Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circ J ; 85(8): 1314-1320, 2021 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-33883380

RESUMEN

BACKGROUND: SATAKE HotBalloon®catheter (HBC) is a radiofrequency balloon catheter for the treatment of atrial fibrillation (AF), and was approved for use in Japan to treat drug-resistant paroxysmal AF in 2015. Post-marketing surveillance study was conducted by Toray Industries, Inc. to evaluate the efficacy and safety of HBC treatment in patients with paroxysmal AF in a real-world setting. This study is the first nation-wide survey of HBC treatment for paroxysmal AF in clinical practice in Japan.Methods and Results:This was a single-arm, multicenter observational study with an observation period of 48 weeks after ablation. Pulmonary vein isolation and AF non-recurrence rates were evaluated and adverse events (AEs) were observed at 46 sites in Japan. An AF event was defined as recurrence of AF or re-ablation from 12 to 48 weeks after ablation. The success rate of pulmonary vein isolation was 99.0% (486/491) for patients with AF. The cumulative AF non-recurrence rate was 94.1% at 24 weeks and 87.8% at 48 weeks. AEs were found to occur 21.5% (114/530), and ablation-related AEs were found to occur 2.6% (14/530) during the study period, with the most common being pericardial effusion (0.8%, 4/530). CONCLUSIONS: This study demonstrates the efficacy and safety of HBC ablation in Japanese patients with recurrent symptomatic paroxysmal AF refractory to antiarrhythmic therapy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Catéteres , Humanos , Vigilancia de Productos Comercializados , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 27(8): 897-904, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27120698

RESUMEN

INTRODUCTION: There are some cases with frequent luminal esophageal temperature (LET) rises despite titrating the radiofrequency energy while creating a linear lesion for the Box isolation of atrial fibrillation (AF). Little is known about the feasibility of redesigning the ablation lines for a modified Box isolation strategy to prevent fatal esophageal injury in those cases. METHODS AND RESULTS: Two hundred and seventeen patients who underwent a Box isolation of non-paroxysmal AF were evaluated. We divided them into 2 groups, patients in whom a box lesion set of the entire posterior left atrium had been achieved (complete Box isolation [CBI]; n = 157) and those in whom 2 additional peri-esophageal vertical lines were created at both the right and left ends of the esophagus, and those areas were left with an incomplete isolation when frequent rapid LET rises above 39.0 °C were observed while creating the floor line (partial Box isolation [PBI]; n = 60). During 20.1 ± 13.9 months of follow-up, the arrhythmia-free rates were 54.1% in the CBI group versus 48.3% in the PBI group (P = 0.62). In the second session, a complete Box isolation was highly achieved even in the PBI group (94.3% vs. 83.3%, respectively; P = 0.17) and after 2 procedures, the arrhythmia-free rates increased to 75.2% vs. 68.3%, respectively (P = 0.34). There was no symptomatic esophageal injury in the PBI group. CONCLUSION: In the case of frequent LET rises while creating the linear lesions for the Box isolation strategy for non-paroxysmal AF, shifting to the PBI strategy was feasible.


Asunto(s)
Fibrilación Atrial/cirugía , Regulación de la Temperatura Corporal , Ablación por Catéter/métodos , Esófago/cirugía , Atrios Cardíacos/cirugía , Monitoreo Intraoperatorio/métodos , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Técnicas Electrofisiológicas Cardíacas , Esófago/fisiopatología , Estudios de Factibilidad , Femenino , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/instrumentación , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Termómetros , Factores de Tiempo , Resultado del Tratamiento
3.
J Cardiovasc Electrophysiol ; 26(12): 1298-306, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26331460

RESUMEN

INTRODUCTION: Isolation of pulmonary veins (PVs) and the posterior left atrium (LA) can be safely performed by radiofrequency hot balloon (RHB)-based box isolation. However, data on long-term effects for the treatment of atrial fibrillation (AF) by the use of this method remain limited. METHODS AND RESULTS: We treated 238 patients with paroxysmal AF (194 male; age. 62.6 ± 9.4 years) by RHB ablation. During 6.2-year (75 months) follow-up, 154 (64.7%) patients were free from atrial tachyarrhythmias (ATAs) without antiarrhythmic-drugs (AADs). We performed re-ablation in 69 of 84 patients with ATA recurrence (average 1.3 ± 0.6; median 1, total 91 procedures) using a 3D-mapping system and a conventional catheter. The sites of reconnection were observed at the PV in 61 of 69 (88.4%) patients and at the posterior LA in 58 of 69 (84.1%) patients. Finally, during mean follow-up of 4.6 ± 1.6 years, no-ATA episodes were detected in 201 (84.5%) patients without AADs. Independent predictors of ATA recurrence following a single procedure were heart failure with preserved ejection fraction (HR: 2.67, 95%CI: 1.40-5.10, P = 0.003) and low estimated glomerular filtration rate (HR: 1.81, 95%CI: 1.11-2.93, P = 0.03; cut-off of 62.0 mL/min/1.73 m(2)). During the follow-up period, there were 4 (1.7%) patients with PV stenosis (>70% reduction in PV diameter); however, none of these cases required intervention. Phrenic nerve palsy was detected in 8 patients (3.4%), but resolved during 3 months in all cases. CONCLUSION: RHB ablation can be effective during a long-term follow-up for patients with paroxysmal AF. Safety outcomes were within an acceptable range.


Asunto(s)
Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/fisiopatología , Función del Atrio Izquierdo , Ablación por Catéter/efectos adversos , Electrocardiografía , Femenino , Estudios de Seguimiento , Tasa de Filtración Glomerular , Insuficiencia Cardíaca/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Nervio Frénico , Estenosis de la Válvula Pulmonar/etiología , Recurrencia , Volumen Sistólico , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 25(7): 686-92, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24576252

RESUMEN

BACKGROUND: Little is known about luminal esophageal temperature (LET) monitoring during catheter ablation for atrial fibrillation (AF) using the radiofrequency hot balloon (RHB) technology. OBJECTIVE: The aim of this study is to investigate the impact of the use of a unique esophageal cooling method during RHB ablation. METHODS AND RESULTS: In this observational study, 318 consecutive patients (231 men; mean age, 63 ± 9 years) with symptomatic, drug-refractory, paroxysmal (n = 183) or persistent (n = 135) AF underwent RHB ablation with LET monitoring followed by a postprocedural, nonsymptom-driven esophageal endoscopy within 3 days of the ablation procedure. The patients have been divided into 3 groups. The first 22 patients treated are in Group A (n = 22) and had only LET monitoring without cooling of the esophagus. In Groups B (n = 128) and C (n = 168), patients had LET monitoring with cooling of the esophagus when the LET exceeded 43 °C and 39 °C, by infusion of cooled saline mixed with Gastrographin or Iopamidol, respectively. Group A had a higher risk of esophageal ulceration among the 3 groups (P < 0.0001). Saline infusion cooling initiated when the LET exceeded 43 °C (Group B) was not as safe as saline infusion cooling initiated when the LET exceeded 39 °C (Group C), demonstrated by the Group C minimum ulceration score and LET measurements while ablating the left superior pulmonary vein (LSPV) and left inferior pulmonary vein (LIPV) (P < 0.0001). CONCLUSION: Cooling the esophagus by a mix of Iopamidol and saline infusion when the LET exceeds 39 °C during RHB ablation may decrease the incidence and severity of esophageal thermal injury.


Asunto(s)
Fibrilación Atrial/cirugía , Quemaduras/prevención & control , Cateterismo Cardíaco , Catéteres Cardíacos , Ablación por Catéter , Esófago/lesiones , Irrigación Terapéutica , Úlcera/prevención & control , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Quemaduras/diagnóstico , Quemaduras/epidemiología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Diseño de Equipo , Esofagoscopía , Esófago/diagnóstico por imagen , Esófago/patología , Femenino , Humanos , Yopamidol/administración & dosificación , Japón/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Radiografía , Índice de Severidad de la Enfermedad , Cloruro de Sodio/administración & dosificación , Irrigación Terapéutica/métodos , Factores de Tiempo , Resultado del Tratamiento , Úlcera/diagnóstico , Úlcera/epidemiología , Cicatrización de Heridas
5.
J Arrhythm ; 32(3): 198-203, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27354865

RESUMEN

BACKGROUND: Catheter ablation of non-paroxysmal atrial fibrillation (non-PAF) is a therapeutic challenge especially in elderly patients. This study describes the feasibility of a posterior left atrium isolation as a substrate modification in addition to pulmonary vein isolation, the so-called Box isolation, for elderly patients with non-PAF. METHODS: Two hundred twenty-nine consecutive patients who underwent Box isolations for drug-refractory non-PAF were divided into two groups according to their age; younger group comprising 175 patients aged <75 years and elderly group comprising 54 patients aged ≥75 years. RESULTS: During 23.7±12.0 months of follow-up, the arrhythmia-free rates after one procedure were 53.1% in younger group versus 48.1% in elderly group (p=0.50). Following the second procedure, all patients had electrical conduction recoveries along the initial Box lesion. However, a complete Box re-isolation was highly established in both age groups (87.1% vs. 92.9%, respectively; p=1.00). Recurrence of macro-reentrant atrial tachycardia was mainly associated with the gaps through the initial Box lesion in both age groups (25.8% vs. 21.4%, p=1.00), but typical cavo-tricuspid isthmus (CTI) dependent atrial flutter was significantly observed in the elderly patients' group only (all events were observed within 6 months after the initial procedure; 3.2% vs. 28.6%, p=0.009). After two procedures, the arrhythmia-free rates increased to 73.1% in younger group versus 66.7% in elderly group (p=0.38). The occurrence rate of procedural-related complications did not differ between the two age groups, and there were no life-threatening complications even in elderly patients. CONCLUSIONS: Box isolation of non-PAF is effective and safe even in elderly patients. A prophylactic CTI ablation combined with Box isolation might be feasible to improve the long-term outcome.

6.
J Am Coll Cardiol ; 68(25): 2747-2757, 2016 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-28007137

RESUMEN

BACKGROUND: Point-by-point catheter ablation is an established treatment for drug-refractory paroxysmal atrial fibrillation (PAF). However, it is time consuming, requires excellent technique to achieve complete pulmonary vein (PV) isolation, and is associated with severe complications. OBJECTIVES: The purpose of this study was to evaluate the safety and effectiveness of a HotBalloon ablation (HBA) compared with antiarrhythmic drug therapy (ADT) for the treatment of PAF. METHODS: A prospective multicenter randomized controlled study was conducted in Japan. Patients with symptomatic PAF refractory to antiarrhythmic drugs (Class I to IV) were randomized to HBA or ADT at a 2:1 ratio and assessed for effectiveness in a comparable 9-month follow-up period. RESULTS: A total of 100 patients in the HBA group and 43 patients in the ADT group received treatment at 17 sites. HBA procedure produced acute complete PV isolation in 98.0% (392 of 400) of the PVs and in 93.0% (93 of 100) of patients in the HBA group. The chronic success rates after the 9-month effective evaluation period were 59.0% in the HBA group (n = 100) and 4.7% in the ADT group (n = 43; p < 0.001). The incidence of major complications was 11.2% (15 of 134 patients). The incidences of PV stenosis (>70%) and transient phrenic nerve injury were 5.2% and 3.7%, respectively. The mean fluoroscopy time was 49.4 ± 26.6 min (n = 134), and the mean procedure duration was 113.9 ± 31.9 min (n = 133). CONCLUSIONS: This study demonstrates the superiority of HBA compared with ADT for treatment of patients with PAF, and a favorable safety profile.


Asunto(s)
Técnicas de Ablación/instrumentación , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/métodos , Catéteres Cardíacos , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Japón , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Adulto Joven
8.
Circ Arrhythm Electrophysiol ; 2(3): 225-32, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19808472

RESUMEN

BACKGROUND: Atrial fibrillation originates mostly from the pulmonary vein (PV) foci or non-PV foci in the posterior left atrium (LA). The present study was designed to evaluate the feasibility and safety of a novel radiofrequency hot balloon catheter for the treatment of patients with atrial fibrillation by electrically isolating the posterior LA, including all PVs. METHODS AND RESULTS: One hundred consecutive patients with drug-resistant atrial fibrillation (63 paroxysmal, 37 persistent) were enrolled. The isolation of the PVs was performed by wedging the balloon at each PV antrum to create circumferential lesions in each case. Contiguous linear lesions were also created at the roof between the superior PVs and at the bottom of the posterior LA between the inferior PVs by dragging the balloon along the endocardium. Complete elimination of the posterior LA and PV potentials was achieved in all 100 cases, confirmed by either conventional or electro-anatomic mapping system. The total procedure time was 129+/-26 minutes, inclusive of 29.9+/-7.3 minutes of fluoroscopy time. Follow-up during 11.0+/-4.8 months confirmed that 92 patients (60 paroxysmal, 32 persistent) were free from atrial fibrillation without antiarrhythmic drugs, and in the remaining patients except for 2 with LA tachycardia, sinus rhythm was maintained with antiarrhythmic drugs. With precautions of esophageal cooling by irrigation dictated by temperature monitoring and monitoring phrenic nerve pacing, no LA-esophageal fistula or permanent phrenic nerve injury occurred. CONCLUSIONS: This feasibility study supports the safety and efficacy of radiofrequency hot balloon catheter for complete isolation of the posterior LA and PVs.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Complicaciones Posoperatorias/prevención & control , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Atrios Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Nervio Frénico/fisiología , Venas Pulmonares/fisiopatología , Temperatura , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 59(1): 26-33, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12720237

RESUMEN

Transradial coronary intervention (TRI) can be performed in elective patients with low incidence of access site complications. However, the feasibility of primary stent implantation by TRI is still not clear in patients with acute myocardial infarction (AMI). We prospectively randomized 149 patients out of 213 patients with AMI within 12 hr from onset into two groups: 77 patients treated by TRI (TRI group) and 72 patients by transfemoral coronary intervention (TFI; TFI group). We compared the incidences of major adverse cardiac events (MACE; repeat MI, target lesion revascularization, and cardiac death) during the initial hospitalization and 9-month follow-up periods in both groups. There were one patient who crossed over to the opposite arm, and two patients with severe bleeding complications in the TFI group. Background characteristics of patients were similar between the two groups. The success rate of reperfusion and the incidence of in-hospital MACE were similar in both groups (96.1% and 5.2% vs. 97.1% and 8.3% in TRI and TFI groups, respectively). In selected patients with AMI, primary stent implantation by TRI is feasible as compared to TFI.


Asunto(s)
Implantación de Prótesis Vascular/métodos , Infarto del Miocardio/terapia , Anciano , Análisis de Varianza , Distribución de Chi-Cuadrado , Femenino , Arteria Femoral , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Arteria Radial , Stents , Análisis de Supervivencia , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 59(3): 305-11, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12822146

RESUMEN

Percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) is still technically challenging. The use of tapered-tip guidewires in these lesions may improve the success rate of PCI. In order to avoid the needless radiation exposure or contrast consumption, we have to determine a guideline for the termination of procedures in these lesions. We retrospectively analyzed the data of 182 patients between April 1997 and December 1999 (phase 1) and 80 patients between January and August 2001 (phase 2) who underwent angioplasty for CTO lesions >/= 3 months. There were no significant differences in clinical or lesion characteristics except the use of tapered-tip guidewires. Tapered-tip guidewires were used in 60% of patients in phase 2 period but no patients in phase 1 period. The overall success rate of PCI was improved from 67% in phase 1 to 81% in phase 2 (P = 0.019). In the phase 2 period, the success rate was higher in tapered-type occlusion (P = 0.002) and shorter length of occlusion (P = 0.004). Total procedure time was 46 +/- 17 min and total volume of contrast dye was 180 +/- 63 ml. The success rate was higher in patients treated by transradial coronary intervention (TRI) than transfemoral coronary intervention (89% vs. 64%; P = 0.008). The use of tapered-tip guidewires can improve the success rate of PCI in CTO lesions. The following guideline for the termination of the procedures is reasonable: time from arterial access to successful penetration of a guidewire through occlusion

Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Anciano , Análisis de Varianza , Angioplastia Coronaria con Balón/métodos , Enfermedad Crónica , Estudios de Cohortes , Angiografía Coronaria/métodos , Estenosis Coronaria/mortalidad , Diseño de Equipo , Seguridad de Equipos , Femenino , Estudios de Seguimiento , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Probabilidad , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Insuficiencia del Tratamiento , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 63(4): 452-6, 2004 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15558766

RESUMEN

A 6 Fr guiding catheter is commonly used in the percutaneous coronary intervention (PCI). However, one of the limitations of the 6 Fr guiding catheter is its weak backup support compared to a 7 or an 8 Fr guiding catheter. In this article, we present a new system for PCI called the five-in-six system. Between March 2003 and September 2003, this system was tried on eight chronic total occlusion cases. The advantage of the five-in-six system is that it increases backup support of a 6 Fr guiding catheter.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/métodos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Enfermedad Coronaria/terapia , Adolescente , Anciano , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Diseño de Equipo , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 56(3): 328-32, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12112884

RESUMEN

Radial artery spasm is one of the major problems during transradial coronary intervention (TRI). The sheath introducer with hydrophilic coating may reduce the incidence of spasm and reduce the difficulty in removing it from the radial artery under the situation of spasm artery spasm. After we compared the friction resistance between the sheath introducer with hydrophilic coating and that without coating (nine samples each) in vitro, the sheath introducers with and without hydrophilic coating were randomly used in 37 and 36 patients, respectively, who underwent elective TRI with a 6 Fr introducer sheath. Hydrophilic coating of sheath introducer reduced friction resistance by 70% (P < 0.00001) in in vitro model and facilitated sheath removal after finishing TRI (P = 0.0003). Hydrophilic coating of sheath introducer is useful in TRI.


Asunto(s)
Cateterismo Periférico/instrumentación , Materiales Biocompatibles Revestidos , Arteria Radial , Cateterismo Periférico/métodos , Remoción de Dispositivos , Fricción , Humanos , Polímeros
13.
J Cardiovasc Electrophysiol ; 14(6): 609-15, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12875422

RESUMEN

INTRODUCTION: A rapidly firing or triggered ectopic focus located within a pulmonary vein (PV) or close to the PV ostium could induce atrial fibrillation (AF). The aim of this study was to evaluate the efficacy and safety of a radiofrequency thermal balloon catheter for isolation of the PV from the left atrium (LA). METHODS AND RESULTS: Twenty patients with drug-resistant paroxysmal AF were treated by isolating the superior PVs using an RF thermal balloon catheter. Using a transseptal approach, the balloon, which had an inflated diameter 5 to 10 mm larger than that of the PV ostium, was wedged at the LA-PV junction. It was heated by a very-high-frequency current (13.56 MHZ) applied to the coil electrode inside the balloon for 2 to 3 minutes, and the procedure was repeated up to four times. The balloon center temperature was maintained at 60 degrees to 75 degrees C by regulating generator output. Successful PV isolation was achieved in 19 of the 20 left superior PVs and in all 20 of the right superior PVs and was associated with a decrease in amplitude of the ostial potentials. Total procedure time was 1.8 +/- 0.5 hours, which included 22 +/- 7 minutes of fluoroscopy time. After a follow-up period of 8.1 +/- 0.8 months, 17 patients were free from AF, with 10 not taking any antiarrhythmic drugs and 7 taking the same antiarrhythmic agent as before ablation. Electron beam computed tomography revealed no complications, such as PV stenosis at ablation sites. CONCLUSION: The PV and its ostial region can be safely and quickly isolated from the LA by circumferential ablation around the PV ostia using a radiofrequency thermal balloon catheter for treatment of AF.


Asunto(s)
Ablación por Catéter , Cateterismo , Venas Pulmonares/cirugía , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Presión Sanguínea/fisiología , Angiografía Coronaria , Circulación Coronaria/fisiología , Electrocardiografía , Electrodos Implantados , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Estudios de Seguimiento , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Tabiques Cardíacos/diagnóstico por imagen , Tabiques Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Flebografía , Proyectos Piloto , Venas Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
14.
J Cardiol ; 41(3): 135-42, 2003 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-12674998

RESUMEN

A 43-year-old woman had undergone patch closure operation for atrial septal defect 27 years ago. She was referred to our hospital for evaluation of frequent palpitations since 1 year ago. Electrophysiological study was performed with recording of the coronary sinus, His bundle, and low lateral right free wall electrography utilizing a steerable duo-decapolar electrode catheter(Livewire, Daig). Supraventricular tachycardia with cycle length alternation of 300 and 320 msec similar to atrial flutter was reproducibly provoked by burst pacing from the coronary sinus. During the supraventricular tachycardia, abnormal atrial potentials occurred in the low lateral right free wall region with very low amplitude and splitting potentials. The cycle length alternation of the supraventricular tachycardia depended on the occurrence of the splitting potentials, that is, the splitting potentials were present during the supraventricular tachycardia with a long cycle and the splitting potentials were absent during the supraventricular tachycardia with a short cycle. This phenomenon suggested that the splitting potentials resulted from 2:1 functional intra-atrial local conduction block. In addition, during sinus rhythm the abnormal electrograms revealed fractionated activity. Thus, these findings strongly imply that the supraventricular tachycardia is due to a macro-reentrant right atrial tachycardia utilizing an anatomical obstacle caused by the atrial septal defect operation as a central area, namely incisional reentrant atrial tachycardia. Three-dimensional electroanatomical mapping using the CARTO system(Biosense-Webster) was conducted to investigate whether the low lateral right free wall area possessed the critical isthmus essential to the reentry circuit. Electroanatomical mapping revealed that the very low amplitude potentials and the splitting potentials corresponded to the scars and the functional conduction block area detected by mapping using the multipolar catheter, respectively. According to the propagation mapping, the incisional reentrant atrial tachycardia slowly conducted the channel created by multiple neighboring scars clockwise and the alternation of the tachycardia cycle length was dependent on the development of the functional local intra-atrial conduction block within the channel. An approximately 1.5 cm successful linear lesion was created by radiofrequency catheter ablation to transect the isthmus based on the electroanatomical mapping findings. Afterwards, the incisional reentrant atrial tachycardia could not be induced by burst stimuli from the coronary sinus even under administration of isoproterenol. The use of three dimensional electroanatomical mapping(CARTO system) to evaluate the reentry circuit after the detection of abnormal potentials by using multipolar catheter in advance is a very useful method to determine optimal target site of ablation for a patient with incisional reentrant atrial tachycardia.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Técnicas Electrofisiológicas Cardíacas , Taquicardia Atrial Ectópica/diagnóstico , Adulto , Ablación por Catéter , Cateterismo , Femenino , Defectos del Tabique Interatrial/cirugía , Humanos , Complicaciones Posoperatorias , Taquicardia Atrial Ectópica/etiología , Taquicardia Atrial Ectópica/fisiopatología , Taquicardia Atrial Ectópica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA