Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Br J Sports Med ; 41(7): 460-1, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17224439

RESUMEN

The case of a 24-year-old female professional, long-distance runner who presented with acute proximal posterior thigh pain is reported. History and clinical findings were consistent with acute hamstring strain but MRI demonstrated circumflex femoral vein thrombosis. This is the first case of proximal posterior thigh pain caused by circumflex femoral vein thrombosis reported in the literature. Doctors dealing with sports injuries should be aware of this clinical entity that mimics hamstring strain.


Asunto(s)
Carrera/lesiones , Esguinces y Distensiones/diagnóstico , Muslo/irrigación sanguínea , Trombosis de la Vena/diagnóstico , Adulto , Diagnóstico Diferencial , Femenino , Vena Femoral , Humanos , Imagen por Resonancia Magnética , Músculo Esquelético/lesiones , Dolor/etiología
2.
Arthroscopy ; 23(11): 1247.e1-3, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17986419

RESUMEN

The RigidFix Cross Pin System (DePuy Mitek, Raynham, MA) is a popular technique for femoral fixation of graft in ACL reconstruction. In some cases, though, cross pins miss the femoral tunnel resulting in inadequate proximal graft fixation. We present a simple test to detect the incorrect placement of cross pins. The pinholes are drilled through the guide frame, leaving 2 sleeves for cross pins insertion. The manufacturer's recommendations, at this stage, are to reinsert the femoral tunnel guidewire, remove the guide frame, and insert the graft without verifying accurate pinhole positioning. We reinsert the femoral tunnel guidewire without removing the guide frame, and a second guidewire is introduced through each of the sleeves in turn. In case of appropriate pinhole placement, the 2 guidewires will meet in the cannulated rod of the guide frame and the surgeon will have the metal-to-metal feeling. If the pinhole misses the femoral tunnel, the 2 guidewires will not meet and the surgeon will not have the metal-to-metal feeling. In our practice, 9 cases of inaccurate pinhole placement were detected with this test and verified by direct vision of the femoral tunnel with the arthroscope. We find this test simple, reliable, and not time consuming.


Asunto(s)
Ligamento Cruzado Anterior/cirugía , Artroscopía/métodos , Clavos Ortopédicos , Fémur/cirugía , Lesiones del Ligamento Cruzado Anterior , Plastía con Hueso-Tendón Rotuliano-Hueso , Humanos , Procedimientos de Cirugía Plástica/instrumentación , Procedimientos de Cirugía Plástica/métodos , Instrumentos Quirúrgicos , Tibia/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA