Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Radiology ; 306(3): e221200, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36346312

RESUMEN

Background Posttraumatic CT imaging of the elbow can be challenging when patient mobility is limited. Gantry-free cone-beam CT (CBCT) with a twin robotic radiography system offers greater degrees of positioning freedom for three-dimensional elbow scans over gantry-based multidetector CT (MDCT), but studies analyzing their clinical value remain lacking. Purpose To investigate the diagnostic performance of gantry-free CBCT versus two-dimensional radiography in adults and children with acute elbow trauma. Materials and Methods In a retrospective study, consecutive patients with elbow trauma and positioning difficulty in a gantry-based MDCT who underwent three-dimensional elbow imaging with a gantry-free CBCT after radiography were enrolled between January 2021 and April 2022 at a tertiary care university hospital. Imaging data sets were independently analyzed for fracture presence, articular involvement, and multi-fragment injuries by three radiologists. Diagnostic performance was calculated individually with surgical reports serving as the reference standard. Differences between radiography and CBCT were compared with the McNemar test. Diagnostic confidence was estimated subjectively by each reader, and results were compared with the Wilcoxon signed-rank test. Results Elbow examinations of 23 adults and children (mean age ± SD, 49 years ± 23; seven women) were included with individual assessment of humerus, radius, and ulna (69 bones; 36 fractured). Multi-fragmentary fracture patterns and involvement of articular surfaces were ascertained in 28 and 30 bones, respectively. CBCT allowed for similar or higher sensitivity compared with radiography in the assessment of fractures (range for three readers, 94%-100% vs 72%-81%; respectively, P ≤ .06-.008), articular surface involvement (90%-97% vs 73%-87%; P ≤ .25), and multi-fragmentary patterns (96%-96% vs 68%-75%; P ≤ .03). Readers' diagnostic confidence improved considerably with access to CBCT data sets versus radiographs (all P ≤ .001). For CBCT, the median dose-length product was 70.9 mGy · cm, and the volume CT dose index was 4.4 mGy. Conclusion In acute elbow injuries, gantry-free cone-beam CT enabled improved detection of fractures, articular involvement, and multi-fragmentary patterns compared with two-dimensional radiography. Published under a CC BY 4.0 license Online supplemental material is available for this article.


Asunto(s)
Fracturas Óseas , Procedimientos Quirúrgicos Robotizados , Adulto , Niño , Humanos , Femenino , Dosis de Radiación , Codo , Estudios Retrospectivos , Tomografía Computarizada de Haz Cónico/métodos , Fracturas Óseas/diagnóstico por imagen
2.
Radiology ; 307(2): e220753, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36625744

RESUMEN

Background Ultrahigh-field-strength MRI at 7 T may permit superior visualization of noninflammatory wrist pathologic conditions, particularly due to its high signal-to-noise ratio compared with the clinical standard of 3 T, but direct comparison studies are lacking. Purpose To compare the subjective image quality of 3-T and 7-T ultrahigh-field-strength wrist MRI through semiquantitative scoring of multiple joint tissues in a multireader study. Materials and Methods In this prospective study, healthy controls and participants with chronic wrist pain underwent 3-T and 7-T MRI (coronal T1-weighted turbo spin-echo [TSE], coronal fat-suppressed proton-density [PD]-weighted TSE, transversal T2-weighted TSE) on the same day, from July 2018 to June 2019. Images were scored by seven musculoskeletal radiologists. The overall image quality, presence of artifacts, homogeneity of fat suppression, and visualization of cartilage, the triangular fibrocartilage complex (TFCC), and scapholunate and lunotriquetral ligaments were semiquantitatively assessed. Pairwise differences between 3 T and 7 T were assessed using the Wilcoxon signed-rank test. Interreader reliability was determined using the Fleiss kappa. Results In total, 25 healthy controls (mean age, 25 years ± 4 [SD]; 13 women) and 25 participants with chronic wrist pain (mean age, 39 years ± 16; 14 men) were included. Overall image quality (P = .002) and less presence of artifacts at PD-weighted fat-suppressed MRI were superior at 7 T. T1- and T2-weighted MRI were superior at 3 T (both P < .001), as was fat suppression (P < .001). Visualization of cartilage was superior at 7 T (P < .001), while visualization of the TFCC (P < .001) and scapholunate (P = .048) and lunotriquetral (P = .04) ligaments was superior at 3 T. Interreader reliability showed slight to substantial agreement for the detected pathologic conditions (κ = 0.20-0.64). Conclusion A 7-T MRI of the wrist had potential advantages over 3-T MRI, particularly in cartilage assessment. However, superiority was not shown for all parameters; for example, visualization of the triangular fibrocartilage complex and wrist ligaments was superior at 3 T. © RSNA, 2023 Supplemental material is available for this article.


Asunto(s)
Dolor Crónico , Muñeca , Masculino , Humanos , Femenino , Adulto , Estudios Prospectivos , Reproducibilidad de los Resultados , Articulación de la Muñeca/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Artralgia
3.
Eur Radiol ; 33(9): 6322-6338, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37191922

RESUMEN

OBJECTIVES: The purpose of this agreement was to establish evidence-based consensus statements on imaging of distal radioulnar joint (DRUJ) instability and triangular fibrocartilage complex (TFCC) injuries by an expert group using the Delphi technique. METHODS: Nineteen hand surgeons developed a preliminary list of questions on DRUJ instability and TFCC injuries. Radiologists created statements based on the literature and the authors' clinical experience. Questions and statements were revised during three iterative Delphi rounds. Delphi panelists consisted of twenty-seven musculoskeletal radiologists. The panelists scored their degree of agreement to each statement on an 11-item numeric scale. Scores of "0," "5," and "10" reflected complete disagreement, indeterminate agreement, and complete agreement, respectively. Group consensus was defined as a score of "8" or higher for 80% or more of the panelists. RESULTS: Three of fourteen statements achieved group consensus in the first Delphi round and ten statements achieved group consensus in the second Delphi round. The third and final Delphi round was limited to the one question that did not achieve group consensus in the previous rounds. CONCLUSIONS: Delphi-based agreements suggest that CT with static axial slices in neutral rotation, pronation, and supination is the most useful and accurate imaging technique for the work-up of DRUJ instability. MRI is the most valuable technique in the diagnosis of TFCC lesions. The main indication for MR arthrography and CT arthrography are Palmer 1B foveal lesions of the TFCC. CLINICAL RELEVANCE STATEMENT: MRI is the method of choice for assessing TFCC lesions, with higher accuracy for central than peripheral abnormalities. The main indication for MR arthrography is the evaluation of TFCC foveal insertion lesions and peripheral non-Palmer injuries. KEY POINTS: • Conventional radiography should be the initial imaging technique in the assessment of DRUJ instability. CT with static axial slices in neutral rotation, pronation, and supination is the most accurate method for evaluating DRUJ instability. • MRI is the most useful technique in diagnosing soft-tissue injuries causing DRUJ instability, especially TFCC lesions. • The main indications for MR arthrography and CT arthrography are foveal lesions of the TFCC.


Asunto(s)
Inestabilidad de la Articulación , Fibrocartílago Triangular , Traumatismos de la Muñeca , Humanos , Fibrocartílago Triangular/diagnóstico por imagen , Traumatismos de la Muñeca/diagnóstico por imagen , Imagen por Resonancia Magnética , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/cirugía , Artrografía , Articulación de la Muñeca/diagnóstico por imagen , Artroscopía/métodos
4.
BMC Musculoskelet Disord ; 23(1): 284, 2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35331212

RESUMEN

BACKGROUND: In wrist arthrograms, aberrant contrast material is frequently seen extending into the soft tissue adjacent to the ulnar styloid process. Since the prestyloid recess can mimic contrast leakage in CT arthrography, this study aims to provide a detailed analysis of its morphologic variability, while investigating whether actual ulnar-sided leakage is associated with injuries of the triangular fibrocartilage complex (TFCC). METHODS: Eighty-six patients with positive wrist trauma history underwent multi-compartment CT arthrography (40 women, median age 44.5 years). Studies were reviewed by two board-certified radiologists, who documented the morphology of the prestyloid recess regarding size, opening type, shape and position, as well as the presence or absence of ulnar-sided contrast leakage. Correlations between leakage and the presence of TFCC injuries were assessed using the mean square contingency coefficient (rɸ). RESULTS: The most common configuration of the prestyloid recess included a narrow opening (73.26%; width 2.26 ± 1.43 mm), saccular shape (66.28%), and palmar position compared to the styloid process (55.81%). Its mean length and anterior-posterior diameter were 6.89 ± 2.36 and 5.05 ± 1.97 mm, respectively. Ulnar-sided contrast leakage was reported in 29 patients (33.72%) with a mean extent of 12.30 ± 5.31 mm. Leakage occurred more often in patients with ulnar-sided TFCC injuries (rɸ = 0.480; p < 0.001), whereas no association was found for lesions of the central articular disc (rɸ = 0.172; p = 0.111). CONCLUSIONS: Since ulnar-sided contrast leakage is more common in patients with peripheral TFCC injuries, distinction between an atypical configuration of the prestyloid recess and actual leakage is important in CT arthrography of the wrist.


Asunto(s)
Artrografía , Muñeca , Adulto , Femenino , Humanos , Tomografía Computarizada por Rayos X , Cúbito/diagnóstico por imagen , Cúbito/patología , Articulación de la Muñeca/diagnóstico por imagen
5.
Eur Radiol ; 31(12): 9399-9407, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34003353

RESUMEN

OBJECTIVES: Triangular fibrocartilage complex (TFCC) injuries frequently cause ulnar-sided wrist pain and can induce distal radioulnar joint instability. With its complex three-dimensional structure, diagnosis of TFCC lesions remains a challenging task even in MR arthrograms. The aim of this study was to assess the added diagnostic value of radial reformatting of isotropic 3D MRI datasets compared to standard planes after direct arthrography of the wrist. METHODS: Ninety-three patients underwent wrist MRI after fluoroscopy-guided multi-compartment arthrography. Two radiologists collectively analyzed two datasets of each MR arthrogram for TFCC injuries, with one set containing standard reconstructions of a 3D thin-slice sequence in axial, coronal and sagittal orientation, while the other set comprised an additional radial plane view with the rotating center positioned at the ulnar styloid. Surgical reports (whenever available) or radiological reports combined with clinical follow-up served as a standard of reference. In addition, diagnostic confidence and assessability of the central disc and ulnar-sided insertions were subjectively evaluated. RESULTS: Injuries of the articular disc, styloid and foveal ulnar attachment were present in 20 (23.7%), 10 (10.8%) and 9 (9.7%) patients. Additional radial planes increased diagnostic accuracy for lesions of the styloid (0.83 vs. 0.90; p = 0.016) and foveal (0.86 vs. 0.94; p = 0.039) insertion, whereas no improvement was identified for alterations of the central cartilage disc. Readers' confidence (p < 0.001) and assessability of the ulnar-sided insertions (p < 0.001) were superior with ancillary radial reformatting. CONCLUSIONS: Access to the radial plane view of isotropic 3D sequences in MR arthrography improves diagnostic accuracy and confidence for ulnar-sided TFCC lesions. KEY POINTS: • In multi-compartment arthrography of the wrist, ancillary radial plane view aids assessability of the foveal and styloid ulnar-sided insertions of the triangular fibrocartilage complex. • Assessment of peripheral TFCC injuries is more accurate with access to radial multiplanar reconstructions. • Additional radial planes provide greater diagnostic confidence.


Asunto(s)
Fibrocartílago Triangular , Traumatismos de la Muñeca , Artrografía , Humanos , Imagen por Resonancia Magnética , Fibrocartílago Triangular/diagnóstico por imagen , Muñeca , Traumatismos de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca/diagnóstico por imagen
6.
Eur Radiol ; 31(12): 9446-9458, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34100996

RESUMEN

OBJECTIVES: The purpose of this agreement was to establish evidence-based consensus statements on imaging of scapholunate joint (SLJ) instability by an expert group using the Delphi technique. METHODS: Nineteen hand surgeons developed a preliminary list of questions on SLJ instability. Radiologists created statements based on the literature and the authors' clinical experience. Questions and statements were revised during three iterative Delphi rounds. Delphi panellists consisted of twenty-seven musculoskeletal radiologists. The panellists scored their degree of agreement to each statement on an eleven-item numeric scale. Scores of '0', '5' and '10' reflected complete disagreement, indeterminate agreement and complete agreement, respectively. Group consensus was defined as a score of '8' or higher for 80% or more of the panellists. RESULTS: Ten of fifteen statements achieved group consensus in the second Delphi round. The remaining five statements achieved group consensus in the third Delphi round. It was agreed that dorsopalmar and lateral radiographs should be acquired as routine imaging work-up in patients with suspected SLJ instability. Radiographic stress views and dynamic fluoroscopy allow accurate diagnosis of dynamic SLJ instability. MR arthrography and CT arthrography are accurate for detecting scapholunate interosseous ligament tears and articular cartilage defects. Ultrasonography and MRI can delineate most extrinsic carpal ligaments, although validated scientific evidence on accurate differentiation between partially or completely torn or incompetent ligaments is not available. CONCLUSIONS: Delphi-based agreements suggest that standardized radiographs, radiographic stress views, dynamic fluoroscopy, MR arthrography and CT arthrography are the most useful and accurate imaging techniques for the work-up of SLJ instability. KEY POINTS: • Dorsopalmar and lateral wrist radiographs remain the basic imaging modality for routine imaging work-up in patients with suspected scapholunate joint instability. • Radiographic stress views and dynamic fluoroscopy of the wrist allow accurate diagnosis of dynamic scapholunate joint instability. • Wrist MR arthrography and CT arthrography are accurate for determination of scapholunate interosseous ligament tears and cartilage defects.


Asunto(s)
Inestabilidad de la Articulación , Traumatismos de la Muñeca , Artrografía , Consenso , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Ligamentos Articulares/diagnóstico por imagen , Traumatismos de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca
7.
Semin Musculoskelet Radiol ; 25(2): 191-202, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34082446

RESUMEN

The pathoanatomy of carpal instability is multifactorial and usually complex. A thorough medical history and clinical examination are essential, as well as profound knowledge of the specific instability patterns. The stability of the wrist is ensured by the carpal joint surfaces, by intact intra-articular (particularly the scapholunate interosseous ligament) and intracapsular ligaments, and by crossing extensor and flexor tendons, the latter making the proximal carpal row an "intercalated segment." An important classification feature is the distinction between dissociative and nondissociative forms of carpal instability. Among others, scapholunate dissociation, lunotriquetral dissociation, midcarpal instability, and ulnar translocation are the most common entities. Early forms of instability are considered dynamic. In the natural course, static instability of the wrist and osteoarthritis will develop. This review focuses on the pathoanatomical fundamentals of the various forms of carpal instability.


Asunto(s)
Huesos del Carpo , Inestabilidad de la Articulación , Huesos del Carpo/diagnóstico por imagen , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Ligamentos Articulares/diagnóstico por imagen , Tendones , Articulación de la Muñeca/diagnóstico por imagen
8.
Semin Musculoskelet Radiol ; 25(2): 304-310, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34374065

RESUMEN

Beyond clinical examination, the various forms of carpal instability are assessed with radiologic methods and arthroscopy. For this purpose, the imaging demand for spatial and contrast resolution is particularly high because of the small ligamentous structures involved. The entities of carpal instability are classified into degrees of severity. Early (dynamic) forms of instability can either be indirectly detected with X-ray stress views and cineradiography or by direct visualization of ruptured ligaments in high-resolution magnetic resonance (MR) imaging and MR or computed tomography (CT) arthrography, with the latter the standard of reference in imaging. Advanced (static) forms of carpal instability are sufficiently well detected on radiographs; visualization of early carpal osteoarthritis is superior on CT. To prevent disability of the hand, the radiologist has to provide an early and precise diagnosis. This case-based review highlights the imaging procedures suitable for detection and classification of carpal instability.


Asunto(s)
Inestabilidad de la Articulación , Articulación de la Muñeca , Artrografía , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Ligamentos Articulares/diagnóstico por imagen , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Articulación de la Muñeca/diagnóstico por imagen
9.
Semin Musculoskelet Radiol ; 25(2): 294-303, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34374064

RESUMEN

Osteoarthritis (OA) is a degenerative disease that can manifest in any synovial joint under certain conditions. It leads to destruction of articular cartilage and adjacent bone, as well as formation of osteophytes at the edges of afflicted joint surfaces. Regarding the wrist, typical degenerative arthritis affects particular joints at a specific patient age, due to asymmetric load distribution and repetitive microtrauma. However, in the presence of instability or systemic diseases, early-onset degeneration can also impair the range of motion and grip strength in younger patients. Although advanced stages of OA display characteristic signs in radiography, the detection of early manifestations frequently requires computed tomography or magnetic resonance imaging (in some cases with additional arthrography). If a wrist becomes unstable, timely diagnosis and precise treatment are essential to prevent rapid disease progression. Therefore, close collaboration between radiologists and hand surgeons is obligatory to preserve the carpal function of patients.


Asunto(s)
Osteoartritis , Radiología , Humanos , Osteoartritis/diagnóstico por imagen , Osteoartritis/terapia , Radiografía , Muñeca , Articulación de la Muñeca/diagnóstico por imagen
10.
Skeletal Radiol ; 50(9): 1909-1913, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33712879

RESUMEN

Hydroxyapatite deposition disease (HADD) is a mostly uniarticular, self-limiting condition caused by deposition of hydroxyapatite (HA) crystals in tendons or in the peritendinous soft tissues. Commonly, the glenohumeral joint is affected. More rarely, the HA depot can be cause of a carpal tunnel syndrome due to an acute inflammatory reaction and space-occupying soft tissue oedema. We report a case of acute HA depot located at the volar site of the right wrist with affection of the deep flexor tendons and intraosseous migration into the lunate bone in a 50-year-old female. There are two main goals of this case report: First, to remind the diagnosis of HADD as a cause of wrist pain and also of carpal tunnel syndrome, as this entity being often misdiagnosed clinically, and second, to report a rare case of intraosseous migration of HA crystals into the lunate bone.


Asunto(s)
Síndrome del Túnel Carpiano , Hueso Semilunar , Femenino , Humanos , Hidroxiapatitas , Hueso Semilunar/diagnóstico por imagen , Hueso Semilunar/cirugía , Persona de Mediana Edad , Tendones , Muñeca , Articulación de la Muñeca/diagnóstico por imagen
11.
Unfallchirurg ; 124(1): 59-73, 2021 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-33351156

RESUMEN

With the exception of the relatively frequent fractures of the scaphoid bone, isolated fractures of individual carpal bones are rare. Because these injuries are uncommon and because of the complex anatomy and function of the carpus, treatment of carpal bone fractures can be challenging. Carpal bone fractures generally occur in young, sports active and professional patients, can be easily overlooked in plain radiographs and are frequently associated with ligamentous instability, neurovascular injuries and tendon lesions. Small posttraumatic alterations of the precisely aligned carpal structure can cause chronic pain and functional impairment. Therefore, if a wrist fracture is suspected a thorough clinical examination and appropriate differentiated imaging is always necessary, at the end of which a fracture can be excluded or an appropriate conservative or surgical treatment is initiated, with the aim of restoration of carpal anatomy and function.


Asunto(s)
Huesos del Carpo , Fracturas Óseas , Hueso Escafoides , Traumatismos de la Muñeca , Huesos del Carpo/diagnóstico por imagen , Huesos del Carpo/cirugía , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Humanos , Radiografía , Hueso Escafoides/diagnóstico por imagen , Hueso Escafoides/cirugía , Traumatismos de la Muñeca/diagnóstico por imagen , Traumatismos de la Muñeca/cirugía , Articulación de la Muñeca
12.
AJR Am J Roentgenol ; 214(2): 422-427, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31799871

RESUMEN

OBJECTIVE. The purpose of this study was to assess image quality and radiation dose of a novel twin robotic x-ray system's 3D cone-beam CT (CBCT) function for the depiction of cadaveric wrists. MATERIALS AND METHODS. Sixteen cadaveric wrists were scanned using dedicated low-dose and standard-dose CBCT protocols as well as clinical MDCT for comparison. Three readers assessed overall image quality, noise, and artifacts in bone and soft tissue on 5-point Likert scales. For radiation dose analysis, volume CT dose indexes (CTDIvol) were compared. RESULTS. Overall image quality of most studies was very good or excellent in MDCT (for readers 1, 2, and 3: 100%, 100%, and 88%, respectively), standard-dose CBCT (100%, 100%, and 94%), and low dose CBCT (100%, 94%, and 88%) with two readers favoring standard-dose CBCT over MDCT image quality (readers 1 and 2; p ≤ 0.046). In soft tissue, standard-dose (readers 1, 2, and 3; p ≤ 0.021) and low-dose (all p ≤ 0.001) CBCT images had more noise than MDCT in all cases. Standard-dose (all p ≤ 0.003) and low-dose (all p < 0.001) CBCT images also displayed more artifacts. In osseous tissue, one reader observed more noise (p < 0.001) and artifacts (p = 0.020) for low-dose CBCT than for MDCT, whereas no difference was found between standard-dose CBCT and MDCT. Mean CTDIvol was significantly lower for standard-dose (5.2 ± 0.6 mGy; p < 0.001) and low-dose CBCT (1.8 ± 0.2 mGy; p < 0.001) than for clinical MDCT without automatic dose modulation (15.0 ± 0.0 mGy). CONCLUSION. The tested CBCT function delivers suitable image quality for clinical wrist imaging at significantly lower radiation levels than conventional MDCT. In combination with comfortable positioning options and the ability to perform additional radiographic and fluoroscopic examinations, the twin robotic x-ray system may hold the potential to be a one-stop shop device for trauma-associated wrist imaging.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Imagenología Tridimensional/métodos , Dosis de Radiación , Robótica , Articulación de la Muñeca/diagnóstico por imagen , Artefactos , Cadáver , Humanos , Posicionamiento del Paciente
13.
BMC Musculoskelet Disord ; 21(1): 286, 2020 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-32381000

RESUMEN

BACKGROUND: Triangular fibrocartilage complex (TFCC) lesions commonly cause ulnar-sided wrist pain and instability of the distal radioulnar joint. Due to its triangular shape, discontinuity of the TFCC is oftentimes difficult to visualize in radiological standard planes. Radial multiplanar reconstructions (MPR) may have the potential to simplify diagnosis in CT wrist arthrography. The objective of this study was to assess diagnostic advantages provided by radial MPR over standard planes for TFCC lesions in CT arthrography. METHODS: One hundred six patients (49 women, 57 men; mean age 44.2 ± 15.8 years) underwent CT imaging after wrist arthrography. Two radiologists (R1, R2) retrospectively analyzed three randomized datasets for each CT arthrography. One set contained axial, coronal and sagittal planes (MPRStandard), while the other two included an additional radial reconstruction with the rotating center either atop the ulnar styloid (MPRStyloid) or in the ulnar fovea (MPRFovea). Readers evaluated TFCC differentiability and condition. Suspected lesions were categorized using Palmer's and Atzei's classification and diagnostic confidence was stated on a five-point Likert scale. RESULTS: Compared to standard planes, differentiability of the superficial and deep TFCC layer was superior in radial reconstructions (R1/R2; MPRFovea: p < 0.001; MPRStyloid: p ≤ 0.007). Palmer and Atzei lesions were present in 86.8% (92/106) and 52.8% (56/106) of patients, respectively. Specificity, sensitivity and accuracy for central Palmer lesions did not differ in radial and standard MPR. For peripheral Atzei lesions, sensitivity (MPRStandard 78.6%/80.4%, MPRStyloid 94.6%/94.6%, MPRFovea 91.1%/89.3%) and accuracy (MPRStandard 86.8%/86.8%, MPRStyloid 96.2%/96.2%, MPRFovea 94.3%/93.4%) improved with additional styloid-centered (p = 0.004/0.008) and fovea-centered (p = 0.039/0.125) reconstructions. No substantial difference was observed between both radial MPR (p = 0.688/0.250). Interrater agreement was almost perfect for each dataset (κStandard = 0.876, κStyloid = 0.894, κFovea = 0.949). Diagnostic confidence increased with addition of either radial MPR (p < 0.001). CONCLUSIONS: Ancillary radial planes improve accuracy and diagnostic confidence for detection of peripheral TFCC lesions in CT arthrography of the wrist.


Asunto(s)
Artrografía/métodos , Tomografía Computarizada por Rayos X/métodos , Fibrocartílago Triangular/diagnóstico por imagen , Fibrocartílago Triangular/lesiones , Traumatismos de la Muñeca/diagnóstico por imagen , Adulto , Exactitud de los Datos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radio (Anatomía)/diagnóstico por imagen , Estudios Retrospectivos , Cúbito/diagnóstico por imagen , Muñeca/diagnóstico por imagen , Articulación de la Muñeca/diagnóstico por imagen
14.
Semin Musculoskelet Radiol ; 28(3): 356-358, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38768600
15.
Semin Musculoskelet Radiol ; 23(5): 523-533, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31556087

RESUMEN

Regarding the upper extremity, osteonecrosis can relate to the humeral head and to any carpal bone, most commonly the lunate (Kienböck's disease), scaphoid (Preiser's disease and nonunion), and capitate bone (osteonecrosis of the capitate head). In children and adolescents, osteochondrosis is an important differential diagnosis at the epiphyses. Appropriate imaging of osteonecrosis depends on knowledge about blood supply, biomechanical load, and bone repair mechanisms. Contrast-enhanced MRI (ceMRI) enables the differentiation of up to three mostly band-shaped zones: necrotic tissue (proximal), hypervascular repair tissue (intermediate), and viable bone (distal). To distinguish between necrotic and repair zones, intravenous gadolinium is recommended in MRI. Osteosclerosis and insufficiency fractures in early and intermediate stages as well as osteoarthritis in advanced stages are best depicted using high-resolution CT (HRCT). The combination of HRCT and ceMRI allows for exact classification of osteonecrosis regarding morphology and viability.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Osteonecrosis/diagnóstico por imagen , Extremidad Superior/diagnóstico por imagen , Huesos/diagnóstico por imagen , Huesos/patología , Diagnóstico Diferencial , Humanos , Osteonecrosis/patología , Extremidad Superior/patología
16.
Eur Radiol ; 28(8): 3432-3440, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29426987

RESUMEN

OBJECTIVE: To compare image quality, observer confidence, radiation exposure in the standard-dose (SD-CCTA) and low-dose (LD-CCTA) protocols of coronary CT angiography (CCTA) in patients with atrial fibrillation (AF). MATERIAL AND METHODS: CCTA was performed in 303 patients using a CT scanner with 16-cm coverage (111 scans during sinus rhythm (SR); 192 during AF). LD-CCTA was used in 218 patients; SD-CCTA in 85 patients suspected of having coronary artery disease (CAD). Image quality and observer confidence were evaluated on 5-point scales. Radiation doses were recorded. RESULTS: Image quality was superior in the SD-CCTA compared to the LD-CCTA (SR 1.45±0.40; AF 1.72±0.46; vs. SR 1.83±0.48; AF 1.92±0.50; p < 0.001). Observers were more confident with SD-CCTA than with LD-CCTA (SR 1.38±0.33; AF 1.61±0.43; vs. SR 1.70±0.45; AF 1.82±0.50; p < 0.001). Radiation doses in AF were significantly higher than in the SR (LD-CCTA, 1.68±0.71 mSv; SD-CCTA, 3.72±1.95 mSv; vs. LD-CCTA, 1.3 ±0.52 mSv; SD-CCTA, 2.67±1.47 mSv; p < 0.001). CONCLUSION: Using a low-dose protocol in AF, radiation exposure can be decreased by 50 % at the expense of 20 % impaired image quality. A low-dose CCTA protocol can be considered in young patients, whereas the standard-dose protocol is recommended for older patients and those suspected of having CAD. KEY POINTS: • Whole-heart CT allows visualization of the coronary arteries in atrial fibrillation. • Low-dose CT decreases radiation exposure by 50%, image quality by 20%. • Standard-dose CT seems advantageous when concomitant coronary artery disease is suspected.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Angiografía por Tomografía Computarizada/instrumentación , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/instrumentación , Angiografía Coronaria/métodos , Dosis de Radiación , Femenino , Corazón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Exposición a la Radiación
17.
Ann Plast Surg ; 76(1): 40-5, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26010354

RESUMEN

BACKGROUND: Hypothenar hammer syndrome is a rare vascular lesion of the distal ulnar artery in Guyon tunnel caused by acute or repetitive blunt trauma to the hypothenar eminence. Described treatment options vary greatly, from nonoperative management treatments to surgical interventions. The aim of this study was to evaluate the long-term outcomes of patients after surgical reconstruction of the ulnar artery. METHODS: In this retrospective study, the results of 12 patients treated for hypothenar hammer syndrome were evaluated. Preoperative and postoperative examinations of the hand were recorded. Function impairment was assessed with the "Disabilites of the Arm, Shoulder and Hand" questionnaire. Comparisons were also made based on ulnar artery patency versus occlusion. All patients were evaluated for ulnar artery patency as determined by Allen's test and magnetic resonance angiography. RESULTS: All patients were men with an average age of 42.8 years. In 3 patients, a direct end-to-end anastomosis of the ulnar artery was performed, and 9 patients received a reconstruction with a reverse interpositional vein graft. Nine vascular reconstructions remained patent after a mean follow-up period of 56.9 months. These patients had a complete or at least partial relief of their pain, dysesthesia, and cold intolerance compared with preoperatively. Patients with reoccluded ulnar arteries were statistically significant younger (P = 0.036) than patients with patent ulnar artery. They also had a higher pain level (P = 0.009) and a longer follow-up period (P = 0.036) than those with patent reconstruction. There was a trend for higher functional impairment in patients with reoccluded ulnar artery (P = 0.100). Smoking habits showed no influence on ulnar artery patency. CONCLUSIONS: For patients with symptomatic hypothenar hammer syndrome and failed nonoperative treatment, surgical intervention is a good option. After more than 4.5 years after surgery 9 of 12 vascular reconstructions remained patent (75% patency rate), ensuring an immediate and long-term improvement of symptoms.


Asunto(s)
Arteriopatías Oclusivas/cirugía , Mano/irrigación sanguínea , Arteria Cubital/fisiopatología , Procedimientos Quirúrgicos Vasculares/métodos , Adulto , Arteriopatías Oclusivas/diagnóstico por imagen , Estudios de Cohortes , Estudios de Seguimiento , Humanos , Angiografía por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Radiografía , Enfermedades Raras , Procedimientos de Cirugía Plástica/métodos , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Estadísticas no Paramétricas , Síndrome , Resultado del Tratamiento , Arteria Cubital/cirugía , Grado de Desobstrucción Vascular/fisiología
18.
J Cardiovasc Electrophysiol ; 26(10): 1063-8, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26076115

RESUMEN

BACKGROUND: Single-shot ablation devices for pulmonary vein isolation (PVI) in patients with symptomatic atrial fibrillation (AF) have been increasingly used in clinical practice. OBJECTIVE: A novel mapping-system integrated irrigated multipolar circular ablation catheter (nMARQ) has been introduced for PVI but data on larger patient cohorts on acute safety and efficacy are lacking. METHODS: A total of 145 consecutive patients undergoing AF ablation treated with the nMARQ underwent endoscopic evaluation of esophageal thermal damage (EDEL) and brain MRI for detection of silent cerebral events (SCE). During the course of our experience different modifications of the ablation strategy, including energy delivery at the left atrial posterior wall, were evaluated. RESULTS: Effective PVI was achieved in 99% of all PVs during a mean procedure-duration of 115 (±36) minutes and ablation-duration of 18 (±8) minutes. Acute major complications occurred in 3 patients (2.1%) and asymptomatic complications like SCE in 26% and EDEL in 21%. There was a significant reduction in EDEL when not using a thermal esophageal probe (0% vs. 28%, P < 0.0001). Ablation under oral anticoagulation led to lower SCE incidences compared to interrupted anticoagulation regimen (15% vs. 31%, P = 0.7). Out of 65 patients with completed 12-month follow-up, 43 (66%) were in stable sinus rhythm. CONCLUSIONS: PVI using the nMARQ is safe and effective in patients with symptomatic AF. Not using an esophageal temperature probe during ablation has relevantly reduced the incidence of EDEL. Ablations under continued oral anticoagulation have reduced incidence of SCE. Further studies on long-term efficacy are needed.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Ablación por Catéter/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Irrigación Terapéutica/estadística & datos numéricos , Enfermedad Aguda , Fibrilación Atrial/diagnóstico , Mapeo del Potencial de Superficie Corporal/instrumentación , Mapeo del Potencial de Superficie Corporal/métodos , Mapeo del Potencial de Superficie Corporal/estadística & datos numéricos , Ablación por Catéter/métodos , Estudios de Cohortes , Comorbilidad , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Venas Pulmonares/cirugía , Factores de Riesgo , Irrigación Terapéutica/instrumentación , Irrigación Terapéutica/métodos , Resultado del Tratamiento
19.
J Cardiovasc Electrophysiol ; 26(4): 455-463, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25556518

RESUMEN

Brain magnetic resonance imaging (MRI) has identified a high incidence of cerebral ischemia in asymptomatic patients after atrial fibrillation (AF) ablation (silent). Detection of cerebral ischemic events on MRI is based on acute hyperintense lesions on diffusion-weighted imaging. In the literature, the incidence is related to specifications of MRI and depends on the definition applied. In comparative studies, silent cerebral events (SCE, diffusion-weighted MRI [DWI] positive only) appear to be approximately 3 times more common compared to using a definition of silent cerebral lesions (SCL; without fluid attenuated inverse recovery sequence [FLAIR] positivity). Whereas the FLAIR sequence may turn positive within days after the ischemic event, SCE definition is highly sensitive for early phases of ischemic brain damage. SCE/SCL appear to represent cerebral ischemic infarcts and determine the "embolic fingerprint" of a specific ablation technology and strategy used. The optimum time point for detecting SCE is early after AF ablation (24-72 hours), whereas detection of SCL can only be performed within the first 2-7 days (due to delay of FLAIR positivity). Different technology-, procedure-, and patient-related parameters have been identified to play a role in the multifactorial genesis of SCE/SCL. In recent years, evidence has been gathered that there may be differences of SCE/SCL rates depending upon the ablation technology used, but small patient numbers and a large number of potential confounders hamper all studies. As major findings of recent studies, mode of periprocedural and intraprocedural anticoagulation has been identified as a major predictor for incidences of SCE/SCL. Whereas procedural characteristics related to higher SCE/SCL-rates may be modified, unchangeable patient-related factors should be taken into account for future individualized risk assessment. Novel ablation devices introduced into the market should be tested for their potential embolic fingerprint and refinements of ablation procedures to reduce their embolic potential should be prompted. The knowledge of "best practice" in terms of low SCE/SCL rates has prompted changes in work-flow, which have been implemented into ablation procedures using novel ablation devices. So far, no study has linked SCE/SCL to neuropsychological decline and the low number of AF-ablation-associated events needs to be weighted against the multitude of preexisting asymptomatic MRI-detected brain lesions related to the course of AF itself. Future studies are needed to evaluate if more white matter hyperintensities due to AF may be prevented by AF ablation (producing only a small number of SCE/SCL).


Asunto(s)
Fibrilación Atrial/cirugía , Isquemia Encefálica/etiología , Ablación por Catéter/efectos adversos , Embolia Intracraneal/etiología , Enfermedades Asintomáticas , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Isquemia Encefálica/diagnóstico , Consenso , Imagen de Difusión por Resonancia Magnética , Humanos , Embolia Intracraneal/diagnóstico , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
20.
J Cardiovasc Electrophysiol ; 25(4): 339-345, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24237612

RESUMEN

INTRODUCTION: "Single shot" ablation devices to treat symptomatic atrial fibrillation have been engineered over the last years. Safety and efficacy also includes subclinical complications only detected with esophageal endoscopy or cerebral MRI in asymptomatic patients. We studied the acute efficacy and safety profile of a novel multipolar irrigated RF ablation catheter (nMARQ™). METHODS AND RESULTS: Forty-three patients underwent pulmonary vein isolation (PVI) using the novel ablation device. Patient baseline and procedural characteristics were documented. Efficacy of PVI was identified using only the nMARQ™ catheter. All patients underwent postablation endoscopic evaluation of the esophagus to document thermal damage and cerebral MRI (diffusion weight imaging, attenuated diffusion coefficient-map) to document incidence and number of silent cerebral lesions (SCL). Effective PVI was achieved in 98% of targeted PVs in a mean procedure time of 133 minutes. A mean of 4.8, 60-second RF applications, per PV was needed for effective PVI. No clinical procedure-associated complications were noted. Esophageal temperature increase >40.5 °C was noted in 22 (51%) patients and 14 of these had thermal esophageal lesions on endoscopic evaluation. A total of 26 SCLs were noted in 14 patients (33%; 1.9/patient; mean diameter of 2.3 mm, 88% of lesions were ≤3 mm). CONCLUSIONS: PVI using the novel irrigated RF multipolar ablation device (nMARQ™) appears to be acutely effective. No clinical complications were identified. A high incidence of SCL (33%) and thermal esophageal lesions (33%) bears caution and further studies on long-term efficacy and safety are needed.


Asunto(s)
Ablación por Catéter/instrumentación , Venas Pulmonares/cirugía , Anciano , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/cirugía , Lesiones Encefálicas/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Recurrencia , Seguridad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA