Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Shoulder Elbow Surg ; 33(4): e175-e184, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37652214

RESUMEN

BACKGROUND: To reduce hardware-related complications in coracoid graft fixation to the anterior aspect of the glenoid, a metal-free Latarjet technique was recently introduced. The aim of this study was to compare the primary stability of a classic Latarjet procedure with 2 metal screws to a novel metal-free, all-suture cerclage method. It is hypothesized that fixation of the coracoid graft with 2 malleolar screws will provide higher primary stability compared with an all-suture cerclage technique. METHODS: This biomechanical in vitro study was conducted on 12 fresh-frozen cadaveric shoulders (6 matched pairs) with a mean donor age of 80 years (range, 67-89 years). Coracoid graft fixation was performed using a recently introduced all-suture cerclage technique (group A) or a classic Latarjet technique with two 4.5-mm malleolar screws (group B). The conjoint tendon was loaded with a static force of 10 N to simulate the sling effect. Graft loading with a probe head consisted of 6 ascending load levels (10-50 N, 10-100 N, 10-150 N, 10-200 N, 10-250 N, and 10-300 N) with 100 cycles each at 1 Hz. Relative motion of the bone graft to the glenoid was measured using an optic 3-dimensional system. RESULTS: While loading the conjoint tendon with 10 N, no difference in mean displacement of the bone-graft was found between both groups (P = .144). During cyclic loading, a significant difference in relative displacement for both groups was already detected in load level 1 (group A: 2398.8 µm vs. group B: 125.7 µm; P = .024), and this trend continued with the following load levels (P < .05). DISCUSSION AND CONCLUSION: The study demonstrated that the innovative metal-free, all-suture cerclage fixation technique results in higher micromotion than the classic coracoid graft fixation with 2 malleolar screws. According to the present biomechanical investigation, shoulders treated with a metal-free all-suture cerclage technique might need adapted rehabilitation protocols to protect the construct and allow for graft healing.


Asunto(s)
Bursitis , Inestabilidad de la Articulación , Luxación del Hombro , Articulación del Hombro , Humanos , Anciano , Anciano de 80 o más Años , Articulación del Hombro/cirugía , Trasplante Óseo , Escápula/cirugía , Luxación del Hombro/cirugía , Suturas , Fenómenos Biomecánicos , Inestabilidad de la Articulación/cirugía
2.
Arch Orthop Trauma Surg ; 143(8): 4853-4860, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36795151

RESUMEN

INTRODUCTION: One current trend in the field of shoulder arthroplasty is a design shift to shorter and metaphyseal fixed humeral stem components. The aim of this investigation is to analyze complications resulting in revision surgery after anatomic (ASA) and reverse (RSA) short stem arthroplasty. We hypothesize that complications are influenced by the type of prosthesis and indication for arthroplasty. MATERIALS AND METHODS: A total of 279 short stem shoulder prostheses were implanted by the same surgeon (162 ASA; 117 RSA), and 223 of these prostheses were implanted as primary procedures; in 54 cases, arthroplasty was performed secondary to prior open surgery. Main indications were osteoarthritis (OA) (n = 134), cuff tear arthropathy (CTA) (n = 74) and posttraumatic deformities (PTr) (n = 59). Patients were evaluated at 6 weeks (follow-up 1; FU1), 2 years (FU2) and the time span of the last follow-up defined as FU3 with a minimum FU of 2 years. Complications were categorized into early complications (within FU1), intermediate complications (within FU2) and late complications (> 2 years; FU3). RESULTS: In total, 268 prostheses (96.1%) were available for FU1; 267 prostheses (95.7%) were available for FU2 and 218 prostheses (77.8%) were available for FU3. The average time for FU3 was 53.0 months (range 24-95). A complication leading to revision occurred in 21 prostheses (7.8%), 6 (3.7%) in the ASA group and 15 (12.7%) in the RSA group (p < 0.005). The most frequent cause for revision was infection (n = 9; 42.9%). After primary implantation, 3 complications (2.2%) occurred in the ASA and 10 complications (11.0%) in the RSA group (p < 0.005). The complication rate was 2.2% in patients with OA, 13.5% in CTA and 11.9% in PTr. CONCLUSIONS: Primary reverse shoulder arthroplasty had a significantly higher rate of complications and revisions than primary and secondary anatomic shoulder arthroplasty, respectively. Therefore, indications for reverse shoulder arthroplasty should be critically questioned in each individual case.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteoartritis , Articulación del Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Prótesis de Hombro/efectos adversos , Osteoartritis/cirugía , Osteoartritis/etiología , Húmero/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Reoperación , Rango del Movimiento Articular
3.
J Orthop ; 51: 130-136, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38384727

RESUMEN

Purpose: As capsule elongation is assumed to weaken the static stability of the shoulder joint, the purpose of this biomechanical study was to demonstrate that capsule elongation occurs immediately after a first-time shoulder dislocation and not just after recurrent dislocation events. We hypothesize an increment in joint clearance due to joint capsule elongation after a first-time dislocation. Methods: An experimental in-vitro study was conducted on 6 paired fresh frozen human shoulders (4 females; 2 males; 12 specimen) with a mean age of 80 (Range 67-89) years. The shoulder joint with the articular capsule was exposed and an inferior static tension force of 2.5 N was applied to the humerus prior to dislocation. Next, the humeral head was dislocated and was then immediately reduced back into the start position. The joint gap as well as joint capsule deformation was assessed using optical techniques. Results: The radiographic joint gap increased from 13.7 ± 6.9 mm (prior to dislocation) to 18.1 ± 6.5 mm (post dislocation) (p < .001). The increase in joint clearance was 4.4 mm. The joint capsule elongated from 5.9 ± 0.005 % (prior to dislocation) to 9.4 ± 0.007 % (post dislocation) (p < .001). The mean increase in joint capsule elongation was 3.5 %. Conclusions: Capsule elongation was observed immediately after a simulated first-time shoulder dislocation in an in-vitro model of elderly human cadavers. It might therefore not only be a phenomenon of recurrent dislocation events.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA