1.
Anal Chem ; 87(6): 3115-22, 2015 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-25708099

RESUMEN

Miniaturized mass spectrometers are becoming increasingly capable, enabling the development of many novel field and laboratory applications. However, to date, triple quadrupole tandem mass spectrometers, the workhorses of quantitative analysis, have not been significantly reduced in size. Here, the basis of a field-deployable triple quadrupole is described. The key development is a highly miniaturized ion optical assembly in which a sequence of six microengineered components is employed to generate ions at atmospheric pressure, provide a vacuum interface, effect ion guiding, and perform fragmentation and mass analysis. Despite its small dimensions, the collision cell efficiently fragments precursor ions and yields product ion spectra that are very similar to those recorded using conventional instruments. The miniature triple quadrupole has been used to detect thiabendazole, a common pesticide, in apples at a level of 10 ng/g.

2.
Anal Chim Acta ; 1276: 341589, 2023 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-37573093

RESUMEN

Routine monitoring of inorganic arsenic in groundwater using sensitive, reliable, easy-to-use and affordable analytical methods is integral to identifying sources, and delivering appropriate remediation solutions, to the widespread global issue of arsenic pollution. Voltammetry has many advantages over other analytical techniques, but the low electroactivity of arsenic(V) requires the use of either reducing agents or relatively strong acidic conditions, which both complicate the analytical procedures, and require more complex material handling by skilled operators. Here, we present the voltammetric determination of total inorganic arsenic in conditions of near-neutral pH using a new commercially available 25 µm diameter gold microwire (called the Gold Wirebond), which is described here for the first time. The method is based on the addition of low concentrations of permanganate (10 µM MnO4-) which fulfils two roles: (1) to ensure that all inorganic arsenic is present as arsenate by chemically oxidising arsenite to arsenate and, (2) to provide a source of manganese allowing the sensitive detection of arsenate by anodic stripping voltammetry at a gold electrode. Tests were carried out in synthetic solutions of various pH (ranging from 4.7 to 9) in presence/absence of chloride. The best response was obtained in 0.25 M chloride-containing acetate buffer resulting in analytical parameters (limit of detection of 0.28 µg L-1 for 10 s deposition time, linear range up to 20 µg L-1 and a sensitivity of 63.5 nA ppb-1. s-1) better than those obtained in acidic conditions. We used this new method to measure arsenic concentrations in contrasting groundwaters: the reducing, arsenite-rich groundwaters of India (West Bengal and Bihar regions) and the oxidising, arsenate-rich groundwaters of Mexico (Guanajuato region). Very good agreement was obtained in all groundwaters with arsenic concentrations measured by inductively coupled plasma-mass spectrometry (slope = +1.029, R2 = 0.99). The voltammetric method is sensitive, faster than other voltammetric techniques for detection of arsenic (typically 10 min per sample including triplicate measurements and 2 standard additions), easier to implement than previous methods (no acidic conditions, no chemical reduction required, reproducible sensor, can be used by non-voltammetric experts) and could enable cheaper groundwater surveying campaigns with in-the-field analysis for quick data reporting, even in remote communities.

3.
Rapid Commun Mass Spectrom ; 25(21): 3281-8, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22006391

RESUMEN

A miniature mass spectrometer capable of detecting analytes eluting from a high-performance liquid chromatography (HPLC) system is described and demonstrated for the first time. The entire instrument, including all pumps and the computer, is contained within a single enclosure that may be conveniently accommodated at the base of the HPLC stack. The microspray ion source, vacuum interface, ion guide, and quadrupole ion filter are all microengineered. These components are fabricated in batches using microelectromechanical systems (MEMS) techniques and considered to be consumables. When coupled to a standard HPLC system using an integrated passive split, the limit of detection for reserpine while scanning the full mass range is 5 ng on-column (1 pg of which is passed to the microspray). The mass range is m/z 100-800, and each spectrum is typically acquired at a rate of 1 scan per second.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas/instrumentación , Sistemas Microelectromecánicos/instrumentación , Miniaturización/instrumentación , Espectrometría de Masas/métodos , Modelos Químicos , Reserpina/análisis , Sensibilidad y Especificidad
4.
J Am Soc Mass Spectrom ; 20(1): 146-56, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18838276

RESUMEN

The limitations of conventional machining and assembly techniques require that designs for quadrupole mass analyzers with rod diameters less than a millimeter are not merely scale versions of larger instruments. We show how silicon planar processing techniques and microelectromechanical systems (MEMS) design concepts can be used to incorporate complex features into the construction of a miniature quadrupole mass filter chip that could not easily be achieved using other microengineering approaches. Three designs for the entrance and exit to the filter consistent with the chosen materials and techniques have been evaluated. The differences between these seemingly similar structures have a significant effect on the performance. Although one of the designs results in severe attenuation of transmission with increasing mass, the other two can be scanned to m/z = 400 without any corruption of the mass spectrum. At m/z = 219, the variation in the transmission of the three designs was found to be approximately four orders of magnitude. A maximum resolution of M/DeltaM = 87 at 10% peak height has been achieved at m/z = 219 with a filter operated at 6 MHz and constructed using rods measuring (508 +/- 5) microm in diameter.