Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Opt Lett ; 49(6): 1563-1566, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38489451

RESUMEN

One major drawback of the classic time-correlated single photon counting (TCSPC) technique is pileup-related distortion. To keep it under a reasonable level, the maximum count rate has to be reduced, posing a serious limitation to the overall measurement speed. This means that there is an intrinsic trade-off between speed and distortion: either count rate is raised, but distortion is worsened, or distortion is minimized at the expense of speed. In both cases, it is impossible to precisely evaluate the degree of distortion introduced. Here comes our new, to the best of our knowledge, figure of merit, which is able to provide a numerical estimate of the distortion whatever the signal shape is, marking a real turning point in the way of doing TCSPC. In this article, this new parameter will be defined and its effectiveness will be demonstrated by means of mathematical computations.

2.
Opt Express ; 31(21): 33963-33999, 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37859164

RESUMEN

Picosecond timing of single photons has laid the foundation of a great variety of applications, from life sciences to quantum communication, thanks to the combination of ultimate sensitivity with a bandwidth that cannot be reached by analog recording techniques. Nowadays, more and more applications could still be enabled or advanced by progress in the available instrumentation, resulting in a steadily increasing research interest in this field. In this scenario, single-photon avalanche diodes (SPADs) have gained a key position, thanks to the remarkable precision they are able to provide, along with other key advantages like ruggedness, compactness, large signal amplitude, and room temperature operation, which neatly distinguish them from other solutions like superconducting nanowire single-photon detectors and silicon photomultipliers. With this work, we aim at filling a gap in the literature by providing a thorough discussion of the main design rules and tradeoffs for silicon SPADs and the electronics employed along them to achieve high timing precision. In the end, we conclude with our outlook on the future by summarizing new routes that could benefit from present and prospective timing features of silicon SPADs.

3.
Opt Lett ; 47(1): 82-85, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34951886

RESUMEN

One of the major drawbacks of time-correlated single-photon counting (TCSPC) is generally represented by pile-up distortion, which strongly bounds the maximum acquisition speed to a few percent of the laser excitation rate. Based on a previous theoretical analysis, recently we presented the first, to the best of our knowledge, low-distortion and high-speed TCSPC system capable of overcoming the pile-up limitation by perfectly matching the single-photon avalanche diode (SPAD) dead time to the laser period. In this work, we validate the proposed system in a standard fluorescence measurement by comparing experimental data with the reference theoretical framework. As a result, a count rate of 32 Mc/s was achieved with a single-channel system still observing a negligible lifetime distortion.

4.
Opt Express ; 29(3): 4559-4581, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33771031

RESUMEN

Single-photon detection is an invaluable tool for many applications ranging from basic research to consumer electronics. In this respect, the Single Photon Avalanche Diode (SPAD) plays a key role in enabling a broad diffusion of these techniques thanks to its remarkable performance, room-temperature operation, and scalability. In this paper we present a silicon technology that allows the fabrication of SPAD-arrays with an unprecedented combination of low timing jitter (95 ps FWHM) and high detection efficiency at red and near infrared wavelengths (peak of 70% at 650 nm, 45% at 800 nm). We discuss the device structure, the fabrication process, and we present a thorough experimental characterization of the fabricated detectors. We think that these results can pave the way to new exciting developments in many fields, ranging from quantum optics to single molecule spectroscopy.

5.
Opt Lett ; 46(6): 1353-1356, 2021 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-33720185

RESUMEN

Multispectral/hyperspectral fluorescence lifetime imaging microscopy (λFLIM) is a promising tool for studying functional and structural biological processes. The rich information content provided by a multidimensional dataset is often in contrast with the acquisition speed. In this work, we develop and experimentally demonstrate a wide-field λFLIM setup, based on a novel time-resolved 18×1 single-photon avalanche diode array detector working in a single-pixel camera scheme, which parallelizes the spectral detection, reducing measurement time. The proposed system, which implements a single-pixel camera with a compressive sensing scheme, represents an optimal microscopy framework towards the design of λFLIM setups.

6.
Sensors (Basel) ; 21(14)2021 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-34300590

RESUMEN

We present an optical depth imaging system suitable for highly scattering underwater environments. The system used the time-correlated single-photon counting (TCSPC) technique and the time-of-flight approach to obtain depth profiles. The single-photon detection was provided by a linear array of single-photon avalanche diode (SPAD) detectors fabricated in a customized silicon fabrication technology for optimized efficiency, dark count rate, and jitter performance. The bi-static transceiver comprised a pulsed laser diode source with central wavelength 670 nm, a linear array of 16 × 1 Si-SPAD detectors, with a dedicated TCSPC acquisition module. Cylindrical lenses were used to collect the light scattered by the target and image it onto the sensor. These laboratory-based experiments demonstrated single-photon depth imaging at a range of 1.65 m in highly scattering conditions, equivalent up to 8.3 attenuation lengths between the system and the target, using average optical powers of up to 15 mW. The depth and spatial resolution of this sensor were investigated in different scattering conditions.

7.
Opt Express ; 26(12): 15398-15410, 2018 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-30114802

RESUMEN

Time-Correlated Single Photon Counting (TCSPC) is an essential tool in many scientific applications, where the recording of optical pulses with picosecond precision is required. Unfortunately, a key issue has to be faced: distortion phenomena can affect TCSPC experiments at high count rates. In order to avoid this problem, TCSPC experiments have been commonly carried out by limiting the maximum operating frequency of a measurement channel below 5% of the excitation frequency, leading to a long acquisition time. Recently, it has been demonstrated that matching the detector dead time to the excitation period allows to keep distortion around zero regardless of the rate of impinging photons. This solution paves the way to unprecedented measurement speed in TCSPC experiments. In this scenario, the front-end circuits that drive the detector play a crucial role in determining the performance of the system, both in terms of measurement speed and timing performance. Here we present two fully integrated front-end circuits for Single Photon Avalanche Diodes (SPADs): a fast Active Quenching Circuit (AQC) and a fully-differential current pick-up circuit. The AQC can apply very fast voltage variations, as short as 1.6ns, to reset external custom-technology SPAD detectors. A fast reset, indeed, is a key parameter to maximize the measurement speed. The current pick-up circuit is based on a fully differential structure which allows unprecedented rejection of disturbances that typically affect SPAD-based systems at the end of the dead time. The circuit permits to sense the current edge resulting from a photon detection with picosecond accuracy and precision even a few picoseconds after the end of the dead time imposed by the AQC. This is a crucial requirement when the system is operated at high rates. Both circuits have been deeply characterized, especially in terms of achievable measurement speed and timing performance.

8.
IEEE Photonics Technol Lett ; 30(6): 557-560, 2018 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-29581700

RESUMEN

In this letter, the development and the experimental characterization of a new photon detection module, based on a 32×1 red-enhanced single-photon avalanche diode (RE-SPAD) array, are presented. A custom-developed technology has been exploited to design a detector having large-area pixels (50-µm diameter) with optimized performance. With an excess bias voltage Voυ = 15 V, a photon detection efficiency as high as 57% at 600 nm (33% at 800 nm) is achieved, along with dark count rate in the kHz range and optical crosstalk probability as low as 0.29%. The remarkable detection efficiency of the RE-SPAD array makes the module particularly suitable for all applications where high detection efficiency in the red/near-infrared range is mandatory. As an example, the performance of the array module is demonstrated to match the demanding requirements of multispot single-molecule fluorescence spectroscopy.

9.
J Chem Phys ; 148(12): 123304, 2018 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-29604810

RESUMEN

Single-molecule Förster resonance energy transfer (smFRET) allows measuring distances between donor and acceptor fluorophores on the 3-10 nm range. Solution-based smFRET allows measurement of binding-unbinding events or conformational changes of dye-labeled biomolecules without ensemble averaging and free from surface perturbations. When employing dual (or multi) laser excitation, smFRET allows resolving the number of fluorescent labels on each molecule, greatly enhancing the ability to study heterogeneous samples. A major drawback to solution-based smFRET is the low throughput, which renders repetitive measurements expensive and hinders the ability to study kinetic phenomena in real-time. Here we demonstrate a high-throughput smFRET system that multiplexes acquisition by using 48 excitation spots and two 48-pixel single-photon avalanche diode array detectors. The system employs two excitation lasers allowing separation of species with one or two active fluorophores. The performance of the system is demonstrated on a set of doubly labeled double-stranded DNA oligonucleotides with different distances between donor and acceptor dyes along the DNA duplex. We show that the acquisition time for accurate subpopulation identification is reduced from several minutes to seconds, opening the way to high-throughput screening applications and real-time kinetics studies of enzymatic reactions such as DNA transcription by bacterial RNA polymerase.


Asunto(s)
ADN/química , Transferencia Resonante de Energía de Fluorescencia/métodos , Colorantes Fluorescentes/química , Cinética , Factores de Tiempo
10.
Opt Express ; 24(16): 17819-31, 2016 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-27505749

RESUMEN

Single photon avalanche diodes (SPADs) have been subject to a fast improvement in recent years. In particular, custom technologies specifically developed to fabricate SPAD devices give the designer the freedom to pursue the best detector performance required by applications. A significant breakthrough in this field is represented by the recent introduction of a red enhanced SPAD (RE-SPAD) technology, capable of attaining a good photon detection efficiency in the near infrared range (e.g. 40% at a wavelength of 800 nm) while maintaining a remarkable timing resolution of about 100ps full width at half maximum. Being planar, the RE-SPAD custom technology opened the way to the development of SPAD arrays particularly suited for demanding applications in the field of life sciences. However, to achieve such excellent performance custom SPAD detectors must be operated with an external active quenching circuit (AQC) designed on purpose. Next steps toward the development of compact and practical multichannel systems will require a new generation of monolithically integrated AQC arrays. In this paper we present a new, fully integrated AQC fabricated in a high-voltage 0.18 µm CMOS technology able to provide quenching pulses up to 50 Volts with fast leading and trailing edges. Although specifically designed for optimal operation of RE-SPAD devices, the new AQC is quite versatile: it can be used with any SPAD detector, regardless its fabrication technology, reaching remarkable count rates up to 80 Mcounts/s and generating a photon detection pulse with a timing jitter as low as 119 ps full width at half maximum. The compact design of our circuit has been specifically laid out to make this IC a suitable building block for monolithically integrated AQC arrays.

11.
IEEE Photonics Technol Lett ; 28(9): 1002-1005, 2016 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-27175050

RESUMEN

In this letter we present a compact photon detection module, based on an 8×8 array of single-photon avalanche diodes (SPADs). The use of a dedicated silicon technology for the fabrication of the sensors allows us to combine large active areas (50-µm diameter), high photon detection efficiency (49% at 550-nm wavelength) and low dark count rate. Thanks to a fully parallel architecture, the module provides voltage pulses synchronous to each photon detection for a maximum global count rate exceeding 1 Gcps. These properties makes the system suitable for operation in two different free-running modes. The first, suitable to acquire faint signals, allows multi-spot acquisitions and can be used to considerably reduce the measurement time in applications like single-molecule analysis. With the second it is possible to use all the pixels in a combined mode, to extend and move the dynamic range of the module to very high count rates and to attain number resolving capabilities.

12.
IEEE J Sel Top Quantum Electron ; 20(6): 38044201-380442020, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25309114

RESUMEN

Solution-based single-molecule fluorescence spectroscopy is a powerful experimental tool with applications in cell biology, biochemistry and biophysics. The basic feature of this technique is to excite and collect light from a very small volume and work in a low concentration regime resulting in rare burst-like events corresponding to the transit of a single molecule. Detecting photon bursts is a challenging task: the small number of emitted photons in each burst calls for high detector sensitivity. Bursts are very brief, requiring detectors with fast response time and capable of sustaining high count rates. Finally, many bursts need to be accumulated to achieve proper statistical accuracy, resulting in long measurement time unless parallelization strategies are implemented to speed up data acquisition. In this paper we will show that silicon single-photon avalanche diodes (SPADs) best meet the needs of single-molecule detection. We will review the key SPAD parameters and highlight the issues to be addressed in their design, fabrication and operation. After surveying the state-of-the-art SPAD technologies, we will describe our recent progress towards increasing the throughput of single-molecule fluorescence spectroscopy in solution using parallel arrays of SPADs. The potential of this approach is illustrated with single-molecule Förster resonance energy transfer measurements.

13.
Phys Rev Lett ; 109(14): 147405, 2012 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-23083286

RESUMEN

We show that quantum frequency conversion (QFC) can overcome the spectral distinguishability common to inhomogeneously broadened solid-state quantum emitters. QFC is implemented by combining single photons from an InAs/GaAs quantum dot (QD) at 980 nm with a 1550 nm pump laser in a periodically poled lithium niobate (PPLN) waveguide to generate photons at 600 nm with a signal-to-background ratio exceeding 100:1. Photon correlation and two-photon interference measurements confirm that both the single photon character and wave packet interference of individual QD states are preserved during frequency conversion. Finally, we convert two spectrally separate QD transitions to the same wavelength in a single PPLN waveguide and show that the resulting field exhibits nonclassical two-photon interference.

14.
Rev Sci Instrum ; 93(4): 043103, 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35489934

RESUMEN

At the present time, Single Photon Avalanche Diodes (SPADs) are the enabling devices in many applications, ranging from medical imaging to laser ranging and from remote sensing to quantum key distribution. Even though they belong to different scientific domains, these applications share the need for a detector capable of attaining high count rates possibly without trading it off with other key detector's features, such as afterpulsing probability, photon detection efficiency, and dark counts. In this work, we present the characterization of a fast integrated active quenching circuit capable of driving high-performance external custom-technology SPADs for single photon detection in the visible wavelength range. Combining the prompt intervention of the electronic circuitry and the performance of a custom-technology SPAD, we attained count rates up to 250 MCps while keeping the afterpulsing probability within 2%.


Asunto(s)
Conducción de Automóvil , Semiconductores , Luz , Fotones , Probabilidad
15.
Opt Express ; 16(12): 8381-94, 2008 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-18545552

RESUMEN

One of the main issues of Single Photon Avalanche Diode arrays is optical crosstalk. Since its intensity increases with reducing the distance between devices, this phenomenon limits the density of integration within arrays. In the past optical crosstalk was ascribed essentially to the light propagating from one detector to another through direct optical paths. Accordingly, reflecting trenches between devices were proposed to prevent it, but they proved to be not completely effective. In this paper we will present experimental evidence that a significant contribution to optical crosstalk comes from light reflected internally off the bottom of the chip, thus being impossible to eliminate it completely by means of trenches. We will also propose an optical model to predict the dependence of crosstalk on the distance between devices.


Asunto(s)
Artefactos , Modelos Teóricos , Óptica y Fotónica/instrumentación , Fotometría/instrumentación , Semiconductores , Transductores , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Fotones , Dispersión de Radiación
16.
Electrophoresis ; 29(24): 4972-5, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19130576

RESUMEN

A novel microchip electrophoresis instrument based on single-photon avalanche diodes was used for the molecular characterization of mutations in disease genes. The identification of the main mutation causing cystic fibrosis, named DeltaF508, by the Amplification Refractory Mutation System was used to validate the technology. In our implemented protocol the wild-type and mutant allele-specific primers are labeled with Cy5 and Cy5.5, respectively. The protocol enables the amplification of the DNA sample in a single PCR. The genotype was deduced from the fluorescence of the amplicons run in the CE microchip. Validation on 15 DNA samples from either homozygous wild-type or heterozygous and homozygous mutated control subjects proved the complete reliability of the system, thus confirming its high diagnostic potential.


Asunto(s)
Análisis Mutacional de ADN/métodos , Electroforesis por Microchip/instrumentación , Mutación/genética , Fotones , ADN/análisis , ADN/genética , Electroforesis por Microchip/métodos
17.
Nucl Instrum Methods Phys Res A ; 9(12): 255-258, 2018 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-31223178

RESUMEN

Single-molecule fluorescence spectroscopy (SMFS), based on the detection of individual molecules freely diffusing through the excitation spot of a confocal microscope, has allowed unprecedented insights into biological processes at the molecular level, but suffers from limited throughput. We have recently introduced a multispot version of SMFS, which allows achieving high-throughput SMFS by virtue of parallelization, and relies on custom silicon single-photon avalanche diode (SPAD) detector arrays. Here, we examine the premise of this parallelization approach, which is that data acquired from different spots is uncorrelated. In particular, we measure the optical crosstalk characteristics of the two 48-pixel SPAD arrays used in our recent SMFS studies, and demonstrate that it is negligible (crosstalk probability ≤ 1.1 10-3) and undetectable in cross-correlation analysis of actual single-molecule fluorescence data.

18.
Rev Sci Instrum ; 78(6): 063105, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17614603

RESUMEN

This article reports a complete characterization of single photon avalanche diodes (SPADs) at temperatures down to 120 K. We show that deep cooling of the device by means of a compact liquid-nitrogen Dewar brings several advantages, such as extremely low dark counting rates (down to 1 counts/s), better time resolution, and higher quantum efficiency in the visible range. By using a special current pick-off circuit, we achieved a time resolution of 20 ps full width at half maximum at 120 K for a 50 mum diameter SPAD. Afterpulsing effects are avoided by using a sufficiently long hold-off time (microseconds).


Asunto(s)
Congelación , Fotones , Radiometría/instrumentación , Semiconductores , Procesamiento de Señales Asistido por Computador/instrumentación , Silicio/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Proc SPIE Int Soc Opt Eng ; 102292017 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-28781415

RESUMEN

In recent years the development of Single-Photon Avalanche Diodes (SPADs) had a big impact on single-photon counting applications requiring high-performance detectors in terms of Dark Count Rate (DCR), Photon Detection Efficiency (PDE), afterpulsing probability, etc. Among these, it is possible to find applications in single-molecule fluorescence spectroscopy that suffer from long-time measurements. In these cases SPAD arrays can be a solution in order to shorten the measurement time, thanks to the high grade of parallelism they can provide. Moreover, applications in other fields (e.g. astronomy) demand for large-area single-photon detectors, able also to handle very high count rates. For these reasons we developed a new single-photon detection module, featuring an 8 × 8 SPAD array. Thanks to a dedicated silicon technology, the performance of the detector have been finely optimized, reaching a 49% detection efficiency at 550 nm, as well as low dark counts (2 kcount/s maximum all over the array). This module can be used in two different modes: the first is a multi-spot configuration, allowing the acquisition of 64 optical signals at the same time and considerably reducing the time needed for a measurement. The second operation mode instead exploits all the pixels in a combined mode, allowing the detection of a 64-times higher maximum photon rate (up to 2 Gcount/s). In addition, this configuration provides also an extended dynamic range and allows to attain photon number resolving capabilities. Dark counts, detection efficiency, linearity, afterpulsing and crosstalk probability have been characterized at different operating conditions.

20.
PLoS One ; 12(4): e0175766, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28419142

RESUMEN

We describe an 8-spot confocal setup for high-throughput smFRET assays and illustrate its performance with two characteristic experiments. First, measurements on a series of freely diffusing doubly-labeled dsDNA samples allow us to demonstrate that data acquired in multiple spots in parallel can be properly corrected and result in measured sample characteristics consistent with those obtained with a standard single-spot setup. We then take advantage of the higher throughput provided by parallel acquisition to address an outstanding question about the kinetics of the initial steps of bacterial RNA transcription. Our real-time kinetic analysis of promoter escape by bacterial RNA polymerase confirms results obtained by a more indirect route, shedding additional light on the initial steps of transcription. Finally, we discuss the advantages of our multispot setup, while pointing potential limitations of the current single laser excitation design, as well as analysis challenges and their solutions.


Asunto(s)
ADN/análisis , Microscopía/instrumentación , Espectrometría de Fluorescencia/instrumentación , ARN Polimerasas Dirigidas por ADN/metabolismo , Difusión , Diseño de Equipo , Escherichia coli/enzimología , Escherichia coli/genética , Ensayos Analíticos de Alto Rendimiento/instrumentación , Cinética , Rayos Láser , Microscopía Confocal/instrumentación , Regiones Promotoras Genéticas , Transcripción Genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA