Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Magn Reson ; 25(1): 78, 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38093273

RESUMEN

BACKGROUND: While the microstructure of the left ventricle (LV) has been largely described, only a few studies investigated the right ventricular insertion point (RVIP). It was accepted that the aggregate cardiomyocytes organization was much more complex due to the intersection of the ventricular cavities but a precise structural characterization in the human heart was lacking even if clinical phenotypes related to right ventricular wall stress or arrhythmia were observed in this region. METHODS: MRI-derived anatomical imaging (150 µm3) and diffusion tensor imaging (600 µm3) were performed in large mammalian whole hearts (human: N = 5, sheep: N = 5). Fractional anisotropy, aggregate cardiomyocytes orientations and tractography were compared within both species. Aggregate cardiomyocytes orientation on one ex-vivo sheep whole heart was then computed using structure tensor imaging (STI) from 21 µm isotropic acquisition acquired with micro computed tomography (MicroCT) imaging. Macroscopic and histological examination were performed. Lastly, experimental cardiomyocytes orientation distribution was then compared to the usual rule-based model using electrophysiological (EP) modeling. Electrical activity was modeled with the monodomain formulation. RESULTS: The RVIP at the level of the inferior ventricular septum presented a unique arrangement of aggregate cardiomyocytes. An abrupt, mid-myocardial change in cardiomyocytes orientation was observed, delimiting a triangle-shaped region, present in both sheep and human hearts. FA's histogram distribution (mean ± std: 0.29 ± 0.06) of the identified region as well as the main dimension (22.2 mm ± 5.6 mm) was found homogeneous across samples and species. Averaged volume is 0.34 cm3 ± 0.15 cm3. Both local activation time (LAT) and morphology of pseudo-ECGs were strongly impacted with delayed LAT and change in peak-to-peak amplitude in the simulated wedge model. CONCLUSION: The study was the first to describe the 3D cardiomyocytes architecture of the basal inferoseptal left ventricle region in human hearts and identify the presence of a well-organized aggregate cardiomyocytes arrangement and cardiac structural discontinuities. The results might offer a better appreciation of clinical phenotypes like RVIP-late gadolinium enhancement or uncommon idiopathic ventricular arrhythmias (VA) originating from this region.


Asunto(s)
Imagen de Difusión Tensora , Ventrículos Cardíacos , Humanos , Animales , Ovinos , Ventrículos Cardíacos/diagnóstico por imagen , Imagen de Difusión Tensora/métodos , Medios de Contraste , Microtomografía por Rayos X , Valor Predictivo de las Pruebas , Gadolinio , Miocitos Cardíacos/fisiología , Arritmias Cardíacas , Mamíferos
2.
Am J Physiol Heart Circ Physiol ; 322(6): H936-H952, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35302879

RESUMEN

Cardiac fiber direction is an important factor determining the propagation of electrical activity, as well as the development of mechanical force. In this article, we imaged the ventricles of several species with special attention to the intraventricular septum to determine the functional consequences of septal fiber organization. First, we identified a dual-layer organization of the fiber orientation in the intraventricular septum of ex vivo sheep hearts using diffusion tensor imaging at high field MRI. To expand the scope of the results, we investigated the presence of a similar fiber organization in five mammalian species (rat, canine, pig, sheep, and human) and highlighted the continuity of the layer with the moderator band in large mammalian species. We implemented the measured septal fiber fields in three-dimensional electromechanical computer models to assess the impact of the fiber orientation. The downward fibers produced a diamond activation pattern superficially in the right ventricle. Electromechanically, there was very little change in pressure volume loops although the stress distribution was altered. In conclusion, we clarified that the right ventricular septum has a downwardly directed superficial layer in larger mammalian species, which can have modest effects on stress distribution.NEW & NOTEWORTHY A dual-layer organization of the fiber orientation in the intraventricular septum was identified in ex vivo hearts of large mammals. The RV septum has a downwardly directed superficial layer that is continuous with the moderator band. Electrically, it produced a diamond activation pattern. Electromechanically, little change in pressure volume loops were noticed but stress distribution was altered. Fiber distribution derived from diffusion tensor imaging should be considered for an accurate strain and stress analysis.


Asunto(s)
Imagen de Difusión Tensora , Tabique Interventricular , Animales , Diamante , Perros , Ventrículos Cardíacos , Mamíferos , Miocardio , Ratas , Ovinos , Porcinos , Tabique Interventricular/diagnóstico por imagen
3.
Comput Biol Med ; 156: 106696, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36870172

RESUMEN

Mechanoelectric feedback (MEF) in the heart operates through several mechanisms which serve to regulate cardiac function. Stretch activated channels (SACs) in the myocyte membrane open in response to cell lengthening, while tension generation depends on stretch, shortening velocity, and calcium concentration. How all of these mechanisms interact and their effect on cardiac output is still not fully understood. We sought to gauge the acute importance of the different MEF mechanisms on heart function. An electromechanical computer model of a dog heart was constructed, using a biventricular geometry of 500K tetrahedral elements. To describe cellular behavior, we used a detailed ionic model to which a SAC model and an active tension model, dependent on stretch and shortening velocity and with calcium sensitivity, were added. Ventricular inflow and outflow were connected to the CircAdapt model of cardiovascular circulation. Pressure-volume loops and activation times were used for model validation. Simulations showed that SACs did not affect acute mechanical response, although if their trigger level was decreased sufficiently, they could cause premature excitations. The stretch dependence of tension had a modest effect in reducing the maximum stretch, and stroke volume, while shortening velocity had a much bigger effect on both. MEF served to reduce the heterogeneity in stretch while increasing tension heterogeneity. In the context of left bundle branch block, a decreased SAC trigger level could restore cardiac output by reducing the maximal stretch when compared to cardiac resynchronization therapy. MEF is an important aspect of cardiac function and could potentially mitigate activation problems.


Asunto(s)
Bloqueo de Rama , Calcio , Animales , Perros , Calcio/metabolismo , Corazón/fisiología , Arritmias Cardíacas , Ventrículos Cardíacos
4.
Circ Arrhythm Electrophysiol ; 15(5): e010384, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35323037

RESUMEN

BACKGROUND: Conventional mapping of focal ventricular arrhythmias relies on unipolar electrogram characteristics and early local activation times. Deep intramural foci are common and associated with high recurrence rates following catheter-based radiofrequency ablation. We assessed the accuracy of unipolar morphological patterns and mapping surface indices to predict the site and depth of ventricular arrhythmogenic focal sources. METHODS: An experimental beating-heart model used Langendorff-perfused, healthy swine hearts. A custom 56-pole electrode array catheter was positioned on the left ventricle. A plunge needle was placed perpendicular in the center of the grid to simulate arrhythmic foci at variable depths. Unipolar electrograms and local activation times were generated. Simulation models from 2 human hearts were also included with grids positioned simultaneously on the endocardium-epicardium from multiple left ventricular, septal, and outflow tract sites. RESULTS: A unipolar Q or QS complex lacks specificity for superficial arrhythmic foci, as this morphology pattern occupies a large surface area and is the predominant pattern as intramural depth increases without developing a R component. There is progressive displacement from the arrhythmic focus to the surface exit as intramural focus depth increases. A shorter total activation time over the overlying electrode array, larger surface area within initial 20 ms activation, and a dual surface breakout pattern all indicate a deep focus. CONCLUSIONS: Displacement from the focal intramural origin to the exit site on the mapping surface could lead to erroneous lesion delivery strategies. Traditional unipolar electrogram features lack specificity to predict the intramural arrhythmic source; however, novel endocardial-epicardial mapping surface indices can be used to determine the depth of arrhythmic foci.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Animales , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/patología , Arritmias Cardíacas/cirugía , Electrofisiología Cardíaca , Endocardio , Mapeo Epicárdico , Ventrículos Cardíacos , Pericardio , Porcinos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/patología , Taquicardia Ventricular/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA