Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Metabolomics ; 20(3): 57, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773045

RESUMEN

BACKGROUND: Despite the clear clinical diagnostic criteria for necrozoospermia in andrology, the fundamental mechanisms underlying it remain elusive. This study aims to profile the lipid composition in seminal plasma systematically and to ascertain the potential of lipid biomarkers in the accurate diagnosis of necrozoospermia. It also evaluates the efficacy of a lipidomics-based random forest algorithm model in identifying necrozoospermia. METHODS: Seminal plasma samples were collected from patients diagnosed with necrozoospermia (n = 28) and normozoospermia (n = 28). Liquid chromatography-mass spectrometry (LC-MS) was used to perform lipidomic analysis and identify the underlying biomarkers. A lipid functional enrichment analysis was conducted using the LION lipid ontology database. The top 100 differentially significant lipids were subjected to lipid biomarker examination through random forest machine learning model. RESULTS: Lipidomic analysis identified 46 lipid classes comprising 1267 lipid metabolites in seminal plasma. The top five enriched lipid functions as follows: fatty acid (FA) with ≤ 18 carbons, FA with 16-18 carbons, monounsaturated FA, FA with 18 carbons, and FA with 16 carbons. The top 100 differentially significant lipids were subjected to machine learning analysis and identified 20 feature lipids. The random forest model identified lipids with an area under the curve > 0.8, including LPE(20:4) and TG(4:0_14:1_16:0). CONCLUSIONS: LPE(20:4) and TG(4:0_14:1_16:0), were identified as differential lipids for necrozoospermia. Seminal plasma lipidomic analysis could provide valuable biochemical information for the diagnosis of necrozoospermia, and its combination with conventional sperm analysis may improve the accuracy and reliability of the diagnosis.


Asunto(s)
Algoritmos , Lipidómica , Semen , Adulto , Humanos , Masculino , Biomarcadores/sangre , Infertilidad Masculina/diagnóstico , Infertilidad Masculina/metabolismo , Lipidómica/métodos , Lípidos/análisis , Lípidos/sangre , Aprendizaje Automático , Bosques Aleatorios , Semen/metabolismo , Semen/química , Cromatografía Líquida con Espectrometría de Masas
2.
Sensors (Basel) ; 24(7)2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38610534

RESUMEN

This study explores the important role of assessing force levels in accurately controlling upper limb movements in human-computer interfaces. It uses a new method that combines entropy to improve the recognition of force levels. This research aims to differentiate between different levels of isometric contraction forces using electroencephalogram (EEG) signal analysis. It integrates eight different entropy measures: power spectrum entropy (PSE), singular spectrum entropy (SSE), logarithmic energy entropy (LEE), approximation entropy (AE), sample entropy (SE), fuzzy entropy (FE), alignment entropy (PE), and envelope entropy (EE). The findings emphasize two important advances: first, including a wide range of entropy features significantly improves classification efficiency; second, the fusion entropy method shows exceptional accuracy in classifying isometric contraction forces. It achieves an accuracy rate of 91.73% in distinguishing between 15% and 60% maximum voluntary contraction (MVC) forces, along with 69.59% accuracy in identifying variations across 15%, 30%, 45%, and 60% MVC. These results illuminate the efficacy of employing fusion entropy in EEG signal analysis for isometric contraction detection, heralding new opportunities for advancing motor control and facilitating fine motor movements through sophisticated human-computer interface technologies.


Asunto(s)
Electroencefalografía , Contracción Isométrica , Humanos , Entropía , Movimiento , Reconocimiento en Psicología
3.
Sci Data ; 11(1): 350, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589476

RESUMEN

Maintaining sufficient cerebral oxygen metabolism is crucial for human survival, especially in challenging conditions such as high-altitudes. Human cognitive neural activity is sensitive to fluctuations in oxygen levels. However, there is a lack of publicly available datasets on human behavioural responses and cerebral dynamics assessments during the execution of conflicting tasks in natural hypoxic environments. We recruited 80 healthy new immigrant volunteers (males, aged 20 ± 2 years) and employed the Stroop cognitive conflict paradigm. After a two-week exposure to both high and low-altitudes, the behavioural performance, prefrontal oxygen levels, and electroencephalography (EEG) signals were recorded. Comparative analyses were conducted on the behavioural reaction times and accuracy during Stroop tasks, and statistical analyses of participants' prefrontal oxygen levels and EEG signals were performed. We anticipate that our open-access dataset will contribute to the development of monitoring devices and algorithms, designed specifically for measuring cerebral oxygen and EEG dynamics in populations exposed to extreme environments, particularly among individuals suffering from oxygen deficiency.


Asunto(s)
Altitud , Electroencefalografía , Humanos , Masculino , Oxígeno/análisis , Tiempo de Reacción/fisiología , Test de Stroop , Adulto Joven , Emigrantes e Inmigrantes
4.
Adv Sci (Weinh) ; : e2405273, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39116352

RESUMEN

Conductive gel interface materials are widely employed as reliable agents for electroencephalogram (EEG) recording. However, prolonged EEG recording poses challenges in maintaining stable and efficient capture due to inevitable evaporation in hydrogels, which restricts sustained high conductivity. This study introduces a novel ion-electron dual-mode conductive hydrogel synthesized through a cost-effective and streamlined process. By embedding graphite nanoparticles into ionic hyaluronic acid (HAGN), the hydrogel maintains higher conductivity for over 72 h, outperforming commercial gels. Additionally, it exhibits superior low skin contact impedance, considerable electrochemical capability, and excellent tensile and adhesion performance in both dry and wet conditions. The biocompatibility of the HAGN hydrogel, verified through in vitro cell viability assays and in vivo skin irritation tests, underscores its suitability for prolonged skin contact without eliciting adverse reactions. Furthermore, in vivo EEG tests confirm the HAGN hydrogel's capability to provide high-fidelity signal acquisition across multiple EEG protocols. The HAGN hydrogel proves to be an effective interface for prolonged high-quality EEG recording, facilitating high-performance capture and classification of evoked potentials, thereby providing a reliable conductive medium for EEG-based systems.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA