Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Metrologia ; 54(1A)2017.
Artículo en Inglés | MEDLINE | ID: mdl-33100400

RESUMEN

In 2016, comparisons of activity measurements of 18F and 64Cu using the Transfer Instrument of the International Reference System (SIRTI) took place at the National Institute of Standards and Technology (NIST, USA). This is the first SIRTI comparison for 64Cu. Ampoules containing about 27 kBq of 18F and 100 kBq of 64Cu solutions were measured in the SIRTI for about 5 and 1.5 half-lives, respectively. The NIST standardized the activity in the ampoules by ionization chamber measurements traceable to 4π(LS)ß-γ anticoincidence measurements. The comparisons, identifiers BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64, are linked to the corresponding BIPM.RI(II)-K1.F-18 and BIPM.RI(II)-K1.Cu-64 comparisons and degrees of equivalence with the respective key comparison reference values have been evaluated. The NIST replaces its earlier degree of equivalence for 18F obtained in the frame of the CCRI(II)-K3.F-18 comparison in 2001.

2.
Br Poult Sci ; 54(5): 603-10, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24053546

RESUMEN

1. Because the components of the egg differ in nutrient content, and the proportions of these components change over time, the daily intake of nutrients required to produce an egg will also change with time. Information on these relationships is essential when attempting to determine the nutrient requirements of a broiler breeder hen at different stages of lay, and in predicting performance when the hen is supplied with a given amount of food with a given nutrient composition. 2. Yolk weight is related to hen age and may be predicted using a linear-by-linear function, the coefficients of which are the same for Cobb and Ross breeders. Allometric functions may be used to predict albumen weight from yolk weight, and shell weight from the weight of the egg contents. Egg weight is given by the sum of the three components. 3. The proportion of yolk increased with advancing age whilst the proportions of albumen and shell decreased. However, at a given age, larger eggs contain proportionally more albumen. Eggs from Cobb hens had proportionately more albumen than Ross eggs towards the end of lay. 4. A stochastic population model verified that these functions accurately reflect the proportional changes in the egg components with advancing hen age and at a given age, over a range of egg weights.


Asunto(s)
Pollos/fisiología , Cáscara de Huevo/química , Clara de Huevo/química , Yema de Huevo/química , Modelos Teóricos , Oviposición/fisiología , Animales , Simulación por Computador , Ingestión de Alimentos/fisiología , Femenino , Procesos Estocásticos
3.
Appl Radiat Isot ; 154: 108834, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31536910

RESUMEN

In the summer of 2017, the Système International de Référence Transfer Instrument (SIRTI) of the Bureau International des Poids et Mesures (BIPM) was hosted by the National Research Council of Canada (NRC) in Ottawa, Canada. This SIRTI visit was unique in many aspects. It was the first visit of the SIRTI to Canada. NRC was the first National Metrological Institute (NMI) to perform comparisons of four isotopes (99mTc, 18F, 64Cu and 11C) during a single two-week period. Finally, this was the first official measurement of 11C in the SIRTI. The NRC had performed a primary standardization of 11C in February of 2017 and calibrated its Secondary Standard Ionizing Radiation Chamber System (SSIRCS) in preparation for the SIRTI comparison. Two primary Liquid Scintillation methods (CIEMAT/NIST and TDCR) were employed and the results agreed. The stock material was received from a local cyclotron in the form of a 11C-labelled sodium acetate (NaC2H3O2). Three ampoules were prepared for the purposes of comparison; one concentrated from the bulk material and two derived from a single dilution. Some inconsistency was evident due to a weighing problem for one of the ampoules containing the diluted solution, whose measurements were excluded from the analysis. The other two ampoules' results were consistent within their respective uncertainties. The SIRTI was very stable and the final BIPM report will detail the stability checks, performance and behaviour of the SIRTI during its measurement campaign in Canada. There is still no Key Comparison Reference Value (KCRV) for 11C as NRC is the first participant. However, during a test of the SIRTI at NPL in 2014, an equivalent SIRTI activity was measured as 9.87(5) kBq which was consistent with MonteCarlo predictions for 11C in the SIRTI of 9.867(15) kBq. The NRC SIRTI equivalent activity for 11C agrees within uncertainty with these results. This offers encouragement to other NMIs to request a 11C comparison given the consistency of experimental results from NRC and test results from the National Physical Laboratory, UK (NPL) and the BIPM. Finally a half-life measurement was determined from the NRC measurement of multiple half-lives of a 11C ampoule and was found to be 20.332(40)min. From the SIRTI measurements at NRC, the half-life was derived as 20.328(13) min. This is smaller but consistent with the DDEP recommended value of 20.361(23)min.

4.
Appl Radiat Isot ; 109: 17-23, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26682894

RESUMEN

In 2014, the first three comparisons of activity measurements of (18)F were carried out at the VNIIM, NPL and the ENEA-INMRI using the BIPM's Transfer Instrument of the International Reference System. The transfer instrument and the NMIs primary measurement methods are briefly described. The degrees of equivalence with the key comparison reference value defined in the frame of the corresponding SIR comparison have been evaluated. World-wide consistency of activity measurements of (18)F is demonstrated.


Asunto(s)
Radioisótopos de Flúor/análisis , Radioisótopos de Flúor/normas , Laboratorios/normas , Medicina Nuclear/normas , Radiometría/normas , Internacionalidad , Dosis de Radiación , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA