RESUMEN
Objectives@#This study aimed to develop an accurate pediatric bone age prediction model by utilizing deep learning models and contrast conversion techniques, in order to improve growth assessment and clinical decision-making in clinical practice. @*Methods@#The study employed a variety of deep learning models and contrast conversion techniques to predict bone age. The training dataset consisted of pediatric left-hand X-ray images, each annotated with bone age and sex information. Deep learning models, including a convolutional neural network , Residual Network 50 , Visual Geometry Group 19, Inception V3, and Xception were trained and assessed using the mean absolute error (MAE). For the test data, contrast conversion techniques including fuzzy contrast enhancement, contrast limited adaptive histogram equalization (HE) , and HE were implemented. The quality of the images was evaluated using peak signal-to-noise ratio (SNR), mean squared error, SNR, coefficient of variation, and contrast-to-noise ratio metrics. The bone age prediction results using the test data were evaluated based on the MAE and root mean square error, and the t-test was performed. @*Results@#The Xception model showed the best performance (MAE=41.12). HE exhibited superior image quality, with higher SNR and coefficient of variation values than other methods. Additionally, HE demonstrated the highest contrast among the techniques assessed, with a contrast-to-noise ratio value of 1.29. Improvements in bone age prediction resulted in a decline in MAE from 2.11 to 0.24, along with a decrease in root mean square error from 0.21 to 0.02. @*Conclusion@#This study demonstrates that preprocessing the data before model training does not significantly affect the performance of bone age prediction when comparing contrast-converted images with original images.
RESUMEN
PURPOSE: The purpose of this study is to evaluate the treatment outcomes of adjuvant radiotherapy using vaginal brachytherapy (VB) with a lower dose per fraction and/or external beam radiotherapy (EBRT) following surgery for patients with stage I endometrial carcinoma. MATERIALS AND METHODS: The subjects were 43 patients with the International Federation of Gynecology and Obstetrics (FIGO) stage I endometrial cancer who underwent adjuvant radiotherapy following surgery between March 2000 and April 2014. Of these, 25 received postoperative VB alone, while 18 received postoperative EBRT to the whole pelvis; 3 of these were treated with EBRT plus VB. The median EBRT dose was 50.0 Gy (45.0–50.4 Gy) and the VB dose was 24 Gy in 6 fractions. Tumor dose was prescribed at a depth of 5 mm from the cylinder surface and delivered twice per week. RESULTS: The median follow-up period for all patients was 57 months (range, 9 to 188 months). Five-year disease-free survival (DFS) and overall survival (OS) for all patients were 92.5% and 95.3%, respectively. Adjuvant radiotherapy was performed according to risk factors and stage IB, grade 3 and lymphovascular invasion were observed more frequently in the EBRT group. Five-year DFS for EBRT and VB alone were 88.1% and 96.0%, respectively (p = 0.42), and 5-year OS for EBRT and VB alone were 94.4% and 96%, respectively (p = 0.38). There was no locoregional recurrence in any patient. Two patients who received EBRT and 1 patient who received VB alone developed distant metastatic disease. Two patients who received EBRT had severe complications, one each of grade 3 gastrointestinal complication and pelvic bone insufficiency fracture. CONCLUSION: Adjuvant radiotherapy achieved high DFS and OS with acceptable toxicity in stage I endometrial cancer. VB (with a lower dose per fraction) may be a viable option for selected patients with early-stage endometrial cancer following surgery.
Asunto(s)
Femenino , Humanos , Braquiterapia , Supervivencia sin Enfermedad , Neoplasias Endometriales , Estudios de Seguimiento , Fracturas por Estrés , Ginecología , Obstetricia , Huesos Pélvicos , Pelvis , Radioterapia , Radioterapia Adyuvante , Radioterapia Conformacional , Recurrencia , Factores de RiesgoRESUMEN
PURPOSE: To analyze prognostic factors for locoregional recurrence (LRR), distant metastasis (DM), and overall survival (OS) in cervical cancer patients who underwent radical hysterectomy followed by postoperative radiotherapy (PORT) in a single institute. MATERIALS AND METHODS: Clinicopathologic data of 135 patients with clinical stage IA2 to IIA2 cervical cancer treated with PORT from 2001 to 2012 were reviewed, retrospectively. Postoperative parametrial resection margin (PRM) and vaginal resection margin (VRM) were investigated separately. The median treatment dosage of external beam radiotherapy (EBRT) to the whole pelvis was 50.4 Gy in 1.8 Gy/fraction. High-dose-rate vaginal brachytherapy after EBRT was given to patients with positive or close VRMs. Concurrent platinum-based chemoradiotherapy (CCRT) was administered to 73 patients with positive resection margin, lymph node (LN) metastasis, or direct extension of parametrium. Kaplan-Meier method and log-rank test were used for analyzing LRR, DM, and OS; Cox regression was applied to analyze prognostic factors. RESULTS: The 5-year disease-free survival was 79% and 5-year OS was 91%. In univariate analysis, positive or close PRM, LN metastasis, direct extension of parametrium, lymphovascular invasion, histology of adenocarcinoma, and chemotherapy were related with more DM and poor OS. In multivariate analysis, PRM and LN metastasis remained independent prognostic factors for OS. CONCLUSION: PORT after radical hysterectomy in uterine cervical cancer showed excellent OS in this study. Positive or close PRM after radical hysterectomy in uterine cervical cancer correlates with poor prognosis even with CCRT. Therefore, additional treatments to improve local control such as radiation boosting need to be considered.
Asunto(s)
Humanos , Adenocarcinoma , Braquiterapia , Quimioradioterapia , Supervivencia sin Enfermedad , Quimioterapia , Histerectomía , Ganglios Linfáticos , Análisis Multivariante , Metástasis de la Neoplasia , Pelvis , Pronóstico , Radioterapia , Recurrencia , Estudios Retrospectivos , Neoplasias del Cuello UterinoRESUMEN
PURPOSE: To analyze prognostic factors for locoregional recurrence (LRR), distant metastasis (DM), and overall survival (OS) in cervical cancer patients who underwent radical hysterectomy followed by postoperative radiotherapy (PORT) in a single institute. MATERIALS AND METHODS: Clinicopathologic data of 135 patients with clinical stage IA2 to IIA2 cervical cancer treated with PORT from 2001 to 2012 were reviewed, retrospectively. Postoperative parametrial resection margin (PRM) and vaginal resection margin (VRM) were investigated separately. The median treatment dosage of external beam radiotherapy (EBRT) to the whole pelvis was 50.4 Gy in 1.8 Gy/fraction. High-dose-rate vaginal brachytherapy after EBRT was given to patients with positive or close VRMs. Concurrent platinum-based chemoradiotherapy (CCRT) was administered to 73 patients with positive resection margin, lymph node (LN) metastasis, or direct extension of parametrium. Kaplan-Meier method and log-rank test were used for analyzing LRR, DM, and OS; Cox regression was applied to analyze prognostic factors. RESULTS: The 5-year disease-free survival was 79% and 5-year OS was 91%. In univariate analysis, positive or close PRM, LN metastasis, direct extension of parametrium, lymphovascular invasion, histology of adenocarcinoma, and chemotherapy were related with more DM and poor OS. In multivariate analysis, PRM and LN metastasis remained independent prognostic factors for OS. CONCLUSION: PORT after radical hysterectomy in uterine cervical cancer showed excellent OS in this study. Positive or close PRM after radical hysterectomy in uterine cervical cancer correlates with poor prognosis even with CCRT. Therefore, additional treatments to improve local control such as radiation boosting need to be considered.
Asunto(s)
Humanos , Adenocarcinoma , Braquiterapia , Quimioradioterapia , Supervivencia sin Enfermedad , Quimioterapia , Histerectomía , Ganglios Linfáticos , Análisis Multivariante , Metástasis de la Neoplasia , Pelvis , Pronóstico , Radioterapia , Recurrencia , Estudios Retrospectivos , Neoplasias del Cuello UterinoRESUMEN
PURPOSE: To observe long-term clinical outcomes for patients with early-stage breast cancer treated with forward intensity-modulated radiation therapy (IMRT), including local control and clinical toxicities. MATERIALS AND METHODS: We retrospectively analyzed a total of 214 patients with stage I-II breast cancer who were treated with breast conserving surgery followed by adjuvant breast radiation therapy between 2001 and 2008. All patients were treated using forward IMRT. The whole breast was irradiated to a dose of 50 to 50.4 Gy followed by an 8 to 12 Gy electron boost to the surgical bed. RESULTS: The median age was 46 years (range, 21 to 82 years) and the medial follow-up time was 7.3 years (range, 2.4 to 11.7 years). Stage T1 was 139 (65%) and T2 was 75 (35%), respectively. Ipsilateral breast recurrence was observed in 3 patients. The 5- and 10-year local control rates were 99.1% and 97.8%, respectively. The cosmetic outcome was evaluated according to the Harvard scale and 89.4% of patients were scored as excellent or good. CONCLUSION: The whole breast radiation therapy as an adjuvant treatment using a forward IMRT technique showed excellent long-term local control as well as favorable outcomes of toxicity and cosmesis.
Asunto(s)
Humanos , Neoplasias de la Mama , Mama , Estudios de Seguimiento , Mastectomía Segmentaria , Recurrencia , Estudios RetrospectivosRESUMEN
In this paper, Acousto-Optical tomography is modeled by a linear integral equation and an inverse problem involving a diffusion equation in n-spatial dimensions. We make two-step mathematical model. First, we solve a linear integral equation. Assuming the optical energy fluence rate has been recovered from the previous equation, the absorption coefficient micro is then reconstructed by solving an inverse problem. Numerical experiments are presented for the case n=2. The traditional gradient descent method is used for the numerical simulations. The result of the gradient descent method produces the blurring effect. To get rid of the blurring effect, we suggest the total variation regularization for the minimization problem.
Asunto(s)
Absorción , Difusión , Combinación de Medicamentos , Modelos Teóricos , Butóxido de Piperonilo , PiretrinasRESUMEN
We experienced rare combination of multiple irregular shaped aneurysms along the course of the feeding artery and arteriovenous malformation (AVM) in the posterior circulation. We could not explain which aneurysm was a cause of bleeding because all the aneurysms showed irregular in shape like pseudoaneurysms and location of the aneurysms was very close each other. We report two cases in which multiple irregular shaped aneurysms were related with AVMs and first episode of hemorrhage.
Asunto(s)
Aneurisma , Aneurisma Falso , Arterias , Malformaciones Arteriovenosas , HemorragiaRESUMEN
PURPOSE: Thoracic radiotherapy is a major treatment modality of stage III non-small cell lung cancer. The normal lung tissue is sensitive to radiation and radiation pneumonitis is the most important dose-limiting complication of thoracic radiation therapy. This study was performed to identify the clinical and dosimetric parameters related to the risk of radiation pneumonitis after definitive radiotherapy in stage III non-small cell cancer patients. MATERIALS AND METHODS: The medical records were reviewed for 49 patients who completed definitive radiation therapy for locally advanced non-small cell lung cancer from August 2000 to February 2010. Radiation therapy was delivered with the daily dose of 1.8 Gy to 2.0 Gy and the total radiation dose ranged from 50.0 Gy to 70.2 Gy (median, 61.2 Gy). Elective nodal irradiation was delivered at a dose of 45.0 Gy to 50.0 Gy. Seven patients (14.3%) were treated with radiation therapy alone and forty two patients (85.7%) were treated with chemotherapy either sequentially or concurrently. RESULTS: Twenty-five cases (51.0%) out of 49 cases experienced radiation pneumonitis. According to the radiation pneumonitis grade, 10 (20.4%) were grade 1, 9 (18.4%) were grade 2, 4 (8.2%) were grade 3, and 2 (4.1%) were grade 4. In the univariate analyses, no clinical factors including age, sex, performance status, smoking history, underlying lung disease, tumor location, total radiation dose and chemotherapy were associated with grade > or =2 radiation pneumonitis. In the subgroup analysis of the chemotherapy group, concurrent rather than sequential chemotherapy was significantly related to grade > or =2 radiation pneumonitis comparing sequential chemotherapy. In the univariate analysis with dosimetric factors, mean lung dose (MLD), V20, V30, V40, MLDipsi, V20ipsi, V30ipsi, and V40ipsi were associated with grade > or =2 radiation pneumonitis. In addition, multivariate analysis showed that MLD and V30 were independent predicting factors for grade > or =2 radiation pneumonitis. CONCLUSION: Concurrent chemotherapy, MLD and V30 were statistically significant predictors of grade > or =2 radiation pneumonitis in patients with stage III non-small cell lung cancer undergoing definitive radiotherapy. The cutoff values for MLD and V30 were 16 Gy and 18%, respectively.
Asunto(s)
Humanos , Carcinoma de Pulmón de Células no Pequeñas , Pulmón , Enfermedades Pulmonares , Registros Médicos , Análisis Multivariante , Neumonitis por Radiación , Humo , FumarRESUMEN
The analog image based system consisted of a simulator and medical linear accelerator (LINAC) for radiotherapy was upgraded to digital medical image based system by exchanging the X-ray film with Computed Radiography (CR). With minimum equipments shift and similar treatment process, it was possible that the new digital image system was adapted by the users in short time. The film cassette and the film developer device were substituted with a CR cassette and a CR Reader, where the ViewBox was replaced with a small size PC and a monitor. The viewer software suitable for radiotherapy was developed to maximize the benefit of digital image, and as the result the convenience and the effectiveness was improved. It has two windows to display two different images in the same time and equipped various search capability, contouring, window leveling, image resizing, translation, rotation and registration functions. In order to avoid any discontinuance of the treatment while the transition to digital image, the film and the CR was used together for 1 week, and then the film developer was removed. Since then the CR System has been operated stably for 2 months, and the various requests from users have been reflected to improve the system.
Asunto(s)
Compuestos Organotiofosforados , Aceleradores de Partículas , Oncología por Radiación , Película para Rayos XRESUMEN
The purpose of this study was to analyze the effect of single-fraction stereotactic radiosurgery (SRS) for the treatment of 15 cases of cerebral arteriovenous malformations (AVMs). Between 2002 and 2009, of the 25 patients who had SRS for the treatment of cerebral AVM, 15 patients (6 men, 9 women) taken a digital subtraction angiography (DSA) over 12 months after SRS were included. We retrospectively evaluated the size, location, hemorrhage of nidus, angiographic changes on follow-up on the MR angiography and DSA, and clinical complications during follow-up periods. At a median follow-up of 24 months (range 12-89), complete obliteration of nidus was observed in all patients (100%) while residual draining veins was observed in 3 patients (20%). There was no clinical complication during the follow-up period except seizure in 1 patient. The mean nidus volume was 4.7cc (0.5~11.7 cc, SD 3.7 cc). The locations of nidus were in cerebral hemisphere in 11 patients, cerebellum in 2 patients, basal ganglia in 1 patient, and pons in 1 patient respectively. 9 cases were hemorrhagic, and 6 cases were non-hemorrhagic AVMs. The SRS with LINAC is a safe and effective treatment for cerebral AVMs when the follow up period is over 4 years. However, it is recommended to continue to follow up until the draining vein on arterial phase of follow up DSA disappears completely.
Asunto(s)
Humanos , Masculino , Angiografía , Angiografía de Substracción Digital , Ganglios Basales , Encéfalo , Cerebelo , Cerebro , Estudios de Seguimiento , Hemorragia , Malformaciones Arteriovenosas Intracraneales , Puente , Radiocirugia , Estudios Retrospectivos , Convulsiones , VenasRESUMEN
We measured the dose distribution for spinal cord and tumor using Gafchromic film, applying 3D and 4D-Treatment Planning for lung tumor within the phantom. A measured dose distribution was compared with a calculated dose distribution generated from 3D radiation treatment planning and 4D radiation treatment planning system. The agreement of the dose distribution in tumor for 3D and 4D treatment planning was 90.6%, 97.64% using gamma index computed for a distance to agreement of 1 mm and a dose difference of 3%. However, a gamma agreement index of 3% dose difference tolerence of and 2 mm distance to agreement, the accordance of the dose distribution around cord for 3D and 4D radiation treatment planning was 57.13%, 90.4%. There are significant differences between a calculated dose and a measured dose for 3D radiation treatment planning, no significant differences for 4D treatment planning. The results provide the effectiveness of the 4D treatment planning as compared to 3D. We suggest that the 4-dimensional treatment planning should be considered in the case where such equipments as Cyberknife with the real time tracking system are used to treat the tumors in the moving organ.
Asunto(s)
Pulmón , Radiocirugia , Médula Espinal , AtletismoRESUMEN
The intensity-modulated radiation therapy (IMRT) planning strategies for nasopharyngeal cancer among Korean radiation oncology facilities were investigated. Five institutions with IMRT planning capacity using the same planning system were invited to participate in this study. The institutions were requested to produce the best plan possible for 2 cases that would deliver 70 Gy to the planning target volume of gross tumor (PTV1), 59.4 Gy to the PTV2, and 51.5 Gy to the PTV3 in which elective irradiation was required. The advised fractionation number was 33. The planning parameters, resultant dose distributions, and biological indices were compared. We found 2-3-fold variations in the volume of treatment targets. Similar degree of variation was found in the delineation of normal tissue. The physician-related factors in IMRT planning had more influence on the plan quality. The inhomogeneity index of PTV dose ranged from 4 to 49% in Case 1, and from 5 to 46% in Case 2. Variation in tumor control probabilities for the primary lesion and involved LNs was less marked. Normal tissue complication probabilities for parotid glands and skin showed marked variation. Results from this study suggest that greater efforts in providing training and continuing education in terms of IMRT planning parameters usually set by physician are necessary for the successful implementation of IMRT.
Asunto(s)
Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Neoplasias Nasofaríngeas/radioterapia , Glándula Parótida/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Efectividad Biológica Relativa , Piel/efectos de la radiación , Carga TumoralRESUMEN
One of the most important task in commissioning intensity modulated radiotherapy (IMRT) into a clinic is the characterization of dosimetry performance under small monitor unit delivery conditions. In this study, method of evaluating dose monitor linearity, beam flatness and symmetry, and MLC positioning accuracy using a diode array is investigated. Siemens Primus linear accelerator (LA) with 6 and 10 MV x-rays was used to deliver radiation and the characteristics were measured using a multi array diodes. Monitor unit stabilities were measured for both x-ray energies. The dose linearity errors for the 6 MV x-ray were 2.1, 3.4, 6.9, 8.6, and 15.4 % when 20 MU, 10 MU, 5 MU, 4 MU, and 2 MU was delivered, respectively. Greater errors were observed for 10 MV x-rays with a maximum of 22% when 2 MU was delivered. These errors were corrected by adjusting D1_C0 values and reduced to less than 2% in all cases. The beam flatness and symmetry were appropriate without any correction. The picket fence test performed using diode array and film measurement showed similar results. The use of diode array is a convenient method in characterizing beam stability, symmetry and flatness, and positioning accuracy of MLC for IMRT commissioning. In addition, adjustment of D1-C0 value must be performed when a Siemens LA is used for IMRT because factory value usually gives unacceptable beam stability error when the MU/segment is smaller than 20.
Asunto(s)
Compuestos Organotiofosforados , Aceleradores de PartículasRESUMEN
PURPOSE: Three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) were found to reduce the incidence of acute and late rectal toxicity compared with conventional radiation therapy (RT), although acute and late urinary toxicities were not reduced significantly. Acute urinary toxicity, even at a low-grade, not only has an impact on a patient's quality of life, but also can be used as a predictor for chronic urinary toxicity. With bladder filling, part of the bladder moves away from the radiation field, resulting in a small irradiated bladder volume; hence, urinary toxicity can be decreased. The purpose of this study is to evaluate the impact of bladder volume on acute urinary toxicity during RT in patients with prostate cancer. MATERIALS AND METHODS: Forty two patients diagnosed with prostate cancer were treated by 3DCRT and of these, 21 patients made up a control group treated without any instruction to control the bladder volume. The remaining 21 patients in the experimental group were treated with a full bladder after drinking 450 mL of water an hour before treatment. We measured the bladder volume by CT and ultrasound at simulation to validate the accuracy of ultrasound. During the treatment period, we measured bladder volume weekly by ultrasound, for the experimental group, to evaluate the variation of the bladder volume. RESULTS: A significant correlation between the bladder volume measured by CT and ultrasound was observed. The bladder volume in the experimental group varied with each patient despite drinking the same amount of water. Although weekly variations of the bladder volume were very high, larger initial CT volumes were associated with larger mean weekly bladder volumes. The mean bladder volume was 299+/-155 mL in the experimental group, as opposed to 187+/-155 mL in the control group. Patients in experimental group experienced less acute urinary toxicities than in control group, but the difference was not statistically significant. A trend of reduced toxicity was observed with the increase of CT bladder volume. In patients with bladder volumes greater than 150 mL at simulation, toxicity rates of all grades were significantly lower than in patients with bladder volume less than 150 mL. Also, patients with a mean bladder volume larger than 100 mL during treatment showed a slightly reduced Grade 1 urinary toxicity rate compared to patients with a mean bladder volume smaller than 100 mL. CONCLUSION: Despite the large variability in bladder volume during the treatment period, treating patients with a full bladder reduced acute urinary toxicities in patients with prostate cancer. We recommend that patients with prostate cancer undergo treatment with a full bladder.
Asunto(s)
IncidenciaRESUMEN
The purpose of this study was to design and construct an ultrasound phantom for volume calibration and evaluate the volume measurement accuracy of a 2 dimensional ultrasonic system. Ultrasound phantom was designed, constructed and tested. The phantom consisted of a background material and a target. The background was made by mixing agarose gel with water. A target, made with an elastic material, was filled with water to vary its volume and shape and inserted into background material. To evaluate accuracy of a 2 dimensional ultrasonic system (128XP, ACUSON), three different shapes of targets (a sphere, 2 ellipsoids and a triangular prism) were constructed. In case of ellipsoid shape, two targets, one with same size length and width (ellipsoid 1) and another with the length 2 times longer than width (ellipsoid 2) were examined. The target volumes of each shape were varied from 94cc to 450cc and measurement accuracy was examined. The volume difference between the real and measured target of the sphere shape ranged between 6.7 and 11%. For the ellipsoid targets, the differences ranged from 9.2 to 10.5% with ellipsoid 1 and 25.7% with ellipsoid 2. The volume difference of the triangular prism target ranged between 20.8 and 35%. An easy and simple method of constructing an ultrasound phantom was introduced and it was possible to check the volume measurement accuracy of an ultrasound system.
Asunto(s)
Calibración , Sefarosa , Ultrasonido , AguaRESUMEN
The aim of this study is to introduce the accuracy of Ir-192 source's apparent activity using the well-type chamber and the Farmer-type ionization chamber in the high dose rate brachytherapy. We measured the apparent activity of Ir-192 that each medical center in the country has and the apparent activity of calibration certificate provided by manufacturer is compared with that by our experimental measurement. The number of sources used for the activity comparison was 5. The accuracy of the measured activity was in the range of -2.8% to -1.0% and -2.1% to 0.2% for the Farmer-type chamber system (Jig) and for the well-type, respectively. The maximum difference was within 1.0% for comparison with two calibration's tool. Our results demonstrate that well-type chamber as wall as Farmer-type chamber is a appropriate system as the routine source calibration procedures in HDR brachytherapy. Whenever a new source is installed to use in clinics, by periods, a source calibration should be carried out.
Asunto(s)
Braquiterapia , CalibraciónRESUMEN
Various techniques were evaluated to determine the best method for reducing small bowel involvement in pelvic irradiation. Fourteen patients receiving radiation in pelvic area were enrolled for this study. Five sets of small bowel images were obtained. Patients were positioned on a simulation couch with full bladder in prone and supine positions and 2 sets of images were taken. Then they were asked to empty their bladder and 2 sets of images were taken in prone and supine positions. A belly board device (BBD) was placed and one set of images was obtained. Using a software, the area of small bowel inside treatment field was contoured, measured, and analyzed. In both full and empty bladder cases, small bowel area reduction was observed in prone position as compared to supine position. Especially statistically significant reduction is noted in lateral film. An average decreases of 13% in PA and 26% in lateral direction were noted with bladder distention as compared to empty bladder. With the use of BBD for empty bladder, a significant reduction of 62.8+/-27.1% and 63.1+/-32.9% in PA and lateral directions were observed as compared to without BBD in prone position, respectively. In conclusion, the best sparing of small bowel concerning the area included in the treatment fields was achieved with BBD in prone position with empty bladder. However, further reduction is expected if the bladder was filled fully because the analysed data with empty vs full bladder study shows increased sparing of small bowel with distended bladder.
Asunto(s)
Humanos , Posición Prona , Posición Supina , Vejiga UrinariaRESUMEN
PURPOSE: To evaluate the movement of surgical clips implanted in breast tumor bed during normal breathing. MATERIALS AND METHODS: Seven patients receiving breast post-operative radiotherapy were selected for this study. Each patient was simulated in a common treatment position. Fluoroscopic images were recorded every 0.033 s, 30 frames per 1 second, for 10 seconds in anterior to posterior (AP), lateral, and tangential direction except one patient's images which were recorded as a rate of 15 frames per second. The movement of surgical clips was recorded and measured, thereby calculated maximal displacement of each clip in AP, lateral, tangential, and superior to inferior (SI) direction. For the comparison, we also measured the movement of diaphragm in SI direction. RESULTS: From AP direction's images, average movement of surgical clips in lateral and SI direction was 0.8+/-0.5 mm and 0.9+/-0.2 mm and maximal movement was 1.9 mm and 1.2 mm. Surgical clips in lateral direction's images were averagely moved 1.3+/-0.7 mm and 1.3+/-0.5 mm in AP and SI direction with 2.6 mm and 2.6 mm maximal movement in each direction. In tangential direction's images, average movement of surgical clips and maximal movement was 1.2+/-0.5 mm and 2.4 mm in tangential direction and 0.9+/-0.4 mm and 1.7 mm in SI direction. Diaphragm was averagely moved 14.0+/-2.4 mm and 18.8 mm maximally in SI direction. CONCLUSION: The movement of clips caused by breathing was not as significant as the movement of diaphragm. And all surgical clip movements were within 3 mm in all directions. These results suggest that for breast radiotherapy, it may not necessary to use breath-holding technique or devices to control breath.
Asunto(s)
Humanos , Neoplasias de la Mama , Mama , Diafragma , Radioterapia , Respiración , Instrumentos QuirúrgicosRESUMEN
PURPOSE: To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. MATERIALS AND METHODS: From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range 34~74) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follows: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of 45~50.4 Gy (median: 50.4 Gy) over 5~5.5 weeks. Ir-192 HDR intracavitary brachytherapy (ICBT) was given after a total dose of 41.4 Gy. HDR-ICBT was performed twice a week, with a fraction point A dose of 4 Gy and median dose to point A was 28 Gy (range: 16~32 Gy) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT+ICBT) was 88 Gy10 (range: 77~94 Gy10). The median cumulative BED at ICRU 38 reference point (EBRT+ICBT) was 131 Gy3 (range: 122~140 Gy3) at point A, 109 Gy3 (range: 88~125 Gy3) at the rectum and 111 Gy3 (range: 91~123 Gy3) at the urinary bladder. Cisplatin (60 mg/m2) and 5-FU (1,000 mg/m2) was administered intravenously at 3 weeks interval from the first day of radiation for median 5 (range: 2~6) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range: 8~50 months). RESULTS: The complete response rate after concurrent chemoradiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure rate was 13% and distant metastatic rate was 3.3%. The crude rate of minor hematologic complications (RTOG grade 1-2) occurred in 3 patients (10%) and one patient had suffered from severe leukopenia (RTOG grade 4) during concurrent treatment. Acute minor enterocolitis (RTOG grade 1-2) occurred in 11 patients (37%) and one patient (3%) was suffered from colon perforation during radiation therapy. Late colitis of RTOG grade 1 occurred in 5 patients (15%). Acute cystitis of RTOG grade 1 occurred in 12 patients (40%) and late cystitis of RTOG grade 2 occurred in one patient (3%). No treatment related death was seen. CONCLUSION: The results of this study suggest that the concurrent chemoradiation therapy with HDR brachytherapy could be accepted as an effective and safe treatment for cervical cancer.
Asunto(s)
Humanos , Adenocarcinoma , Biopsia , Braquiterapia , Carcinoma de Células Escamosas , Cisplatino , Colitis , Colon , Cistitis , Supervivencia sin Enfermedad , Quimioterapia , Enterocolitis , Fluorouracilo , Estudios de Seguimiento , Leucopenia , Patología , Recto , Tomografía Computarizada por Rayos X , Vejiga Urinaria , Neoplasias del Cuello UterinoRESUMEN
PURPOSE: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. MATERIALS AND METHODS: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images. RESULTS: In 7/21 patients, anatomic structures on DRR image were different from the simulation image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. CONCLUSION: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.