Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Heart Vessels ; 37(1): 99-109, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34374825

RESUMEN

Red cell distribution width (RDW) is reportedly associated with cardiovascular events, including atrial fibrillation (AF). We investigated whether the RDW values were associated with the outcomes of catheter ablation for AF. This retrospective multicenter study included 501 patients with AF (239 paroxysmal AF cases, 196 persistent AF cases, and 66 long-standing persistent AF cases) who underwent initial AF ablation between March 2017 and May 2018. The RDW values were evaluated before and at 1-3 months after the procedure. The patients were stratified based on the recurrence of AF within 1 year after the index procedure with a blanking period of 3 months into recurrence group (107 patients, 21.4%) and no-recurrence group (394 patients, 78.6%). There were no significant differences in preoperative RDW values between the groups (p = 0.37). The RDW value did not change significantly after the ablation in the recurrence group (13.55-13.60%, p = 0.37), although it decreased significantly in the no-recurrence group (13.64-13.37%, p < 0.001). Multivariate Cox proportional hazards regression analyses revealed that a postoperative change in RDW (ΔRDW) was independently associated with AF recurrence (hazard ratio 2.00, 95% confidence interval 1.42-2.76, p < 0.001). Receiver operating characteristic curve analysis revealed that a ΔRDW cut-off value of - 0.1% provided a c-statistic of 0.65 for predicting AF recurrence. Decrease in RDW during the blanking period after ablation independently predicted the 1-year success of AF ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Índices de Eritrocitos , Humanos , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
2.
Circ J ; 85(3): 252-260, 2021 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-33298643

RESUMEN

BACKGROUND: Whether all atrial fibrillation (AF) patients should be evaluated for sleep apnea before catheter ablation (CA) remains controversial. Watch-type peripheral arterial tonometry (W-PAT) is a home sleep testing device and an easier tool for diagnosing sleep apnea than polysomnography. We investigated the prevalence and predictors of sleep apnea using W-PAT in unscreened sleep apnea patients with AF before CA.Methods and Results:The study was conducted under a retrospective, single-center, observational design. We included 776 consecutive patients who underwent both W-PAT and AF ablation. Sleep apnea assessments were successfully performed in 774 patients (99.7%; age 65±11 years, 73.3% male; body mass index [BMI] 24.1±3.5, 56.8% paroxysmal AF). The mean apnea-hypopnea index (AHI) was 20.1±15.6. Although 81.7% of the patients had normal Epworth sleepiness scores (mean 6.5), only 88 (11.4%) had a normal AHI (AHI <5) and 412 (53.2%) had moderate-severe sleep apnea (AHI ≥15). Obesity, male sex, nonparoxysmal AF, hypertension, and a left atrial diameter (LAd) ≥40 mm were predictors of moderate-severe sleep apnea. However, the prevalence of moderate-severe sleep apnea in patients without those predictors (i.e., non-obesity (44.2%), female sex (43.0%), paroxysmal AF (43.9%), no hypertension (45.5%)), and LAd <40 mm (41.0%) was considerably high. CONCLUSIONS: Almost all patients successfully underwent W-PAT to diagnose sleep apnea. Patients undergoing AF ablation had a high prevalence of sleep apnea, and screening for sleep apnea was important in those patients even if they did not have sleepiness or risk factors.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Obesidad , Estudios Retrospectivos , Factores de Riesgo , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/epidemiología , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/epidemiología , Somnolencia
3.
Circ J ; 83(7): 1600-1606, 2019 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-31118365

RESUMEN

BACKGROUND: Little is known about late outcomes after transcatheter aortic valve replacement (TAVR) in dialysis patients.Methods and Results:We enrolled 25 dialysis patients (mean age 76.5 years; mean STS score 14.7%; men 60.0%) with aortic valve stenosis undergoing TAVR at our institute. Cardiovascular mortality and stroke were defined according to the VARC-2 criteria, and major adverse cardiac and cerebrovascular events (MACCE) were investigated. Twenty-three patients (92.0%) were discharged, and the median hospital stay after TAVR was 9 days (IQR, 7.5-11 days). Mortality at 30 days was not observed. The overall survival rate at 1 and 3 years were 80.0% and 55.7%, respectively (follow-up period, 879±493 days; range, 40-1,826 days). At 1 and 3 years, rates of freedom from cardiovascular mortality, disabling stroke, and MACCE were 100% and 83.0%, 91.2% and 84.7%, and 69.8% and 39.9%, respectively. Three patients required redo-TAVR for valve dysfunction at 23, 36, and 38 months after the first TAVR, respectively (The rate of freedom from severe structural valve deterioration at 1 and 3 years was 100% and 85.9%, respectively). CONCLUSIONS: Satisfactory in-hospital outcomes were achieved in dialysis patients after TAVR. Various problems, however, such as complications particular to dialysis patients and valve durability, remained at midterm follow-up. Further studies are recommended to solve these problems, and prudent preoperative assessments should be mandatory.


Asunto(s)
Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Tasa de Supervivencia , Factores de Tiempo
4.
Circ J ; 81(3): 397-404, 2017 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-28123149

RESUMEN

BACKGROUND: Dual antiplatelet therapy (DAPT) is commonly used after transcatheter aortic valve implantation (TAVI); however, the supporting evidence is limited. To determine if aspirin alone is a better alternative to DAPT, we compared the outcomes of patients treated with DAPT or aspirin alone after TAVI.Methods and Results:We analyzed a total of 144 consecutive patients (92 females, mean age 83±6 years) who underwent implantation of a balloon-expandable transcatheter valve (SAPIEN or SAPIEN XT, Edwards Lifesciences). Patients were divided into DAPT (n=66) or aspirin-alone treatment groups (n=78). At 1 year after TAVI, the composite endpoint, which consisted of all-cause death, myocardial infarction, stroke, and major or life-threatening bleeding complications, occurred significantly less frequently (Kaplan-Meier analysis) in the aspirin-alone group (15.4%) than in the DAPT group (30.3%; P=0.031). Valve function assessed by echocardiography was similar between the 2 treatment groups with respect to effective orifice area (1.78±0.43 cm2in DAPT vs. 1.91±0.46 cm2in aspirin-alone group; P=0.13) and transvalvular pressure gradient (11.1±3.5 mmHg in DAPT vs. 10.3±4.1 mmHg in aspirin-alone group; P=0.31). CONCLUSIONS: Treatment with aspirin alone after TAVI had greater safety benefits and was associated with similar valve function as DAPT. These results suggest that treatment with aspirin alone is an acceptable regimen for TAVI patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica/cirugía , Aspirina/administración & dosificación , Bioprótesis , Prótesis Valvulares Cardíacas , Inhibidores de Agregación Plaquetaria/administración & dosificación , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/terapia , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Tasa de Supervivencia
5.
Circ J ; 81(12): 1871-1878, 2017 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-28679970

RESUMEN

BACKGROUND: Advanced left heart failure (HF) often accompanies post-capillary pulmonary hypertension related to RV afterload. Although pulmonary arterial capacitance (PAC), a measure of pulmonary artery compliance, reflects right ventricular (RV) afterload, the clinical utility of PAC obtained by echocardiography (echo-PAC) is not well established in advanced HF.Methods and Results:We performed right heart catheterization in advanced HF patients (n=30), calculating echo-PAC as stroke volume/(tricuspid regurgitation pressure gradient-pulmonary regurgitation pressure gradient). The difference between the echo-PAC and catheter-measured PAC values was insignificant (0.21±0.17 mL/mmHg, P=0.23). Echo-PAC values predicted both pulmonary arterial wedge pressure (PAWP) ≥18 mmHg and pulmonary vascular resistance ≥3 Wood units (P=0.02, area under the curve: 0.88, cutoff value: 1.94 mL/mmHg). Next, we conducted an outcome study with advanced HF patients (n=72). Patients with echo-PAC <1.94 mL/mmHg had more advanced New York Heart Association functional class, higher B-type natriuretic peptide plasma levels, larger RV and lower RV fractional area change than those with echo-PAC ≥1.94 mL/mmHg. They also had a significantly higher rate of ventricular assist device implantation or death, even after adjustment for indices related to HF severity or RV function during a 1-year follow-up period (P<0.01). CONCLUSIONS: Decreased PAC as measured by echocardiography, indicating elevated PAWP and RV dysfunction, predicted poorer outcomes in patients with advanced HF.


Asunto(s)
Ecocardiografía/métodos , Elasticidad , Insuficiencia Cardíaca/fisiopatología , Arteria Pulmonar/fisiopatología , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Presión Esfenoidal Pulmonar , Disfunción Ventricular Derecha
6.
Circ J ; 79(5): 1037-43, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25740501

RESUMEN

BACKGROUND: Feasibility and early results of transfemoral aortic valve implantation using the ACURATE neo/TF(TM)self-expanding stent are reported. METHODS AND RESULTS: The study group of 15 patients (mean age 83.3±6.0) was enrolled with a mean EuroSCORE and STS score of 21.9±11.6% and 7.5±3.1%, respectively. Clinical and echocardiographic evaluations were performed at baseline, discharge, 30 days and 6 months. The primary endpoint was all-cause mortality at 30 days. Transcatheter aortic valve implantation (TAVI) using the ACURATE neo/TF device was successful in 14 patients; 1 patient underwent valve-in-valve implantation because the prosthetic valve embolized during withdrawal of the delivery system. Conversion to surgery, coronary obstruction, peri-operative stroke, and pacemaker implantation did not occur at 30 days. Mean transvalvular gradients at discharge significantly decreased from 44.2±10.5 mmHg (preprocedural) to 7.7±3.1 mmHg (P<0.0001) and effective orifice area significantly increased from 0.77±0.12 to 1.69±0.25 cm(2)(P<0.0001). None or trace paravalvular leak was revealed in 50.0%, and no patient exhibited moderate or higher paravalvular leak. The overall mortality at 30 days and 6 months was 0% and 6.7%, respectively. CONCLUSIONS: A new self-expanding TF TAVI device, ACURATE neo/TF, is safe and effective in the treatment of severe aortic stenosis in elderly patients at high risk for surgery.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino
7.
Circ J ; 79(12): 2713-9, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26460887

RESUMEN

BACKGROUND: Although transcatheter aortic valve implantation (TAVI) is a new alternative treatment with acceptable midterm results for high surgical risk patients, at present performing the procedure in dialysis patients is not reimbursed in Japan. METHODS AND RESULTS: The study group of 17 dialysis patients (mean age, 76.7±5.0 years) underwent TAVI with the SAPIEN/SAPIEN XT. EuroSCORE and STS score were 25.0±19.0% and 15.4±12.3%, respectively. Transiliofemoral and transapical approaches were performed in 7 (41.2%) and 10 patients (58.8%), respectively. ICU and hospital stays after TAVI were 1.8±1.6 and 12.9±12.7 days, respectively. Mean transvalvular gradients at discharge significantly decreased from 45.9±13.3 mmHg to 10.7±4.3 mmHg (P<0.0001) and effective orifice area significantly increased from 0.78±0.17 to 1.69±0.37 cm(2)(P<0.0001). Device success was 87.5%. One patient required a valve-in-valve procedure on 187-postoperative-day for an acute increase in paravalvular leakage caused by initial lower implantation of the device. The overall mortality at 1 year was 0% and clinical efficacies at 30 days, 6 months, and 1 year were 93.8%, 83.3%, and 69.2%, respectively. CONCLUSIONS: Satisfactory early results were achieved with TAVI in Japanese dialysis patients with a high surgical risk, indicating it is a safe and effective alternative for the treatment of aortic valve stenosis in such patients.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Fallo Renal Crónico/terapia , Diálisis Renal , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Pueblo Asiatico , Femenino , Estudios de Seguimiento , Humanos , Japón , Fallo Renal Crónico/complicaciones , Masculino
8.
J Echocardiogr ; 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39102170

RESUMEN

This study aims to develop a new heart failure with preserved ejection fraction (HFpEF) diagnostic algorithm tailored to Asian populations, addressing limitations of current diagnostic models. Existing HFpEF diagnostic algorithms primarily target patients with dyspnea and metabolic comorbidities, such as obesity, which are more prevalent in Western populations. However, in Asian countries, HFpEF cases are less frequently associated with obesity, leading to less prominent dyspnea and more noticeable symptoms such as fatigue. By incorporating exercise stress echocardiography and focusing on early-stage HFpEF, particularly in patients with symptoms beyond dyspnea, we seek to enable early diagnosis and intervention, ultimately extending healthy life expectancy and improving quality of life. The STOP-HFPEF (The Multicenter STudy On a Precise algorithm for diagnosis of Heart Failure with Preserved Ejection Fraction) study is a multicenter prospective observational investigation in Japan. Certified by the Japanese Society of Echocardiography, the study includes participants aged 20 and older who undergo exercise stress echocardiography. The primary goal is to develop a scoring model for diagnosing HFpEF in heart-failure stages A, B, and C. Secondary outcomes will assess the clinical utility of the new diagnostic score by comparing heart-failure incidence, cardiovascular events, and mortality rates.Study registration: Registered at the UMIN registry (UMIN000054565) on 1 July 2024.

9.
J Echocardiogr ; 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38451414

RESUMEN

BACKGROUND: Dilated cardiomyopathy (DCM) presents with diverse clinical courses, hardly predictable solely by the left ventricular (LV) ejection fraction (EF). Longitudinal strain (LS) offers distinct information from LVEF and exhibits various distribution patterns. This study aimed to evaluate the clinical significance of LS distribution patterns in DCM. METHODS: We studied 139 patients with DCM (LVEF ≤ 35%) who were admitted for heart failure (HF). LS distribution was assessed using a bull's eye map and the relative apical LS index (RapLSI), calculated by dividing apical LS by the sum of basal and mid-LS values. We evaluated the associations of LS distribution with cardiac events (cardiac death, LV assist device implantation, or HF hospitalization) and LV reverse remodeling (LVRR), as indicated by subsequent LVEF changes. RESULTS: Twenty six (19%) and 29 (21%) patients exhibited a pattern of relatively apical impaired or preserved LS (defined by RapLSI < 0.25 or > 0.75, signifying a 50% decrease or increase in apical LS compared to other segments), and the remaining patients exhibited a scattered/homogeneously impaired LS pattern. The proportion of new-onset heart failure and LVEF differed between the three groups. During the median 595-day follow-up, patients with relatively-impaired apical LS had a higher rate of cardiac events (both log-rank p < 0.05) and a lower incidence of LVRR (both p < 0.01) compared to patients with other patterns. RapLSI was significantly associated with cardiac event rates after adjusting for age, sex, and new-onset HF or global LS. CONCLUSION: DCM patients with reduced EF and distinct distribution patterns of impaired LS experienced different outcomes.

10.
Sci Rep ; 14(1): 1746, 2024 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-38243047

RESUMEN

The coexistence of heart failure is frequent and associated with higher mortality in patients with type 2 diabetes (T2DM), and its management is a critical issue. The WATCH-DM risk score is a tool to predict heart failure in patients with type 2 diabetes mellitus (T2DM). We investigated whether it could estimate outcomes in T2DM patients with heart failure with preserved ejection fraction (HFpEF). The WATCH-DM risk score was calculated in 418 patients with T2DM hospitalized for HFpEF (male 49.5%, age 80 ± 9 years, HbA1c 6.8 ± 1.0%), and they were divided into the "average or lower" (≤ 10 points), "high" (11-13 points) and "very high" (≥ 14 points) risk groups. We followed patients to observe all-cause death for 386 days (median). We compared the area under the curve (AUC) of the WATCH-DM score for predicting 1-year mortality with that of the Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score and of the Barcelona Bio-Heart Failure Risk (BCN Bio-HF). Among the study patients, 108 patients (25.8%) had average or lower risk scores, 147 patients (35.2%) had high risk scores, and 163 patients (39.0%) had very high risk scores. The Cox proportional hazard model selected the WATCH-DM score as an independent predictor of all-cause death (HR per unit 1.10, 95% CI 1.03 to 1.19), and the "average or lower" risk group had lower mortality than the other groups (p = 0.047 by log-rank test). The AUC of the WATCH-DM for 1-year mortality was 0.64 (95% CI 0.45 to 0.74), which was not different from that of the MAGGIC score (0.72, 95% CI 0.63 to 0.80, p = 0.08) or that of BCN Bio-HF (0.70, 0.61 to 0.80, p = 0.25). The WATCH-DM risk score can estimate prognosis in T2DM patients with HFpEF and can identify patients at higher risk of mortality.


Asunto(s)
Diabetes Mellitus Tipo 2 , Insuficiencia Cardíaca , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Diabetes Mellitus Tipo 2/complicaciones , Volumen Sistólico , Factores de Riesgo , Pronóstico
11.
J Cardiovasc Magn Reson ; 15: 95, 2013 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-24134158

RESUMEN

BACKGROUND: Analysis of left ventricular (LV) mechanical dyssynchrony may provide incremental prognostic information regarding cardiac resynchronization therapy (CRT) response in addition to QRS width alone. Our objective was to quantify LV dyssynchrony using feature tracking post processing of routine cardiovascular magnetic resonance (CMR) cine acquisitions (FT-CMR) in comparison to speckle tracking echocardiography. METHODS: We studied 72 consecutive patients who had both steady-state free precession CMR and echocardiography. Mid-LV short axis CMR cines were analyzed using FT-CMR software and compared with echocardiographic speckle tracking radial dyssynchrony (time difference between the anteroseptal and posterior wall peak strain). RESULTS: Radial dyssynchrony analysis was possible by FT-CMR in all patients, and in 67 (93%) by echocardiography. Dyssynchrony by FT-CMR and speckle tracking showed limits of agreement of strain delays of ± 84 ms. These were large (up to 100% or more) relative to the small mean delays measured in more synchronous patients, but acceptable (mainly <25%) in those with mean delays of >200 ms. Radial dyssynchrony was significantly greater in wide QRS patients than narrow QRS patients by both FT-CMR (radial strain delay 230 ± 94 vs. 77 ± 92* ms) and speckle tracking (radial strain delay 242 ± 101 vs. 75 ± 88* ms, all *p < 0.001). CONCLUSIONS: FT-CMR delivered measurements of radial dyssynchrony from CMR cine acquisitions which, at least for the patients with more marked dyssynchrony, showed reasonable agreement with those from speckle tracking echocardiography. The clinical usefulness of the method, for example in predicting prognosis in CRT patients, remains to be investigated.


Asunto(s)
Ecocardiografía , Imagen por Resonancia Cinemagnética , Disfunción Ventricular Izquierda/diagnóstico , Función Ventricular Izquierda , Adulto , Anciano , Algoritmos , Automatización de Laboratorios , Fenómenos Biomecánicos , Estudios de Factibilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Programas Informáticos , Estrés Mecánico , Factores de Tiempo , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología
12.
Eur Heart J ; 33(21): 2680-91, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22351700

RESUMEN

AIMS: Because benefits of cardiac resynchronization therapy (CRT) appear to be less favourable in non-left bundle branch block (LBBB) patients, this prospective longitudinal study tested the hypothesis that QRS morphology and echocardiographic mechanical dyssynchrony were associated with long-term outcome after CRT. METHODS AND RESULTS: Two-hundred and seventy-eight consecutive New York Heart Association class III and IV CRT patients with QRS ≥120 ms and ejection fraction ≤35% were studied. The pre-specified primary endpoint was death, heart transplant, or left ventricular assist device over 4 years. Dyssynchrony assessed before CRT included interventricular mechanical delay (IVMD) and speckle-tracking radial strain using pre-specified cut-offs for each. Of 254 with baseline quantitative echocardiographic data available, 128 had LBBB, 81 had intraventricular conduction delay (IVCD), and 45 had right bundle branch block (RBBB). Radial dyssynchrony was observed in 85% of the patients with LBBB, 59% with IVCD*, and 40% with RBBB* (*P < 0.01 vs. LBBB). Of 248 (98%) with follow-up, LBBB patients had a significantly more favourable long-term survival than non-LBBB patients. However, non-LBBB patients with dyssynchrony had a more favourable event-free survival than those without dyssynchrony: radial dyssynchrony hazard ratio 2.6, 95% confidence interval (CI) 1.47-4.53 (P = 0.0008) and IVMD hazard ratio 4.9, 95% CI 2.60-9.16 (P = 0.0007). Right bundle branch block patients who lacked dyssynchrony had the least favourable outcome. CONCLUSION: Non-LBBB patients with dyssynchrony had a more favourable long-term survival than non-LBBB patients who lacked dyssynchrony. Mechanical dyssynchrony and QRS morphology are associated with outcome following CRT.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Disfunción Ventricular Izquierda/terapia , Anciano , Análisis de Varianza , Bloqueo de Rama/fisiopatología , Ecocardiografía Doppler/métodos , Electrocardiografía , Femenino , Insuficiencia Cardíaca/terapia , Trasplante de Corazón/estadística & datos numéricos , Humanos , Estimación de Kaplan-Meier , Masculino , Estudios Prospectivos , Volumen Sistólico/fisiología , Resultado del Tratamiento , Disfunción Ventricular Izquierda/fisiopatología
13.
J Arrhythm ; 39(4): 523-530, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37560275

RESUMEN

Background: Sleep apnea (SA) is highly prevalent and should be treated in patients referred for catheter ablation (CA) of atrial fibrillation (AF). Watch-type peripheral arterial tonometry (WP) for home SA testing has demonstrated a high correlation of the apnea-hypopnea index (AHI) with Polysomnography (PSG), but the evidence of its accuracy in AF patients is not adequate. Methods: This study was conducted under a retrospective, single-center, observational design. We included 464 consecutive AF patients (age 65 ± 11 years, 76.5% male, 45.0% paroxysmal-AF) who received both WP and PSG during the periprocedural period of the CA. We compared the AHI using the WP (WP-AHI) to that using PSG (PSG-AHI). Results: The WP-AHI was 25.9 ± 12.7 and PSG-AHI 31.4 ± 18.9 (r = .48). Among 325 patients with a WP-AHI < 30, 116 (35.7%) exhibited a PSG-AHI ≥ 30. Only 12.5% of the patients were indicated for continuous positive airway pressure (CPAP) treatment only by the WP-AHI, while 70.9% were indicated for CPAP by the PSG-AHI according to the Japanese health insurance system. The best cut-off value of the WP-AHI was 18.1 to predict a PSG-AHI ≥ 20 with an area under the curve of 0.72 (95% confidence interval, 0.67-0.76). Conclusions: The WP-AHI and PSG-AHI were weakly correlated in AF patients receiving CA. About one-third of the patients with moderate SA using the WP was diagnosed with severe SA evaluated by PSG. The majority required PSG for the CPAP indication.

14.
Am J Cardiol ; 191: 66-75, 2023 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-36641982

RESUMEN

Functional mitral regurgitation (FMR) negatively impacts the prognosis in patients with atrial fibrillation (AF) and reduced left ventricular (LV) ejection fraction (LVEF). Although structural reverse remodeling after AF ablation can reduce FMR severity, the prognostic impact of FMR and its evolution remain unclear. Of 491 patients with baseline LVEF <50% who underwent first-time AF ablation, 134 patients (27%) had grade 2 to 4 FMR at baseline. Among them, 88 patients (66%) exhibited FMR improvement to grade 0 to 1 FMR 6 months after AF ablation. Conversely, among 357 with baseline grade 0 to 1 FMR, 13 patients (3.6%) exhibited FMR worsening to grade 2 to 4 FMR despite AF ablation. Assessment with multidetector computed tomography revealed that an increase in the left atrial emptying fraction (odds ratio 3.55 per 10% increase; 95% confidence interval 2.12 to 5.95) and a reduction in the LV end-diastolic volume index (1.35 per 10-ml/m2 decrease; 1.04 to 1.76) were identified as contributors to the FMR improvement. During a follow-up of 43 months, patients with postprocedural grade 2 to 4 FMR more frequently experienced hospitalizations for heart failure or cardiovascular death than those with grade 0 to 1 FMR (30.5% vs 4.6%, log-rank p <0.001). An age-adjusted multivariate Cox regression analysis including baseline and postprocedural FMR revealed that postprocedural grade 2 to 4 FMR (hazard ratio, 3.24; 95% confidence interval 1.43 to 7.35) was significantly associated with unfavorable events. In conclusion, AF ablation modified and often improved FMR severity in patients with reduced LVEF. Residual grade 2 to 4 FMR 6 months after AF ablation was associated with a poor prognosis.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia de la Válvula Mitral , Disfunción Ventricular Izquierda , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Pronóstico , Volumen Sistólico
15.
Sci Rep ; 13(1): 22196, 2023 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-38097659

RESUMEN

The reproducibility of longitudinal strain measured by 2D speckle tracking echocardiography (2DSTE) may be affected by ultrasound settings. This study investigated the effect of transmit ultrasound frequency on global longitudinal strain (GLS) by 2DSTE. Apical, 2- and 4-chamber, and long-axis views were obtained in consecutive 162 patients using Philips ultrasound devices. Three different frequency presets were used sequentially: high resolution (HRES, 1.9 to 2.1 MHz), general (HGEN, 1.6 to 1.8 MHz), and penetration mode (HPEN, 1.3 to 1.6 MHz). GLS values were determined for each preset using the Philips Q-station software, resulting in GLS-HRES, GLS-HGEN, and GLS-HPEN. Among the 151 patients with successfully measured GLS, a significant difference in GLS was observed among the three presets (p < 0.0001). GLS-HRES (- 17.9 ± 4.4%) showed a slightly smaller magnitude compared to GLS-HGEN (- 18.8 ± 4.5%, p < 0.0001) and GLS-HPEN (- 18.8 ± 4.5%, p < 0.0001), with absolute differences of 1.1 ± 1.0% and 1.1 ± 1.2%, respectively. This variation in GLS with frequency was evident in patients with both optimal (n = 104) and suboptimal (n = 47) image quality and remained consistent regardless of ultrasound devices, ischemic etiology, or ejection fraction. In conclusion, ultrasound frequency had only a modest effect on GLS measurements. GLS may be reliably assessed in most cases regardless of the ultrasound frequency used.


Asunto(s)
Disfunción Ventricular Izquierda , Función Ventricular Izquierda , Humanos , Reproducibilidad de los Resultados , Tensión Longitudinal Global , Ecocardiografía/métodos , Programas Informáticos , Ventrículos Cardíacos/diagnóstico por imagen
16.
J Am Heart Assoc ; 12(16): e029717, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37581389

RESUMEN

Background Prognostic implications of transcatheter aortic valve implantation (TAVI) in low-gradient (LG) aortic stenosis (AS) remain controversial. The authors hypothesized that differences in cardiac functional recovery may solve this ongoing controversy. The aim was to evaluate clinical outcomes and the response of left ventricular (LV) function following TAVI in patients with LG AS. Methods and Results This multicenter retrospective study included 1742 patients with severe AS undergoing TAVI between January 2015 and March 2019. Patients were subdivided into low-flow (LF) LG, normal-flow (NF) LG, LF high-gradient, and NF high-gradient AS groups according to the mean gradient of the aortic valve (LG <40 mm Hg) and LV stroke volume index (LF <35 mL/m2). Outcomes and changes in echocardiographic parameters after TAVI were compared between the groups. A total of 227 patients (13%) had reduced ejection fraction, and 486 patients (28%) had LG AS (LF-LG 143 [8%]; NF-LG 343 [20%]). During a median follow-up period of 747 days, 301 patients experienced a composite end point of cardiovascular death and rehospitalization for cardiovascular events, which was higher in the LF-LG and NF-LG groups than in the high-gradient groups. LG AS was independently associated with the primary outcome (hazard ratio, 1.69; P<0.001). Among 1239 patients with follow-up echocardiography, LG AS showed less improvement in the LV mass index and LV end-diastolic volume compared with high-gradient AS after 1 year, while LV recovery was similar between the LF AS and NF AS groups. Conclusions LG AS was associated with poorer outcomes and LV recovery, regardless of flow status after TAVI. Careful evaluation of AS severity may be required in LG AS to provide TAVI within the appropriate time and advanced care afterward.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Función Ventricular Izquierda/fisiología , Volumen Sistólico/fisiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Índice de Severidad de la Enfermedad
17.
J Cardiol ; 80(3): 218-225, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35307223

RESUMEN

BACKGROUND: The predictive value of echocardiographic parameters for early worsening heart failure (WHF), worsening of symptoms of heart failure requiring intensification of therapy during an admission for acute decompensated heart failure (ADHF), has not been elucidated. METHODS: Sixteen centers in Japan prospectively enrolled 303 ADHF hospitalized patients who did not receive positive inotropic agents as an initial therapy. Physical and Doppler echocardiographic examinations were performed before the initial therapy and the association of low output findings and occurrence of early WHF were tested. RESULTS: Early WHF occurred in 63 patients with a median duration of 6 (IQR: 2-23) hours from the administration of the initial therapy. In patients with left ventricular (LV) ejection fraction <40% (N = 153), echocardiographic stroke volume index, and cardiac index showed greater c-index [95% confidence interval, 0.71 (0.61-0.79) and 0.72 (0.63-0.80), respectively] compared to single low perfusion finding (symptomatic hypotension, reduced pulse pressure, and impaired mentation) other than cool extremities. When physical findings were combined (low perfusion score), the predictive ability improved to the similar levels of echocardiographic LV output parameters [c-index: 0.69 (0.60-0.76)]. However, addition of cardiac index significantly improved the prognostic ability when added to low perfusion score [0.82 (0.74-0.87), p < 0.001]. In contrast, in patients with LV ejection fraction ≥40% (N = 150), low perfusion score, rather than LV output parameters, was predictive of early WHF [c-index: 0.73 (0.56-0.85)]. CONCLUSIONS: We demonstrated the predictive value of echocardiographic LV output indices for early WHF in ADHF patients with LV systolic dysfunction. These data support the motivation for routine use of echocardiography for initial assessment of ADHF.


Asunto(s)
Insuficiencia Cardíaca , Ecocardiografía/métodos , Ecocardiografía Doppler , Humanos , Volumen Sistólico , Función Ventricular Izquierda
18.
Heart Fail Rev ; 16(4): 397-410, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21152974

RESUMEN

Cardiac resynchronization therapy (CRT) is believed to benefit patients by primarily correcting heterogeneity in regional ventricular mechanical contraction, known as dyssynchrony. Although many symptomatic heart failure patients with depressed left ventricular ejection fraction and widened electrocardiographic QRS complexes have clinical improvement from CRT, a significant subset of approximately one-third do not seem to respond. Because the degree of mechanical dyssynchrony may be widely variable, interest has remained high to attempt to improve patient selection for CRT using cardiac imaging as a means to quantify dyssynchrony. This article will review the principal echocardiographic methods of dyssynchrony analysis by tissue Doppler imaging, (opposing wall delay, 12-site standard deviation or Yu index, and longitudinal strain), routine pulsed-Doppler (interventricular mechanical delay, pre-ejection delay and filling time ratio), and speckle tracking (including radial, circumferential, and longitudinal strain). In addition, dyssynchrony analysis by cardiac magnetic resonance imaging is introduced as a potential alternative technique. The technical features, strengths and limitations, and clinical evidence for these methods are discussed, including a practical clinical approach.


Asunto(s)
Estimulación Cardíaca Artificial , Insuficiencia Cardíaca/terapia , Miocardio , Ecocardiografía Doppler/instrumentación , Electrocardiografía , Insuficiencia Cardíaca/patología , Humanos , Imagen por Resonancia Magnética , Volumen Sistólico , Función Ventricular Izquierda
19.
Circ J ; 75(5): 1113-9, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21389636

RESUMEN

BACKGROUND: Second-generation drug-eluting stents (DES) are expected to show better arterial repair than older DES. We angioscopically compared the biodegradable polymer-coated biolimus A9-eluting stent (BES) and durable polymer-coated sirolimus-eluting stent (SES) to explore differences in arterial repair. METHODS AND RESULTS: Angioscopy was performed 9 ± 1 months after 15 BES and 16 SES were implanted initially in the native coronary artery. Heterogeneity of neointimal coverage (NIC) as well as the dominant NIC grade was examined. NIC was defined as: grade 0 = fully visible struts; grade 1 = struts bulging into the lumen, but covered; grade 2 = embedded, but translucent struts; grade 3 = invisible struts. Heterogeneity was judged when the NIC grade varied ≥ 1. In-stent late loss (0.06 ± 0.23 vs. 0.07 ± 0.18 mm, P = 0.80), and dominant NIC grade (1.5 ± 0.8 vs. 1.3 ± 0.7, P = 0.45) were similar for BES and SES. Within the stents, NIC was more heterogeneous in SES than in BES (P = 0.035). 80% of BES showed homogeneous NIC, while 56% of SES had heterogeneous NIC. CONCLUSIONS: BES showed limited late loss similar to that for SES. Nonetheless, the NIC with BES was more homogeneous than that with SES. Biodegradable polymer-coated BES may have an advantage in homogeneous NIC.


Asunto(s)
Angioscopía , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos/normas , Sirolimus/análogos & derivados , Sirolimus/administración & dosificación , Anciano de 80 o más Años , Materiales Biocompatibles Revestidos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polímeros , Resultado del Tratamiento , Túnica Íntima , Cicatrización de Heridas
20.
J Echocardiogr ; 19(4): 195-204, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34133007

RESUMEN

Dyspnea is one of the major symptoms encountered in the emergency department, and lung ultrasound (LUS) is recommended for the rapid diagnosis of the underlying disease. B-lines, the "comet-tail"-like vertical lines moving with respiration, are an ultrasound finding relevant to the pulmonary congestion. They may be observed in the normal lung, but bilateral, ≥ 3 B-lines are considered pathological. B-lines with lung sliding (B profile) are a specific sign of heart failure, while B-lines with abolished lung sliding (B' profile) are related with the lung diseases such as acute respiratory distress syndrome. B profile is reported to detect pulmonary edema with about 95% sensitivity and 95% specificity in patients with dyspnea. LUS also can assess the severity of pulmonary congestion semi-quantitatively by counting the number of B-lines or that of positive areas. Whereas the original BLUE protocol requires scanning at 12 zones on the chest, more rapid 8- or 6-zone scan is sufficient for the diagnosis of heart failure, and 2- or 4-zone scan may be used for the critical patients. LUS may be used for the evaluation of heart failure treatment, or can be performed as a part of exercise stress test. LUS can be performed easily and rapidly at the bedside using almost any kind of ultrasound apparatus, and it should be performed more widely in the daily practice as well as in the emergent department.


Asunto(s)
Insuficiencia Cardíaca , Edema Pulmonar , Disnea/diagnóstico por imagen , Disnea/etiología , Insuficiencia Cardíaca/diagnóstico por imagen , Humanos , Pulmón/diagnóstico por imagen , Edema Pulmonar/diagnóstico por imagen , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA