Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 43(29): 2770-2780, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35695691

RESUMEN

AIM: Fatality of infective endocarditis (IE) is high worldwide, and its diagnosis remains a challenge. The objective of the present study was to compare the clinical characteristics and outcomes of patients with culture-positive (CPIE) vs. culture-negative IE (CNIE). METHODS AND RESULTS: This was an ancillary analysis of the ESC-EORP EURO-ENDO registry. Overall, 3113 patients who were diagnosed with IE during the study period were included in the present study. Of these, 2590 (83.2%) had CPIE, whereas 523 (16.8%) had CNIE. As many as 1488 (48.1%) patients underwent cardiac surgery during the index hospitalization, 1259 (48.8%) with CPIE and 229 (44.5%) with CNIE. The CNIE was a predictor of 1-year mortality [hazard ratio (HR) 1.28, 95% confidence interval (CI) 1.04-1.56], whereas surgery was significantly associated with survival (HR 0.49, 95% CI 0.41-0.58). The 1-year mortality was significantly higher in CNIE than CPIE patients in the medical subgroup, but it was not significantly different in CNIE vs. CPIE patients who underwent surgery. CONCLUSION: The present analysis of the EURO-ENDO registry confirms a higher long-term mortality in patients with CNIE compared with patients with CPIE. This difference was present in patients receiving medical therapy alone and not in those who underwent surgery, with surgery being associated with reduced mortality. Additional efforts are required both to improve the aetiological diagnosis of IE and identify CNIE cases early before progressive disease potentially contraindicates surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Endocarditis Bacteriana , Endocarditis , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Endocarditis/diagnóstico , Endocarditis/epidemiología , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/terapia , Humanos , Modelos de Riesgos Proporcionales , Sistema de Registros , Estudios Retrospectivos
2.
Infection ; 50(5): 1191-1202, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35290614

RESUMEN

PURPOSE: High mortality and a limited performance of valvular surgery are typical features of infective endocarditis (IE) in octogenarians, even though surgical treatment is a major determinant of a successful outcome in IE. METHODS: Data from the prospective multicentre ESC EORP EURO-ENDO registry were used to assess the prognostic role of valvular surgery depending on age. RESULTS: As compared to < 80 yo patients, ≥ 80 yo had lower rates of theoretical indication for valvular surgery (49.1% vs. 60.3%, p < 0.001), of surgery performed (37.0% vs. 75.5%, p < 0.001), and a higher in-hospital (25.9% vs. 15.8%, p < 0.001) and 1-year mortality (41.3% vs. 22.2%, p < 0.001). By multivariable analysis, age per se was not predictive of 1-year mortality, but lack of surgical procedures when indicated was strongly predictive (HR 2.98 [2.43-3.66]). By propensity analysis, 304 ≥ 80 yo were matched to 608 < 80 yo patients. Propensity analysis confirmed the lower rate of indication for valvular surgery (51.3% vs. 57.2%, p = 0.031) and of surgery performed (35.3% vs. 68.4%, p < 0.0001) in ≥ 80 yo. Overall mortality remained higher in ≥ 80 yo (in-hospital: HR 1.50[1.06-2.13], p = 0.0210; 1-yr: HR 1.58[1.21-2.05], p = 0.0006), but was not different from that of < 80 yo among those who had surgery (in-hospital: 19.7% vs. 20.0%, p = 0.4236; 1-year: 27.3% vs. 25.5%, p = 0.7176). CONCLUSION: Although mortality rates are consistently higher in ≥ 80 yo patients than in < 80 yo patients in the general population, mortality of surgery in ≥ 80 yo is similar to < 80 yo after matching patients. These results confirm the importance of a better recognition of surgical indication and of an increased performance of surgery in ≥ 80 yo patients.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Anciano de 80 o más Años , Endocarditis/epidemiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Mortalidad Hospitalaria , Humanos , Octogenarios , Estudios Prospectivos , Sistema de Registros
3.
Heart Vessels ; 37(9): 1526-1540, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35357543

RESUMEN

Cardiac amyloidosis (CAM), the most common cardiac storage disease is associated with significant changes in left-ventricular (LV) morphology and function. To gain particular insights into LV systolic longitudinal myocardial mechanics we investigated seven parameters derived by speckle-tracking-echocardiography (STE) in patients with confirmed CAM (n = 59). The results were compared with those of individuals with healthy heart (n = 150) and another primary myocardial disease with also thickened myocardium and severe diastolic and systolic LV-dysfunction (symptomatic LV-non-compaction-cardiomyopathy, LV-NC, n = 30). In addition to standard echocardiographical measures, the STE-derived data were evaluated and documented utilizing polar-diagrams to obtain overviews of longitudinal myocardial mechanics of the entire LV. Compared with healthy individuals, patients with CAM and LV-NC showed significantly reduced LV-ejection-fraction (EF), global longitudinal systolic peak-strain, strain-rate, and displacement. Pre-systolic stretch-index, post-systolic index, and the EF/global peak-longitudinal-strain-ratio (EF/S) were increased. In contrast to healthy-hearts and the LV-NC group only patients with CAM demonstrated significantly reduced time-to-peak systolic longitudinal strain and time-to-peak strain-rate. Although the level of the segmental values in longitudinal mechanics was significantly different between the groups, comparable intraventricular baso-apical parameter-gradients were found for systolic longitudinal peak-strain and strain-rate, pre-systolic-stretch-index, post-systolic-index, and peak systolic displacement. Compared to ATTR-amyloidosis (ATTR-CAM), patients with AL-amyloidosis (AL-CAM) demonstrated significantly lower end-diastolic and end-systolic LV-volumes, LV-mass-indices, relative apical strain, time-to-peak systolic longitudinal strain, and time-to-peak longitudinal strain-rate. CAM and LV-NC demonstrated altered myocardial mechanics with significantly different STE-derived echocardiographical parameters. ATTR-amyloidosis and AL-amyloidosis had at least significantly different time-to-peak strain, time-to-peak strain-rate and relative apical sparing values.


Asunto(s)
Amiloidosis , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas , Disfunción Ventricular Izquierda , Amiloidosis/diagnóstico por imagen , Ventrículos Cardíacos , Humanos , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/diagnóstico por imagen , Miocardio , Sístole , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda
4.
J Interv Cardiol ; 31(3): 384-390, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29490430

RESUMEN

OBJECTIVES: We present our single center experience with Medtronic CoreValve and Evolut R regarding procedural outcome and 3 years follow-up in patients with degenerated bioprostheses. METHODS: From 1645 patients who underwent transfemoral TAVI at our institution between February 2009 and December 2016, 37 patients with degenerated bioprosthesis were treated with Medtronic CoreValve/Evolut R. All data concerning baseline characteristic, procedural outcomes and follow-up were entered into a dedicated database. RESULTS: Mean age was 83.9 ± 4.4 years and patients showed an average logistic EuroSCORE of 33.2 ± 16.7%. Successful ViV deployment was achieved in all cases, a permanent pacemaker was implanted in 16.2%, no periinterventional stroke and no coronary obstruction occurred. Mortality at 30 days was 2.7%, at 1-year follow-up 5.7% and at three years 13.5%. Depending on bioprosthesis size <23 mm versus ≥23 mm echocardiographic mean gradients post implantation were significantly higher in the smaller bioprostheses, 22.8 mmHg ± 9.4 mmHg versus 15.1 ± 7.1, P = 0.013. CONCLUSION: ViV-TAVI with CoreValve/R is demonstrated to be safe and effective in terms of no coronary obstruction and very low mortality up to 3 years despite slightly higher mean transprosthetic gradients especially in very small bioprostheses.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios de Cohortes , Ecocardiografía , Femenino , Fluoroscopía , Humanos , Masculino , Marcapaso Artificial , Resultado del Tratamiento
5.
Echocardiography ; 35(5): 621-631, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29437242

RESUMEN

OBJECTIVES: Although procedure-related new cardiac conduction disturbances (CCDs) remain an important issue in transcatheter aortic valve implantation (TAVI), their effect on myocardial function and overall patient outcome remains unclear. The goal of this study was to analyze the influence of procedure-related CCDs on systolic and diastolic LV performance and on patient survival after TAVI. METHODS AND RESULTS: Ninety-five patients who underwent TAVI for severe symptomatic aortic stenosis (AS) and had a complete follow-up were evaluated with respect to procedure-related CCDs. Left ventricular (LV) performance was measured using standard echocardiographic parameters and speckle tracking analysis. Survival was assessed during longer-term follow-up (mean: 29.1 ± 16.9 months). After TAVI, the improvement of global LV function expressed as ejection fraction (LVEF; from 45.5 ± 10.0 to 47.8 ± 13.9%, P = .13) was not significant. New CCDs were found in 35.7% of TAVI recipients. A comparison between patients with and without new CCDs showed that LV systolic function improved in those without CCDs, while it tended to deteriorate in patients with CCDs (change in LVEF: 5.5 ± 12.3% vs -4.9% ± 11.5%, P = .001; change in global longitudinal strain (GLS): -1.1 ± 4.6% vs 1.2 ± 4.5%, P = .01). Changes in diastolic function did not differ significantly between the groups (changes in transmitral E/A-ratio: -0.3 ± 0.6 vs -0.5 ± 0.5, P = .1). Kaplan-Meier survival analysis revealed no significant differences between the two cohorts (P = .795). CONCLUSION: Procedure-related conduction abnormalities after TAVI lead to an LBBB-related dyssynchrony with impairment of LV performance but not of overall survival.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía/métodos , Prótesis Valvulares Cardíacas , Contracción Miocárdica/fisiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Función Ventricular Izquierda/fisiología , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Diástole , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Sístole , Resultado del Tratamiento
6.
Heart Lung Circ ; 27(6): 725-730, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28690021

RESUMEN

BACKGROUND: For nonagenarians with symptomatic severe aortic stenosis transcatheter aortic valve implantation (TAVI) has become a feasible therapeutic option. Therefore, the aim of this study was to evaluate the procedural outcomes and mid-term follow-up in this patient group and compare this to octogenarians. METHODS: From 1359 patients who underwent TAVI at our institution between March 2009 and February 2016, 82 patients were nonagenarians and 912 were octogenarians. In nonagenarians, mean age was 91.9±1.4years and compared to octogenarians showed a significantly higher logistic EuroScore (27.7±14.8% vs. 23.1±14.4, p=0.005) and STS Score (8.5±4.8% vs. 6.3±6.7, p=0.001). RESULTS: There were no significant differences with regard to stroke rate, pacemaker implantation rate and major vascular complications between the two groups. Thirty-day mortality was 9.8% in nonagenarians and 4.1% in octogenarians (p=0.04). At 1 year, all-cause mortality increased to 30.9% vs. 18.6% (n.s.). CONCLUSION: Nonagenarians showed an increased periprocedural mortality during TAVI and higher mortality in follow-up compared to octogenarians. Age alone is not a predictive factor but indication for treatment should be carefully evaluated by the heart team on an individual basis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Factores de Edad , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Angiografía Coronaria , Ecocardiografía , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Masculino , Tomografía Computarizada Multidetector/métodos , Pronóstico , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Factores de Tiempo
8.
Inflamm Res ; 63(4): 267-76, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24316867

RESUMEN

OBJECTIVE: The coxsackie and adenovirus receptor (CAR) mediates the entry of coxsackievirus B (CVB) and adenovirus into host cells and is, therefore, a key determinant for the molecular pathogenesis of viral diseases such as myocarditis. The aim was to investigate the influence of HMG-CoA reductase inhibitor lovastatin on CAR expression in endothelial cells. METHODS: Human umbilical vein endothelial cells (HUVECs) were exposed to different concentrations of lovastatin (0.05-5 µmol/l) for up to 48 h. Alterations in CAR expression were examined by quantitative real-time PCR (qRT-PCR) and flow cytometry. In addition, after treatment with 1 µmol/l lovastatin for 48 h, HUVECs were infected for 8 h with CVB3 and virus replication was detected by qRT-PCR using viral-specific TaqMan probes. RESULTS: We found that lovastatin decreases CAR mRNA expression by up to 80% (p < 0.01) and CAR protein expression by up to 19% (p < 0.01), in a concentration-dependent manner. Moreover, virus replication of CVB3 was significantly inhibited after lovastatin treatment (p < 0.05). The signaling mechanism of CAR down-regulation by lovastatin depends on the Rac1/Cdc42 pathway. CONCLUSION: This study shows for the first time that lovastatin reduces the expression of CAR and subsequently the replication of CVB3 in HUVECs.


Asunto(s)
Proteína de la Membrana Similar al Receptor de Coxsackie y Adenovirus/antagonistas & inhibidores , Enterovirus Humano B/efectos de los fármacos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/farmacología , Lovastatina/farmacología , Células Cultivadas , Proteína de la Membrana Similar al Receptor de Coxsackie y Adenovirus/genética , Proteína de la Membrana Similar al Receptor de Coxsackie y Adenovirus/metabolismo , Infecciones por Coxsackievirus/tratamiento farmacológico , Infecciones por Coxsackievirus/metabolismo , Infecciones por Coxsackievirus/virología , Enterovirus Humano B/fisiología , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Células Endoteliales de la Vena Umbilical Humana/virología , Humanos , ARN Mensajero/metabolismo , ARN Interferente Pequeño/genética , Replicación Viral/efectos de los fármacos , Proteína de Unión al GTP cdc42/genética , Proteína de Unión al GTP cdc42/metabolismo , Proteína de Unión al GTP rac1/genética , Proteína de Unión al GTP rac1/metabolismo
9.
Clin Res Cardiol ; 113(2): 336-352, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38170247

RESUMEN

BACKGROUND AND AIMS: Prosthetic valve endocarditis (PVE) is the prognostically most unfavourable complication after aortic valve replacement. This study aims to contribute to a better understanding of the different pathological and therapeutical aspects between PVE following surgical (SAVR) and transcatheter aortic valve replacement (TAVI). METHODS: All patients who had undergone primary isolated SAVR (n = 3447) or TAVI (n = 2269) at our Centre between 01/2012 and 12/2018 were analysed. Diagnosis of PVE was based on Duke criteria modified in 2015. Incidence, risk factors, pathogens, impact of complications or therapy on mortality were analysed and compared between SAVR- and TAVI-PVE. RESULTS: PVE incidence did not differ significantly after SAVR with 4.9/100 patient-years and TAVI with 2.4/100 patient-years (p = 0.49), although TAVI patients were older (mean 80 vs. 67 years) and had more comorbidities (STS score mean 5.9 vs. 1.6) (p < 0.001). TAVI prostheses with polymer showed a 4.3-fold higher risk to develop PVE than without polymer (HR 4.3; p = 0.004). Most common pathogens were staphylococci and enterococci (p > 0.05). Propensity-score matching analysis showed that the type of aortic valve replacement had no effect on the development of post-procedural PVE (p = 0.997). One-year survival was higher in TAVI-PVE patients treated with antibiotics only compared to additional surgical therapy (90.9% vs. 33.3%; p = 0.005). In SAVR-PVE patients, both therapies were comparable in terms of survival (p = 0.861). However, SAVR-PVE patients who were not operated, despite ESC-guideline recommendation, had significantly poorer one-year survival (p = 0.004). CONCLUSION: TAVI patients did not have a significantly higher risk to develop PVE. Our data suggest that TAVI-PVE patients in contrast to SAVR-PVE patients can more often be treated with antibiotics only, presumably due to the lack of a polymeric suture ring.


Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Endocarditis/epidemiología , Factores de Riesgo , Instrumentos Quirúrgicos , Antibacterianos/uso terapéutico , Polímeros , Catéteres/efectos adversos , Resultado del Tratamiento
10.
PLoS One ; 19(5): e0302793, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739601

RESUMEN

BACKGROUND: In cardiology, cardiac output (CO) is an important parameter for assessing cardiac function. While invasive thermodilution procedures are the gold standard for CO assessment, transthoracic Doppler echocardiography (TTE) has become the established method for routine CO assessment in daily clinical practice. However, a demand persists for non-invasive approaches, including oscillometric pulse wave analysis (PWA), to enhance the accuracy of CO estimation, reduce complications associated with invasive procedures, and facilitate its application in non-intensive care settings. Here, we aimed to compare the TTE and oscillometric PWA algorithm Antares for a non-invasive estimation of CO. METHODS: Non-invasive CO data obtained by two-dimensional TTE were compared with those from an oscillometric blood pressure device (custo med GmbH, Ottobrunn, Germany) using the integrated algorithm Antares (Redwave Medical GmbH, Jena, Germany). In total, 59 patients undergoing elective cardiac catheterization for clinical reasons (71±10 years old, 76% males) were included. Agreement between both CO measures were assessed by Bland-Altman analysis, Student's t-test, and Pearson correlations. RESULTS: The mean difference in CO was 0.04 ± 1.03 l/min (95% confidence interval for the mean difference: -0.23 to 0.30 l/min) for the overall group, with lower and upper limits of agreement at -1.98 and 2.05 l/min, respectively. There was no statistically significant difference in means between both CO measures (P = 0.785). Statistically significant correlations between TTE and Antares CO were observed in the entire cohort (r = 0.705, P<0.001) as well as in female (r = 0.802, P<0.001) and male patients (r = 0.669, P<0.001). CONCLUSIONS: The oscillometric PWA algorithm Antares and established TTE for a non-invasive estimation of CO are highly correlated in male and female patients, with no statistically significant difference between both approaches. Future validation studies of the Antares CO are necessary before a clinical application can be considered.


Asunto(s)
Algoritmos , Gasto Cardíaco , Ecocardiografía Doppler , Análisis de la Onda del Pulso , Humanos , Masculino , Femenino , Gasto Cardíaco/fisiología , Anciano , Análisis de la Onda del Pulso/métodos , Ecocardiografía Doppler/métodos , Persona de Mediana Edad , Anciano de 80 o más Años , Oscilometría/métodos
11.
Psychother Psychosom Med Psychol ; 63(7): 257-63, 2013 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-23475763

RESUMEN

Psychological symptoms are common in patients with heart disease. Objective of this study was to analyse the effects of somatic factors on anxiety and depression in hospitalised patients with heart failure. We examined 150 patients by short-term interview and standardized questionaire (HADS-D) and performed a written survey 3 months later. In 47% of the patients signs of anxiety and in 30% signs of depression were present. Increased heart failures severity was associated with increased rates of anxiety and depression. 3 months after hospital discharge the percentage of patients who reported symptoms of anxiety had decreased, the percentage of depressive female patients had increased. The course of anxiety and depression was not affected by cardiologic treatment. Patients with severe signs of anxiety and/or depression should receive specific diagnostics and therapy.


Asunto(s)
Insuficiencia Cardíaca/psicología , Insuficiencia Cardíaca/terapia , Adulto , Ansiedad/etiología , Ansiedad/psicología , Depresión/etiología , Depresión/psicología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Escalas de Valoración Psiquiátrica , Caracteres Sexuales
12.
Artículo en Inglés | MEDLINE | ID: mdl-36707104

RESUMEN

INTRODUCTION: Antares is a pulse wave analysis (PWA) algorithm designed to allow a non-invasive estimation of central (aortic) blood pressure (cBP) using automated oscillometric blood pressure (BP) devices. Diabetes may affect elastic and muscular arteries differently, resulting in disparate pulse wave characteristics in central and peripheral arteries, which may limit the accuracy of PWA devices. The aim of our study was to evaluate the accuracy of Antares for estimating cBP as compared with invasively measured cBP in patients with type 2 diabetes. RESEARCH DESIGN AND METHODS: In this study, consecutive patients undergoing elective coronary angiography were recruited between November 2017 and September 2020. In 119 patients with type 2 diabetes, cBP was measured invasively and simultaneously determined non-invasively using the custo screen 400 device with the integrated Antares algorithm. RESULTS: The mean difference between the estimated and invasively measured cBP was 1.2±6.3 mmHg for central systolic BP (cSBP), 1.0±4.3 mmHg for central mean arterial pressure (cMAP) and 3.6±5.7 mmHg for central diastolic BP (cDBP). High correlations were found between estimated cBP and invasively measured cBP (cSBP: r=0.916; cMAP: r=0.882; cDBP: r=0.791; all p<0.001). CONCLUSIONS: The present study suggests that the Antares algorithm incorporated into the custo screen 400 device can estimate cBP with high accuracy turning a conventional oscillometric BP device into a type II device for the non-invasive estimation of cBP, which is applicable in patients with type 2 diabetes. Integration of Antares into commercially available BP devices could facilitate the introduction of cBP into routine clinical practice as a part of disease and risk management.


Asunto(s)
Brazo , Diabetes Mellitus Tipo 2 , Humanos , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Diabetes Mellitus Tipo 2/diagnóstico , Análisis de la Onda del Pulso
13.
PLoS One ; 18(12): e0294075, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38096242

RESUMEN

BACKGROUND: Obesity is a global health concern and risk factor for cardiovascular disease. The assessment of central blood pressure (cBP) has been shown to improve prediction of cardiovascular events. However, few studies have investigated the impact of obesity on cBP in adults, and invasive data on this issue are lacking. This study aimed to evaluate cBP differences between patients with and without obesity, identify cBP determinants, and evaluate the accuracy of the algorithm Antares for non-invasive cBP estimation. METHODS: A total of 190 patients (25% female; 39% with BMI ≥30kg/m2; age: 67±12 years) undergoing elective cardiac catheterization were included. cBP was measured invasively and simultaneously estimated non-invasively using the custo screen 400 device with integrated Antares algorithm. RESULTS: No significant cBP differences were found between obese and non-obese patients. However, females, especially those with obesity, had higher systolic cBP compared to males (P<0.05). Multiple regression analysis showed that brachial mean arterial pressure, pulse pressure, BMI, and heart rate predicted cBP significantly (adjusted R2 = 0.82, P<0.001). Estimated cBP correlated strongly with invasive cBP for systolic, mean arterial, and diastolic cBP (r = 0.74-0.93, P<0.001) and demonstrated excellent accuracy (mean difference <5 and SD <8 mmHg). CONCLUSIONS: This study discovered no significant difference in cBP between obese and non-obese patients. However, it revealed higher cBP values in women, especially those with obesity, which requires further investigation. Additionally, the study highlights Antares' effectiveness in non-invasively determining cBP in obese individuals. This could improve the diagnosis and treatment of hypertension in this special patient population.


Asunto(s)
Determinación de la Presión Sanguínea , Hipertensión , Masculino , Adulto , Humanos , Femenino , Persona de Mediana Edad , Anciano , Presión Sanguínea/fisiología , Obesidad/complicaciones , Obesidad/diagnóstico , Técnicas de Diagnóstico Cardiovascular
14.
Echocardiography ; 29(6): 713-9, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22348380

RESUMEN

BACKGROUND: Dysfunction of heart valve prostheses (VP) is a life-threatening complication and the diagnosis remains difficult. The motivation for this study was to improve the detection of dysfunctional VP by optimizing application of the prosthetic effective orifice area (VA). For this reason the minimal expected normal VA (VA(expected)) was introduced. METHODS: We investigated echocardiographically 1,369 normally functioning aortic valve prostheses (AVP). Mean VA, transprosthetic peak (PPG) and mean pressure gradients (MPG) were evaluated to gain reference values depending on prosthetic size and construction principle. Mean VA(expected) was calculated by applying a simple formula that was developed empirically using statistical analyses. The results were compared with those of 65 dysfunctional AVPs. RESULTS: VA(expected) can be applied as a threshold between normal and dysfunctional stenotic AVP and showed a correct estimation in 87% of all normally functioning and 100% of dysfunctional stenotic VPs. The sensitivity for all prosthetic sizes is 1.0, independently of the constructional principle of the VP. Specificity ranged between 0.8 and 1.0, dependent on VP size. The formula representing VA(expected) is simple and can be executed easily. CONCLUSION: As nearly independent of stroke volume and in consideration of VA(expected), VA seems to have become one of the preferable parameters for detecting pathological stenotic AVPs echocardiographically. The additional application of PPG/MPG and other parameters permits prostheses with relevant isolated regurgitation and patient-prosthesis-mismatch to be distinguished.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Modelos de Riesgos Proporcionales , Falla de Prótesis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Anatomía Transversal , Niño , Interpretación Estadística de Datos , Análisis de Falla de Equipo/métodos , Análisis de Falla de Equipo/estadística & datos numéricos , Femenino , Alemania/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Medición de Riesgo , Ultrasonografía , Adulto Joven
15.
J Clin Med ; 11(15)2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35956185

RESUMEN

BACKGROUND: Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the balloon-expandable Sapien 3 (S3) regarding hemodynamics, PPI, and clinical outcome in these patients. METHODS: From 2014 to 2019, all patients with very severe calcification of the aortic valve who received an EPro or an S3 THV were included. Propensity score matching was utilized to create two groups of 170 patients. RESULTS: At discharge, there was significant difference in transvalvular gradients (EPro vs. S3) (dPmean 8.1 vs. 11.1 mmHg, p ≤ 0.001) and indexed effective orifice area (EOAi) (1.1 vs. 0.9, p ≤ 0.001), as well as predicted EOAi (1 vs. 0.9, p ≤ 0.001). Moderate patient prosthesis mismatch (PPM) was significantly lower in the EPro group (17.7% vs. 38%, p ≤ 0.001), as well as severe PPM (2.9% vs. 8.8%, p = 0.03). PPI and the PVL rate as well as stroke, bleeding, vascular complication, and 30-day mortality were comparable. CONCLUSIONS: In patients with severely calcified aortic valves, both THVs performed similarly in terms of 30-day mortality, PPI rate, and PVL occurrence. However, patient prothesis mismatch was observed more often in the S3 group, which might be due to the intra-annular design.

16.
Heart ; 108(21): 1729-1736, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35641178

RESUMEN

AIMS: Purpose of this study is to compare the clinical course and outcome of patients with recurrent versus first-episode infective endocarditis (IE). METHODS: Patients with recurrent and first-episode IE enrolled in the EUROpean ENDOcarditis (EURO-ENDO) registry including 156 centres were identified and compared using propensity score matching. Recurrent IE was classified as relapse when IE occurred ≤6 months after a previous episode or reinfection when IE occurred >6 months after the prior episode. RESULTS: 3106 patients were enrolled: 2839 (91.4%) patients with first-episode IE (mean age 59.4 (±18.1); 68.3% male) and 267 (8.6%) patients with recurrent IE (mean age 58.1 (±17.7); 74.9% male). Among patients with recurrent IE, 13.2% were intravenous drug users (IVDUs), 66.4% had a repaired or replaced valve with the tricuspid valve being more frequently involved compared with patients with first-episode IE (20.3% vs 14.1%; p=0.012). In patients with a first episode of IE, the aortic valve was more frequently involved (45.6% vs 39.5%; p=0.061). Recurrent relapse and reinfection were 20.6% and 79.4%, respectively. Staphylococcus aureus was the microorganism most frequently observed in both groups (p=0.207). There were no differences in in-hospital and post-hospitalisation mortality between recurrent and first-episode IE. In patients with recurrent IE, in-hospital mortality was higher in IVDU patients. Independent predictors of poorer in-hospital and 1-year outcome, including the occurrence of cardiogenic and septic shock, valvular disease severity and failure to undertake surgery when indicated, were similar for recurrent and first-episode IE. CONCLUSIONS: In-hospital and 1-year mortality was similar in patients with recurrent and first-episode IE who shared similar predictors of poor outcome.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Infecciones Estafilocócicas , Endocarditis/diagnóstico , Endocarditis/cirugía , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/cirugía , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Reinfección , Estudios Retrospectivos , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/cirugía
17.
Postgrad Med J ; 87(1029): 458-62, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21441165

RESUMEN

BACKGROUND: There are as yet no data on the prevalence of sleep apnoea in patients with severe aortic stenosis (AS). AIMS: To assess the occurrence, severity and clinical correlates of sleep apnoea in patients with AS. METHODS: During a 4-month period in 2010, 67 patients were consecutively included in this study, 42 of which (19 men; mean±SD age 72±9 years) had severe AS (aortic valve opening area≤1.0 cm2); all were investigated with cardiorespiratory polygraphy. Sleep apnoea was diagnosed if the apnoea-hypopnoea index (AHI) (median (lower quartile, upper quartile)) was ≥5/h. The control group of 25 patients matched for age, body mass index and sex had angiographic exclusion of coronary artery disease, regular left ventricular ejection fraction, and no valve disease. RESULTS: Sleep apnoea was found in 30/42 patients with AS (71%; AHI=23/h (14/h, 36/h)). The severity was significantly greater in patients with severe AS than in the control group (AHI=12/h (8/h, 17/h)) (p<0.01). Half of the patients with sleep apnoea had obstructive sleep apnoea (OSA) (AHI=15/h (9/h, 28/h)), and half had central sleep apnoea (CSA) (AHI=25/h (18/h, 45/h)). New York Heart Association classification and severity of sleep apnoea correlated with η=0.5 (η2=0.3). The severity of CSA correlated with pulmonary artery pressure (r=0.7, p<0.01) and pulmonary capillary wedge pressure (r=0.7, p<0.01). Patients with AS and CSA had a lower PCO2 than those with OSA and those without sleep apnoea (p<0.01). CONCLUSIONS: Sleep apnoea is common in patients with severe AS. The severity of CSA correlates with pulmonary hypertension, which may suggest that myocardial adaptation is exhausting.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Síndromes de la Apnea del Sueño/etiología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Índice de Masa Corporal , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Índice de Severidad de la Enfermedad , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/fisiopatología , Estadística como Asunto
18.
Eur Heart J ; 31(9): 1105-13, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20093256

RESUMEN

AIMS: A new diagnostic strategy to improve the detection of pathogens in heart valves (HVs) from patients with infective endocarditis (IE) was evaluated. METHODS AND RESULTS: Three hundred and fifty seven HVs surgically removed from 326 patients with proven IE or suspicious intra-operative findings, examined by 16S rDNA polymerase chain reaction (PCR) and culture were retrospectively analysed according to the predictive value of various PCR methods. Patients were classified into four categories: active IE, IE with ambiguous infective status, healed IE, and valve diseases but no IE. Retained samples of 200 HVs were analysed by real-time PCR targeting bacterial 23S rDNA, fungal 28S rDNA, and mycoplasmal tuf gene. 16S rDNA PCR revealed 80.6% sensitivity, 100% specificity, 100% positive predictive value, and 71% negative predictive value (NPV), compared with cultivation with 33.4, 96.6, 95.5, and 40.9%, respectively. The use of real-time PCR increased diagnostic sensitivity to 96.4%, and NPV to 92.5%. Bacterial load, C-reactive protein, and white blood cell counts (WBCs) decreased during antibiotic treatment. Bacterial load showed no correlation to C-reactive protein or WBCs, whereas C-reactive protein and WBCs were significantly correlated. CONCLUSION: 23S rDNA real-time PCR of surgically removed HVs improves the diagnosis of IE. Polymerase chain reaction analysis of explanted HVs allow the optimization of the antimicrobial therapy, especially in patients with culture-negative IE.


Asunto(s)
ADN Ribosómico/metabolismo , Endocarditis/diagnóstico , Enfermedades de las Válvulas Cardíacas/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , Adolescente , Adulto , Anciano , Biomarcadores/metabolismo , Femenino , Válvulas Cardíacas/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
19.
Front Cardiovasc Med ; 8: 766996, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34859076

RESUMEN

Background: The interplay between cancer and IE has become of increasing interest. This study sought to assess the prevalence, baseline characteristics, management, and outcomes of IE cancer patients in the ESC EORP EURO-ENDO registry. Methods: Three thousand and eighty-five patients with IE were identified based on the ESC 2015 criteria. Three hundred and fifty-nine (11.6%) IE cancer patients were compared to 2,726 (88.4%) cancer-free IE patients. Results: In cancer patients, IE was mostly community-acquired (74.8%). The most frequently identified microorganisms were S. aureus (25.4%) and Enterococci (23.8%). The most frequent complications were acute renal failure (25.9%), embolic events (21.7%) and congestive heart failure (18.1%). Theoretical indication for cardiac surgery was not significantly different between groups (65.5 vs. 69.8%, P = 0.091), but was effectively less performed when indicated in IE patients with cancer (65.5 vs. 75.0%, P = 0.002). Compared to cancer-free IE patients, in-hospital and 1-year mortality occurred in 23.4 vs. 16.1%, P = 0.006, and 18.0 vs. 10.2%; P < 0.001, respectively. In IE cancer patients, predictors of mortality by multivariate analysis were creatinine > 2 mg/dL, congestive heart failure and unperformed cardiac surgery (when indicated). Conclusions: Cancer in IE patients is common and associated with a worse outcome. This large, observational cohort provides new insights concerning the contemporary profile, management, and clinical outcomes of IE cancer patients across a wide range of countries.

20.
J Gen Virol ; 91(Pt 8): 1959-1970, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20392896

RESUMEN

In viral myocarditis, adeno- and enteroviruses have most commonly been implicated as causes of infection. Both viruses require the human coxsackie-adenovirus receptor (CAR) to infect the myocardium. Due to its crucial role for viral entry, CAR-downregulation may lead to novel approaches for treatment for viral myocarditis. In this study, we report on pharmaceutical drug influences on CAR levels in human umbilical vein endothelial cells (HUVEC) and cervical carcinoma cells (HeLa) detected by immunoblotting, quantitative real time-PCR and cellular susceptibility to the cardiotropic coxsackie-B3 virus strain Nancy (CVB3). Our results indicate, for the first time, a dose-dependent CAR mRNA and protein downregulation upon Valsartan and Bosentan treatment. Most interestingly, drug-induced CAR diminution significantly reduced the viral load in CVB3-infected HUVEC. In order to assess the regulatory effects of both drugs in detail, we knocked down their protein targets, the G-protein coupled receptors angiotensin-II type-1 receptor (AT(1)R) and endothelin-1 type-A and -B receptors (ET(A)R/ET(B)R) in HUVEC. Receptor-specific gene silencing indicates that CAR gene expression is regulated by agonistic and antagonistic binding to ET(B)R, but not ET(A)R. In addition, neither stimulation nor inhibition of AT(1)R seemed to be involved in CAR gene regulatory processes. Our study indicates that Valsartan and Bosentan protected human endothelial cells from CVB3-infection. Therefore, besides their well-known anti-hypertensive effects these drugs may also protect the myocardium and other tissues from coxsackie- and adenoviral infection.


Asunto(s)
Antivirales/farmacología , Células Endoteliales/virología , Enterovirus Humano B/efectos de los fármacos , Receptores Virales/biosíntesis , Sulfonamidas/farmacología , Tetrazoles/farmacología , Valina/análogos & derivados , Replicación Viral/efectos de los fármacos , Bosentán , Proteína de la Membrana Similar al Receptor de Coxsackie y Adenovirus , Regulación hacia Abajo , Enterovirus Humano B/fisiología , Células Epiteliales/virología , Expresión Génica , Células HeLa , Humanos , ARN Mensajero/biosíntesis , Receptores Virales/antagonistas & inhibidores , Valina/farmacología , Valsartán , Carga Viral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA