Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Transfusion ; 63(9): 1633-1638, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37615329

RESUMEN

BACKGROUND: Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2)-infected patients exhibit disease ranging from asymptomatic to severe pneumonia, multi-organ failure, and death. convalescent COVID plasma (CCP) from recovered patients with high levels of neutralizing antibodies has demonstrated therapeutic efficacy to reduce the morbidity of coronavirus disease 2019 (COVID-19) in some studies. The development of assays to characterize the activity of CCP to neutralize SARS-CoV-2 infectivity offers the possibility to improve potential therapeutic efficacy. Lyophilization of CCP may increase the availability of this therapy. We hypothesized that SARS-CoV-2 antibody profiles of pooled lyophilized pathogen-reduced CCP from COVID-19-recovered blood donors retains virus-neutralizing efficacy as reported for frozen pathogen-reduced CCP. METHODS: Pooled lyophilized pathogen-reduced plasma was prepared from recovered COVID plasma donors. Antibodies to SARS-CoV-2 were characterized in each donor plasma prior to pathogen reduction and lyophilization and after lyophilization of individual CCP, and in the lyophilized CCP pool. Several complimentary assays were used to characterize antibody levels, neutralizing capacity, and the spectrum of antigen reactivity. The mean values for individual plasma samples and the value in the pool were compared. RESULTS: The mean ratio for antibody binding to SARS-CoV-2 antigens before and after treatment was 0.95 ± 0.22 mean fluorescent intensity (MFI) units. Antibody activity to an array of influenza virus antigens demonstrated a mean activity ratio of 0.92 ± 0.12 MFI before and after treatment. CONCLUSIONS: The antibody activity in pooled pathogen-reduced lyophilized CCPs demonstrated minimal impact due to pathogen reduction treatment and lyophilization.


Asunto(s)
COVID-19 , Furocumarinas , Humanos , SARS-CoV-2 , COVID-19/terapia , Anticuerpos Neutralizantes
2.
Transfusion ; 62(3): 570-583, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35128658

RESUMEN

BACKGROUND: COVID-19 convalescent plasma (CCP), from donors recovered from severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection, is one of the limited therapeutic options currently available for the treatment of critically ill patients with COVID-19. There is growing evidence that CCP may reduce viral loads and disease severity; and reduce mortality. However, concerns about the risk of transfusion-transmitted infections (TTI) and other complications associated with transfusion of plasma, remain. Amotosalen/UVA pathogen reduction treatment (A/UVA-PRT) of plasma offers a mitigation of TTI risk, and when combined with pooling has the potential to increase the diversity of the polyclonal SARS-CoV-2 neutralizing antibodies. STUDY DESIGN AND METHODS: This study assessed the impact of A/UVA-PRT on SARS-CoV-2 antibodies in 42 CCP using multiple complimentary assays including antigen binding, neutralizing, and epitope microarrays. Other mediators of CCP efficacy were also assessed. RESULTS: A/UVA-PRT did not negatively impact antibodies to SARS-CoV-2 and other viral epitopes, had no impact on neutralizing activity or other potential mediators of CCP efficacy. Finally, immune cross-reactivity with other coronavirus antigens was observed raising the potential for neutralizing activity against other emergent coronaviruses. CONCLUSION: The findings of this study support the selection of effective CCP combined with the use of A/UVA-PRT in the production of CCP for patients with COVID-19.


Asunto(s)
COVID-19 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , COVID-19/terapia , Furocumarinas , Humanos , Inmunización Pasiva , SARS-CoV-2 , Sueroterapia para COVID-19
3.
Transfusion ; 62(10): 1997-2011, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36054476

RESUMEN

BACKGROUND: Efficacy of donated COVID-19 convalescent plasma (dCCP) is uncertain and may depend on antibody titers, neutralizing capacity, timing of administration, and patient characteristics. STUDY DESIGN AND METHODS: In a single-center hypothesis-generating prospective case-control study with 1:2 matched dCCP recipients to controls according to disease severity at day 1, hospitalized adults with COVID-19 pneumonia received 2 × 200 ml pathogen-reduced treated dCCP from 2 different donors. We evaluated severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies in COVID-19 convalescent plasma donors and recipients using multiple antibody assays including a Coronavirus antigen microarray (COVAM), and binding and neutralizing antibody assays. Outcomes were dCCP characteristics, antibody responses, 28-day mortality, and dCCP -related adverse events in recipients. RESULTS: Eleven of 13 dCCPs (85%) contained neutralizing antibodies (nAb). PRT did not affect dCCP antibody activity. Fifteen CCP recipients and 30 controls (median age 64 and 65 years, respectively) were enrolled. dCCP recipients received 2 dCCPs from 2 different donors after a median of one hospital day and 11 days after symptom onset. One dCCP recipient (6.7%) and 6 controls (20%) died (p = 0.233). We observed no dCCP-related adverse events. Transfusion of unselected dCCP led to heterogeneous SARS CoV-2 antibody responses. COVAM clustered dCCPs in 4 distinct groups and showed endogenous immune responses to SARS-CoV-2 antigens over 14-21 days post dCCP in all except 4 immunosuppressed recipients. DISCUSSION: PRT did not impact dCCP anti-virus neutralizing activity. Transfusion of unselected dCCP did not impact survival and had no adverse effects. Variable dCCP antibodies and post-transfusion antibody responses indicate the need for controlled trials using well-characterized dCCP with informative assays.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anciano , Anticuerpos Neutralizantes , Anticuerpos Antivirales , COVID-19/terapia , Estudios de Casos y Controles , Humanos , Inmunización Pasiva , Persona de Mediana Edad , Sueroterapia para COVID-19
4.
Proc Natl Acad Sci U S A ; 115(6): 1250-1255, 2018 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-29358368

RESUMEN

Oral fluid (OF) is a highly effective substrate for population-based HIV screening efforts, as it is noninfectious and significantly easier to collect than blood. However, anti-HIV antibodies are found at far lower concentrations in OF compared with blood, leading to poor sensitivity and a longer period of time from infection to detection threshold. Thus, despite its inherent advantages in sample collection, OF is not widely used for population screening. Here we report the development of an HIV OF assay based on Antibody Detection by Agglutination-PCR (ADAP) technology. This assay is 1,000-10,000 times more analytically sensitive than clinical enzyme-linked immunoassays (EIAs), displaying both 100% clinical sensitivity and 100% specificity for detecting HIV antibodies within OF samples. We show that the enhanced analytical sensitivity enables this assay to correctly identify HIV-infected individuals otherwise missed by current OF assays. We envision that the attributes of this improved HIV OF assay can increase testing rates of at-risk individuals while enabling diagnosis and treatment at an earlier time point.


Asunto(s)
Anticuerpos Anti-VIH/genética , Infecciones por VIH/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , Saliva/virología , Aglutinación , ADN/química , Diagnóstico Precoz , Anticuerpos Anti-VIH/análisis , Proteína p24 del Núcleo del VIH/genética , Proteína gp120 de Envoltorio del VIH/genética , Proteína gp41 de Envoltorio del VIH/genética , Infecciones por VIH/prevención & control , Humanos , Tamizaje Masivo/métodos , Sensibilidad y Especificidad , Flujo de Trabajo
5.
J Am Chem Soc ; 138(34): 10722-5, 2016 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-27454154

RESUMEN

We report a non-destructive biochemical technique, termed "Glyco-seek", for analysis of O-GlcNAcylated proteins. Glyco-seek combines chemoenzymatic labeling, proximity ligation, and quantitative polymerase chain reaction to detect O-GlcNAcylated proteins with ultrahigh sensitivity. Our glycan-specific assay can be paired with traditional proximity ligation assays to simultaneously determine the change in total protein levels. We show that Glyco-seek detects attomoles of glycoproteins of interest from cell lysates, with sensitivity several orders of magnitude higher than that of current techniques. We used the method to directly assay the O-GlcNAcylation status of a low-abundance transcription factor from cell lysates without need for isolation or enrichment.


Asunto(s)
Glicoproteínas/metabolismo , Límite de Detección , Acetilglucosamina/metabolismo , Azidas/química , Química Clic , Glicoproteínas/química , Glicosilación , Reacción en Cadena de la Polimerasa
6.
Bioorg Med Chem ; 24(20): 4791-4800, 2016 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-27283789

RESUMEN

The generation of homogeneously glycosylated proteins is essential for defining glycoform-specific activity and improving protein-based therapeutics. We present a novel glycodendron prosthetic which can be site-selectively appended to recombinant proteins to create 'N-glycosylated' glycoprotein mimics. Using computational modeling, we designed the dendrimer scaffold and protein attachment point to resemble the native N-glycan architecture. Three piperidine-melamine glycodendrimers were synthesized via a chemoenzymatic route and attached to human growth hormone and the Fc region of human IgG. These products represent a new class of engineered biosimilars bearing novel glycodendrimer structures.


Asunto(s)
Dendrímeros/química , Piperidinas/química , Polisacáridos/química , Proteínas/química , Dendrímeros/síntesis química , Humanos , Estructura Molecular , Triazinas/química
7.
J Am Chem Soc ; 137(33): 10452-5, 2015 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-26280358

RESUMEN

Reagents for detecting post-translational modifications in the context of their protein scaffold are powerful tools, but are challenging to develop for glycosylated epitopes. We describe a strategy for detecting protein-specific glycosylation through the use of cyclooctyne-aptamer conjugates. These molecules selectively ligate to azidosugar-labeled glycans exclusively on a target protein on live cells. We characterized aptamer conjugates against two different cell surface glycoproteins and show that these reagents are amenable to detecting protein sialoforms by mass spectrometry, Western blotting, and flow cytometry. Given the abundance of aptamers that bind cell surface targets, we expect this technology will be a useful platform for investigating the roles of protein-specific glycosylation in various cellular contexts.


Asunto(s)
Glicoproteínas/metabolismo , Coloración y Etiquetado/métodos , Aptámeros de Nucleótidos/metabolismo , Supervivencia Celular , Humanos , Células Jurkat
9.
EBioMedicine ; 104: 105144, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38723553

RESUMEN

BACKGROUND: Two or more autoantibodies against either insulin (IAA), glutamic acid decarboxylase (GADA), islet antigen-2 (IA-2A) or zinc transporter 8 (ZnT8A) denote stage 1 (normoglycemia) or stage 2 (dysglycemia) type 1 diabetes prior to stage 3 type 1 diabetes. Automated multiplex Antibody Detection by Agglutination-PCR (ADAP) assays in two laboratories were compared to single plex radiobinding assays (RBA) to define threshold levels for diagnostic specificity and sensitivity. METHODS: IAA, GADA, IA-2A and ZnT8A were analysed in 1504 (54% females) population based controls (PBC), 456 (55% females) doctor's office controls (DOC) and 535 (41% females) blood donor controls (BDC) as well as in 2300 (48% females) patients newly diagnosed (1-10 years of age) with stage 3 type 1 diabetes. The thresholds for autoantibody positivity were computed in 100 10-fold cross-validations to separate patients from controls either by maximizing the χ2-statistics (chisq) or using the 98th percentile of specificity (Spec98). Mean and 95% CI for threshold, sensitivity and specificity are presented. FINDINGS: The ADAP ROC curves of the four autoantibodies showed comparable AUC in the two ADAP laboratories and were higher than RBA. Detection of two or more autoantibodies using chisq showed 0.97 (0.95, 0.99) sensitivity and 0.94 (0.91, 0.97) specificity in ADAP compared to 0.90 (0.88, 0.95) sensitivity and 0.97 (0.94, 0.98) specificity in RBA. Using Spec98, ADAP showed 0.92 (0.89, 0.95) sensitivity and 0.99 (0.98, 1.00) specificity compared to 0.89 (0.77, 0.86) sensitivity and 1.00 (0.99, 1.00) specificity in the RBA. The diagnostic sensitivity and specificity were higher in PBC compared to DOC and BDC. INTERPRETATION: ADAP was comparable in two laboratories, both comparable to or better than RBA, to define threshold levels for two or more autoantibodies to stage type 1 diabetes. FUNDING: Supported by The Leona M. and Harry B. Helmsley Charitable Trust (grant number 2009-04078), the Swedish Foundation for Strategic Research (Dnr IRC15-0067) and the Swedish Research Council, Strategic Research Area (Dnr 2009-1039). AL was supported by the DiaUnion collaborative study, co-financed by EU Interreg ÖKS, Capital Region of Denmark, Region Skåne and the Novo Nordisk Foundation.


Asunto(s)
Autoanticuerpos , Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/inmunología , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/sangre , Autoanticuerpos/sangre , Autoanticuerpos/inmunología , Femenino , Masculino , Niño , Preescolar , Lactante , Transportador 8 de Zinc/inmunología , Sensibilidad y Especificidad , Proteínas Tirosina Fosfatasas Clase 8 Similares a Receptores/inmunología , Glutamato Descarboxilasa/inmunología , Curva ROC , Tamizaje Masivo/métodos
10.
SLAS Technol ; 27(1): 26-31, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35058202

RESUMEN

Screening for islet autoantibody markers to identify individuals who are at high risk for developing type 1 diabetes (T1D), often years in advance of clinical symptoms, is both a challenge and a necessity. Identifying high-risk individuals not only reduces hospitalization and rates of life-threatening diabetes ketoacidosis (DKA), but also directs enrollment into prevention trials that require patients who are in the early stages of disease. Here we describe an automated high-throughput multiplex islet autoantibody assay that integrates antibody detection by agglutination-PCR (ADAP) chemistry on the Hamilton Microlab STAR liquid handling platform. The automated system features on-deck thermal cycling and plate sealing to minimize the level of human intervention. The automated multiplex ADAP T1D assay performed similarly to that of manual methods using two distinct cohorts of clinical specimens obtained from the Lucile Packard Children's Hospital at Stanford University and the 2018 Islet Autoantibody Standardization Program (IASP). Notably, the automated assay requires only 4 µL of serum sample for the simultaneous analysis of GAD, IA-2 and insulin autoantibodies. Up to 96 samples may be processed in as little as 3 hours, and the only user intervention required is to transfer a final sealed 96-well plate containing PCR amplicons onto a quantitative PCR (RT-qPCR) instrument for quantification. The automated system is particularly well suited for large-scale analysis of islet autoantibodies in a reproducible, timely, and cost-effective manner.


Asunto(s)
Diabetes Mellitus Tipo 1 , Aglutinación , Autoanticuerpos , Automatización , Niño , Diabetes Mellitus Tipo 1/diagnóstico , Humanos , Reacción en Cadena de la Polimerasa Multiplex
11.
J Immunol Methods ; 506: 113265, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35358496

RESUMEN

Multiplex Antibody-Detection by Agglutination-PCR (ADAP) assay was compared to singleplex standard radiobinding assays (RBA) to detect autoantibodies against insulin (IAA), GAD65 (GADA), islet antigen-2 (IA-2A), ZnT8 (ZnT8A) and tissue transglutaminase (TGA). Serum samples from 273 (114F/158M), 15-73 years of age healthy controls and 227 (109F/118M) newly diagnosed type 1 diabetes children, 1-11 years of age, were analyzed in both assay systems.The original WHO standard 97/550 and in-house reference standards for RBA were compared to ADAP. The ADAP and RBA generated parallel reference standards in all assays except TGA. Lower detection limits were observed in the ADAP assay for GADA,IAA and ZnT8A, markedly for TGA, but not for IA-2A. The Receiver Operating Characteristics (ROC) curve AUC analyses for pairwise comparison of ADAP with RBA showed no difference for GADA (n.s.), ADAP greater AUC for IAA (p = 0.005), RBA greater AUC for IA-2A (p = 0.0004) and ZnT8A (p < 0.0001) while ADAP TGA had a greater AUC compared to both RBA TGA-IgG (p < 0.0001) and TGA-IgA (p < 0.0001). These data suggest that the ADAP and RBA assays are comparable with equal performance for GADA, better ADAP performance for IAA while the RBA showed better performance in both IA-2A and ZnT8A associated with greater heterogeneity in autoantibody levels. The simultaneous analysis of 5 different autoantibodies by ADAP in sample volume reduced to only 4 µL and at an increased lower detection limit in all assays except IA-2A makes the ADAP automated autoantibody assay a distinct advantage for high throughput screening.


Asunto(s)
Enfermedad Celíaca , Diabetes Mellitus Tipo 1 , Aglutinación , Autoanticuerpos , Enfermedad Celíaca/diagnóstico , Niño , Preescolar , Diabetes Mellitus Tipo 1/diagnóstico , Glutamato Descarboxilasa , Humanos , Lactante , Reacción en Cadena de la Polimerasa
12.
Nat Commun ; 13(1): 4212, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35864104

RESUMEN

An easily implementable serological assay to accurately detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) neutralizing antibodies is urgently needed to better track herd immunity, vaccine efficacy and vaccination rates. Herein, we report the Split-Oligonucleotide Neighboring Inhibition Assay (SONIA) which uses real-time qPCR to measure the ability of neutralizing antibodies to block binding between DNA-barcoded viral spike protein subunit 1 and the human angiotensin-converting enzyme 2 receptor protein. The SONIA neutralizing antibody assay using finger-prick dried blood spots displays 91-97% sensitivity and 100% specificity in comparison to the live-virus neutralization assays using matched serum specimens for multiple SARS-CoV-2 variants-of-concern. The multiplex version of this neutralizing antibody assay, using easily collectable finger-prick dried blood spots, can be a valuable tool to help reveal the impact of age, pre-existing health conditions, waning immunity, different vaccination schemes and the emergence of new variants-of-concern.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Humanos , Pruebas de Neutralización , Reacción en Cadena de la Polimerasa , SARS-CoV-2/genética , Glicoproteína de la Espiga del Coronavirus
13.
Sci Rep ; 10(1): 20188, 2020 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-33214612

RESUMEN

Accurate surveillance of coronavirus disease 2019 (COVID-19) incidence requires large-scale testing of the population. Current testing methods require in-person collection of biospecimens by a healthcare worker, limiting access of individuals who do not have access to testing facilities while placing both patients and healthcare workers at risk of exposure to infection. We report the development and validation of a at-home finger-prick dried blood spot collection kit and an analysis method. We demonstrated 100% sensitivity and specificity using at-home collected specimens across the US. Such methods may facilitate the conduct of unbiased serosurveys within hard to reach populations and help reduce the sample collection burden of serological testing on both health care systems and individuals alike.


Asunto(s)
Prueba Serológica para COVID-19/métodos , Pruebas con Sangre Seca/normas , Juego de Reactivos para Diagnóstico/normas , Adulto , Anciano , Anciano de 80 o más Años , Prueba Serológica para COVID-19/normas , Pruebas con Sangre Seca/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
14.
SLAS Technol ; 25(6): 545-552, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32815769

RESUMEN

As of July 22, 2020, more than 14.7 million infections of SARS-CoV-2, the virus responsible for Coronavirus Disease 2019 (COVID-19), have been confirmed globally. Serological assays are essential for community screening, assessing infection prevalence, aiding identification of infected patients, and enacting appropriate treatment and quarantine protocols in the battle against this rapidly expanding pandemic. Antibody detection by agglutination-PCR (ADAP) is a pure solution phase immunoassay that generates a PCR amplifiable signal when patient antibodies agglutinate DNA-barcoded antigen probes into a dense immune complex. Here, we present an ultrasensitive and high-throughput automated liquid biopsy assay based on the Hamilton Microlab ADAP STAR automated liquid-handling platform, which was developed and validated for the qualitative detection of total antibodies against spike protein 1 (S1) of SARS-CoV-2 that uses as little as 4 µL of serum. To assess the clinical performance of the ADAP assay, 57 PCR-confirmed COVID-19 patients and 223 control patients were tested. The assay showed a sensitivity of 98% (56/57) and a specificity of 99.55% (222/223). Notably, the SARS-CoV-2-negative control patients included individuals with other common coronaviral infections, such as CoV-NL63 and CoV-HKU, which did not cross-react. In addition to high performance, the hands-free automated workstation enabled high-throughput sample processing to reduce screening workload while helping to minimize analyst contact with biohazardous samples. Therefore, the ADAP STAR liquid-handling workstation can be used as a valuable tool to address the COVID-19 global pandemic.


Asunto(s)
Alphacoronavirus/inmunología , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Coronavirus Humano NL63/inmunología , SARS-CoV-2/fisiología , Glicoproteína de la Espiga del Coronavirus/inmunología , Animales , Automatización de Laboratorios , Quirópteros , Técnicas de Laboratorio Clínico , Reacciones Cruzadas , Ensayos Analíticos de Alto Rendimiento , Humanos , Inmunoensayo , Pandemias , Reacción en Cadena de la Polimerasa , Procedimientos Quirúrgicos Robotizados , Sensibilidad y Especificidad
15.
medRxiv ; 2020 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-32577696

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has led to more than 4 million confirmed infections worldwide and over 300,000 deaths. While Remdesivir has recently received FDA emergency use authorization for treatment of SARS-CoV-2 infection, convalescent plasma (CP) with high titers of SARS-CoV-2 neutralizing antibodies (NAbs) from recovered donors remains a promising and widely accessible method to mitigate severe disease symptoms. Here, we describe the development and validation of a cell-free neutralization PCR assay using SARS-CoV-2 spike protein S1 and human ACE2 receptor-DNA conjugates. By comparing with samples collected prior to the outbreak, we confirmed that NAbs were specifically detected in COVID-19 cases. Using our unique assay, the NAb signals are detectable as early as 10 days after onset of symptoms and continue to rise, plateauing after 18 days. Notably, we showed that the use of licensed pathogen reduction technology to inactivate potentially contaminating infectious pathogens in CP did not alter NAb signals, paving a path to safely administer effective CP therapies. The described neutralization PCR assay can serve as a qualification tool to easily identify suitable CP donors of a potentially lifesaving therapy. In addition, this assay tool is readily deployable in standard laboratories with biosafety level 2 capability, and can yield results within 2-3 hr. This advancement can facilitate research on factors driving diverse COVID-19 disease manifestations, and to evaluate the impact of various CP processing protocols on CP therapeutic efficacy.

16.
PLoS One ; 15(11): e0242049, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33186361

RESUMEN

Islet autoantibodies are predominantly measured by radioassay to facilitate risk assessment and diagnosis of type 1 diabetes. However, the reliance on radioactive components, large sample volumes and limited throughput renders radioassay testing costly and challenging. We developed a multiplex analysis platform based on antibody detection by agglutination-PCR (ADAP) for the sample-sparing measurement of GAD, IA-2 and insulin autoantibodies/antibodies in 1 µL serum. The assay was developed and validated in 7 distinct cohorts (n = 858) with the majority of the cohorts blinded prior to analysis. Measurements from the ADAP assay were compared to radioassay to determine correlation, concordance, agreement, clinical sensitivity and specificity. The average overall agreement between ADAP and radioassay was above 91%. The average clinical sensitivity and specificity were 96% and 97%. In the IASP 2018 workshop, ADAP achieved the highest sensitivity of all assays tested at 95% specificity (AS95) rating for GAD and IA-2 autoantibodies and top-tier performance for insulin autoantibodies. Furthermore, ADAP correctly identified 95% high-risk individuals with two or more autoantibodies by radioassay amongst 39 relatives of T1D patients tested. In conclusion, the new ADAP assay can reliably detect the three cardinal islet autoantibodies/antibodies in 1µL serum with high sensitivity. This novel assay may improve pediatric testing compliance and facilitate easier community-wide screening for islet autoantibodies.


Asunto(s)
Aglutinación/inmunología , Autoanticuerpos/inmunología , Diabetes Mellitus Tipo 1/inmunología , Islotes Pancreáticos/inmunología , Adolescente , Adulto , Femenino , Glutamato Descarboxilasa/inmunología , Humanos , Anticuerpos Insulínicos/inmunología , Masculino , Tamizaje Masivo , Reacción en Cadena de la Polimerasa/métodos , Sensibilidad y Especificidad , Adulto Joven
17.
ACS Cent Sci ; 2(3): 139-147, 2016 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-27064772

RESUMEN

Antibodies are widely used biomarkers for the diagnosis of many diseases. Assays based on solid-phase immobilization of antigens comprise the majority of clinical platforms for antibody detection, but can be undermined by antigen denaturation and epitope masking. These technological hurdles are especially troublesome in detecting antibodies that bind nonlinear or conformational epitopes, such as anti-insulin antibodies in type 1 diabetes patients and anti-thyroglobulin antibodies associated with thyroid cancers. Radioimmunoassay remains the gold standard for these challenging antibody biomarkers, but the limited multiplexability and reliance on hazardous radioactive reagents have prevented their use outside specialized testing facilities. Here we present an ultrasensitive solution-phase method for detecting antibodies, termed antibody detection by agglutination-PCR (ADAP). Antibodies bind to and agglutinate synthetic antigen-DNA conjugates, enabling ligation of the DNA strands and subsequent quantification by qPCR. ADAP detects zepto- to attomoles of antibodies in 2 µL of sample with a dynamic range spanning 5-6 orders of magnitude. Using ADAP, we detected anti-thyroglobulin autoantibodies from human patient plasma with a 1000-fold increased sensitivity over an FDA-approved radioimmunoassay. Finally, we demonstrate the multiplexability of ADAP by simultaneously detecting multiple antibodies in one experiment. ADAP's combination of simplicity, sensitivity, broad dynamic range, multiplexability, and use of standard PCR protocols creates new opportunities for the discovery and detection of antibody biomarkers.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA