J Appl Clin Med Phys ; 24(5): e13962, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36942718

RESUMEN

The well-referenced structural shielding design NCRP Report No. 147 uses workload information based on self-reported film-screen data from the AAPM Task Group 9 survey. The aim of this study was to assess the clinical workload distributions of modern digital radiography (DR) systems in general hospital and pediatric-only practices. A retrospective analysis of DR imaging data on four radiographic systems in a hospital practice and two radiographic systems in a pediatric practice, through a custom clinical DICOM header analytics program. A total of 203, 294 exposures from the general hospital practice and 25,415 from the pediatric practice from 2019 and 2021 were included. Values for kVp, mAs, and detector type (wall bucky, table bucky, or free detector) were extracted. For each exam, mAs was accumulated in a kVp histogram with bins 5 kVp wide and further parsed by detector type. Total workload was calculated by summing all exposures, then normalized by the number of patients. The median (25th and 75th percentile) workload in the hospital practice was 0.43 (0.22, 1.13) mA-min per patient, while the average was 1.36 ± 3.08. Pediatric data yielded a median (25th and 75th percentile) of 0.10 (0.05, 0.23) and an average of 0.29 ± 0.69 mA-min per patient. Mean number of patients per week was 230 adult and 57 pediatric. Hospital workload data is approximately 44% less than the NCRP Report No. 147 value.


Asunto(s)
Intensificación de Imagen Radiográfica , Carga de Trabajo , Adulto , Humanos , Niño , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos , Hospitales
2.
Clin Gastroenterol Hepatol ; 20(3): 709-711.e2, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-33813073

RESUMEN

Schatzki rings (SRs) are a well-known cause of intermittent solid-food dysphagia.1 Although some patients sustain improvement after 1 endoscopic dilation, others require repeated dilations for recurrent symptoms.2-4 SRs are believed to be distinct from strictures caused by gastroesophageal reflux disease. SRs are sharply localized lesions with clearly defined margins, whereas peptic strictures have a more gradual transition between normal and abnormal esophagus to produce a funnel-shaped narrowing.5,6 Consequently, it has been assumed that repeat dilation is less common in SRs dissimilar from medically untreated peptic strictures. The study aim was to identify clinical and radiologic predictors for repeated esophageal dilations in patients with SRs and to assess if peptic stricture-like characteristics of rings correspond to need for repeat dilation.


Asunto(s)
Enfermedades del Esófago , Estenosis Esofágica , Constricción Patológica/complicaciones , Dilatación/efectos adversos , Estenosis Esofágica/diagnóstico , Estenosis Esofágica/etiología , Humanos
3.
J Appl Clin Med Phys ; 23(12): e13812, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36321326

RESUMEN

There is a lack of understanding in the performance of flexible noise control (FNC) processing, which is used in digital radiography on a scanner vendor and has four parameters each involving multiple options. The aim of this study was to investigate the impact of FNC on portable chest imaging. An anthropomorphic chest phantom was imaged using a clinical chest program with 85 kV and five radiation dose levels at 40″ source-to-image distance with software-based scatter reduction method. All images were processed without and with FNC. Noise analysis was performed in two regions of interest (ROI) on subtracted noise-only images, and line profiles were generated through a lung-rib interface. In addition, noise power spectra (NPS) analysis was performed in solid water phantoms of 10 and 20 cm thicknesses, using the same acquisition program and a range of dose levels. Last, feedback on retrospectively deidentified, reprocessed, and randomized clinical images from 20 portable chest exams was gathered from two thoracic radiologists. Noise reduction performances of FNC were demonstrated, with the level depending on specific FNC parameters, dose levels, ROI placement, and phantom sizes. Higher frequency textural patterns were revealed through the NPS analysis, which varied based on FNC parameters, dose levels, and phantom sizes. Overall, the vendor default parameter FGA0.5 yielded the highest noise reduction and textural artifacts. Radiologist feedback showed consistent preference of no FNC due to the presence of textural artifacts in the FNC-processed images. An algorithm improvement to avoid introducing artifacts would be desired.


Asunto(s)
Intensificación de Imagen Radiográfica , Radiografía Torácica , Humanos , Radiografía Torácica/métodos , Estudios Retrospectivos , Radiografía , Intensificación de Imagen Radiográfica/métodos , Pulmón/diagnóstico por imagen , Dosis de Radiación , Fantasmas de Imagen
4.
J Appl Clin Med Phys ; 22(6): 11-15, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34018313

RESUMEN

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: (1) Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. (2) Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances.


Asunto(s)
Física Sanitaria , Oncología por Radiación , Humanos , Sociedades , Estados Unidos
5.
J Appl Clin Med Phys ; 22(1): 343-349, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33395503

RESUMEN

PURPOSE: An increasing number of implantable or external devices can impact whether patients can receive radiological imaging examinations. This study examines and tests the Neulasta (pegfilgrastim) Onpro on-body injector in multiple imaging environments. METHODS: The injector was analyzed for four imaging modalities with testing protocols and strategies developed for each modality. In x-ray and computed tomography (CT), scans with much higher exposure than clinical protocols were performed with the device attached to an anthropomorphic phantom. The device was monitored until the completion of drug delivery. For magnetic resonance imaging (MRI), the device was assessed using a hand-held magnet and underwent the magnetically induced displacement testing in a 1.5T clinical MRI scanner room. For ultrasound, magnetic field changes were measured around an ultrasound scanner system with three transducers. RESULTS: For x-ray and CT no sign of device error was identified during or after the high radiation exposure scans. Drug delivery was completed at expected timing with expected volume. For MRI the device showed significant attractive force towards the hand-held magnet and a 50-degree deflection angle at 50 cm from the opening of the scanner bore. No further assessment from the gradient or radiofrequency field was deemed necessary. For ultrasound the maximum magnetic field change from baseline was measured to be +11.7 µT in comparison to +74.2 µT at 4 inches from a working microwave. CONCLUSIONS: No device performance issue was identified under the extreme test conditions in x-ray or CT. The device was found to be MR Unsafe. Magnetic field changes around an ultrasound system met the limitation set by manufacture. Patient ultrasound scanning is considered safe as long as the transducers do not inadvertently loosen the device.


Asunto(s)
Imagen por Resonancia Magnética , Polietilenglicoles , Filgrastim , Humanos , Fantasmas de Imagen
6.
J Appl Clin Med Phys ; 21(7): 11-15, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31800151

RESUMEN

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances. Approved by AAPM's Executive Committee May 28, 2019.


Asunto(s)
Física Sanitaria , Oncología por Radiación , Humanos , Sociedades , Estados Unidos
7.
J Appl Clin Med Phys ; 20(2): 136-145, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30677233

RESUMEN

Careful protocol selection is required during intraoperative three-dimensional (3D) imaging for spine surgery to manage patient radiation dose and achieve clinical image quality. Radiation dose and image quality of a Medtronic O-arm commonly used during spine surgery, and a Philips hybrid operating room equipped with XperCT C-arm 3D cone-beam CT (hCBCT) are compared. The mobile O-arm (mCBCT) offers three different radiation dose settings (low, standard, and high), for four different patient sizes (small, medium, large, and extra large). The patient's radiation dose rate is constant during the entire 3D scan. In contrast, C-CBCT spine imaging uses three different field of views (27, 37, and 48 cm) using automatic exposure control (AEC) that modulates the patient's radiation dose rate during the 3D scan based on changing patient thickness. hCBCT uses additional x-ray beam filtration. Small, medium, and large trunk phantoms designed to mimic spine and soft tissue were imaged to assess radiation dose and image quality of the two systems. The estimated measured "patient" dose for the small, medium, and large phantoms imaged by the mCBCT considering all the dose settings ranged from 9.4-27.6 mGy, 8.9-33.3 mGy, and 13.8-40.6 mGy, respectively. The "patient" dose values for the same phantoms imaged with hCBCT were 2.8-4.6 mGy, 5.7-10.0 mGy, and 11.0-15.2 mGy. The CNR for the small, medium, and large phantoms was 2.9 to 3.7, 2.0 to 3.0, and 2.5 to 2.6 times higher with the hCBCT system, respectively. Hounsfield unit accuracy, noise, and uniformity of hCBCT exceeded the performance of the mCBCT; spatial resolution was comparable. Added x-ray beam filtration and AEC capability achieved clinical image quality for intraoperative spine surgery at reduced radiation dose to the patient in comparison to a reference O-arm system without these capabilities.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Fantasmas de Imagen , Radiocirugia/métodos , Neoplasias de la Columna Vertebral/cirugía , Cirugía Asistida por Computador/métodos , Humanos , Cuidados Intraoperatorios , Órganos en Riesgo/efectos de la radiación , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
8.
Radiographics ; 38(3): 833-846, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29676963

RESUMEN

Visual familiarity with the variety of digital radiographic artifacts is needed to identify, resolve, or prevent image artifacts from creating issues with patient imaging. Because the mechanism for image creation is different between flat-panel detectors and computed radiography, the causes and appearances of some artifacts can be unique to these different modalities. Examples are provided of artifacts that were found on clinical images or during quality control testing with flat-panel detectors. The examples are meant to serve as learning tools for future identification and troubleshooting of artifacts and as a reminder for steps that can be taken for prevention. The examples of artifacts provided are classified according to their causal connection in the imaging chain, including an equipment defect as a result of an accident or mishandling, debris or gain calibration flaws, a problematic acquisition technique, signal transmission failures, and image processing issues. Specific artifacts include those that are due to flat-panel detector drops, backscatter, debris in the x-ray field during calibration, detector saturation or underexposure, or collimation detection errors, as well as a variety of artifacts that are processing induced. ©RSNA, 2018.


Asunto(s)
Artefactos , Intensificación de Imagen Radiográfica/métodos , Diagnóstico Diferencial , Humanos , Intensificación de Imagen Radiográfica/instrumentación
9.
Pain Med ; 18(4): 651-654, 2017 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28586445

RESUMEN

Objective: To assess the relative radiographic conspicuity of gadolinium-based contrast agents (GBCAs) that may be used in spinal injection procedures when iodine-based contrast agents are contraindicated. Methods: Eight GBCAs and three iodinated agents of varying iodine concentrations were radiographed under conditions representative of lumbar spinal injections at four kilovoltage peak (kVp) values. Radiographic contrast of each agent was measured as the percent pixel value difference with respect to background. Results: Gadobutrol (Gadovist, 1 mM/mL) had the highest radiographic contrast among the gadolinium agents tested. Measured radiographic contrast correlated with the molar concentration of gadolinium. Gadobutrol radiographic contrast lies between the contrast of iohexol concentrations of 240 and 140 mgI/mL. All agents have decreasing contrast as kVp increases, but GBCAs decrease less than iodine-based agents. Conclusions: Gadobutrol is the GBCA with the greatest conspicuity for use in spinal injection procedures. It also has the highest molar concentration of gadolinium, and potential neural toxicity from intrathecal delivery must be considered.


Asunto(s)
Gadolinio/administración & dosificación , Aumento de la Imagen/métodos , Inyecciones Espinales/métodos , Yodo/administración & dosificación , Imagen por Resonancia Magnética Intervencional/métodos , Médula Espinal/diagnóstico por imagen , Medios de Contraste/administración & dosificación , Medios de Contraste/química , Gadolinio/química , Gadolinio/farmacología , Humanos , Yodo/farmacología , Imagen por Resonancia Magnética Intervencional/instrumentación , Manejo del Dolor , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Médula Espinal/efectos de los fármacos , Resultado del Tratamiento
11.
J Pediatr Orthop ; 37(3): 171-177, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27453221

RESUMEN

BACKGROUND: Intraoperative C-arm fluoroscopy and low-dose O-arm are both reasonable means to assist in screw placement for idiopathic scoliosis surgery. Both using pediatric low-dose O-arm settings and minimizing the number of radiographs during C-arm fluoroscopy guidance decrease patient radiation exposure and its deleterious biological effect that may be associated with cancer risk. We hypothesized that the radiation dose for C-arm-guided fluoroscopy is no less than low-dose O-arm scanning for placement of pedicle screws. METHODS: A multicenter matched-control cohort study of 28 patients in total was conducted. Fourteen patients who underwent O-arm-guided pedicle screw insertion for spinal fusion surgery in 1 institution were matched to another 14 patients who underwent C-arm fluoroscopy guidance in the other institution in terms of the age of surgery, body weight, and number of imaged spine levels. The total effective dose was compared. A low-dose pediatric protocol was used for all O-arm scans with an effective dose of 0.65 mSv per scan. The effective dose of C-arm fluoroscopy was determined using anthropomorphic phantoms that represented the thoracic and lumbar spine in anteroposterior and lateral views, respectively. The clinical outcome and complications of all patients were documented. RESULTS: The mean total effective dose for the O-arm group was approximately 4 times higher than that of the C-arm group (P<0.0001). The effective dose for the C-arm patients had high variability based on fluoroscopy time and did not correlate with the number of imaged spine levels or body weight. The effective dose of 1 low-dose pediatric O-arm scan approximated 85 seconds of the C-arm fluoroscopy time. All patients had satisfactory clinical outcomes without major complications that required returning to the operating room. CONCLUSIONS: Radiation exposure required for O-arm scans can be higher than that required for C-arm fluoroscopy, but it depends on fluoroscopy time. Inclusion of more medical centers and surgeons will better account for the variability of C-arm dose due to distinct patient characteristics, surgeon's preference, and individual institution's protocol. LEVEL OF EVIDENCE: Level III-case-control study.


Asunto(s)
Fluoroscopía/métodos , Tornillos Pediculares , Exposición a la Radiación , Escoliosis/cirugía , Fusión Vertebral/métodos , Adolescente , Estudios de Casos y Controles , Niño , Estudios de Cohortes , Femenino , Fluoroscopía/efectos adversos , Humanos , Vértebras Lumbares/cirugía , Masculino , Dosis de Radiación , Exposición a la Radiación/normas , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/métodos
12.
J Radiol Prot ; 37(1): 43-58, 2017 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-27941226

RESUMEN

Physicians performing x-ray guided interventional procedures have a keen interest in radiation safety. Radiation dose to tissues and organs of the head and neck are of particular interest because they are not routinely protected by wearable radiation safety devices. This study was conducted to facilitate estimation of radiation dose to tissues of the head and neck of interventional physicians based on the dose recorded by a personal dosimeter worn on the left collar. Scatter beam qualities maximum energy and HVL were measured for 40 scatter beams emitting from an anthropomorphic patient phantom. Variables of the scatter beams included scatter angle (35° and 90°), primary beam peak tube potential (60, 80, 100, and 120 kVp), and 5 Cu spectral filter thicknesses (0-0.9 mm). Four reference scatter beam qualities were selected to represent the range of scatter beams realized in a typical practice. A general radiographic x-ray tube was tuned to produce scatter-equivalent radiographic beams and used to simultaneously expose the head and neck of an anthropomorphic operator phantom and radiochromic film. The geometric relationship between the x-ray source of the scatter-equivalent beams and the operator phantom was set to mimic that between a patient and physician performing an invasive cardiovascular procedure. Dose to the exterior surface of the operator phantom was measured with both 3 × 3 cm2 pieces of film and personal dosimeters positioned at the location of the left collar. All films were scanned with a calibrated flatbed scanner, which converted the film's reflective density to dose. Films from the transverse planes of the operator phantom provided 2D maps of the dose distribution within the phantom. These dose maps were normalized by the dose at the left collar, providing 2D percent of left collar dose (LCD) maps. The percent LCD maps were overlain with bony anatomy CT images of the operator phantom and estimates of percent LCD to the left, right and whole brain, brain stem, lenses of the eyes, and carotid arteries were calculated. Per expectation, results indicated greater percent dose to superficial versus deep tissues and increasing percent dose to deep tissues with increasing scatter-equivalent beam energy and HVL. The results enable estimation of the scatter dose to tissues of the head and neck of interventional physicians based on occupational dose measured by a personal dosimeter worn at the collar outside the protective apron.


Asunto(s)
Enfermedades Cardiovasculares/terapia , Cabeza/efectos de la radiación , Cuello/efectos de la radiación , Exposición Profesional/análisis , Radiografía Intervencional , Radiometría/métodos , Humanos , Fantasmas de Imagen , Dosis de Radiación , Protección Radiológica , Dispersión de Radiación , Rayos X
14.
J Pediatr Orthop ; 36(6): 621-6, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26296221

RESUMEN

BACKGROUND: Intraoperative computed tomography and image-guided navigation improve the accuracy of screw placement. Radiation exposure to the patient remains a primary drawback. The objective of the present study was to compare the total intraoperative radiation dose and assess the resultant image quality for O-arm-assisted pedicle screw insertion, among 3 protocols: default (manufacturer recommended), institutional (reduced dose utilized in our institution), and pediatric (new protocol with lowest dose). METHODS: Thirty-seven consecutive patients under the age of 18 years underwent posterior instrumentation of the spine and underwent an intraoperative O-arm scan. Techniques (kV and mAs) for default and institutional dose settings were manually adjusted based on spinal level and body weight. Pediatric dose techniques were 80 kV/80 mAs with no adjustment for level or weight. The number of scans repeated because of inadequate imaging was assessed, and the mean estimated effective dose between the 3 protocols was compared. RESULTS: Sixty-eight scans were performed in 37 consecutive patients with mean age of 14 years and mean weight of 55 kg. For reference, the effective radiation dose of a chest x-ray is approximately 0.10 mSv. Use of the default protocol resulted in higher mean effective dose per scan of 4.65 mSv, whereas institutional protocol resulted in 2.37 mSv. The pediatric protocol reduced the mean dose to 0.65 mSv. The total effective dose per surgery was: 1.17 mSv (pediatric), 3.83 mSv (institutional), and 12.79 mSv (default) (P<0.0001 each). All scans lead to satisfactory image quality except in 1 patient >100 kg with stainless steel implants. There were no neurological or other implant-related complications. The pediatric protocol resulted in satisfactory image quality with the lowest total radiation dose, only 1/10 of that of the default protocol. CONCLUSIONS: We successfully switched to a pediatric low-dose O-arm protocol in clinical practice, reducing the dose to <1/4 of the mean annual natural background radiation. This may allow use of intraoperative computed tomography and navigation for pedicle screw placement without excessive radiation exposure to young patients. LEVEL OF EVIDENCE: Level III-retrospective comparative study.


Asunto(s)
Procedimientos Ortopédicos , Dosis de Radiación , Columna Vertebral , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X , Adolescente , Protocolos Clínicos , Femenino , Humanos , Cuidados Intraoperatorios/métodos , Masculino , Procedimientos Ortopédicos/efectos adversos , Procedimientos Ortopédicos/métodos , Tornillos Pediculares , Exposición a la Radiación/normas , Estudios Retrospectivos , Ajuste de Riesgo , Columna Vertebral/diagnóstico por imagen , Columna Vertebral/cirugía , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos
15.
J Digit Imaging ; 29(1): 141-7, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26349914

RESUMEN

Thoracic computed tomography (CT) is considered the gold standard for detection lung pathology, yet its efficacy as a screening tool in regards to cost and radiation dose continues to evolve. Chest radiography (CXR) remains a useful and ubiquitous tool for detection and characterization of pulmonary pathology, but reduced sensitivity and specificity compared to CT. This prospective, blinded study compares the sensitivity of digital tomosynthesis (DTS), to that of CT and CXR for the identification and characterization of lung nodules. Ninety-five outpatients received a posteroanterior (PA) and lateral CXR, DTS, and chest CT at one care episode. The CXR and DTS studies were independently interpreted by three thoracic radiologists. The CT studies were used as the gold standard and read by a fourth thoracic radiologist. Nodules were characterized by presence, location, size, and composition. The agreement between observers and the effective radiation dose for each modality was objectively calculated. One hundred forty-five nodules of greatest diameter larger than 4 mm and 215 nodules less than 4 mm were identified by CT. DTS identified significantly more >4 mm nodules than CXR (DTS 32 % vs. CXR 17 %). CXR and DTS showed no significant difference in the ability to identify the smaller nodules or central nodules within 3 cm of the hilum. DTS outperformed CXR in identifying pleural nodules and those nodules located greater than 3 cm from the hilum. Average radiation dose for CXR, DTS, and CT were 0.10, 0.21, and 6.8 mSv, respectively. Thoracic digital tomosynthesis requires significantly less radiation dose than CT and nearly doubles the sensitivity of that of CXR for the identification of lung nodules greater than 4 mm. However, sensitivity and specificity for detection and characterization of lung nodules remains substantially less than CT. The apparent benefits over CXR, low cost, rapid acquisition, and minimal radiation dose of thoracic DTS suggest that it may be a useful procedure. Work-up of a newly diagnosed nodule will likely require CT, given its superior cross-sectional characterization. Further investigation of DTS as a diagnostic, screening, and surveillance tool is warranted.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Pulmón/diagnóstico por imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Método Simple Ciego
16.
AJR Am J Roentgenol ; 205(1): W124-32, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26102410

RESUMEN

OBJECTIVE: Digital slot scanning is a relatively new technology that has been used for imaging of pediatric orthopedic conditions such as scoliosis and leg-length discrepancies. This article will review the clinical applications, advantages, and unique artifacts of this new technology. CONCLUSION: Upright biplanar slot scanners acquire high-resolution radiographs simultaneously in two orthogonal planes with reduced radiation dose. Other advantages include a more physiologic weightbearing imaging position, improved Cobb angle measurements, and 3D modeling.


Asunto(s)
Diferencia de Longitud de las Piernas/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Escoliosis/diagnóstico por imagen , Artefactos , Niño , Humanos , Imagenología Tridimensional , Dosis de Radiación , Soporte de Peso
17.
J Appl Clin Med Phys ; 16(3): 5291, 2015 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-26103491

RESUMEN

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States.The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner.Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized.The following terms are used in the AAPM practice guidelines:Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline.Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances.


Asunto(s)
Física Sanitaria/educación , Física Sanitaria/normas , Oncología por Radiación/educación , Oncología por Radiación/normas , Sociedades Científicas/normas , Enseñanza/normas , Competencia Clínica/normas , Evaluación Educacional/normas , Mentores , Estados Unidos
18.
J Arthroplasty ; 30(9): 1565-8, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25873283

RESUMEN

Fluoroscopic guidance is commonly utilized during direct anterior total hip arthroplasty (DA THA). The purpose of this study was to measure patient and surgeon exposure utilizing this technique. Fifty-one consecutive patients who underwent primary DA THA by a single surgeon were prospectively studied. Fluoroscopic guidance was utilized according to an established protocol. Dose-area product (DAP) (Gy-cm(2)) and fluoroscopy time were recorded for each case. Surgeon exposure was recorded by a dosimeter. The median DAP was 0.716 Gy-cm(2) (range 0.251-1.81). Mean fluoroscopy time was 0.59 minutes. Dosimeter results were 10 mrem for all procedures combined. DAP and fluoroscopy times were comparable to published values for other fluoroscopically guided hip procedures. This information may aid in setting reference dose levels for this procedure.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Fluoroscopía/efectos adversos , Exposición a la Radiación , Cirugía Asistida por Computador/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Exposición Profesional , Estudios Prospectivos , Dosis de Radiación , Reproducibilidad de los Resultados
19.
Pain Med ; 15(8): 1328-33, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24961152

RESUMEN

OBJECTIVE: This study seeks to measure the radiation dose incurred in the evaluation of vascular filling during transforaminal epidural steroid injections (TFESI) using conventional fluoroscopy (CF), digital subtraction angiography (DSA), and multislice, pulsed computed tomography fluoroscopy (CT/F). METHODS: Three portable C-arms and a fixed multipurpose C-arm were evaluated. The radiation dose rate was measured using an anthropomorphic phantom during CF and DSA in anterior-posterior positions for cervical and lumbar TFESIs. Effective doses were calculated for 5-second exposures. The effective doses incurred in the cervical and lumbar spine during two CT/F exposures were calculated based on the reported volume CT dose index and dose length product. RESULTS: DSA imaging increased the effective dose incurred over CF with portable C-arms (medium dose rate) by 2.5-4.3 fold for cervical TFESI and 2.3-4.2 fold for lumbar TFESI. The incremental dose incurred with DSA ranged from 4.0 to 7.7 µSv in the cervical region and from 22-38 µSv in the lumbar spine. CT/F increased the incurred dose 19-fold in the cervical region and 8.0-fold in the lumbar region (incremental doses 49 µSv and 140 µSv, respectively) relative to CF. CONCLUSION: The use of DSA imaging to exclude vascular uptake during TFESI increases radiation dose over CF. CT/F incurs additional dose beyond most DSA. Minimizing radiation dose by limiting DSA and CT/F use to spine segments or clinical situations involving higher risk may be desirable. However, the incremental radiation doses incurred by DSA or CT/F are of such low magnitude that health risks cannot currently be estimated.


Asunto(s)
Angiografía de Substracción Digital/efectos adversos , Fluoroscopía/efectos adversos , Inyecciones Epidurales/efectos adversos , Dosis de Radiación , Tomografía Computarizada por Rayos X/efectos adversos , Corticoesteroides/administración & dosificación , Humanos , Imagen Multimodal/efectos adversos , Fantasmas de Imagen
20.
Phys Med Biol ; 69(14)2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38942002

RESUMEN

Objective.The use of uniform phantoms to assess the influence of x-ray scatter and antiscatter grids on x-ray angiography and fluoroscopy image quality disregards the influence of spatially variable x-ray attenuation of patients. The purpose of this work was to measure scatter to primary ratio (SPR) and antiscatter grid SNR improvement factor (KSNR) using experimental conditions which better mimic patient imaging conditions.Approach.Three adult-sized anthropomorphic phantoms were used. AP and lateral projection images of the thorax and abdomen were acquired with and without an antiscatter grid. Grids with ratio 15:1 and 29:1 (r15, r29) and x-ray fields of view 20, 25 (thorax) and 32, 42 cm (abdomen) were tested. Combined with a-priori measurements of grid scatter and primary transmission fractions, these images were used to calculate 2D SPR andKSNRmaps.Main results.Results demonstrated that measurements by uniform phantom do not describe the complex 2D SPR andKSNRdistributions associated with anthropomorphic phantoms. The regions of the images with the lowest primary x-ray intensity (greatest attenuation) had the highest SPR and the highestKSNRattributable to the grids. Considering all conditions, the 95th percentile of the SPR maps was in the range 42%-185% greater than the median values and that of theKSNRmaps was 4%-20% higher than the median values. The combined influences of SID 120 vs. 107 cm and r29 vs. r15 grid resulted inKSNRin the range 1.05-1.49.Significance.Performance of anti-scatter grids using anatomically complex phantoms highlights the substantial variation of SPR andKSNRwithin 2D images. Also, this work demonstrates the benefit of the prototype r29 grid for thoracic and abdominal angiography imaging conditions is substantial, especially for large patients and radiodense image regions.


Asunto(s)
Angiografía , Fantasmas de Imagen , Dispersión de Radiación , Humanos , Angiografía/instrumentación , Relación Señal-Ruido , Procesamiento de Imagen Asistido por Computador/métodos