Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Electrocardiol ; 48(4): 729-33, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25796100

RESUMEN

Pulmonary vein isolation (PVI) using cryoballoon (CB) technique and cavotricuspid isthmus (CTI) ablation using radiofrequency (RF) are established interventions for drug-resistant atrial fibrillation (AF) and typical atrial flutter (AFL). Twelve patients with a mean age of 62 ± 12 years underwent simultaneous delivery of RF energy at the CTI during CB applications at the PV ostia. Pulmonary vein isolation was achieved in all PVs and sustained bidirectional CTI conduction block obtained in all patients. The reported ablation protocol of combined paroxysmal AF and typical AFL did not result in prolongation of the procedure duration or in prolonged radiation exposure when compared to CB-PVI alone. No interferences between both ablation energy systems were observed. These preliminary results suggest that combined paroxysmal AF and typical AFL can be successfully and safely ablated using hybrid energy sources with simultaneous CTI ablation using RF during CB applications at the PV ostia.


Asunto(s)
Fibrilación Atrial/cirugía , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Aleteo Atrial/complicaciones , Aleteo Atrial/diagnóstico , Terapia Combinada/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Válvula Tricúspide/cirugía
2.
Catheter Cardiovasc Interv ; 82(4): 556-9, 2013 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-22511530

RESUMEN

Aortic coarctation is an unusual cause of hypertension during pregnancy and its management is not clarified. We report transcatheter balloon dilatation and stenting for native aortic coarctation in a 22-year-old pregnant woman with severe and uncontrolled systemic hypertension. Arterial blood pressure could be successfully controlled with medical treatment during the rest of the pregnancy and the patient underwent uneventful delivery. No adverse events or recoarctation was observed during 24 months clinical follow-up. In conclusion, native aortic coarctation can be successfully treated during pregnancy with transcatheter therapy. More experience is needed to confirm the safety and efficacy of such management.


Asunto(s)
Angioplastia de Balón , Coartación Aórtica/terapia , Presión Arterial , Cateterismo Cardíaco , Hipertensión Inducida en el Embarazo/terapia , Angioplastia de Balón/instrumentación , Antihipertensivos/uso terapéutico , Coartación Aórtica/complicaciones , Coartación Aórtica/diagnóstico , Coartación Aórtica/fisiopatología , Aortografía , Presión Arterial/efectos de los fármacos , Femenino , Humanos , Hipertensión Inducida en el Embarazo/diagnóstico , Hipertensión Inducida en el Embarazo/etiología , Hipertensión Inducida en el Embarazo/fisiopatología , Nacimiento Vivo , Imagen por Resonancia Magnética , Embarazo , Índice de Severidad de la Enfermedad , Stents , Resultado del Tratamiento , Adulto Joven
3.
Pacing Clin Electrophysiol ; 36(1): 24-30, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23078045

RESUMEN

BACKGROUND: The Achieve catheter (AC; Medtronic-CryoCath, Pointe-Claire, Canada) is a circular mapping catheter introduced through the lumen of the cryoballoon (CB) catheter which is safe and effective to both navigate the CB to the pulmonary veins (PV) and allow PV potential recording during PV cryoablation. The aim of this study was to evaluate the impact of the use of the AC on procedural outcomes. METHODS: Sixteen consecutive patients (14 men) underwent AC-guided PV isolation (PVI) for drug-refractory paroxysmal atrial fibrillation (AF; AC group). Clinical and procedural data of these patients were compared to those obtained from 16 consecutive patients who had undergone PVI for paroxysmal AF with the regular "single transseptal" approach (control group). RESULTS: Clinical characteristics of patients enrolled in both groups did not differ significantly. In the AC group, 64 PVs were targeted using a single 28-mm (n = 13) or 23-mm (n = 3) CB catheter with PVI achieved in 62 PVs (97%). In the control group, 66 PVs were targeted using a single 28-mm (n = 12) or 23-mm (n = 4) CB catheter with PVI achieved in 62 PVs (94%), (P = non-significant for CB size and PVI rate). Procedure duration and fluoroscopy time were significantly reduced in AC group compared to control group (96.6 ± 26 minutes vs 125.9 ± 25 minutes, P = 0.003 and 24.4 ± 10 minutes vs 32.6 ± 11 minutes, P = 0.04, respectively). CONCLUSION: The use of the AC significantly reduced procedure duration and radiation exposure during PVI with the CB technique.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/instrumentación , Criocirugía/instrumentación , Dosis de Radiación , Cirugía Asistida por Computador/instrumentación , Tomografía Computarizada por Rayos X , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Protección Radiológica/métodos , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento
4.
Europace ; 14(1): 146-7, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21821853

RESUMEN

Numerous unusual causes of atrioventricular block (AVB) with cardiac pacemaker implantation have been documented including cough, deglutition, or other vagally mediated mechanism. In spinal cord lesions, only high cervical spinal cord lesion has been reported as a cause of severe bradycardia. We report a case with not cervical but dorsal vertebral trauma and persistent paroxysmal AVB requiring cardiac pacemaker implantation.


Asunto(s)
Estimulación Cardíaca Artificial , Paro Cardíaco/etiología , Paro Cardíaco/terapia , Marcapaso Artificial , Traumatismos de la Médula Espinal/complicaciones , Antiarrítmicos/uso terapéutico , Atropina/uso terapéutico , Bradicardia/etiología , Bradicardia/fisiopatología , Bradicardia/terapia , Vértebras Cervicales/lesiones , Electrocardiografía , Paro Cardíaco/tratamiento farmacológico , Humanos , Isoproterenol/uso terapéutico , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
5.
Pacing Clin Electrophysiol ; 35(4): 403-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22309354

RESUMEN

BACKGROUND: This study aimed to describe the influence on dual-chamber devices' expected longevity of devices' settings. METHODS: Data from patients implanted with dual chamber devices (Symphony™, SORIN CRM SAS, Clamart, France) from 2003 to 2006 were collected in registries. Programmer files were retrieved: device-estimated longevity, assessed through algorithm prediction, was analyzed according to device settings. RESULTS: One thousand sixty-eight recipients of dual chamber pacemaker in sinus rhythm (75.3±11.1 years, 54.5% male, ventricular block 30%, brady-tachy syndrome 21%, and sinus node dysfunction 49%) were followed up to 14.2±12.1 months (ranging from first quartile Q1: 2.9 months to fourth quartile Q4: 49.3 months) after implantation. DDD with automatic mode conversion and minimized ventricular pacing (SafeR) modes were programmed in 34.3%, 2.9%, and 62.8% of the patients, respectively. The mean total longevity estimated by the device was 134.1±31.5 months (11.2±2.6 years). Significant increase in longevity was observed in devices undergoing at least one reprogramming (134.4±31.4 months) versus device presenting no reprogramming (103.4±32.3 months, P=0.0005). The parameters associated with the major increase in mean longevity were the mode (mean longevity increase of +23.9 months in SafeR as compared to DDD mode, P<0.0001) and the atrial (A) and ventricular (V) amplitudes (mean longevity increase of +29.6 and +26.9 months for a decrease of less than 1V in A and V outputs respectively, P<0.0001). CONCLUSION: This study provides information on dual chamber pacemakers' longevity and highlights the impact of devices' reprogramming on expected longevities.


Asunto(s)
Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Algoritmos , Bradicardia/terapia , Estimulación Cardíaca Artificial/métodos , Femenino , Bloqueo Cardíaco/terapia , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Síndrome del Seno Enfermo/terapia , Síndrome , Taquicardia/terapia
6.
J Electrocardiol ; 45(4): 394-397, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22424842

RESUMEN

Ventricular allorhythmia is an electrocardiogram feature leading to a pattern of "regularly irregular" arrhythmia mainly reported during non-life-threatening organized atrial tachycardia. We report the infrequent case of a patient presenting with ventricular allorhythmia during infarct-related ventricular tachycardia. The potential mechanisms of this tachycardia are discussed.


Asunto(s)
Electrocardiografía , Infarto del Miocardio/complicaciones , Taquicardia Ventricular/fisiopatología , Función Ventricular , Anciano , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología
7.
Heart Rhythm ; 4(7): 870-6, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17599669

RESUMEN

BACKGROUND: Adenosine may play a role in the triggering of neurocardiogenic syncope, but no information on adenosine receptors is available at the present time. OBJECTIVE: The purpose of this study was to investigate whether adenosine A2A receptors expression is altered in patients with neurocardiogenic syncope. METHODS: Adenosine plasma levels (APLs), the expression of A2A receptors, were measured (mean +/- standard error of the mean) during tilt testing. Expression of receptors was assessed on mononuclear cells using a selective receptor ligand. RESULTS: At baseline, the APLs of 16 patients with a positive test were higher than those of 17 patients with a negative test and of those of a control group (2.10 +/- 0.30 vs. 0.40 +/- 0.05 and 0.41 +/- 0.06 muM, respectively; P <.0001). The number of receptors was higher in patients tested positive than in patients tested negative or in the control group (122 +/- 10 vs. 38 +/- 4 and 44 +/- 4 fmol/g of proteins, respectively; P <.0001). No difference was found in the affinity or synthesis among the three groups. CONCLUSION: This study showed an increased number and an up-regulation of adenosine A2A receptors in patients with spontaneous syncope and a positive head-up tilt, which in the context of high APLs may play a role in the recurrence of syncopal episodes.


Asunto(s)
Regulación de la Expresión Génica , Receptor de Adenosina A2A/metabolismo , Síncope/etiología , Síncope/metabolismo , Adenosina/metabolismo , Adolescente , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Receptor de Adenosina A2A/genética , Síncope/sangre
8.
Am J Cardiol ; 96(10): 1456-9, 2005 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-16275199

RESUMEN

The accuracy of the tissue Doppler E/Ea and color M-mode Doppler E/Vp indexes in diagnosing congestive heart failure (HF) was investigated in 20 chronic hypertensive patients with acute dyspnea and normal left ventricular ejection fractions who met Vasan's criteria for definite diastolic HF, compared with 20 gender- and age-matched hypertensive patients with noncardiac cause of acute dyspnea. The E/Ea ratio appeared to be more reproducible (variability 4% to 9% vs 6 to 14%) and more precise (sensitivity 77.8%, specificity 100%, and accuracy 89.5% for the optimal cutoff of 11 vs sensitivity 73.7%, specificity 75%, and accuracy 74.3% for the optimal cutoff of 1.5) than the E/Vp ratio in this clinical setting.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Ecocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Hipertensión/diagnóstico , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Enfermedad Crónica , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Servicios Médicos de Urgencia , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/fisiopatología , Humanos , Hipertensión/sangre , Hipertensión/fisiopatología , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Péptido Natriurético Encefálico/sangre , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Am J Cardiol ; 96(1): 104-7, 2005 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-15979445

RESUMEN

The imbalance of Starling's forces was investigated in 25 elderly patients hospitalized for acute diastolic heart failure. Tissue Doppler evidence of elevated left ventricular filling pressures was present on admission in 17 patients with high B-type natriuretic peptide (BNP) levels. Serum proteins concentrations and colloid osmotic pressure, related to malnutrition and severe sepsis, were significantly less in the 8 patients without tissue Doppler evidence of elevated filling pressures, and a high level of BNP was consistent with paroxysmal elevation in filling pressures in this setting.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/patología , Ventrículos Cardíacos/diagnóstico por imagen , Péptido Natriurético Encefálico/sangre , Enfermedad Aguda , Factores de Edad , Anciano , Anciano de 80 o más Años , Diástole , Femenino , Humanos , Pacientes Internos , Masculino , Ultrasonografía Doppler , Disfunción Ventricular Izquierda
10.
J Interv Card Electrophysiol ; 9(1): 25-7, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12975567

RESUMEN

This is the first report of intracardiac thrombi and pulmonary embolism complicating pacemaker leads implanted for cardiac resynchronization therapy. Prompt diagnosis and successful therapy with a thrombolytic agent lead to a favourable outcome. This report suggests that long-term oral anticoagulation should be considered in patients with depressed left ventricular function undergoing cardiac resynchronization therapy in order to prevent this potentially serious complication.


Asunto(s)
Cardiopatías/etiología , Marcapaso Artificial/efectos adversos , Embolia Pulmonar/etiología , Trombosis/etiología , Anciano , Cardiopatías/tratamiento farmacológico , Humanos , Masculino , Embolia Pulmonar/tratamiento farmacológico , Terapia Trombolítica , Trombosis/tratamiento farmacológico
11.
Heart Rhythm ; 11(6): 1024-30, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24589867

RESUMEN

BACKGROUND: Patients with short QT syndrome (SQTS) have an increased risk for atrial tachyarrhythmias, ventricular tachyarrhythmias, and/or sudden cardiac death. PQ segment depression (PQD) is related to atrial fibrillation and carries a poor prognosis in the setting of acute inferior myocardial infarction and is a well-defined electrocardiographic (ECG) marker of acute pericarditis. OBJECTIVE: To evaluate the prevalence of PQD in SQTS and to analyze the association with atrial arrhythmias. METHODS: Digitalized 12-lead ECGs of SQTS patients were evaluated for PQD in all leads and for QT intervals in leads II and V5. PQD was defined as ≥0.05 mV (0.5 mm) depression from the isoelectric line. RESULTS: A total of 760 leads from 64 SQTS patients (mean age 36 ± 18 years; 48 [75%] men) were analyzed. PQD was seen in 265 (35%) leads from 52 (81%) patients and was more frequent in leads II, V3, aVF, V4, and I (n = 43 [67%], n = 30 [47%], n = 27 [42%], n = 25 [39%], and n = 25 [39%], respectively). Nine of 64 (14%) patients presented with atrial tachyarrhythmias, and all of them had PQD. CONCLUSION: Fifty-two of 64 (81%) patients with SQTS reveal PQD. As PQD is rarely observed in healthy individuals, this ECG stigma may constitute a novel marker for SQTS in addition to a short QT interval.


Asunto(s)
Sistema de Conducción Cardíaco/fisiopatología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Niño , Preescolar , Electrocardiografía Ambulatoria/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Canales de Potasio de Rectificación Interna/fisiología , Pronóstico , Adulto Joven
12.
J Cardiovasc Transl Res ; 6(3): 398-403, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23149816

RESUMEN

Dual antiplatelet therapy with aspirin and clopidogrel dramatically reduced the rate of major adverse cardiac events following percutaneous coronary intervention. Clopidogrel is a prodrug which requires a two-step hepatic biotransformation thanks to the cytochrome P450 (CYP450) enzyme system. Genetic polymorphism of CYP450 system (e.g., CYP2C19*2) responsible for altered clopidogrel metabolism is a major cause of high on-treatment platelet reactivity (HTPR), which translates into thrombotic events in stented patients. Studies demonstrated that HTPR could be overcome in poor metabolizers thanks to increased loading doses or maintenance doses of clopidogrel or with the use of more potent antiplatelet agents such as prasugrel. Other genetic polymorphisms have also been correlated with HTPR: ABCB1, ATP2B2, and TIAM2. Large-scale randomized trials with clinical endpoints remain necessary to determine the optimal antiplatelet therapy in patients carrying genetic polymorphism associated with HTPR and thrombotic events.


Asunto(s)
Plaquetas/efectos de los fármacos , Trombosis Coronaria/prevención & control , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Ticlopidina/análogos & derivados , Animales , Hidrocarburo de Aril Hidroxilasas/genética , Hidrocarburo de Aril Hidroxilasas/metabolismo , Biotransformación , Plaquetas/metabolismo , Clopidogrel , Trombosis Coronaria/sangre , Trombosis Coronaria/etiología , Citocromo P-450 CYP2C19 , Resistencia a Medicamentos , Genotipo , Humanos , Selección de Paciente , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Farmacogenética , Fenotipo , Inhibidores de Agregación Plaquetaria/farmacocinética , Polimorfismo Genético , Medicina de Precisión , Stents , Ticlopidina/farmacocinética , Ticlopidina/uso terapéutico , Resultado del Tratamiento
13.
Int J Cardiol ; 168(1): 108-11, 2013 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-23044433

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) using cryoballoon (CB) catheter is a new technique for atrial fibrillation (AF) ablation. Previous studies used computer tomography (CT) or magnetic resonance imaging (MRI) scan to determine the pulmonary vein (PV) diameter and anatomy for choosing the CB size. We evaluated pre-ablation transoesophageal-echocardiography (TEE) as an alternative to CT/MRI scan in patients undergoing AF ablation for determining the appropriate size of the CB. METHODS: Fifty-five consecutive patients (men=43, women=12) with a mean age of 63 ± 12.5 years, and with drug-refractory paroxysmal AF (34 patients) or persistent AF (21 patients) were included in this prospective study. All patients underwent pre-ablation TEE. RESULTS: Hypertension was present in 19 patients (34%). Mean anterior-posterior left atrium diameter was 45.1 ± 8.9 mm. In total, 217 PV were targeted using a single 23-mm (n=14) or 28-mm (n=40) CB catheter chosen according to TEE-obtained measurements. PVI was achieved in 195 PV (90%). Mean number of CB applications per patient was 9.8 ± 2.1 (range 8-14). Mean procedure duration and fluoroscopy times were 131 ± 27 min (90-190 min) and 36 ± 12 min (22-66 min) respectively. Phrenic nerve palsy occurred in 3 patients (5.4%) and was transient (<1 month) in all of them. CONCLUSION: This study suggests that TEE is an easily available and effective tool to select the size of the CB for PVI according to evaluated PV diameters and anatomy.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Criocirugía/métodos , Ecocardiografía Transesofágica/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
14.
J Interv Card Electrophysiol ; 37(1): 105-9, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23247421

RESUMEN

PURPOSE: The 9-French 8-mm tip cryoablation catheter confers a high rate of acute slow pathway (SP) elimination and an acceptable short-term outcome in patients with atrioventricular nodal reentrant tachycardia (AVNRT). The aim of this study was to investigate the long-term outcome of patients treated with this electrode in this indication. METHODS: Eighty-two patients (female = 52) with a mean age of 54.9 ± 17.7 years underwent SP elimination for typical AVNRT with the 8-mm tip cryocatheter in our institution between November 2009 to June 2012. Clinical and procedural characteristics were prospectively collected. RESULTS: Acute procedural success defined as AVNRT non-inducibility at the end of the procedure was obtained in 81/82 patients (98.7 %). Mean procedure duration and fluoroscopy time were 74.4 ± 28.7 min (range, 35-160 min) and 8.7 ± 5.3 min (range, 2-26 min), respectively. Mean number of energy applications was 4.0 ± 2.4 (range, 2-15). No permanent atrioventricular block was observed. Transient atrioventricular block occurred in 12 patients (14.6 %). Traumatic fast pathway conduction block occurred in one patient before cryoenergy delivery. Using an intention-to-treat analysis, 78 patients (95.1 %) remained free of AVNRT recurrence during a mean follow-up of 17.8 ± 9.3 months. CONCLUSIONS: This study confirmed that the 8-mm tip cryocatheter is both safe and highly effective for SP conduction elimination in patients with AVNRT and demonstrated a low recurrence rate during a long-term follow-up.


Asunto(s)
Criocirugía/instrumentación , Criocirugía/estadística & datos numéricos , Sistema de Conducción Cardíaco/anomalías , Sistema de Conducción Cardíaco/cirugía , Taquicardia por Reentrada en el Nodo Atrioventricular/epidemiología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Medición de Riesgo , Resultado del Tratamiento
15.
J Interv Card Electrophysiol ; 32(3): 181-6, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21833514

RESUMEN

Early repolarization (ER) pattern has been recognized for several decades and was interpreted as a variant of the normal electrocardiogram (ECG) as it was frequently observed in young healthy subjects or athletes. It is characterized by a J point elevation and ST-segment elevation inscribed as a QRS slurring or a notch of the S wave in the inferior leads or/and the lateral leads. The ER pattern has been the subject of increased interest since the report of its higher prevalence in subjects resuscitated from cardiac arrest related to idiopathic ventricular fibrillation (VF). Furthermore, population-based studies showed in healthy young adults that ER pattern was associated with an increased cardiovascular mortality and total mortality. A relationship between ER pattern and malignant arrhythmias is also supported by the experimental work of Antzelevitch et al. which provided the cellular and ionic basis for the J point elevation and its arrhythmogenic potential. The ER pattern may coexist with a number of cardiac or extracardiac conditions such as hypothermia. But this review will focus attention on the "isolated ER pattern" in healthy individuals. Antzelevitch and Yan proposed because of a number of similarities between the "ER syndrome" and the Brugada syndrome to group both syndromes under the heading of "J wave syndromes". The management of ER syndrome (associated with idiopathic VF) is clearly the insertion of an implantable cardioverter defibrillator (ICD). The ER pattern associated with symptoms such as syncope or a familial history of sudden cardiac death requires a complete work-up. Caution should be raised not to generate anxiety in the subject with asymptomatic "isolated ER pattern" as the odds of developing malignant ventricular arrhythmias or to suffer sudden death in this case are extremely low.


Asunto(s)
Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía/métodos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/terapia , Diagnóstico Diferencial , Humanos , Síndrome
16.
Arch Cardiovasc Dis ; 104(10): 530-5, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22044706

RESUMEN

BACKGROUND: Atrial flutter (AFL) and atrial fibrillation (AF) are "fellow-travellers". AF may be a stable, "isolated" rhythm, a bridge between sinus rhythm and AF, or both arrhythmias can coexist. Whether the characteristics of isolated AFL are different from those of patients with AFL combined with AF is still unclear. AIM: To compare the clinical characteristics of patients with isolated AFL to those of patients with AFL combined with AF, in a series of patients referred for AFL ablation. METHODS: Seventy-six consecutive patients (mean age 66.9±12.2 years; 53 men) with a history of electrocardiogram-documented paroxysmal or persistent AFL, referred for catheter ablation, underwent clinical work-up including bidimensional echocardiogram. Patients were subdivided into group I (44 with isolated AFL) and group II (32 with AFL and a history of AF). RESULTS: Underlying heart disease was present in 62 patients (81.6%). Hypertension was the most common cardiac disorder (n=44, 57.9%) and was more prevalent in group II than in group I (75.0% vs 45.5%; P=0.01). Prevalence of prior cardiac surgery was higher in group I (22.7% vs 6.3%; P=0.04). AFL was persistent in 35 group I patients and 17 group II patients (79.5% vs 53.1%; P=0.01). Class I or III antiarrhythmic drug use was more frequent in group II (84.4% vs 45.5%; P=0.001). CONCLUSION: This study showed significant differences between patients with isolated AFL and those with AFL combined with AF, in the prevalence of underlying heart disease and the use of antiarrhythmic medication, which were higher when both atrial arrhythmias were combined. In turn, the history of cardiac surgery (including atriotomy), was more common in patients with isolated AFL than in those with AFL combined with AF.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Adulto , Anciano , Anciano de 80 o más Años , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Aleteo Atrial/diagnóstico , Aleteo Atrial/epidemiología , Aleteo Atrial/terapia , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ablación por Catéter , Distribución de Chi-Cuadrado , Comorbilidad , Ecocardiografía , Electrocardiografía , Femenino , Francia , Cardiopatías/epidemiología , Humanos , Hipertensión/epidemiología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Estudios Retrospectivos , Factores de Riesgo
17.
J Am Coll Cardiol ; 58(6): 587-95, 2011 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-21798421

RESUMEN

OBJECTIVES: The aim of this study was to investigate the clinical characteristics and the long-term course of a large cohort of patients with short QT syndrome (SQTS). BACKGROUND: SQTS is a rare channelopathy characterized by an increased risk of sudden death. Data on the long-term outcome of SQTS patients are not available. METHODS: Fifty-three patients from the European Short QT Registry (75% males; median age: 26 years) were followed up for 64 ± 27 months. RESULTS: A familial or personal history of cardiac arrest was present in 89%. Sudden death was the clinical presentation in 32%. The average QTc was 314 ± 23 ms. A mutation in genes related to SQTS was found in 23% of the probands; most of them had a gain of function mutation in HERG (SQTS1). Twenty-four patients received an implantable cardioverter defibrillator, and 12 patients received long-term prophylaxis with hydroquinidine (HQ), which was effective in preventing the induction of ventricular arrhythmias. Patients with a HERG mutation had shorter QTc at baseline and a greater QTc prolongation after treatment with HQ. During follow-up, 2 already symptomatic patients received appropriate implantable cardioverter defibrillator shocks and 1 had syncope. Nonsustained polymorphic ventricular tachycardia was recorded in 3 patients. The event rate was 4.9% per year in the patients without antiarrhythmic therapy. No arrhythmic events occurred in patients receiving HQ. CONCLUSIONS: SQTS carries a high risk of sudden death in all age groups. Symptomatic patients have a high risk of recurrent arrhythmic events. HQ is effective in preventing ventricular tachyarrhythmia induction and arrhythmic events during long-term follow-up.


Asunto(s)
Arritmias Cardíacas/terapia , Adolescente , Adulto , Antiarrítmicos/farmacología , Estudios de Cohortes , Muerte Súbita , Desfibriladores Implantables , Canal de Potasio ERG1 , Electrocardiografía/métodos , Canales de Potasio Éter-A-Go-Go/genética , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Mutación , Quinidina/análogos & derivados , Quinidina/farmacología , Síncope/patología , Resultado del Tratamiento
18.
Cardiovasc Revasc Med ; 11(3): 159-62, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20599166

RESUMEN

BACKGROUND: In patients under oral anticoagulant requiring percutaneous coronary intervention (PCI) with stent implantation, the optimal association between aspirin, clopidogrel and oral anticoagulant (OAC) remains cumberstome. Triple therapy and dual therapy using aspirin and OAC have been evaluated and are associated with a high frequency of major bleedings. The combination of clopidogrel and OAC has never been evaluated. OBJECTIVE: We aimed to investigate the safety and efficacy of clopidogrel and OAC in patients requiring OAC undergoing PCI for acute coronary syndrome. METHODS: A monocenter retrospective study was undertaken between 2000 and 2006 and included all patients undergoing PCI with stent implantation on OAC. On discharge dual therapy with clopidogrel and OAC was prescribed. The primary end-point was the frequency of major TIMI bleedings. Secondary end-points were major cardiovascular event (MACE). Results are reported as rate of events with 95% confidence intervals (CI). RESULTS: Two hundreds and nine patients were followed for 71 +/- 22 months. The indication for oral anticoagulation was atrial fibrillation in 80% of patients, a valvular prothesis in 18% and a history of pulmonary embolism in 5%. The rate (95%CI) of major bleeding was 2.4% (0.9%-5.8%) 2.87% (1.17%-6.44%) and 3.8% (1.79%-7.68%) at 1 month, 12 months and 71 months respectively, which represent 8 events among which 2 were fatal. The MACE rate (95%CI) was low: 0% at one month, 3.8% (1.79%-7.68%) at 12 months and 24.4% (19.07%-30.65%) at 71 months of follow up. Only one stent thrombosis was recorded at the ninth month. The overall rate of death was 9.5% (6.28%-14.32%) among which 2.87% (1.17%-6.44%) were of cardiovascular origin. CONCLUSION: The use of clopidogrel and OAC combination in patients on OAC undergoing coronary stenting is safe and efficient at the short-term. At the long-term, this combination is probably not safe, with a relatively high incidence of fatal stroke.


Asunto(s)
Síndrome Coronario Agudo/tratamiento farmacológico , Angioplastia Coronaria con Balón/métodos , Ticlopidina/análogos & derivados , Warfarina/administración & dosificación , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Síndrome Coronario Agudo/terapia , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Clopidogrel , Estudios de Cohortes , Intervalos de Confianza , Angiografía Coronaria , Relación Dosis-Respuesta a Droga , Esquema de Medicación , Quimioterapia Combinada , Femenino , Estudios de Seguimiento , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Humanos , Masculino , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Stents , Tasa de Supervivencia , Trombosis/inducido químicamente , Trombosis/epidemiología , Ticlopidina/administración & dosificación , Ticlopidina/efectos adversos , Factores de Tiempo , Warfarina/efectos adversos
19.
Arch Cardiovasc Dis ; 103(1): 3-9, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20142114

RESUMEN

BACKGROUND: B-type natriuretic peptide (BNP) and left atrial volume index (LAVi) are used as surrogate measures for global myocardial function and are recommended for the diagnosis of heart failure with normal ejection fraction. Little is known, however, about predictors in patients with preserved systolic function. AIMS: To identify factors that influence the relation of BNP and left atrial size to invasively determined left ventricular end-diastolic pressure in stable patients with preserved left ventricular systolic function. METHODS: Fifty-nine consecutive patients were included prospectively. Clinical, biological, Doppler echocardiographic and invasive variables were collected simultaneously. RESULTS: BNP was predicted independently by left ventricular ejection fraction, diastolic function and age (p<0.05). LAVi was predicted independently by left ventricular mass index and invasive left ventricular end-diastolic pressure (p<0.01). BNP predicted increased left ventricular end-diastolic pressure greater than 16 mmHg (p=0.004); the optimal cut-off value was 33 pg/mL (area under the receiver-operating characteristic curve [AUC] 0.74 [0.6-0.84], p<0.001, sensitivity 72%, specificity 70%). LAVi predicted increased left ventricular end-diastolic pressure (p<0.001); the optimal cut-off value for LAVi was 26 mL/m(2) (AUC 0.87 [0.75-0.94], p<0.001; sensitivity 85%, specificity 80%). Unlike BNP (p=0.1), LAVi performed well in patients with abnormal relaxation at mitral filling (p<0.01). CONCLUSION: BNP is influenced by age in stable patients with preserved systolic function and should be interpreted cautiously. LAVi is a powerful surrogate for invasively determined left ventricular end-diastolic pressure regardless of age and mitral filling.


Asunto(s)
Cateterismo Cardíaco , Ecocardiografía Doppler , Insuficiencia Cardíaca/diagnóstico , Péptido Natriurético Encefálico/sangre , Función Ventricular Izquierda , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Femenino , Atrios Cardíacos/diagnóstico por imagen , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sensibilidad y Especificidad , Volumen Sistólico , Sístole , Presión Ventricular
20.
Int J Cardiol ; 145(2): 370-372, 2010 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-20207431

RESUMEN

Recent advances have highlighted the clinical relevance of pulmonary artery hypertension in terms of diagnosis and prognosis in heart failure with normal ejection fraction. We addressed the usefulness of Doppler-derived pulmonary artery systolic pressure to predict heart failure with normal ejection fraction in stable patients with exertional dyspnea. 25 patients referred for clinically indicated catheterism with evidence of heart failure according to the European diagnostic flowchart on "how to diagnose heart failure with normal ejection fraction" and 12 controls referred for clinically indicated catheterism without this condition according to the diagnostic flowchart on "how to exclude heart failure with normal ejection fraction" were included. None of the patients presented with Doppler-derived pulmonary vascular resistance >2.5 WU. By logistic regression analysis, pulmonary artery systolic pressure predicted heart failure with normal ejection fraction (p=0.006), with an optimal cut-off value of 35 mmHg (area under the ROC curve of 0.80 [0.64-0.92], p<0.001; sensitivity 76%, specificity 75%). Positive and negative predictive values were 93 and 50% for the cut-off value of 40 mmHg. Doppler-derived pulmonary artery hypertension is a landmark of heart failure with normal ejection fraction in patients without severely increased pulmonary vascular resistance and deserves further attention in upcoming international recommendations.


Asunto(s)
Ecocardiografía Doppler/normas , Insuficiencia Cardíaca/diagnóstico por imagen , Hipertensión Pulmonar/diagnóstico por imagen , Volumen Sistólico/fisiología , Anciano , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Hipertensión Pulmonar/complicaciones , Hipertensión Pulmonar/fisiopatología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA