Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(1): 7-15, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37794818

RESUMEN

INTRODUCTION: High-power short-duration (HPSD) ablation at 50 W, guided by ablation index (AI) or lesion size index (LSI), and a 90 W/4 s very HSPD (vHPSD) setting are available for atrial fibrillation (AF) treatment. Yet, tissue temperatures during ablation with different catheters around venoatrial junction and collateral tissues remain unclear. METHODS: In this porcine study, we surgically implanted thermocouples on the epicardium near the superior vena cava (SVC), right pulmonary vein, and esophagus close to the inferior vena cava. We then compared tissue temperatures during 50W-HPSD guided by AI 400 or LSI 5.0, and 90 W/4 s-vHPSD ablation using THERMOCOOL SMARTTOUCH SF (STSF), TactiCath ablation catheter, sensor enabled (TacthCath), and QDOT MICRO (Qmode and Qmode+ settings) catheters. RESULTS: STSF produced the highest maximum tissue temperature (Tmax ), followed by TactiCath, and QDOT MICRO in Qmode and Qmode+ (62.7 ± 12.5°C, 58.0 ± 10.1°C, 50.0 ± 12.1°C, and 49.2 ± 8.4°C, respectively; p = .005), achieving effective transmural lesions. Time to lethal tissue temperature ≥50°C (t-T ≥ 50°C) was fastest in Qmode+, followed by TacthCath, STSF, and Qmode (4.3 ± 2.5, 6.4 ± 1.9, 7.1 ± 2.8, and 7.7 ± 3.1 s, respectively; p < .001). The catheter tip-to-thermocouple distance for lethal temperature (indicating lesion depth) from receiver operating characteristic curve analysis was deepest in STSF at 5.2 mm, followed by Qmode at 4.3 mm, Qmode+ at 3.1 mm, and TactiCath at 2.8 mm. Ablation at the SVC near the phrenic nerve led to sudden injury at t-T ≥ 50°C in all four settings. The esophageal adventitia injury was least deep with Qmode+ ablation (0.4 ± 0.1 vs. 0.8 ± 0.4 mm for Qmode, 0.9 ± 0.3 mm for TactiCath, and 1.1 ± 0.5 mm for STSF, respectively; p = .005), correlating with Tmax . CONCLUSION: This study revealed distinct tissue temperature patterns during HSPD and vHPSD ablations with the three catheters, affecting lesion effectiveness and collateral damage based on Tmax and/or t-T ≥ 50°C. These findings provide key insights into the safety and efficacy of AF ablation with these four settings.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Porcinos , Animales , Temperatura , Vena Cava Superior/cirugía , Catéteres , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Calor , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 34(2): 369-378, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36527433

RESUMEN

INTRODUCTION: Neither the actual in vivo tissue temperatures reached with 90 W/4 s-very high-power short-duration (vHPSD) ablation for atrial fibrillation nor the safety and efficacy profile have been fully elucidated. METHODS: We conducted a porcine study (n = 15) in which, after right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We compared tissue temperatures close to a QDOT MICRO catheter, between during 90 W/4 s-vHPSD ablation during ablation index (AI: target 400)-guided 50 W-HPSD ablation, both targeting a contact force of 8-15 g. RESULTS: Maximum tissue temperature reached during 90 W/4 s-vHPSD ablation did not differ significantly from that during 50 W-HPSD ablation (49.2 ± 8.4°C vs. 50.0 ± 12.1°C; p = .69) and correlated inversely with distance between the catheter tip and the thermocouple, regardless of the power settings (r = -0.52 and r = -0.37). Lethal temperature (≥50°C) was best predicted at a catheter tip-to-thermocouple distance cut-point of 3.13 and 4.27 mm, respectively. All lesions produced by 90 W/4 s-vHPSD or 50 W-HPSD ablation were transmural. Although there was no difference in the esophageal injury rate (50% vs. 66%, p = .80), the thermal lesion was significantly shallower with 90 W/4 s-vHPSD ablation than with 50W-HPSD ablation (381.3 ± 127.3 vs. 820.0 ± 426.1 µm from the esophageal adventitia; p = .039). CONCLUSION: Actual tissue temperatures reached with 90 W/4 s-vHPSD ablation appear similar to those with AI-guided 50 W-HPSD ablation, with the distance between the catheter tip and target tissue being shorter for the former. Although both ablation settings may create transmural lesions in thin atrial tissues, any resulting esophageal thermal lesions appear shallower with 90 W/4 s-vHPSD ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Animales , Porcinos , Temperatura , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Vena Cava Superior , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Esófago/cirugía , Esófago/lesiones , Venas Pulmonares/cirugía , Resultado del Tratamiento
3.
J Cardiovasc Electrophysiol ; 34(1): 108-116, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36300696

RESUMEN

BACKGROUND: Neither the actual in vivo tissue temperatures reached with lesion size index (LSI)-guided high-power short-duration (HPSD) ablation for atrial fibrillation nor the safety profile has been elucidated. METHODS: We conducted a porcine study (n = 7) in which, after right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We compared tissue temperatures reached during 50 W-HPSD ablation with those reached during standard (30 W) ablation, both targeting an LSI of 5.0 (5-15 g contact force). RESULTS: Tmax  (maximum tissue temperature when the thermocouple was located ≤5 mm from the catheter tip) reached during HPSD ablation was modestly higher than that reached during standard ablation (58.0 ± 10.1°C vs. 53.6 ± 9.2°C; p = .14) and peak tissue temperature correlated inversely with the distance between the catheter tip and the thermocouple, regardless of the power settings (HPSD: r = -0.63; standard: r = -0.66). Lethal temperature (≥50°C) reached 6.3 ± 1.8 s and 16.9 ± 16.1 s after the start of HPSD and standard ablation, respectively (p = .002), and it was best predicted at a catheter tip-to-thermocouple distance cut point of 2.8 and 5.3 mm, respectively. All lesions produced by HPSD ablation and by standard ablation were transmural. There was no difference between HPSD ablation and standard ablation in the esophageal injury rate (70% vs. 75%, p = .81), but the maximum distance from the esophageal adventitia to the injury site tended to be shorter (0.94 ± 0.29 mm vs. 1.40 ± 0.57 mm, respectively; p = .09). CONCLUSIONS: Actual tissue temperatures reached with LSI-guided HPSD ablation appear to be modestly higher, with a shorter distance between the catheter tip and thermocouple achieving lethal temperature, than those reached with standard ablation. HPSD ablation lasting <6 s may help minimize lethal thermal injury to the esophagus lying at a close distance.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Porcinos , Animales , Temperatura , Vena Cava Superior , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Esófago/cirugía , Esófago/lesiones , Catéteres , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Resultado del Tratamiento
4.
Int Heart J ; 64(3): 453-461, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37258121

RESUMEN

The effects of recombinant semaphorin 3A (Sema3A) on myocardial contractility and electrical remodeling in mice with isoproterenol (ISP) -induced heart failure were investigated.C57BL/6J mice intraperitoneally received ISP (480 mg/kg/day, ISP group; n = 24) or saline (control group; n = 31) for 14 days. Twenty-one ISP-treated mice received 0.5 mg/kg Sema3A intravenously on days 7 and 11 (ISP+Sema3A group). The sympathetic nervous system was activated upon ISP treatment, but was reduced upon Sema3A administration. Greater myocardial tissue fibrosis was observed in the ISP group than in the control group. However, fibrosis was not significantly different between the ISP+Sema3A and control groups. Fractional shortening of the left ventricle was lower in the ISP group than in the control group and was restored in the ISP+Sema3A group (control, 53 ± 8%; ISP, 37 ± 7%; ISP+Sema3A, 48 ± 3%; P < 0.05). Monophasic action potential duration at 20% repolarization (MAPD20) was prolonged in the ISP group (compared to control group), but this was reversed upon Sema3A administration (control, 29 ± 3 ms; ISP, 35 ± 6 ms; ISP+Sema3A, 29 ± 3 ms; P < 0.05). qPCR revealed Kv4.3, KChIP2, and SERCA2 downregulation in the ISP group and upregulation in the ISP+Sema3A group; however, Western blotting revealed similar changes only for Kv4.3 (P < 0.05).Intravenous Sema3A may maintain myocardial contractility by suppressing the sympathetic innervation of the myocardium and reducing myocardial tissue damage, in addition to restoring MAPD via Kv4.3 upregulation.


Asunto(s)
Remodelación Atrial , Insuficiencia Cardíaca , Ratones , Animales , Isoproterenol , Semaforina-3A , Ratones Endogámicos C57BL , Insuficiencia Cardíaca/inducido químicamente , Insuficiencia Cardíaca/tratamiento farmacológico
5.
J Cardiovasc Electrophysiol ; 33(1): 55-63, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34713525

RESUMEN

BACKGROUND: Actual in vivo tissue temperatures and the safety profile during high-power short-duration (HPSD) ablation of atrial fibrillation have not been clarified. METHODS: We conducted an animal study in which, after a right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We recorded tissue temperatures during a 50 W-HPSD ablation and 30 W-standard ablation targeting an ablation index (AI) of 400 (5-15 g contact force). RESULTS: Maximum tissue temperatures reached with HSPD ablation were significantly higher than that reached with standard ablation (62.7 ± 12.5 vs. 52.7 ± 11.4°C, p = 0.033) and correlated inversely with the distance between the catheter tip and thermocouple, regardless of the power settings (HPSD: r = -0.71; standard: r = -0.64). Achievement of lethal temperatures (≥50°C) was within 7.6 ± 3.6 and 12.1 ± 4.1 s after HPSD and standard ablation, respectively (p = 0.003), and was best predicted at cutoff points of 5.2 and 4.4 mm, respectively. All HPSD ablation lesions were transmural, but 19.2% of the standard ablation lesions were not (p = 0.011). There was no difference between HPSD and standard ablation regarding the esophageal injury rate (30% vs. 33.3%, p > 0.99), with the injury appearing to be related to the short distance from the catheter tip. CONCLUSIONS: Actual tissue temperatures reached with AI-guided HPSD ablation appeared to be higher with a greater distance between the catheter tip and target tissue than those with standard ablation. HPSD ablation for <7 s may help prevent collateral tissue injury when ablating within a close distance.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Animales , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Temperatura , Resultado del Tratamiento , Vena Cava Superior/cirugía
6.
Circ J ; 86(2): 233-242, 2022 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-34219078

RESUMEN

BACKGROUND: It is unclear whether there are differences in the clinical factors between atrial fibrillation (AF) recurrence and adverse clinical events (AEs), including stroke/transient ischemic attack (TIA), major bleeding, and death, after AF ablation.Methods and Results:We examined the data from a retrospective multicenter Japanese registry conducted at 24 cardiovascular centers between 2011 and 2017. Of the 3,451 patients (74.1% men; 63.3±10.3 years) who underwent AF ablation, 1,046 (30.3%) had AF recurrence and 224 (6.5%) suffered AEs (51 strokes/TIAs, 71 major bleeding events, and 36 deaths) over a median follow-up of 20.7 months. After multivariate adjustment, female sex, persistent and long-lasting persistent AF (vs. paroxysmal AF), and stepwise increased left atrial diameter (LAd) quartiles were significantly associated with post-ablation recurrences. A multivariate analysis revealed that an age ≥75 years (vs. <65 years), body weight <50 kg, diabetes, vascular disease, left ventricular (LV) ejection fraction <40% (vs. ≥50%), Lad ≥44 mm (vs. <36 mm), and creatinine clearance <50 mL/min were independently associated with AE incidences, but not with recurrences. CONCLUSIONS: This study disclosed different determinants of post-ablation recurrence and AEs. Female sex, persistent AF, and enlarged LAd were determinants of post-ablation recurrence, whereas an old age, comorbidities, and LV and renal dysfunction rather than post-ablation recurrence were AEs determinants. These findings will help determine ablation indications and post-ablation management.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Ataque Isquémico Transitorio , Accidente Cerebrovascular , Anciano , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Hemorragia/etiología , Humanos , Ataque Isquémico Transitorio/etiología , Masculino , Recurrencia , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
7.
Heart Vessels ; 37(8): 1411-1417, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35133499

RESUMEN

Some patients with pacemakers present with first-degree atrioventricular (AV) block. To avoid right ventricular (RV) pacing, preserving intrinsic AV conduction as much as possible is recommended. However, there is no clear cutoff AV interval to determine whether intrinsic AV conduction should be preserved or RV pacing should be delivered. This study aimed to compare a pacing mode-preserving, intrinsic AV conduction with the DDD mode delivering RV pacing in terms of echocardiographic parameters in patients with first-degree AV block and to investigate whether RV pacing induces heart failure (HF). Stroke volume (SV) was measured to determine the optimal AV delay with the intrinsic AV conduction rhythm and the DDD pacing delivering RV pacing. Echocardiographic evaluation was performed for 6-month follow-up period. Seventeen patients were studied. At baseline, mean intrinsic PQ interval was 250 ± 40 ms. SV was greater with RV pacing with optimal AV delay of 160 ms than with intrinsic AV conduction rhythm in all patients. Therefore, pacemakers were set to the DDD to deliver RV pacing. During follow-up, seven patients developed HF. Mean baseline E/E' ratio in patients who developed HF (HF group) during RV pacing was higher than in patients without HF (non = HF group; 17.9 ± 8 versus 11.5 ± 2, P = 0.018) Even within HF group patients without a high baseline E/E' ratio, it increased with RV pacing (22.2 ± 6 versus 11.6 ± 2; P < 0.001). In patients with pacemaker and first-degree AV block, RV pacing with the optimal AV delay of 160 ms increased SV. However, the risk of HF may be increased with RV pacing if the E/E' ratio is > 15 during intrinsic AV conduction or RV pacing. RV pacing should be avoided in patients with high E/E' ratio under intrinsic AV conduction or RV pacing.


Asunto(s)
Bloqueo Atrioventricular , Insuficiencia Cardíaca , Marcapaso Artificial , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos , Volumen Sistólico
8.
Heart Vessels ; 37(7): 1136-1145, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35066673

RESUMEN

Despite emerging recognition of interactions between heart failure (HF) and liver dysfunction, the impact of cardiac hepatopathy on patients with HF undergoing cardiac resynchronization therapy (CRT) has not been fully elucidated. Albumin-bilirubin (ALBI) score is a new assessment of liver function. The relationship between liver dysfunction severity based on ALBI score and clinical outcomes of patients with HF receiving CRT is unclear. Clinical records of 274 patients who underwent CRT device implantation between March 2003 and October 2020 were retrospectively investigated. ALBI score was calculated based on serum albumin and total bilirubin levels obtained before CRT device implantation. Patients were divided into three groups based on ALBI score: first tertile (ALBI ≤ - 2.62, n = 91)), second tertile (- 2.62 < ALBI < - 2.13, n = 92), and third tertile (ALBI ≥ - 2.13, n = 91). The study endpoint was all-cause mortality. The third tertile group had more advanced NYHA functional class, lower hemoglobin levels, and higher total bilirubin, aspartate aminotransferase, γ-glutamyl transferase, and N-terminal Pro-B-type natriuretic peptide levels (all p < 0.05). The third tertile group also had a higher prevalence of moderate or severe tricuspid regurgitation and higher tricuspid regurgitation pressure gradient (all p < 0.05). CRT response rates were significantly lower in the third tertile group. During a median (interquartile range) follow-up of 30 (9-60) months, 104 (37.9%) patients died. The third tertile group had significantly higher rates of all-cause mortality (log-rank p < 0.001). Higher ALBI score was significantly associated with all-cause mortality, even after adjusting for clinically relevant factors, a conventional validated risk score, and echocardiographic parameters related to right HF (all p < 0.01). Higher ALBI score before CRT device implantation is associated with HF severity, hepatic congestion and impairment due to right HF, lower CRT response, and higher all-cause mortality in CRT recipients.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Bilirrubina , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Pronóstico , Estudios Retrospectivos , Albúmina Sérica , Insuficiencia de la Válvula Tricúspide/complicaciones
9.
Heart Vessels ; 37(5): 802-811, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34709460

RESUMEN

Although a left atrial posterior wall isolation (LAPWI) in addition to a pulmonary vein isolation is a well-accepted option for persistent atrial fibrillation (AF), a complete isolation can be challenging. This study aimed to evaluate the performance of a modified ablation index (AI) (AI/bipolar voltage along the ablation line) for predicting a durable LAPWI. The study included 55 consecutive patients, aged 65 ± 11 years, who underwent an electroanatomic mapping-guided LAPWI of AF. The association between the gaps (first-pass LAPWI failure and/or acute LAPW reconnections), voltage amplitude along the roof and floor lines, and thickness of the LAPW was investigated. Gaps occurred in 22 patients (40%) and in 26 (8%) of the 330 line segments. Gaps were associated with a relatively high bipolar voltage (3.38 ± 1.83 vs. 1.70 ± 1.12 mV, P < 0.0001) and thick LA wall (2.52 ± 1.15 vs. 1.42 ± 0.44 mm, P < 0.0001). A modified AI ≤ 199 AU/mV, bipolar voltage ≥ 2.64 mV, wall thickness ≥ 2.04 mm, and roof ablation line ≥ 43.4 mm well predicted gaps (AUCs: 0.783, 0.787, 0.858, and 0.752, respectively). A high-voltage zone, thick LAPW, and long roof ablation line appeared to be determinants of gaps, and a modified AI ≥ 199 AU/mV along the ablation lines appeared to predict an acute durable LAPWI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos/cirugía , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
10.
Int Heart J ; 63(2): 393-397, 2022 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-35296616

RESUMEN

Sleep apnea syndrome (SAS) is a condition in which apnea and hypoventilation at night cause hypoxemia and impaired wakefulness during the day, resulting in a general malaise and dozing. Sleep apnea has been implicated in the development of hypertension, ischemic heart disease, arrhythmia, heart failure, and cerebrovascular disease.1) Approximately 50% of patients with sleep-disordered breathing have an arrhythmia. In severe cases with an apnea-hypopnea index (AHI) of 30 or more, the frequency of arrhythmias during sleep is two to four times that of individuals without SAS. Bradyarrhythmias such as sinus bradycardia, sinus arrest, and atrioventricular block occurs at night in about 5%-10% of patients with sleep-disordered breathing.2)During nocturnal sleep, vagal excitation causes excessive muscle relaxation of the upper airway, leading to periodic airway diameter reduction, which increases snoring and obstructive apnea. As a result, hypoxemia is likely, further increasing vagal tone and leading to bradycardia. An increase in ventilation rate and volume quickly compensates for the decrease in arterial partial pressure of oxygen during apnea, which leads to new bradycardia due to a decrease in the partial pressure of oxygen in arterial blood, which suppresses vagal tone and respiration.3)We experienced a case of a 44-year-old patient with bradyarrhythmia that might be associated with SAS. After continuous positive airway pressure treatment, AHI decreased, and very long cardiac arrests resolved.


Asunto(s)
Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Adulto , Arritmias Cardíacas/complicaciones , Bradicardia/diagnóstico , Bradicardia/etiología , Bradicardia/terapia , Humanos , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/diagnóstico , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/terapia
11.
J Cardiovasc Electrophysiol ; 32(6): 1678-1686, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33772922

RESUMEN

INTRODUCTION: Preferential pathway conduction is mostly detected as fractionated presystolic-potentials preceding the QRS during premature ventricular contractions (PVCs) and late-potentials during sinus rhythm (SR), but the electrophysiologic mechanisms and significance of these potentials have not been fully clarified. We describe a PVC case series in which the preferential pathway conduction was three-dimensionally visualized. METHODS: Five PVCs (two from the left coronary cusp, two from the commissure of the left and right coronary cusps, and one from the pulmonary artery) in four patients for which a fractionated presystolic-potential during the PVCs and late-potential during SR were recorded at the successful ablation site were reviewed, and three-dimensional coherent activation maps with the conduction velocity vector during the PVCs and SR were reconstructed. RESULTS: At the successful ablation site, an "M"-shaped discrete presystolic-potential and "W"-shaped discrete late-potential were recorded in all patients. The configuration of the inverted electrogram of the presystolic-potential was similar to that of the electrogram exhibiting the late-potential. We created coherent activation maps annotating the onset of the presystolic-potentials during the PVCs and offset of the late-potentials during SR, which suggested bidirectional conduction of the preferential pathway connecting the PVC origin to the myocardium. CONCLUSION: Detailed activation mapping of these PVCs is consistent with the presence of fibers along the aortic or pulmonic valve ring that have preferential directions for conduction. PVCs produce a presystolic-potential. In SR, the fiber is activated late and from the opposite direction, producing an inverted potential inscribed on the end of the QRS.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Frecuencia Cardíaca , Humanos , Imagenología Tridimensional , Arteria Pulmonar , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
12.
J Cardiovasc Electrophysiol ; 32(8): 2275-2284, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33969564

RESUMEN

BACKGROUND: Although low-voltage zones (LVZs) in the left atrium (LA) are considered arrhythmogenic substrates in some patients with atrial fibrillation (AF), the pathophysiologic factors responsible for LVZ formations remain unclear. OBJECTIVE: To elucidate the anatomical relationship between the LA and ascending aorta responsible for anterior LA wall remodeling. METHODS: We assessed the relationship between existence of LVZs on the anterior LA wall and the three-dimensional computed tomography image measurements in 102 patients who underwent AF ablation. RESULTS: Twenty-nine patients (28%) had LVZs grearer than 1.0 cm2 on the LA wall in the LA-ascending aorta contact area (LVZ group); no LVZs were seen in the other 73 patients (no-LVZ group). The LVZ group (vs. no-LVZ group) had a smaller aorta-LA angle (21.0 ± 7.7° vs. 24.9 ± 7.1°, p = .015), greater aorta-left-ventricle (LV) angle (131.3 ± 8.8° vs. 126.0 ± 7.9°; p = .005), greater diameter of the noncoronary cusp (NCC; 20.4 ± 2.2 vs. 19.3 ± 2.5 mm; p = .036), thinner LA wall-thickness adjacent to the NCC (2.3 ± 0.7 vs. 2.8 ± 0.8 mm; p = .006), and greater cardiothoracic ratio (percentage of the area in the thoracic area, 40.1 ± 7.1% vs. 35.4 ± 5.7%, p < .001). The aorta-LA angle correlated positively with the patients' body mass index (BMI), and the aorta-LV angle correlated negatively with the body weight and BMI. CONCLUSION: Deviation of the ascending aorta's course and distention of the NCC appear to be related to the development of LA anterior wall LVZs in the LA-ascending aorta contact area. Mechanical pressure exerted by extracardiac structures on the LA along with the limited thoracic space may contribute to the development of LVZs associated with AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Aorta/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos
13.
J Cardiovasc Electrophysiol ; 32(2): 260-269, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33382509

RESUMEN

INTRODUCTION: Hot-balloon ablation depends solely on thermal conduction, and myocardial tissue is ablated by only conductive heating from the balloon surface. Despite growing clinical evidence of the efficacy and safety of hot-balloon ablation for atrial fibrillation (AF), the actual tissue temperature and the mechanism of heating during such ablation has not been clarified. To determine, by means of a porcine study, the temperatures of tissues targeted during hot-balloon ablation of AF performed with hot-balloon set temperatures of 73°C or 70°C, in accordance with the temperatures now used clinically. METHODS: After a right thoracotomy, thermocouples with markers were implanted epicardially on the superior vena cava (SVC) and pulmonary veins (PVs) in six pigs. The tissue temperatures during hot-balloon ablation (balloon set temperatures of 73°C and 70°C, 180 s/PV) were recorded, and the maximum tissue temperatures and fluoroscopically measured distance from the balloon surface to the target tissues were assessed. RESULTS: Sixteen SVC- and 18 PV-targeted energy deliveries were performed. Full-thickness circumferential PV lesions were created with all hot-balloon applications. A significant inverse relation was found between the recorded tissue temperatures and distance (r = -.67; p < .001) from the balloon surface. No tissue temperature exceeded either of the balloon set temperatures. The best distance cutoff value for achieving lethal tissue temperatures more than 50°C was 3.6 mm. CONCLUSION: The hot-balloon set temperature, energy delivery time, and tissue temperature data obtained in this porcine study supported the clinical efficacy and safety of the hot-balloon ablation as currently practiced in patients with AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Animales , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/cirugía , Porcinos , Resultado del Tratamiento , Vena Cava Superior
14.
J Cardiovasc Electrophysiol ; 32(4): 889-899, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33600010

RESUMEN

BACKGROUND: How obesity and epicardial fat influence atrial fibrillation (AF) is unknown. METHODS: To investigate the effect of obesity/epicardial fat on the AF substrate, we divided 20 beagle dogs of normal weight into four groups (n = 5 each): one of the four groups (Obese-rapid atrial pacing [RAP] group) served as a novel canine model of obesity and AF. The other three groups comprised dogs fed a standard diet without RAP (Control group), dogs fed a high-fat diet without RAP (Obese group), or dogs fed a standard diet with RAP (RAP group). All underwent electrophysiology study, and hearts were excised for histopathologic and fibrosis-related gene expression analyses. RESULTS: Left atrial (LA) pressure was significantly higher in the Obese group than in the Control, RAP, and Obese-RAP groups (23.4 ± 6.9 vs. 11.4 ± 2.1, 11.9 ± 6.4, and 13.5 ± 2.9 mmHg; p = .005). The effective refractory period of the inferior PV was significantly shorter in the RAP and Obese-RAP groups than in the Control group (p = .043). Short-duration AF was induced at greatest frequency in the Obese-RAP and Obese groups (p < .05). Epicardial fat/Fatty infiltration was greatest in the Obese-RAP group, and greater in the Obese and RAP groups than in the Control group. %interstitial fibrosis/fibrosis-related gene expression was significantly greater in the Obese-RAP and RAP groups (p < .05). CONCLUSIONS: Vulnerability to AF was associated with increased LA pressure and increased epicardial fat/fatty infiltration in our Obese group, and with increased epicardial fat/fibrofatty infiltration in the RAP and Obese-RAP groups. These may explain the role of obesity/epicardial fat in the pathogenesis of AF.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Tejido Adiposo , Animales , Fibrilación Atrial/etiología , Modelos Animales de Enfermedad , Perros , Atrios Cardíacos , Obesidad/complicaciones , Pericardio
15.
Pacing Clin Electrophysiol ; 44(4): 693-702, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33595100

RESUMEN

BACKGROUND: A novel steerable sheath visualized on a three-dimensional mapping system has become available in this era in which a durable pulmonary vein (PV) isolation (PVI) with reduced fluoroscopy is required. METHODS: In 60 patients who underwent a PVI with a visualized sheath (n = 30) and non-visualized conventional sheath (n = 30), the fluoroscopic time and catheter stability during the PVI were analyzed. RESULTS: The fluoroscopic time during the transseptal access (0 [0, 0.1] vs. 1.4 [0.8, 2.3] minutes, P < .001) and PVI (0 [0, 0.1] vs. 0.4 [0.2, 1.1] minutes, P < .001) were shorter in the visualized sheath group than conventional sheath group. The procedure time during the PVI (32.0 [26.8, 36.3] vs. 41.0 [31.8, 47.3] minutes, P = .01), particularly during the right PVI (15.0 [12.8, 18.0] vs. 23.0 [15.8, 26.3] minutes, P = .009), was shorter in the visualized sheath group than conventional sheath group, however, that during the other steps was equivalent. The standard deviation of the catheter contact force during each radiofrequency application was smaller in the visualized sheath group than conventional sheath group (4.5 ± 2.7 vs. 4.9 ± 3.1 g, P = .001). The impedance drop for each lesion was larger in the visualized sheath group than conventional sheath group (10.7 ± 6.5 vs. 9.8 ± 5.5 ohms, P < .001). The incidence of acute PV reconnections per patient (30% vs. 23%, P = .56) and per PV segment (2.5% vs. 2.3%, P = .83) were similar between the two groups. No major complications occurred in either sheath group. CONCLUSIONS: The use of visualized sheaths may reduce the fluoroscopic time and improve the catheter stability during the PVI.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Imagenología Tridimensional , Venas Pulmonares/cirugía , Ultrasonografía Intervencional , Anciano , Fibrilación Atrial/diagnóstico por imagen , Mapeo Epicárdico , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Factores de Tiempo
16.
J Cardiovasc Electrophysiol ; 31(9): 2310-2318, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32613693

RESUMEN

INTRODUCTION: The clinical efficacy and safety of hot balloon ablation (HBA) for the treatment of persistent AF (PerAF) remain unclear. We aimed to evaluate the clinical efficacy and safety of HBA versus cryoballoon ablation (CBA) as a treatment for PerAF. METHODS: Of 195 consecutive patients who underwent initial catheter ablation for PerAF (AF lasting for longer than 7 days but shorter than 12 months), 158 propensity score-matched (79 HBA and 79 CBA) patients were included in our retrospective study. All patients who underwent HBA received applications of energy to the upper posterior LA wall with a larger balloon in addition to single shots to each pulmonary vein (PV) ostium, whereas those who underwent CBA received simple single-shot applications. The electrically isolated surface area (ISA), including the PV antrum and part of the posterior LA wall, was assessed by high-resolution mapping. RESULTS: The success of the PV isolation with balloon shots alone did not differ between HBA and CBA (81% vs. 85%; p = .52). The ISA was generally wide in both groups and significantly larger in the HBA group than in the CBA group (61 ± 16% vs. 51 ± 12%; p < .001). The incidence of procedure-related complications did not differ significantly (HBA 4% vs. CBA 1%; p = .62) nor did the arrhythmia recurrence rate (HBA 11% vs. CBA 18% at 18 months; p = .26). CONCLUSION: Despite the difference in protocols, HBA and CBA performed for PerAF appear comparable in terms of wide antral lesion creation, clinical efficacy, and safety. Further prospective studies, based on a unified methodology, are needed.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Humanos , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
17.
Pacing Clin Electrophysiol ; 43(2): 201-209, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31883132

RESUMEN

BACKGROUND: Large pulmonary veins (PVs) have the risk of excessive cooling when the cryoballoon is moved into them, whereas smaller PVs may not be isolated because of insufficient balloon-tissue contact. We previously reported that the effective nadir balloon temperature (NBT) was <- 44°C for predicting early PV reconnections. However, the ideal PV and left atrial (LA) diameters for cooling temperatures during cryoballoon ablation (CBA) are unknown. METHODS: We measured the PV ostium (PVos) and LA diameters on computed tomography images in 71 atrial fibrillation patients who underwent a 28-mm CBA. We defined -60°C ≤ NBT <- 44°C as the optimal NBT. The optimal PVos diameters and elliptical area were determined using the receiver operating characteristic curve cutoff values for the optimal NBT. RESULTS: The maximum PVos diameter (PVmax), minimum PVos diameter (PVmin), and PV elliptical area correlated negatively with the NBT (PVmax: r = -.34, P < .0001; PVmin: r = -.41, P < .0001; PV elliptical area: r = -.41, P < .0001). Based on the NBT-derived definition, the optimal PVmax, PVmin, and PV elliptical area were 19 < PVmax ≤ 21 mm, 14 < PVmin ≤ 16 mm, and 186.83 < PV elliptical area ≤ 254.34 mm2 , respectively. In addition, a positive correlation between the LA longitudinal diameter and NBT was observed in the right superior PV (r = .34, P = .004), and the LA transverse diameter correlated inversely with the NBT in the left inferior PV (r = -.34, P = .004). CONCLUSIONS: We identified the optimal PV diameters and elliptical area to establish the optimal NBT during the second-generation 28-mm CBA. These data will help for the preclinical judgment for a successful CBA.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Venas Pulmonares/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X
18.
J Cardiovasc Electrophysiol ; 30(8): 1261-1269, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31111558

RESUMEN

INTRODUCTION: Although electrophysiologic and anatomic factors associated with the need for touch-up radiofrequency (RF) applications after cryoballoon ablation (CBA) for atrial fibrillation (AF) have been well described, those associated with the need for such touch-up after hot balloon ablation (HBA) have not. We aimed to identify factors predictive of the need for touch-up applications following HBA. METHODS: Anatomic and electrophysiologic factors predictive of the need for touch-up RF ablation were compared between 46 propensity score-matched pairs of patients who underwent HBA or CBA for AF. RESULTS: Touch-up RF ablation was more frequently required after HBA than after CBA (57% vs 30%, respectively; P = .01), and mostly at the anterior aspect of the left superior pulmonary vein (LSPV) carina after HBA (35%) but at the inferior aspect of the right inferior PV (RIPV) after CBA (71%). Post HBA touch-up was associated with male gender, a CHA 2 DS 2 -VASc score ≤ 2, PV-left atrial bipolar voltage ≥ 1.35 mV, and PV trunk length ≥ 24.0 mm; post CBA touch-up associated with a history of heart failure. CONCLUSION: Following balloon ablation for AF, there may be a need for touch-up applications, especially at the LSPV ridge after HBA but at the RIPV after CBA. It may behoove operators to expect a need for touch-up following HBA when patients are male, have a CHA2 DS 2 -VASc score ≤ 2 points, when PV-LA bipolar voltage is ≥ 1.35 mV, or when the PV trunk is ≥ 24.0 mm or following CBA when there is a history of heart failure.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
19.
Int Heart J ; 60(4): 812-821, 2019 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-31308323

RESUMEN

Pulmonary vein isolation (PVI) of atrial fibrillation (AF) can reduce the AF burden and, potentially, reduce the long-term risk of strokes and death. However, it remains unclear whether anticoagulants can be stopped after PVI because of post-ablation AF recurrence in some patients. This study aimed to investigate the discontinuation rate of anticoagulants and long-term incidence of strokes after PVI.We enrolled 512 consecutive Japanese patients with AF (mean age, 63.4 ± 10.4 years; 123 women; 234 with non-paroxysmal AF; CHADS2 score/CHA2DS2-VASC score, 1.32 ± 1.12/2.21 ± 1.54) who underwent PVI between 2012 and 2015. During a 28.0 ± 17.1 -month follow-up, anticoagulants were terminated in 230 (44.9%) of the 512 patients, AF recurred in 200 (39.1%), and 10 (1.95%) suffered from a stroke. Death occurred in 5 (0.98%) patients. Although the incidence of strokes, by a Kaplan-Meier analysis, was similar, the incidence of death was lower (Hazard ratio 0.37, 95% confidence interval 0.12-0.93, P = 0.041) in the AF ablation group than the control group without ablation after 1:1 propensity score matching (the control data was derived from 2,986 patients in the SAKURA AF Registry, a large-cohort AF registry).Anticoagulants were discontinued in nearly half the patients who underwent AF ablation; of these, 39.1% experienced AF recurrences, 1.95% suffered from strokes, and 0.98% died, but the risk of death after AF ablation appeared to be lower than that in a propensity score-matched control group without ablation during long-term follow-up.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Electrocardiografía , Complicaciones Posoperatorias/epidemiología , Medición de Riesgo/métodos , Anciano , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA