value of 1 - a/b, representing the discrepancy in HUs within the patent false lumen. We investigated the cut-off value of the false lumen HU score with the receiver operating characteristics curve to predict the incidence of late aortic events. We divided the patients based on the cut-off value and compared the cumulative incidence of the late aortic events. The analysis of the receiver operating characteristics curve showed that the cut-off value of the false lumen HU score was 0.345. Based on this cut-off value, we divided them into 2 groups: Group A (score <0.345, n = 26) and Group B (score ≥0.345, n = 29). The baseline characteristics were similar between the 2 groups. The cumulative incidence of the late aortic events was significantly lower in Group A (7.8% at 5 years) than in Group B (39.9% at 5 years) (p = 0.02). The false lumen HU score might be useful to predict the incidence of late aortic events after hemiarch replacement.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Complicaciones Posoperatorias , Humanos , Disección Aórtica/cirugía , Femenino , Masculino , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Angiografía por Tomografía Computarizada/métodos , Curva ROC , Incidencia , Enfermedad Aguda
16.
Artículo en Inglés | MEDLINE | ID: mdl-37421402

RESUMEN

OBJECTIVES: It remains unknown if the left atrial appendage closure (LAAC) at the time of left ventricular assist device (LVAD) surgery can reduce ischaemic cerebrovascular accidents. METHODS: Consecutive 310 patients who underwent LVAD surgery with HeartMate II or 3 between January 2012 and November 2021 were included in this study. The cohort was divided into 2 groups: patients with LAAC (group A) and without LAAC (group B). We compared the clinical outcomes including the incidence of cerebrovascular accident between 2 groups. RESULTS: Ninety-eight patients were included in group A, and 212 patients in group B. There were no significant differences between 2 groups in age, preoperative CHADS2 score and history of atrial fibrillation. In-hospital mortality did not differ significantly between the 2 groups (group A: 7.1%, group B: 12.3%, P = 0.16). Thirty-seven patients (11.9%) experienced ischaemic cerebrovascular accident (5 patients in group A and 32 patients in group B). The cumulative incidence from ischaemic cerebrovascular accidents in group A (5.3% at 12 months and 5.3% at 36 months) was significantly lower than that in group B (8.2% at 12 months and 16.8% at 36 months; P = 0.017). In a multivariable competing risk analysis, LAAC was associated with reducing ischaemic cerebrovascular accidents (hazard ratio 0.38, 95% confidence interval 0.15-0.97, P = 0.043). CONCLUSIONS: Concomitant LAAC in LVAD surgery can reduce ischaemic cerebrovascular accidents without increasing perioperative mortality and complications.

17.
J Cardiothorac Surg ; 18(1): 288, 2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37828522

RESUMEN

BACKGROUND: Tricuspid regurgitation(TR) following heart transplantation could adversely affect clinical outcomes. In an effort to reduce the incidence of TR, prophylactic donor heart tricuspid valve annuloplasty has been performed during heart transplantation in our institution. We assessed early and long-term outcomes. METHODS: Between August 2011 and August 2021, 349 patients who underwent prophylactic tricuspid valve annuloplasty were included. Tricuspid valve annuloplasty was performed using the DeVega annuloplasty technique. The clinical outcomes of the interests included complete atrioventricular block requiring pacemaker implantation, the occurrence of significant TR(defined as moderate or greater), and survival. Long-term survival was compared in patients with and without significant TR using the Kaplan-Meier method. The Cox proportional hazards regression with time-dependent covariate analysis was used to see if significant TR affected the long-term survival. RESULTS: There was one patient(0.3%) who required pacemaker implantation for complete atrioventricular block. No patients developed tricuspid valve stenosis that required intervention. Significant TR developed in 31 patients(8.9%) during the follow-up period. The survival rate of patients who developed significant TR was significantly lower than that of those who did not(log rank < 0.01). Significant TR was associated with the long-term mortality(HR2.92, 95%CI 1.47-5.82, p < 0.01). CONCLUSIONS: Prophylactic donor heart tricuspid valve annuloplasty has the potential to reduce the occurrence of significant TR and can be performed safely. The significant TR that developed in patients with prophylactic annuloplasty negatively affected survival and was an independent predictor of long-term mortality.


Asunto(s)
Bloqueo Atrioventricular , Anuloplastia de la Válvula Cardíaca , Trasplante de Corazón , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Válvula Tricúspide/cirugía , Trasplante de Corazón/efectos adversos , Estudios Retrospectivos , Donantes de Tejidos , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Anuloplastia de la Válvula Cardíaca/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento
18.
J Nutr Biochem ; 108: 109093, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35724814

RESUMEN

Lignans are plant-derived compounds that act as partial estrogen agonists. Chondroitin sulfate proteoglycans (CSPGs) represent one of the major components of the extracellular matrix. Here we aimed to understand the role of sesamin (SES), a major lignan compound, in the biosynthesis and degradation of CSPGs in the mouse hippocampus because CSPGs play a key role in the regulation of cognitive functions through the promotion of adult neurogenesis. The expression of the pro-inflammatory cytokine interleukin-1ß was decreased by SES administration in the hippocampus of lipopolysaccharide (LPS)-treated mice, a model of neuroinflammation-induced cognitive deficits. The expression of genes related to biosynthesis and degradation of CSPGs in the hippocampus of LPS-treated mice was both increased and decreased by SES administration. Further, the diffuse extracellular matrix labeling of CSPGs by Wisteria floribunda agglutinin (WFA) in the hippocampus of LPS-treated mice was increased by SES administration. The densities of neural stem cells, late transit-amplifying cells, and newborn-granule cells in the hippocampus of LPS-treated mice were also increased by SES administration. Moreover, SES-induced alterations in gene expression, WFA labeling, and adult neurogenesis in LPS-treated mice were more evident in the dorsal hippocampus (center of cognition) than in the ventral hippocampus (center of emotion). Neither LPS nor SES administration affected locomotor activity, anxiety-like behavior, and depression-related behavior. However, impairments in contextual memory and sensorimotor gating in LPS-treated mice were recovered by SES administration. Our results show that SES can promote adult hippocampal neurogenesis through the upregulation of CSPGs, which may alleviate cognitive deficits induced by neuroinflammation.


Asunto(s)
Sulfatos de Condroitina , Lignanos , Animales , Proteoglicanos Tipo Condroitín Sulfato , Cognición , Dioxoles , Modelos Animales de Enfermedad , Hipocampo , Lignanos/farmacología , Lignanos/uso terapéutico , Lipopolisacáridos/toxicidad , Ratones , Ratones Endogámicos C57BL , Enfermedades Neuroinflamatorias , Regulación hacia Arriba
19.
J Cardiol ; 79(5): 611-617, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34895789

RESUMEN

BACKGROUND: The axillary intra-aortic balloon pump has an advantage over the femoral intra-aortic balloon pump in terms of mobility. While axillary intra-aortic balloon pump has been widely used recently as a mode of mechanical circulatory support, the number of reported cases is limited. The purpose of this study is to summarize our experience and to evaluate the safety and efficacy of axillary intra-aortic balloon pump support. METHODS: Between July 2009 and July 2019, 241 patients underwent axillary intra-aortic balloon pump support for heart failure. The intended therapeutic goals were bridge to heart transplantation (n=146), left ventricular assist device (n=66), and recovery (n=29). Intra-aortic balloon pumps were inserted through a graft sutured onto the axillary artery in 142 patients (58.9%) and percutaneously in 99 patients (41.1%). It was placed from the right axillary artery in 147 patients (61.0%) and left in 94 patients (39.0%). Primary outcome measures of interest included achievement of intended therapeutic goal, hemodynamic data, ambulatory data, intra-aortic balloon pump-related death, and complications. RESULTS: Ambulation was possible in 217 patients (90.0%) during support. Hemodynamic parameters improved significantly after axillary intra-aortic balloon pump support. In total, 13 patients (5.4%) died and 10 patients (4.1%) required escalation of mechanical support. There were no deaths directly attributable to intra-aortic balloon pumps. Intra-aortic balloon pump-related stroke occurred in 6 patients (2.5%). Overall, 86.7% were successfully bridged to intended therapy (transplantation 90.4%, left ventricular assist device 90.9%, and recovery 58.6%). CONCLUSIONS: Axillary intra-aortic balloon pumps allow most patients to ambulate during support, improve hemodynamics, and lead to the intended goals successfully.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Contrapulsador Intraaórtico/efectos adversos , Estudios Retrospectivos
20.
ESC Heart Fail ; 9(4): 2484-2490, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35460200

RESUMEN

AIMS: Heart transplantation involves many factors such as donor selection, recipient management, multidisciplinary assessment, coordination with other organ teams, and transportation. Because of some unpredictable factors, heart transplantation can be conducted at any time of day. The purpose of this study is to investigate if outcomes differ between heart transplants taking place inside or outside of normal working hours. METHODS AND RESULTS: We reviewed patients who underwent heart transplantation at our institution from January 2010 to July 2020 (n = 329). Based on the documented start time of the recipient surgeries, the cohort was divided into two groups: working hours (Group A: 7:30 to 17:00; n = 92) and after hours (Group B: 17:00 to 7:30; n = 237). We compared these groups using propensity score matching analysis. After propensity score matching, 78 pairs of patients were successfully matched. We reviewed early and late clinical outcomes including survival. Long-term survival was compared using the Kaplan-Meier method. In the propensity-score matched patients, there were no significant differences in the baseline characteristics between two groups. In-hospital mortality was not significantly different between the two groups (Group A: 6.4% vs. Group B: 2.6%, P = 0.44). Ischaemic time and cross-clamp time did not differ between the groups. In terms of postoperative complications, there were no significant differences between two groups in stroke (6.4% vs. 3.9%, P = 0.72), primary graft dysfunction requiring extracorporeal membrane oxygenation (5.1% vs. 7.7%, P = 0.75), re-exploration for bleeding (9.0% vs. 12.8%, P = 0.44), and newly required haemodialysis (7.7% vs. 6.4%, P = 0.75). The survival rate in Group A (88.1% at 1 year, 81.3% at 3 years) was not significantly different from Group B (90.5% at 1 year, 82.3% at 3 years, log rank = 0.96). CONCLUSION: There was no significant difference in clinical outcomes between heart transplants taking place inside or outside of working hours. A high quality of care can be provided for heart transplant patients even during after hours.


Asunto(s)
Trasplante de Corazón , Admisión y Programación de Personal , Estudios de Cohortes , Oxigenación por Membrana Extracorpórea , Trasplante de Corazón/métodos , Humanos , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA