Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Pediatr ; 23(Suppl 2): 657, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38977945

RESUMEN

BACKGROUND: The emergence of COVID-19 precipitated containment policies (e.g., lockdowns, school closures, etc.). These policies disrupted healthcare, potentially eroding gains for Sustainable Development Goals including for neonatal mortality. Our analysis aimed to evaluate indirect effects of COVID-19 containment policies on neonatal admissions and mortality in 67 neonatal units across Kenya, Malawi, Nigeria, and Tanzania between January 2019 and December 2021. METHODS: The Oxford Stringency Index was applied to quantify COVID-19 policy stringency over time for Kenya, Malawi, Nigeria, and Tanzania. Stringency increased markedly between March and April 2020 for these four countries (although less so in Tanzania), therefore defining the point of interruption. We used March as the primary interruption month, with April for sensitivity analysis. Additional sensitivity analysis excluded data for March and April 2020, modelled the index as a continuous exposure, and examined models for each country. To evaluate changes in neonatal admissions and mortality based on this interruption period, a mixed effects segmented regression was applied. The unit of analysis was the neonatal unit (n = 67), with a total of 266,741 neonatal admissions (January 2019 to December 2021). RESULTS: Admission to neonatal units decreased by 15% overall from February to March 2020, with half of the 67 neonatal units showing a decline in admissions. Of the 34 neonatal units with a decline in admissions, 19 (28%) had a significant decrease of ≥ 20%. The month-to-month decrease in admissions was approximately 2% on average from March 2020 to December 2021. Despite the decline in admissions, we found no significant changes in overall inpatient neonatal mortality. The three sensitivity analyses provided consistent findings. CONCLUSION: COVID-19 containment measures had an impact on neonatal admissions, but no significant change in overall inpatient neonatal mortality was detected. Additional qualitative research in these facilities has explored possible reasons. Strengthening healthcare systems to endure unexpected events, such as pandemics, is critical in continuing progress towards achieving Sustainable Development Goals, including reducing neonatal deaths to less than 12 per 1000 live births by 2030.


Asunto(s)
COVID-19 , Mortalidad Infantil , Análisis de Series de Tiempo Interrumpido , Humanos , COVID-19/epidemiología , COVID-19/prevención & control , COVID-19/mortalidad , Recién Nacido , Tanzanía/epidemiología , Kenia/epidemiología , Mortalidad Infantil/tendencias , Malaui/epidemiología , Nigeria/epidemiología , Admisión del Paciente/estadística & datos numéricos , Unidades de Cuidado Intensivo Neonatal , Hospitalización/estadística & datos numéricos , Pandemias , Lactante
2.
BMC Pediatr ; 23(Suppl 2): 655, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454369

RESUMEN

BACKGROUND: Each year an estimated 2.3 million newborns die in the first 28 days of life. Most of these deaths are preventable, and high-quality neonatal care is fundamental for surviving and thriving. Service readiness is used to assess the capacity of hospitals to provide care, but current health facility assessment (HFA) tools do not fully evaluate inpatient small and sick newborn care (SSNC). METHODS: Health systems ingredients for SSNC were identified from international guidelines, notably World Health Organization (WHO), and other standards for SSNC. Existing global and national service readiness tools were identified and mapped against this ingredients list. A novel HFA tool was co-designed according to a priori considerations determined by policymakers from four African governments, including that the HFA be completed in one day and assess readiness across the health system. The tool was reviewed by > 150 global experts, and refined and operationalised in 64 hospitals in Kenya, Malawi, Nigeria, and Tanzania between September 2019 and March 2021. RESULTS: Eight hundred and sixty-six key health systems ingredients for service readiness for inpatient SSNC were identified and mapped against four global and eight national tools measuring SSNC service readiness. Tools revealed major content gaps particularly for devices and consumables, care guidelines, and facility infrastructure, with a mean of 13.2% (n = 866, range 2.2-34.4%) of ingredients included. Two tools covered 32.7% and 34.4% (n = 866) of ingredients and were used as inputs for the new HFA tool, which included ten modules organised by adapted WHO health system building blocks, including: infrastructure, pharmacy and laboratory, medical devices and supplies, biomedical technician workshop, human resources, information systems, leadership and governance, family-centred care, and infection prevention and control. This HFA tool can be conducted at a hospital by seven assessors in one day and has been used in 64 hospitals in Kenya, Malawi, Nigeria, and Tanzania. CONCLUSION: This HFA tool is available open-access to adapt for use to comprehensively measure service readiness for level-2 SSNC, including respiratory support. The resulting facility-level data enable comparable tracking for Every Newborn Action Plan coverage target four within and between countries, identifying facility and national-level health systems gaps for action.


Asunto(s)
Países en Desarrollo , Calidad de la Atención de Salud , Recién Nacido , Humanos , Naciones Unidas , Tanzanía , Instituciones de Salud
3.
BMC Pediatr ; 23(Suppl 2): 656, 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38475761

RESUMEN

BACKGROUND: Service readiness tools are important for assessing hospital capacity to provide quality small and sick newborn care (SSNC). Lack of summary scoring approaches for SSNC service readiness means we are unable to track national targets such as the Every Newborn Action Plan targets. METHODS: A health facility assessment (HFA) tool was co-designed by Newborn Essential Solutions and Technologies (NEST360) and UNICEF with four African governments. Data were collected in 68 NEST360-implementing neonatal units in Kenya, Malawi, Nigeria, and Tanzania (September 2019-March 2021). Two summary scoring approaches were developed: a) standards-based, including items for SSNC service readiness by health system building block (HSBB), and scored on availability and functionality, and b) level-2 + , scoring items on readiness to provide WHO level-2 + clinical interventions. For each scoring approach, scores were aggregated and summarised as a percentage and equally weighted to obtain an overall score by hospital, HSBB, and clinical intervention. RESULTS: Of 1508 HFA items, 1043 (69%) were included in standards-based and 309 (20%) in level-2 + scoring. Sixty-eight neonatal units across four countries had median standards-based scores of 51% [IQR 48-57%] at baseline, with variation by country: 62% [IQR 59-66%] in Kenya, 49% [IQR 46-51%] in Malawi, 50% [IQR 42-58%] in Nigeria, and 55% [IQR 53-62%] in Tanzania. The lowest scoring was family-centred care [27%, IQR 18-40%] with governance highest scoring [76%, IQR 71-82%]. For level-2 + scores, the overall median score was 41% [IQR 35-51%] with variation by country: 50% [IQR 44-53%] in Kenya, 41% [IQR 35-50%] in Malawi, 33% [IQR 27-37%] in Nigeria, and 41% [IQR 32-52%] in Tanzania. Readiness to provide antibiotics by culture report was the highest-scoring intervention [58%, IQR 50-75%] and neonatal encephalopathy management was the lowest-scoring [21%, IQR 8-42%]. In both methods, overall scores were low (< 50%) for 27 neonatal units in standards-based scoring and 48 neonatal units in level-2 + scoring. No neonatal unit achieved high scores of > 75%. DISCUSSION: Two scoring approaches reveal gaps in SSNC readiness with no neonatal units achieving high scores (> 75%). Government-led quality improvement teams can use these summary scores to identify areas for health systems change. Future analyses could determine which items are most directly linked with quality SSNC and newborn outcomes.


Asunto(s)
Instituciones de Salud , Hospitales , Recién Nacido , Humanos , Tanzanía , Malaui , Kenia , Nigeria , Organización Mundial de la Salud
4.
BMC Pediatr ; 23(Suppl 2): 632, 2023 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-38098013

RESUMEN

BACKGROUND: Small and sick newborn care (SSNC) is critical for national neonatal mortality reduction targets by 2030. Investment cases could inform implementation planning and enable coordinated resource mobilisation. We outline development of an investment case for Tanzania to estimate additional financing for scaling up SSNC to 80% of districts as part of health sector strategies to meet the country's targets. METHODS: We followed five steps: (1) reviewed national targets, policies and guidelines; (2) modelled potential health benefits by increased coverage of SSNC using the Lives Saved Tool; (3) estimated setup and running costs using the Neonatal Device Planning and Costing Tool, applying two scenarios: (A) all new neonatal units and devices with optimal staffing, and (B) half new and half modifying, upgrading, or adding resources to existing neonatal units; (4) calculated budget impact and return on investment (ROI) and (5) identified potential financing opportunities. RESULTS: Neonatal mortality rate was forecast to fall from 20 to 13 per 1000 live births with scale-up of SSNC, superseding the government 2025 target of 15, and close to the 2030 Sustainable Development Goal 3.2 target of <12. At 85% endline coverage, estimated cumulative lives saved were 36,600 by 2025 and 80,000 by 2030. Total incremental costs were estimated at US$166 million for scenario A (US$112 million set up and US$54 million for running costs) and US$90 million for scenario B (US$65 million setup and US$25 million for running costs). Setup costs were driven by infrastructure (83%) and running costs by human resources (60%). Cost per capita was US$0.93 and the ROI is estimated to be between US$8-12 for every dollar invested. CONCLUSIONS: ROI for SSNC is higher compared to other health investments, noting many deaths averted followed by full lifespan. This is conservative since disability averted is not included. Budget impact analysis estimated a required 2.3% increase in total government health expenditure per capita from US$40.62 in 2020, which is considered affordable, and the government has already allocated additional funding. Our proposed five-step SSNC investment case has potential for other countries wanting to accelerate progress.


Asunto(s)
Mortalidad Infantil , Desarrollo Sostenible , Recién Nacido , Humanos , Tanzanía
5.
BMC Pediatr ; 23(Suppl 2): 572, 2023 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-37974092

RESUMEN

BACKGROUND: Health system shocks are increasing. The COVID-19 pandemic resulted in global disruptions to health systems, including maternal and newborn healthcare seeking and provision. Yet evidence on mitigation strategies to protect newborn service delivery is limited. We sought to understand what mitigation strategies were employed to protect small and sick newborn care (SSNC) across 65 facilities Kenya, Malawi, Nigeria and Tanzania, implementing with the NEST360 Alliance, and if any could be maintained post-pandemic. METHODS: We used qualitative methods (in-depth interviews n=132, focus group discussions n=15) with purposively sampled neonatal health systems actors in Kenya, Malawi, Nigeria and Tanzania. Data were collected from September 2021 - August 2022. Topic guides were co-developed with key stakeholders and used to gain a detailed understanding of approaches to protect SSNC during the COVID-19 pandemic. Questions explored policy development, collaboration and investments, organisation of care, human resources, and technology and device innovations. Interviews were conducted by experienced qualitative researchers and data were collected until saturation was reached. Interviews were digitally recorded and transcribed verbatim. A common coding framework was developed, and data were coded via NVivo and analysed using a thematic framework approach. FINDINGS: We identified two pathways via which SSNC was strengthened. The first pathway, COVID-19 specific responses with secondary benefit to SSNC included: rapid policy development and adaptation, new and collaborative funding partnerships, improved oxygen systems, strengthened infection prevention and control practices. The second pathway, health system mitigation strategies during the pandemic, included: enhanced information systems, human resource adaptations, service delivery innovations, e.g., telemedicine, community engagement and more emphasis on planned preventive maintenance of devices. Chronic system weaknesses were also identified that limited the sustainability and institutionalisation of actions to protect SSNC. CONCLUSION: Innovations to protect SSNC in response to the COVID-19 pandemic should be maintained to support resilience and high-quality routine SSNC delivery. In particular, allocation of resources to sustain high quality and resilient care practices and address remaining gaps for SSNC is critical.


Asunto(s)
COVID-19 , Telemedicina , Recién Nacido , Humanos , COVID-19/epidemiología , COVID-19/prevención & control , Pandemias/prevención & control , Nigeria , Malaui
6.
BMC Pediatr ; 23(Suppl 2): 564, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37968603

RESUMEN

BACKGROUND: Medical devices are critical to providing high-quality, hospital-based newborn care, yet many of these devices are unavailable in low- and middle-income countries (LMIC) and are not designed to be suitable for these settings. Target Product Profiles (TPPs) are often utilised at an early stage in the medical device development process to enable user-defined performance characteristics for a given setting. TPPs can also be applied to assess the profile and match of existing devices for a given context. METHODS: We developed initial TPPs for 15 newborn product categories for LMIC settings. A Delphi-like process was used to develop the TPPs. Respondents completed an online survey where they scored their level of agreement with each of the proposed performance characteristics for each of the 15 devices. Characteristics with < 75% agreement between respondents were discussed and voted on using Mentimeter™ at an in-person consensus meeting. FINDINGS: The TPP online survey was sent to 180 people, of which 103 responded (57%). The majority of respondents were implementers/clinicians (51%, 53/103), with 50% (52/103) from LMIC. Across the 15 TPPs, 403 (60%) of the 668 performance characteristics did not achieve > 75% agreement. Areas of disagreement were voted on by 69 participants at an in-person consensus meeting, with consensus achieved for 648 (97%) performance characteristics. Only 20 (3%) performance characteristics did not achieve consensus, most (15/20) relating to quality management systems. UNICEF published the 15 TPPs in April 2020, accompanied by a report detailing the online survey results and consensus meeting discussion, which has been viewed 7,039 times (as of January 2023). CONCLUSIONS: These 15 TPPs can inform developers and enable implementers to select neonatal care products for LMIC. Over 2,400 medical devices and diagnostics meeting these TPPs have been installed in 65 hospitals in Nigeria, Tanzania, Kenya, and Malawi through the NEST360 Alliance. Twenty-three medical devices identified and qualified by NEST360 meet nearly all performance characteristics across 11 of the 15 TPPs. Eight of the 23 qualified medical devices are available in the UNICEF Supply Catalogue. Some developers have adjusted their technologies to meet these TPPs. There is potential to adapt the TPP process beyond newborn care.


Asunto(s)
Naciones Unidas , Recién Nacido , Humanos , Kenia , Malaui , Nigeria , Tanzanía
7.
BMC Pediatr ; 23(Suppl 2): 568, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37968606

RESUMEN

BACKGROUND: Thirty million small and sick newborns worldwide require inpatient care each year. Many receive antibiotics for clinically diagnosed infections without blood cultures, the current 'gold standard' for neonatal infection detection. Low neonatal blood culture use hampers appropriate antibiotic use, fuelling antimicrobial resistance (AMR) which threatens newborn survival. This study analysed the gap between blood culture use and antibiotic prescribing in hospitals implementing with Newborn Essential Solutions and Technologies (NEST360) in Kenya, Malawi, Nigeria, and Tanzania. METHODS: Inpatient data from every newborn admission record (July 2019-August 2022) were included to describe hospital-level blood culture use and antibiotic prescription. Health Facility Assessment data informed performance categorisation of hospitals into four tiers: (Tier 1) no laboratory, (Tier 2) laboratory but no microbiology, (Tier 3) neonatal blood culture use < 50% of newborns receiving antibiotics, and (Tier 4) neonatal blood culture use > 50%. RESULTS: A total of 144,146 newborn records from 61 hospitals were analysed. Mean hospital antibiotic prescription was 70% (range = 25-100%), with 6% mean blood culture use (range = 0-56%). Of the 10,575 blood cultures performed, only 24% (95%CI 23-25) had results, with 10% (10-11) positivity. Overall, 40% (24/61) of hospitals performed no blood cultures for newborns. No hospitals were categorised as Tier 1 because all had laboratories. Of Tier 2 hospitals, 87% (20/23) were District hospitals. Most hospitals could do blood cultures (38/61), yet the majority were categorised as Tier 3 (36/61). Only two hospitals performed > 50% blood cultures for newborns on antibiotics (Tier 4). CONCLUSIONS: The two Tier 4 hospitals, with higher use of blood cultures for newborns, underline potential for higher blood culture coverage in other similar hospitals. Understanding why these hospitals are positive outliers requires more research into local barriers and enablers to performing blood cultures. Tier 3 facilities are missing opportunities for infection detection, and quality improvement strategies in neonatal units could increase coverage rapidly. Tier 2 facilities could close coverage gaps, but further laboratory strengthening is required. Closing this culture gap is doable and a priority for advancing locally-driven antibiotic stewardship programmes, preventing AMR, and reducing infection-related newborn deaths.


Asunto(s)
Antibacterianos , Cultivo de Sangre , Recién Nacido , Humanos , Antibacterianos/uso terapéutico , Estudios Transversales , Kenia , Pacientes Internos , Malaui , Tanzanía , Nigeria , Hospitales
8.
BMC Pediatr ; 23(Suppl 2): 567, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37968588

RESUMEN

BACKGROUND: Every Newborn Action Plan (ENAP) coverage target 4 necessitates national scale-up of Level-2 Small and Sick Newborn Care (SSNC) (with Continuous Positive Airway Pressure (CPAP)) in 80% of districts by 2025. Routine neonatal inpatient data is important for improving quality of care, targeting equity gaps, and enabling data-driven decision-making at individual, district, and national-levels. Existing neonatal inpatient datasets vary in purpose, size, definitions, and collection processes. We describe the co-design and operationalisation of a core inpatient dataset for use to track outcomes and improve quality of care for small and sick newborns in high-mortality settings. METHODS: A three-step systematic framework was used to review, co-design, and operationalise this novel neonatal inpatient dataset in four countries (Malawi, Kenya, Tanzania, and Nigeria) implementing with the Newborn Essential Solutions and Technologies (NEST360) Alliance. Existing global and national datasets were identified, and variables were mapped according to categories. A priori considerations for variable inclusion were determined by clinicians and policymakers from the four African governments by facilitated group discussions. These included prioritising clinical care and newborn outcomes data, a parsimonious variable list, and electronic data entry. The tool was designed and refined by > 40 implementers and policymakers during a multi-stakeholder workshop and online interactions. RESULTS: Identified national and international datasets (n = 6) contained a median of 89 (IQR:61-154) variables, with many relating to research-specific initiatives. Maternal antenatal/intrapartum history was the largest variable category (21, 23.3%). The Neonatal Inpatient Dataset (NID) includes 60 core variables organised in six categories: (1) birth details/maternal history; (2) admission details/identifiers; (3) clinical complications/observations; (4) interventions/investigations; (5) discharge outcomes; and (6) diagnosis/cause-of-death. Categories were informed through the mapping process. The NID has been implemented at 69 neonatal units in four African countries and links to a facility-level quality improvement (QI) dashboard used in real-time by facility staff. CONCLUSION: The NEST360 NID is a novel, parsimonious tool for use in routine information systems to inform inpatient SSNC quality. Available on the NEST360/United Nations Children's Fund (UNICEF) Implementation Toolkit for SSNC, this adaptable tool enables facility and country-level comparisons to accelerate progress toward ENAP targets. Additional linked modules could include neonatal at-risk follow-up, retinopathy of prematurity, and Level-3 intensive care.


Asunto(s)
Países en Desarrollo , Pacientes Internos , Niño , Recién Nacido , Embarazo , Humanos , Femenino , Calidad de la Atención de Salud , Parto , Tanzanía
9.
BMC Med ; 20(1): 28, 2022 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-35081974

RESUMEN

BACKGROUND: Understanding the age patterns of disease is necessary to target interventions to maximise cost-effective impact. New malaria chemoprevention and vaccine initiatives target young children attending routine immunisation services. Here we explore the relationships between age and severity of malaria hospitalisation versus malaria transmission intensity. METHODS: Clinical data from 21 surveillance hospitals in East Africa were reviewed. Malaria admissions aged 1 month to 14 years from discrete administrative areas since 2006 were identified. Each site-time period was matched to a model estimated community-based age-corrected parasite prevalence to provide predictions of prevalence in childhood (PfPR2-10). Admission with all-cause malaria, severe malaria anaemia (SMA), respiratory distress (RD) and cerebral malaria (CM) were analysed as means and predicted probabilities from Bayesian generalised mixed models. RESULTS: 52,684 malaria admissions aged 1 month to 14 years were described at 21 hospitals from 49 site-time locations where PfPR2-10 varied from < 1 to 48.7%. Twelve site-time periods were described as low transmission (PfPR2-10 < 5%), five low-moderate transmission (PfPR2-10 5-9%), 20 moderate transmission (PfPR2-10 10-29%) and 12 high transmission (PfPR2-10 ≥ 30%). The majority of malaria admissions were below 5 years of age (69-85%) and rare among children aged 10-14 years (0.7-5.4%) across all transmission settings. The mean age of all-cause malaria hospitalisation was 49.5 months (95% CI 45.1, 55.4) under low transmission compared with 34.1 months (95% CI 30.4, 38.3) at high transmission, with similar trends for each severe malaria phenotype. CM presented among older children at a mean of 48.7 months compared with 39.0 months and 33.7 months for SMA and RD, respectively. In moderate and high transmission settings, 34% and 42% of the children were aged between 2 and 23 months and so within the age range targeted by chemoprevention or vaccines. CONCLUSIONS: Targeting chemoprevention or vaccination programmes to areas where community-based parasite prevalence is ≥10% is likely to match the age ranges covered by interventions (e.g. intermittent presumptive treatment in infancy to children aged 2-23 months and current vaccine age eligibility and duration of efficacy) and the age ranges of highest disease burden.


Asunto(s)
Malaria Cerebral , Malaria Falciparum , Adolescente , África Oriental/epidemiología , Teorema de Bayes , Niño , Preescolar , Hospitalización , Humanos , Lactante , Malaria Cerebral/epidemiología , Malaria Falciparum/epidemiología , Fenotipo
10.
BMC Pregnancy Childbirth ; 21(Suppl 1): 232, 2021 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-33765959

RESUMEN

BACKGROUND: Globally an estimated 20.5 million liveborn babies are low birthweight (LBW) each year, weighing less than 2500 g. LBW babies have increased risk of mortality even beyond the neonatal period, with an ongoing risk of stunting and non-communicable diseases. LBW is a priority global health indicator. Now almost 80% of births are in facilities, yet birthweight data are lacking in most high-mortality burden countries and are of poor quality, notably with heaping especially on values ending in 00. We aimed to undertake qualitative research in a regional hospital in Dar es Salaam, Tanzania, observing birthweight weighing scales, exploring barriers and enablers to weighing at birth as well as perceived value of birthweight data to health workers, women and stakeholders. METHODS: Observations were undertaken on type of birthweight scale availability in hospital wards. In-depth semi-structured interviews (n = 21) were conducted with three groups: women in postnatal and kangaroo mother care wards, health workers involved in birthweight measurement and recording, and stakeholders involved in data aggregation in Temeke Hospital, Tanzania, a site in the EN-BIRTH study. An inductive thematic analysis was undertaken of translated interview transcripts. RESULTS: Of five wards that were expected to have scales, three had functional scales, and only one of the functional scales was digital. The labour ward weighed the most newborns using an analogue scale that was not consistently zeroed. Hospital birthweight data were aggregated monthly for reporting into the health management information system. Birthweight measurement was highly valued by all respondents, notably families and healthcare workers, and local use of data was considered an enabler. Perceived barriers to high quality birthweight data included: gaps in availability of precise weighing devices, adequate health workers and imprecise measurement practices. CONCLUSION: Birthweight measurement is valued by families and health workers. There are opportunities to close the gap between the percentage of babies born in facilities and the percentage accurately weighed at birth by providing accurate scales, improving skills training and increasing local use of data. More accurate birthweight data are vitally important for all babies and specifically to track progress in preventing and improving immediate and long-term care for low birthweight children.


Asunto(s)
Peso al Nacer , Recién Nacido de Bajo Peso , Atención Perinatal/organización & administración , Pesos y Medidas/instrumentación , Adulto , Exactitud de los Datos , Femenino , Edad Gestacional , Sistemas de Información en Salud/estadística & datos numéricos , Conocimientos, Actitudes y Práctica en Salud , Hospitales/estadística & datos numéricos , Humanos , Recién Nacido , Persona de Mediana Edad , Embarazo , Brechas de la Práctica Profesional/estadística & datos numéricos , Investigación Cualitativa , Tanzanía , Factores de Tiempo , Adulto Joven
11.
BMC Pregnancy Childbirth ; 21(Suppl 1): 236, 2021 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-33765957

RESUMEN

BACKGROUND: Birth registration marks a child's right to identity and is the first step to establishing citizenship and access to services. At the population level, birth registration data can inform effective programming and planning. In Tanzania, almost two-thirds of births are in health facilities, yet only 26% of children under 5 years have their births registered. Our mixed-methods research explores the gap between hospital birth and birth registration in Dar es Salaam, Tanzania. METHODS: The study was conducted in the two Tanzanian hospital sites of the Every Newborn-Birth Indicators Research Tracking in Hospitals (EN-BIRTH) multi-country study (July 2017-2018). We described the business processes for birth notification and registration and collected quantitative data from women's exit surveys after giving birth (n = 8038). We conducted in-depth interviews (n = 21) to identify barriers and enablers to birth registration among four groups of participants: women who recently gave birth, women waiting for a birth certificate at Temeke Hospital, hospital employees, and stakeholders involved in the national birth registration process. We synthesized findings to identify opportunities to improve birth registration. RESULTS: Standard national birth registration procedures were followed at Muhimbili Hospital; families received birth notification and were advised to obtain a birth certificate from the Registration, Insolvency, and Trusteeship Agency (RITA) after 2 months, for a fee. A pilot programme to improve birth registration coverage included Temeke Hospital; hand-written birth certificates were issued free of charge on a return hospital visit after 42 days. Among 2500 women exit-surveyed at Muhimbili Hospital, 96.3% reported receiving a birth notification form and nearly half misunderstood this to be a birth certificate. Of the 5538 women interviewed at Temeke Hospital, 33.0% reported receiving any documentation confirming the birth of their child. In-depth interview respondents perceived birth registration to be important but considered both the standard and pilot processes in Tanzania complex, burdensome and costly to both families and health workers. CONCLUSION: Birth registration coverage in Tanzania could be improved by further streamlining between health facilities, where most babies are born, and the civil registry. Families and health workers need support to navigate processes to register every child.


Asunto(s)
Certificado de Nacimiento , Hospitales/estadística & datos numéricos , Sistema de Registros/estadística & datos numéricos , Adolescente , Adulto , Femenino , Humanos , Recién Nacido , Masculino , Edad Materna , Embarazo , Encuestas y Cuestionarios , Tanzanía , Adulto Joven
12.
BMC Pregnancy Childbirth ; 21(Suppl 1): 240, 2021 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-33765936

RESUMEN

BACKGROUND: Accurate birthweight is critical to inform clinical care at the individual level and tracking progress towards national/global targets at the population level. Low birthweight (LBW) < 2500 g affects over 20.5 million newborns annually. However, data are lacking and may be affected by heaping. This paper evaluates birthweight measurement within the Every Newborn Birth Indicators Research Tracking in Hospitals (EN-BIRTH) study. METHODS: The EN-BIRTH study took place in five hospitals in Bangladesh, Nepal and Tanzania (2017-2018). Clinical observers collected time-stamped data (gold standard) for weighing at birth. We compared accuracy for two data sources: routine hospital registers and women's report at exit interview survey. We calculated absolute differences and individual-level validation metrics. We analysed birthweight coverage and quality gaps including timing and heaping. Qualitative data explored barriers and enablers for routine register data recording. RESULTS: Among 23,471 observed births, 98.8% were weighed. Exit interview survey-reported weighing coverage was 94.3% (90.2-97.3%), sensitivity 95.0% (91.3-97.8%). Register-reported coverage was 96.6% (93.2-98.9%), sensitivity 97.1% (94.3-99%). Routine registers were complete (> 98% for four hospitals) and legible > 99.9%. Weighing of stillbirths varied by hospital, ranging from 12.5-89.0%. Observed LBW rate was 15.6%; survey-reported rate 14.3% (8.9-20.9%), sensitivity 82.9% (75.1-89.4%), specificity 96.1% (93.5-98.5%); register-recorded rate 14.9%, sensitivity 90.8% (85.9-94.8%), specificity 98.5% (98-99.0%). In surveys, "don't know" responses for birthweight measured were 4.7%, and 2.9% for knowing the actual weight. 95.9% of observed babies were weighed within 1 h of birth, only 14.7% with a digital scale. Weight heaping indices were around two-fold lower using digital scales compared to analogue. Observed heaping was almost 5% higher for births during the night than day. Survey-report further increased observed birthweight heaping, especially for LBW babies. Enablers to register birthweight measurement in qualitative interviews included digital scale availability and adequate staffing. CONCLUSIONS: Hospital registers captured birthweight and LBW prevalence more accurately than women's survey report. Even in large hospitals, digital scales were not always available and stillborn babies not always weighed. Birthweight data are being captured in hospitals and investment is required to further improve data quality, researching of data flow in routine systems and use of data at every level.


Asunto(s)
Peso al Nacer , Exactitud de los Datos , Recién Nacido de Bajo Peso , Atención Perinatal/organización & administración , Indicadores de Calidad de la Atención de Salud/estadística & datos numéricos , Adulto , Bangladesh/epidemiología , Femenino , Hospitales/estadística & datos numéricos , Humanos , Recién Nacido , Persona de Mediana Edad , Nepal/epidemiología , Embarazo , Prevalencia , Investigación Cualitativa , Sistema de Registros/estadística & datos numéricos , Sensibilidad y Especificidad , Mortinato , Encuestas y Cuestionarios/estadística & datos numéricos , Tanzanía/epidemiología , Factores de Tiempo , Adulto Joven
13.
BMC Pregnancy Childbirth ; 21(Suppl 1): 239, 2021 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-33765947

RESUMEN

BACKGROUND: Umbilical cord hygiene prevents sepsis, a leading cause of neonatal mortality. The World Health Organization recommends 7.1% chlorhexidine digluconate (CHX) application to the umbilicus after home birth in high mortality contexts. In Bangladesh and Nepal, national policies recommend CHX use for all facility births. Population-based household surveys include optional questions on CHX use, but indicator validation studies are lacking. The Every Newborn Birth Indicators Research Tracking in Hospitals (EN-BIRTH) was an observational study assessing measurement validity for maternal and newborn indicators. This paper reports results regarding CHX. METHODS: The EN-BIRTH study (July 2017-July 2018) included three public hospitals in Bangladesh and Nepal where CHX cord application is routine. Clinical-observers collected tablet-based, time-stamped data regarding cord care during admission to labour and delivery wards as the gold standard to assess accuracy of women's report at exit survey, and of routine-register data. We calculated validity ratios and individual-level validation metrics; analysed coverage, quality and measurement gaps. We conducted qualitative interviews to assess barriers and enablers to routine register-recording. RESULTS: Umbilical cord care was observed for 12,379 live births. Observer-assessed CHX coverage was very high at 89.3-99.4% in all 3 hospitals, although slightly lower after caesarean births in Azimpur (86.8%), Bangladesh. Exit survey-reported coverage (0.4-45.9%) underestimated the observed coverage with substantial "don't know" responses (55.5-79.4%). Survey-reported validity ratios were all poor (0.01 to 0.38). Register-recorded coverage in the specific column in Bangladesh was underestimated by 0.2% in Kushtia but overestimated by 9.0% in Azimpur. Register-recorded validity ratios were good (0.9 to 1.1) in Bangladesh, and poor (0.8) in Nepal. The non-specific register column in Pokhara, Nepal substantially underestimated coverage (20.7%). CONCLUSIONS: Exit survey-report highly underestimated observed CHX coverage in all three hospitals. Routine register-recorded coverage was closer to observer-assessed coverage than survey reports in all hospitals, including for caesarean births, and was more accurately captured in hospitals with a specific register column. Inclusion of CHX cord care into registers, and tallied into health management information system platforms, is justified in countries with national policies for facility-based use, but requires implementation research to assess register design and data flow within health information systems.


Asunto(s)
Antiinfecciosos Locales/administración & dosificación , Clorhexidina/análogos & derivados , Exactitud de los Datos , Sepsis Neonatal/prevención & control , Cordón Umbilical/efectos de los fármacos , Adulto , Bangladesh , Clorhexidina/administración & dosificación , Femenino , Humanos , Recién Nacido , Sepsis Neonatal/microbiología , Nepal , Embarazo , Sistema de Registros/estadística & datos numéricos , Encuestas y Cuestionarios/estadística & datos numéricos , Cordón Umbilical/microbiología , Cordón Umbilical/cirugía , Adulto Joven
14.
BMC Pregnancy Childbirth ; 21(Suppl 1): 234, 2021 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-33765951

RESUMEN

BACKGROUND: Observation of care at birth is challenging with multiple, rapid and potentially concurrent events occurring for mother, newborn and placenta. Design of electronic data (E-data) collection needs to account for these challenges. The Every Newborn Birth Indicators Research Tracking in Hospitals (EN-BIRTH) was an observational study to assess measurement of indicators for priority maternal and newborn interventions and took place in five hospitals in Bangladesh, Nepal and Tanzania (July 2017-July 2018). E-data tools were required to capture individually-linked, timed observation of care, data extraction from hospital register-records or case-notes, and exit-survey data from women. METHODS: To evaluate this process for EN-BIRTH, we employed a framework organised around five steps for E-data design, data collection and implementation. Using this framework, a mixed methods evaluation synthesised evidence from study documentation, standard operating procedures, stakeholder meetings and design workshops. We undertook focus group discussions with EN-BIRTH researchers to explore experiences from the three different country teams (November-December 2019). Results were organised according to the five a priori steps. RESULTS: In accordance with the five-step framework, we found: 1) Selection of data collection approach and software: user-centred design principles were applied to meet the challenges for observation of rapid, concurrent events around the time of birth with time-stamping. 2) Design of data collection tools and programming: required extensive pilot testing of tools to be user-focused and to include in-built error messages and data quality alerts. 3) Recruitment and training of data collectors: standardised with an interactive training package including pre/post-course assessment. 4) Data collection, quality assurance, and management: real-time quality assessments with a tracking dashboard and double observation/data extraction for a 5% case subset, were incorporated as part of quality assurance. Internet-based synchronisation during data collection posed intermittent challenges. 5) Data management, cleaning and analysis: E-data collection was perceived to improve data quality and reduce time cleaning. CONCLUSIONS: The E-Data system, custom-built for EN-BIRTH, was valued by the site teams, particularly for time-stamped clinical observation of complex multiple simultaneous events at birth, without which the study objectives could not have been met. However before selection of a custom-built E-data tool, the development time, higher training and IT support needs, and connectivity challenges need to be considered against the proposed study or programme's purpose, and currently available E-data tool options.


Asunto(s)
Registros Electrónicos de Salud/organización & administración , Sistemas de Información en Hospital/organización & administración , Hospitales/estadística & datos numéricos , Atención Perinatal/organización & administración , Bangladesh , Exactitud de los Datos , Registros Electrónicos de Salud/estadística & datos numéricos , Femenino , Grupos Focales , Sistemas de Información en Hospital/estadística & datos numéricos , Humanos , Recién Nacido , Nepal , Atención Perinatal/estadística & datos numéricos , Embarazo , Programas Informáticos , Encuestas y Cuestionarios , Tanzanía
15.
BMC Pregnancy Childbirth ; 21(Suppl 1): 229, 2021 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-33765948

RESUMEN

BACKGROUND: An estimated 30 million neonates require inpatient care annually, many with life-threatening infections. Appropriate antibiotic management is crucial, yet there is no routine measurement of coverage. The Every Newborn Birth Indicators Research Tracking in Hospitals (EN-BIRTH) study aimed to validate maternal and newborn indicators to inform measurement of coverage and quality of care. This paper reports validation of reported antibiotic coverage by exit survey of mothers for hospitalized newborns with clinically-defined infections, including sepsis, meningitis, and pneumonia. METHODS: EN-BIRTH study was conducted in five hospitals in Bangladesh, Nepal, and Tanzania (July 2017-July 2018). Neonates were included based on case definitions to focus on term/near-term, clinically-defined infection syndromes (sepsis, meningitis, and pneumonia), excluding major congenital abnormalities. Clinical management was abstracted from hospital inpatient case notes (verification) which was considered as the gold standard against which to validate accuracy of women's report. Exit surveys were conducted using questions similar to The Demographic and Health Surveys (DHS) approach for coverage of childhood pneumonia treatment. We compared survey-report to case note verified, pooled across the five sites using random effects meta-analysis. RESULTS: A total of 1015 inpatient neonates admitted in the five hospitals met inclusion criteria with clinically-defined infection syndromes. According to case note verification, 96.7% received an injectable antibiotic, although only 14.5% of them received the recommended course of at least 7 days. Among women surveyed (n = 910), 98.8% (95% CI: 97.8-99.5%) correctly reported their baby was admitted to a neonatal ward. Only 47.1% (30.1-64.5%) reported their baby's diagnosis in terms of sepsis, meningitis, or pneumonia. Around three-quarters of women reported their baby received an injection whilst in hospital, but 12.3% reported the correct antibiotic name. Only 10.6% of the babies had a blood culture and less than 1% had a lumbar puncture. CONCLUSIONS: Women's report during exit survey consistently underestimated the denominator (reporting the baby had an infection), and even more so the numerator (reporting known injectable antibiotics). Admission to the neonatal ward was accurately reported and may have potential as a contact point indicator for use in household surveys, similar to institutional births. Strengthening capacity and use of laboratory diagnostics including blood culture are essential to promote appropriate use of antibiotics. To track quality of neonatal infection management, we recommend using inpatient records to measure specifics, requiring more research on standardised inpatient records.


Asunto(s)
Antibacterianos/uso terapéutico , Cuidado del Lactante/estadística & datos numéricos , Meningitis Bacterianas/tratamiento farmacológico , Sepsis Neonatal/tratamiento farmacológico , Neumonía Bacteriana/tratamiento farmacológico , Bangladesh/epidemiología , Utilización de Medicamentos/estadística & datos numéricos , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Cuidado del Lactante/organización & administración , Recién Nacido , Masculino , Meningitis Bacterianas/epidemiología , Sepsis Neonatal/epidemiología , Nepal/epidemiología , Neumonía Bacteriana/epidemiología , Embarazo , Indicadores de Calidad de la Atención de Salud/estadística & datos numéricos , Encuestas y Cuestionarios/estadística & datos numéricos , Tanzanía/epidemiología , Adulto Joven
16.
BMC Pregnancy Childbirth ; 21(Suppl 1): 231, 2021 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-33765950

RESUMEN

BACKGROUND: Kangaroo mother care (KMC) reduces mortality among stable neonates ≤2000 g. Lack of data tracking coverage and quality of KMC in both surveys and routine information systems impedes scale-up. This paper evaluates KMC measurement as part of the Every Newborn Birth Indicators Research Tracking in Hospitals (EN-BIRTH) study. METHODS: The EN-BIRTH observational mixed-methods study was conducted in five hospitals in Bangladesh, Nepal and Tanzania from 2017 to 2018. Clinical observers collected time-stamped data as gold standard for mother-baby pairs in KMC wards/corners. To assess accuracy, we compared routine register-recorded and women's exit survey-reported coverage to observed data, using different recommended denominator options (≤2000 g and ≤ 2499 g). We analysed gaps in quality of provision and experience of KMC. In the Tanzanian hospitals, we assessed daily skin-to-skin duration/dose and feeding frequency. Qualitative data were collected from health workers and data collectors regarding barriers and enablers to routine register design, filling and use. RESULTS: Among 840 mother-baby pairs, compared to observed 100% coverage, both exit-survey reported (99.9%) and register-recorded coverage (92.9%) were highly valid measures with high sensitivity. KMC specific registers outperformed general registers. Enablers to register recording included perceptions of data usefulness, while barriers included duplication of data elements and overburdened health workers. Gaps in KMC quality were identified for position components including wearing a hat. In Temeke Tanzania, 10.6% of babies received daily KMC skin-to-skin duration/dose of ≥20 h and a further 75.3% received 12-19 h. Regular feeding ≥8 times/day was observed for 36.5% babies in Temeke Tanzania and 14.6% in Muhimbili Tanzania. Cup-feeding was the predominant assisted feeding method. Family support during admission was variable, grandmothers co-provided KMC more often in Bangladesh. No facility arrangements for other family members were reported by 45% of women at exit survey. CONCLUSIONS: Routine hospital KMC register data have potential to track coverage from hospital KMC wards/corners. Women accurately reported KMC at exit survey and evaluation for population-based surveys could be considered. Measurement of content, quality and experience of KMC need consensus on definitions. Prioritising further KMC measurement research is important so that high quality data can be used to accelerate scale-up of high impact care for the most vulnerable.


Asunto(s)
Recién Nacido de Bajo Peso , Método Madre-Canguro/estadística & datos numéricos , Mortalidad Perinatal , Sistema de Registros/estadística & datos numéricos , Adolescente , Adulto , Bangladesh/epidemiología , Exactitud de los Datos , Femenino , Edad Gestacional , Hospitalización/estadística & datos numéricos , Hospitales/estadística & datos numéricos , Humanos , Lactante , Recién Nacido , Unidades de Cuidado Intensivo Neonatal/estadística & datos numéricos , Método Madre-Canguro/organización & administración , Nepal/epidemiología , Embarazo , Sensibilidad y Especificidad , Encuestas y Cuestionarios/estadística & datos numéricos , Tanzanía/epidemiología , Factores de Tiempo , Adulto Joven
17.
BMC Health Serv Res ; 20(1): 737, 2020 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-32787852

RESUMEN

BACKGROUND: Countries with the highest burden of maternal and newborn deaths and stillbirths often have little information on these deaths. Since over 81% of births worldwide now occur in facilities, using routine facility data could reduce this data gap. We assessed the availability, quality, and utility of routine labour and delivery ward register data in five hospitals in Bangladesh, Nepal, and Tanzania. This paper forms the baseline register assessment for the Every Newborn-Birth Indicators Research Tracking in Hospitals (EN-BIRTH) study. METHODS: We extracted 21 data elements from routine hospital labour ward registers, useful to calculate selected maternal and newborn health (MNH) indicators. The study sites were five public hospitals during a one-year period (2016-17). We measured 1) availability: completeness of data elements by register design, 2) data quality: implausibility, internal consistency, and heaping of birthweight and explored 3) utility by calculating selected MNH indicators using the available data. RESULTS: Data were extracted for 20,075 births. Register design was different between the five hospitals with 10-17 of the 21 selected MNH data elements available. More data were available for health outcomes than interventions. Nearly all available data elements were > 95% complete in four of the five hospitals and implausible values were rare. Data elements captured in specific columns were 85.2% highly complete compared to 25.0% captured in non-specific columns. Birthweight data were less complete for stillbirths than live births at two hospitals, and significant heaping was found in all sites, especially at 2500g and 3000g. All five hospitals recorded count data required to calculate impact indicators including; stillbirth rate, low birthweight rate, Caesarean section rate, and mortality rates. CONCLUSIONS: Data needed to calculate MNH indicators are mostly available and highly complete in EN-BIRTH study hospital routine labour ward registers in Bangladesh, Nepal and Tanzania. Register designs need to include interventions for coverage measurement. There is potential to improve data quality if Health Management Information Systems utilization with feedback loops can be strengthened. Routine health facility data could contribute to reduce the coverage and impact data gap around the time of birth.


Asunto(s)
Exactitud de los Datos , Salas de Parto , Sistema de Registros/normas , Bangladesh , Femenino , Humanos , Recién Nacido , Nepal , Embarazo , Tanzanía
18.
N Engl J Med ; 367(24): 2284-95, 2012 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-23136909

RESUMEN

BACKGROUND: The candidate malaria vaccine RTS,S/AS01 reduced episodes of both clinical and severe malaria in children 5 to 17 months of age by approximately 50% in an ongoing phase 3 trial. We studied infants 6 to 12 weeks of age recruited for the same trial. METHODS: We administered RTS,S/AS01 or a comparator vaccine to 6537 infants who were 6 to 12 weeks of age at the time of the first vaccination in conjunction with Expanded Program on Immunization (EPI) vaccines in a three-dose monthly schedule. Vaccine efficacy against the first or only episode of clinical malaria during the 12 months after vaccination, a coprimary end point, was analyzed with the use of Cox regression. Vaccine efficacy against all malaria episodes, vaccine efficacy against severe malaria, safety, and immunogenicity were also assessed. RESULTS: The incidence of the first or only episode of clinical malaria in the intention-to-treat population during the 14 months after the first dose of vaccine was 0.31 per person-year in the RTS,S/AS01 group and 0.40 per person-year in the control group, for a vaccine efficacy of 30.1% (95% confidence interval [CI], 23.6 to 36.1). Vaccine efficacy in the per-protocol population was 31.3% (97.5% CI, 23.6 to 38.3). Vaccine efficacy against severe malaria was 26.0% (95% CI, -7.4 to 48.6) in the intention-to-treat population and 36.6% (95% CI, 4.6 to 57.7) in the per-protocol population. Serious adverse events occurred with a similar frequency in the two study groups. One month after administration of the third dose of RTS,S/AS01, 99.7% of children were positive for anti-circumsporozoite antibodies, with a geometric mean titer of 209 EU per milliliter (95% CI, 197 to 222). CONCLUSIONS: The RTS,S/AS01 vaccine coadministered with EPI vaccines provided modest protection against both clinical and severe malaria in young infants. (Funded by GlaxoSmithKline Biologicals and the PATH Malaria Vaccine Initiative; RTS,S ClinicalTrials.gov number, NCT00866619.).


Asunto(s)
Vacunas contra la Malaria , Malaria Falciparum/prevención & control , Vacunas Sintéticas , África , Femenino , Humanos , Esquemas de Inmunización , Incidencia , Lactante , Análisis de Intención de Tratar , Vacunas contra la Malaria/efectos adversos , Vacunas contra la Malaria/inmunología , Malaria Falciparum/epidemiología , Masculino , Plasmodium falciparum/inmunología , Modelos de Riesgos Proporcionales , Resultado del Tratamiento , Vacunas Sintéticas/efectos adversos , Vacunas Sintéticas/inmunología
19.
Malar J ; 14: 72, 2015 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-25885325

RESUMEN

BACKGROUND: The malaria vaccine RTS,S induces antibodies against the Plasmodium falciparum circumsporozoite protein (CSP) and the concentration of Immunoglobulin G (IgG) against the repeat region of CSP following vaccination is associated with protection from P. falciparum malaria. So far, only the quantity of anti-CSP IgG has been measured and used to predict vaccination success, although quality (measured as avidity) of the antigen-antibody interaction shall be important since only a few sporozoites circulate for a short time after an infectious mosquito bite, likely requiring fast and strong binding. METHODS: Quantity and avidity of anti-CSP IgG in African infants who received RTS,S/AS01E in a 0-1-2-month or a 0-1-7-month schedule in a phase 2 clinical trial were measured by enzyme-linked immunosorbent assay. Antibody avidity was defined as the proportion of IgG able to bind in the presence of a chaotropic agent (avidity index). The effect of CSP-specific IgG concentration and avidity on protective efficacy was modelled using Cox proportional hazards. RESULTS: After the third dose, quantity and avidity were similar between the two vaccination schedules. IgG avidity after the last vaccine injection was not associated with protection, whereas the change in avidity following second and third RTS,S/AS01E injection was associated with a 54% risk reduction of getting malaria (hazard ratio: 0.46; 95% confidence interval (CI): 0.22-0.99) in those participants with a change in avidity above the median. The change in anti-CSP IgG concentration following second and third injection was associated with a 77% risk reduction of getting malaria (hazard ratio: 0.23, 95% CI: 0.11-0.51). CONCLUSIONS: Change in IgG response between vaccine doses merits further evaluation as a surrogate marker for RTS,S efficacy. TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT00436007 .


Asunto(s)
Esquemas de Inmunización , Vacunas contra la Malaria/inmunología , Malaria Falciparum/inmunología , Proteínas Protozoarias/inmunología , Afinidad de Anticuerpos/inmunología , Ensayo de Inmunoadsorción Enzimática , Humanos , Estimación de Kaplan-Meier , Malaria Falciparum/prevención & control , Plasmodium falciparum/inmunología
20.
N Engl J Med ; 365(20): 1863-75, 2011 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-22007715

RESUMEN

BACKGROUND: An ongoing phase 3 study of the efficacy, safety, and immunogenicity of candidate malaria vaccine RTS,S/AS01 is being conducted in seven African countries. METHODS: From March 2009 through January 2011, we enrolled 15,460 children in two age categories--6 to 12 weeks of age and 5 to 17 months of age--for vaccination with either RTS,S/AS01 or a non-malaria comparator vaccine. The primary end point of the analysis was vaccine efficacy against clinical malaria during the 12 months after vaccination in the first 6000 children 5 to 17 months of age at enrollment who received all three doses of vaccine according to protocol. After 250 children had an episode of severe malaria, we evaluated vaccine efficacy against severe malaria in both age categories. RESULTS: In the 14 months after the first dose of vaccine, the incidence of first episodes of clinical malaria in the first 6000 children in the older age category was 0.32 episodes per person-year in the RTS,S/AS01 group and 0.55 episodes per person-year in the control group, for an efficacy of 50.4% (95% confidence interval [CI], 45.8 to 54.6) in the intention-to-treat population and 55.8% (97.5% CI, 50.6 to 60.4) in the per-protocol population. Vaccine efficacy against severe malaria was 45.1% (95% CI, 23.8 to 60.5) in the intention-to-treat population and 47.3% (95% CI, 22.4 to 64.2) in the per-protocol population. Vaccine efficacy against severe malaria in the combined age categories was 34.8% (95% CI, 16.2 to 49.2) in the per-protocol population during an average follow-up of 11 months. Serious adverse events occurred with a similar frequency in the two study groups. Among children in the older age category, the rate of generalized convulsive seizures after RTS,S/AS01 vaccination was 1.04 per 1000 doses (95% CI, 0.62 to 1.64). CONCLUSIONS: The RTS,S/AS01 vaccine provided protection against both clinical and severe malaria in African children. (Funded by GlaxoSmithKline Biologicals and the PATH Malaria Vaccine Initiative; RTS,S ClinicalTrials.gov number, NCT00866619 .).


Asunto(s)
Vacunas contra la Malaria , Malaria Falciparum/prevención & control , Plasmodium falciparum , África , Factores de Edad , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Lactante , Análisis de Intención de Tratar , Vacunas contra la Malaria/efectos adversos , Vacunas contra la Malaria/inmunología , Malaria Falciparum/epidemiología , Malaria Falciparum/parasitología , Masculino , Meningitis/epidemiología , Meningitis/etiología , Carga de Parásitos , Plasmodium falciparum/inmunología , Plasmodium falciparum/aislamiento & purificación , Convulsiones/epidemiología , Convulsiones/etiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA