Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Pediatr Crit Care Med ; 23(10): 822-830, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35830709

RESUMEN

OBJECTIVES: Currently, there are no prediction tools available to identify patients at risk of needing high-complexity care following cardiac catheterization for congenital heart disease. We sought to develop a method to predict the likelihood a patient will require intensive care level resources following elective cardiac catheterization. DESIGN: Prospective single-center study capturing important patient and procedural characteristics for predicting discharge to the ICU. Characteristics significant at the 0.10 level in the derivation dataset (July 1, 2017 to December 31, 2019) were considered for inclusion in the final multivariable logistic regression model. The model was validated in the testing dataset (January 1, 2020 to December 31, 2020). The novel pre-procedure cardiac status (PCS) feature, collection started in January 2019, was assessed separately in the final model using the 2019 through 2020 dataset. SETTING: Tertiary pediatric heart center. PATIENTS: All elective cases coming from home or non-ICU who underwent a cardiac catheterization from July 2017 to December 2020. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 2,192 cases were recorded in the derivation dataset, of which 11% of patients ( n = 245) were admitted to the ICU, while 64% ( n = 1,413) were admitted to a medical unit and 24% ( n = 534) were discharged home. In multivariable analysis, the following predictors were identified: 1) weight less than 5 kg and 5-9.9 kg, 2) presence of systemic illness, 3) recent cardiac intervention less than 90 days, and 4) ICU Admission Tool for Congenital Heart Catheterization case type risk categories (1-5), with C -statistics of 0.79 and 0.76 in the derivation and testing cohorts, respectively. The addition of the PCS feature fit into the final model resulted in a C -statistic of 0.79. CONCLUSIONS: The creation of a validated pre-procedural risk prediction model for ICU admission following congenital cardiac catheterization using a large volume, single-center, academic institution will improve resource allocation and prediction of capacity needs for this complex patient population.


Asunto(s)
Cateterismo Cardíaco , Cardiopatías Congénitas , Cateterismo Cardíaco/efectos adversos , Niño , Cardiopatías Congénitas/epidemiología , Cardiopatías Congénitas/cirugía , Humanos , Unidades de Cuidados Intensivos , Modelos Logísticos , Admisión del Paciente , Estudios Prospectivos , Factores de Riesgo
2.
Pediatr Cardiol ; 43(3): 596-604, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34743224

RESUMEN

The objective of this study was to evaluate the impact of the regular introduction of new technologies into interventional cardiac catheterization procedures, in this case new atrial septal defect (ASD) closure devices, while conducting a multi-center collaborative initiative to reduce radiation usage during all procedures. Data were collected prospectively by 8 C3PO institutions between January 1, 2014 and December 31, 2017 for ASD device closure procedures in the cardiac catheterization lab during a quality improvement (QI) initiative aimed at reducing patient radiation exposure. Radiation exposure was measured in dose area product per body weight (µGy*m2/kg). Use of proposed practice change strategies at the beginning and end of the QI intervention period was assessed. Radiation exposure was summarized by institution and by initial type of device used for closure. This study included 602 ASD device closures. Without changes in patient characteristics, total fluoroscopy duration, or number of digital acquisitions, median radiation exposure decreased from 37 DAP/kg to 14 DAP/kg from 2014 to 2017. While all individual centers decreased overall median DAP/kg, the use of novel devices for ASD closure correlated with a temporary period of worsening institutional radiation exposure and increased fluoroscopy time. The introduction of new ASD closure devices resulted in increased radiation exposure during a QI project designed to reduce radiation exposure. Therefore, outcome assessment must be contextualized in QI projects, hospital evaluation, and public reporting, to acknowledge the expected variation during innovation and introduction of novel therapies.


Asunto(s)
Defectos del Tabique Interatrial , Exposición a la Radiación , Dispositivo Oclusor Septal , Cateterismo Cardíaco/métodos , Fluoroscopía/métodos , Defectos del Tabique Interatrial/cirugía , Humanos , Mejoramiento de la Calidad , Dosis de Radiación , Exposición a la Radiación/prevención & control , Estudios Retrospectivos , Resultado del Tratamiento
3.
Pediatr Cardiol ; 40(2): 445-453, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30506273

RESUMEN

To stratify diverse procedure types into categories with similar radiation exposure in cardiac catheterization for congenital heart disease. Radiation exposures for a comprehensive list of specific procedure types and stratification of outcomes based on radiation risk are not currently available. Data between January 2014 and December 2015 were collected on all cases performed at sites participating in C3PO-QI (Congenital Cardiac Catheterization Outcomes Project-Quality Improvement Initiative) and 9 centers were included. Using expert consensus, 40 unique procedure types were defined by diagnostic characteristics or the intervention(s) performed, and dose area product (DAP) per kilogram of body weight (µGy × m2/kg) was summarized. Using empiric and consensus methods, three radiation risk categories were created. A total of 11,735 cases were included for analysis. Thirteen (n = 7918) procedure types with median DAP/kg < 100 were categorized in the low radiation exposure category (median DAP/kg 39). The medium exposure category (n = 1807) consisted of 16 procedure types with median DAP/kg values ranging 100 to < 200 (overall median DAP/kg 131). Finally, the high radiation exposure category (n = 1073) consisted of 11 procedure types with median DAP/kg ≥ 200 (overall median DAP/kg of 231). The radiation exposure risk categories created in this multi-center dataset are a critical step towards the development of a robust risk adjustment methodology for radiation exposure in catheterization for congenital heart disease.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Fluoroscopía/efectos adversos , Cardiopatías Congénitas/cirugía , Exposición a la Radiación , Radiografía Intervencional/efectos adversos , Adolescente , Niño , Preescolar , Consenso , Humanos , Lactante , Estudios Prospectivos , Mejoramiento de la Calidad , Dosis de Radiación , Medición de Riesgo/métodos , Factores de Riesgo , Adulto Joven
4.
Circ Cardiovasc Interv ; 17(3): e012834, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38258562

RESUMEN

BACKGROUND: Current metrics used to adjust for case mix complexity in congenital cardiac catheterization are becoming outdated due to the introduction of novel procedures, innovative technologies, and expanding patient subgroups. This study aims to develop a risk adjustment methodology introducing a novel, clinically meaningful adverse event outcome and incorporating a modern understanding of risk. METHODS: Data from diagnostic only and interventional cases with defined case types were collected for patients ≤18 years of age and ≥2.5 kg at all Congenital Cardiac Catheterization Project on Outcomes participating centers. The derivation data set consisted of cases performed from 2014 to 2017, and the validation data set consisted of cases performed from 2019 to 2020. Severity level 3 adverse events were stratified into 3 tiers by clinical impact (3a/b/c); the study outcome was clinically meaningful adverse events, severity level ≥3b (3bc/4/5). RESULTS: The derivation data set contained 15 224 cases, and the validation data set included 9462 cases. Clinically meaningful adverse event rates were 4.5% and 4.2% in the derivation and validation cohorts, respectively. The final risk adjustment model included age <30 days, Procedural Risk in Congenital Cardiac Catheterization risk category, and hemodynamic vulnerability score (C statistic, 0.70; Hosmer-Lemeshow P value, 0.83; Brier score, 0.042). CONCLUSIONS: CHARM II (Congenital Heart Disease Adjustment for Risk Method II) risk adjustment methodology allows for equitable comparison of clinically meaningful adverse events among institutions and operators with varying patient populations and case mix complexity performing pediatric cardiac catheterization.


Asunto(s)
Cateterismo Cardíaco , Cardiopatías Congénitas , Niño , Humanos , Lactante , Factores de Riesgo , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/terapia , Hemodinámica , Ajuste de Riesgo/métodos
5.
J Am Heart Assoc ; 11(1): e022832, 2022 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-34935425

RESUMEN

Background Advancements in the field, including novel procedures and multiple interventions, require an updated approach to accurately assess patient risk. This study aims to modernize patient hemodynamic and procedural risk classification through the creation of risk assessment tools to be used in congenital cardiac catheterization. Methods and Results Data were collected for all cases performed at sites participating in the C3PO (Congenital Cardiac Catheterization Project on Outcomes) multicenter registry. Between January 2014 and December 2017, 23 119 cases were recorded in 13 participating institutions, of which 88% of patients were <18 years of age and 25% <1 year of age; a high-severity adverse event occurred in 1193 (5.2%). Case types were defined by procedure(s) performed and grouped on the basis of association with the outcome, high-severity adverse event. Thirty-four unique case types were determined and stratified into 6 risk categories. Six hemodynamic indicator variables were empirically assessed, and a novel hemodynamic vulnerability score was determined by the frequency of high-severity adverse events. In a multivariable model, case-type risk category (odds ratios for category: 0=0.46, 1=1.00, 2=1.40, 3=2.68, 4=3.64, and 5=5.25; all P≤0.005) and hemodynamic vulnerability score (odds ratio for score: 0=1.00, 1=1.27, 2=1.89, and ≥3=2.03; all P≤0.006) remained independent predictors of patient risk. Conclusions These case-type risk categories and the weighted hemodynamic vulnerability score both serve as independent predictors of patient risk for high-severity adverse events. This contemporary procedure-type risk metric and weighted hemodynamic vulnerability score will improve our understanding of patient and procedural outcomes.


Asunto(s)
Cardiopatías Congénitas , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/etiología , Cardiopatías Congénitas/terapia , Hemodinámica , Humanos , Lactante , Oportunidad Relativa , Sistema de Registros , Medición de Riesgo , Factores de Riesgo
6.
Circ Cardiovasc Interv ; 13(5): e008172, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32408819

RESUMEN

BACKGROUND: The C3PO-QI (Congenital Cardiac Catheterization Project on Outcomes - Quality Improvement), a multicenter registry launched in 2015, instituted quality improvement (QI) initiatives to reduce patient radiation exposure. Through regular collaboration, this initiative would allow for harmony among active participants, maximizing efforts and efficiency at achieving radiation best practices. This study sought to report these efforts with a detailed methodology for which institutions can target initiatives, reducing radiation exposure, and increasing patient safety. METHODS: Data were collected prospectively by 8 C3PO-QI institutions between January 1, 2015 and December 31, 2017. Radiation exposure was measured in dose area product per body weight (dose area product/kg; µGy*m2/kg) and reported by expected radiation exposure categories (REC) and institution for 40 published unique procedure types. Targeted interventions addressing selected strategic domains for radiation reduction were implemented in the pediatric catheterization labs of the C3PO-QI institutions. RESULTS: The study consisted of 15 257 unique cases. Median exposure (dose area product/kg) was decreased by 30% for all procedures. Dose area product/kg was reduced in all 3 REC, with the greatest improvement observed in REC I (REC I, -37%; REC II, -23%; REC III, -27%). Although the baseline radiation exposures and exact percent decrease varied across all C3PO-QI sites, each institution demonstrated improvements in radiation dose over time. These improvements occurred with the implementation of institution-specific QI interventions accelerated by participation in the C3PO-QI multicenter collaborative. CONCLUSIONS: Substantial radiation dose reductions can be achieved using targeted QI methodology and interventions. Participation in a multicenter QI collaborative may accelerate improvement across all centers due to enhanced engagement and shared learning between sites.


Asunto(s)
Cateterismo Cardíaco , Angiografía Coronaria , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/terapia , Dosis de Radiación , Exposición a la Radiación/prevención & control , Traumatismos por Radiación/prevención & control , Protección Radiológica , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Angiografía Coronaria/efectos adversos , Bases de Datos Factuales , Femenino , Disparidades en Atención de Salud , Humanos , Lactante , Masculino , Seguridad del Paciente , Estudios Prospectivos , Mejoramiento de la Calidad , Indicadores de Calidad de la Atención de Salud , Exposición a la Radiación/efectos adversos , Traumatismos por Radiación/etiología , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Adulto Joven
7.
J Sep Sci ; 31(6-7): 1092-9, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18381686

RESUMEN

Candidate kairomones of ornithophilic mosquito species are reported from GC/MS analysis of compounds from the skin on the back, the feet, and feathers from the back of White Leghorn chickens (Gallus gallus domesticus). Hexane and ether extracts of chicken feathers differ significantly in attractiveness of Culex spp. mosquitoes. The active (hexane) extracts contained an abundance of alcohols, ketones, and diones. The inactive (ether) extracts contained aldehydes, which also were in the hexane extracts. Analysis of hexane extracts from chicken feet, skin, and feathers demonstrated the qualitative similarity in the compounds collected with subtle differences observed in the quantitative amounts of these compounds. Aldehydes and carboxylic acids were detected in a concentrated ether extract of feathers in quantitatively similar ratios within each compound class for the corresponding series of C(6)-C(9 )aldehydes and acids.


Asunto(s)
Factores Biológicos/química , Factores Biológicos/aislamiento & purificación , Pollos , Culicidae/efectos de los fármacos , Plumas/química , Piel/química , Aldehídos/química , Animales , Factores Biológicos/farmacología , Pollos/anatomía & histología , Culicidae/clasificación , Volatilización
8.
J Chromatogr A ; 1160(1-2): 306-10, 2007 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-17568593

RESUMEN

Mosquitoes transmit pathogens that result in diseases harmful to human, livestock, and wildlife hosts. Numerous measures can be used to reduce insect-borne disease risk to humans, and one approach is the use of topical repellents to prevent host-seeking arthropods from taking a blood meal. A current emphasis in the development of new repellents is that they be safe. Therefore, natural products sources are increasingly being explored. Compounds from plants of the mint family (Lamiaceae) have been demonstrated to be insect repellents. This study examines compounds from Etonia rosemary (Conradina etonia) to identify compounds for examination as insect repellents. Samples of Etonia rosemary were passively extracted with hexane, dichloromethane, and methanol and analyzed by GC/MS. This extraction method was chosen to eliminate thermal degradation of plant components that can occur during the distillation procedure. Additional headspace volatile compounds from this plant were identified using microscale purge-and-trap GC/MS. A variety of terpenes, terpenic alcohols, ketones, and aldehydes were identified in the extracts with terpenes and short-chained aldehydes detected in greatest abundance.


Asunto(s)
Compuestos Orgánicos/análisis , Rosmarinus/química , Cromatografía de Gases y Espectrometría de Masas , Extractos Vegetales/química , Volatilización
9.
J Chromatogr A ; 1139(2): 279-84, 2007 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-17141254

RESUMEN

House flies are a ubiquitous insect that have the potential to spread many diseases to humans and livestock. Managing house fly populations is accomplished by having desirable baits, traps, and killing agents. Most house fly baits are designed for outdoor use or limited indoor use, and have a foul odor that is not conducive to food preparatory and dining areas. Blackstrap molasses has long been used as a house fly bait, but it is sticky and viscous, making it difficult to handle. This study sought to identify compounds present in blackstrap molasses that might be attractive to house flies, and therefore, provide the public with an indoor bait that does not have an offensive smell and is easy to handle. Indoor bioassays with house flies using 50% blackstrap molasses diluted in deionized water, a hexane extract of blackstrap molasses, and deionized water, elicited 86.2%, 70.6%, and 13.8% responses, respectively. Hexane and diethyl ether extracts of blackstrap molasses produced a large number of compounds with widely differing organic structures including substituted phenols, nitrogen and oxygen heterocycles, carboxylic acids, and many other organic compounds.


Asunto(s)
Melaza/análisis , Aceites Volátiles/análisis , Control Biológico de Vectores , Feromonas/análisis , Animales , Moscas Domésticas/efectos de los fármacos , Control de Insectos , Aceites Volátiles/farmacología , Feromonas/farmacología
10.
Biophys Chem ; 196: 100-8, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25451684

RESUMEN

As compounds are optimized for greater potency during pharmaceutical discovery, their aqueous solubility often decreases, making them less viable as orally-administered drugs. To investigate whether potency and insolubility share a common origin, we examined the structural and thermodynamic properties of telaprevir, a sparingly soluble inhibitor of hepatitis C virus protease. Comparison of the hydrogen bond motifs in crystalline telaprevir with those present in the protease-telaprevir complex revealed striking similarities. Additionally, the thermodynamics of telaprevir dissolution closely resembles those of protein-ligand dissociation. Together, these findings point to a common origin of potency and insolubility rooted in particular amide-amide hydrogen bond patterns. The insolubility of telaprevir is shown by computational analysis to be caused by interactions in the crystal, not unfavorable hydrophobic hydration. Accordingly, competing out the particular amide-amide hydrogen bond motifs in crystalline telaprevir with 4-hydroxybenzoic acid yielded a co-crystalline solid with excellent aqueous dissolution and oral absorption. The analysis suggests a generalizable approach for identifying drug candidate compounds that either can or cannot be rendered orally bioavailable by alteration of their crystalline solid phases, in an approach that provides a pragmatic way to attain substantial enhancements in the success rate of drug discovery and development.


Asunto(s)
Hepacivirus/enzimología , Inhibidores de Proteasas/química , Proteínas no Estructurales Virales/antagonistas & inhibidores , Amidas/química , Enlace de Hidrógeno , Oligopéptidos/química , Oligopéptidos/metabolismo , Inhibidores de Proteasas/metabolismo , Unión Proteica , Solubilidad , Temperatura , Termodinámica , Proteínas no Estructurales Virales/metabolismo
11.
Environ Toxicol Chem ; 22(1): 205-13, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12503766

RESUMEN

This study evaluated the effects of bleached and unbleached kraft mill effluent on reproductive success of largemouth bass (Micropterus salmoides). Bass were exposed to effluent concentrations (0, 10, 20, 40, or 80%) for 28 and 56 d. Parameters measured included hepatosomatic index (HSI) and gonadosomatic index (GSI) and plasma concentrations of 17beta-estradiol (E2), 11-ketotestosterone (11-KT), and vitellogenin (VTG). At the end of the 56-d period, bass were moved to hatchery ponds to evaluate spawning success. Spawning mats with eggs either were brought indoors for evaluation of fecundities, hatchabilities, and egg and fry size (measured at age 3 d), or were left in ponds and fry number and size recorded (average age of 14 d). Effluent exposure was verified by measuring resin acids (isopimaric, abietic. and dehydroabietic acids) in bile. Compared to controls, exposed bass had greater concentrations of resin acids in bile. In general, exposed females had lower concentrations of E2 and VTG (> or = 20% effluent), whereas males had lower concentrations of 11-KT (> or = 20% effluent) and increased E2 (> or = 20% effluent). The HSI values increased in females (> or = 10% effluent), and GSI values decreased in both sexes (> or = 40% effluent). Fecundity, egg size, and hatchability did not differ across treatments, but an increase in the frequency of fry abnormalities and a decrease in fry weights was observed at effluent exposures of 40% and higher. However, results from the pond study, revealed a significant reduction in fry growth and survival (> or = 10%). This decline may have been caused by an increased frequency of deformities, in conjunction with alterations of growth. These changes could have resulted from alterations in egg quality because of failure of parental reproductive systems, from acute embryo toxicity after translocation of contaminants from the mother to the developing embryo, or from both.


Asunto(s)
Lubina/fisiología , Residuos Industriales/efectos adversos , Reproducción/efectos de los fármacos , Testosterona/análogos & derivados , Contaminantes Químicos del Agua/efectos adversos , Animales , Anomalías Congénitas/etiología , Anomalías Congénitas/veterinaria , Desarrollo Embrionario , Estradiol/sangre , Femenino , Fertilidad , Larva/crecimiento & desarrollo , Masculino , Papel , Testosterona/sangre , Vitelogeninas/sangre
12.
Environ Toxicol Chem ; 22(1): 214-8, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12503767

RESUMEN

Water samples were collected on three dates at 24 sites influenced by effluent from Georgia-Pacific's Palatka Pulp and Paper Mill Operation, a bleached and unbleached kraft mill near Palatka, Florida, USA. The sampling sites were located within the mill retention ponds, Rice Creek, and the St. John's River. Samples were analyzed by gas chromatography-mass spectrometry for abietic, dehydroabietic, and isopimaric acids, all of which are potentially toxic by-products of pulp production. Isopimaric acid concentrations greater than 12 mg/L were measured at the mill's effluent outfall but were less than 20 microg/L at the end of Rice Creek. This result indicates that the waters of Rice Creek provide dilution or conditions conducive for degradation or sorption of these compounds. Large differences in resin acid concentrations were observed between sampling events. In two sampling events, the maximum observed concentrations were less than 2 mg/L for each analyte. In a third sampling event, all of the compounds were detected at concentrations greater than 10 mg/L. Data from the three sample dates showed that resin acid concentrations were below 20 microg/L before the confluence of Rice Creek and the St. John's River in all cases.


Asunto(s)
Abietanos , Ácidos Carboxílicos/análisis , Diterpenos/análisis , Residuos Industriales/análisis , Fenantrenos/análisis , Contaminantes Químicos del Agua/análisis , Monitoreo del Ambiente , Florida , Cromatografía de Gases y Espectrometría de Masas , Papel , Abastecimiento de Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA