Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 261(9): 2489-2495, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37036511

RESUMEN

PURPOSE: This study is to assess the possible correlation between findings on fundus autofluorescence (FAF) and fluorescein angiography (FA) in patients with chronic central serous chorioretinopathy (cCSC). METHODS: This multicentre retrospective cohort study included 71 cCSC patients (92 eyes) with at least 6 months of follow-up, who had a FAF-FA imaging discrepancy larger than 0.5 optic disc diameters in size in the corresponding areas of hyperfluorescent abnormalities. A comparison was performed between progression in size of areas of hyperautofluorescent retinal pigment epithelium (RPE) abnormalities on FAF (HF-FAF) and the hyperfluorescent areas on FA (HF-FA) at first visit and last visit. The possible correlations were estimated between FAF-FA discrepancy and disease characteristics. RESULTS: The median area of HF-FAF at first visit was 7.48 mm2 (1.41-27.9). The median area of HF-FA at first visit and last visit was 2.40 mm2 (0.02-17.27) and 5.22 mm2 (0.53-25.62), respectively. FAF-FA discrepancy was associated with follow-up duration and the area of HF-FAF at first visit. A mathematical algorithm for grading FAF-FA discrepancy in time was suggested, which predicted the enlargement of hyperfluorescent RPE abnormalities on FA in 82.6% of cases. CONCLUSION: There is a statistically significant relationship between the areas of HF-FAF and HF-FA in cCSC patients with FAF-FA imaging discrepancy at first presentation. Long-term changes in RPE alterations in cCSC on FA can be predicted based on baseline HF-FAF and follow-up duration.


Asunto(s)
Coriorretinopatía Serosa Central , Humanos , Coriorretinopatía Serosa Central/diagnóstico , Angiografía con Fluoresceína/métodos , Estudios Retrospectivos , Fondo de Ojo , Enfermedad Crónica , Tomografía de Coherencia Óptica
2.
Graefes Arch Clin Exp Ophthalmol ; 258(9): 1965-1974, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32500303

RESUMEN

PURPOSE: Silicone oil is used as endotamponade in combination with vitrectomy. Thinning of retinal layers and loss of retinal cells under silicone oil use have been found. Here, we investigate the influence of silicone oil on primary microglia cells. METHODS: Primary microglia cells were prepared from the porcine retina. Microglia identity was assessed with Iba1 staining. Silicone oil was emulsified by sonification. Cell morphology and silicone oil uptake were evaluated by light microscopy after Coomassie blue staining. Cytokine secretion was evaluated with ELISA. Toxicity of silicone oil on microglia and toxic effect of silicone oil-treated microglia on neuronal cell line PC12 were evaluated by MTT or WST assay, respectively. RESULTS: Microglia took up silicone oil droplets after 72 h of incubation. Silicone oil induced no toxicity but increased the metabolism in microglial cells. In addition, the secretion of IL-6 and IL-8, but not of IL-1ß or TNF-α, was induced. Silicone oil-treated microglia did not exert any neurotoxic effect on differentiated PC12 cells but induced an increase in metabolism. CONCLUSION: Emulsified silicone oil changes the activity level of microglia and induces the secretion of IL-6 and IL-8. Neurotoxicity is not induced. Further experiments are required to investigate the long-term effect of silicone oil on microglia and their consequent effect on neuronal cells.


Asunto(s)
Endotaponamiento/métodos , Microglía/efectos de los fármacos , Enfermedades de la Retina/cirugía , Aceites de Silicona/administración & dosificación , Vitrectomía/métodos , Animales , Células Cultivadas , Modelos Animales de Enfermedad , Emulsiones/administración & dosificación , Ratas , Desprendimiento de Retina , Enfermedades de la Retina/diagnóstico , Porcinos , Tomografía de Coherencia Óptica
3.
BMC Ophthalmol ; 19(1): 14, 2019 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-30630462

RESUMEN

BACKGROUND: To evaluate long-term results of eyes with glaucoma drainage device (GDD). METHODS: We retrospectively reviewed medical records of all patients who underwent GDD placement at our institution between 2001 and 2014. A total of 110 eyes of 90 patients were studied. Glaucoma outcome was assessed by postoperative intraocular pressure (IOP), number of medications, and need for further glaucoma surgery. Surgical procedures before and during the study period, and their complications were evaluated. RESULTS: The mean follow-up was 78.3 ± 44.0 months. The mean preoperative intraocular pressure was 30.8 ± 6.9 mmHg with 3.5 ± 1.1 glaucoma medications. At last postoperative follow-up, the mean IOP decreased to 14.3 ± 5.4 mmHg with 1.6 ± 1.5 glaucoma medications. GDD implantation successfully controlled glaucoma in 86, 85, 81, 78, 79, 76 and 73% of eyes at 1, 2, 3, 4, 5, 7 and 10 years, respectively. At last follow-up IOP was successfully controlled in 67% of eyes. Clinical complications occurred in 56.4% of eyes during the follow-up period. CONCLUSIONS: A glaucoma drainage device can successfully control intractable glaucoma even after a very long period of time.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antihipertensivos/uso terapéutico , Niño , Preescolar , Femenino , Glaucoma/fisiopatología , Humanos , Presión Intraocular/fisiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Implantación de Prótesis , Estudios Retrospectivos , Tonometría Ocular , Agudeza Visual/fisiología , Adulto Joven
4.
BMC Ophthalmol ; 19(1): 26, 2019 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-30665380

RESUMEN

BACKGROUND: A few case reports have described accidental eye injuries caused by fish hooks. The severity of ocular injuries is dependent on the involved ocular structures. Severe ocular injuries due to fish hooks are rare. We describe open globe and penetrating eyelid injuries from fish hooks at the Baltic Sea. METHODS: Nine patients with traumatic ocular injuries caused by fish hooks were included. The following parameters were evaluated: severity of injury, best corrected visual acuity at admission and last follow-up, and surgical treatment. RESULTS: All nine patients were male. Age ranged between 7 and 51 years with a median of 13 years. Sixty-seven percent of the patients were children. Four of the nine patients were 9 years or younger. In 5 eyes (55%) the injury was limited to the eyelid. An open globe injury was found in 4 patients (45%). The mean follow-up was 16.7 ± 32.8 months. All patients required surgical treatment. The number of operations ranged from 1 to 3, with a mean of 1.4. At admission and last follow-up, patients with eyelid injuries showed a median best corrected visual acuity (BCVA) of logMAR 0.0. Patients with open globe injuries showed a median best corrected visual acuity of logMAR 1.5 at admission, and of logMAR 0.6 at last follow-up. CONCLUSIONS: Nearly half of the patients suffered severe penetrating injuries. Especially children misjudge the risk potential of fishing due to their lack of experience. Fishing glasses should be worn not only for UV protection, but also as injury prevention strategy.


Asunto(s)
Cuerpos Extraños en el Ojo/etiología , Lesiones Oculares Penetrantes/etiología , Recreación , Adolescente , Adulto , Niño , Cuerpos Extraños en el Ojo/fisiopatología , Cuerpos Extraños en el Ojo/cirugía , Lesiones Oculares Penetrantes/fisiopatología , Lesiones Oculares Penetrantes/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Agudeza Visual/fisiología , Adulto Joven
5.
Graefes Arch Clin Exp Ophthalmol ; 256(11): 2027-2034, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30097783

RESUMEN

PURPOSE: Different modes of photodynamic therapy (PDT) were described for treatment of central serous chorioretinopathy (CSC). The purpose of the current study was to evaluate the outcome of half-time PDT in chronic CSC. METHODS: A retrospective case series study, including 114 eyes of 103 patients with chronic CSC, treated with reduced-fluence PDT. PDT was applied with full-dose verteporfin (6 mg/m2) and half-time fluence (43 s). The main outcome measures included timing of complete subretinal fluid (SRF) resolution, recurrences, pre- and post-treatment best-corrected visual acuities (BCVA). Anatomical and functional effects were compared in subgroup analysis on the basis of CSC treatment efficacy. Subsequent analysis was performed to compare eyes with and without recurrences and CSC eyes treated by single and multiple PDT sessions. RESULTS: A total of 114 eyes of 103 patients (81 male; 22 female) were analyzed. The median age was 49 (28-70). The median CSC pretreatment duration was 12 months (3-393). The median follow-up period after PDT was 8 months (6-111). By the sixth-month period PDT was effective in 80% (91 eyes), with a subsequent enhancement up to 87% (99 eyes) at 12th month and not effective in 13% (15 eyes). SRF resolution was achieved after 8 weeks (2-44) with a significant improvement of median LogMAR BCVA from 0.22 (- 0.2-1.3) before PDT to 0.1 (- 0.2-1.0) at last visit after PDT (p < 0.0001). CONCLUSIONS: Half-time PDT has proven to be an effective and safe treatment option for patients with chronic CSC with a significant BCVA improvement during the follow-up after the therapy.


Asunto(s)
Coriorretinopatía Serosa Central/tratamiento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Porfirinas/uso terapéutico , Adulto , Anciano , Coriorretinopatía Serosa Central/diagnóstico , Enfermedad Crónica , Colorantes/administración & dosificación , Femenino , Angiografía con Fluoresceína , Estudios de Seguimiento , Humanos , Verde de Indocianina/administración & dosificación , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Líquido Subretiniano , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Verteporfina , Agudeza Visual/fisiología
6.
Graefes Arch Clin Exp Ophthalmol ; 256(9): 1623-1629, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29915918

RESUMEN

PURPOSE: Current algorithms for automated computer interpretation of optical coherence tomography (OCT) imaging of patients suffering from neovascular age-related macular degeneration (AMD) mostly rely on fluid detection. However, fluid detection itself and correct interpretation of the fluid currently limits diagnostic accuracy. We therefore performed a detailed analysis of the requirements that would have to be met for fluid detection approaches. We further investigated if monitoring retinal volume would be a viable alternative to detect disease activity. METHODS: Retrospective analysis and manual grading of 764 OCT volume scans of 44 patients with exudative AMD treated with intravitreal anti-VEGF injections at a pro-re-nata (PRN) treatment regimen for at least 24 months. RESULTS: Detection of subretinal fluid (SRF) or intraretinal fluid (IRF) alone is not sufficient for disease detection. A combination of SRF and IRF can detect disease activity with a sensitivity of 98.6% and a specificity of 82%. With further characterization of IRF into exudative and degenerative cysts, specificity can be increased to 100%. However, correct characterization is currently not achieved by published fluid detection approaches. Change of macular retinal volume (MRV) can depict disease activity with sensitivity of 88.4% and specificity of 89.6%. Combination with the detection of SRF can further improve diagnostic accuracy to a specificity of 93.3% and sensitivity of 93.9% without relying on IRF or IRF characterization. CONCLUSION: Fluid detection without further characterization is not sufficient for AMD monitoring. Either further distinction between exudative and degenerative cysts is necessary, or other activity markers have to be taken into account. MRV offers good potential to fill this diagnostic gap and might become an important monitoring marker.


Asunto(s)
Biomarcadores , Neovascularización Coroidal/diagnóstico , Retina/patología , Tomografía de Coherencia Óptica/métodos , Degeneración Macular Húmeda/diagnóstico , Anciano , Inhibidores de la Angiogénesis/uso terapéutico , Bevacizumab/uso terapéutico , Neovascularización Coroidal/tratamiento farmacológico , Femenino , Humanos , Inyecciones Intravítreas , Masculino , Ranibizumab/uso terapéutico , Receptores de Factores de Crecimiento Endotelial Vascular/uso terapéutico , Proteínas Recombinantes de Fusión/uso terapéutico , Retina/diagnóstico por imagen , Estudios Retrospectivos , Sensibilidad y Especificidad , Líquido Subretiniano/diagnóstico por imagen , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Degeneración Macular Húmeda/tratamiento farmacológico
7.
Ophthalmologica ; 239(1): 19-26, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29050013

RESUMEN

PURPOSE: To evaluate long-term outcome after revitrectomy with autologous platelet concentrate (APC) or whole blood (WB) in persistent idiopathic macular hole (MH) after vitrectomy with internal limiting membrane (ILM) peeling. PROCEDURES: Retrospective study of 75 eyes with persistent MH after vitrectomy with ILM peeling and gas. All patients underwent revitrectomy with gas and APC (n = 61) or WB (n = 14). Main outcome measures were anatomical closure rate and postoperative best-corrected visual acuity (BCVA). RESULTS: Closure rate after revitrectomy was 85.2% (52/61) in the APC group and 7.1% (1/14) in the WB group. Median follow-up was 58 (range 3-147) months. Median BCVA (logMAR) in patients with finally closed MHs was 0.4 ± 0.3. Patients with defects of the ellipsoid zone had significantly worse postoperative BCVA. Morphological MH configuration (atrophic or elevated edges) did not correlate with final closure rate. CONCLUSIONS: Revitrectomy with APC and gas is a very effective treatment in persistent MH after vitrectomy with ILM peeling and gas.


Asunto(s)
Plaquetas , Transfusión de Sangre Autóloga/métodos , Mácula Lútea/patología , Perforaciones de la Retina/terapia , Tomografía de Coherencia Óptica/métodos , Agudeza Visual , Vitrectomía/métodos , Anciano , Anciano de 80 o más Años , Endotaponamiento/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Perforaciones de la Retina/diagnóstico , Perforaciones de la Retina/etiología , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
8.
Graefes Arch Clin Exp Ophthalmol ; 255(5): 1037-1042, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28303330

RESUMEN

PURPOSE: Rotating wire brushes are used, e.g., for rust removal. Detaching fragments can cause severe eye injuries. The purpose of this study was to investigate mechanism, severity, clinical outcome, validity of Ocular Trauma Score (OTS) and to assess the likelihood of final visual acuity. METHODS: Twenty patients with traumatic ocular injuries by rotating wire brushes were included. Location and type of injury, grade of injury according to OTS, surgical procedure, and development of visual acuity were evaluated. RESULTS: Eleven accidents (55%) happened at work, nine at home (45%). Eighteen injuries (90%) were penetrating, one (5%) was perforating. In one case (5%), an intraocular foreign body was present. One case each was classified OTS 1 and 2 (5%), six cases OTS 3 (30%), four cases OTS 4 (20%), and eight cases OTS 5 (40%). None of the patients was wearing safety goggles. Fourteen patients (70%) were surgically treated. Of these, five were treated at the anterior segment only, nine additionally underwent pars-plana vitrectomy. Nine patients received phacoemulsification. Mean best corrected visual acuity was logMAR 1.0 (2/20) at admission and 0.3 (10/20) at last follow-up. Our results were similar to those in the OTS study, except for OTS 1 (p = 0.046). Comparing the categorical distribution of final visual acuity in all OTS categories, no statistically significant difference was found (p = 0.119) between our results and the OTS study group. CONCLUSIONS: OTS may provide prognostic information in traumatic ocular injuries by rotating wire brushes. The injuries could have been avoided by wearing safety goggles.


Asunto(s)
Cuerpos Extraños en el Ojo/diagnóstico , Lesiones Oculares Penetrantes/diagnóstico , Dispositivos de Protección de los Ojos , Agudeza Visual , Adulto , Anciano , Anciano de 80 o más Años , Cuerpos Extraños en el Ojo/prevención & control , Cuerpos Extraños en el Ojo/cirugía , Lesiones Oculares Penetrantes/prevención & control , Lesiones Oculares Penetrantes/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Oftalmológicos/métodos , Pronóstico , Estudios Retrospectivos , Índices de Gravedad del Trauma , Adulto Joven
9.
Graefes Arch Clin Exp Ophthalmol ; 255(1): 49-59, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27405976

RESUMEN

BACKGROUND: Photocoagulation lesion intensity relies on the judgement of retinal blanching. Lesions turn out variable due to observer-dependent judgement and time dependency of blanching. We investigated lesion variability per patient and per physician in clinical routine treatments. METHODS: In this observational clinical trial, different physicians performed panretinal photocoagulation for diabetic retinopathy. Study eyes received 20-30 study lesions at 20 ms (three physicians, nine eyes) and 200 ms (four physicians, 12 eyes) irradiation time (532 nm continuous wave photocoagulator, 300 µm spot size). Lesions were imaged after 1 hour with photography and optical coherence tomography (OCT). We measured lesion diameters in fundus and OCT images, and graded intensities according to a previously published six-step classifier. RESULTS: 200-ms lesions were larger and more severe (568, 474-625 µm [median, IQR], predominantly class 6) than 20-ms lesions (397, 347-459 µm, predominantly classes 3-4). The impact of laser power was small compared to other factors. Lesion intensities and diameters in fundus and OCT images varied significantly between patients and between physicians. Median photographic lesion diameters varied by up to a factor of 1.61 (20 ms) or 1.5 (200 ms) respectively. CONCLUSIONS: In this study, the treated area of retina varied by up to a factor of 1.612 = 2.59 for a given spot number. As clinical efficacy depends on the treated area, which is a function of lesion number by area per lesion, our results implicate poor control of the overall treatment effect if treatments are administered according to lesion number or spacing alone. Better ways of laser effect control should be sought.


Asunto(s)
Competencia Clínica , Retinopatía Diabética/cirugía , Coagulación con Láser/métodos , Médicos/normas , Retina/patología , Adulto , Retinopatía Diabética/diagnóstico , Femenino , Angiografía con Fluoresceína , Fondo de Ojo , Humanos , Masculino , Persona de Mediana Edad , Retina/cirugía , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento
10.
Ophthalmologica ; 238(3): 124-132, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28719903

RESUMEN

PURPOSE: To evaluate retinal layer thickness with optical coherence tomography (OCT) in eyes with macula-off retinal detachment after silicone oil (SiO) or gas endotamponade. PROCEDURES: Cross-sectional study of 40 eyes with macula-off rhegmatogenous retinal detachment that underwent vitrectomy. 20 eyes received SiO tamponade and 20 matched eyes received gas. 33 healthy fellow eyes served as controls. Macular spectral domain OCT was performed with automated layer detection in the 5 inner subfields of the Early Treatment Diabetic Retinopathy Study (ETDRS) map. RESULTS: Comparing the SiO group with the gas group, the ganglion cell layer showed a significant thinning in all fields of the inner ring of the ETDRS map, the inner plexiform layer in the nasal, superior and temporal quadrants, and the outer plexiform layer in the nasal quadrant. CONCLUSIONS: Inner retinal layers in the fovea/parafovea were significantly thinner in the SiO group. Prospective studies are warranted to further elucidate possible retinal adverse effects of SiO tamponade.


Asunto(s)
Endotaponamiento/métodos , Mácula Lútea/patología , Desprendimiento de Retina/cirugía , Aceites de Silicona/administración & dosificación , Tomografía de Coherencia Óptica/métodos , Vitrectomía/métodos , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Desprendimiento de Retina/diagnóstico , Agudeza Visual
11.
Graefes Arch Clin Exp Ophthalmol ; 254(8): 1465-1471, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27278374

RESUMEN

PURPOSE: We aimed to investigate frequency, time course and pathophysiology of vision loss in eyes with macula-on rhegmatogenous retinal detachment operated with vitrectomy and silicone oil tamponade. PATIENTS AND METHODS: Fifteen eyes of 15 patients who had been operated with 5,000 centistoke silicone oil between 2006 and 2014 were included in a retrospective case series. Examinations included logMAR best corrected visual acuity (BCVA), visual field testing (VF), spectral domain optical coherence tomography (OCT), electrophysiology, and fluorescein angiography. RESULTS: Vision loss was seen in eight (53 %) eyes of 15 patients with symptomatic central scotoma, which was confirmed by VF (5/6). Preoperative median BCVA of these patients was 0.15 (0.5 to 0), prior to oil removal 0.7 (1.0 to 0.5), and 6 weeks post oil removal 1.0 (1.5 to 0.2). BCVA recovered in five patients to a median of 0.15 (0.5 to 0.1), and it remained 1.0 in three (20 %) out of 15 eyes. OCT revealed significant thinning of the foveal and parafoveal combined nerve fiber, ganglion cell and inner plexiform layers in affected eyes (mean 58.3 µm +/-13, horizontal scan through fovea, 500 µm radius) compared to their healthy fellow eyes (mean 84.5 µm +/-12.3; p < 0.01, n = 6 patients, 12 eyes) and compared to eyes with no vision loss under silicone oil. CONCLUSIONS: We find persisting vision loss in three out of 15 patients treated for macula-on rhegmatogenous retinal detachment with silicone oil tamponade. Thinning of inner retinal layers possibly evoked by silicone oil tamponade might be a pathophysiological explanation for vision loss in these patients.


Asunto(s)
Ceguera/etiología , Complicaciones Posoperatorias , Desprendimiento de Retina/cirugía , Aceites de Silicona/administración & dosificación , Vitrectomía/efectos adversos , Anciano , Ceguera/diagnóstico , Ceguera/fisiopatología , Femenino , Angiografía con Fluoresceína , Estudios de Seguimiento , Fondo de Ojo , Humanos , Masculino , Persona de Mediana Edad , Desprendimiento de Retina/diagnóstico , Estudios Retrospectivos , Factores de Tiempo , Tomografía de Coherencia Óptica , Agudeza Visual , Vitrectomía/métodos
12.
BMJ Open ; 12(6): e055082, 2022 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-35760534

RESUMEN

OBJECTIVES: Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) is a novel OCT technology that was specifically designed for home monitoring of neovascular age-related macular degeneration (AMD). First clinical findings have been reported before. This trial investigates an improved prototype for patients with AMD and focusses on device operability and diagnostic accuracy compared with established spectral-domain OCT (SD-OCT). DESIGN: Prospective single-arm diagnostic accuracy study. SETTING: Tertiary care centre (University Eye Clinic). PARTICIPANTS: 46 patients with age-related macular degeneration. INTERVENTIONS: Patients received short training in device handling and then performed multiple self-scans with the SELFF-OCT according to a predefined protocol. Additionally, all eyes were examined with standard SD-OCT, performed by medical personnel. All images were graded by at least 2 masked investigators in a reading centre. PRIMARY OUTCOME MEASURE: Rate of successful self-measurements. SECONDARY OUTCOME MEASURES: Sensitivity and specificity of SELFF-OCT versus SD-OCT for different biomarkers and necessity for antivascular endothelial growth factor (anti-VEGF) treatment. RESULTS: In 86% of all examined eyes, OCT self-acquisition resulted in interpretable retinal OCT volume scans. In these patients, the sensitivity for detection of anti-VEGF treatment necessity was 0.94 (95% CI 0.79 to 0.99) and specificity 0.95 (95% CI 0.82 to 0.99). CONCLUSIONS: SELFF-OCT was used successfully for retinal self-examination in most patients, and it could become a valuable tool for retinal home monitoring in the future. Improvements are in progress to reduce device size and to improve handling, image quality and success rates. TRIAL REGISTRATION NUMBER: DRKS00013755, CIV-17-12-022384.


Asunto(s)
Degeneración Macular , Tomografía de Coherencia Óptica , Estudios Transversales , Humanos , Degeneración Macular/diagnóstico por imagen , Degeneración Macular/tratamiento farmacológico , Estudios Prospectivos , Autoexamen , Tomografía de Coherencia Óptica/métodos
13.
J Glaucoma ; 30(3): e108-e113, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33750749

RESUMEN

PRECIS: In eyes with intractable glaucoma, drainage devices provide long-term control of intraocular pressure also after penetrating keratoplasty (PK). There is a high incidence of corneal graft failure. PURPOSE: To compare very long-term results of eyes with glaucoma drainage device (GDD) after PK. METHODS: We retrospectively reviewed medical records of all patients who underwent GDD placement after PK at our institution between 2001 and 2017. Forty eyes of 40 patients were studied. Glaucoma outcome was assessed by postoperative intraocular pressure (IOP), number of medications, and need for further glaucoma surgery. Corneal outcome was assessed by graft rejection, failure, and visual acuity. Surgical procedures before and during the study period, and their complications were evaluated. RESULTS: The mean follow-up was 125.0±52.3 (median, 116.5) months. Twenty of 40 eyes had a follow-up of at least 10 years. The mean preoperative IOP was 34.0±8.3 (median, 32.0) mm Hg with 3.2±1.3 (median, 3.5) glaucoma medications. At last postoperative follow-up, the mean IOP decreased to 12.7±4.9 (median, 14.0) mm Hg with 1.0±1.2 (median, 0.0) glaucoma medications. GDD implantation successfully controlled glaucoma in 88%, 88%, 85%, 80%, 78%, 75%, and 70% of eyes, at 1, 2, 3, 4, 5, 7, and 10 years, respectively. At last follow-up 68% showed glaucoma success. The corneal grafts remained clear in 74%, 63%, 45%, 45%, 37%, 32%, and 26% of eyes at 1, 2, 3, 4, 5, 7, and 10 years, respectively. Only 7 corneal grafts (17.5%) remained clear at last follow-up. CONCLUSIONS: A GDD can successfully control intractable glaucoma even after a very long period of time also after PK. However, the survival of the corneal grafts is low.


Asunto(s)
Implantes de Drenaje de Glaucoma , Queratoplastia Penetrante , Córnea , Estudios de Seguimiento , Humanos , Presión Intraocular , Estudios Retrospectivos , Resultado del Tratamiento
14.
Radiat Oncol ; 15(1): 183, 2020 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-32727533

RESUMEN

BACKGROUND: To evaluate 106Ruthenium Brachytherapy in management of medium sized uveal melanoma, with emphasis on 5-year outcome and toxicity. METHODS: From April 2007 to October 2015, 39 patients with medium sized uveal melanoma were treated with 106 Ru eye plaques brachytherapy. At the time of diagnosis, the mean tumor depth was 3.7 mm (±SD:1.6 mm). The mean dose at the tumor apex was 141.4 Gy (± SD: 12.1 Gy) and 557.7 Gy (± SD: 257.3 Gy) to the sclera. RESULTS: Mean follow-up was 69.5 months (± SD: 53.8 months). Thirty-four patients (87.1%) remained free of recurrence. Twenty-six patients (66.7%) demonstrated a complete tumor regression after a median period of 12 months (3-60 mon.). By the final examination, the visual acuity of 26 patients (66.7%) was better than 20/200, and 12 patients (30.7%) had a visual acuity better than 20/40. Retinopathy was detected in 11 patients (28.2%). After treatments only one patient (5.1%) had active vascular changes by the last examination. Moderate optic neuropathy was observed in 4 patients (10.3%). Cataract development was diagnosed in 21 patients (53.8%), and 16 patients (41%) had bilateral cataract development. Special emphasis was made on patients with larger tumors. Twelve out of the 39 patients had a tumor with a depth of 5 mm or more. There was no significant difference in local control or in side effects between both groups observed. CONCLUSIONS: Our study proved 106Ru -brachytherapy to be an excellent treatment option with regard to tumor control and preservation of the visual acuity in well-selected patients. Our data suggested that this treatment is also suitable for tumors with a depth of more than 5 mm.


Asunto(s)
Braquiterapia/métodos , Melanoma/radioterapia , Rutenio/uso terapéutico , Neoplasias de la Úvea/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Braquiterapia/efectos adversos , Femenino , Humanos , Masculino , Melanoma/patología , Persona de Mediana Edad , Dosificación Radioterapéutica , Neoplasias de la Úvea/patología , Agudeza Visual
16.
Br J Ophthalmol ; 101(9): 1285-1289, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28077370

RESUMEN

BACKGROUND/AIMS: Patients with rhegmatogenous retinal detachment (RRD) who develop postoperative proliferative vitreoretinopathy (PVR) have been found to have higher preoperative laser flare values than patients with RRD who do not develop this complication. Measurement of laser flare has therefore been proposed as an objective, rapid and non-invasive method for identifying high-risk patients. The purpose of our study was to validate the use of preoperative flare values as a predictor of PVR risk in two additional patient cohorts, and to confirm the sensitivity and specificity of this method for identifying high-risk patients. METHODS: We combined data from two independent prospective studies: centre 1 (120 patients) and centre 2 (194 patients). Preoperative aqueous humour flare was measured with a Kowa FM-500 Laser Flare Meter. PVR was defined as redetachment due to the formation of traction membranes that required reoperation within 6 months of initial surgery. Logistic regression and receiver operating characteristic analysis determined whether higher preoperative flare values were associated with an increased risk of postoperative PVR. RESULTS: PVR redetachment developed in 21/314 patients (6.7%). Median flare values differed significantly between centres, therefore analyses were done separately. Logistic regression showed a small but statistically significant increase in odds with increasing flare only for centre 2 (OR 1.014; p=0.005). Areas under the receiver operating characteristic showed low sensitivity and specificity: centre 1, 0.634 (95% CI 0.440 to 0.829) and centre 2, 0.731 (95% CI 0.598 to 0.865). CONCLUSIONS: Preoperative laser flare measurements are inaccurate in discriminating between those patients with RRD at high and low risk of developing PVR.


Asunto(s)
Humor Acuoso/metabolismo , Técnicas de Diagnóstico Oftalmológico , Proteínas del Ojo/metabolismo , Desprendimiento de Retina/diagnóstico , Vitreorretinopatía Proliferativa/diagnóstico , Femenino , Humanos , Masculino , Periodo Preoperatorio , Estudios Prospectivos , Desprendimiento de Retina/metabolismo , Factores de Riesgo , Sensibilidad y Especificidad , Vitreorretinopatía Proliferativa/metabolismo
17.
Invest Ophthalmol Vis Sci ; 54(7): 4882-91, 2013 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-23800766

RESUMEN

PURPOSE: To investigate the long-term effect of macular hole surgery, foveal structure and the thickness of retinal layers were analyzed with spectral-domain optical coherence tomography (SD-OCT). The long-term postoperative course of macular thickness and best-corrected visual acuity (BCVA) were followed. METHODS: In a retrospective cohort study, SD-OCT scans were obtained from the horizontal midline in 51 eyes 54±20 months postoperatively and from 30 control eyes. Retinal layer thickness was measured with a manual segmentation procedure aided by a customized computer program. BCVA was followed and macular thickness was quantified over time with the time-domain (TD) OCT Fast Macular Thickness program for up to 91 months. RESULTS: Median foveal thickness between the outer plexiform and ganglion cell layers was greater than normal while that of the other retinal layers was normal. The median foveal shape remained slightly distorted. The postoperative decrease of central macular thickness toward normal values was delayed to 28 months postoperatively. Nasal macular thickness was decreased to normal at 6 months while superior, temporal, and inferior macular thickness was decreased to normal at 1 to 2 months postoperatively. Preoperative mean BCVA was 20/100±3 lines. Postoperatively, mean BCVA was 20/44±2 lines at 3 to 6 months, 20/40±2 lines at 1 year, 20/32±2 lines at 2 years, and 20/28±1 line after a mean follow-up period of 54±20 months. CONCLUSIONS: Long-term postoperatively, the median thickness of retinal layers remains slightly thickened between the outer plexiform and the ganglion cell layer. The process of gradual recovery may continue for several years after macular hole surgery.


Asunto(s)
Perforaciones de la Retina/cirugía , Agudeza Visual/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fóvea Central , Humanos , Mácula Lútea , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Células Ganglionares de la Retina/patología , Perforaciones de la Retina/patología , Perforaciones de la Retina/fisiopatología , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Vitrectomía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA