Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Shoulder Elbow Surg ; 33(7): 1503-1511, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38182017

RESUMEN

BACKGROUND: Reproducible methods for determining adequate bone densities for stemless anatomic total shoulder arthroplasty (aTSA) are currently lacking. The purpose of this study was to evaluate the utility of preoperative computed tomography (CT) imaging for assessing the bone density of the proximal humerus for supportive differentiation in the decision making for stemless humeral component implantation. It was hypothesized that preoperative 3-dimensional (3-D) CT bone density measures provide objective classifications of the bone quality for stemless aTSA. METHODS: A 3-part study was performed that included the analysis of cadaveric humerus CT scans followed by retrospective application to a clinical cohort and classification with a machine learning model. Thirty cadaveric humeri were evaluated with clinical CT and micro-CT (µCT) imaging. Phantom-calibrated CT data were used to extract 3-D regions of interest and defined radiographic scores. The final image processing script was applied retrospectively to a clinical cohort (n = 150) that had a preoperative CT and intraoperative bone density assessment using the "thumb test," followed by placement of an anatomic stemmed or stemless humeral component. Postscan patient-specific calibration was used to improve the functionality and accuracy of the density analysis. A machine learning model (Support vector machine [SVM]) was utilized to improve the classification of bone densities for a stemless humeral component. RESULTS: The image processing of clinical CT images demonstrated good to excellent accuracy for cylindrical cancellous bone densities (metaphysis [ICC = 0.986] and epiphysis [ICC = 0.883]). Patient-specific internal calibration significantly reduced biases and unwanted variance compared with standard HU CT scans (P < .0001). The SVM showed optimized prediction accuracy compared with conventional statistics with an accuracy of 73.9% and an AUC of 0.83 based on the intraoperative decision of the surgeon. The SVM model based on density clusters increased the accuracy of the bone quality classification to 87.3% with an AUC of 0.93. CONCLUSIONS: Preoperative CT imaging allows accurate evaluation of the bone densities in the proximal humerus. Three-dimensional regions of interest, rescaling using patient-specific calibration, and a machine learning model resulted in good to excellent prediction for objective bone quality classification. This approach may provide an objective tool extending preoperative selection criteria for stemless humeral component implantation.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Densidad Ósea , Húmero , Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Masculino , Femenino , Húmero/diagnóstico por imagen , Húmero/cirugía , Anciano , Persona de Mediana Edad , Cadáver , Cuidados Preoperatorios/métodos , Aprendizaje Automático , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Anciano de 80 o más Años
2.
J Shoulder Elbow Surg ; 33(4): e175-e184, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37652214

RESUMEN

BACKGROUND: To reduce hardware-related complications in coracoid graft fixation to the anterior aspect of the glenoid, a metal-free Latarjet technique was recently introduced. The aim of this study was to compare the primary stability of a classic Latarjet procedure with 2 metal screws to a novel metal-free, all-suture cerclage method. It is hypothesized that fixation of the coracoid graft with 2 malleolar screws will provide higher primary stability compared with an all-suture cerclage technique. METHODS: This biomechanical in vitro study was conducted on 12 fresh-frozen cadaveric shoulders (6 matched pairs) with a mean donor age of 80 years (range, 67-89 years). Coracoid graft fixation was performed using a recently introduced all-suture cerclage technique (group A) or a classic Latarjet technique with two 4.5-mm malleolar screws (group B). The conjoint tendon was loaded with a static force of 10 N to simulate the sling effect. Graft loading with a probe head consisted of 6 ascending load levels (10-50 N, 10-100 N, 10-150 N, 10-200 N, 10-250 N, and 10-300 N) with 100 cycles each at 1 Hz. Relative motion of the bone graft to the glenoid was measured using an optic 3-dimensional system. RESULTS: While loading the conjoint tendon with 10 N, no difference in mean displacement of the bone-graft was found between both groups (P = .144). During cyclic loading, a significant difference in relative displacement for both groups was already detected in load level 1 (group A: 2398.8 µm vs. group B: 125.7 µm; P = .024), and this trend continued with the following load levels (P < .05). DISCUSSION AND CONCLUSION: The study demonstrated that the innovative metal-free, all-suture cerclage fixation technique results in higher micromotion than the classic coracoid graft fixation with 2 malleolar screws. According to the present biomechanical investigation, shoulders treated with a metal-free all-suture cerclage technique might need adapted rehabilitation protocols to protect the construct and allow for graft healing.


Asunto(s)
Bursitis , Inestabilidad de la Articulación , Luxación del Hombro , Articulación del Hombro , Humanos , Anciano , Anciano de 80 o más Años , Articulación del Hombro/cirugía , Trasplante Óseo , Escápula/cirugía , Luxación del Hombro/cirugía , Suturas , Fenómenos Biomecánicos , Inestabilidad de la Articulación/cirugía
3.
Artículo en Inglés | MEDLINE | ID: mdl-39008078

RESUMEN

BACKGROUND: The lateralization shoulder angle (LSA) and distalization shoulder angle (DSA) are used to reproducibly measure lateralization and distalization after reverse shoulder arthroplasty (RSA). However, LSA and DSA may not offer a precise measurement of humeral lateralization and distalization and this relationship has not been explored. The aim of this study was to evaluate the validity of these measurements and to propose new measurement methods to estimate implant lateralization and distalization. METHODS: 3D models were constructed from computed tomography (CT) scans of 30 patients using a software platform. For each patient 24 different RSA modifications were created, resulting in 720 different RSA configurations. For each configuration LSA and DSA angles as well as lateralization and distalization distances were measured. Moreover, for each configuration two new measurements were done: the lateralization index (LI) and distalization index (DI). Correlations of the lateralization and distalization parameters were evaluated between measurements. RESULTS: Weak correlations were founded between LSA and lateralization (r = 0.36, p < 0.01), whereas moderate correlations were observed between LI and lateralization (r = 0.72, p < 0.01). No significant correlations were found between DSA and distalization (r = 0.17, p = 0.113). In contrast, moderate correlations were identified between DI and distalization (r = 0.69, p < 0.01). CONCLUSION: LI and DI are more reliable methods to estimate implant lateralization and distalization compared to angular radiographic measurements. However, the prognostic significance in predicting clinical outcomes after RSA remains unknown.

4.
Arch Orthop Trauma Surg ; 144(2): 663-672, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38010377

RESUMEN

INTRODUCTION: To preserve humeral bone during RTSA, stems have been made shorter and cement avoided whenever possible. However, with the increased use of uncemented RTSA, a phenomenon comparable to the stress shielding of the hip has been described for the proximal humerus. The aim of this study was to investigate the influence of stem length and width on proximal humeral bone resorption after primary uncemented RTSA. MATERIALS AND METHODS: The prospective shoulder arthroplasty database of our institution was reviewed for all primary uncemented RTSAs from 2017 to 2020 in osteoarthritis and cuff tear arthropathy cases with > 2-year follow-up. We compared the clinical and the radiographic 2-year outcome of the short and standard length stems of the same prosthesis design. This allowed us to assess the effects of stem length and width with regard to stress shielding. Furthermore, we defined a cut-off value for the filling ratios to prevent stress shielding. RESULTS: Fifty patients were included in the analysis, nineteen were in the short stem group (SHORT) and thirty-one in the standard stem group (STANDARD). After 2 years, SHORT showed a relative Constant Score of 91.8% and STANDARD of 98.3% (p = 0.256). Stress shielding was found in 4 patients (21%) in SHORT and in 16 patients (52%) in STANDARD (p = 0.03); it occurred more frequently in patients with higher humeral filling ratios (p < 0.05). The calculated cut-off to prevent stress shielding was 0.7 (± 0.03) for the metaphyseal and distal filling ratio. CONCLUSION: While short and standard stems for RTSA have good results after 2 years, we found a significant negative effect of higher length and width of the stem with regard to stress shielding. Even though the clinical effects of stress shielding have to be assessed, short stems should be chosen with a filling ratio at the metaphyseal and distal position below 0.7. LEVEL OF EVIDENCE (A RETROSPECTIVE CASE-CONTROL STUDY): III.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Estudios de Casos y Controles , Resultado del Tratamiento , Húmero/cirugía
5.
Arch Orthop Trauma Surg ; 143(7): 3735-3741, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35963979

RESUMEN

INTRODUCTION: Three-dimensional surgical planning software provides virtual reconstructions of the shoulder with automated joint indices for a preoperative case assessment. The aim of this single center study was to evaluate the concordance between the preoperatively selected humeral components and the final implants used in shoulder arthroplasty. METHODS: 129 cases who had undergone anatomic (n = 16) or reverse shoulder arthroplasty (n = 117) using the same type of uncemented short stem implant and were included for review in this study. The type of arthroplasty, stem size, stem inclination, tray-offset and liner-thickness were noted preoperatively and compared to the final implant specifications used in surgery. RESULTS: The type of arthroplasty matched the surgical plan in 99.2% of cases, as one case was converted from RSA to TSA. The concordance of planned to implanted stem size was 44.2% and the planned size was in range of one adjacent size in 87.6% of cases. Stem inclination in TSA matched the surgical plan in 50% of cases. Tray offset in RSA was predicted correctly in 65% and liner-thickness matched the surgical plan in 98.3% of cases. CONCLUSION: Despite a low degree of concordance of planned to implanted stem sizes of 44.2%, the choice of stem size was found to be in range of one adjacent size in 87.6% of cases. Further investigations of other contributing factors are necessary to increase the accuracy of the preoperative selection of humeral implants. LEVEL OF EVIDENCE: level IV, retrospective case study.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Estudios Retrospectivos , Programas Informáticos , Diseño de Prótesis
6.
Arch Orthop Trauma Surg ; 143(4): 1833-1839, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35174410

RESUMEN

INTRODUCTION: Radiographic stress shielding is a common finding in uncemented convertible short-stem shoulder arthroplasty (UCSSSA). The distal filling ratio (DFR) has been described as a predictor for the occurrence of stress shielding. A DFR > 70% was mentioned as a risk factor for the occurrence of stress shielding for some UCSSSA. However, measurements were only performed on conventional radiographs and no validation exists for 3D automated planning tools. METHODS: DFR was manually measured on postoperative true ap radiographs of 76 shoulder arthroplasties using a standardized protocol and were compared to preoperative CT scans with an automated calculation of the DFR after virtual implantation of the stem. RESULTS: The mean DFR measured on X-rays was 75.9% (SD = 8.7; 95% CI = 74-78) vs. 78.9% (SD = 9.1; 95% CI = 76.8-83) automatically measured on CT scans. This difference was significant (p < 0.001). In 7 out of 76 cases (9%) the difference between manual measurement on radiographs and computerized measurement on CT scans was > 10%. CONCLUSION: Manual measurement of the DFR is underestimated on conventional radiographs compared to automated calculation on CT scans be a mean of 3%. Therefore, automated measurement of the DFR on CT scans seems to be beneficial, especially in cases with osteopenic cortices. Manual measurement of the DFR on conventional ap radiographs in cases without CT scans, however, is still a viable alternative. LEVEL OF EVIDENCE: Level IV, retrospective study.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Resultado del Tratamiento , Estudios Retrospectivos , Radiografía , Tomografía Computarizada por Rayos X/métodos , Articulación del Hombro/cirugía
7.
Clin Orthop Relat Res ; 480(3): 619-631, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34669618

RESUMEN

BACKGROUND: Component selection and placement in reverse total shoulder arthroplasty (RTSA) is still being debated. Recently, scapulothoracic orientation and posture have emerged as relevant factors when planning an RTSA. However, the degree to which those parameters may influence ROM and whether modifiable elements of implant configuration may be helpful in improving ROM among patients with different postures have not been thoroughly studied, and modeling them may be instructive. QUESTIONS/PURPOSES: Using a dedicated expansion of a conventional preoperative planning software, we asked: (1) How is patient posture likely to influence simulated ROM after virtual RTSA implantation? (2) Do changes in implant configuration, such as humeral component inclination and retrotorsion, or glenoid component size and centricity improve the simulated ROM after virtual RTSA implantation in patients with different posture types? METHODS: In a computer laboratory study, available whole-torso CT scans of 30 patients (20 males and 10 females with a mean age of 65 ± 17 years) were analyzed to determine the posture type (Type A, upright posture, retracted scapulae; Type B, intermediate; Type C, kyphotic posture with protracted scapulae) based on the measured scapula internal rotation as previously described. The measurement of scapular internal rotation, which defines these posture types, was found to have a high intraclass correlation coefficient (0.87) in a previous study, suggesting reliability of the employed classification. Three shoulder surgeons each independently virtually implanted a short, curved, metaphyseal impaction stem RTSA in each patient using three-dimensional (3D) preoperative surgical planning software. Modifications based on the original component positioning were automatically generated, including different humeral component retrotorsion (0°, 20°, and 40° of anatomic and scapular internal rotation) and neck-shaft angle (135°, 145°, and 155°) as well as glenoid component configuration (36-mm concentric, 36-mm eccentric, and 42-mm concentric), resulting in 3720 different RTSA configurations. For each configuration, the maximum potential ROM in different planes was determined by the software, and the effect of different posture types was analyzed by comparing subgroups. RESULTS: Irrespective of the RTSA implant configuration, the posture types had a strong effect on the calculated ROM in all planes of motion, except for flexion. In particular, simulated ROM in patients with Type C compared with Type A posture demonstrated inferior adduction (median 5° [interquartile range -7° to 20°] versus 15° [IQR 7° to 22°]; p < 0.01), abduction (63° [IQR 48° to 78°] versus 72° [IQR 63° to 82°]; p < 0.01), extension (4° [IQR -8° to 12°] versus 19° [IQR 8° to 27°]; p < 0.01), and external rotation (7° [IQR -5° to 22°] versus 28° [IQR 13° to 39°]; p < 0.01). Lower retrotorsion and a higher neck-shaft angle of the humeral component as well as a small concentric glenosphere resulted in worse overall ROM in patients with Type C posture, with severe restriction of motion in adduction, extension, and external rotation to below 0°. CONCLUSION: Different posture types affect the ROM after simulated RTSA implantation, regardless of implant configuration. An individualized choice of component configuration based on scapulothoracic orientation seems to attenuate the negative effects of posture Type B and C. Future studies on ROM after RTSA should consider patient posture and scapulothoracic orientation. CLINICAL RELEVANCE: In patients with Type C posture, higher retrotorsion, a lower neck-shaft angle, and a larger or inferior eccentric glenosphere seem to be advantageous.


Asunto(s)
Artroplastía de Reemplazo de Hombro/métodos , Posicionamiento del Paciente , Postura , Rango del Movimiento Articular , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Periodo Preoperatorio , Programas Informáticos , Tomografía Computarizada por Rayos X
8.
Arch Orthop Trauma Surg ; 141(2): 183-188, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32221702

RESUMEN

INTRODUCTION: Shorter humeral reverse total shoulder arthroplasty (RTSA) stems may reduce stress shielding, however, potentially carry the risk of varus/valgus malalignment. This radiographic study's purpose was to measure the incidence of stem malalignment and thus the realized neck-shaft angle (NSA). The hypothesis was that malalignment of the stem is a frequent postoperative radiographic finding. METHODS: Radiographs of an uncemented curved short stem RTSA with a 145° NSA were reviewed. The study group included 124 cases at a mean age of 74 (range 48-91) years. The humeral stem axis was measured and defined as neutral if the value fell within ± 5° of the longitudinal humeral axis. Angular values > 5° were defined as malaligned in valgus or varus. The filling ratio of the implant within the humeral shaft was measured at the level of the metaphysis (FRmet) and diaphysis (FRdia). RESULTS: The average humeral stem axis angle was 4 ± 3° valgus, corresponding to a true mean NSA of 149 ± 3°. Stem axis was neutral in 73% (n = 90) of implants. Of the 34 malaligned implants, 82% (n = 28) were in valgus (NSA = 153 ± 2°) and 18% (n = 6) in varus (NSA = 139 ± 1°). The average FRmet and FRdia were 0.68 ± 0.11 and 0.72 ± 0.11, respectively. A low positive association was found between stem diameter and filling ratios (r = 0.39; p < 0.001); indicating smaller stem sizes were more likely to be misaligned. CONCLUSION: Uncemented short stem implants may decrease stress shielding; however, approximately one quarter were implanted > 5° malaligned. The majority of malaligned components (86%) were implanted in valgus, corresponding to an NSA of > 150°. As such, surgeons must be aware that shorter and smaller stems may lead to axial malalignment influencing the true SA. LEVEL OF EVIDENCE: Level IV, retrospective study.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Húmero/cirugía , Prótesis Articulares , Adulto , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/instrumentación , Humanos , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos
9.
J Shoulder Elbow Surg ; 29(10): 2123-2127, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32340791

RESUMEN

INTRODUCTION: Preoperative 3D planning programs for anatomic (TSA) and reverse total shoulder arthroplasty (RSA) allow the analysis of glenohumeral joint pathoanatomy and templating for implant size selection and placement. The aim of this multicenter study was to compare the preoperative glenoid implant type and size planned to the final glenoid implant type and size used intraoperatively. METHODS: Two hundred patients (100 TSA and 100 RSA) with a mean age of 72 years who had undergone preoperative planning and subsequent shoulder arthroplasty (100 TSA and 100 RSA) were included. All preoperative plans were saved and were analyzed for arthroplasty type (TSA vs. RSA), implant type (augment vs. nonaugment), and size (ie, polyethylene size, polyethylene radius of curvature, glenoid baseplate diameter, baseplate post length, and baseplate lateralization). The preoperative plan was available during surgery and was compared to the final implants inserted by the surgeon. RESULTS: There were no intraoperative conversions of TSA to RSA or vice versa. In patients planned for a TSA, complete concordance between the preoperative plan and final implant selection was 85%. A complete mismatch for TSA glenoid size, backside radius of curvature, and augmentation occurred in 2%. For RSA, complete concordance was found in 90% of cases. A complete mismatch for implant type, size, post length, and glenosphere size occurred in 3%. CONCLUSION: A high concordance was found between preoperative 3D planning implant selection and the glenoid component inserted at surgery for TSA and RSA. This high concordance may assist with surgical preparedness, implant stocks, and possibly future implant production.


Asunto(s)
Artroplastía de Reemplazo de Hombro/instrumentación , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Prótesis de Hombro , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro/métodos , Toma de Decisiones Asistida por Computador , Femenino , Cavidad Glenoidea , Humanos , Imagenología Tridimensional , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Planificación de Atención al Paciente , Periodo Preoperatorio , Cirugía Asistida por Computador
10.
Arch Orthop Trauma Surg ; 140(11): 1587-1594, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31897591

RESUMEN

BACKGROUND: The degree of preoperative osteoarthritis has been shown to influence the postoperative outcome and the patients' satisfaction rate in hip and knee joint replacement surgery. However, no corresponding information is available for total shoulder arthroplasty (TSA). We therefore set out to evaluate the influence of preoperatively measured end-stage osteoarthritis on the postoperative clinical outcome of TSA. METHODS: A retrospective analysis of 103 anatomic total shoulder replacements (96 patients) was performed. Patients were evaluated radiologically with X-rays in two planes and clinically using the Constant and Murley score (CS) and the self-reported satisfaction with the result. The degree of osteoarthritis was radiographically analyzed with the aid of the classifications according to Kellgren/Lawrence, Gerber, Guyette, and Allain and according to whether complete narrowing of the glenohumeral joint was present or not [bone-on-bone contact (BOB) or no bone-on-bone contact (No BOB)]. RESULTS: The clinical results of TSA did not differ significantly among the various stages of osteoarthritis in any of the classifications (p > 0.05). The CS was significantly higher postoperatively for both the BOB and the No BOB group (p < 0.0001). Patients with BOB had a significantly lower CS preoperatively than patients with No BOB (p = 0.0172). In addition, the preoperative pain level was significantly higher in patients with BOB (p = 0.014). Postoperatively, no significant difference in CS (p = 0.6738) was found between the BOB group and the No BOB group. The mean improvement in CS was not statistically significant (p = 0.2218). CONCLUSION: In contrast to hip and knee joint replacement procedures, a milder grade of osteoarthritis does not adversely influence the functional result or subjective satisfaction rate after TSA. The degree of osteoarthritis on conventional X-rays has no bearing on the postoperative clinical outcome. Therefore, the decision on when to carry out anatomic total shoulder arthroplasty should depend on the patient's pain level and loss of quality of life.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteoartritis , Articulación del Hombro , Humanos , Osteoartritis/epidemiología , Osteoartritis/fisiopatología , Dolor Postoperatorio , Calidad de Vida , Estudios Retrospectivos , Articulación del Hombro/fisiopatología , Articulación del Hombro/cirugía , Resultado del Tratamiento
11.
BMC Musculoskelet Disord ; 20(1): 134, 2019 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-30922289

RESUMEN

BACKGROUND: Sufficient data on outcome of patients with clinically and radiologically aggressive enchondromas and atypical cartilaginous tumors (ACT) is lacking. We therefore analyzed both conservatively and surgically treated patients with lesions, which were not distinguishable between benign enchondroma and low-grade malignant ACT based upon clinical and radiologic appearance. METHODS: The series included 228 consecutive cases with a follow-up > 24 months to assess radiological, histological, and clinical outcome including recurrences and complications. Pain, satisfaction, functional limitations, and the musculoskeletal tumor society (MSTS) score were evaluated to judge both function and emotional acceptance at final follow-up. RESULTS: Follow-up took place at a mean of 82 (median 75) months. The 228 patients all had comparable clinical and radiological findings. Of these, 153 patients were treated conservatively, while the other 75 patients underwent intralesional curettage. Besides clinical and radiological aggressiveness, most lesions were histologically judged as benign enchondromas. 9 cases were determined to be ACT, while the remaining 7 cases had indeterminate histology. After surgery, three patients developed a recurrence, and a further seven had complications of which six were related to osteosynthesis. Both groups had excellent and almost equal MSTS scores of 96 and 97%, respectively, but significantly less functional limitations were found in the non-surgery group. Further sub-analyses were performed to reduce selection bias. Sub-analysis of histologically diagnosed enchondromas in the surgery group found more pain, less function, and worse MSTS score compared to the non-surgery group. Sub-analysis of smaller lesions (< 4.4 cm) did not show significant differences. In contrast, larger lesions displayed significantly worse results after surgery compared to conservative treatment (enchondromas > 4.4 cm: MSTS score: 94.0% versus 97.3%, p = 0.007; pain 2.3 versus 0.8, p = 0.001). The majority of lesions treated surgically was filled with polymethylmethacrylate bone-cement, while the remainder was filled with cancellous-bone, without significant difference in clinical outcome. CONCLUSION: Feasibility of intralesional curettage strategies for symptomatic benign to low-grade malignant chondrogenic tumors was supported. Surgery, however, did not prove superior compared to conservative clinical and radiological observation. Due to the low risk of transformation into higher-grade tumors and better functional results, more lesions might just be observed if continuous follow-up is assured.


Asunto(s)
Neoplasias Óseas/terapia , Condroma/terapia , Condrosarcoma/terapia , Tratamiento Conservador/métodos , Legrado/métodos , Huesos del Brazo/diagnóstico por imagen , Huesos del Brazo/patología , Huesos del Brazo/cirugía , Cementos para Huesos/uso terapéutico , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/epidemiología , Neoplasias Óseas/patología , Condroma/diagnóstico por imagen , Condroma/patología , Condrosarcoma/epidemiología , Condrosarcoma/patología , Toma de Decisiones Clínicas , Tratamiento Conservador/efectos adversos , Legrado/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Huesos de la Pierna/diagnóstico por imagen , Huesos de la Pierna/patología , Huesos de la Pierna/cirugía , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/epidemiología , Recurrencia Local de Neoplasia/prevención & control , Dimensión del Dolor , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/epidemiología , Dolor Postoperatorio/etiología , Satisfacción del Paciente , Selección de Paciente , Polimetil Metacrilato/uso terapéutico , Estudios Retrospectivos , Resultado del Tratamiento
12.
J Shoulder Elbow Surg ; 28(4): 715-723, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30473242

RESUMEN

BACKGROUND: Several short-stemmed press-fit humeral components have been developed in recent years for anatomic total shoulder arthroplasty (TSA) as well as reverse shoulder arthroplasty (RSA). Varying radiographic outcomes have been reported, with some studies reporting concerning rates of aseptic loosening. This study analyzed the radiographic findings of a press-fit convertible short-stemmed humeral component in both TSA and RSA. METHODS: There were 150 anatomic TSAs (group 1) and 77 RSAs (group 2) analyzed radiographically at a minimum follow-up of 2 years postoperatively. Plain radiographs were reviewed for stem loosening, alignment, signs of stress shielding, and the filling ratio. RESULTS: At final follow-up, 49% of group 1 and 65% of group 2 had no evidence for radiographic changes. In those with radiographic changes, low bone adaptions were found in 83% and high adaptions in 17% in both groups. Larger stem sizes with higher filling ratios were associated with high radiographic adaptions in both groups (P = .02). The overall filling ratios were higher in group 2 (P = .002). Cortical contact of the stem led to higher bone adaptions (P = .014). CONCLUSIONS: The short humeral component analyzed in this study showed encouraging survival rates without aseptic loosening. Radiographic changes are associated with a higher filling ratio and cortical contact of the stem. Surgeons should aim to achieve fixation with the minimal required canal filling to minimize radiographic changes with the uncemented humeral component used in this study.


Asunto(s)
Artroplastía de Reemplazo de Hombro/instrumentación , Articulación del Hombro/diagnóstico por imagen , Prótesis de Hombro , Adulto , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Diseño de Prótesis , Falla de Prótesis , Radiografía , Estudios Retrospectivos , Resultado del Tratamiento
13.
J Shoulder Elbow Surg ; 28(3): 539-546, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30518478

RESUMEN

BACKGROUND: Products from metal wear have been identified as a potential cause of adverse local tissue reactions and implant failure in total hip arthroplasty. However, the role of metal ion exposure in patients after total shoulder replacement is unclear. The objective of the present study was to determine in vivo blood metal ion levels of cobalt, chromium, and titanium in patients after anatomic total shoulder arthroplasty (TSA) or reverse TSA. METHODS: A consecutive series of patients after anatomic TSA or reverse TSA was evaluated retrospectively. After exclusion of patients with additional metal implants, 40 patients with unilateral anatomic TSA (n = 20) or reverse TSA (n = 20) were available for whole-blood metal ion analysis at a mean follow-up of 28 ± 9.6 months. Twenty-three healthy individuals without metal implants served as a control group. RESULTS: Mean cobalt ion concentrations were 0.18 µg/L (range, 0.1-0.66 µg/L), 0.15 µg/L (range, 0.03-0.48 µg/L), and 0.11 µg/L (range, 0.03-0.19 µg/L), mean chromium ion levels were 0.48 µg/L (range, 0.17-2.41 µg/L), 0.31 µg/L (range, 0.09-1.26 µg/L), and 0.14 µg/L (range, 0.04-0.99 µg/L), and mean titanium ion concentrations were 1.31 µg/L (range, 0.75-4.52 µg/L), 0.84 µg/L (range, 0.1-1.64 µg/L), and 0.62 µg/L (range, 0.32-2.14 µg/L) in the reverse TSA group, the anatomic TSA group, and the control group, respectively. CONCLUSIONS: TSA resulted in elevated metal ion levels compared with healthy controls, although overall metal ion concentrations measured in this study were relatively low. The role of local metal ion exposure in patients with total shoulder replacements should be further investigated.


Asunto(s)
Artroplastía de Reemplazo de Hombro/instrumentación , Cromo/sangre , Cobalto/sangre , Prótesis de Hombro , Titanio/sangre , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro/métodos , Estudios de Casos y Controles , Estudios Transversales , Femenino , Estudios de Seguimiento , Humanos , Iones/sangre , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Prótesis de Hombro/efectos adversos
14.
Arch Orthop Trauma Surg ; 139(2): 149-154, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30242565

RESUMEN

INTRODUCTION: The aim of the study was to evaluate the short-term clinical results of anatomic total shoulder arthroplasty with a short-stem prosthesis in primary osteoarthritis. MATERIALS AND METHODS: 65 shoulders with a mean age of 70 years (range 47-85 years) were available for minimum follow-up of 24 months. Clinical outcome was determined by range of motion, Constant score (CS) age and sex-adjusted Constant score (CS%), and subjective shoulder value (SSV). The influence of six different factors (high bone adaptations, age > 65 years, female gender, dominant side, atrophy of the supraspinatus tendon ≥ grade 2, glenoid type B2/B3) on the clinical outcome was assessed. RESULTS: At mean follow-up of 37 months (range 24-58 months), the CS improved from 36 ± 8 to 75 ± 12 (p < 0.001). The shoulder flexion (100° ± 21° to 159° ± 19°) as well as the external rotation (3° ± 11° to 43° ± 18°) improved significantly (p < 0.001). Three complications were noted (transient neuropraxia of the radial nerve, subjective instability, hematoma with superficial wound infection) leading to one revision surgery (wound debridement). No stem loosening was observed. High bone adaptation was present in 19 out of 65 shoulders (29%). The clinical outcome was not influenced by high bone adaptations (p ≥ 0.095). Age > 65 years (n = 44) and female gender (n = 38) were associated with worse clinical outcome (p ≤ 0.043). CONCLUSIONS: In the short term, the clinical results of this anatomical short-stem shoulder prosthesis are encouraging. A low prevalence of high bone adaptations was found without any influence on the clinical outcome and stem loosening was not observed.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteoartritis , Complicaciones Posoperatorias , Articulación del Hombro , Prótesis de Hombro , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico , Osteoartritis/cirugía , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Radiografía/métodos , Rango del Movimiento Articular , Reoperación/métodos , Estudios Retrospectivos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento
15.
World J Surg Oncol ; 16(1): 139, 2018 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-30005680

RESUMEN

BACKGROUND: Enchondromas and atypical cartilaginous tumors (ACT) are often located at the proximal humerus. Most lesions can be followed conservatively, but surgical resection may alleviate pain, avoid pathological fractures, and prevent transformation into higher grade chondrosarcomas. Rigorous intralesional resection and filling with polymethylmethacrylate bone cement has been proposed for enchondromas but also for ACT, as an alternative for extralesional resection. We intended to analyze radiological, clinical, and functional outcome of this strategy and compare bone cement without osteosynthesis to bone cement compound osteosynthesis, which has not been analyzed so far. METHODS: We retrospectively analyzed 42 consecutive patients (mean follow-up 73 months; range 8-224) after curettage and bone cement filling with or without osteosynthesis. Exclusion criteria were Ollier's disease and cancellous bone filling. Twenty-five patients only received bone cement. Seventeen patients received additional proximal humerus plate for compound osteosynthesis to increase stability after curettage. Demographics and radiological and clinical outcome were analyzed including surgery time, blood loss, hospitalization, recurrences, and complications. An additional telephone interview at the final follow-up assessed postoperative satisfaction, pain, and function in the quick disabilities of the arm, shoulder, and hand (DASH) score and the Musculoskeletal Tumor Society (MSTS) score. Statistics included the Student T tests, Mann-Whitney U tests, and chi-square tests. RESULTS: No osteosynthesis compared to compound osteosynthesis showed smaller tumors (4.2 (± 1.5) cm versus 6.6 (± 3.0) cm; p = 0.005) and smaller bone cement fillings after curettage (5.7 (± 2.1) cm versus 9.6 (± 3.2) cm; p = 0.0001). A score evaluating preoperative scalloping and soft-tissue extension did not significantly differ (1.9 (± 0.9) versus 2.0 (± 1.0); rating scale 0-4; p = 0.7). Both groups showed high satisfaction (9.2 (± 1.5) versus 9.2 (± 0.9); p = 0.5) and low pain (1.0(±1.7) versus 1.9(±1.8); p = 0.1) in a rating scale from 0 to 10. Clinical and functional outcome was excellent for both groups in the DASH score (6.0 (± 11.8) versus 11.0 (± 13.2); rating scale 0-100; p = 0.2) and the MSTS score (29.0 (± 1.7) versus 28.7 (± 1.1); rating scale 0-30; p = 0.3). One enchondroma recurrence was found in the group without osteosynthesis. Complications (one fracture and one intra-articular screw) were only detected after osteosynthesis. Osteosynthesis had longer surgery time (70 (± 21) min versus 127 (± 22) min; p < 0.0001), more blood loss (220 (± 130) ml versus 460 (± 210) ml; p < 0.0001), and longer stay in the hospital (6 (± 2) days versus 8 (± 2) days; p = 0.004). CONCLUSIONS: Intralesional tumor resection was oncologically safe and clinically successful with or without osteosynthesis. Osteosynthesis did not reduce the risk for fracture but was more invasive.


Asunto(s)
Neoplasias Óseas/cirugía , Cartílago Articular/cirugía , Condroma/cirugía , Húmero/cirugía , Adulto , Cementos para Huesos , Cartílago Articular/patología , Cementación , Legrado , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Hombro/patología , Hombro/cirugía , Resultado del Tratamiento
16.
J Shoulder Elbow Surg ; 27(6): 1139-1147, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29422391

RESUMEN

Uncemented press-fit humeral stems were developed with the goal of decreasing operative time, preserving bone stock, and easing revision. In recent years, short stems and stemless humeral implants have also become available. These press-fit humeral implants have varying designs that can lead to changes in stress distribution in the proximal humerus. Such stress shielding manifests as bony adaptations and may affect long-term functional outcome and the ability to perform revision. However, current studies of humeral fixation during total shoulder arthroplasty are complicated because a variety of classification systems have been used to report findings. The purpose of this report is to review the current literature on press-fit fixation of the humeral component during total shoulder arthroplasty and propose minimum requirements for radiographic descriptions of stress shielding.


Asunto(s)
Artroplastía de Reemplazo de Hombro/instrumentación , Húmero/cirugía , Diseño de Prótesis , Prótesis de Hombro , Humanos , Ajuste de Prótesis , Rango del Movimiento Articular , Soporte de Peso
17.
J Shoulder Elbow Surg ; 27(5): 839-845, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29292036

RESUMEN

BACKGROUND: This study analyzed the radiographic results of a cemented all-polyethylene keeled glenoid component available in different sizes and multiple backside radiuses of curvature. METHODS: The study group consisted of 118 cases (114 patients). There were 63 women and 51 men. Mean age at the time of arthroplasty was 68 years (range, 51-85 years). True anterior-posterior radiographs obtained postoperatively and at the final follow-up were analyzed for implant seating and the occurrence of radiolucent lines. Glenoid morphology and fatty infiltration of the rotator cuff muscles were examined using computed tomography scans. Mean follow-up was 38 months (range, 24-70 months). RESULTS: The mean radiolucent line score after surgery was 0.54 points (range, 0-3 points), and 90% had no or only 1 radiolucent line. At the final follow-up, the mean score was 1.06 points (range, 0-3 points), and 74% had no or only 1 radiolucent line. The score increased significantly over time (P < .001). No component was at risk for loosening. No correlation was found between patient age, sex, hand dominance, glenoid morphology, or fatty infiltration of the rotator cuff muscles and the occurrence of radiolucent lines. CONCLUSION: In the short-term, the glenoid component analyzed in this study showed promising radiographic results, with a low number of radiolucent lines without failure. However, the mean radiolucent line score increased significantly over time, and long-term observations are necessary to confirm a possible advantage compared with older component designs.


Asunto(s)
Artroplastía de Reemplazo de Hombro/métodos , Osteoartritis/cirugía , Polietileno , Articulación del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico , Diseño de Prótesis , Articulación del Hombro/diagnóstico por imagen , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
18.
J Shoulder Elbow Surg ; 27(6): 1004-1011, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29428293

RESUMEN

BACKGROUND: We investigated the impact of poor seated posture on the prevalence of rotator cuff tears (RCTs) among wheelchair-dependent individuals with long-standing paraplegia. METHODS: The study included 319 patients. Lateral radiographs of the spine were collected from a database and analyzed to assess the global spinopelvic alignment (SPA). Magnetic resonance images of both shoulders were obtained to detect the presence of cuff tears. Patients were divided into 2 groups: Group RCT-I included all patients with cuff tears (right, left, or bilateral), whereas group RCT-II consisted exclusively of patients with bilateral cuff tears. We used the classification systems developed by Kendall et al and Roussouly et al to assess the sagittal spine alignment and SPA, respectively. Univariate and multivariate analyses were performed. To fit both models (groups RCT-I and RCT-II) to the data, the 4 spine curves according to Roussouly et al were subdivided into 2 groups: Group SPA-I included both type 1 and type 2, whereas group SPA-II included both type 3 and type 4. RESULTS: Magnetic resonance images showed a cuff tear in 192 patients (60.19%) (group RCT-I). Among those, 37 patients (11.60%) had tears in both shoulders (group RCT-II). In group RCT-I, 70.31% of the patients had a kyphotic-lordotic posture. The kyphotic-lordotic posture, a longer duration, and a more rostral neurologic level of injury were highly associated with cuff tear prevalence. In group RCT-II, the multivariate analysis showed that only the duration of spinal cord injury was significantly associated with RCTs. CONCLUSION: Thoracic hyperkyphosis was associated with a markedly high rate of RCTs. The data from this study may provide support for developing preventive strategies.


Asunto(s)
Paraplejía/rehabilitación , Postura , Lesiones del Manguito de los Rotadores/epidemiología , Traumatismos de la Médula Espinal/complicaciones , Silla de Ruedas , Adulto , Anciano , Estudios Transversales , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Análisis Multivariante , Paraplejía/diagnóstico por imagen , Paraplejía/etiología , Prevalencia , Estudios Retrospectivos , Factores de Tiempo
19.
Arch Orthop Trauma Surg ; 138(11): 1487-1494, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29974217

RESUMEN

BACKGROUND: Clinical studies suggest that reaming of the subchondral bone layer to achieve good implant seating is a risk factor for glenoid loosening. This study aims to evaluate (1) the importance of the subchondral bone layer and (2) the influence of the design of the glenoid component. METHODS: Different techniques for preparation of an A1 glenoid were compared: (1) preserving the subchondral bone layer; (2) removal of the subchondral bone layer; (3) implantation of a glenoid component that does not adapt to the native anatomy. Artificial glenoid bones (n = 5 each) were used with a highly standardized preparation and implantation protocol. Biomechanical testing was performed during simulated physiological shoulder motion. Using a high-resolution optical system, the micromotions between implant and bone were measured up to 10,000 motion cycles. RESULTS: At the 10,000 cycle measuring point, significantly more micromotions were found in the subchondral layer removed group than in the subchondral layer preserved group (p = 0.0427). The number of micromotions in the nonadapted group was significantly higher than in the subchondral layer preserved group (p = 0.0003) or the subchondral layer removed group (p = 0.0207). CONCLUSION: Conservative reaming proved important to diminish the micromotions of the glenoid component. Implantation of a glenoid component that matches with the bony underlying glenoid can help to preserve the subchondral bone layer without sacrificing proper implant seating.


Asunto(s)
Artroplastía de Reemplazo de Hombro/instrumentación , Diseño de Prótesis/métodos , Articulación del Hombro/cirugía , Prótesis de Hombro , Artroplastía de Reemplazo de Hombro/métodos , Fenómenos Biomecánicos , Cavidad Glenoidea/cirugía , Humanos , Modelos Anatómicos
20.
Arch Orthop Trauma Surg ; 138(7): 891-899, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29516162

RESUMEN

BACKGROUND: Glenoid replacement in cases of severe glenoid retroversion (RV) or eccentric wear is challenging. The aim of this study was to evaluate different treatment methods under standardized conditions to assist surgeons in the decision-making process. METHODS: Three treatment options for severe glenoid RV (15°) were compared: (1) no RV correction; (2) complete RV correction; (3) no RV correction and implantation of a posterior augmented glenoid (PAG). A highly standardized implantation protocol using artificial glenoid bones (five per group) was chosen, and a physiologic shoulder movement was applied in a biomechanical setting. Micromotions (MM) between glenoid components and bone were quantified using an optical 3D measuring system. RESULTS: In the uncorrected retroversion group, three instances of subluxation of the prosthetic head occurred between 2000 and 4000 cycles. At 2000 cycles, significantly more MM were observed in the uncorrected RV group than in the corrected RV group (p < 0.0001) or to the augmented group (p < 0.0001). At 10|000 cycles, more MM were observed in the posterior augmented group than in the corrected RV group (p < 0.0001). CONCLUSION: If sufficient bone stock is available, retroversion correction should be favored. Posterior augmented glenoids seem to be a suitable treatment option if complete correction of the retroversion is not possible without compromising the glenoid vault. Without correction of the retroversion, high failure rates were observed.


Asunto(s)
Artroplastía de Reemplazo de Hombro/métodos , Cavidad Glenoidea/cirugía , Osteoartritis/cirugía , Articulación del Hombro/cirugía , Artroplastía de Reemplazo de Hombro/efectos adversos , Fenómenos Biomecánicos , Humanos , Luxaciones Articulares/etiología , Osteoartritis/fisiopatología , Complicaciones Posoperatorias , Articulación del Hombro/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA