Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 51(8): 2320-2331, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38453729

RESUMEN

PURPOSE: The recent development and approval of new diagnostic imaging and therapy approaches in the field of theranostics have revolutionised nuclear medicine practice. To ensure the provision of these new imaging and therapy approaches in a safe and high-quality manner, training of nuclear medicine physicians and qualified specialists is paramount. This is required for trainees who are learning theranostics practice, and for ensuring minimum standards for knowledge and competency in existing practising specialists. METHODS: To address the need for a training curriculum in theranostics that would be utilised at a global level, a Consultancy Meeting was held at the IAEA in May 2023, with participation by experts in radiopharmaceutical therapy and theranostics including representatives of major international organisations relevant to theranostics practice. RESULTS: Through extensive discussions and review of existing curriculum and guidelines, a harmonised training program for theranostics was developed, which aims to ensure safe and high quality theranostics practice in all countries. CONCLUSION: The guiding principles for theranostics training outlined in this paper have immediate relevance for the safe and effective practice of theranostics.


Asunto(s)
Medicina Nuclear , Humanos , Medicina Nuclear/educación , Nanomedicina Teranóstica , Curriculum
2.
Heart Lung Circ ; 33(3): 384-391, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38365497

RESUMEN

AIM: The aim of this study was to assess the recovery rates of diagnostic cardiac procedure volumes in the Oceania Region, midway through the coronavirus disease 2019 (COVID-19) pandemic. METHODS: A survey was performed comparing procedure volumes between March 2019 (pre-pandemic), April 2020 (during first wave of COVID-19 pandemic), and April 2021 (1 year into the COVID-19 pandemic). A total of 31 health care facilities within Oceania that perform cardiac diagnostic procedures were surveyed, including a mixture of metropolitan and regional, hospital and outpatient, public and private sites, as well as teaching and non-teaching hospitals. A comparison was made with 549 centres in 96 countries in the rest of the world (RoW) outside of Oceania. The total number and median percentage change in procedure volume were measured between the three timepoints, compared by test type and by facility. RESULTS: A total of 11,902 cardiac diagnostic procedures were performed in Oceania in April 2021 as compared with 11,835 pre-pandemic in March 2019 and 5,986 in April 2020; whereas, in the RoW, 499,079 procedures were performed in April 2021 compared with 497,615 pre-pandemic in March 2019 and 179,014 in April 2020. There was no significant difference in the median recovery rates for total procedure volumes between Oceania (-6%) and the RoW (-3%) (p=0.81). While there was no statistically significant difference in percentage recovery been functional ischaemia testing and anatomical coronary testing in Oceania as compared with the RoW, there was, however, a suggestion of poorer recovery in anatomical coronary testing in Oceania as compared with the RoW (CT coronary angiography -16% in Oceania vs -1% in RoW, and invasive coronary angiography -20% in Oceania vs -9% in RoW). There was no statistically significant difference in recovery rates in procedure volume between metropolitan vs regional (p=0.44), public vs private (p=0.92), hospital vs outpatient (p=0.79), or teaching vs non-teaching centres (p=0.73). CONCLUSIONS: Total cardiology procedure volumes in Oceania normalised 1 year post-pandemic compared to pre-pandemic levels, with no significant difference compared with the RoW and between the different types of health care facilities.


Asunto(s)
COVID-19 , Cardiología , Humanos , COVID-19/epidemiología , Pandemias , Encuestas y Cuestionarios , Angiografía Coronaria , Prueba de COVID-19
3.
Heart Lung Circ ; 30(10): 1477-1486, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34053885

RESUMEN

OBJECTIVES: The INCAPS COVID Oceania study aimed to assess the impact caused by the COVID-19 pandemic on cardiac procedure volume provided in the Oceania region. METHODS: A retrospective survey was performed comparing procedure volumes within March 2019 (pre-COVID-19) with April 2020 (during first wave of COVID-19 pandemic). Sixty-three (63) health care facilities within Oceania that perform cardiac diagnostic procedures were surveyed, including a mixture of metropolitan and regional, hospital and outpatient, public and private sites, and 846 facilities outside of Oceania. The percentage change in procedure volume was measured between March 2019 and April 2020, compared by test type and by facility. RESULTS: In Oceania, the total cardiac diagnostic procedure volume was reduced by 52.2% from March 2019 to April 2020, compared to a reduction of 75.9% seen in the rest of the world (p<0.001). Within Oceania sites, this reduction varied significantly between procedure types, but not between types of health care facility. All procedure types (other than stress cardiac magnetic resonance [CMR] and positron emission tomography [PET]) saw significant reductions in volume over this time period (p<0.001). In Oceania, transthoracic echocardiography (TTE) decreased by 51.6%, transoesophageal echocardiography (TOE) by 74.0%, and stress tests by 65% overall, which was more pronounced for stress electrocardiograph (ECG) (81.8%) and stress echocardiography (76.7%) compared to stress single-photon emission computerised tomography (SPECT) (44.3%). Invasive coronary angiography decreased by 36.7% in Oceania. CONCLUSION: A significant reduction in cardiac diagnostic procedure volume was seen across all facility types in Oceania and was likely a function of recommendations from cardiac societies and directives from government to minimise spread of COVID-19 amongst patients and staff. Longer term evaluation is important to assess for negative patient outcomes which may relate to deferral of usual models of care within cardiology.


Asunto(s)
COVID-19 , Cardiología , Humanos , Pandemias , Estudios Retrospectivos , SARS-CoV-2 , Tomografía Computarizada por Rayos X
4.
Eur Respir J ; 55(2)2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31831584

RESUMEN

BACKGROUND: A large proportion of the huge global burden of extrapulmonary tuberculosis (EPTB) cases are treated empirically without accurate definition of disease sites and extent of multi-organ disease involvement. Positron emission tomography (PET) imaging using 2-deoxy-2-(fluorine-18) fluoro-d-glucose (18F-FDG) in tuberculosis could be a useful imaging technique for localising disease sites and extent of disease. METHODS: We conducted a study of HIV-negative adult patients with a new clinical diagnosis of EPTB across eight centres located in six countries: India, Pakistan, Thailand, South Africa, Serbia and Bangladesh, to assess the extent of disease and common sites involved at first presentation. 18F-FDG PET/computed tomography (CT) scans were performed within 2 weeks of presentation. FINDINGS: 358 patients with EPTB (189 females; 169 males) were recruited over 45 months, with an age range of 18-83 years (females median 30 years; males median 38 years). 350 (98%) out of 358 patients (183 female, 167 male) had positive scans. 118 (33.7%) out of 350 had a single extrapulmonary site and 232 (66.3%) out of 350 had more than one site (organ) affected. Lymph nodes, skeleton, pleura and brain were common sites. 100 (28%) out of 358 EPTB patients had 18F-FDG PET/CT-positive sites in the lung. 110 patients were 18F-FDG PET/CT-positive in more body sites than were noted clinically at first presentation and 160 patients had the same number of positive body sites. INTERPRETATION: 18F-FDG PET/CT scan has potential for further elucidating the spectrum of disease, pathogenesis of EPTB and monitoring the effects of treatment on active lesions over time, and requires longitudinal cohort studies, twinned with biopsy and molecular studies.


Asunto(s)
Fluorodesoxiglucosa F18 , Tuberculosis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Bangladesh , Estudios Transversales , Femenino , Humanos , India , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Pakistán , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Radiofármacos , Sudáfrica , Tuberculosis/diagnóstico por imagen , Adulto Joven
5.
Eur J Nucl Med Mol Imaging ; 47(13): 3118-3129, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32483653

RESUMEN

BACKGROUND: Initial studies of tuberculosis (TB) in macaques and humans using 18F-FDG positron emission tomography (PET) imaging as a research tool suggest its usefulness in localising disease sites and as a clinical biomarker. Sequential serial scans in patients with extrapulmonary TB (EPTB) could inform on the value of PET-CT for monitoring response to treatment and defining cure. PATIENTS AND METHODS: HIV-negative adults with EPTB from eight sites across six countries had three 18F-FDG PET/CT scans: (i) within 2 weeks of enrolment, (ii) at 2 months into TB treatment and (iii) at end of ATT treatment. Scanning was performed according to the EANM guidelines. 18F-FDG PET/CT scans were performed 60 ± 10 min after intravenous injection of 2.5-5.0 MBq/kg of 18F-FDG. FINDINGS: One hundred and forty-seven patients with EPTB underwent 3 sequential scans. A progressive reduction over time of both the number of active sites and the uptake level (SUVmax) at these sites was seen. At the end of WHO recommended treatment, 53/147 (36.0%) patients had negative PET/CT scans, and 94/147 (63.9%) patients remained PET/CT positive, of which 12 patients had developed MDR TB. One died of brain tuberculoma. INTERPRETATION: Current 18F-FDG PET/CT imaging technology cannot be used clinically as a biomarker of treatment response, cure or for decision-making on when to stop EPTB treatment. PET/CT remains a research tool for TB and further development of PET/CT is required using new Mycobacterium tuberculosis-specific radiopharmaceuticals targeting high-density surface epitopes, gene targets or metabolic pathways.


Asunto(s)
Fluorodesoxiglucosa F18 , Tuberculosis , Adulto , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Radiofármacos , Tuberculosis/diagnóstico por imagen
6.
J Nucl Cardiol ; 27(2): 465-478, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-30168029

RESUMEN

BACKGROUND: Consistency of results between different readers is an important issue in medical imaging, as it affects portability of results between institutions and may affect patient care. The International Atomic Energy Agency (IAEA) in pursuing its mission of fostering peaceful applications of nuclear technologies has supported several training activities in the field of nuclear cardiology (NC) and SPECT myocardial perfusion imaging (MPI) in particular. The aim of this study was to verify the outcome of those activities through an international clinical audit on MPI where participants were requested to report on studies distributed from a core lab. METHODS: The study was run in two phases: in phase 1, SPECT MPI studies were distributed as raw data and full processing was requested as per local practice. In phase 2, images from studies pre-processed at the core lab were distributed. Data to be reported included summed stress score (SSS); summed rest score (SRS); summed difference score (SDS); left ventricular (LV) ejection fraction (EF) and end- diastolic volume (EDV). Qualitative appraisals included the assessment of perfusion and presence of ischemia, scar or mixed patterns, presence of transient ischemic dilation (TID), and risk for cardiac events (CE). Twenty-four previous trainees from low- and middle-income countries participated (core participants group) and their results were assessed for inter-observer variability in each of the two phases, and for changes between phases. The same evaluations were performed for a group of eleven international experts (experts group). Results were also compared between the groups. RESULTS: Expert readers showed an excellent level of agreement for all parameters in both phase 1 and 2. For core participants, the concordance of all parameters in phase 1 was rated as good to excellent. Two parameters which were re-evaluated in phase 2, namely SSS and SRS, showed an increased level of concordance, up to excellent in both cases. Reporting of categorical variables by expert readers remained almost unchanged between the two phases, while core participants showed an increase in phase 2. Finally, pooled LVEF values did not show a significant difference between core participants and experts. However, significant differences were found between LVEF values obtained using different software packages for cardiac analysis. CONCLUSIONS: In this study, inter-observer agreement was moderate-to-good for core group readers and good-to-excellent for expert readers. The quality of reporting is affected by the quality of processing. These results confirm the important role of the IAEA training activities in improving imaging in low- and middle-income countries.


Asunto(s)
Imagen de Perfusión Miocárdica/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca , Países en Desarrollo , Prueba de Esfuerzo , Femenino , Geografía , Corazón , Ventrículos Cardíacos , Humanos , Cooperación Internacional , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Variaciones Dependientes del Observador , Tomografía de Emisión de Positrones/métodos , Pobreza , Riesgo , Volumen Sistólico , Tecnecio , Tomografía Computarizada de Emisión de Fotón Único/normas , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda
9.
J Nucl Cardiol ; 24(3): 851-859, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-26902484

RESUMEN

BACKGROUND: Comparison of Latin American (LA) nuclear cardiology (NC) practice with that in the rest of the world (RoW) will identify areas for improvement and lead to educational activities to reduce radiation exposure from NC. METHODS AND RESULTS: INCAPS collected data on all SPECT and PET procedures performed during a single week in March-April 2013 in 36 laboratories in 10 LA countries (n = 1139), and 272 laboratories in 55 countries in RoW (n = 6772). Eight "best practices" were identified a priori and a radiation-related Quality Index (QI) was devised indicating the number used. Mean radiation effective dose (ED) in LA was higher than in RoW (11.8 vs 9.1 mSv, p < 0.001). Within a populous country like Brazil, a wide variation in laboratory mean ED was found, ranging from 8.4 to 17.8 mSv. Only 11% of LA laboratories achieved median ED <9 mSv, compared to 32% in RoW (p < 0.001). QIs ranged from 2 in a laboratory in Mexico to 7 in a laboratory in Cuba. Three major opportunities to reduce ED for LA patients were identified: (1) more laboratories could implement stress-only imaging, (2) camera-based methods of ED reduction, including prone imaging, could be more frequently used, and (3) injected activity of 99mTc could be adjusted reflecting patient weight/habitus. CONCLUSIONS: On average, radiation dose from NC is higher in LA compared to RoW, with median laboratory ED <9 mSv achieved only one third as frequently as in RoW. Opportunities to reduce radiation exposure in LA have been identified and guideline-based recommendations made to optimize protocols and adhere to the "as low as reasonably achievable" (ALARA) principle.


Asunto(s)
Cardiología/normas , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Garantía de la Calidad de Atención de Salud/estadística & datos numéricos , Exposición a la Radiación/prevención & control , Protección Radiológica/estadística & datos numéricos , Tomografía Computarizada de Emisión/estadística & datos numéricos , Cardiología/estadística & datos numéricos , Adhesión a Directriz/normas , Adhesión a Directriz/estadística & datos numéricos , Encuestas de Atención de la Salud , Humanos , Internacionalidad , América Latina/epidemiología , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Pautas de la Práctica en Medicina/normas , Mejoramiento de la Calidad , Protección Radiológica/normas , Tomografía Computarizada de Emisión/normas , Revisión de Utilización de Recursos
10.
Circ J ; 81(4): 501-510, 2017 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-28179594

RESUMEN

BACKGROUND: This paper examines the current status of radiation exposure to patients in myocardial perfusion imaging (MPI) in Asia.Methods and Results:Laboratories voluntarily provided information on MPI performed over a 1-week period. Eight best practice criteria regarding MPI were predefined by an expert panel. Implementation of ≥6 best practices (quality index [QI] ≥6) was pre-specified as a desirable goal for keeping radiation exposure at a low level. Radiation effective dose (ED) in 1,469 patients and QI of 69 laboratories in Asia were compared against data from 239 laboratories in the rest of the world (RoW). Mean ED was significantly higher in Asia (11.4 vs. 9.6 mSv; P<0.0001), with significantly lower doses in South-East vs. East Asia (9.7 vs. 12.7 mSv; P<0.0001). QI in Asia was lower than in RoW. In comparison with RoW, Asian laboratories used thallium more frequently, used weight-based technetium dosing less frequently, and trended towards a lower rate of stress-only imaging. CONCLUSIONS: MPI radiation dose in Asia is higher than that in the RoW and linked to less consistent use of laboratory best practices such as avoidance of thallium, weight-based dosing, and use of stress-only imaging. Given that MPI is performed in Asia within a diverse array of medical contexts, laboratory-specific adoption of best practices offers numerous opportunities to improve quality of care.


Asunto(s)
Imagen de Perfusión Miocárdica/efectos adversos , Pautas de la Práctica en Medicina/normas , Exposición a la Radiación/estadística & datos numéricos , Anciano , Asia , Cardiología/métodos , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medicina Nuclear/métodos , Calidad de la Atención de Salud , Dosis de Radiación , Tecnecio/administración & dosificación , Talio/administración & dosificación
11.
Heart Lung Circ ; 26(1): 25-34, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27425184

RESUMEN

BACKGROUND: There is concern about radiation exposure with radionuclide myocardial perfusion imaging (MPI). This sub-study of the International Atomic Energy Agency (IAEA) Nuclear Cardiology Protocols Study reports radiation doses from MPI, and use of dose-optimisation protocols in Australia and New Zealand (ANZ), and compares them with data from the rest of the world. METHODS: Data were collected from 7911 MPI studies performed in 308 laboratories worldwide in one week in 2013, including 439 MPI studies from 34 ANZ laboratories. For each laboratory, effective radiation dose (ED) and a quality index (QI) score (out of 8) based on pre-specified "best practices" was determined. RESULTS: In ANZ patients, ED ranged from 0.9-17.9 milliSievert (mSv). Median ED was similar in ANZ compared with the rest of the world (10.0 (IQR: 6.5-11.7) vs. 10.0 (IQR 6.4-12.6, P=0.15), as were mean QI scores (5.5±0.7 vs. 5.4±1.3, P=0.84). Use of stress-only imaging (17.6% vs. 31.8% of labs, P=0.09) and weight-based dosing of technetium-99m (14.7% vs. 30.3%, P=0.07) was lower in ANZ compared with the rest of the world but this difference was not statistically significant. Median ED was significantly lower in metropolitan versus non-metropolitan laboratories (10.1 mSv vs. 11.6 mSv, P<0.01), although mean QI scores were similar (5.4±0.8 vs. 5.5±0.7, P=0.75). CONCLUSION: Across ANZ, there is variability in ED from MPI, and use of radiation safety practices, particularly between metropolitan and non-metropolitan laboratories. Overall, ANZ laboratories have a similar median ED to laboratories in the rest of the world.


Asunto(s)
Imagen de Perfusión Miocárdica/efectos adversos , Dosis de Radiación , Exposición a la Radiación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oceanía
12.
Eur J Nucl Med Mol Imaging ; 43(4): 718-28, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26686336

RESUMEN

PURPOSE: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. METHODS: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). RESULTS: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. CONCLUSION: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Tomografía de Emisión de Positrones/métodos , Guías de Práctica Clínica como Asunto , Dosis de Radiación , Técnicas de Imagen Cardíaca/efectos adversos , Técnicas de Imagen Cardíaca/instrumentación , Técnicas de Imagen Cardíaca/normas , Cardiología/organización & administración , Unión Europea , Medicina Nuclear/organización & administración , Tomografía de Emisión de Positrones/efectos adversos , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/normas , Sociedades Científicas
13.
Eur Heart J ; 36(26): 1689-96, 2015 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-25898845

RESUMEN

AIMS: To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. METHODS AND RESULTS: We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. CONCLUSION: Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally.


Asunto(s)
Adhesión a Directriz/normas , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Guías de Práctica Clínica como Asunto/normas , Dosis de Radiación , Exposición a la Radiación/análisis , Anciano , Cardiología/normas , Protocolos Clínicos/normas , Estudios Transversales , Femenino , Salud Global , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Tomografía de Emisión de Positrones/normas , Tomografía de Emisión de Positrones/estadística & datos numéricos , Práctica Profesional/normas , Práctica Profesional/estadística & datos numéricos , Calidad de la Atención de Salud/normas , Calidad de la Atención de Salud/estadística & datos numéricos , Análisis de Regresión , Tomografía Computarizada de Emisión de Fotón Único/normas , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos
14.
Life (Basel) ; 14(1)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38276287

RESUMEN

Pediatric Differentiated Thyroid Cancer (pedDTC) is a rare pediatric malignancy with an increasing incidence over time. To date, there is a paucity of literature specifically addressing pedDTC within the context of Middle Eastern ethnicity. This retrospective study aimed to assess the risk-stratifying factors for overall survival (OS) and event-free survival (EFS) in pediatric DTC patients from Iraq and Jordan. The medical records of 81 patients from two tertiary cancer institutes were retrieved. Kaplan-Meier analysis was employed to investigate OS and EFS, and the Cox proportional hazards model was employed to estimate hazard ratios. All patients underwent surgery and radioactive iodine therapy, with a median age of 14 and an interquartile range of 12-15. Lymph node involvement was observed in 55% of cases, while distant metastases were present in 13.5%. After a median follow-up period of 68 months, the 10-year survival rate was determined to be 94%, while the 10-year EFS rate was 58%. EFS was negatively impacted by cervical lymph node metastases and early age of diagnosis (p ≤ 0.01, each). Therefore, pediatrics with initial cervical lymph node metastases and those diagnosed before puberty tend to experience poorer EFS, which may justify the need for more aggressive management plans.

15.
Am J Cardiol ; 214: 85-93, 2024 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-38218393

RESUMEN

The COVID-19 pandemic disrupted the delivery of cardiovascular care, including noninvasive testing protocols and test selection for the evaluation of coronary artery disease (CAD). Trends in test selection in traditional versus advanced noninvasive tests for CAD during the pandemic and in countries of varying income status have not been well studied. The International Atomic Energy Agency conducted a global survey to assess the pandemic-related changes in the practice of cardiovascular diagnostic testing. Site procedural volumes for noninvasive tests to evaluate CAD from March 2019 (prepandemic), April 2020 (onset), and April 2021 (initial recovery) were collected. We considered traditional testing modalities, such as exercise electrocardiography, stress echocardiography, and stress single-photon emission computed tomography, and advanced testing modalities, such as stress cardiac magnetic resonance, coronary computed tomography angiography, and stress positron emission tomography. Survey data were obtained from 669 centers in 107 countries, reporting the performance of 367,933 studies for CAD during the study period. Compared with 2019, traditional tests were performed 14% less frequently (recovery rate 82%) in 2021 versus advanced tests, which were performed 15% more frequently (128% recovery rate). Coronary computed tomography angiography, stress cardiac magnetic resonance, and stress positron emission tomography showed 14%, 25%, and 25% increases in volumes from 2019 to 2021, respectively. The increase in advanced testing was isolated to high- and upper middle-income countries, with 132% recovery in advanced tests by 2021 compared with 55% in lower income nations. The COVID-19 pandemic exacerbated economic disparities in CAD testing practice between wealthy and poorer countries. Greater recovery rates and even new growth were observed for advanced imaging modalities; however, this growth was restricted to wealthy countries. Efforts to reduce practice variations in CAD testing because of economic status are warranted.


Asunto(s)
COVID-19 , Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/epidemiología , Angiografía Coronaria/métodos , Pandemias , COVID-19/epidemiología , Tomografía Computarizada de Emisión de Fotón Único/métodos , Prueba de Esfuerzo
16.
Int J Cardiol Heart Vasc ; 52: 101404, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38590383

RESUMEN

Background: The COVID-19 pandemic disproportionately impacted Latin America (LATAM), significantly disrupting cardiovascular testing. This study evaluated cardiac procedure recovery in LATAM one year after the outbreak. Methods: The International Atomic Energy Agency (IAEA) surveyed 669 centers in 107 countries worldwide, including 135 facilities in 19 LATAM countries, to assess cardiovascular procedure volumes in March 2019, April 2020, and April 2021, and changes in center practices and staffing conditions one year into the COVID-19 pandemic. Findings: LATAM centers reported a 21 % decrease in procedure volumes in April 2021 from pre-pandemic-baseline, vs. a 0 % change in the rest of the world (RoW), and greater volume reductions for almost all procedure types. Centers in Central America and Mexico reported the largest procedure reductions (47 % reduction) compared to the Caribbean (15 %), and South America (14 %, p = 0.01), and this LATAM region was a significant predictor of lower procedure recovery in multivariable regression. More LATAM centers reported reduced salaries and increased layoffs of clinical staff compared to RoW, and LATAM respondents estimated that half of physician and non-physician staff experienced excess psychological stress related to the pandemic, compared to 25 % and 30 % in RoW (p < 0.001). Conclusions: Cardiovascular testing recovery in LATAM trailed behind RoW for most procedure types, with centers in Central America and Mexico reporting the greatest volume reductions. This study found lasting impacts of COVID-19 on cardiovascular care in LATAM and the need for mental health support for LATAM healthcare workers in current and future pandemics.

17.
Can Assoc Radiol J ; 64(1): 2-5, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22560564

RESUMEN

Global health has been an issue of seemingly low political importance in comparison with issues that have direct bearing on countries' national security. Recently, health has experienced a "political revolution" or a rise in political importance. Today, we face substantial global health challenges, from the spread of infectious disease, gaps in basic maternal and child health care, to the globalization of cancer. A recent estimate states that the "overall lifetime risk of developing cancer (both sexes) is expected to rise from more than one in three to one in two by 2015." These issues pose significant threats to international health security. To successfully combat these grave challenges, the international community must embrace and engage in global health diplomacy, defined by scholars Thomas Novotny and Vicanne Adams as a political activity aimed at improving global health, while at the same time maintaining and strengthening international relations. The IAEA (International Atomic Energy Agency) is an international organization with a unique mandate to "accelerate and enlarge the contribution of atomic energy to peace, health, and prosperity throughout the world." This article discusses global health diplomacy, reviews the IAEA's program activities in human health by focusing on radiation medicine and cancer, and the peaceful applications of atomic energy within the context of global health diplomacy.


Asunto(s)
Salud Global , Promoción de la Salud , Agencias Internacionales , Neoplasias/radioterapia , Energía Nuclear , Medicina Nuclear/educación , Protección Radiológica/normas , Humanos , Objetivos Organizacionales , Política , Radiometría , Transferencia de Tecnología
18.
Radiol Cardiothorac Imaging ; 5(5): e220288, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37908554

RESUMEN

Purpose: To characterize the recovery of diagnostic cardiovascular procedure volumes in U.S. and non-U.S. facilities in the year following the initial COVID-19 outbreak. Materials and Methods: The International Atomic Energy Agency (IAEA) coordinated a worldwide study called the IAEA Noninvasive Cardiology Protocols Study of COVID-19 2 (INCAPS COVID 2), collecting data from 669 facilities in 107 countries, including 93 facilities in 34 U.S. states, to determine the impact of the pandemic on diagnostic cardiovascular procedure volumes. Participants reported volumes for each diagnostic imaging modality used at their facility for March 2019 (baseline), April 2020, and April 2021. This secondary analysis of INCAPS COVID 2 evaluated differences in changes in procedure volume between U.S. and non-U.S. facilities and among U.S. regions. Factors associated with return to prepandemic volumes in the United States were also analyzed in a multivariable regression analysis. Results: Reduction in procedure volumes in April 2020 compared with baseline was similar for U.S. and non-U.S. facilities (-66% vs -71%, P = .27). U.S. facilities reported greater return to baseline in April 2021 than did all non-U.S. facilities (4% vs -6%, P = .008), but there was no evidence of a difference when comparing U.S. facilities with non-U.S. high-income country (NUHIC) facilities (4% vs 0%, P = .18). U.S. regional differences in return to baseline were observed between the Midwest (11%), Northeast (9%), South (1%), and West (-7%, P = .03), but no studied factors were significant predictors of 2021 change from prepandemic baseline. Conclusion: The reductions in cardiac testing during the early pandemic have recovered within a year to prepandemic baselines in the United States and NUHICs, while procedure volumes remain depressed in lower-income countries.Keywords: SPECT, Cardiac, Epidemiology, Angiography, CT Angiography, CT, Echocardiography, SPECT/CT, MR Imaging, Radionuclide Studies, COVID-19, Cardiovascular Imaging, Diagnostic Cardiovascular Procedure, Cardiovascular Disease, Cardiac Testing Supplemental material is available for this article. © RSNA, 2023.

19.
Semin Nucl Med ; 52(1): 25-30, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34275594

RESUMEN

Coronavirus disease 2019 (COVID-19) was first detected in China in late 2019 and rapidly spread to nearby Asian countries in early 2020. Outbreaks occurred differently in each country and affected nuclear medicine (NM) practice significantly even before the COVID-19 pandemic. The Asian NM community has worked together from the beginning of the pandemic. Fortunately, the Asian Regional Cooperative Council for Nuclear Medicine annual general meeting and Asia Nuclear Medicine Board examination was held in Manila from January 28 to February 2, 2020; these were the last face-to-face events of these organizations to date. Members shared information about COVID-19 at the conference, and through online means afterwards. Web-based surveys performed from March to April 2020 for the Asian Regional Cooperative Council for Nuclear Medicine and Asia Nuclear Medicine Board communities showed a significant reduction of NM practice and supply of radioisotopes (RI) at the beginning of the COVID-19 pandemic. A follow-up survey in March to April 2021 clearly showed the recovery of both NM practice and RI supplies. The pattern of recovery is variable according to institutions and countries. Herein, we have reported the case-in-point operational histories of four representative institutions in the East, Southeast, South, and West Asia. The second outbreak in India is ongoing on a worrisome scale. Various communications and educational sessions were actively performed online in the Asian NM community during the pandemic.


Asunto(s)
COVID-19 , Medicina Nuclear , Asia/epidemiología , Humanos , Pandemias , Filipinas , SARS-CoV-2
20.
J Nucl Med Technol ; 50(3): 256-262, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35440476

RESUMEN

18F-FDG PET/CT quantification of whole-body tumor burden in lymphoma is not routinely performed because of the lack of fast methods. Although the semiautomatic method is fast, it is not fast enough to quantify tumor burden in daily clinical practice. Our purpose was to evaluate the performance of convolutional neural network (CNN) software in localizing neoplastic lesions in whole-body 18F-FDG PET/CT images of pediatric lymphoma patients. Methods: The retrospective image dataset, derived from the data pool of the International Atomic Energy Agency (coordinated research project E12017), included 102 baseline staging 18F-FDG PET/CT studies of pediatric lymphoma patients (mean age, 11 y). The images were quantified to determine the whole-body tumor burden (whole-body metabolic tumor volume [wbMTV] and whole-body total lesion glycolysis [wbTLG]) using semiautomatic software and CNN-based software. Both were displayed as semiautomatic wbMTV and wbTLG and as CNN wbMTV and wbTLG. The intraclass correlation coefficient (ICC) was applied to evaluate concordance between the CNN-based software and the semiautomatic software. Results: Twenty-six patients were excluded from the analysis because the software was unable to perform calculations for them. In the remaining 76 patients, CNN and semiautomatic wbMTV tumor burden metrics correlated strongly (ICC, 0.993; 95% CI, 0.989 - 0.996; P < 0.0001), as did CNN and semiautomatic wbTLG (ICC, 0.999; 95% CI, 0.998-0.999; P < 0.0001). However, the time spent calculating these metrics was significantly (<0.0001) less by CNN (mean, 19 s; range, 11-50 s) than by the semiautomatic method (mean, 21.6 min; range, 3.2-62.1 min), especially in patients with advanced disease. Conclusion: Determining whole-body tumor burden in pediatric lymphoma patients using CNN is fast and feasible in clinical practice.


Asunto(s)
Fluorodesoxiglucosa F18 , Linfoma , Niño , Fluorodesoxiglucosa F18/metabolismo , Humanos , Linfoma/diagnóstico por imagen , Redes Neurales de la Computación , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Estudios Retrospectivos , Carga Tumoral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA