1.
JACC Clin Electrophysiol ; 3(13): 1487-1498, 2017 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-29759829

RESUMEN

OBJECTIVES: The primary objective was to assess the acute and 3-month performance of the modular antitachycardia pacing (ATP)-enabled leadless pacemaker (LP) and subcutaneous implantable cardioverter-defibrillator (S-ICD) system, particularly device-device communication and ATP delivery. BACKGROUND: Transvenous pacemakers and implantable cardioverter-defibrillators (ICDs) have considerable rates of lead complications. We examined the next step in multicomponent leadless cardiac rhythm management: feasibility of pacing (including ATP) by a LP, commanded by an implanted S-ICD through wireless, intrabody, device-device communication. METHODS: The combined modular cardiac rhythm management therapy system of the LP and S-ICD prototypes was evaluated in 3 animal models (ovine, porcine, and canine) both in acute and chronic (90 days) experiments. LP performance, S-ICD to LP communication, S-ICD and LP rhythm discrimination, and ATP delivery triggered by the S-ICD were tested. RESULTS: The LP and S-ICD were successfully implanted in 98% of the animals (39 of 40). Of the 39 animals, 23 were followed up for 90 days post-implant. LP performance was adequate and exhibited appropriate VVI behavior during the 90 days of follow-up in all tested animals. Unidirectional communication between the S-ICD and LP was successful in 99% (398 of 401) of attempts, resulting in 100% ATP delivery by the LP (10 beats at 81% of the coupling interval). Adequate S-ICD sensing was observed during normal sinus rhythm, LP pacing, and ventricular tachycardia/ventricular fibrillation. CONCLUSIONS: This study presents the preclinical acute and chronic performance of the combined function of an ATP-enabled LP and S-ICD. Appropriate VVI functionality, successful wireless device-device communication, and ATP delivery were demonstrated by the LP. Clinical studies on safety and performance are needed.


Asunto(s)
Estimulación Cardíaca Artificial/estadística & datos numéricos , Electrodos Implantados/tendencias , Equipos y Suministros/normas , Taquicardia Ventricular/terapia , Animales , Comunicación , Desfibriladores Implantables/efectos adversos , Desfibriladores Implantables/estadística & datos numéricos , Perros , Electrocardiografía , Diseño de Equipo , Equipos y Suministros/estadística & datos numéricos , Modelos Animales , Evaluación de Resultado en la Atención de Salud , Marcapaso Artificial/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Marcapaso Artificial/tendencias , Estudios Prospectivos , Ajuste de Prótesis/métodos , Ovinos , Tejido Subcutáneo , Porcinos , Taquicardia Ventricular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA